1 Pressure Gauge for General Purpose Series G5/G27 G5 G27 G5-0-0 G27-0- Be sure to read the precautions on page 663 for selection and mounting. Dimensions Port size () precision ±5% F.S. (Full span) Case Zinc die-casted (Black graphite coated) Material Polycarbonate Stud Zinc die-casted (Black graphite coated) Bourdon tube Mass (kg) Caution on handling: When drain or oil, etc. gets into the gauge, it may result in a malfunction. ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product to be damaged. Use a pipe tape for sealing. ecommended tightening torque is between 3 and N m for /6 and 7 and 9 N m for /8. 2) Water cannot be used as an operating fluid. Because the clearance gap of the air passage of the Bourdon tube is very small. Water will block the gap and cause a malfunction. Similarly, when using other fluids, please consult with SMC for fluid compatibility information concerning possible corrosion and response delay, etc. (Standard) (Made to Order) G5 Back side : M5 (Female ) G27 G5-0-0 (2) G27-0- /8, M5 (Female ) 6 ) Do not apply more excessive pressure than max. pressure display. It will be a cause of malfunction. 2) Display : single compatible G27-0-M5-X20 G27-P0--X30 Other versions of this can be made on a made-to-order basis. Please consult with SMC for details, as delivery times may be extended. 8 6 psi 0 to 50, psi M5 (Female ) 6 ) Do not apply more excessive pressure than max. pressure display. It will be a cause of malfunction. G 2 (Width across flats) G Pressure Size gauge 0 () /8: M5 (Female ) Size /6 ) Both /8 and M5 (female Outside diameter ) in case of G5 type 5 ø5 2) Compatible with G27 type only 27 ø26 Max. display pressure 0 ().0 P0 () (2) Unit.0, 50 psi ) Pressure other than.0 is not available. 2) This symbol must be used with X30. X30 X20 Specifications Both and psi M5 (Female ) only ) X3 (Wetted parts SUS) specifications are not available. 65

2 Pressure Gauge for General Purpose/ With Limit Indicator Series G36/GA36 G Be sure to read the precautions on page 663 for selection and mounting. Port size () precision Material Case Stud Bourdon tube G36 Back side 8 ±3% F.S. (Full span) Aluminum die-casted (Black disulfide molybdenum coat treated) Aluminum die-casted (Black disulfide molybdenum coat treated) GA36 Vertical side ( M: With M5 female ) olled steel (Black melamine painted) Polycarbonate (Part no.: G ) Mass (kg) ) When installing a pressure gauge, be careful not to fasten too tight. Excessive tightening will result in damage. Use a pipe tape for sealing. ecommended tightening torque is 8 : Set between 7 and 9 N m. 2) Not applicable to water as fluid because its stub is made from aluminum die-casted. Water may cause corrosion and block the air passage. Use a pressure gauge with wetted parts made from stainless steel, G6- -X3. (: Take care when using G36- -0M, whose wetted part is made from brass. Some corrosion may result.) Design system to not be affected by water hammer when using water as fluid. Similarly, when using other fluids, please consult with SMC, to prevent corrosion-related problems. (Standard) G G36--0 G G GA (Made to Order) G X2 G36-P2-0-X30 G36-P0-0-X30 G to.5 psi 0 to 30 0 to 50 8 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. Other versions of this can be made on a made-to-order basis. Please consult with SMC for details, as delivery times may be extended., psi 8 Plated stem (Ni) ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. 66

3 Pressure Gauge for General Purpose/With Limit Indicator Series G36/GA36 G A Pressure gauge Size Outside diameter 36 ø37.5 Back side Vertical side Specifications Size M 0 M5 (Female ) 8 ) Use M5 female when piping onto a panel. Max. display pressure P2 ) P0 ) Unit , 30 psi.0, 50 psi ) This symbol must be used with X30. X2 X X30 Specifications Nickel plated Oil-free Wetted parts degrease washing Both and psi ) X3 (wetted parts stainless steel) specifications is not available. 2) Cover ring assembly is not available. G Dimensions G36 GA36 67

4 Pressure Gauge for General Purpose/ With Limit Indicator Series G6/GA6 G6-0-02M-C Be sure to read the precautions on page 663 for selection and mounting. Port size () precision Material Case Stud Bourdon tube Attachment: With cover ring assembly C C G6 Back side Part no.: 3050-A Part no.: A GA6 Vertical side /8, / ( M: with M5 female ) ±3% F.S. (Full span) Aluminum die-casted (Black disulfide molybdenum coated) Aluminum die-casted (Black disulfide molybdenum coated olled steel (Black melamine painted) Polycarbonate (Part no.: G ) Mass (kg) ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product to be damaged. Use a pipe tape for sealing. ecommended tightening torque: /8: Set between 7 and 9 N m, /: 2 and N m respectively. 2) Not applicable to water as fluid because its stub is made from aluminum die-casting. Water may cause corrosion and block the air passage. Use G6- -X3 pressure gauge with wetted parts stainless steel (wetted parts of G6- -0M are made of brass and this become lightly corroded. Take precautions when using.) Design system to not be affected by water hammer when using water as fluid. Similarly, when using other fluids, please consult SMC for fluid compatibility information concerning corrosive potential. (Standard) G6-2-0/02 G6--0/02 G6-7-0/02 G6-0-0/02 G6-2-0 to 02M G6--0 to 02M G6-7-0 to 02M G6-0-0 to 02M GA6-0-0 to 02 8, 8, M5 (Female ) 8, ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. (Made to Order) G6-2-0 to 02-C/C G6--0 to 02-C/C G6-7-0 to 02-C/C G6-0-0 to 02-C/C G6-2-0 to 02M-C/C G6--0 to 02M-C/C G6-7-0 to 02M-C/C G6-0-0 to 02M-C/C G6-P2-0 to 02-X30 G6-P0-0 to 02-X30 G6-2-02M-X G6--02M-X G6-7-02M-X G6-0-02M-X G6-2-02M-C/C-X G6--02M-C/C-X G6-7-02M-C/C-X G6-0-02M-C/C-X G6-P2-0 to 02-C-X30 G6-P0-0 to 02-C-X30 G X2 G6-5-0 to 02 psi 0 to.5 Other versions of this can be made on a made-to-order basis. Please consult with SMC for details, as delivery times may be extended. 0 to 30 0 to 50 0 to 30 0 to 50. psi, psi 8, 8, M5 (Female ) 8, 8, ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. With cover ring assembly Oil-free M5 (Female ) Oil-free, With cover ring assembly With cover ring assembly Plated stem (Ni) 68

5 Pressure Gauge for General Purpose/With Limit Indicator Series G6/GA6 G Pressure gauge Specifications Back side Size M With M5 (Female ) A Vertical side Size Outside diameter 6 ø ) Use M5 female when piping onto a panel. Max. display pressure Unit P2 ) 0.2, 30 psi P0 ).0, 50 psi ) This symbol must be used with X30. Attachment Specifications Without cover ring assembly C ) has no protrusion. ( is irremovable.) has protrusion. C ) ( is removable.) ) Compatible with G6 type only X2 X3 () (2) X X30 Specifications Stud parts Nickel plated Wetted parts stainless steel () Wetted parts Oil-free degrease washing Both and psi ) Movable parts (gear, etc) inside pressure gauge are made of brass. 2) Compatible with G6 type only G Dimensions The dimensions in ( ): Connecting / G6 G6: With cover ring assembly (For panel mount) Panel cut dimensions Plate thickness Max. 3.5t C ( is not removable.) C ( is removable.) 3.5 (5.5) 3.5 (5.5) 5 GA6 For setting method, refer to page

6 Pressure Gauge for General Purpose Series G33/GA33 Be sure to read the precautions on page 663 for selection and mounting. Dimensions G33 GA ø30 /8 ø30 0 Hex. width across flats ø3 Bleed port (7) 3 G GA /8 28 Port size () precision Case Material Stud Bourdon tube Applicable model (Standard) G G G to 0.3 G to 0.6 G GA GA33--0 GA GA ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. (Made to Order) G X2 G X2 G33--0-X2 G X2 G X2 GA X2 GA33--0-X2 GA X2 GA X2 G X GA33-P0-0-X30 G33 Back side psi 0 to to to 50 GA33 Vertical side 8 ±3% F.S. (Full span) Stainless steel Glass IP5000, IP6000, I000, IT000, AM2500, 3000 ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product to be damaged. Use a pipe tape for sealing. ecommended tightening torque: /8: Set between 7 and 9 N m. 2) When using other fluids, please consult with SMC for fluid compatibility information concerning corrosive potential. 8 X2: Stud parts electroless nickel plated X2: Stud parts nickel plated X: Oil-free (Wetted parts degreasing), psi 8 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G Pressure Size gauge 0 8 Frame type Max. display pressure Outside diameter Back side 33 ø30 Vertical side A ) This symbol must be used with X30. 2) Compatible with GA33 type only P0 () (2) Unit , 50 psi Specifications X2 Stud parts electroless nickel plated Wetted parts X Oil-free degrease washing X30 Both and psi ) X3 (Wetted parts stainless steel) specifications is not available. 2) Please contact SMC separately for pressure range of GA33 between 0 and 0.6.

7 Pressure Gauge for General Purpose Series G3 G3-0-0 Be sure to read the precautions on page 663 for selection and mounting. External Dimensions (Except made-to-order products) ø3 Bleed port The dimensions in ( ): Connecting Port size () precision Case Material Stud Bourdon tube Applicable model (Standard) G3-2-0 to 02 G3--0 to 02 G3-6-0 G3-7-0 to 02 G3-0-0 to 02 (Made to Order) 0 to 0.6 G3 Back side 8, ±3% F.S. (Full span) Stainless steel Glass IP200, IP8000, I2000, I3000, IT2000, 000 ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product to be damaged.use a pipe tape for sealing. ecommended tightening torque: /8: Set between 7 and 9 N m, /: 2 and N m respectively. 2) When using with water, use G3- -X3 (wetted parts stainless steel) and use caution not to apply water hammer. When using the other fluids, please consult with SMC for fluid compatibility information concerning corrosive potential. ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G3-2-0 to 02-X2 8, G3--0 to 02-X2 X2: Stud parts G3-6-0-X2 0 to nickle plated G3-7-0 to 02-X2 8, G3-0-0 to 02-X2 G3-2-0 to 02-X3 8, G3--0 to 02-X3 X3: Wetted parts G3-6-0-X3 0 to stainless steel G3-7-0 to 02-X3 8, G3-0-0 to 02-X3 G3-2-0 to 02-X 8, G3--0 to 02-X X: Oil-free G3-6-0-X 0 to (Wetted parts G3-7-0 to 02-X degreasing) 8, G3-0-0 to 02-X ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G3 0 0 Pressure gauge 3 ø3 Outside diameter Max. display pressure Unit: size Size , 8 8, X2 X3 X Specifications Stud parts nickel plated Wetted parts stainless steel Oil-free (Wetted parts degrease washing) 65 G

8 Pressure Gauge with Limit Indicator/ Color Zone Series G36-L/G6-L ed and green zones offer improved visibility of pressure control range. Green indicator G L G L Indicator adjusts to highlight preferred range. ed indicator Port size () precision Material Mass (kg) G36-L G6-L Case Stud Bourdon tube Back side /8 /8, / Polycarbonate (Part no.: G ) Nylon (Part no.: G N) ±3% F.S. (Full span) (3) olled steel (Black melamine painted) ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product to be damaged. Use a pipe tape for sealing. ecommended tightening torque: /8: Set between 7 and 9 N m, /: 2 and N m respectively. 2) When using other fluids, please consult with SMC for fluid compatibility information concerning corrosive potential. 3) Temperature conditions: at 20 C (±5 C), in other cases, ±6 C F.S. Polycarbonate (Part no.: G ) Nylon (Part no.: G N) (Standard) Green zone setting range Minimum setting range () Maximum setting range () G L G36--0-L G L G6-2-0 to 02-L G6--0 to 02-L G6-0-0 to 02-L /8 /8, / ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. (Made to Order) psi Green zone setting range Minimum setting range ( (psi)) Maximum setting range ( (psi)) G36-P2-0-L -X30 G36-P-0-L -X30 G36-P0-0-L -X30 G6-P2-0 to 02-L -X30 G6-P-0 to 02-L -X30 G6-P0-0 to 02-L -X30 0 to 30 0 to 60 0 to 50 0 to 30 0 to 60 0 to (2) 0.02 () 0.05 (0) 0.0 (2) 0.02 () 0.05 (0) 0. () 0.2 (28) 0.5 (70) 0. () 0.2 (28) 0.5 (70), psi /8 /8, / ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. 652

9 Pressure Gauge with Limit Indicator/ Color Zone Series G36-L/G6-L G L 36 6 Size Outside diameter ø37.5 ø2.5 Made to Order Specifications X30 Both and psi Max. display pressure Unit P2 ) 0.2, 30 psi P ) 0., 60 psi P0 ).0, 50 psi ) This symbol must be used with X30. material Material Polycarbonate N Nylon Color zone type Thread port size Port Applicable size G36 G6 0 /8 02 / G Dimensions G36 Green zone ed zone ø /8 ed zone Polycarbonate part no.: G Nylon part no.: G N G6 Green zone ed zone.5 (5.5) 25.5 ø2.5 2 ( ) /8 ( /) ed zone Polycarbonate part no.: G Nylon part no.: G N ( ): / 653

10 Oil-free/External Parts Copper-free Pressure Gauge/With Limit Indicator Series G6E G6E-0-02M G6E-0-02M-C Port size () precision Fluid contact part cleaning Case G6E Back side 8, ( M: with M5 female ) ±3% F.S. (Full span) Wetted parts degrease washing olled steel (Black melamine painted) Be sure to read the precautions on page 663 for selection and mounting. Dimensions G6E G6E: With cover ring assembly (For panel mounting) C ( is not removable.) C ( is removable.) 5 Dimensions in ( ): / connecting Panel cut dimensions Plate thickness Max. 3.5 t Material Stud Polycarbonate (Hard coated) Part no.: G (Electroless nickel plated) Bourdon tube (3) Mass (kg) 0.08 Attachment: C Part no.: 3050-A With cover ring assembly C Part no.: A ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product failure. Use a pipe tape for sealing. ecommended tightening torque: 8 : Set between 7 and 9 N m, : 2 and N m respectively. 2) When fluid is water, use G6- -X3. Wetted parts are made of stainless steel construction. (Some corrosion may be caused by water because this product's wetted parts are made of brass.) Design system to not be affected by water hammer when using water as fluid. Similarly, when using other fluids, please consult with SMC for fluid compatibility information concerning corrosive potential. 3) Bourdon tube and internal movable parts (gear, etc.) are made of brass and are not electrolessly nickel plated. This is not an internally copper-free product. (Standard) G6E-2-0 to 02M G6E--0 to 02M G6E-7-0 to 02M G6E-0-0 to 02M 8 M5 (Female ) ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. (Made to Order) G6E-2-0 to 02M-C, C G6E--0 to 02M-C, C G6E-7-0 to 02M-C, C G6E-0-0 to 02M-C, C G6-P2-0 to 02M-C, C-X30 G6-P0-0 to 02M-C, C-X30 Other versions of this can be made on a made-to-order basis. Please consult SMC for details, as delivery times may be extended. psi 0 to 30 0 to 50, psi 8 M5 (Female ) With cover ring assembly ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. For mounting method, refer to page

11 Oil-free/External Parts Copper-free Pressure Gauge/ With Limit Indicator Series G6E G 6 E 0 0 Pressure gauge Size Outside diameter 6 ø2.5 X30 Specifications Both and psi E Specifications Specifications Oil-free, external parts copper-free Max. display pressure Unit P2 ) 0.2, 30 psi P0 ).0, 50 psi ) This symbol must be used with X30. Attachment Specifications Without cover ring assembly has no protrusion. C ( is irremovable.) has protrusion. C ( is removable.) Specifications M With M5 (Female ) ) Use M5 female when piping onto a panel. G Size

12 Pressure Gauge for Clean Series (0-series) Series G9 Be sure to read the precautions on page 663 for selection and mounting. Dimensions ø / Installation of a filter on the breathing hole (filtration 3 μm) enables an to curb particle generation from the pressure gauge inside. G9 Back side Port size () precision ±3% F.S. (Full span) Case Zinc die-casted (Chromate plated) Glass Material Stud (Nickle plated for external parts only) Bourdon tube (3) Mass (kg) ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product failure. Use a pipe tape for sealing. ecommended tightening torque: Set between 2 and N m. 2) When fluid is water, use G9- -X3. Wetted parts of G9- -X3 are made of Stainless steel. Use caution as some corrosion may be caused by water. Standard G9 pressure gauge conact area is made of brass. When using water, use caution not to apply water hammer. Similarly, when using other fluids, consult SMC for fluid compatibility information concerning corrosive potential. 3) Bourdon tube and internal movable parts (gear, etc.) are made of brass, and are not nickel plated. (Standard) G G G ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. (Made to Order) G9-P2-02-X30 G9-P0-02-X30 Other versions of this can be made on a made-to-order basis. Please consult with SMC for details, as delivery times may be extended. psi 0 to 30 0 to 50, psi ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. Pressure gauge Size 9 ø G Outside diameter Max. display pressure Unit P2 ) 0.2, 30 psi P0 ).0, 50 psi ) This symbol must be used with X30. X3 X30 Specifications Wetted parts stainless steel (2) Both and psi ) Cover ring assembly is not available. 2) Movable parts (gear, etc) inside pressure gauge are made of brass. Size

13 G 657

14 Pressure Gauge for Clean egulator/ With Limit Indicator Series G6-S A/B G S A,B Be sure to read the precautions on page 663 for selection and mounting. Dimensions G S A, B Dimensions in ( ): / connecting G SB: With cover ring assembly (For panel mount) Panel cut dimensions Plate thickness Max. 3.5t Port size () precision Fluid contact part cleaning (Wetted part) Assembly/environment Material () Attachment: cover ring assembly Packaging Case Stud C C G6- -SA G6- -SB Back side Oil/Water free Oil/Water-free (3) Part no.: A Part no.: A ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product failure. Use a pipe tape for sealing. ecommended tightening torque: 8 : Set between 7 and 9 N m, : 2 and N m respectively. 2) When using water, use caution not to apply water hammer. When using other fluids, please consult with SMC for compatibility information concerning corrosion potential. 3) When manufacturing pressure gauge, SMC uses caution not to allow water to remain in the wetted parts. ) Movable parts (gear, etc) inside pressure gauge are made of brass. Precision cleaning Clean room M5.5 (Class 0000) Polyethylene cap for stud parts. tight polyethylene bag, 8 ±3% F.S. (Full span) General degreasing General production line Stainless steel 30 (Black melamine painted) Polycarbonate (Hard coated) Part no.: G Stainless steel 36 Bourdon tube Stainless steel 36 Polyethylene cap for stud parts. Polyethylene bag Mass (kg) C ( is not removable.) C ( is removable.) (Standard) G6-2-0 to 02-SA G6-2-0 to 02-SB G6--0 to 02-SA G6--0 to 02-SB G SA G SB G SA G SB 8 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. (Made to Order) G6-P2-0 to 02-SA-X30 G6-P0-0 to 02-SB-X30 Made-to-order products, (not including models above) may take longer leadtime. Please consult with SMC beforehand. Other versions of this can be made on a made-to-order basis. Please consult with SMC for details, as delivery times may be extended. psi 0 to 30 0 to 50, psi 8 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. 658

15 Pressure Gauge for Clean egulator/ With Limit Indicator Series G6-S A/B G SA Pressure gauge Size 6 ø2.5 Outside diameter Specifications X30 Both and psi Part number for pressure gauge with psi s is G6-P - -X30. This will no longer be sold for use in Japan after the new Weight and Measure Act has been implemented (October, 999). Max. display pressure P2 ) P0 ) Unit , 30 psi.0, 50 psi ) This symbol must be used with X30. Size Attachment Specifications Without cover ring assembly has no protrusion. C ( is irremovable.) has protrusion. C ( is removable.) Grade Component parts polishing, Assembly environment Component parts: Precision cleaning SA Assembly: Clean room M5.5 (Class 0000) Component parts: General degreasing SB Assembly: General production line G Specifications M With M5 (Female ) ) Use M5 female when panel-mounting for piping. 659

16 Pressure Gauge with Switch Series GP6 A pressure switch function has been added to the gauge. The pressure switch is equipped with a light for verifying operation. The pressure gauge is equipped with a limit indicator. To be used for verifying the supply pressure. Circuit Example Be sure to read the precautions for selection and mounting. Gauge Pressure switch Ambient and fluid temperature Indicated pressure rang Port size () precision (3) () Setting range Hysteresis Pointer error (5) Contact Wiring AC Indicator light DC Attachment: With cover ring assembly Mass (kg) GP6-0-0 to 02 GP6-0-0 to 02L2 GP6-0-0 to 02L5 C GP6 Back side 5 to 60 C (No freezing) /8, / ( M: with M5 female ) ± to ±0.05 (5 to 0 C) ±0.08 ( 5 to 60 C) No freezing With light: a (Normally open) Without light: ab (Normally open/ Normally closed) Lead wire (Length: 300 mm) Neon light Light emitting diode (LED) Part no.: G Part no.: 3050-A ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product to be damaged. Use a pipe tape for sealing. ecommended tightening torque: /8: Set between 7 and 9 N m, /: 2 and N m respectively. 2) Water is not an acceptable fluid. When using the other fluids, please consult with SMC for compatibility information concerning corrosion. 3) Set value of pressure switch is indicated by pointer (green). It is the point where the circuit between N.O. (white) and COM (black) is turned off during pressure decrease. To set the value, turn needle in clockwise position to the correct value. When setting; if desired set position has been passed, turn needle in a counterclockwise direction back again beyond the desired value and then once again return needle in a clockwise direction stopping at the desired value. Value must be set while needle is traveling in a clockwise direction. ) Make sure to provide a minimum difference of 0. between the set pressure and the operating pressure (including the pressure drop). If the difference is smaller, it could lead to improper operation. efer to page 662 for details on how to set the setting needle. Use caution: Operating pressure should be the sum of the pressure of the setting needle error (±0.05 ), the hysteresis (0.07 ), and the display accuracy (±0.05 ) on the set pressure value, or the circuit between N.O. (white) and COM (black) may not turn ON while pressure is increasing. 5) Maximum error value: Add the pressure gauge indicator error of 0.03 to the setting needle error. (Standard) 0.2 Other versions of this can be made on a made-to-order basis. Please consult with SMC for details, as delivery times may be extended. 8 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. (Made to Order) GP6-0-0 to 02-X20 GP6-0-0 to 02L2-X20 GP6-0-0 to 02L5-X20 GP6-P0-0 to 02-X30 GP6-P0-0 to 02L2-X30 GP6-P0-0 to 02L5-X30 Other versions of this can be made on a made-to-order basis. Please consult with SMC for details, as delivery times may be extended. psi 0 to 0, psi 8 Lead wire length 3 m ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. 660 Micro-switch ated Voltage Load ated voltage Operating current range Load resistant 30 VDC 25 VAC 250 VAC 0.0 to 0.5 A 0.0 to 0.3 A 0.0 to 0.2 A

17 Pressure Gauge with Switch Series GP6 GP Pressure gauge with switch 6 Size Outside diameter ø2.5 Max. display pressure 0 P0 Unit.0.0, 0 psi ) Indicate X30 for special specifications when displaying P0. Size M Specifications With M5 (Female ) Specifications X30 Both and psi X20 Lead wire length 3 m ) X3 (Wetted parts stainless steel) specification is not available. Attachment Specifications Without cover ring assembly has no protrusion. C ( is irremovable.) ) C ( has protrusion. ( is removable.) is not compliant. Indicator light Without indicator light L2 Neon light (00 VAC/220 VAC) L5 LED/2 VDC G Circuit Diagram Without indicator light NC. (ed) Dimensions GP6 Limit indicator NO. (White) COM. (Black) Pointer (Green) Setting screw Indicator light ( ): / With indicator light 0, 220 VAC 2 VDC GP6: With cover ring assembly (For panel mounting) NC. (ed) NO. (White) Load NC. (ed) NO. (White) Load is not removable. COM. (Black) COM. (Black) The arrow in the diagram indicates the direction of the pressure increase. The light turns OFF when the pressure becomes higher than the set pressure and turns ON when the pressure becomes lower than the set pressure. Panel cut dimensions Plate thickness Max. 3.5 t efer to page 662 for mounting method. 66

18 Pressure Gauge Guide Procedure for Setting the Limit Gauge Indicator () Before setting the (green) limit indicator, turn the cover counterclockwise (approximately 6 to 7 mm) until it stops. Then, remove by pulling it towards you. Cover Turn counterclockwise Pull (2) Use a flat head screwdriver (with a 2.9 mm blade width) to set the (green) limit indicator. Be careful not to bend the other needle or damage the dial plate. Limit indicator Procedure for Setting the Limit Gauge Indicator and the Setting Needle () Before setting the limit indicator and the (green) setting needle, turn the cover counterclockwise (approximately 6 to 7 mm) until it stops. Then, remove by pulling it towards you. Cover Turn counterclockwise Pull (2) Use a flat head screwdriver (with a 2.9 mm blade width) to set the (green) limit indicator. Be careful not to bend the other needle or damage the dial plate. Limit indicator Flat head screwdriver (3) After completing the setting, replace the cover. Fit the cover by aligning the cutout in the cover to the groove on the top of the black case. Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make sure that the matching mark on the cover is aligned with the groove on the top of the case. Top hollow Flat head screwdriver (3) Before setting the setting needle, use a flat head screwdriver (with a 2.9 mm blade width) to turn the setting screw and set the setting needle to the set pressure. In the case of turning the set screw Clockwise Increase of setting press. Counterclockwise Decrease of setting press. Flat head screwdriver Mark Slit () After completing the setting, replace the cover. Fit the cover by aligning the cutout in the cover to the groove on the top of the black case. Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make sure that the matching mark on the cover is aligned with the groove on the top of the case. Procedure for Setting the Limit Gauge Indicator (Color Zone ) () Before setting the color zone (red), turn the cover counterclockwise (approximately 6 to 7 mm) until it stops. Then remove by pulling it towards you. Top hollow Slit Cover Mark Turn counterclockwise (2) Use a pen tip to set the color zone (red). Be careful not to bend the other needle or damage the dial plate. Pull Procedure for Assembling the Cover ing Assembly Pressure gauge for general purpose Cover ring Pressure switch Attach small screw Pen tip Color zone emove screw Pressure gauge with switch (3) After completing the setting, replace the cover. Fit the cover by aligning the cutout in the cover to the groove on the top of the black case. Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make sure that the matching mark on the cover is aligned with the groove on the top of the case. Top hollow Slit emove screw. emove the small screw ( position) from the pressure gauge. 2. Place the cover ring on the pressure gauge. 3. Using the small screw that is provided with the cover ring, install the cover ring. The installation torque is 0.3 to 0.5 N m. Mark 662

19 Pressure Gauge Guide Specific Product Precautions Be sure to read this before handling. efer to front matters 58 and 59 for safety precautions. Selection Caution. Do not apply high load voltage (current) or surge current as this can cause the switch to malfunction. 2. Make sure that no direct impact or vibrations are applied to the body. 3. If operating under pressure pulsations or in high frequency operations, please contact SMC. Mounting Caution. During transport and installation, do not apply shock to the product, such as by dropping doing so will affect its precision. 2. egarding the installation posture, place it perpendicular to the ground, with the zero point on the reading of a pressure gauge facing down. 3. Do not install it in an area that is exposed to high temperature or humidity, because doing so will lead to improper operation.. To screw in the pressure gauge, make sure to turn the gauge by placing a wrench over the square wrench flats. If the pressure gauge is screwed in by holding it on some other area, air leakage or damage may result. G 663

Pressure Gauge Guide

Pressure Gauge Guide ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A 900-6370-Main Office: (650) 5-9200- Local Area: (00) 25-9200-www.stevenengineering.com Gauge for General Purpose With limit indicator

More information

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ Clean Regulator Series IR IRV VEX SRP ITV IC T AP1 Contamination controlled stainless steel regulator 855 Clean Regulator Series Contamination controlled stainless steel regulator Oil free Outstanding

More information

Miniature Regulator Series ARJ310

Miniature Regulator Series ARJ310 Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42) Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette Finger Valve Series VHK ohs Large effective area:.0 to 7.5 mm Small knob operating force: 0.04 to 0.4 N m Poppet valve construction seldom suffers seal defection. The series begins with the min. tubing

More information

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note) [Option] The flow switch, series IFW is used for detection and confirmation of the flow as a relaying device for the general water applications in some various equipment such as cooling water fixture in

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Pressure measurements can easily be taken any time, anywhere. RoHS Compact and lightweight Portable type with a lightweight of only about 00 g (unit 50 g, battery 50 g) can also be held

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting Series Elbow Type Reduces labor time! Elbow Brass Stainless steel Electroless nickel plated Stainless steel 33 RoHS TMH y Easo t e us Push-lock type Larger handle

More information

ARM1000/2000. Standard Specifications

ARM1000/2000. Standard Specifications .5- Regulator Manifold ARM000/000 4 connection methods Standard Specifications Fluid Proof pressure Max. operating pressure Set pressure range Ambient and fluid temperature Cracking pressure (Valve) Construction

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Compact Slide. Series MXH ø6, ø10, ø16, ø20 Compact Slide Series ø, ø, ø, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. Endless track linear guide Series Variations

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Transmitters: Relay Valve VR4151/4152

Transmitters: Relay Valve VR4151/4152 Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such

More information

Note) Rated flow (l/min (ANR)) Port size 1 8, , , , , 1 1, , 2

Note) Rated flow (l/min (ANR)) Port size 1 8, , , , , 1 1, , 2 Mist Separator Series ohs Can remove oil mist in compressed air and separate and remove particles such as rust or carbon of more than 0.3 µm. Modular connection is possible with 150C to 550C. (For details,

More information

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model. Speed Controller with Uni One-touch Fitting Push-lock type Series Elbow Universal Brass New-stand male threads for piping that reduces the screw-in time by 1/3. Gasket Female thread Rc, G NP, NPF Shape

More information

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation Air Catch Sensor Non-Contact Sensor for Workpiece Placement Confirmation Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact type

More information

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette Finger Valve Series RoHS Large effective area:.0 to 7.5 mm Small knob operating force: 0.04 to 0.4 N m Poppet valve construction seldom suffers seal defection. The series begins with the min. tubing O.D.

More information

Transmitters: Relay Valve

Transmitters: Relay Valve Relay Valve VR5/5 Series Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system. Specifications

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42) Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable

More information

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP Micro Ejector Order Codes Manifold Order Codes Micro ejector single unit (without solenoid valve) ME Body model nozzle diameter : Maximum flow rate on vacuum side 03 0.3 : 3.0R/min. [0.012in., 0.106ft.

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

SPEED CONTROLLERS WITH QUICK FITTINGS

SPEED CONTROLLERS WITH QUICK FITTINGS SPEED CONTROLLERS WITH QUICK FITTINGS Union Straight Type Fittings for controlling the speed of actuators, such as cylinders. Superior flow rate characteristics and fine tuning adjustments in the low flow

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

Series VM. Mechanical Valve. VM1000 Side piping Bottom piping. VM100 Side piping Bottom piping VM200. Model Dimensions (mm) 2-38.

Series VM. Mechanical Valve. VM1000 Side piping Bottom piping. VM100 Side piping Bottom piping VM200. Model Dimensions (mm) 2-38. Mechanical Valve Series VM Model Dimensions (mm) VM1000 Side piping Bottom piping 11 X 36 X 16 11 X 28 X 25 VM100 Side piping Bottom piping 17 X 44 X 25 17 X 44 X 30 VM200 25 X 40 X 52 Basic Roller Lever

More information

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves. ME12, ME25, ME60 Specifications Micro ejectors Media Operating pressure range MPa [psi.] Operating temperature range C [ F] Nozzle diameter Note mm [in.] kpa [in.hg] flow rate Note R/min [ft. 3 /min.]

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4 Pilot check valve and speed controller are combined. Realizes momentary intermediate stoppage of a cylinder and able to adjust speed control of it. Work piece Example of drop prevention circuit Tubing

More information

Angular Style Air Gripper

Angular Style Air Gripper Angular Style Air Gripper Series /A/M 15 Angular style air gripper Series /A/M - Auto switch is attachable. 8 mm x 0 mm x mm g Body option (Only for A-) Side piping Port Port A- Short body. 1 mm x 0 mm

More information

SECTION METERS AND GAUGES FOR HVAC PIPING

SECTION METERS AND GAUGES FOR HVAC PIPING SECTION 23 05 19 METERS AND GAUGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Work included: Provision of materials, installation and testing of: 1. Thermometers 2. Thermometer Wells 3. Differential

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold Pressure range 9 Option. MPa. MPa.9 MPa kpa Option How to Order N Power supply voltage 24 VDC ±% 2 to VDC Option

More information

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody I INTRODUCTION These rugged, versatile, high performance, regular port, ball valves meet all requirements

More information

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type 230.15 Mechanical Pressure Measurement WIKA Datasheet 230.15 Applications Semiconductor and electronic industry, medical industry, gene

More information

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type 230.15 Mechanical Pressure Measurement WIKA Datasheet 230.15 Applications Semiconductor and electronic industry, medical industry, gene

More information

Vacuum System Peripherals

Vacuum System Peripherals Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

Series ZM Applications

Series ZM Applications Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

YCCS TE-6800 Series Temperature Sensors

YCCS TE-6800 Series Temperature Sensors YCCS TE-6800 Series Temperature Sensors TE-68xx-xNN0S Installation Instructions 85-YIM-B-070 Applications The York Commercial Comfort System (YCCS) TE-68xx-xNN0S Series Temperature Sensors provide temperature

More information

Speed Controller with Indicator

Speed Controller with Indicator Speed Controller with Indicator The numerical indication of flow rate knob rotations reduces flow setting time and setting errors! Elbow Universal Brass Electroless nickel plated RoHS Stainless steel 1

More information

Low Maintenance Filter

Low Maintenance Filter Low Maintenance Filter Series FN/FN4 No more element replacement! Our unique element construction with back-flushing capability The element of the filter is constructed of a series of grooved filter plates

More information

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation Air Catch Sensor Series ISA For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. ZSE ISE ZSP

More information

Exhaust Cleaner for Clean Room. Body size. Symbol Nil. Size 1/4 standard 3/8 standard 1/2 standard. Element construction. Stage 2 stage.

Exhaust Cleaner for Clean Room. Body size. Symbol Nil. Size 1/4 standard 3/8 standard 1/2 standard. Element construction. Stage 2 stage. Exhaust Cleaner for Clean oom Series ohs An exhaust cleaner that can be used inside a clean room How to Order 0 0 Exhaust air cleanliness: Equivalent to ISO Class (Class 0 ed.std.0) (Consult SMC in advance,

More information

5. SEPARATE STEERING INTERMEDIATE SHAFT ASSY (a) Fix the steering wheel with the seat belt. Release the 3 springs and separate the dust cover.

5. SEPARATE STEERING INTERMEDIATE SHAFT ASSY (a) Fix the steering wheel with the seat belt. Release the 3 springs and separate the dust cover. 5119 OVERHAUL When installing, coat the parts indicated by the arrows with power steering fluid or molybdenum disulfide lithium base grease (See page 5116). 1. INSPECT CENTER FRONT WHEEL 510DA02 2. REMOVE

More information

CVE2/CVSE2 CVE3/CVSE3

CVE2/CVSE2 CVE3/CVSE3 Overview This is a reliable 2, 3 port coolant valve with cylinder drive method. This valve for tool machine cutting oil or coolant control incorporates a metal seal to prevent the entry of cutting chips,

More information

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC Air Suction Filter Series ZF Prevent from occurring vacuum equipment trouble due to dust from vacuum pad Series ZFA ZF Universal joint type Features Long maintenance cycle type (Large filter surface) Adaptable

More information

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange Can separate and remove aerosol state oil mist in compressed air and remove particles such as carbon or dust of more than 0.01 μm. Use this product as a pre-filter for compressed air for precision instruments

More information

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level. SERIES LED Bar Display Mechanical Switch is Out of Date Choose the Contemporary Pressure Sensor with LED Bar Display Marked Conforming to EMC directive Bright LED Bar Display Easy to read the pressure

More information

WINTERS ( )

WINTERS ( ) Economy Economy Test Panel Mounted Economy Spiral Tube Series New Sizes! Economy CRN Description The Winters Economy Gauge is designed for applications where cost savings are paramount. Many configurations

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting S Series Push-lock Type Reduces labor time! Easy to use Easy to lock Unlock Push-lock type Lock Improved tube insertion/removal Max. Insertion force: 30% (8 N) reduction

More information

Related Products VR4151/4152 Relay Valve

Related Products VR4151/4152 Relay Valve Related Products VR4151/4152 Relay Valve Appropriate output sequences are affected according to the signal received from the machanical valve. Specifications 1 Fluid Air Operating pressure 0 to 1.0MPa

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

Specifications MHC2-10D MHC2-16D MHC2-20D MHC2-25D MHC2-10S. Double acting MHC2-16S. Single acting MHC2-20S MHC2-25S. Angular style air gripper

Specifications MHC2-10D MHC2-16D MHC2-20D MHC2-25D MHC2-10S. Double acting MHC2-16S. Single acting MHC2-20S MHC2-25S. Angular style air gripper Angular Style Air Gripper Standard Type Series MHC2 Size: 10, 16, 20, 25 A large amount of gripping force is provided through the use of a double piston mechanism, while maintaining a compact design. Built-in

More information

Precision Clean Regulator

Precision Clean Regulator Precision Clean Regulator Series AR45 AMR ARM -A VY AP00 High precision, low flow consumption stainless steel regulator 869 Precision Clean Regulator Series High precision, low flow consumption stainless

More information

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter Clean Air Module Series Digital flow switch Regulator ON/OFF valve Restrictor Filter Modularizes clean equipment (Reduced piping man-hours/space-saving). Easily obtains clean air. Built-in one-touch fitting

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Compact direct acting precision regulator

Compact direct acting precision regulator direct acting precision Components preparation and pressure adjustment / unit CONTENTS Product introduction 6 Safety precautions 62 Discrete (RJB500) 624 Block manifold (MNRJB500) 626 Block configurations

More information

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A) ort Solenoid Valve ubber Seal Series SY00 Low power consumption: 0.W (Standard, Without light) (Current draw: m at V DC) Large flow capacity style:0.7w (Current draw: m at V DC) Body width: 0mm 7.8 Nl/min

More information

Ready for outdoor use too!

Ready for outdoor use too! Filter/regulator assured for outdoor use New Product Filter/regulator series First in the industry FILTER REGULATOR FOR DOOR USE Ready for outdoor use too! Improved outdoor durability due to the exterior

More information

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm. SERIES LED Display Anti-corrosive Digital ure Sensor DP3 ure Measurement of Corrosive Gases and Liquids Possible! Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless

More information

M9216 Series Electric Spring Return Actuators

M9216 Series Electric Spring Return Actuators *34636461G* 34-636-461, Rev. J Installation Instructions M9216 Issue Date October 217 M9216 Series Electric Spring Return Actuators Installation IMPORTANT: The M9216 Series actuator is intended to control

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type Mechanical Pressure Measurement Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type 230.15 WIKA Datasheet 230.15 Applications Semiconductor and electronic industry, medical industry, gene

More information

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8 Precision Cylinder Series, ø, ø6, ø, ø, ø, ø MXS Series Variations Model 8 Standard stroke (mm) 7 7 Rod end configuration Cushion Rubber bumper End lock Made to Order Rod Variable stroke/ through-hole

More information

HN B G1/US B G2/US B G3

HN B G1/US B G2/US B G3 HN B G/US B G/US B G Compact direct acting, port solenoid valve air, water,, low vacuum (. x 0 Pa (abs)) CONTENTS Safety precautions port solenoid valve HNB NC (normally closed) type USB NC (normally closed)

More information

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves MicroCoat System Operating Manual MC Series MC785M, MC785M-WF Spray Valves A NORDSON COMPANY Introduction The MicroCoat System provides precise lubrication control for metal stamping operations. The MC

More information

Vacuum Ejector. Adaptable for manifold application

Vacuum Ejector. Adaptable for manifold application Vacuum Ejector Series ZM ZX All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum Vacuum release valve (equipped with a flow volume adjustment valve) Vacuum pressure

More information

How to Order IFW5 10 N Diaphragm Style Flow Switch to 10 l/min NPT. Port size. Specifications. Contact. Port size

How to Order IFW5 10 N Diaphragm Style Flow Switch to 10 l/min NPT. Port size. Specifications. Contact. Port size Flow Switch Diaphragm Style Series IFW5 IFW Series Flow Switches detect and confirm flow. They are applicable to general industrial machines and various other applications. How to Order IFW5 N 3 Q Low

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

POWER STEERING TO INDEX POWER STEERING SYSTEM PRECAUTIONS... OPERATION CHECK... PROBLEM SYMPTOMS TABLE... VANE PUMP ASSEMBLY COMPONENTS...

POWER STEERING TO INDEX POWER STEERING SYSTEM PRECAUTIONS... OPERATION CHECK... PROBLEM SYMPTOMS TABLE... VANE PUMP ASSEMBLY COMPONENTS... TO INDEX STEERING POWER STEERING POWER STEERING SYSTEM PRECAUTIONS.............................................. OPERATION CHECK......................................... PROBLEM SYMPTOMS TABLE.................................

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

How to Order M9BW. Action. Double acting Single acting. Load voltage Electrical entry direction M9NWV M9NW 12 V 5 V, M9BWV M9BW 12 V 12 V

How to Order M9BW. Action. Double acting Single acting. Load voltage Electrical entry direction M9NWV M9NW 12 V 5 V, M9BWV M9BW 12 V 12 V Angular Type Air Gripper/Standard Type 2 Series ø, ø1, ø20, ø25 How to Order Angular type air gripper 2 20 Bore size mm 1 1 mm 20 20 mm 25 25 mm D S Action D Double acting Single acting M9BW Made to Order

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

Low Maintenance Filter

Low Maintenance Filter Low Maintenance Filter FN/FN Series No more element replacement! Our unique element construction with back-flushing capability The element of the filter is constructed of a series of grooved filter plates

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

BALL VALVES FILTERS TEST POINTS 8

BALL VALVES FILTERS TEST POINTS 8 BALL VALVES FILTERS TEST POINTS 8 8 PRODUCT CATALOGUE 357 HYDROSCAND BALL VALVES, FILTERS TEST POINTS TABLE OF CONTENTS BALL VALVES PAGE BALL VALVES The ball valves are mainly used as shut-down valves

More information

Series PW

Series PW Series 2000300040005000 Filter Regulator Specifications H U 2000 3000 Model 2000 3000 5000 Port size Rc(PT)/NPT 1/8", 1/4" 1/4", 3/8" 3/8", 1/2" 3/4", 1" Max. Supply Pressure 1.5MPa(213 PSI) Max. Operating

More information

Manifold Isolation Valves

Manifold Isolation Valves 300 N. Opdyke Rd. Introduction The Stainless Manifolds are designed for use in Hydronic radiant panel heating and cooling applications. They are available in various sizes, configurations, and options

More information

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa Series 0-PSE50 Remote type pressure sensor How to Order Clean series 0 PSE5 0 M5 Pressure sensing range Option 0 2 High pressure [0 to MPa] Vacuum [0 to 0 kpa] Low pressure [0 to 0 kpa] Compound pressure

More information

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

LEAD FREE * LFM115 (Globe) LFM1115 (Angle) ES-ACV-SB-LFM115_LFM1115 LEAD FREE * Pressure Reducing Control Valve Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS) P/L

More information

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil Ionizer / with surface potential sensor Series IZS0 How to Order 00 0 00 00 Ionizer IZ S 0 0 Bar length Bar length 00 mm 0 mm mm 00 mm 00 mm Ionizer Made to Order Bar type Size Electrode needle material

More information

240 g. 290 g. Electric Actuators Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type

240 g. 290 g. Electric Actuators Series LEPY/LEPS. Miniature Rod Type/Miniature Slide Table Type Electric Actuators Series / Miniature Rod Type/Miniature Slide Table Type RoHS Compact and lightweight Rod Type Series Weight 24 g 6-25 Maximum pushing force: 5 N Positioning repeatability:.5 mm Possible

More information