Low Voltage Products. Breakers and Switches for the HVAC segment

Size: px
Start display at page:

Download "Low Voltage Products. Breakers and Switches for the HVAC segment"

Transcription

1 ow Voltage Products Breakers and witches for the VAC segment

2 ABB s extensive range of products for the VAC segment ABB s very extensive range of appliances and systems for low voltage power distribution includes a large selection of products for process control, protection and automation. In many countries, for example in the United tates, air conditioning accounts for over 40 percent of power consumption and, in general, motors use the most electrical power in starting, running and stopping fans, compressors and pumps. ABB s products for air conditioning applications include main switches, drives, components for motor starters and control panels and disconnect switches for isolation. Depending upon the application for which the equipment is to be used, ABB products are compliant with major international standards, in particular those in force in Europe (IEC) and orth America (U). ABB products are also used in industrial air filtration solutions world wide. Main switch applications witch-disconnectors and breakers are typically used in isolating individual sections of the plant or as the main switch for the whole VAC system, both AC and DC. ABB s breakers and switches are compact in size, have high ratings, unique safety features and global availability and acceptability. ABB switch-disconnectors range from 16 to 3150 amperes and the breakers from 20 to 2500 amperes in AC-23 switching categories. Motor starter applications Our switch-disconnectors and breakers are used in motor starter applications for switching and isolating. Together with contactors, thermal overload relays and fuselinks they also provide protection against overloads and short circuits. The circuit breakers are designed for starting, switching and protecting three-phase asynchronous motors. ABB proposes two different solutions for this type of application: a traditional system, with a circuit breaker for protection against short circuit, a thermal relay for protection against overload, missing or unbalanced phase and a contactor for motor switching a system of integrated protection with the PR222MP trip unit, which ensures both protection against short circuit and overload, as well as against missing or unbalanced phase and against rotor block Isolation applications ocal safety switches can be enclosed in plastic or metal enclosures for outdoor use up to protection class IP65. These products are typically used during maintenance to isolate individual sections or the whole system and mechanically secure the switch in open position by using padlocks. The ABB portfolio also includes cam switches The rotary cam switch range for control, instrumentation and motor starting applications provide you with a variety of functionalities for the most common mounting types with minimum footprint area. The range covers a variety of applications, from O-OFF, change-over, and multi-step to volt-ammeter, bypass, and UP. As the leading manufacturer of switch products, our vision, in cooperation with our customers and partners, is to further develop cost saving and environmentally safe solutions for the equipment used in the VAC segment in order to meet new needs and technical requirements. 2 ow Voltage Products Breakers and witches for the VAC segment

3 Enclosed switch-disconnectors provide the right solution in the power range kw/690 V, AC-23A The enclosed switches are suitable for power distribution in factories and buildings, as local motor isolators or main switches. Each incoming supply shall be provided with a hand operated main switch-disconnector according to the machine directive E and isolate the electrical equipment reliably from the supply. To meet these requirements the enclosures have handles that can be locked with padlocks in the OFF-position. The wide range of switch-disconnectors are available in plastic, steel sheet, stainless steel sheet and aluminum alloy enclosures from 16 to 1600 amperes. The most compact disconnect switch solution from 16 to 3150 amperes The switch-disconnector is largely used as the main switch in low voltage switchgears for distribution of power, starting and stopping motors and isolating loads during maintenance. The range from 16 to 160 amperes is either base plate or door mounted by snap-on or screw fitting. Front operated 3-, 4-, 6-, 8-pole and change-over types are available as standard. From up to 3150 amperes the switch-disconnectors are designed as pole modules and they are available as 1- to 4-pole versions, front or side operated and change-over switches. For fusible short circuit protection switch fuses are available for DI, B, FC, U and CA types of fuse links from 16 to 1250 amperes. Circuit breakers designed for protecting motors from 0.37 kw up to 355 kw in very compact sizes Two different protection solutions: traditional or integrated Advanced electronic protection units are available Exellent coordination with A and AF series ABB contactors and with ABB thermal release Wide choice of terminals and accessories Breakers and witches for the VAC segment ow Voltage Products 3

4 afety switches from 16 to 90 A Ratings according to IEC A OTP16T_ OTP25T_ 00692A OTP75T_ OTP36T_ OTP63T_ OTP90T_ Plastic enclosed front operated safety switches, IP65 The safety switch comes complete with a black selector type handle (I-O, O-OFF), PE and terminals and one O auxiliary contact. Knock-out openings with metric thread, also for control cables. Compression glands must be ordered separately. Max motor output Cable outlets/ Dimensions AC-23A side 230 V 400 V 690 V W D 3 pole 4 pole (mm) (mm) (mm) 5.5/23 7.5/16 7.5/10 2xM25+M OTP16T3M OTP16T4M 7.5/30 15/30 15/20 2xM32+M OTP25T3M OTP25T4M 11/38 22/38 15/20 2xM32+M OTP36T3M OTP36T4M 18.5/63 30/63 30/35 2xM32+M OTP63T3M 22/80 37/80 37/40 2xM50+M OTP75T3M OTP75T4M 22/90 45/90 45/50 2xM50+M OTP90T3M OTP90T4M 2CMC341011F0054 Plastic enclosed side operated safety switches, IP65 The safety switch comes complete with PE and terminals and one O auxiliary contact, cable entries with metric threaded knock-outs, IP 54 membrane glands/sealing plugs. For IP65 protection, compression glands must be used. BW316TP BW416TP 2CMC341011F0056 BW325TP BW425TP Max motor output Cable outlets/ Dimensions AC-23A side 230 V 400 V 690 V W D 3 pole 4 pole (mm) (mm) (mm) 7.5/16 7.5/10 2xM25/2xM BW316TP BW416TP 11/25 11/16 2xM32/2xM32+1xM BW325TP BW425TP teel sheet enclosed front operated safety switches, IP65 The safety switch comes complete with a black selector type (OT16 63) or pistol type (OT75 90) handle (I-O/O-OFF), one O auxiliary contact and PE terminal. Cable entries from bottom (OT ) or from top and bottom (OT ). Compression glands and flanges must be ordered separately A OT T_ Max motor output AC-23A 230 V 5.5/23 7.5/30 11/ /63 22/80 22/ V 7.5/16 15/30 22/38 30/63 37/80 45/ V 7.5/10 15/20 15/20 30/35 37/40 45/50 Cable outlets Dimensions 1xB flange 1xB flange 1xB flange 1xB flange 2xB flange 2xB flange W (mm) (mm) D (mm) pole OT16T3B OT25T3B OT36T3B OT63T3B OT75T3B OT90T3B 4 pole OT16T3B OT25T3B OT36T3B OT63T3B OT75T3B OT90T3B 01251A OT T_ For more information regarding aluminum and stainless steel enclosures, EMC protected types and sizes up to 1 kw/1250 A and accessories see the technical catalogue OT2GB_ 4 ow Voltage Products Breakers and witches for the VAC segment

5 cuus approved safety switches from 16 to 80 A Ratings according to cuus 508 uitable as motor disconnect Plastic enclosed front operated disconnect switches The disconnect switch include a black rotary operated selector (EMA3R/12) or pistol type (EMA4/4X) handle (I-O,O-OFF) and one O auxiliary contact. EMA 3R/12 6/ /28 15/42 20/54 Max horsepower/amp rating Three phase ingle phase 480 V 10/14 20/27 30/40 40/ V 10/11 25/27 30/32 40/ V 1/6 2/13.2 5/ /40 10/57.5 U G. P. amp rating W (mm/in) /3.94 / / /8.27 Dimensions (mm/in) 140/ / / /11.81 D (mm/in) 81/ / / / pole 4 pole EOT16U3P3-1 EOT16U4P3-1 EOT32U3P3-1 EOT32U4P3-1 EOT45U3P3-1 EOT45U4P3-1 EOT63U3P3-1 EOT63U4P3-1 EMA 4/4X 6/ /28 15/42 20/54 Max horsepower/amp rating Three phase ingle phase 480 V 10/14 20/27 30/40 40/ V 10/11 25/27 30/32 40/ V 1/6 2/13.2 5/ /40 10/57.5 U G. P. amp rating W (mm/in) /3.94 / / /8.27 Dimensions (mm/in) 140/ / / /11.81 D (mm/in) 81/ / / / pole 4 pole EOT16U3P4-1 EOT16U4P4-1 EOT32U3P4-1 EOT32U4P4-1 EOT45U3P4-1 EOT45U4P4-1 EOT63U3P4-1 EOT63U4P4-1 Breakers and witches for the VAC segment ow Voltage Products 5

6 witch-disconnectors from 16 to 1600 A Ratings according to IEC OT16-40F3 Front operated switch-disconnectors s OT for base and DI rail mounting, OT include protected terminal clamps. hafts and handles have to be ordered separately up to OT125. s OT include a black O-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the O-position B 02101A OT - 125F3 OT160E3 OT - 250E03P 220-3/16 4/20 5.5/23 11/45 22/75 22/80 22/90 45/135 60/ 75/250 / /400 / / / /0 310/1 Max motor output AC-23A V 7.5/16 9/20 5.5/23 22/45 37/75 37/80 45/90 75/ / 140/ / / / / / /0 560/0 440 V 7.5/16 9/20 5.5/23 22/45 37/65 37/65 45/78 75/ / 145/ / / / / / /0 630/0 500 V 7.5/16 9/20 5.5/23 22/45 37/58 37/60 45/70 75/ / 170/ / / / / / /0 710/0 690 V 7.5/10 9/11 11/12 15/ /20 37/40 45/50 75/80 / 259/ / / / / / / /0 Rated thermal current (A) pole 4 pole OT16F3 OT16F42 OT25F3 OT25F42 OT40F3 OT40F42 OT63F3 OT63F42 OT80F3 OT80F42 OTF3 OTF42 OT125F3 OT125F42 OT160E3 OT160E4 OTE03P OTE04P OT250E03P OT250E04P OT315E03P OT315E04P OT400E03P OT400E04P OT630E03P OT630E04P OT800E03P OT800E04P OT0E03P OT0E04P OT1250E03P OT1250E04P OT1600E03P OT1600E04P 02105A OT E03P More information for door mounted versions, accessories and sizes up to 3150 A in the technical catalogue OT_OET1GB_ KE00046 OT1600E03P 6 ow Voltage Products Breakers and witches for the VAC segment

7 on-fusible disconnect switches from 16 to 1 A Ratings according to cuus 508 and cuus OT16-40F3 Front operated, non-fusible disconnect switches s OT for base and DI rail mounting, OT include protected terminal clamps. hafts and handles have to be ordered separately up to OT. s OT include a black O-OFF plastic handle and shaft as standard. The handle is EMA 1, 3R/12 protected, padlockable in the OFF-position and with door interlock in the O-position. The shaft is adjustable for a range of installation depths A KE A OT30, 60, F3 OTU03P OT600U03P Approved according to cuus 508 5/ /22 10/28 15/42 20/54 Max horsepower/amp rating 480 V 10/14 15/21 20/27 30/40 40/ V 15/17 20/22 25/27 30/32 40/41 Approved according to cuus 98 10/28 20/54 30/80 40/104 75/ /312 / /602 Three phase 120 V 1/16 1.5/20 Max horsepower/amp rating Three phase 480 V 20/27 40/52 50/65 75/96 150/ / / / V 30/32 40/41 50/52 /99 / / / /472 ingle phase 2/13.2 3/18.7 5/ /40 10/57.5 ingle phase 120 V 3/34 5/56 7.5/80 5/28 7.5/40 15/68 20/88 General purpose amp rating A General purpose amp rating A pole OT16F3 OT25F3 OT40F3 OT63F3 OT80F3 3 pole OT30F3 OT60F3 OTF3 OT160E3 OTU03P OT400U03P OT600U03P OT800U03P OT1U03P 4 pole OT16F42 OT25F42 OT40F42 OT63F42 OT80F42 4 pole OT30F42 OT60F42 OTF42 OT160E4 OTU04P OT400U04P OT600U04P OT800U04P OT1U04P More information for door mounted versions, accessories and sizes up to 3150 A in the technical catalogue OT_OET1GB_ OT800-1U03P Breakers and witches for the VAC segment ow Voltage Products 7

8 witch fuses from 16 to 1250 A Ratings according to IEC A 01382A Front operated switch fuses, DI types Including terminal bolt kit (O ), a black O-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the O-position. The shaft is adjustable for a range of installation depths A 01129A O40FD10 O32-63D V 11/40 7.5/ /63 37/125 45/160 60/ 75/ /400 / / /0 315/0 Max motor output AC-23A 400 V 500 V 18.5/40 22/40 15/ /32 30/63 37/63 55/125 75/125 75/160 90/ / 132/ 140/ / / / / / / / /0 710/0* 560/0 710/0* 690 V 30/40 22/32 45/63* 110/125* 132/160* / 250/ / / /800 0/0* 0/0* Rated thermal current (A) Fuse size , , , , , 1 0, 1, a 3 pole 4 pole O40FD10 O40FD201 O32D12 O32D221 O63D12 O63D221 O125D03 O125D042 O160D03 O160D042 OD03P OD042P O250D03P O250D042P O400D03P O400D042P O630D03P O630D042P O800D03P O800D042P O1250D03P O1250D042P O1250DA03P O1250DA042P * Utilization category B O D A OD03 For more information and accessories see the technical catalogue O1GB_ KE00036 O630D03 8 ow Voltage Products Breakers and witches for the VAC segment

9 Fusible disconnect switches from 30 to 1 A Ratings according to cuus A 00799A 01125A O30FA_12P O60J12P OJ03P Front operated fusible disconnect switches Including terminal bolt set from A and up, a black O-OFF plastic handle and shaft as standard. The handle is EMA 1, 3R&12 protected, padlockable in the OFF-position and with door interlock in the O-position. The shaft is adjustable for a range of installation depths. Approved according to cuus 98 Max horsepower/amp rating General Three phase ingle phase 7.5/22 7.5/22 15/42 30/80 60/ /312 / / V 15/21 15/21 30/40 60/77 125/ / / / V 20/22 20/22 50/52 75/77 150/ / / / V 3/17 3/17 purpose amp rating A Fuse type, size CC, 30 A J, 30 A J, 60 A J, A J, A J, 400 A J, 600 A, 800 A, 1 A 3 pole O30FACC12P O30FAJ12P O60J12P OJ03P OJ03P O400J03P O600J03P O80003P O103P 4 pole O30FACC22FP O30FAJ22FP O60J22FP OJ04FP A 02160A OJ03P For more information and accessories see the technical catalogue O1GB_ O400J03P O103P Breakers and witches for the VAC segment ow Voltage Products 9

10 Motor protection circuit-breakers Ordering codes IEC ratings T2 160 Fixed (F) 3 Poles - Front terminals (F) 1DC210303F0004 In I 3 Magnetic only trip unit - MF and MA * ) Icu (415 V) ka ka 70 ka ka In Electronic trip unit Icu (415 V) PR221D-I PR221D-I PR221D-I PR221D-I PR221D-I PR221MP PR221MP PR221MP ote: The trip coil of the T2 circuit-breaker with PR221D electronic trip unit is housed in the right slot. For T2 with PR 221D the following groups of auxiliary contacts are available: - 1DA053704R1 Aux-C 151-1Q-1Y - 1DA055504R1 Aux-C 2Q-1Y 36 ka ka ka ka T3 250 Fixed (F) 3 Poles - Front terminals (F) In I 3 Magnetic only trip unit - MA Icu (415 V) ka ka ote: T2, T4, T5 and T6 in three poles version equipped with PR221D-I electronic trip unit can be used for motor protection. * ) MF = Magnetic only trip unit with fixed magnetic thresholds MA = Magnetic only trip unit with adjustable magnetic thresholds 10 ow Voltage Products Breakers and witches for the VAC segment

11 Motor protection circuit-breakers Ordering codes IEC ratings T4 250 Fixed (F) 3 Poles - Front terminals (F) 1DC210305F0004 In I 3 Magnetic only trip unit - MA Icu (415 V) ka ka 120 ka In Electronic trip unit for motor protection Icu (415 V) PR222MP PR222MP 160 PR222MP 36 ka ka 120 ka In Electronic trip unit Icu (415 V) PR221D-I PR221D-I 160 PR221D-I ka ka 70 ka ka V ka T4 320 Fixed (F) 3 Poles - Front terminals (F) In I 3 V Electronic trip unit Icu (415 V) 36 ka 50 ka 70 ka 120 ka ka PR221D-I ote: T2, T4, T5 and T6 in the three-pole version equipped with PR221D-I electronic trip units and T7 in the three-pole version equipped with PR231/P-I electronic trip units, can be used for motor protection. For more information following documents are available at Technical catalogue T max T Generation QT7 Technical application papers Breakers and witches for the VAC segment ow Voltage Products 11

12 Motor control protection circuit breakers Ordering codes U/CA ratings T2 Fixed (F) 3 Poles U isted Iu (40 C) = A - Front terminals (F) 1DC210A09F0001 I 3 Magnetic only trip unit - MA Icu (480 V) ka ka Electronic trip unit for motor protection Icu (480 V) PR221 D-I 25 PR221 D-I 60 PR221 D-I 35 ka ka T3 225 Fixed (F) 3 Poles U isted Iu (40 C) = 225 A - Front terminals (F) 1DC210304F0004 U 1DC210304F0004 U I 3 Magnetic only trip unit - MA Icu (480 V) Ts3 150 Fixed (F) 3 Poles U isted Iu (40 C) = 150 A - Front terminals (F) I 3 Magnetic only trip unit - MA Icu (480 V) ka ka ka ow Voltage Products Breakers and witches for the VAC segment

13 Motor control protection circuit breakers Ordering codes U/CA ratings Ts3 225 Fixed (F) 3 Poles U isted Iu (40 C) = 225 A - Front terminals (F) I 3 Magnetic only trip unit - MA Icu (480 V) ka T4 250 Fixed (F) 3 Poles U isted Iu (40 C) = 250 A - Front terminals (F) 1DC210305F0004 U Electronic trip unit for motor protection Icu (480 V) PR221 D-I PR221 D-I 150 PR221 D-I ka ka 65 ka ka T5 400 Fixed (F) 3 Poles U isted Iu (40 C) = 400 A - Front terminals (F) Electronic trip unit for motor protection Icu (480 V) PR221 D-I 300 PR221 D-I ka ka 65 ka ka T5 600 Fixed (F) 3 Poles U isted Iu (40 C) = 600 A - Front terminals (F) 1DC210306F0004 U Electronic trip unit for motor protection Icu (480 V) PR221 D-I 600 T6 800 Fixed (F) 3 Poles U isted Iu (40 C) = 800 A - Front terminals (F) Electronic trip unit for motor protection Icu (480 V) PR221 D-I 600 PR221 D-I ka ka ka 65 ka ka 65 ka ka ka For more information following documents are available at Technical catalogue T max T Generation QT7 Technical application papers Breakers and witches for the VAC segment ow Voltage Products 13

14 Drives applications ABB switch-disconnectors and breakers are commonly used as main switch in drives applications. Together with the protection functions embedded in ABB standard drives for VAC applications they provide protection against several fault situations such as motor short circuit, overvoltage and overcurrent. In VAC applications, most of which are pumps and fans, AC drives can cut energy bills by as much as 80 percent. Power savings of up to 50 percent can be reached by reducing the motor speed by 20 percent. ABB has delivered millions of AC drives worldwide, cutting electricity consumption by about 140 TWh per year. This corresponds to an average reduction in CO 2 emissions of over 70 million tonnes every year. One of the biggest benefits of using ABB standard drives for VAC applications is the superior energy saving opportunity it creates compared to fixed speed motors or conventional flow control methods. Rather than have an electric motor running continously at full speed, an AC drive allows the user to variably control the motor speed, depending on the demand. 14 ow Voltage Products Breakers and witches for the VAC segment

15 Ordering information BW316 TP BW325 TP BW416 TP BW425 TP EOT16U3P3-1 EOT16U3P4-1 EOT16U4P3-1 EOT16U4P4-1 EOT32U3P3-1 EOT32U3P4-1 EOT32U4P3-1 EOT32U4P4-1 EOT45U3P3-1 EOT45U3P4-1 EOT45U4P3-1 EOT45U4P4-1 EOT63U3P3-1 EOT63U3P4-1 EOT63U4P3-1 EOT63U4P4-1 OJ03P OJ04FP O103P O1250D03P O1250D042P O1250DA03P O1250DA042P O125D03 O125D042 O160D03 O160D042 OD03P OD042P OJ03P O250D03P O250D042P O30FACC12P O30FACC22FP O30FAJ12P O30FAJ22FP O32D12 O32D221 O400D03P O400D042P O400J03P O40FD10 O40FD201 Order code 2CMA142417R0 2CMA142420R0 2CMA142418R0 2CMA142421R0 1CA022809R1560 1CA114773R1 1CA022863R7890 1CA114774R1 1CA022809R1640 1CA114782R1 1CA022863R8510 1CA114776R1 1CA103985R1 1CA114777R1 1CA114778R1 1CA114783R1 1CA114784R1 1CA114780R1 1CA114781R1 1CA114786R1 1CA022456R8810 1CA022508R2700 1CA105468R1 1CA105475R1 1CA105248R1 1CA105238R1 1CA105243R1 1CA022469R8780 1CA022507R3030 1CA022456R8310 1CA022507R2650 1CA022709R9500 1CA022709R9680 1CA022709R9760 1CA022719R0090 1CA022719R2380 1CA108817R1 1CA108821R1 1CA108828R1 1CA108831R1 1CA022456R9710 1CA022456R9890 1CA022719R0250 1CA022719R2460 1CA022719R1140 1CA108914R1 1CA108938R1 O600J03P O60J12P O60J22FP O630D03P O630D042P O63D12 O63D221 O800D03P O800D042P O80003P OT0E03P OT0E04P OTF3 OTF42 OT1U03P OT1U04P OT1250E03P OT1250E04P OT125F3 OT125F42 OT1600E03P OT1600E04P OT160E3 OT160E4 OT16F3 OT16F42 OTE03P OTE04P OTU03P OTU04P OT250E03P OT250E04P OT25F3 OT25F42 OT30F3 OT30F42 OT315E03P OT315E04P OT400E03P OT400E04P OT400U03P OT400U04P OT40F3 OT40F42 Order code 1CA022825R8870 1CA022434R8290 1CA022472R0460 1CA022825R2830 1CA022825R4290 1CA022434R7810 1CA022457R0040 1CA022825R4880 1CA022825R5180 1CA022825R9920 1CA022860R5930 1CA022860R6150 1CA105004R1 1CA105018R1 1CA022860R6910 1CA022860R7120 1CA022860R6230 1CA022860R6310 1CA105033R1 1CA105056R1 1CA022860R6580 1CA022860R6740 1CA022257R5950 1CA022259R8060 1CA104811R1 1CA104829R1 1CA022712R0800 1CA022713R4930 1CA022709R9920 1CA022710R0610 1CA022710R0 1CA022710R0520 1CA104857R1 1CA104886R1 1CA105068R1 1CA108347R1 1CA022718R8510 1CA022719R1730 1CA022718R8780 1CA022719R1810 1CA022718R9670 1CA022719R1900 1CA104902R1 1CA104932R1 OT600U03P OT600U04P OT60F3 OT60F42 OT630E03P OT630E04P OT63F3 OT63F42 OT800E03P OT800E04P OT800U03P OT800U04P OT80F3 OT80F42 OT16T3B OT25T3B OT36T3B OT63T3B OT75T3B OT90T3B OTP16T3M OTP16T4M OTP25T3M OTP25T4M OTP36T3M OTP36T4M OTP63T3M OTP75T3M OTP75T4M OTP90T3M OTP90T4M Order code 1CA022718R9830 1CA022719R2 1CA105076R1 1CA108348R1 1CA022718R8940 1CA022719R2030 1CA105332R1 1CA105365R1 1CA022718R9410 1CA022719R2110 1CA105665R1 1CA105667R1 1CA105798R1 1CA105413R1 1CA022571R9150 1CA022571R9230 1CA022571R9310 1CA022571R9400 1CA022546R0820 1CA022546R1120 1CA022400R9910 1CA022401R0500 1CA022401R0090 1CA022401R0680 1CA022401R0170 1CA022401R0760 1CA022608R2910 1CA022812R2890 1CA022812R3010 1CA022812R2970 1CA022812R3190 For breaker ordering, see pages 10 to 13 Breakers and witches for the VAC segment ow Voltage Products 15

16 Contact us ABB Oy ow Voltage Products P.O. Box 622 FI Vaasa, Finland Phone: Fax: ABB ACE.p.A. ow Voltage Breakers Via Baioni, 35 I Bergamo, Italy Phone: Fax: The data and illustrations are not binding. We reserve the right to make changes in the course of technical development of the product. Copyright 9 ABB. All rights reserved. VAC10GB CC014B0201 Printed in Finland, 10-9/0, Waasa Graphics

Disconnect switches Non-fusible Fusible Enclosed

Disconnect switches Non-fusible Fusible Enclosed Disconnect switches Non-fusible Fusible Enclosed Low voltage disconnect switches from ABB ABB is committed to offering high quality and innovative low voltage products. ABB s disconnect switch lines are

More information

Low Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201

Low Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201 Low Voltage Products Enclosed switches Brochure OT_KSE 1 GB 05_02 O I N O SafeLine OF F 2 I Enclosed switches Contents: General... 4 Technical data... 5 Switches in plastic enclosure General... 6 Ordering

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Breakers and Switches. Switches Switch-disconnectors OT and OTM Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,

More information

Switch-disconnectors OT , OETL 3150

Switch-disconnectors OT , OETL 3150 Switch-disconnectors OT 16...2500, OETL 3150 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 Front operated switch-disconnectors OT, OETL 24 Side operated

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Enclosed switches and safety switches Main Catalogue. 2CMC341002D0002 January 2009

Enclosed switches and safety switches Main Catalogue. 2CMC341002D0002 January 2009 Enclosed switches and safety switches Main Catalogue January 2009 Enclosed switches and safety switches Contents General description/technical data... 4 Ratings... 8 Switch-disconnectors / isolators Plastic

More information

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution

More information

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects Low Voltage Switches Enclosed switches - eot Manual motor controllers and disconnects The next generation of enclosed switches General information The eot series of enclosed manual motor controllers are

More information

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes Protection and Connection Enclosed DC rated switchdisconnectors OTDCP from 16 to 32 Amperes Enclosed OTDC switches from 16 to 32 Amperes meet the demanding requirements of photovoltaic applications. Enclosed

More information

Reliable in extreme conditions

Reliable in extreme conditions Protection and Connection OT Non-fusible Disconnect Switches 1600...2000 Amperes OT51GB 16-07 1SCC301023K0201 Reliable in extreme conditions Space saving Easy to install Suitable for heavy duty applications

More information

PowerLine OS Switch Fuses A, 690V

PowerLine OS Switch Fuses A, 690V Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected

More information

Breakers and Switches. Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP

Breakers and Switches. Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Breakers and Switches Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Switch-disconnectors OTDC16...250, OT315...630 and OTDCP16...32 Contents 4 Product overview 8 Technical data

More information

Breakers and Switches. Enclosed switches Safety switches A

Breakers and Switches. Enclosed switches Safety switches A Breakers and Switches Enclosed es Safety es 16...1250 A Safety es From 16...1250 Amperes Contents 04 Product overview, features 10 Technical data, cabling 14 Safety es, ordering information 14 Plastic

More information

Low Voltage Products. Switches Switch-disconnectors OT and OETL

Low Voltage Products. Switches Switch-disconnectors OT and OETL Low Voltage Products Switches Switch-disconnectors OT and OETL Switch-disconnector IEC lth /A le /AC22A, 415V le /AC23A, 415V... OT16F OT63F OT100F OT160E OT25F OT80F OT125F OT40F 25 32 40 63 80 115 125

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Softstarter Intelligent Controllers

Softstarter Intelligent Controllers Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Motor Starting Solutions Open Type Version, in Kit Form

Motor Starting Solutions Open Type Version, in Kit Form Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Manufacturer Item Number Item Description QTY Available ABB 1SAM250000R1007 MS , THERMAL AND ELECTROMAGNETIC TRIP 5 ABB

Manufacturer Item Number Item Description QTY Available ABB 1SAM250000R1007 MS , THERMAL AND ELECTROMAGNETIC TRIP 5 ABB ABB 1SAM250000R1007 MS116-2.5, THERMAL AND ELECTROMAGNETIC TRIP 5 ABB 1SAZ211201R1043 TA25-DU-11A-THERMAL-OVERLOAD 0 ABB 1SAZ211201R1047 TA25-DU-19A-THERMAL-OVERLOAD 3 ABB 1SAZ211201R1051 TA25-DU-25A-THERMAL-OVERLOAD

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Item Code Description Quantity 1SAZ211201R1028 TA25-DU 2,4A THERMAL O/L ( ) 1 1SAZ211201R1043 TA25-DU-11A-THERMAL-OVERLOAD 0

Item Code Description Quantity 1SAZ211201R1028 TA25-DU 2,4A THERMAL O/L ( ) 1 1SAZ211201R1043 TA25-DU-11A-THERMAL-OVERLOAD 0 Controlgear Products +27 () 11 97 116 sales@controlgear.co.za ABB stock items on hand as at Sun, 4/2/218, 9:2 GMT+2 1SAM25R17 MS116-2.5, THERMAL AND ELECTROMAGNETIC TRIP 1 1SAZ21121R128 TA25-DU 2,4A THERMAL

More information

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201 Low Voltage Products SwitchLine OT change-over switches 160, 200, 0, 315, 400, 630 and 800 mps Catalogue OT7G 05_09 1SCC301012C0201 Ith / Ie /C22, 415V Ie /C23, 415V OT160E OT160E_W OT200E OT200E_W OT0E

More information

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A Quality For You. How simple and functional can a range of moulded-case circuit-breakers be? It was answering this question, which

More information

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

AC Switches: ML & MN Series DC Switches: MDC1A Series

AC Switches: ML & MN Series DC Switches: MDC1A Series AC Switches: ML & MN Series DC Switches: MDC1A Series Australian & New Zealand Distributor Leveltec Engineering Pty Ltd Gloucester P:+612 6558 9264 F:+612 6558 1002 Sydney P:+612 9299 5630 F:+612 6558

More information

for Non-Fusible Disconnect Switches

for Non-Fusible Disconnect Switches Overview for on- Disconnect Switches CDF16 CDF100A3 CDF16A3, CDF25A3, CDF32A3 CDF30A3, CDF60A3, CDF100A3 CDF160 3 pole CDF16A3 CDF25A3 CDF32A3 CDF45A3 CDF63A3 CDF30A3 CDF60A3 CDF100A3 General purpose amp

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers Move to modern enclosed disconnect switch technology Enclosed disconnect switches eot Manual motor controllers The next generation of enclosed disconnect switches... Cutting edge design and technology

More information

UL 98 Fusible Disconnect Switches

UL 98 Fusible Disconnect Switches UL 98 Fusible isconnect witches ICONNECT WITCHE Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark conforming to IEC 60947-3. They are service entrance devices capable of fully

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

IEC Contactors & Starters XT IEC Power Control

IEC Contactors & Starters XT IEC Power Control July 008-9 Contents Description Page umber Selection................ - Product Selection.......... - Accessories............... -8 Technical Data and Specifications............ -0 Dimensions...............

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

Manual motor starters Overview and benefits

Manual motor starters Overview and benefits Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Preliminary - 1SDC210003B0201. New Tmax T4-T5. T Generation.

Preliminary - 1SDC210003B0201. New Tmax T4-T5. T Generation. Preliminary - 1SDC210003B0201 New Tmax T4-T5. T Generation. BE FREE! T ry to think of an installation which needs 600 A. Have you done that? Now think of sizing it, selecting the products, the accessories

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

US Catalog. Motor protection and control AF Range contactors & overload relays

US Catalog. Motor protection and control AF Range contactors & overload relays US Catalog Motor protection and control AF Range contactors & overload relays Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors (500

More information

L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR

L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR The safest way to switch power on and off in your industrial control panels. Your problem: You

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Brocure panorama. Switches for photovoltaic applications Disconnect switches OTDC and OTDCP

Brocure panorama. Switches for photovoltaic applications Disconnect switches OTDC and OTDCP Brocure panorama Switches for photovoltaic applications Disconnect switches OTDC and OTDCP DC switch-disconnectors, front operated 16...800 A, IEC IEC 60947 OTDC16F2 OTDC16F3 OTDC16F4 OTDC100E02 OTDC100E11

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Enclosed Switches and Safety Switches

Enclosed Switches and Safety Switches Enclosed Switches and Safety Switches Enclosed Switches and Safety Switches Contents General information... 2 Description... 5 Ratings... 8 Plastic enclosed switches and safety switches...11 Metal enclosed

More information

Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP

Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Breakers and Switches Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Switch-disconnectors OTDC16...250, OT315...630 and OTDCP16...32 Contents 4 Product overview 8 Technical data

More information

Breakers and Switches. Switches Change-over and transfer switches

Breakers and Switches. Switches Change-over and transfer switches Breakers and Switches Switches Change-over and transfer switches Change-over and transfer switches 16...2500 A Contents: 4 Product overview, features 8 Technical data 8 Manual, motorized and automatic

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors... Enclosed Starters 20 Contents Motor nominal powers and current... 20/2 Panorama... 20/3 Starting of three-phase asynchronous motors... 20/4 Ordering Details Enclosed D.O.L starters - Protection by thermal

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA ENCLOSED SWITCHES SAFETY SWITCHES / ISOLATORS 16-800A TECHNICAL DATA Safety switches / isolators 10A 16A 25A 40A 63A 80A 125A 160A 200A 250A 315A 400A 630A 800A Rated Insulation voltage Ui (V) 690 690

More information

for Non-Fusible Disconnect Switches

for Non-Fusible Disconnect Switches Overview for Non- Disconnect Switches CDNF16 CDNF100A3 CDNF16A3, CDNF25A3, CDNF32A3 CDNF30A3, CDNF60A3, CDNF100A3 CDNF160 number 3 pole CDNF16A3 CDNF25A3 CDNF32A3 CDNF45A3 CDNF63A3 CDNF30A3 CDNF60A3 CDNF100A3

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

for Non-Fusible Disconnect Switches

for Non-Fusible Disconnect Switches Overview CDNF16 CDNF100A3 CDNF16A3,, CDNF32A3 CDNF30A3,, CDNF100A3 CDNF160 number 3 pole CDNF16A3 CDNF32A3 CDNF45A3 CDNF63A3 CDNF30A3 CDNF100A3 General purpose amp rating A 16 25 40 60 80 30 60 100 2 pole

More information

ABB s new control and protection devices

ABB s new control and protection devices ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

The complete offer Enclosed switch-disconnectors / Isolators

The complete offer Enclosed switch-disconnectors / Isolators June 2009 The complete offer Enclosed switch-disconnectors / Isolators May 29, 2009 Slide 1 Contents Why use enclosed switch-disconnectors Applications and application demands The ABB products and features

More information

Motor protective circuit breakers

Motor protective circuit breakers Motor protective circuit breakers Motor protective circuit breakers MSP Description The MSP0, MSP1 motor starter protectors are compact motor starter protectors for currents up to 52 A which operate according

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

1SDC210015B0203. Tmax. T Generation.

1SDC210015B0203. Tmax. T Generation. 1SDC210015B0203 Tmax. T Generation. T GENERATION. COMPLETE C omplete Freedom is a fully coordinated family of moulded-case circuit-breakers up to 1600 A. Complete Freedom is a family able to solve all

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes OTDC16...32U - Compact efficiency OTDC from 16 to 32 amperes offers various DC voltage ratings and a control

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

Technical Brochure. Switch Fuses DIN and NFC-Standard. Selection Table. Brochure OESA 2DIN GB Mallipohja. Low Voltage Products

Technical Brochure. Switch Fuses DIN and NFC-Standard. Selection Table. Brochure OESA 2DIN GB Mallipohja. Low Voltage Products Technical Brochure Switch Fuses DN and NFC-Standard Selection Table Brochure ESA 2DN GB 99-12 Mallipohja Powerline S switch fuses 20...160A, 690 V Unique patented design for the 21st century Total user

More information

Low Voltage Products Price list. ABB Authorised Dealer R Sanghavi Mercantile Pvt. Ltd.

Low Voltage Products Price list. ABB Authorised Dealer R Sanghavi Mercantile Pvt. Ltd. With effect from st March 205 Low Voltage Products Price list ABB low voltage products ABB is a global leader in power and automation technologies that enable utility and industry customers to improve

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic

More information