Directional Control Driver for Electric Cylinder

Size: px
Start display at page:

Download "Directional Control Driver for Electric Cylinder"

Transcription

1 Directional Control Driver for Electric Cylinder LCF Series RoHS LEF LEJ LEL LEM LES Product Specifications LCF-5A LCF-5A5 Able to control the stroke with only / signals. Directional control driver like a solenoid valve Able to set thrust arbitrarily. Thrust can be adjusted by adjustment trimmer. Able to control with only different types of input signals. q Directional instruction w Thrust selection e Output / Can be operated manually. Maintenance performance for wiring check has been improved. LEPY LEPS LER LEH -X5 Motorless - LEFS - LEJS 5A- S SS-T Y LAT LZ LCF Model LCF-5A LCF-5A5 Power supply Front side label color Input signal Selction of thrust Ambient temperature Ambient humidity Environment Display LED Weight VDC ± 0% Max.. A Max.. A Gray Blue Photocoupler input VDC ±0% Max. 8 ma/point 00% or set value (Setting range 0 to 70% F.S.) +5 to 0 C 5 to 85% Rh (No condensation) Indoor (Direct sunlight should be avoided.) No corrosive gas, inflammable gas, oil mist or dust particle POWER,,, 5 g 97

2 Directional Control Driver for Electric Cylinder LCF Series RoHS How to Order Option LCF A A5 Power supply 5 VDC Applicable motor DC motor (Cylinder size ) DC motor (Cylinder size 5) 5 A B Housing set (Connector set) A B Housing for CN,, (connector) & contact (connector pin) are included as an accessory. Nothing included. Cable for power supply terminal LCF C 0 Cable type Cable for CN power C supply terminal Cable length 0 0 m m Cable for control terminal LCF C 0 Cable type Cable for CN C control terminal Cable length 0 0 m m Cable for motor output terminal LCF C 0 Cable type Cable length Cable for CN motor C output terminal 0 05 m 5 m Housing set (Connector set) LCF C0 Housing for power supply terminal (Connector) Housing for control terminal (Connector) Housing for motor output terminal (Connector) Contact (Connector pin) 60 ± 5 Cable length 60 ± 5 60 ± 5 Cable length 60 ± 5 CN Control Table COM Common terminal Output Adjusted thrust Traveling direction 60 ± 5 Cable length 60 ± 5 pc. pc. pc. pcs. VHR-N: J.S.T. Mfg Co., Ltd. VHR-N: J.S.T. Mfg Co., Ltd. VHR-N: J.S.T. Mfg Co., Ltd. BVH-T-P.: J.S.T. Mfg Co., Ltd. CN Power Supply Table Do not apply repetitive bending or pulling stress to the cable. Wiring with repetitive bending or pullling stress to the cable will likely cause the cable to break. In the event of crimping the contact (connector pin) and wire, use the specified tools as well as the recommended cable. Crimping tool: YC-60R (J.S.T. Mfg Co., Ltd.) Pulling tool: EJ-NV (J.S.T. Mfg Co., Ltd.) Recommended cable connection (common for individual cable) AWG (0.5 mm ), Insulated wire O.D..7 to.0 mm with shield, Heat resistance is more than 80 C. Maximum cable length CN cable for power supply terminal m CN cable for control terminal m CN cable for motor output terminal 5 m Shield is attached with an optional cable for the LCF series. When grounding a shield, remove the sheath and use a metal U-crip or P-crip. 98 : Motor output : No motor output : Adjusted thrust : 00% thrust (Max. thrust) : (Retracted side) : B-PHASE (Extended side) FG Frame ground DC (+) Driver power supply (+ V) DC ( ) Driver power supply (0 V) Pin number Pin number Optional cable color Yellow/Green Brown Blue Optional cable color White Red Yellow Orange CN Motor Output Table Pin Optional number cable color OUTA Motor output A (Blue) Blue OUTB Motor output B (Red) Red

3 Directional Control Driver for Electric Cylinder LCF Series Applicable Cylinder Table Cylinder part no. L Z - A - L Z 5 - A5 - Applicable directional control driver LCF-5A LCF-5A5 Dimensions How to Mount Mounting 5.5 CN control terminal M x 0.5 For protection grounding terminal mounting x ø.6 For main body mounting Consider the cooling period, so that the operating temperature of main body should be within the range of specifications. Also, allow enough distance from each side of the main body, construction and the parts. Cooling should be considered, so the surface temperature of a heat sink should not be more than 50 C even though the temperature is within the operating range mm (.5) () CN power supply terminal CN motor output terminal Protection grounding terminal Protection grounding terminal related components Cross recessed bind screw M x pc. Spring washer Nominal pc. Tooth lock washer (A) Nominal pc. Related components for mounting the protection grounding terminal are provided together with the product. LEF LEJ LEL LEM LES LEPY LEPS LER LEH -X5 Motorless - LEFS - LEJS 5A- S SS-T Y LAT LZ LCF Mount the directional control driver vertically against the wall, using two mounting screw holes, so the front side (on which its adjustment trimmer and manual switch are located) is facing to an operator. Applicable mounting screw: M ( pcs.) [to be supplied by customer] How to mount a protection grounding terminal Cross recessed bind screw (Accessory) M x.6 Spring washer Nominal (Accessory) Crimping terminal 78.6 Tooth lock washer (A) (Accessory) Nominal Note) Crimping terminal and grounding cable are supplied by customer. x ø.6 99

4 LCF Series Wiring Example Single phase 00 VAC MCCB Noise filter MC MC CN power supply terminal Power supply VDC DC (+) DC ( ) FG LCF Series MCCB : Circuit breaker MC : Contactor Ry : Relay MC Ry Electric cylinder mounted motor Rated input VDC ±0% Max. 8 ma/point Surge suppressor Blue Red CN motor output terminal OUTA OUTB CN control terminal COM Ry Emergency stop signal For System Chart, refer to page 96. Do not short circuit the motor output terminal (CN). Excessive current will flow, and the directional control driver may become damaged. How to wire CN motor output terminal Warning CN power supply terminal There is no emergency stop function or power supply switch in the directional control driver. Please be sure to provide an emergency stop and power supply insulation (insulator) device as a total machine equipment, referencing the above wiring examples. Also, please be sure to turn off the power supply for the whole equipment prior to wiring the directional control driver. CN control terminal Heat sink side CN Power Supply Pin no. FG Frame ground DC (+) Driver power supply (+ V) DC ( ) Driver power supply (0 V) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) CN Motor Output Pin no. OUTA OUTB Motor output A (Blue wire) Motor output B (Red wire) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) 950 Heat sink side CN Control Pin no. COM Output Adjusted thrust Traveling direction Common terminal : Motor output : No motor output : Adjusted thrust : 00% thrust (Max. thrust) : (Retracted side) Note) : B-PHASE (Extended side) Note) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) Note) For the travelling direction (retracted, extended side), refer to the dimensions in pages 90, 9, 96 and 97.

5 Directional Control Driver for Electric Cylinder LCF Series Description of Each Part and its Category Description Details Trimmer Thrust adjustment trimmer POWER Thrust changes through adjustment. Light illuminates when power is supplied. LEF Indicator light Light illuminates by command. (Travelling to the retracted side when illuminated) Light illuminates when turning. (No motor output is generated when illuminated.) LEJ LEL Light illuminates by command. (Thrust set by the thrust adjustment trimmer, when illuminated, will be outputted.) LEM Timing Chart (Extended side) Note) 00% Manual switch command while pressing (Travelling to the retracted side) command while pressing (Motor output will be generated.) command while pressing (Thrust set by the thrust adjustment trimmer will be outputted.) Warning. Do not operate or adjust settings with wet hands. You may experience an electric shock.. When operating the manual switch, make sure that your hands do not come in contact, or is caught between the workpiece. Otherwise you may become injured. CN Control Pin no.. Do not press the manual switch with sharp objects, as the manual switch may be damaged.. Do not touch the directional control driver's heat sink. It will be very hot while turned on, so operate after you have checked that it has become cold.. Adjust the thrust adjustment trimmer under the conditions below. ) Adjust so that the pressure applied to the thrust adjustment trimmer remain below.9 N. ) The adjustment section of the thrust adjustment trimmer should be below 68.6 mn m. COM Output Adjusted thrust Traveling direction Common terminal : Motor output : No motor output : Adjusted thrust : 00% thrust (Max. thrust) : (Retracted side) Note) : B-PHASE (Extended side) Note) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) Note) For the travelling direction (retracted, extended side), refer to the dimensions in pages 90, 9, 96 and 97. LES LEPY LEPS LER LEH -X5 Motorless - LEFS - LEJS 5A- S SS-T Y LAT LZ LCF Thrust 0% (Retracted side) Note) 00% Note) For the travelling direction (retracted, extended side), refer to the dimensions in pages 90, 9, 96 and

6 Directional Control Driver Specific Product Precautions Be sure to read this before handling the products. External force (Manual or spring loaded) Thrust on Design and Operation. If an electric cylinder with DC motor should be rotated by the larger external force than the generated thrust, the reverse inrush voltage generated may cause adverse effects on the electric cylinders directional control driver and result in malfunction or damage to the product. Example) Do not push or pull a cylinder rod, applying a larger load or external force than the generated thrust. (Please use caution if the generated thrust should be switched over between a high thrust and a low thrust.) LCF Do not use this product by stopping it with a load or external force. (control operation) LCF Command an operation in the reverse direction only after a cylinder rod stopped completely. LCF Do not operate a cylinder rod with an external force when the electric cylinder directional control driver is turned off or output is in the off state. (If a cylinder rod needs to be moved manually for the purpose of adjustment, etc., be sure to remove the CN motor output terminal beforehand.) LCF LCF 95

Series. Able to control the stroke with only ON/OFF signals. Directional control driver like a solenoid valve. Able to set thrust arbitrarily.

Series. Able to control the stroke with only ON/OFF signals. Directional control driver like a solenoid valve. Able to set thrust arbitrarily. P099-P0998-E.qxd 0..5 :5 AM Page 99 Directional Control Driver for Electric Cylinder Series LCF LJ LG LCF-5A 첸 LCF-5A5 첸 LTF Able to control the stroke with only / signals. LC Directional control driver

More information

Electric Cylinders. It can be operated like an air cylinder. Directional control driver like a solenoid valve

Electric Cylinders. It can be operated like an air cylinder. Directional control driver like a solenoid valve CAT.ES0-58 B Electric Cylinder Electric Cylinders It can be operated like an air cylinder. Series LZB Series LZC Model LZB LZC Max. thrust Max. speed Lead screw Stroke 196 N 00 mm/s Slide screw: ø8, ø1

More information

Electric Cylinders. It can be operated like an air cylinder. Directional control driver works like a solenoid valve

Electric Cylinders. It can be operated like an air cylinder. Directional control driver works like a solenoid valve CAT.EUS0-58 B -UK Electric Cylinder Electric Cylinders It can be operated like an air cylinder. Series LZB Series LZC Model LZB LZC Max. thrust Max. speed Lead screw (mm) Stroke (mm) 196 N 00 mm/s Slide

More information

240 g. 290 g. Compact and lightweight. Electric Actuators. LEPY/LEPS Series. Miniature Rod Type/Miniature Slide Table Type

240 g. 290 g. Compact and lightweight. Electric Actuators. LEPY/LEPS Series. Miniature Rod Type/Miniature Slide Table Type Electric Actuators LEPY/LEPS Series Miniature Rod Type/Miniature Slide Table Type Compact and lightweight Rod Type LEPY Series Weight 24 g LEPY6-25 3 mm 2.5 mm Slide Table Type LEPS Series Weight 29 g

More information

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40,

More information

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES 76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor

More information

Electric Actuator Series LEL

Electric Actuator Series LEL Electric Actuator Series LEL Guide Rod Slider RoHS LEFS LEFB Low-profile/Flat Height 48 mm Profile reduced by side mounting of motor DOWN LEL25 48 mm Max. stroke: 1 mm Transfer speed: 1 mm/s LEFB25 115.8

More information

LZB/LZC. Series LZB LZC. Electric Cylinder. Series. Series LJ1 LG1 LTF LC1 LC7 LC8 LXF LXP LXS LC3F2 E-MY LZB LZC

LZB/LZC. Series LZB LZC. Electric Cylinder. Series. Series LJ1 LG1 LTF LC1 LC7 LC8 LXF LXP LXS LC3F2 E-MY LZB LZC P097-P0992-E.qxd..1 11:3 AM Page 97 Electric Cylinder Series LZB/LZC. r e d n yli e k i l d te It can LJ1 c r i a an LG1 LTF ra e p o be LC1 LC7 LC8 LXF Series LXP LZB LXS LC6첸 LZ첸 LC3F2 X첸 Series D-첸

More information

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information MEMS Air Velocity Sensor Compact, intelligent sensors featuring MEMS precision technology for repeatable airflow detection. Precision uni-directional air velocity detection. Integral passive Dust Segregation

More information

Electric Actuator/ Guide Rod Type

Electric Actuator/ Guide Rod Type ourtesy of M/Flodyne/Hydradyne Motion ontrol Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Size How to Order LEYG M B 50 S N1 Bearing type M Sliding bearing L Ball bushing bearing

More information

AC Servo Motor Driver Series LECS

AC Servo Motor Driver Series LECS AC Servo Motor Driver Series LECS Pulse Input Type/ Positioning Type Page 64 Incremental Type/ Series LECSA Pulse Input Type Page 64 Absolute Type/ Series LECSB CC-Link Direct Input Type Page 64 SSCNET

More information

Series LECSB. Series LECSA. Series LECSC. Series LECSS. AC Servo Motor Driver. Pulse Input Type. Pulse Input Type/ Positioning Type.

Series LECSB. Series LECSA. Series LECSC. Series LECSS. AC Servo Motor Driver. Pulse Input Type. Pulse Input Type/ Positioning Type. AC Servo Motor Driver Series LECS Pulse Input Type/ Positioning Type Pulse Input Type Incremental Type Series LECSA LEF AbsoIute Type Series LECSB CC-Link Direct Input Type SSCNET # Type Absolute Type

More information

Basic and high precision types are available.

Basic and high precision types are available. Series RoHS Model H 1 3 5 42 Rotation angle: 36 Page 47 LEJS LEJB type [mm] Continuous rotation specification LEL Low profile LEFS LEFB 53 68 H 49 LEY LEYG Model H1 H3 H5 LEM High precision type [mm] 62

More information

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature MEMS Mass Flow Sensor D6F-P A Compact, High-performance Flow Sensor with Dust Segregation Structure. Built in Dust Segregation System (DSS) with cyclone flow structure, diverts particulates from sensor

More information

Space-saving installation Flexible motor mounting

Space-saving installation Flexible motor mounting Space-saving installation Flexible motor mounting compatible!! Pulse train input compatible Automatic actuator recognition Addition of new controller compatible with pulse trains Enables current position

More information

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features

More information

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil Ionizer / with surface potential sensor Series IZS0 How to Order 00 0 00 00 Ionizer IZ S 0 0 Bar length Bar length 00 mm 0 mm mm 00 mm 00 mm Ionizer Made to Order Bar type Size Electrode needle material

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

HWS 15A-150A Series. Instruction Manual

HWS 15A-150A Series. Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

ZWD100PAF. Conformity to RoHS Directive

ZWD100PAF. Conformity to RoHS Directive -SERIES Dual Output W - 225W Features 15 Complies the standard of the harmonics current limiter Worldwide input: 85-265VAC Peak load accommodatable double power: Approximately twice the value of average

More information

Electric Actuator Controller/Driver

Electric Actuator Controller/Driver Slider Series LEF Electric Actuator Controller/Driver Slider /High Rigidity Series LEJ Guide Rod Slider Series LEL P.1 P.2 P.3 Slider / Low Profile Series LEM Rod Series LEY Slide Table Series LES P.4

More information

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series. PRODUCT NEWS Correction Reissue Product Discontinuation Notices Proximity Sensors Issue Date August 4, 2014 No. 2014038CE(3) Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _ Diameter mm Shaft Type/Hollow Type/Built-In Type Incremental Rotary Encoder Features Diameter mm flange type Suitable for measuring angle, position, revolution, speed, acceleration and distance Power supply:

More information

ZWD100PAF Series Instruction Manual

ZWD100PAF Series Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

ZWD225PAF Series Instruction Manual

ZWD225PAF Series Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global 3 Adjustable Range Reflective Photoelectric SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.549~ guide... P.3~ General precautions... P.55~ PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations Solid State Relays G3RV Slimmest OMRON plug-in SSR with maximum width 6.2 mm Long electrical life and high speed switching Large plug-in terminals for reliable connection G3RV-D (DC load) models can manage

More information

AZ Series Motor OPERATING MANUAL. Introduction. Safety precautions. CE Marking

AZ Series Motor OPERATING MANUAL. Introduction. Safety precautions. CE Marking HM-6244-3 OPERATING MANUAL Closed Loop Stepping and Driver Package AZ Series Introduction Before use Only qualified personnel should work with the product. Use the product correctly after thoroughly reading

More information

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER THT-500-A/R No.THT51E1 2017.12 Thank you for purchasing our THT-500-A/R, Temperature and Humidity Transmitter (mounted within control panel). This

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

/ LOSSNAY / LGH-RS2-E2

/ LOSSNAY / LGH-RS2-E2 2 Indoor units / / LGH-RS2-E2 unit CONTENTS LGH-RS2-E2. LGH-5RS2-E2 48 2. LGH-25RS2-E2 49. LGH-5RS2-E2 44 4. LGH-5RS2-E2 44 5. LGH-8RS2-E2 442 6. LGH-RS2-E2 7. LGH-5RS2-E2 8. LGH-2RS2-E2 44 444 445 9.

More information

240 g. 290 g. Electric Actuators Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type

240 g. 290 g. Electric Actuators Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type Electric Actuators Series / Miniature Rod Type/Miniature Slide Table Type RoHS Compact and lightweight Rod Type Series Weight 24 g 6-25 Maximum pushing force: 5 N Positioning repeatability:.5 mm Possible

More information

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in) 817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global

More information

240 g. 290 g. Electric Actuators. Compact and lightweight. New. Series LEPY/LEPS. Offering 2 types of controller

240 g. 290 g. Electric Actuators. Compact and lightweight. New. Series LEPY/LEPS. Offering 2 types of controller Electric Actuators Miniature Rod Type Compact and lightweight Rod Type Series LEPY Miniature Slide Table Type RoHS Maximum pushing force: N Positioning repeatability:. mm Possible to set position, speed

More information

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION Sensor INSTRUCTI MANUAL Head Separated Digital Sensor Controller DPC-1 Series MJE-DPC1 No.7-98V Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly

More information

AC Servo Motor Driver

AC Servo Motor Driver AC Servo Motor Driver Series Pulse Input Type/ Positioning Type Page 613 Incremental Type/ SA Series Absolute Type/ SC Series Pulse Input Type Page 613 Absolute Type/ SB Series CC-Link Direct Input Type

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force. Tactile Switch A Wide Range of Models: 6 x 6 mm, 1 x 1 mm, Vertical, and High-force. A positive click action plus a long life equal to that of a no-contact switch. Radial models (taping specifications)

More information

240 g. 290 g. Compact and lightweight. Electric Actuators. Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type

240 g. 290 g. Compact and lightweight. Electric Actuators. Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type Electric ctuators Series LEPY/LEPS Miniature Rod Type/Miniature Slide Table Type Step Motor (Servo/2 VDC) and lightweight Rod Type Series LEPY Weight 2 g LEPY6-2 RoHS Maximum pushing force: N Positioning

More information

Filterpack FR-BFP2-(H)0.4K to (H)15K

Filterpack FR-BFP2-(H)0.4K to (H)15K INVERTER INSTRUCTION MANUAL FR-BFP2-(H)0.4K to (H)15K 1. Product Checking... 1 2. Applicable Inverter... 1 3. Installation... 2 3.1 Inverter Installation (installation of the )...2 4. Wiring... 4 5. Main

More information

General-Purpose AC Servo MELSERVO-J4 Series Power Regeneration Converter Unit MR-CV_ SSCNET III/H Compatible Drive Unit MR-J4-DU_B_(-RJ)

General-Purpose AC Servo MELSERVO-J4 Series Power Regeneration Converter Unit MR-CV_ SSCNET III/H Compatible Drive Unit MR-J4-DU_B_(-RJ) General-Purpose AC Servo MELSERVO-J4 Series Power Regeneration Converter Unit MR-CV_ SSCNET III/H Compatible Drive Unit MR-J4-DU_B_(-RJ) January, 2017 New Product Release SV1701-3E 3-phase power supply

More information

Hour Meter Series HM36

Hour Meter Series HM36 Robust design with high degree of Accuracy and Compact size Frequency independent for AC applications Indicates operating time in hours and tenths with running indicators Totally sealed from Dust and Moisture

More information

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual DC power supply connect to VF-AS1/PS1 Optional initial charger Instruction manual NOTE 1. Make sure that this instruction manual is delivered to the end user of the optional initial charger. 2. Read this

More information

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase) SRPH1 Series Single Phase, Analog Input Type SSR Features Power control/ Cycle control/phase control (fixed cycle/ variable cycle) are available with 4-mA analog input Superior dielectric strength : 4,000VAC

More information

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations SERIES Digital Sensor Digital Automatic sensitivity setting Auto reference With analog output /, sec. The fastest response in the industry DP DP Conforming to EMC Directive UL Recognition Super fast ms

More information

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000

More information

56 mm sq. (2.20 inch sq.)

56 mm sq. (2.20 inch sq.) 56 mm sq. (2.2 inch sq.) 1.8 /step RoHS Bipolar winding, Lead wire type Unipolar winding, Lead wire type p. 68 Customizing Hollow Shaft modification Decelerator Encoder Varies depending on the model number

More information

Figure 1: WPR2 Dimensions and Hardware

Figure 1: WPR2 Dimensions and Hardware Installation and Operation Instructions WPR2 Series (Max. Line Pressure < 300 PSI) Wet to Wet Differential Pressure Ø0.200" 2.60" 4.47" 5.47" 5.28" 3.00" Precautions Figure 1: WPR2 Dimensions and Hardware

More information

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g. Tactile Switch BW Tactile Switch with Sealed Construction for Automatic Soldering Sealed construction conforming to IP67 (IEC-6059) provides high reliability in locations exposed to dust or water. Available

More information

High-power Solid State Relays G3PH

High-power Solid State Relays G3PH New Product News High-power Solid State Relays G3PH High-power, Load-control s with High Current of 75 or 150 A and High Voltage of 240 or 480 VAC RoHS compliant. Models also available with no zero cross.

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

AC/DC2-wire Type Cylindrical Proximity Switches

AC/DC2-wire Type Cylindrical Proximity Switches AC/DC2-wire Type Cylindrical Proximity Switches FL7M Series No-polarity 2-wire general-purpose switches are easy to use. 2-wire type for both AC and DC greatly reduces wiring man-hours Stable sensing area

More information

CX-SERIES ADVANCED BATTERY CHARGER

CX-SERIES ADVANCED BATTERY CHARGER CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...

More information

Safety Precautions. Safety Precautions for

Safety Precautions. Safety Precautions for E5@N in this catalog have been discontinued at the end of March 2017. Safety Precautions for E5@N/E5@N-H/E5@N-HT Safety Precautions for E5@N/E5@N-H/E5@N-HT Safety Precautions Refer to Safety Precautions

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com EMUJC Series Electronic actuator Technical Data Sheet WattsIndustries.com Description Watts Water Technologies, Inc. The actuator EMUJC Series is an electronic device with 3-point or proportional control

More information

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use HM-08 OPERATING MANUAL Stepping motor and driver package High-efficiency AR Series DC power input Built-in Controller Type (RS-8 communication function) Driver Introduction Before use Only qualified personnel

More information

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output. Solid State Relay G3NA New Models with 75-A and 9-A Output Join the Previous Models with 5- to 5-A Output. AC Output Relays with 75-A and 9-A output added. All models feature a uniform mounting pitch.

More information

240 g. 290 g. Electric Actuators. Compact and lightweight. New. Series LEPY/LEPS. Offering 2 types of controller

240 g. 290 g. Electric Actuators. Compact and lightweight. New. Series LEPY/LEPS. Offering 2 types of controller Electric Actuators Miniature Rod Type Compact and lightweight Rod Type Series LEPY Miniature Slide Table Type New RoHS Maximum pushing force: N Positioning repeatability: ±. mm Possible to set position,

More information

Electric Actuators. New. Motorless Type. Series LE. Your motor and driver can be used together! Manufacturers of compatible motors: 8 companies

Electric Actuators. New. Motorless Type. Series LE. Your motor and driver can be used together! Manufacturers of compatible motors: 8 companies Motorless Type Electric Actuators New RoHS Your motor and driver can be used together! Manufacturers of compatible motors: companies Mitsubishi Electric Corporation SANYO DENKI CO., LTD. Panasonic Corporation

More information

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal

More information

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE 6 FL7M-A Series FEATURES Workpieces Reliably Sensed Even if Aluminum or Cast Iron Chips Accumulate on the Sensing Head. This DC 2-wire type proximity sensor can be directly connected to programmable controllers

More information

Model Number Structure

Model Number Structure Conductive Level Controller CSM DS_E_1_1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at or using self-holding circuits. Sensitivity adjustment of operating

More information

Helical Flow. HF-GC/GP Series

Helical Flow. HF-GC/GP Series Helical Flow A Helical Flow Type of Screw Revolution Instruction Manual for HF-GC/GP Series (SC and MP/MC Series incld. ) Caution Before use, please read this Instruction Manual thoroughly for safe operation.

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

LJ1H LEJS40 AC

LJ1H LEJS40 AC Low-profile/Low center of gravity Height dimension reduced by approx. 36% (Reduced by 32 mm) 9 Electric Actuator LEJ Series Slider Type/High Rigidity 58 (Former model) LJ1H2 3 5 1 LJ1H2 LEJS4 RoHS Series

More information

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor. Ionizer 2 types of sensors are available. Rapid elimination of static electricity by a feedback sensor Continuously emits ions in accordance with the detected polarity of a workpiece. Supply pressure:

More information

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G3RV The World's First Industrial Slim Relay G2RV compatible LED indicator built in SSR Push-in terminals and accessories for easy wiring. Model Number Structure Model Number Legend G3RV-SL

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Electric Actuator/ Rod Type

Electric Actuator/ Rod Type How to Order LEY B 30 S N1 Lead Symbol LEY LEY LEY/ 10 12 B 5 6 8 2.5 3 4 otor option Nil Without option With motor cover B With lock W With lock/motor cover When With lock or With lock/motor cover are

More information

ABL Series. Relay Terminal Block (Screwless Type) Features

ABL Series. Relay Terminal Block (Screwless Type) Features ABL Series Relay Terminal Block (Screwless Type) Features Input (NPN, PNP common) and Output (Independent, Common) Selection with Jumper Bars Allows switching between NPN common and PNP common inputs by

More information

E2K-L. Liquid Level Sensor. Applications. Ordering Information

E2K-L. Liquid Level Sensor. Applications. Ordering Information Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

High-power Solid State Relays G3PH

High-power Solid State Relays G3PH New Product News High-power Solid State Relays G3PH High-power, Load-control s with High Current of 75 or 150 A and High Voltage of 240 or 480 VAC RoHS compliant. Models also available with no zero cross.

More information

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC Solid State Relays G3NB with 40-A output at a reasonable price. Switches 9 A without a heat sink. Zero cross function enables less noise operation. Built-in varistor effectively absorbs external surges.

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Solenoid coil for control in potentially explosive areas Type BZ

Solenoid coil for control in potentially explosive areas Type BZ Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used

More information

ZWS-BAF Series. Instruction Manual. TDK-Lambda. ZWS-BAF Series Instruction Manual A H

ZWS-BAF Series. Instruction Manual. TDK-Lambda. ZWS-BAF Series Instruction Manual A H BEFORE USING THE POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. Incorrect usage could

More information

2-PHASE STEPPING SYSTEMS. Ver.6.1

2-PHASE STEPPING SYSTEMS. Ver.6.1 -PHASE STEPPING SYSTEMS Ver.. AC Input Set Models AC Input DC Input Set Models DC Input Stepping Motors Stepping Motors, IP Splash and Dust Proof Stepping Motors, Stepping Motors for Vacuum Environments,

More information

Plug Lead Unit: Flip Type

Plug Lead Unit: Flip Type Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

2-PHASE STEPPING SYSTEMS. Ver.5

2-PHASE STEPPING SYSTEMS. Ver.5 -PHASE STEPPING SYSTEMS Ver. DC Input Set Models DC Input Drivers Stepping Motors Motor size: mm sq. (. inch sq.) to mm sq. (. inch sq.), mm (. inch) Stepping Motors with Integrated Drivers IP Splash and

More information

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES Head Separated Digital Pressure Sensor SERIES /000 Second High-Speed Response Conforming to EMC Directive UL Recognition /,000 sec. The advantage of the fastest response in the industry 55 High speed in

More information

ROBOT CONTROLLER / Drive Unit RC700DU / RC700DU-A

ROBOT CONTROLLER / Drive Unit RC700DU / RC700DU-A ROBOT CONTROLLER / Drive Unit RC700DU / RC700DU-A Rev.8 EM16XC3313F ii ROBOT CONTROLLER / Drive Unit RC700DU / RC700DU-A Rev.8 ROBOT CONTROLLER / DRIVE UNIT RC700DU / RC700DU-A Rev.8 Copyright 2014-2016

More information

POWER-WIN TECHNOLOGY CORP.

POWER-WIN TECHNOLOGY CORP. atts Dual to Quad Output FEATURES Build-in active PFC function, PF > 0.9 Compact design for multiple outputs Dual to Quad output, Flexible DC output combination from 3.3V to 48V 2 year warranty ELECTRICAL

More information

Limit Switch A. Dog a

Limit Switch A. Dog a inear and Rotary Actuators RoHS-Compliant Rack and Pinion Systems S inear Heads Additional Information Technical reference Page F-1 2S 4S Vertical Stroke: F Type Horizontal Stroke: B Type Vertical Stroke:

More information

Vacuum Ejector. Adaptable for manifold application

Vacuum Ejector. Adaptable for manifold application Vacuum Ejector Series ZM ZX All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum Vacuum release valve (equipped with a flow volume adjustment valve) Vacuum pressure

More information

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems CDBR-B Dynamic Braking Unit Instruction Manual April 2009 Part Number: 146-10001-R1 Copyright 2009 Electromotive Systems 2009 MAGNETEK All rights reserved. This notice applies to all copyrighted materials

More information

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c Series Single phase, Analog input type SSR Features Power control/ Cycle control/phase control (fixed cycle/ variable cycle) are available with 4-mA analog input Superior dielectric strength : 4,000VAC

More information

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type) CAT.1101E-S www.sym1.com KV series Innovatively detachable Manifold Block (DIN Rail Mounting) Smart Solenoid Valve (Plug-in type, D-SUB multi-connector ) Compact size with large flow capacity Exceedingly

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Your motor and driver can be used together! Manufacturers of compatible motors: 8 companies. Ball screw drive. Series LEJS. Size

Your motor and driver can be used together! Manufacturers of compatible motors: 8 companies. Ball screw drive. Series LEJS. Size Motorless Type Electric Actuators New RoHS Your motor and driver can be used together! Manufacturers of compatible motors: companies Mitsubishi Electric Corporation SANYO DENKI CO., LTD. Panasonic Corporation

More information

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C.

DC2-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors N.O. N.C. N.O. N.C. N.O. N.C. 8mm N.O. N.C. N.O. N.O. N.C. N.O. N.O. N.C. DC-Wire Aluminum-Chip Resistant Cylindrical Proximity Sensors FL7M-ASeries Detects workpieces reliably even if aluminum or cast iron chips accumulate on the sensing head. DC-wire proximity sensors can

More information

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1 No.EX -OME0016-A PRODUCT NAME SI unit MODEL / Series / Product Number EX140-SDN1 Table of Contents 1. Safety instructions 2 2. Specifications 7 2-1. General specifications 7 2-2. Electrical ant network

More information

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4 Braking Resistor Units 3G3IV-PCDBR2 B/4 B Braking Units Thank you for choosing an OMRON Braking Resistor Unit and Braking Unit. Proper use and handling

More information