1 Flow Switch Diaphragm Style Series IFW5 IFW Series Flow Switches detect and confirm flow. They are applicable to general industrial machines and various other applications. How to Order IFW5 N 3 Q Low flow setting possible ( l/min) Simple flow setting Without removing the cover, you can set it with a screwdriver from the outside. Diaphragm Style Flow Switch Flow range to l/min 2 to 2 l/min Light Without neon light With neon light (V AC, red) 2 With neon light (V AC, green) 3 With neon light (22V AC, red) 4 With neon light (22V AC, green) 5 2 to 5 l/min Terminal Box Thread Without Terminal Box (Contact: ab) N Rc(PT) NPT 2 With Terminal Box (Contact: ab) WithTerminal Box (Contact: 2b) F G(PF) Port size PAT. PEND 3 4 3/8 /2 6 3/4 Specifications Fluid Water, Non-corrosive liquid Operating pressure Proof pressure Operating temperature Operation Insulation Voltage proof Contact Port size Body Body material in contact Rod with fluid material Diaphragm When using, contact an SMC representative.. to.6mpa.2mpa 5 to 6 C Diaphragm MΩ (DC5) 5V AC for one min. Without Terminal Box: ab With Terminal Box: a or b 3/8, /2, 3/4 BC6 C364B NBR 3.4-

2 Series IFW5 Micro Switch Ratings Model Voltage 25V AC 25V AC 8V DC 4V DC 3V DC 25V DC 25V DC Non-inductive Load (A) Inductive load (A) Resistance load Lamp load Inductive load Motor load N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O Model Flow range (l/min) Max. flow Hysteresis () (l/min) (l/min) IFW5 to 2 or less IFW52 IFW55 to 2 2 to or less 3 or less Note ) Hysteresis is the flow rate that is necessary for moving the microswitch from the operation position (ON signal) to the return position (OFF signal). Construction/Operation Flow Characteristics IFW5 Pressure drop (MPa) IFW52 Pressure drop (MPa) P =.6MPa P =.5MPa P =.4MPa P =.3MPa P =.2MPa P =.MPa Flow rate (l/min) P =.6MPa P =.5MPa P =.4MPa P =.3MPa P =.2MPa P =.MPa Operation principles Liquid flow creates a pressure differential nearby the orifice of the port of the body. One set of diaphragms monitors the pressure differential and operates the micro switch through the rod w and operating lever r. The rod moves downward with increased flow, and upward with decreased flow. Moving the gear e upward or downward by the adjusting gear t manually offers an electric signal at various flow rates. Parts List No. Description q Body w Rod e Gear Material BC6 C364B POM No. r t Description Operating lever Adjusting gear Material SPCC POM IFW55 Pressure drop (MPa) Flow rate (l/min) P =.6MPa P =.5MPa P =.4MPa P =.3MPa P =.2MPa P =.MPa Flow rate (l/min)

3 Diaphragm Style Flow Switch Series IFW5 Dimensions IFW5 - - to 4 (Without Terminal Box) IFW5 - - to 24 (With Terminal Box) 3.4-3

4 Series IFW5 Internal Wiring Diagram IFW5 - -,, 2 Symbol Contact C COMMON A NORMALLY OPEN B NORMALLY CLOSED IFW5 - to 4, to 4, 2 to 24 Symbol Contact C COMMON A NORMALLY OPEN B NORMALLY CLOSED Color of Lead Black White Red Color of Lead Black White Red Precautions Be sure to read before handling. Refer to p.-26 and -27 for Safety Instructions and common precautions on the products mentioned in this catalogue. Caution Mounting Terminals qmount the switch so that the flow of liquid is in the same direction as that of the arrow on the body. wthe flow switch can be installed either horizontally or vertically. efor wiring, refer to the internal wiring diagram. rif a terminal box is not available, wire by selecting the contact at a or b. At that time, insulate the lead wires that will not be used. tbecause this is an open style, it cannot be used where water or oil splashes. yit cannot be used if a water hammer or pulsation pressure is applied to the fluid. uto prevent improper operation or diaphragm damage due to the presence of debris or cutting chip in the fluid, provide a filter of approximately mesh on the primary side of the flow switch. Caution Adjusting qto adjust flow, remove grommet of the upper cover and rotate flow adjusting gear using a screwdriver. (clockwise rotation: increase of adjusting flow rate, counterclockwise rotation: decrease of adjusting flow rate) walign the indicator needle to the graduation on the left side of the window name plate if the IN side pressure is.mpa, and to the graduation on the right side if the pressure is.2mpa. (Refer to Fig..) ethe flow rate setting point is set at the ON flow rate. Therefore, in the case of the a contact, the ON signal is output if fluid with a higher flow rate than the set flow rate has flowed. In the case of the b contact, the OFF signal is output when the flow rate has decreased from the set flow rate for the amount that corresponds to the hysteresis. rif the IN side pressure exceeds.2mpa, the setting cannot be made with the graduation on the window name plate. Therefore, perform the setting by installing a flow rate gauge on the secondary side of the flow switch. tto prevent the chattering that is associated with the fluctuation of the operating flow rate, set the difference between the set flow rate and the operating flow rate so that it is as large as possible. yuse at or below the maximum operating pressure and maximum flow rate

5 Flow Switch Paddle Style Flow Switch Series IF3 IF3 Series flow switches detect and confirm liquid flow, generally used in fields such as air conditioning, water supply equipment, etc. How to Order IF3 N Q Piping sizes range from 3/4 B to 6 B. Wide range of applicable fluids. Materials in contact with fluid: Copper alloy, Stainless steel Various enclosures (water proof). Standard style, Drip proof style, Splash proof style. Paddle Style Flow Switch Enclosure 2 Standard (Non water proof) Drip proof Splash proof Seal material NBR FPM Metal material in contact with fluid Copper alloy SUS34 ON flow range 4 to 6 l/min 2 to 5 l/min 3 36 to 26 l/min Thread Rc(PT) N NPT Port size 6 3/4 Note ) IF3 is available for "6". Note 2) IF3 and IF3 3 are available for "". Specifications Fluid Max. operating pressure Proof pressure Isolation Voltage proof Contact Port size Copper alloy SUS34 Water, Non corrosive liquid Liquid compatible with stainless steel MPa.75MPa MΩ (DC5) 5V AC for one min. ab 3/4, Micro Switch Ratings Non inductive load (A) Inductive load (A) Voltage Resistance load Light load Inductive load Motor load N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. 25V AC 25V AC 8V DC 4V DC 3V DC 25V DC 25V DC

6 Series IF3 Fluid and Ambient Temperature Range Enclosure Fluid temperature Corresponding ambient temperature () Standard Indoor applications away from moisture 7 C or less 7C (7C ) or less 8 C 58C (6C ) or less 9 C 47C (5C ) or less C 35C (4C ) or less Note ) ( ) For IF32 Drip proof (JIS C92) Splash proof (JIS C92) Indoor or outdoor applications can tolerate water drip Sealed construction can tolerate hosing or salt laden atmosphere Construction Flow Characteristics List Fluid: Water, secondary pressure: MPa Sealing thread depth: 9mm( 3 / 4 ), mm() Flow Switch IF3-6 Mounting Port size Paddle size 3 / 4 3 / 4 Flow range (l/min) Minimum ON flow 4 8 OFF flow min 7 9 Maximum ON flow OFF flow min ON-flow rate/setting (meter/sec.) to to / to to.67 / to.67 / to to.6 IF3-2 / to to to , to ,5,3.4 to to 3.5 / to 2.67 Main parts list No. Description q Cover w Mounting plate e Bellows r Body t Mobile bar y Paddle u O ring Material IF3 IF3 IF32 SPCD SPCD ADC2 SPCC SUS34 PBP or SUS34 C364B or SUS34 C27W or SUSXM7 SUS34 NBR or FPM SUS34 IF3 3- / / ,,8 2,6 23. to to to to to.9,45.69 to ,.7 to 2.28 ON-flow: Switch point at increase of flow. OFF-flow: Switch point at decrease of flow. Maximum flow can be up to twice of ON-flow. Accurate operating flow depends on correct sealing depth and direction of flow

7 Paddle Style Flow Switch Series IF3 ON-Flow Change due to Pressure Pressure Drop Curve ON-Flow change (%) Min. ON-Flow Max. ON-Flow Pressure (MPa) Pressure drop (MPa) /4 Pipe Pipe 2,3 Pipe /4,4,5 Pipe /2,2 /2,6 Pipe Flow speed (m/s) Precautions Be sure to read before handling. Refer to p.-26 and -27 for Safety Instructions and common precautions on the products mentioned in this catalogue. Caution Mounting & Wiring qmount the switch on top of horizontal pipe so that fluid flow is in the direction of the arrow. Sealing depth should be 9mm±mm for 3/4 and mm±.2mm for. win terms of the direction of installation, this product can only be installed perpendicularly to the horizontal pipe. eprovide a straight pipe portion that corresponds to approximately 5 times the bore of the pipe before and after the area of the pipe on which the product is installed, thus keeping the product as far away as possible from the elements that disturb the flow, such as elbows or valves. rthree types of paddles, short, medium, and long, are provided with each model. Use one of them according to the pipe size and the set flow rate. tuse pipe fittings that comply with JIS specifications. For 3/4B to 3B, use commercially available union tees of different diameters. For 4B to 6B, use a B socket that has been cut in half and welded. Applicable Fittings For pipe fitting 3/4 through 3 For pipe fitting 4 through 6 Piping B Reducing Tees B X X / / 4 X 4 / 4 X / / 2 X 2 / 2 X 2 2 X 2 X 2 / 2 / 2 X 2 2 / 2 X 3 3 X 3 X Reducing tees: JISB23 Socket: JISB232 Pipe: JISB3452 Caution Adjusting qto adjust flow, remove grommet of the upper cover and rotate flow adjusting gear using the minus driver. (clockwise rotation: increase of adjusting flow rate, counterclockwise rotation: decrease of adjusting flow rate) wflow rate % relation to the number of turns is shown in the table below. However, this is just a guide. For precise setting use a flow meter. Number of turns Contact ON-Flow (%) ethe flow rate setting point is set at the ON flow rate. Therefore, in the case of the a contact, the ON signal is output if fluid with a higher flow rate than the set flow rate has flowed. In the case of the b contact, the OFF signal is output when the flow rate has decreased. Refer to the flow rate characteristics table for details on the operation flow rate. rdo not touch the two types of stop screws that are indicated on the construction diagram. tto prevent the chattering that is associated with the fluctuation of the operating flow rate, set the difference between the set flow rate and the operating flow rate so that it is as large as possible. yuse at or below the maximum operating pressure and maximum flow rate. uspare parts, medium, and long paddles are provided as a 3 piece set with each model, so arrange them as indicated below. There is no compatibility between the paddle for a 3/4 connecting bore and for a because their installation pitches differ. Arrangement example: Paddle set for IF3-6- yit cannot be used in case a water hammer or pulsation pressure is applied to the fluid. uwire the microswitch according to the symbols on the upper insulators. (They will be opposite the terminal symbols on the microswitch. The terminals are screw terminals.) Internal wiring diagram Symbol C A B Contact COMMON NORMALLY OPEN NORMALLY CLOSED 3.4-7

8 Series IF3 Dimensions Standard style: 3/3/33 Drip proof style: 3/3/33 Model Dimensions Connection A B C D E F Model Dimension Connection A B C D E F 3 / / IF3 IF3 IF33 Splash proof style: 32/32/323 IF3 IF3 IF33 Model IF32 IF32 IF Dimension Connection A B C D E F 3 /

9 Paddle Style Flow Switch Series IF3 Flow Speed 2 3/4B (ø2.6) B (ø27.6) /4B (ø35.7) /2B (ø4.6) 2B (ø52.9) 2 /2B (ø67.9) B (ø8.7) Flow Speed (m/s) B (ø5.3) 5B (ø3.8) 6B (ø55.2) Flow rate (l/min) ( ) : Gas pipe bore sizes 3.4-9

10 3.4-

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42) Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42) Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable

More information

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note) [Option] The flow switch, series IFW is used for detection and confirmation of the flow as a relaying device for the general water applications in some various equipment such as cooling water fixture in

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

ARM1000/2000. Standard Specifications

ARM1000/2000. Standard Specifications .5- Regulator Manifold ARM000/000 4 connection methods Standard Specifications Fluid Proof pressure Max. operating pressure Set pressure range Ambient and fluid temperature Cracking pressure (Valve) Construction

More information

Transmitters: Relay Valve VR4151/4152

Transmitters: Relay Valve VR4151/4152 Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2

More information

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm 4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder Power Valve 3 Position Valve Series VEX3 A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder System construction with VEX Conventional system construction

More information

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to

More information

Transmitters: Relay Valve

Transmitters: Relay Valve Relay Valve VR5/5 Series Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system. Specifications

More information

Check Valve Series AK How to Order

Check Valve Series AK How to Order High flow capacity Low cracking pressure:.2mpa Check Valve Series AK How to Order N AK 2 2 Compact and light weight Area Code Japan, Asia, Nil Australia, UK N U.S.A. 2 4 6 Body size /4 /2 /8 2 /4 3 3/8

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications Speed Controller with One-touch Fitting Series Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube

More information

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ Clean Regulator Series IR IRV VEX SRP ITV IC T AP1 Contamination controlled stainless steel regulator 855 Clean Regulator Series Contamination controlled stainless steel regulator Oil free Outstanding

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S. High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model Suction Filter with Case FH99 Series RoHS Compact and lightweight The compact and lightweight design employs an aluminum casted housing. Prevents pump cavitation The inlet size is larger than the outlet

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

Miniature Regulator Series ARJ310

Miniature Regulator Series ARJ310 Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates

More information

Series VM. Mechanical Valve. VM1000 Side piping Bottom piping. VM100 Side piping Bottom piping VM200. Model Dimensions (mm) 2-38.

Series VM. Mechanical Valve. VM1000 Side piping Bottom piping. VM100 Side piping Bottom piping VM200. Model Dimensions (mm) 2-38. Mechanical Valve Series VM Model Dimensions (mm) VM1000 Side piping Bottom piping 11 X 36 X 16 11 X 28 X 25 VM100 Side piping Bottom piping 17 X 44 X 25 17 X 44 X 30 VM200 25 X 40 X 52 Basic Roller Lever

More information

Mini Rotary Actuator/Rack & Pinion Style

Mini Rotary Actuator/Rack & Pinion Style Mini Rotary Actuator/Rack & Pinion Style Series CRJ :, CRB2 CRBU2 CRB MSU CRJ CRA CRQ2 MSQ MSZ CRQ2X MSQX MRQ PAT. PEND D- 79 Mini Rotary Actuator Series CRJ Rack & Pinion Style/:, Compact 9.5 23.5 43(54)

More information

ACTUATORS GENERAL CATALOG

ACTUATORS GENERAL CATALOG CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG ROTARY ACTUATORS VANE TYPE SERIES CONTENTS RAN (Standard Type) Basic Model and Configuration 259 Specifications 26 Order Codes 264 Dimensions

More information

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series For controlling pneumatic

More information

Mini Rotary Actuator/Rack & Pinion Style

Mini Rotary Actuator/Rack & Pinion Style Mini Rotary Actuator/Rack & Pinion Style Series CRJ :, CRB2 CRBU2 CRB MSU CRJ CRA CRA CRQ2 MSQ MSZ CRQ2X MSQX MRQ PAT. PEND D- 79 Mini Rotary Actuator Series CRJ Rack & Pinion Style/:, Compact 9.5 23.5

More information

Series ISA. Air Catch Sensor. For Detection of Work Presence

Series ISA. Air Catch Sensor. For Detection of Work Presence ED Bar graph for easy calibration The ED bar graph indicator in conjunction with the adjustment knob for the variable orifice allows for easy and correct calibrations. Over range (Red) Correct range (Green)

More information

Compact direct acting precision regulator

Compact direct acting precision regulator direct acting precision Components preparation and pressure adjustment / unit CONTENTS Product introduction 6 Safety precautions 62 Discrete (RJB500) 624 Block manifold (MNRJB500) 626 Block configurations

More information

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type Pilot kick type 2 port solenoid valve for dry air (general purpose valve) DK11-Z Series NC (normally closed) type Port size: Rc1/4 to Rc1 Diaphragm structure JIS symbol NC (normally closed) type OUT IN

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

Flow Control Equipment

Flow Control Equipment Flow Control Equipment Speed Controller (With One-touch Fittings, Standard Style) Metering Valve with Silencer, Quick Exhaust Valve, Check Valve Safety Speed Control Valve Speed Controller with One-touch

More information

Specifications MHC2-10D MHC2-16D MHC2-20D MHC2-25D MHC2-10S. Double acting MHC2-16S. Single acting MHC2-20S MHC2-25S. Angular style air gripper

Specifications MHC2-10D MHC2-16D MHC2-20D MHC2-25D MHC2-10S. Double acting MHC2-16S. Single acting MHC2-20S MHC2-25S. Angular style air gripper Angular Style Air Gripper Standard Type Series MHC2 Size: 10, 16, 20, 25 A large amount of gripping force is provided through the use of a double piston mechanism, while maintaining a compact design. Built-in

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure Miniature Regulator Series 00F Compact and lightweight ( g) Low cracking pressure 0.0 MPa Standard model equipped with backflow function Standard Specifications Port size Fluid side side (Applicable tubing

More information

Series IW. Filter Regulator

Series IW. Filter Regulator Standard Specifications Model IW212 IW213 IW215 IW222 Adjustable type (Basic) Fixed type Maximum supply pressure Max. 1. MPa.3 to 1. MPa Set pressure.2 to.2 MPa.2 to.3 MPa.2 to.5 MPa.14 MPa Air consumption

More information

Mechanical Valve Series VM

Mechanical Valve Series VM Mechanical Valve Series VM Model Dimensions (mm) VM1000 Side piping Bottom piping 11 X 36 X 16 11 X 28 X 25 VM100 Side piping Bottom piping 17 X 44 X 25 17 X 44 X 30 VM200 25 X 40 X 52 Basic Roller Lever

More information

Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves)

Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves) Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves) 80mm 12mm 18mm Space Saving Thin and compact size Valve width: 12mm [0.472in.] Valve length: 80mm [3.150in.] Flow Large flow rate with

More information

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type) CAT.1101E-S www.sym1.com KV series Innovatively detachable Manifold Block (DIN Rail Mounting) Smart Solenoid Valve (Plug-in type, D-SUB multi-connector ) Compact size with large flow capacity Exceedingly

More information

Standard Specifications. Model. Indication precision. Clear cover. Brass Mass (kg) Bourdon tube. Model (Standard) Model G (2) G27-10-R1

Standard Specifications. Model. Indication precision. Clear cover. Brass Mass (kg) Bourdon tube. Model (Standard) Model G (2) G27-10-R1 Pressure Gauge for General Purpose Series G5/G27 G5 G27 G5-0-0 G27-0- Be sure to read the precautions on page 663 for selection and mounting. Dimensions Port size () precision ±5% F.S. (Full span) Case

More information

F61 Series Standard Flow Switches

F61 Series Standard Flow Switches Installation Instructions F61 Issue Date July 30, 2002 F61 Series Standard Switches Installation IMPORTNT: ll F61 Series Switches are intended to control equipment under normal operating conditions. Where

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

How to Order. Lead wire length Nil L Z M9N L. Type of auto switch for detecting rotation. Nil Without auto switch. Applicable Auto Switch

How to Order. Lead wire length Nil L Z M9N L. Type of auto switch for detecting rotation. Nil Without auto switch. Applicable Auto Switch Indicator light Indicator light Rotary Gripper Series MRHQ Size:, 1,, 25 How to Order Lead wire length Nil L Z.5 m 3 m 5 m MRH Q D 9 S M9NV L M9N L Q Rotary gripper Gripper Parallel type: 2 fingers D S

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter Clean Air Module Series Digital flow switch Regulator ON/OFF valve Restrictor Filter Modularizes clean equipment (Reduced piping man-hours/space-saving). Easily obtains clean air. Built-in one-touch fitting

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid Metal free, port solenoid valve for chemical liquid MY/MYG Series NC (normally closed) type, universal type Working fluid: water, pure water, chemical liquids Port size: M JIS symbol MY ( port) : NC (normally

More information

Series CRQ2. Compact Rotary Actuator. Piping can be installed from one end. Body can be used as a flange Compact design saves mounting space

Series CRQ2. Compact Rotary Actuator. Piping can be installed from one end. Body can be used as a flange Compact design saves mounting space Compact Rotary Actuator Series CR2 Rack Pinion Style/:,,,, Piping can be installed from one end Uses internal cushioning, : Rubber bumper,, : Air cushion Angle adjustment bolts are standard Use of double

More information

Process Valve/Series VN

Process Valve/Series VN For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series VNA For controlling pneumatic

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Air Filter. Best Pneumatics 4. Equipment. Air Line

Air Filter. Best Pneumatics 4. Equipment. Air Line est Pneumatics Air Filter Air Filter: AF000 to 6000 P..- Mist Separator: AFM000/000/00 P..-6 Micro Mist Separator: AF000/000/00 P..-9 Large Flow Air Filter: AF00/0 P..- Air Line Equipment.-0 Modular Style

More information

Mini Free Mount Cylinder

Mini Free Mount Cylinder Mini Free Mount Cylinder Series ø, ø, ø, ø, ø, ø1, ø Series 1 ction Stroke 1 2 0 0 0 Clean uto switch series None Rod end Male threaded Without thread Solid state switch D-F D-M9 D-M9 W Female threaded

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

PD3/PDV3-20A/25A/40A Series

PD3/PDV3-20A/25A/40A Series Pilot operated 2-port valve for dust collector control (Large port size dust collector valve) PD3/PDV3-20A/25A/40A Series Air operated/with solenoid valve Port size: Rc3/4, Rc1, : Rc1 1 /2-: φ48, Rc1 1

More information

MULTIFUNCTION SPOOL VALVES air operated and solenoid air operated G3/4-G1 - ISO 5599/1 subbase-mounted body

MULTIFUNCTION SPOOL VALVES air operated and solenoid air operated G3/4-G1 - ISO 5599/1 subbase-mounted body MULTIFUNCTION SPOOL VALVES air operated and air operated G/-G - ISO 99/ subbase-mounted body /-/ Series Type ISO size MULTIFUNCTION Multifunction selector The multifunction selector is equipped with pilot

More information

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance! New Products Compact Pilot Operated Solenoid Valve for Water FWD Series New Product COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER Lightweight and large flow rate, low power consumption Improved corrosion

More information

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure Miniature Regulator Series ARJ1020F 2 Construction/Dimensions Lock nut M8 X 0.75 Panel screw Panel mounting hole Precautions Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety

More information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle

More information

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04 Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Related Products VR4151/4152 Relay Valve

Related Products VR4151/4152 Relay Valve Related Products VR4151/4152 Relay Valve Appropriate output sequences are affected according to the signal received from the machanical valve. Specifications 1 Fluid Air Operating pressure 0 to 1.0MPa

More information

: 660 N. For material handling and clamping of small workpieces. CKZT25 -X2797 (Base Type) Power Clamp Cylinder INFORMATION. ø

: 660 N. For material handling and clamping of small workpieces. CKZT25 -X2797 (Base Type) Power Clamp Cylinder INFORMATION. ø For material handling and clamping of small workpieces INFORMATION Power Clamp Cylinder ø25 Compact Type 34 mm Lightweight Compact High clamping force Lock function 53 mm Lightweight Weight : 580 g Compact

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model. Speed Controller with Uni One-touch Fitting Push-lock type Series Elbow Universal Brass New-stand male threads for piping that reduces the screw-in time by 1/3. Gasket Female thread Rc, G NP, NPF Shape

More information

MULTI SLIDERS CONTENTS

MULTI SLIDERS CONTENTS CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG CONTENTS Features 923 Handling Instructions and Precautions 925 Specifications 929 Order Codes 930 Inner Construction 931 Dimensions 932

More information

Series AN /Series AMC

Series AN /Series AMC s/exhaust Cleaner / Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0- Compact type

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP Micro Ejector Order Codes Manifold Order Codes Micro ejector single unit (without solenoid valve) ME Body model nozzle diameter : Maximum flow rate on vacuum side 03 0.3 : 3.0R/min. [0.012in., 0.106ft.

More information

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow) Check Valve eries Check Valve AP64 P.149 Vacuum Generator Vacuum Generator Vacuum Generator Module Vacuum Generator Module Flow witch Flow witch Flow witch (For high flow) eries AP7 & 7 AP71 AP72 eries

More information

Compact direct acting precision regulator

Compact direct acting precision regulator direct acting precision Components preparation and pressure adjustment / unit CONTENTS Product introduction 68 Safety precautions 6 Discrete (RJB5) 6 Block manifold (MNRJB5) 66 Block configurations 6 Technical

More information

BASIC OPERATION PRINCIPLES OF BROEN HEADWORKS

BASIC OPERATION PRINCIPLES OF BROEN HEADWORKS BASIC OPERATION PRINCIPLES OF BROEN HEADWORKS 1 CONTENT BROEN WATER VALVES WITH A CERAMIC HEADWORK 3 BROEN WATER VALVES WITH A COMPRESS/RUBBER HEADWORK 4 BROEN VALVES FOR SPECIAL WATER 5 BROEN VALVES FOR

More information

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil Ionizer / with surface potential sensor Series IZS0 How to Order 00 0 00 00 Ionizer IZ S 0 0 Bar length Bar length 00 mm 0 mm mm 00 mm 00 mm Ionizer Made to Order Bar type Size Electrode needle material

More information

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Coolant Valve. VNC Series. Cylinder actuation by pilot air oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

Flow sensor for compressed air

Flow sensor for compressed air for compressed air PFD/PFK (display separate type ) Sensor / CONTENTS Product introduction 1432 Applications 1434 Safety precautions 1435 (PFD)display separate type 1440 Tester kit (PFK) 1446 Electric

More information

Specifications. Fluid Operating pressure range Proof pressure Operating temperature range Filtration Element proof pressure differential

Specifications. Fluid Operating pressure range Proof pressure Operating temperature range Filtration Element proof pressure differential Air Suction Filter Series ZFA Prevents vacuum equipment trouble due to airborne contaminants. The collected dust does not remain in the case. Dust is removed easily at the time the filter element is replaced.

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

How to Order 02 1/4. Thread type Nil Rc N NPT * * Semi-standard

How to Order 02 1/4. Thread type Nil Rc N NPT * * Semi-standard Filter Regulator IW Series Two types are available: adjustable set pressure type and fixed set pressure type. Low/High temperature and external parts copper-free types can be selected. Pressure gauge connecting

More information

Compact Rotary Actuator

Compact Rotary Actuator Compact Rotary ctuator CRQ2 Series Rack & Pinion Type/:,,,, : 17 mm : mm : 29 mm : 33 mm : 37 mm CR 2 CR1 MSU CRJ CR1 CRQ2 MSQ MSZ Rotation 360 type 360 CRQ2 MSQ MRQ Series Variations Page Rotating angle

More information

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8 Precision Cylinder Series, ø, ø6, ø, ø, ø, ø MXS Series Variations Model 8 Standard stroke (mm) 7 7 Rod end configuration Cushion Rubber bumper End lock Made to Order Rod Variable stroke/ through-hole

More information

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43 CAT.EUS- B -UK Free Mount Cylinder A space-saving air cylinder with multiple surfaces capable of direct mounting. Offered in many variations. Space-saving The multiple surface direct mounted rectangular

More information

Compact Rotary Actuator

Compact Rotary Actuator Compact Rotary ctuator Series Rack & Pinion Style/:,,,, : 17 mm : mm : 29 mm : 33 mm : 37 mm CR2 CRU2 CR1 MSU CRJ Rotation 360 type MSQ 360 MSZ MSQ MRQ Series Variations Page Rotating angle 80 to 0 170

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

Rectangular Multi-connector. No. of Connecting Tubes: 10, 20. Plate. Plug connector Socket connector PAT.PEND

Rectangular Multi-connector. No. of Connecting Tubes: 10, 20. Plate. Plug connector Socket connector PAT.PEND Rectangular Multi-connector Series KDM No. of Connecting Tubes: 10, RoHS Multi-connector is effective in saving labor for separate transportation of the panel and the machine, and for exchanging units

More information

Pressure Reducing Valve V782

Pressure Reducing Valve V782 Pressure Reducing Valve V General Function The V Pressure Reducing Valve reduces the pressure within the system to a pre-set value. By using the differential pressure, the pressure reducing valve adjusts

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication Hand Valve VH Series VH0 Specifications VH0 Fluid Proof pressure Max. operating VH00/00/00 pressure VH0 Ambient temperature and operating fluid temperature Operating angle Lubrication Air.5 MPa.0 MPa MPa

More information

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features

More information