1 Enclosed switches and safety switches Main Catalogue January 2009

2

3 Enclosed switches and safety switches Contents General description/technical data... 4 Ratings... 8 Switch-disconnectors / isolators Plastic enclosed side-operated switch-disconnectors / isolators Aluminum enclosed side-operated switch-disconnectors / isolators Aluminum enclosed front-operated switch-disconnectors / isolators Safety switches Plastic enclosed side-operated safety switches Aluminum enclosed side-operated safety switches Aluminum enclosed front-operated safety switches Fireman switch Aluminum enclosed side-operated switch-disconnectors - Fireman switch Pressure switch Pressure switch - TBE Accessories Auxiliary contacts, padlock Expander washer, cable tightening/glands, hose clamps, cable entries Dimensions Index

4 Advanced safety ABB is proud to present a new range of small enclosed switches which comply with IEC These switches have many different electrical mains applications, e.g. as main switches, switch-disconnectors, control switches, safety switches, fireman switches, etc. These products were developed with a focus on personal safety. A number of improvements have also been made in order to simplify installation work of the switches. The high level of quality guarantees a long and safe use. One of the most common uses for the new switches is as safety switches for servicing and maintenance work. A locally-positioned lockable switch in the immediate vicinity of the machinery where work is to be carried out ensures a safe working environment for maintenance staff. In larger premises, disconnecting a section of the premises locally may also be preferable in terms of accessibility, instead of disconnecting the entire premises using the main switch. Main switches which comply with the European standard for machinery According to EU Directive EN 60204, Standard for machinery, electrical equipment or machinery must be disconnected from the electrical supply during maintenance or repairs. In order to avoid unintentional or unauthorized start-ups, switch-disconnectors should be fitted to the supply circuits for machinery: - where a number of people work - which can be started from different places - which can be started automatically or by computer - which cannot be seen from the place where it is started - with complex control systems - where there is a significant risk of personal injury in the event of an undesired start-up The enclosed disconnector must not be used for starting and stopping or as an emergency stop device. Building on 30 years of experience ABB was quick to see the need for safe disconnection when servicing electrically-powered machinery, and has been active for many years in standardisation and product development within this field. ABB s first safety switch was designed 30 years ago, and has since been improved to give even better safety and greater resistance against various environmental stresses. The new range of safety switches has been designed and tested in accordance with Machinery Directive EN 60204, and has been adapted for use in the most common applications in industrial, public and residential environments. The switches can be installed both indoors and outdoors. Easy to install safe to use The new product range has been developed to bring benefits for both the installation engineer and the owner of the premises. Better access and simpler connection allow for faster, safer installation. Personal safety has been improved through measures such as the cover of the enclosure being interlocked so that it cannot be removed while the switch is in the on position. Even with the cover removed, the switch still features ingress protection (IP20), preventing accidental contact with live parts. The same applies to the neutral terminal. The new switches are available in plastic and aluminum enclosures, in 2, 3, 4 and 6 pole versions. 4

5 Plastic enclosed switch-disconnectors, side operated Degree of protection: IP 65, IEC Degree of protection without cover: IP 20, IEC Enclosure in PBT, UL94 V1, Glow wire 850 (IEC ) Resistance against UV-radiation: F 1, UL 746C Standard IEC for Switch-disconnectors European Standard EN60204 Safety of machinery Cable outlets M sized threaded knock-outs 2-, 3-, 4- and 6-pole versions Light grey/dark grey enclosure with gray handle Yellow enclosure have red handle Handle indication I-0/ON-OFF Suitable for 3-, 4- and 5-wire systems Easy to install Easy to mount Metric threaded knockouts Knockout in the back of the box Isolated neutral terminal with separated in/out connection. Option for auxiliary contacts, (N.O./N.C.) Handle padlockable in O position as standard. Knockout for padlock in I position. Shackle for 6 padlocks Handle, axis and switch insert is one system factory assembled. Switch insert UL94 V0 and glow wire 960 (IEC ) Knockout for ventilation. Water drain holes IP 54 cable glands sealing plugs included Cable strip length Terminals for 5-wire system: three phases + N + PE terminals 5

6 Enclosed switches and safety switches ABB offers a complete range of enclosed switches and safety switches covering the range I th A, I e A, for utilization category AC 23A at U e V. Isolation voltages up to 1000 V. The ABB Cewe-Control switches comply with IEC and IEC The range includes: Type BW: plastic enclosed switchdisconnectors/isolators Type BWS: plastic enclosed safety switches Type KSE: aluminum enclosed switch-disconnectors/isolators Type LBAS: aluminum enclosed safety switches Special applications: Type KSF: fireman switch Type TBE: pressure switch The BW and BWS type enclosed switches / safety switches have enclosures made in impact resistant platic material. The KSE, KSF and LBAS types have enclosures made in aluminum alloy (silumin). The Enclosures are available in different colors such as grey, yellow and white. Safety switches For extra safety in motor applications it is common practice to connect the safety switch to the device controlling the motor with a signal cable and an auxillary contact. All safety switches comes with a Normally Open auxiliary contact with 20ms early break, late make as standard. It is also possible to upgrade any enclosed switch with an extra auxiliary contact. A complete range of accessories such as auxiliary contacts, neutral terminals and cable glands are available. The plastic enclosed switches and safety switches up to I e 75 A are also available in 6 pole versions. Installation of switches BW, KSE and safety switches BWS, LBAS Example of single line diagrams Switch Safety switch Motor Direct start 6 6 Y/D Motor starter Safety switch 6-poles Motor Y/D Motor starter Switchgear or installation board 3 3 Safety switch 3-poles 3 3 Safety switch 3-poles Safety switch Safety switch Safety switch 1) Motor Air conditioning Equipment Pump Ie AC A Y/D-start Ie AC A Y/D-start All kinds of electrical equipment 1) When two or more cables supply a motor or piece of equipment and several safety switches are installed, a label must be provided explaining the need to switch off all safety switches before maintenance or repair. 6

7 Application Typical examples of applications for ABB s enclosed switches include in air-conditioning and cooling systems, fans, lifts, conveyor belts, washing machines, restaurant kitchens and various industrial production facilities. Dust, running water, chemicals, UV radiation, mechanical damage, etc., can cause significant environmental stress, which ABB s enclosed switches can cope with easily. The plastic enclosure is made from hardwearing PBT plastic (VALOX ) that complies with UL 94 V1 and has been glowwire tested to 850 C in accordance with IEC The metal enclosure is produced in coated aluminum alloy (Silumin), making it suitable for all in-/outdoor environments, from mountain areas to deserts. The switches are also available in ATEX category 3 (zone 22) versions for use in environments where there is a risk of explosion. 7

8 Enclosed switches Ratings IEC Switches type BW and KSE Safety switches type BWS and LBAS Plastic and metal enclosure I e AC23A A I th A For motors P e up to 45 kw U e V Degree of protection: IP54 or IP65 BW225 DP BW325 L BW325W BW240 DP BW340 KSE363 KSE380 KSE3100 BW225 W DP BW325 KS 240 DP BW440 KSE463 KSE480 KSE225 DP BW325 K BW640 LBAS336 LBAS363 KSF225 DP BW425 KSE340 BW325Y KSE440 BW625 BWS325 KSE325 BWS425 KSE425 BWS625 BWS316 BWS325Y BWS416 BWS425Y BWS616 BWS625Y BWS316Y LBAS325 BWS416Y LBAS425 BWS616Y KSF 340 BWS316F KSF 440 LBAS316 LBAS416 KSF 325 KSF 425 Isolation voltage V Uimp V Rated thermal current lthe at 40ºC A lthe at 60ºC A With minimum conductor mm cross section Operating voltage, Ue V Rated current le AC23A A le AC22A A Max fuse, am A Conditional short-circuit current ka Fuse protected shortcircuit making capacity ka Rated making capacity 100A cos = 0,45 A Rated breaking capacity 100A cos = 0,45 A Max motor power kw 7, Terminals for cable section Cu mm² Earth terminal mm²

9 Switches type KSE Safety switches type LBAS ( 125A) Metal enclosure (aluminum alloy) I e AC23A A I th A For motors P e up to 355 kw U e V Degree of protection: IP65 KSE3160 LBAS160/S KSE3250 KSE3315 KSE3500 KSE3630 LBAS125/S LBAS160/SK 1) LBAS200/S LBAS250/S LBAS400/S LBAS630/S LBAS125/SK 1) Isolation voltage V Uimp kv Rated thermal current lthe A Operating voltage, Ue V Rated current le AC23A A Max fuse A Conditional short-circuit current ka Fuse protected shortcircuit making capacity ka Rated making capacity 100A cos = 0,45 > 100A cos = 0,35 A Rated breaking capacity 100A cos = 0,45 > 100A cos = 0,35 A Max motor power kw Terminals for cable ) 2) 2) 2) 2) section Cu mm² or 1) or 1 Earth terminal mm² x300 2x300 2x300 2x300 Expander washes for Included Included Included Included Included Included safety protection in case of short-circuit 1) Terminal screw for cable lugs. (M8) 2) Terminal screw for cable lugs. (M12) 9

10 Enclosed switches Ordering information 10 BW225 DP, BW325 TPN BW425 TPSN BW225 W DP, BW325 W TPN BW325 Y DP BW325 K TPN BW325 L TPN BW240 DP, BW340 TPN, BW440 TPSN BW625 TPN, BW640 TPN 2CMC341011F0066 2CMC341011F0056 2CMC341011F0073 2CMC341011F0072 2CMC341011F0060 2CMC341011F0054 2CMC341011F0054 Brand: Cable entries: Lockable: Ratings: See page 8 Dimensions: See page 21 Degree of protection: IP 65 Robust thermoplastic (PBT) ABB Metric threaded knock-outs or knock-outs. Membrane glands/ sealing plugs (IP 54) are included. When IP 65 degree of protection is required compression glands must be used. Yes Neutral and PE terminal: Included Auxiliary contacts: Not included Colors Light grey Handle and cover: Dark grey (except for * and **) Plastic enclosed side-operated switch-disconnectors, 2-pole current [A] Up/down [mm] [kg] AC-22A AC-23A W H D 230V 400V 400V xM25/2xM BW225 DP 2CMA142400R xM25/2xM BW225 W DP *) 2CMA142401R xM32/2xM32+1xM BW240 DP 2CMA142407R Plastic enclosed side-operated switch-disconnectors, 3-pole current [A] Up/down [mm] [kg] AC-22A AC-23A W H D 400V 500V 690V 500V xM25/2xM BW325 TPN 2CMA142403R xM25/2xM BW325 W TPN *) 2CMA142402R xM25/2xM BW325 Y TPN **) 2CMA142441R xM25/2xM BW325 K TPN *) 2CMA142443R xM32/ BW340 TPN 2CMA142408R xM32+1xM16 Plastic enclosed side-operated switch-disconnectors, 3-pole current [A] Up/down [mm] [kg] AC-22A AC-23A W H D 400V 500V 690V 400V xM25/2xM BW325 L TPN *) 2CMA142404R Plastic enclosed side-operated switch-disconnectors, 4-pole current [A] Up/down [mm] [kg] AC-22A AC-23A W H D 400V 500V 690V 500V xM25/2xM BW425 TPSN 2CMA142405R xM32/2xM32+1xM BW440 TPSN 2CMA142409R Plastic enclosed side-operated switch-disconnectors, 6-pole current [A] Up/down [mm] [kg] AC-22A AC-23A 400V 500V 690V 500V W H D xØ25+1xØ BW625 TPN 2CMA142406R xØ25+1xØ xØ25+1xØ BW640 TPN 2CMA142410R xØ25+1xØ16 *) Light grey box and cover, dark grey handle **) Light grey box, yellow cover, red handle

11 Enclosed switches Ordering information KSE225 DP, KSE325 TPN, KSE425 TPSN KSE240 DP, KSE340 TPN, KSE440 TPSN 2CMC342002F0008 2CMC342002F0010 Brand: Cable entries: Lockable: Ratings: See page 8 Dimensions: See page 21 Degree of protection: IP 65 Neutral and PE terminal: Auxiliary contacts: Colors Handle and cover: Aluminum alloy - (PBT Handle) ABB Metric threaded holes with membrane glands/sealing plugs (IP 54) included. When IP 65 degree of protection is required compression glands must be used. Yes Included Not included Light grey Dark grey Aluminum enclosed side-operated switch-disconnectors, 2-pole Cable entries from top and bottom AC-22A AC-23A W H D 230V 400V 400V xM25/2xM KSE225 DP 2CMA142411R xM32/2xM32+1xM KSE240 DP 2CMA142414R Aluminum enclosed side-operated switch-disconnectors, 3-pole Cable entries from top and bottom AC-22A AC-23A W H D 400V 500V 690V 500V xM25/2xM KSE325 TPN 2CMA142412R xM32/2xM32+1xM KSE340 TPN 2CMA142415R Aluminum enclosed side-operated switch-disconnectors, 4-pole Cable entries from top and bottom AC-22A AC-23A W H D 400V 500V 690V 500V xM25/2xM KSE425 TPSN 2CMA142413R xM32/2xM32+1xM KSE440 TPSN 2CMA142416R

12 Enclosed switches Ordering information KSE363 TPN, KSE380 TPN, KSE3100 TPN 2CMC341011F0078 Brand: Cable entries: Lockable: Ratings: See page 8 Dimensions: See page 22 Degree of protection: IP 65 Neutral and PE terminal: Auxiliary contacts: Colors Cover: Handle: Aluminum alloy - (PBT Handle) ABB Metric threaded holes with membrane glands/sealing plugs (IP 54) included. When IP 65 degree of protection is required compression glands must be used. Yes Included Not included Light grey Dark grey Black Aluminum enclosed front-operated switch-disconnectors, 3-pole Cable entries from top and bottom KSE363 D/TPN 2CMC341011F0075.r AC-22A AC-23A W H D 500V 690V 500V xM40/2xM40+1xM KSE363 TPN 2CMA144580R xM40/2xM40+1xM KSE380 TPN 2CMA144583R xM40/2xM40+1xM KSE3100 TPN 2CMA144585R Cable entries from bottom current [A] Down [mm] [kg] AC-22A AC-23A W H D 500V 690V 500V xM40+1xM KSE363 D/TPN 2CMA144581R KSE463 TPSN, KSE480 TPSN 2CMC341011F0078 Aluminum enclosed front-operated switch-disconnectors, 4-pole Cable entries from top and bottom AC-22A AC-23A W H D 500V 690V 500V xM40/2xM40+1xM KSE463 TPSN 2CMA144582R xM40/2xM40+1xM KSE480 TPSN 2CMA144584R

13 Enclosed switches Ordering information KSE3160 2CMC341011F0023 Aluminum alloy - (PBT Handle) Brand: CEWE Cable entries: Cable tightening/glands included Lockable: Yes Ratings: See page 9 Dimensions: See page 22 Degree of protection: IP 65 Neutral and PE terminal: Included Auxilary contact: Not included Colours Handle and cover: White Black and red Aluminum enclosed front-operated switch-disconnector, 3-pole Cable entries from bottom KSE3250, KSE3315, KSE3500, KSE3630 2CMC341011F0084 AC-22A AC-23A W H D 690V 400V xØ KSE3160 2CMA144712R xØ KSE3250 1) 2CMA144713R xØ KSE3315 2) 2CMA144714R xØ KSE3500 2) 2CMA144715R xØ KSE3630 2) 2CMA144716R ) Terminal screw for cable lugs. (M12) max 2//240mm 2 2) Terminal screw for cable lugs. (M12) max 2//300mm 2 13

14 Safety switches Ordering information BWS316 TPN, BWS416 TPSN BWS316 Y TPN, BWS416 Y TPSN BWS325 TPN, BWS425 TPSN BWS325 Y TPN, BWS425 Y TPSN BWS616 TPN, BWS625 TPN 2CMC341011F0055 2CMC341011F0054 2CMC341011F0070 2CMC341011F0066 2CMC341011F0060 2CMC341011F0056 Brand: Cable entries: Lockable: Ratings: See page 8 Dimensions: See page 21 Degree of protection: IP 65 Neutral and PE terminal: Included Auxiliary contact: Included (1 NO) Colors Light grey Handle and cover: Dark grey. (Except for *) ) Robust thermoplastic (PBT) ABB Metric threaded knock-outs. Membrane glands/sealing plugs (IP 54) are included. When IP 65 degree of protection is required compression glands must be used. Yes Plastic enclosed side-operated switch-disconnector, 3-pole AC-23A AC-23A W H D 500V 690V Kwh ,5 2xM25/2xM BWS316 TPN 2CMA142417R xM32/2xM32+1xM BWS325 TPN 2CMA142420R ,5 2xM25/2xM BWS316 Y TPN *) 2CMA142423R xM32/2xM32+1xM BWS325 Y TPN *) 2CMA142426R ,5 2xM25/2xM BWS316 F TPN **) 2CMA142440R Plastic enclosed side-operated switch-disconnectors, 4-pole AC-22A AC-23 W H D 500V 690V Kwh ,5 2xM25/2xM BWS416 TPSN 2CMA142418R xM32/2xM32+1xM BWS425 TPSN 2CMA142421R ,5 2xM25/2xM BWS416 Y TPSN *) 2CMA142424R xM32/2xM32+1xM BWS425 Y TPSN *) 2CMA142427R Plastic enclosed side-operated switch-disconnectors, 6-pole AC-22A AC-23 W H D 500V 690V Kwh ,5 2xØ25+Ø16/2xØ25+Ø BWS616 TPN 2CMA142419R xØ25+Ø16/2xØ25+Ø BWS625 TPN 2CMA142422R ,5 2xØ25+Ø16/2xØ25+Ø BWS616 Y TPN *) 2CMA142425R xØ25+Ø16/2xØ25+Ø BWS625 Y TPN *) 2CMA142428R *) Light grey box, yellow cover, red handle **) Auxiliary contact not included BWS616 Y TPN BWS625 Y TPN 14

15 Safety switches Ordering information LBAS316 TPN, LBAS416 TPSN 2CMC342002F0008 Brand: Cable entries: Lockable: Ratings: See page 8 Dimensions: See page 21 and 22 Degree of protection: IP 65 Neutral and PE terminal: Included Auxiliary contacts: Included (1 NO) Colours Light grey Handle and cover: Dark grey (Except for *) ) Aluminum alloy - (PBT Handle) ABB Metric threaded holes with membrane glands/sealing plugs (IP 54) included. When IP 65 degree of protection is required compression glands must be used. Yes LBAS325 TPN. LBAS425 TPSN 2CMC342002F0010 Aluminum enclosed side-operated switch-disconnector, 3-pole Cable entries from top and bottom AC-22A AC-23 W H D 500V 690V Kwh ,5 2xM25/2xM LBAS316 TPN 2CMA142430R xM32/2xM32+1xM LBAS325 TPN 2CMA142432R CMC341011F0075 LBAS336 M/TPN. LBAS363 M/TPN Aluminum enclosed side-operated switch-disconnectors, 4-pole Cable entries from top and bottom AC-22A AC-23 W H D 500V 690V Kwh ,5 2xM25/2xM LBAS416 TPSN 2CMA142431R xM32/2xM32+1xM LBAS425 TPSN 2CMA142433R Aluminum enclosed front-operated switch-disconnector, 3-pole Cable entries from top and bottom AC-22A AC-23 W H D 500V 690V Kwh xM40/2xM40+1xM LBAS336 M/TPN *) 2CMA144635R xM40/2xM40+1xM LBAS363 M/TPN *) 2CMA144636R *) Light grey box, dark grey cover, black handle 15

16 Safety switches Ordering information LBAS125/S, LBAS125/SK, LBAS160/S, LBAS160/SK 2CMC341011F0023 Aluminum alloy - (PBT Handle) Brand: Cewe Cable entries: Cable tightening/glands included Lockable: Yes Ratings: See page 9 Dimensions: See page 22 Degree of protection: IP 65 Neutral terminal: Not included PE terminal: Included Auxiliary contacts: Included (1 NO) Colours White Handle and cover: Black and red Aluminum enclosed front-operated switch-disconnector, 3-pole Cable entries from bottom LBAS200/S, LBAS250/S LBAS400/S, LBAS630/S 2CMC341011F0084 current [A] Down [mm] [kg] AC-23A W H D 400V 500V 690V xØ LBAS125/S 2CMA144495R xØ LBAS125/SK 1) 2CMA144496R xØ LBAS160/S 2CMA144498R xØ LBAS160/SK 1) 2CMA144499R xØ LBAS200/S 2) 2CMA144500R xØ LBAS250/S 3) 2CMA144503R xØ LBAS400/S 3) 2CMA144505R xØ LBAS630/S 3) 2CMA144506R ) Screw terminals for cable lugs max 95 mm 2 2) Screw terminals for cable lugs max 2//240 mm 2 3) Screw terminals for cable lugs max 2//300 mm 2 - Extra auxiliary contacts to be ordered separately, see page

17 Enclosed switches - Fireman switch Ordering information KSF225 DP, KSF325 TPN, KSF325 NO/TPN, KSF425 TPSN KSF340 TPN, KSF440 TPSN 2CMC342002F0012 2CMC342002F0013 General Technical Data Aluminum alloy Brand: ABB Degree of protection: IP 65 Lockable: Yes Ratings: See page 8 Dimensions: See page 22 Auxiliary contact: Included (1 NO) Colors Red Handle and cover: Red Standards Devices complying with - International standards IEC Brittish standards BS7671 (Requirements for electrical installations) Aluminum enclosed side-operated switch-disconnectors, 2-pole Cable entries from top and bottom AC-22A W H D 230V 400V xM25/2xM KSF225 DP 2CMA142435R Aluminum enclosed side-operated switch-disconnectors, 3-pole Cable entries from top and bottom AC-22A W H D 400V 500V 690V xM25/2xM KSF325 TPN 2CMA142436R xM32/2xM32+1xM KSF340 TPN 2CMA142438R xM25/2xM KSF325 NO/TPN*) 2CMA142442R Aluminum enclosed side-operated switch-disconnectors, 4-pole Cable entries from top and bottom Rated operational Cable entries Enclosue size Type Order number Weight AC-22A W H D 400V 500V 690V xM25/2xM KSF425 TPSN 2CMA142437R xM32/2xM32+1xM KSF440 TPSN 2CMA142439R *) Auxiliary contact included. 17

18 Pressure switch - TBE 3 Ordering information 2CMC306006F0001 Enclosure Bottom: Cover: Brand: Terminals: 2.5 mm 2 Rated current: 10A (IEC ) Degree of protection: IP 44 Aluminum alloy Transparent polycarbonate All essential parts in non corrosive material Cewe TBE 3 Area of use Pressure switch TBE 3 used for pressure control of air or water systems. Pressure range up, to 800 kpa. (8 kp/cm 2 ). Making and breaking pressure Making and breaking pressures adjustable on two separate scales. Making from 100 to 600 kpa (1 to 6 kp/cm 2 ). Breaking pressure adjustable from 200 to 800 kpa (2-8 kp/cm 2 ). Minimum difference 200 kpa (2 kp/cm 2 ). Rated voltage Cable entries Pipe Enclosure size Type Order number Weight V Down entries [mm] [kg] 0000 W H D 400 2xM20 R 1/2" TBE 3 2CMA144551R

19 Accessories Auxiliary contact block Order Code Type 1) For switch type 1-pole making 10 A, 690 V 1SFA611610R1001 MCB-10 KSE , BE and BW325, 340, 625 MCB-01 MCB-10 1-pole breaking 10 A, 690 V 1SFA611610R1010 MCB-01 KSE , BE and BW325, 340, pole making 10 A, 690 V 2CMA144690R1000 OA1G10 KSE363, KSE380, KSE463, KSE480, KSEE3100, KSE pole breaking 10 A, 690 V 2CMA144691R1000 OA1G01 KSE363, KSE380, KSE463, KSE480, KSEE3100, KSE4100 OA 1G10 OA 1G01 1-pole making 10 A, 690 V 2CMA144519R1000 OBEA 10 KSE3160, KSE3250, LBAS 125/S 160/S 1-pole breaking 10 A, 690 V 2CMA144520R1000 OBEA 01 KSE3160, LBAS125/S 160/S OBEA 10 OBEA 01 2-pole making/breaking for galvanically separated circuits, 10 A, 690 V 2CMA144521R1000 OZXK 12 KSE3315, KSE3250, LBAS200/S, LBAS250/S 2CMA144522R1000 OZXK 1 KSE3500, KSE3630, LBAS400/S, LBAS630/S 1) In all sizes of safety switches there is space for one more auxiliary contact block than included. In the KSE types there is space for 1 contact block (not included) Ratings for auxiliary contact For switch 25-40A A For safety switch 16-25A 45-75A A A OZXK 12 OZXK 1 IEC IEC IEC IEC Rated thermal current A Duty category AC 12 AC 15 AC 12 AC 12 Operating voltage V 690, 400, , 400, , 400, , 400, 240 Rated current A Padlock unit suitable for all switches Order Code Type Description L6 2CMA144539R1000 L6 Shackle for up to 6 padlocks Mounting / spacer feets Order Code 2CMA170052R1000 Description Mounting / spacer feets 19

20 Accessories Accessories, LBAS Expander washer for LBAS125/S 160/S (K) Expander tube for LBAS200/S 630/S Cable tightening/gland for LBAS125/S 160/S (K) Cable tightening/gland for LBAS200/S 630/S Hose clamp, stainless steel, for list no Hose clamp, stainless steel, for list no Neutral terminals for LBAS Order Code Type Description For switches type CMA144534R1000 NOLS1 Neutral terminal LBAS125/S 160/S (K) 2CMA144535R1000 NOLS2 Neutral terminal LBAS200/S 630/S Cable entries/sealing plugs for switches type KSE, Safety switches type KSA and LBAS and KSEE Membrane glands/sealing plugs (IP 54) in thermoplastic are included as follows: 1) Type Cable entries size No of pcs. 2) For cable diam. (mm) +M/TPN M threads 1) incl. IP 54 Membrane gland-sealing plug KSE M M KSE M M KSE M M KSE M M KSEE M M KSA M M KSA M M LBAS M M LBAS M M ) The types specified can be used both as cable tightening and as sealing plug. 2) The cable hole of the membrane gland has to be cut carefully in order to reach the IP 54 degree of protection. If IP 65 degree of protection is requested compression glands must be used. 20

21 Enclosed switches Dimension drawings Plastic enclosed side-operated switch-disconnectors / safety switches X W A ØG Type Size Cable entry Fixing dimensions W H D X Y A B G 2-pole, Plastic enclosed side-operated switch-disconnectors BW xM H B BW xM32 1xM pole, Plastic enclosed side-operated switch-disconnectors BW xM BW xM32 1xM Y X D 3-pole, Plastic enclosed side-operated safety switches BWS xM BWS xM32 1xM pole, Plastic enclosed side-operated switch-disconnectors BW xM W BW xM32 1xM Y X 4-pole, Plastic enclosed side-operated safety switches BWS xM BWS xM32 1xM pole, Plastic enclosed side-operated switch-disconnectors BW xø25 ø H BW xø25 ø pole, Plastic enclosed side-operated safety switches BWS xø25 ø Y X D BWS xø25 ø A ØG B Aluminum enclosed side-operated switch-disconnectors / safety switches W Type Size Cable entry Fixing dimensions W H D X Y A B G X A ØG 2-pole, Aluminum enclosed side-operated switch-disconnectors KSE xM KSE xM32 1xM pole, Aluminum enclosed side-operated switch-disconnectors H B KSE xM KSE xM32 1xM pole, Aluminum enclosed side-operated safety switches LBAS xM Y X D LBAS xM32 1xM pole, Aluminum enclosed side-operated switch-disconnectors KSE xM KSE xM32 1xM pole, Aluminum enclosed side-operated safety switches LBAS xM LBAS xM32 1xM

22 Enclosed switches Dimension drawings Aluminum enclosed front-operated switch-disconnectors / safety switches X W A ØG Type Size Cable entry Fixing dimensions W H D X Y A B G H Y X D B 3-pole, Aluminum enclosed front-operated switch-disconnectors KSE xM40 1xM KSE xM40 1xM KSE xM40 1xM pole, Aluminum enclosed front-operated safety swithes LBAS xM40 1xM LBAS xM40 1xM pole, Aluminum enclosed front -operated switch-disconnectors KSE xM40 1xM KSE xM40 1xM Aluminum enclosed front-operated switch-disconnectors / safety switches D W Type Size Cable entry Fixing dimensions H W D X A B C min/max min/max H 3-pole, Aluminum enclosed front-operated switch-disconnectors KSE xØ / /405 8 KSE 3250/ xØ / / KSE3500/ xØ / / pole, Aluminum enclosed front-operated safety switches LBAS 125/ xØ / /405 8 LBAS 200/ xØ / / LBAS 400/ xØ / / X W D A øc H B X Aluminum enclosed side-operated switch-disconnectors - Fireman switch X W A ØG Type Size Cable entry Fixing dimensions W H D X Y A B G H Y X D B 2-pole, Aluminum enclosed side-operated switch-disconnectors KSF xM pole, Aluminum enclosed side-operated switch-disconnectors KSF xM KSF xM32 1xM pole-aluminum KSF xM KSF xM32 1xM

23 Enclosed switches Index Type Order number Page Discription Accossories LBAS Expander washer Accossories LBAS Expander tube Accossories LBAS Cable tightening/gland Accossories LBAS Cable tightening/gland Accossories LBAS Hose clamp Accossories LBAS Hose clamp BW225 DP 2CMA142400R Enclosed switch BW225 W DP 2CMA142401R Enclosed switch BW240 DP 2CMA142407R Enclosed switch BW325 K TPN 2CMA142443R Enclosed switch BW325 L TPN 2CMA142404R Enclosed switch BW325 TPN 2CMA142403R Enclosed switch BW325 W TPN 2CMA142402R Enclosed switch BW325 Y TPN 2CMA142441R Enclosed switch BW340 TPN 2CMA142408R Enclosed switch BW425 TPSN 2CMA142405R Enclosed switch BW440 TPSN 2CMA142409R Enclosed switch BW625 TPN 2CMA142406R Enclosed switch BW640 TPN 2CMA142410R Enclosed switch BWS316 F TPN 2CMA142440R Safety switch BWS316 TPN 2CMA142417R Safety switch BWS316 Y TPN 2CMA142423R Safety switch BWS325 TPN 2CMA142420R Safety switch BWS325 Y TPN 2CMA142426R Safety switch BWS416 TPSN 2CMA142418R Safety switch BWS416 Y TPSN 2CMA142424R Safety switch BWS425 TPSN 2CMA142421R Safety switch BWS425 Y TPSN 2CMA142427R Safety switch BWS616 TPN 2CMA142419R Safety switch BWS616 Y TPN 2CMA142425R Safety switch BWS625 Y TPN 2CMA142428R Safety switch BWS626 TPN 2CMA142422R Safety switch Type Order number Page Discription KSF325 NO/TPN 2CMA142442R Fireman enclosed switch KSF325 TPN 2CMA142436R Fireman enclosed switch KSF340 TPN 2CMA142438R Fireman enclosed switch KSF425 TPSN 2CMA142437R Fireman enclosed switch KSF440 TPSN 2CMA142439R Fireman enclosed switch L6 2CMA144539R Shackle LBAS125/S 2CMA144495R Safety switch LBAS125/SK 2CMA144496R Safety switch LBAS160/S 2CMA144198R Safety switch LBAS160/SK 2CMA144489R Safety switch LBAS200/S 2CMA144500R Safety switch LBAS250/S 2CMA144503R Safety switch LBAS316 TPN 2CMA142430R Safety switch LBAS325 TPN 2CMA142432R Safety switch LBAS336 M/TPN 2CMA144635R Safety switch LBAS363 M/TPN 2CMA144636R Safety switch LBAS400/S 2CMA144505R Safety switch LBAS416 TPSN 2CMA142431R Safety switch LBAS425 TPSN 2CMA142433R Safety switch LBAS630/S 2CMA144506R Safety switch MCB-01 1SFA611610R Auxiliary contact MCB-10 1SFA611610R Auxiliary contact OA1G01 2CMA144691R Auxiliary contact OA1G10 2CMA144690R Auxiliary contact OBEA01 2CMA144520R Auxiliary contact OBEA10 2CMA144519R Auxiliary contact OZXK1 2CMA144522R Auxiliary contact OZXK12 2CMA144521R Auxiliary contact TBE 3 2CMA144551R Pressure switch Cable entries/sealing plug 20 Accessories KSE225 DP 2CMA142411R Enclosed switch KSE240 DP 2CMA142414R Enclosed switch KSE3100 TPN 2CMA144585R Enclosed switch KSE3160 2CMA144712R Enclosed switch KSE325 TPN 2CMA142412R Enclosed switch KSE3250 2CMA144713R Enclosed switch KSE3315 2CMA144714R Enclosed switch KSE340 TPN 2CMA142415R Enclosed switch KSE3500 2CMA144715R Enclosed switch KSE363 D/TPN 2CMA144581R Enclosed switch KSE363 TPN 2CMA144580R Enclosed switch KSE3630 2CMA144716R Enclosed switch KSE380 TPN 2CMA144583R Enclosed switch KSE425 TPSN 2CMA142413R Enclosed switch KSE440 TPSN 2CMA142416R Enclosed switch KSE463 TPSN 2CMA144582R Enclosed switch KSE480 TPSN 2CMA144584R Enclosed switch KSF225 DP 2CMA142435R Fireman enclosed switch 23

24 ABB AB Cewe-Control Box 1005, SE Nyköping, Sweden Telephone Telefax Catalogue January 2009, Rev A Prod. ABB AB, Cewe-Control/XM Copyright ABB AB

Enclosed Switches and Safety Switches

Enclosed Switches and Safety Switches Enclosed Switches and Safety Switches Enclosed Switches and Safety Switches Contents General information... 2 Description... 5 Ratings... 8 Plastic enclosed switches and safety switches...11 Metal enclosed

More information

Low Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201

Low Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201 Low Voltage Products Enclosed switches Brochure OT_KSE 1 GB 05_02 O I N O SafeLine OF F 2 I Enclosed switches Contents: General... 4 Technical data... 5 Switches in plastic enclosure General... 6 Ordering

More information

The complete offer Enclosed switch-disconnectors / Isolators

The complete offer Enclosed switch-disconnectors / Isolators June 2009 The complete offer Enclosed switch-disconnectors / Isolators May 29, 2009 Slide 1 Contents Why use enclosed switch-disconnectors Applications and application demands The ABB products and features

More information

Breakers and Switches. Enclosed switches Safety switches A

Breakers and Switches. Enclosed switches Safety switches A Breakers and Switches Enclosed es Safety es 16...1250 A Safety es From 16...1250 Amperes Contents 04 Product overview, features 10 Technical data, cabling 14 Safety es, ordering information 14 Plastic

More information

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories

More information

Catalog. Industrial Plugs & Sockets

Catalog. Industrial Plugs & Sockets Catalog Industrial Plugs & Sockets Contents Page Introduction... 4 IEC 60309-2 (clock)... 5 Product overview Critical & Safe... 6 Tough & Safe... 7 Easy & Safe... 8 Plugs... 10 Connectors... 13 Switched

More information

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution

More information

Commando Safetyswitch

Commando Safetyswitch 80 Commando Safetyswitch Commando Safetyswitches are manufactured from Polybutylene Terephthalate (PBT) for maximum impact resistance. The range offers a selection of IP54 and IP65 ratings to cover a variety

More information

AC Switches: ML & MN Series DC Switches: MDC1A Series

AC Switches: ML & MN Series DC Switches: MDC1A Series AC Switches: ML & MN Series DC Switches: MDC1A Series Australian & New Zealand Distributor Leveltec Engineering Pty Ltd Gloucester P:+612 6558 9264 F:+612 6558 1002 Sydney P:+612 9299 5630 F:+612 6558

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Low Voltage Products. Breakers and Switches for the HVAC segment

Low Voltage Products. Breakers and Switches for the HVAC segment ow Voltage Products Breakers and witches for the VAC segment ABB s extensive range of products for the VAC segment ABB s very extensive range of appliances and systems for low voltage power distribution

More information

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA ENCLOSED SWITCHES SAFETY SWITCHES / ISOLATORS 16-800A TECHNICAL DATA Safety switches / isolators 10A 16A 25A 40A 63A 80A 125A 160A 200A 250A 315A 400A 630A 800A Rated Insulation voltage Ui (V) 690 690

More information

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Overcurrent releases - description, specifications, characteristics specifications specifications description... BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

Empty enclosures IEC 62208

Empty enclosures IEC 62208 374 www.hensel-electric.de/en in accordance with for customized solutions and individual applications for example for low-voltage switchgear and controlgear assemblies i n accordance with the IEC 61439-series

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

IP44 - IP66 Rated RCD, Power & Cable Management

IP44 - IP66 Rated RCD, Power & Cable Management IP44 - IP66 Rated RCD, Power & Cable Management IP54 Rated 10 amp Switches IP66 Rated 10 amp Switches IP66 Rated 13 amp Sockets IP66 13 amp RCD switched Socket IP66 13 amp unswitched socket with timer

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations Version:- 3.0 Date of Issue:- Dec 2013 Page 1 of 13 NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations 1. Purpose This document is the technical specification

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX 70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems MNS Light F Low-voltage switchgear with fixed units ABB LV Systems Cubicle design MNS Light F switchgear is a flexible system with a large selection of cubicle variants that can be built together in optional

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products 94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation

More information

MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY

MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS hyconelec.co.za MARECHAL TECHNOLOGY SAFE AND RELIABLE ELECTRICAL CONNECTIONS FOR YOUR MOTORS. MARECHAL ELECTRIC offers a range of

More information

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number Spec Sheet: IEC309 Switched Socket, Horizontal 16A Part Numbers Part Number EU67HSS316 EU67HSS416 EU67HSS516 Description IEC309 16A 3 Pin switched socket IEC309 16A 4 Pin switched socket IEC309 16A 5 Pin

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 0 Load and Motor Switchgear Motor Protection ircuitbreakers For use in Zone and Zone Zone and Zone For protection of Ex e and Ex d motors Protects cables and plant equipment Adjustable thermal overcurrent

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

Motor protection switches M16 20A Main switches S25 25A

Motor protection switches M16 20A Main switches S25 25A Motor protection switches M16 20A Main switches S25 25A DISA Elektro AG Kägiswilerstrasse 33 CH-6060 Sarnen Tel. 041 666 70 50 Fax 041 666 70 49 info@disa.ch www.disa.ch DISA your partner for individual

More information

TeSys enclosed starters 2 VARIO enclosed switch disconnectors, pre-assembled

TeSys enclosed starters 2 VARIO enclosed switch disconnectors, pre-assembled References VRIO enclosed switch disconnects, pre-assembled 0 0 0 VCF 0GE VCF GE VCF GEN Enclosed switch disconnects f high perfmance applications b -pole rotary switch disconnects, to 0, confming to IEC

More information

ATX DPD Series Distribution Panelboards Flameproof

ATX DPD Series Distribution Panelboards Flameproof ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation

More information

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes Protection and Connection Enclosed DC rated switchdisconnectors OTDCP from 16 to 32 Amperes Enclosed OTDC switches from 16 to 32 Amperes meet the demanding requirements of photovoltaic applications. Enclosed

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,

More information

Switch Disconnectors

Switch Disconnectors Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring: SERIES D DISCONNECT SWITCHES 1 Amp 0 Amp 00 & 0 Volt Load Make/Load Break Positive Opening Compact Size Modular Construction Horse Power Rated Custom Versions Featuring: Auto Alignment Shaft Wide Handle

More information

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations TP&N DISTRIBUTION BOARD TYPE B Distribution boards for modern commercial & industrial installations TP&N DISTRIBUTION BOARD - TYPE B Designed & Engineered in the UK Compliant to BS EN 61439-3:2012 Supplied

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE. Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K

More information

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,

More information

Safety Switches Series 8537

Safety Switches Series 8537 Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

TO ALL OUR CUSTOMERS. Poles

TO ALL OUR CUSTOMERS. Poles Page 1 TO ALL OUR CUSTOMERS 1. NEWS: NEW 20-32-40A THERMOPLASTIC ENCLOSURES FOR THE ISOLATORS SERIES The thermoplastic ISOLATORS series offer has been expanded, introducing a range of products for 20,

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

Motorised and automatic transfer enclosed switchess

Motorised and automatic transfer enclosed switchess s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >

More information

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects Low Voltage Switches Enclosed switches - eot Manual motor controllers and disconnects The next generation of enclosed switches General information The eot series of enclosed manual motor controllers are

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures coff_163_a_1_cat coff_156_b_1_cat Function equipped with SOCOMEC switches provide emergency breaking, breaking for mechanical maintenance and safety isolation in the vicinity of any low voltage final circuit.

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description. General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Euroload Changeover Switch

Euroload Changeover Switch Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.

More information

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity

More information

Manual Motor Starter MS 116. Technical Catalogue

Manual Motor Starter MS 116. Technical Catalogue Manual Motor Starter MS 116 Technical Catalogue The task: Economic fuseless motor protection Know-how in safe-keeping ABB is a renowned manufacturer of electrical motors. But apart from the hardware in

More information

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

LOAD BREAK SWITCHES. Ensto Compact

LOAD BREAK SWITCHES. Ensto Compact LOAD BREAK SWITCHES Ensto Compact Ensto Enclosures and Components Ensto also offers enclosed switches; being assemblies of Ensto Cubo enclosures and load break switches. Ensto is an international industrial

More information

25A 25A 32A 40A 40A 63A 63A 80A

25A 25A 32A 40A 40A 63A 63A 80A ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A

More information

KATKO Safety Switches:

KATKO Safety Switches: KATKO Safety Switches: Reliability, Economy, Safety KATKO/2007.01/AL 1 KUM 16-25A Dimensions: Overall: 130,4 x 96,4 x 42,0 Mounting holes: 118,0 x 84,0 -Polycarbonate or ABS IP65 enclosure -Excellent UV

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

ENYSTAR Load Centers up to 250 A

ENYSTAR Load Centers up to 250 A PASSION FOR POWER. up to 250 A according to IEC 61439-3 for commercial and industrial buildings Download at www.hensel-electric.en made in GERMANY since 1931 up to 250 A according to IEC 61439-3 for commercial

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES DESIGN FEATURES Double break contacts Polycarbonate shroud for wired terminal protection included Excellent switching & high short circuit capacity Compact and reliable Easy installation Front, rear and

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Softstarters. Catalogue. Type PSR. Catalogue 1SFC132003C0201 (1SFC132152F001)

Softstarters. Catalogue. Type PSR. Catalogue 1SFC132003C0201 (1SFC132152F001) Catalogue Softstarters Type PSR Catalogue w e N (1SFC132152F001) ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 *) ABB Automation

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A Integrated products & solutions The solution for > Iron and steel industry > Cement plants > Paper mills > Sawmills > Hydraulic power packs > Automotive > Mining coff_436_a coff_434_a Strong points Function

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250