ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

Size: px
Start display at page:

Download "ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions"

Transcription

1 to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They are a combination of two loadbreak switches mounted back to back electrically and mechanically interlocked. They provide manual switching or remote controlled source inversion or changeover under load, of two low voltage power circuits. Conformity to standards IEC 0947 EN 0947 NBN EN 0947 BS EN 0947 GB 4048 IEC 0947 EN 0947 NBN EN 0947 BS EN 0947 VDE 0007 General characteristics Isolation with positive break indication. On load switching. Manual emergency operation. stable positions (I, 0, II) or overlapping contacts on request (I, I+II, II), for only. Padlocking in 0 or in all three positions (I, 0, II). AUTO / MANU selector. s atys_0_a cat atys_00_a cat m A. 0 without prior notice in view of continued improvement

2 Illustrations M from to 0 A 5 atys_5_a x_cat atysm_0_a x_cat from 5 to 00 A Overview (for further details, please see the installation instructions supplied with each device).. D0 or D0 remote interfaces ( M e only). or auxiliary contacts. Terminal shrouds 4. Voltage sensing and power supply tap 5. Bridging bars. Backup handle and support (included with device). Handle key interlocking accessories. Door protective surround 4. Additional auxiliary contacts 5. Standard device. Connecting cable for D0 or D0 remote interfaces ( ) 7. D0 or D0 interfaces ( ) 8. Plugin optional modules (not for s) 9. Voltage sensing and power supply kit ( ) 0. Terminal shrouds. Bridging bars. Mounting spacers. Terminal screens without prior notice in view of continued improvement A.

3 to 00 A Accessories Enclosed Characteristics M atysm_0_a cat atysm_0_a cat atysm_07_a cat atysm_08_a cat atys a cat Rating (A) No. of poles M s () Bridging bars Voltage sensing and power supply tap Terminal shrouds () Auxiliary contacts () DPS Double power supply pair pair st AC standard nd AC () Powersupply voltage 0 VAC. () pieces: top and bottom. () contact block for I, 0 and II positions. M atysm_007_a cat atysm_05_a cat atysm_0_a cat atysm_07_a cat atysm_08_a cat atys_55_c cat atysm_04_a atysm_05_a cat Rating (A) No. of poles Network (VAC) M s M e Bridging bars Voltage sensing and power supply tap Terminal shrouds () Auxiliary contacts () Remote interface () Sealable cover (4) 7 / / / / / 0 0 / / pair pair D D / / 0 0 / () To shroud front switch top and bottom references required. () contact block for I, 0 and II positions. () For M eonly. (4) For M sonly. A. without prior notice in view of continued improvement

4 atys_00_a cat acces_05_a cat acces_0_a cat acces_07_a cat Rating (A) 5 0 No. of poles s (4) (4) e Bridging bars Terminal shrouds ()() Terminal screens () P (4) P (4) P (4) P (4) P (4) P (4) (4) P See page A. Copper bars connection kits s e Rating (A) () To shroud front switch top and bottom references required. () To fully shroud front and rear / top and bottom 4 references required. () set: top and bottom. (4) Available enclosed (see page A.4 Enclosed s ). (5) Factory fitted. () The first contact is on the electronic part (the second and the third contacts are as standard). Plugin optional modules RS inputs / outputs Auxiliary contacts (5) () Control voltage transformer 400/0 VAC OTHER ACCESSORIES DC power supply VDC VDC Padlocking (5) Handle key interlocking accessories (5) Door protective surround Mounting spacers DPS Double power supply VDC without prior notice in view of continued improvement A.

5 to 00 A Accessories Enclosed Characteristics Commutateur VM I0II atys_097_b cat acces_05_a cat acces_0_a cat acces_0_a cat acces_07_a cat Rating (A) No. of poles e m Bridging bars Voltage sensing kit Terminal shrouds ()() Terminal screens () (4) (4) P (5) () (4) P (5) () (4) P (5) () (4) P (5) () (4) (4) (4) P P (5) () (5) () (4) P (5) () Rating (A) Plugin optional modules RS inputs / outputs Remote control interface D D RJ45 connecting cable See page A.8 Copper bars connection kits + OTHER ACCESSORIES Auxiliary contacts (7) (8) Control voltage DC transformer power 400/0 VAC supply Padlocking (7) (5) () VDC VDC VDC Handle key interlocking accessories (7) 9 00 Door protective surround Mounting spacers () To shroud front switch top and bottom references required. () To fully shroud front and rear / top and bottom 4 references required. () set: top and bottom. (4) Available enclosed (see page A.5 Enclosed e ). (5) Neutral on the right. () Neutral on the left. (7) Factory fitted. (8) The first contact is on the electronic part (the second and the third contacts are as standard). A. 4 without prior notice in view of continued improvement

6 M Accessories Bridging bars atysm_05_a cat To provide common point on either incoming or outgoing terminals. No. of poles Voltage sensing and power supply tap atysm_0_a cat Allows up to x <=.5 mm voltage sensing or power cables connection. To be mounted in any terminal cage when bridging bar not used. No. of parts 0 Pair () () parts per reference. atysm_07_a cat Terminal shrouds Protection against direct contact with the connection terminals or parts. Advantages Perforations enabling remote thermographic inspection without dismantling. No. of parts Position 0 Pair Top and bottom () () To shroud front changeover top and bottom references required. Auxiliary contacts atysm_08_a cat Up to auxiliary contacts accessory per product. Each accessory integrates NOC auxiliary contacts, one per position I, 0, II. Characteristics: VAC / 5 A maximum. For M s 0 standard st AC nd AC For M s and e Sealable cover atysm_04_a Controls settings cover to prevent M sparameters access due to a sealable facility without prior notice in view of continued improvement A. 5

7 to 00 A Accessories Enclosed Characteristics acces_05_a cat Accessories Bridging bars To provide common point on either incoming or outgoing terminals. No. of poles Section (mm) 5 0 P 0 x P 5 x P x P x P x P 0 x P 90 x acces c x_cat acces_04_a cat acces_8_b x_cat acces_0_b x_cat Copper bars connection kits Fig. Fig. Fig. C E C D B B A A A To allow: connection between the two power terminals from a same pole for 000 to 00 A ratings (Fig. and Fig ), top or bottom bridging connection (Fig. ). For 00 A rating, the connection piece (part A) are delivered bridged from factory. Bolt sets must be ordered separately. See page A.45, for connection kit assembly. Technical notice for these specific accessories is downloadable from Top or bottom flat connection Fig. Qty to order Part per pole () Connection piece part A Bolt set part B Connection piece part A Bolt set part B / standard Top or bottom edgewise connection Fig. Qty to order Part per pole () Connection piece part A T piece part C 9 00 () Right angle part D 9 00 () 00 Connection piece part A / standard 00 T piece part C 9 00 () 00 Right angle part D 9 00 () Top or bottom bridging connection Fig. Qty to order Part per pole () Connection piece part A Bolt set part B Bar part E () T piece part C 9 00 () Connection piece part A Bolt set part B / standard Bar part E () 00 T piece part C 9 00 () () Example for pole device equipped top only: order times the quantities. () Bolt set is provided with the accessories. A. without prior notice in view of continued improvement

8 Accessories Voltage sensing and power supply kit atys_0_a cat atys_0_a cat From 5 to 0 A For power supply and voltage measurement (4 wires, three phases). Routing of the conductors is controlled, which means that no specific protective device is necessary for these connections. The kit can be fitted on the top or the bottom of the switch. NB: the pole version does not integrate the power supply. For pole For 4 pole Neutral on the right Neutral on the left From 800 to 00 A Plugin optional modules atys_0_a cat No. : COM module control and state feedback of the changeover switch via a or wire RS485 link with JBUS/MODBUS protocol and transmission speed up to 8,400 baud. No. : module with inputs/ outputs For e: inputs: changeover control + backup network availability ; outputs: a load shedder relay + fault relay. For e and m: inputs/ outputs, programmable. Description of accessories COM RS485 (No. ) inputs/ outputs (No. ) without prior notice in view of continued improvement A. 7

9 to 00 A Accessories Enclosed Characteristics acces_0_a cat Accessories Terminal shrouds Protection against direct contact with the connection terminals or parts. Advantages Perforations enabling remote thermographic inspection without dismantling. No. of poles Position 5 0 top / bottom / front (I) / rear (II) ()() 5 0 top / bottom / front (I) / rear (II) ()() 400 top / bottom / front (I) / rear (II) 94 0 ()() 400 top / bottom / front (I) / rear (II) ()() 0 top / bottom / front (I) / rear (II) ()() 0 top / bottom / front (I) / rear (II) ()() () To shroud front switch top and bottom references required. () To fully shroud front and rear / top and bottom 4 references required. Terminal screens acces_07_a cat Top or bottom protection against direct contacts with the connection terminals or parts. No. of poles Position 5 0 top or bottom top or bottom top or bottom top or bottom top or bottom top or bottom top or bottom top or bottom top or bottom top or bottom top or bottom top or bottom acces_0_a cat Inter phase barriers Safety isolating separation between the terminals, essential for use at 90 VAC or in a dusty atmosphere. The terminal shrouds also provide phase separation for from 5 to 0 A. No. of poles / standard A. 8 without prior notice in view of continued improvement

10 Accessories Auxiliary contacts acces_05_a cat Prebreaking and signalling of positions I and II: extra NO / NC auxiliary contact in each position (factory fitted). Low level AC: please consult us. For s For e, e and m () () The first contact is on the electronic part (the second and the third contacts are as standard). Control voltage transformer Enables a 0 VAC device to be supplied with 400 VAC DC power supply Allows standard, to be DC power supplied. To be positioned as close as possible from DC power supply source. Not available for ratings from 000 to 00 A. Voltage VDC / 0 VAC VDC / 0 VAC VDC / 0 VAC Padlocking in the positions I0II Atys_5_a cat Allows locking of the operation in the positions I, 0 and II. Factory fitted without prior notice in view of continued improvement A. 9

11 to 00 A Accessories Enclosed Characteristics Accessories Handle key interlocking accessories Atys_0_a cat Locking the electrical control and the backup control in position 0 using a RONIS ELAP lock. Factory fitted. As standard, locking in position 0. Optional padlocking in positions: 0, I and II Mounting spacers atys_009_a cat Raises the device s terminals 0 mm away from the bottom of the enclosure or frame on which the device is mounted. This may also be used to replace the original mounting spacers. Description of accessories 5 0 set of spacers Door protective surround atys_595_a cat Door finishing surround for protecting application. For s For e, e and m A. 0 without prior notice in view of continued improvement

12 Accessories Remote interfaces for M e and e, m, C0 Dedicated to applications where the is back panel mounted. Interfaces are self powered from the. Maximum connection distance: m. Description D0 interface D0 interface atys_54_c cat D0 To display source availability and changeover state on the cabinet front panel, IP alone. D0 In addition to the D0 allows displays, operation and configuration on the cabinet front panel, IP alone. atys_55_c cat Door mounting holes Ø.5. Master connection via RJ45 cable, not isolated. atys_597_a cat RJ45 link for connection 9 x 9 Ø.5 atys a x_cat = = 40 0 Drilled holes without prior notice in view of continued improvement A.

13 to 00 A Accessories Enclosed Characteristics Accessories Connecting cable for remote interfaces D0 / D0 atys_09_a cat Connection between interface (type D0 or D0) and Meor e, m, C0. Characteristics: RJ45 8 wires not insulated straight connection, meters length. For M e and e, m, C0 Type RJ45 cable Length m Double power supply DPS Allows for M s and s to be supplied by two 0 VAC /0 Hz networks. For M s and s Description Double Power Supply (DPS) atys a cat Inputs The input is considered as active from 00 VAC. Max. voltage: 80 VAC. Internal protection: each input is fuse protected (x SA.5 A). Connection on terminals: max. mm. Modular device: 4 modules width. Input Input Output 0 VAC 0 VAC 0 VAC (Input ) 0 VAC 0 VAC 0 VAC (Input ) 0 VAC 0 VAC 0 VAC (Input ) 0 VAC 0 VAC 0 VAC atys a and. Voltage inputs. Voltage output A. without prior notice in view of continued improvement

14 Enclosed M Steel enclosure coff_5_a cat Modular design. Different optional accessories are available. Conformity to standards IEC 049 M s 0 VAC network No. of poles Enclosure IP4 Enclosure IP General characteristics From to 0 A. 0/400 VAC network +/ 0 % (standard). 7/0 VAC network for M e (on request). or 4 wires applications. Protection degree: IP4 (standard), IP55 (optional). Colour: RAL 705. Cable gland plate: top or bottom. Material: steel thickness.5 mm. Coating: epoxy polyester powder. Wall mouting: 4 wall mouting brackets suppliednot mounted. Door: solid with hinges, 45 mm cut out dimension, with glass for IP55 version. Locking system: mm doublebar key (key supplied). Miscellaneous: earth connection points, neutral on the right. Weight (without busbar support): kg ( kg for busbar support). Connection terminals (without busbar support): mm minimum Cu section, mm maximum Cu section. Options Auxiliary contact: integrate NOC per position (I, 0, II), per enclosure. Voltage sensing and power supply top: allow up to x.5 mm cable connection. Busbar support for Cu connection up to 0 mm. Sealable cover. M e 0/400 VAC network () No. of poles () 7/0 VAC network: on request. Factory fitted options Description Enclosure IP4 Enclosure IP55 Auxiliary contact voltage sensing and power supply Solid neutral Extension box () Sealable cover () Busbar support () For M s only. () For M e only ,5,5 atysm a cat without prior notice in view of continued improvement A.

15 to 00 A Accessories Enclosed Characteristics Enclosed s Steel enclosure coff_05_a cat NonAutomatic Transfer Switch. Compact design. Mechanically interlocked switching. Connection ready for external logic control. Conformity to standards IEC 049 General characteristics Adapted to mechanical risk and dust hazard. Protection degree: IP54 (standard device). Colour: RAL 705. Cable gland plate: top and bottom from to A, bottom from 400 to 00 A. Material: steel thickness mm. Coating: epoxy polyester powder. Wall mounting: 4 wall mounting brackets supplied not mounted (rating 400 A), floor standing feet (rating > 0 A). Door: solid with hinges. Locking system: mm doublebar key (key supplied). Miscellaneous: earth connection points, neutral on the right. Accessories: double power supply, nd auxiliary contact, solid neutral, 400/0 VAC transformers (on each network), positions padlocking,... Available on request Enclosures and specific connections: neutral on the left,... Standard device 0 VAC No. of poles Factory fitted accessories Description Double power supply nd auxiliary contact: from to 0 A nd auxiliary contact: from 800 to 00 A / 0 VAC transformer consult us positions padlocking Customer fitted accessories Solid neutral... 0 A A A A A A A A atys_9_d gb_cat H N M W Z Z () Wall mounting brackets delivered up to 400 A. () Floor standing feet from 0 A (add 00 mm for feet, at H dimension). () Mounting spacers. D Rating (A) Connection section (mm ) Max. connection section (mm ) H W D M N Z Z Weight (kg) x 85 x x 40 x x x00 / 4x x 85 x00 / 4x x 40 x85 / 4x A. 4 without prior notice in view of continued improvement

16 Enclosed e Steel enclosure coff_0_a cat Automatic Transfer Switch ATS. Compact design. Mechanically interlocked switching. Connection ready for external logic control. Conformity to standards IEC 0947 IEC 049 General characteristics Adapted to mechanical risk and dust hazard. Protection degree: IP54 (standard device). Colour: RAL 705. Cable gland plate: top and bottom from to A, bottom from 400 to 00 A. Material: steel thickness mm. Coating: epoxy polyester powder. Wall mounting: 4 wall mounting brackets supplied not mounted (rating 400 A), floor standing feet (rating > 0 A). Door: solid with hinges. Locking system: mm doublebar key (key supplied). Miscellaneous: earth connection points, neutral on the right. Accessories: nd auxiliary contact, solid neutral, 400/0 VAC transformers (on each network), positions padlocking,... Available on request Enclosures and specific connections: neutral on the left,... Standard device 0 VAC No. of poles Factory fitted accessories Description nd auxiliary contact: from to 0 A nd auxiliary contact: from 800 to 00 A / 0 VAC transformer consult us positions padlocking Customer fitted accessories Description D0 () D0 () RJ45 connection cable Communication RS485 MODBUS inputs / outputs Solid neutral (see page A.4 Enclosed s ) () RJ45 connection cable is required atys c gb_cat H N M W 80 Z.5 Z () Wall mounting brackets delivered up to 400 A. () Floor standing feet from 0 A (add 00 mm for feet, at H dimension). () D0 or D0 interfaces. D Rating (A) Connection section (mm ) Max. connection section (mm ) H W D M N Z Z Weight (kg) x 85 x x 40 x x x00 / 4x x 85 x00 / 4x x 40 x85 / 4x without prior notice in view of continued improvement A. 5

17 to 00 A Accessories Enclosed Characteristics Enclosed with isolation BYPASS Steel enclosure atys_7_a cat m Automatic Transfer Switch provides all functions required for break before make ATS applications. The SOCOMEC BYPASS system allows complete ATS isolation. Top and bottom isolation is achieved using the SOCOMEC +4 pole BYPASS switch up to 0 A. For the double line version during the ATS isolation, supply, selection remains possible thanks to a manual changeover. m associated to a D0 remote display allows configuration, operation and measurement from outside the panel (adjustable time/transfer delays and control level (U, F), generator start/stop control,...). Different optional accessories are available. Conformity to standards IEC 0947 IEC 049 IEC 059 General characteristics Product range From to 00 A, 4 pole, or 4 wires applications. 400/0 VAC +/ 0%, /0 Hz; self supplied from incoming sources. Main features ATS logic control sequence (dual source automatic changeover). phases voltage and frequency detection & phase rotation control of both sources. Generator start / stop relay output. ATS I, 0, II electrical control by volt free dry contacts. ATS Emergency manual operation. ATS position 0. Isolation bypass and manual changeover 0, I, II auxiliary contacts. ATS Auto / Manual key selector with auxiliary contact. Standard device 0 VAC No. of poles Double line Factory fitted accessories Description Customer fitted accessories Description Single line nd auxiliary contact ( per position) / 0 VAC transformer ( per network) consult us positions padlocking Clock exerciser with dataloging current transformers (CTs) consult us consult us Communication RS485 MODBUS inputs / outputs Solid neutral consult us Enclosure IP 4 protection rating as standard. Hinged door, double bar locking system. Wall mounting brackets delivered up to 400 A. Floor standing feet from 0 to 00 A rating. Terminals protection screen. Steel enclosure. RAL 705. Cable entry Bottom cable entry as standard. Specific cable entry requirements available upon request. Neutral position located on the right as standard. Alternative options available upon request. atys_77_a gb_cat SIRCOVER BYPASS ATS + 4 Up to 400 A From to 0 A optional control LOAD Q Earth connection Cu 5 x m Bypass ATS N Q Q SIRCOVER atys_78_a gb_cat. Grand plate Example: m 400 A double line version with isolation BYPASS in enclosure. 07. A. without prior notice in view of continued improvement

18 Enclosed with isolation BYPASS (continued) Steel enclosure Illustrations Operation ATS position: I, I, I : closed II: opened BYPASS position: I, I, I : opened II: closed For the double line version, I 4 or II closed depending on supply source required. from 5 to 0 A SINGLE LINE from 5 to 0 A DOUBLE LINE T T T T S S I I I I SIRCOVER 0 m ATS BYPASS m ATS BYPASS I II I4 II atys_7_a gb_cat I BYPASS ATS Load II atys_74_a gb_cat I BYPASS ATS Load II m m SIRCOVER + 4 pole SIRCOVER + 4 pole SIRCOVER 4 pole from 800 to 00 A SINGLE LINE from 800 to 00 A DOUBLE LINE T T T T SIRCO SIRCO I I I I ATS BYPASS ATS BYPASS SIRCOVER 0 m m I II I4 II SIRCOVER SIRCOVER atys_75_a gb_cat ATS BYPASS I Load II atys_7_a gb_cat ATS BYPASS I Load II m SIRCO 8 pole and SIRCOVER 4 pole m SIRCO 8 pole and SIRCOVER 4 pole SIRCOVER 4 pole without prior notice in view of continued improvement A. 7

19 to 00 A Accessories Enclosed Characteristics Enclosed with isolation BYPASS (continued) Steel enclosure D M W N H atys_708_a gb_cat.5. Remote interface D0. Up to 400 A. From 0 A Single line version Wall mounting Bottom Connection section (mm ) Max. connection section (mm ) H W D M N Floor standing Bottom Connection section (mm ) Max. connection section (mm ) H W x 85 x x 40 x x x Double line version Wall mounting Bottom Connection section (mm ) Max. connection section (mm ) H W D Floor standing Bottom Connection section (mm ) Max. connection section (mm ) H W D 0 x x x 85 x x 40 x x x D M M N M N N A. 8 without prior notice in view of continued improvement

20 Changeover switches Enclosed with isolation BYPASS (continued) Steel enclosure Environment The complete enclosure meets the following environmental requirements: operating temperature: 0 to +40 C without derating, operating temperature: +40 to +5 C with derating, maximum storage is one year, 80 % humidity non condensing at +55 C, Functional diagram Load 95 % humidity non condensing at +40 C, maximum operating altitude without switch derating is 000 m above sea level. C C A A B B Power 0 VAC Voltage sensing L L L N m 7 Power 0 VAC Voltage sensing L L L N A Manual changeover (only for the double line) Isolation BYPASS B+C SIRCOVER +4p (from A to 0A) B SIRCOVER 8p (from 800A to 00A) C SIRCOVER 4p (from 800A to 00A) atys_79_b gb_cat RJ RJ 5 Priority source Backup source : position 0 control : position I control : position II control 4: position control inhibition inputs (0III) 5: auxiliary contact, closed when the switch is in position I : auxiliary contact, closed when the switch is in position II 7: auxiliary contact, closed when the switch is in position 0 8: auxiliary contact, closed when the switch is on AUT mode 9: auxiliary contact, closed when the switch is padlocked 0: genset start command : auxiliary power supply (for optional modules control) : remote test onload input : DTT inhibit input. Transfer initiated as soon as the input is closed when DTT = max. value. 4: fault output 5: remote control interface : slots for optional modules 7: current transformers (Cts) for metering 8: bypass position 9: ATS position 0: Priority source used : Backup source used 0 0: supply 0 0% / 40 +0% 0 0: supply 0 0% / 40 +0% without prior notice in view of continued improvement A. 9

21 to 00 A Accessories Enclosed Characteristics M Characteristics (according to IEC 0947) Thermal current I th (40 C) Rated insulation voltage U i (V) (power circuit) Rated impulse withstand voltage U imp (kv) (power circuit) Rated insulation voltage U i (V) (operation circuit) Rated impulse withstand voltage U imp (kv) (operation circuit) Rated operational currents I e (A) 80 A 00 A 5 A According to IEC 0947 Rated voltage Load duty category A/B () A/B () A/B () A/B () A/B () 45 VAC AC A / AC B / 80/80 00/00 5/5 0/0 AC A / AC B / 80/80 00/00 5/5 0/0 AC A / AC B / 80/80 00/00 5/5 5/0 90 VAC () AC A / AC B / 80/80 00/00 5/5 0/0 AC A / AC B / 80/80 80/80 00/5 00/5 AC A / AC B / / 80/80 80/80 80/80 According to IEC VAC AC A / AC B / 80/80 00/00 00/5 00/0 AC A / AC B / 80/80 00/00 00/5 00/0 AC A / AC B / /80 /80 /80 /80 Overload capacity Rated shorttime withstand current s. I cw (ka rms) Shortcircuit making capacity (ka peak) () Prospective shortcircuit current (ka rms) () Associated fuse rated (A) () Connection Minimum Cu cable section (mm ) Maximum Cu cable section (mm ) Tightening torque min / max (Nm) Switching time (nominal voltage) I 0 or II 0 (ms) (4) I II or II I (ms) (4) Duration of electrical blackout I II (ms) minimum ( M s) 70 4/ / / / / 80 0 Duration of electrical blackout I II (ms) minimum ( M s or e) Powersupply tolerance Supply 0 VAC min / max (VAC) Control supply power demand Max current under 0 VAC (A) Nominal power (VA) 7/88 0 7/88 0 7/88 0 7/88 0 7/88 0 Mechanical characteristics Endurance (number of operating cycles) Weight switch (kg) A () A/B: Category with index A = frequent operation / Category with index B = infrequent operation. () With terminal shrouds or phase barrier. () For a rated operating voltage U e = 400 VAC. (4) Between the order given and the arrival in position (under the nominal conditions) A A. 40 without prior notice in view of continued improvement

22 Characteristics (according to IEC 0947) Thermal current I th (40 C) Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated operational currents I e (A) According to IEC 0947 Rated voltage 45 VAC AC A / AC B AC A / AC B AC A / AC B 90 VAC () AC0 A / AC0 B AC A / AC B AC A / AC B AC A / AC B 0 VDC DC0 A / DC0 B DC A / DC B DC A / DC B DC A / DC B 440 VDC DC0 A / DC0 B DC A / DC B DC A / DC B DC A / DC B According to IEC 0947 Overload capacity Rated shorttime withstand current s. I cw (ka rms) Rated peak withstand curent (ka peak) (5) Connection 400 A 0 A 800 A Load duty category A/B () A/B () A/B () Minimum Cu cable section (mm ) Minimum Cu busbar section (mm ) x x 0 x 5 x 85 x 40 x 5 x 40 x x 5 Maximum Cu cable section (mm ) Maximum Cu busbar width (mm) x 00 x 00 4 x 85 Tightening torque min / max (Nm) 9/ 9/ 0/ 0/ 0/ Switching time I II or II I (s) () I O or II O (s) () Powersupply tolerance Supply 0 VAC min / max (VAC) Control supply power demand Supply 0 VAC inrush / nominal (VA) Mechanical characteristics Endurance (number of operating cycles) Weight of switch ( ) (kg) Weight of switch ( ) (kg) 5 A A/B () A () A/B: Category with index A = frequent operation / Category with index B = infrequent operation. () With terminal shrouds or phase barrier. () pole device with pole in series for the + and pole for the. (4) 4pole device with pole in series by polarity. (5) For a rated operating voltage U e = 400 VAC. () Between the order given and the arrival in position (under the nominal conditions). A A/B () Prospective shortcircuit current (ka rms) (5) Associated fuse rated (A) (5) A 7/88 7/88 7/88 7/88 7/88 7/88 7/88 40/80 40/80 40/00 40/00 40/0 4/0 4/ A/B () 5/5 0/0 / 400/400 5/5 0/0 / 400/400 5/5 0/0 / / 5/5 0/0 / 400/400 5/5 0/0 00/ 00/ 5/5 5/5 5/0 5/0 /80 /80 00/5 00/5 5/5 0/0 / 400/400 5/5 0/0 / / 5/5 0/0 / / 5/5 5/5 00/00 00/00 5/5 0/0 / 400/400 5 () /5 () 5 () /5 () 00 () /00 () 00 () /00 () 5 () /5 () 5 () /5 () 00 () /00 () 00 () /00 () 5 (4) /5 (4) 5 (4) /5 (4) 00 (4) /00 (4) 00 (4) /00 (4) /0 0/0 0/0 0/0 0/0 5/5 0/00 0/0 0/0 0/0 0/0 0/0 0 () /0 () 0 () /0 () 0 (4) /0 (4) 45 VAC AC B Weight of switch ( ) (kg) Weight of switch ( ) (kg) A/B () 800/ / / / / / / / / / / /800 00/ 00/ 800/ / / / / / / / / / (4) /800 (4) 000 (4) /000 (4) 800 (4) /800 (4) 000 (4) /000 (4) 800 (4) /800 (4) 000 (4) /000 (4) Duration of electrical blackout I II (s) without prior notice in view of continued improvement A. 4

23 to 00 A Accessories Enclosed Characteristics Characteristics (according to IEC 0947) Thermal current I th (40 C) Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Maximum Cu cable section (mm ) Maximum Cu busbar width (mm) Switching time I II or II I (s) (5) I O or II O (s) (5) Powersupply tolerance Supply 0 VAC min / max (VAC) Control supply power demand Supply 0 VAC inrush / nominal (VA) Mechanical characteristics Endurance (number of operating cycles) Weight of switch ( ) (kg) Weight of switch ( ) (kg) A x A A 000 A 0 A x 85 x A 000 Rated operational currents I e (A) According to IEC 0947 Rated voltage Load duty category A/B () A/B () A/B () A/B () A/B () A/B () 45 VAC AC A / AC B / 00/00 800/800 /000 /0 /00 AC A / AC B / 00/00 800/800 /000 /0 /00 AC A / AC B / / / /00 /00 /00 90 VAC () AC0 A / AC0 B / 00/00 800/800 / / / AC A / AC B 800/ / /000 / / / AC A / AC B 800/ / /000 / / / AC A / AC B 00/ 0/0 0/0 / / / 0 VDC DC0 A / DC0 B / 00/00 800/800 / / / DC A / DC B / / / / / / DC A / DC B / / / / / / DC A / DC B / / / / / / 440 VDC DC0 A / DC0 B / 00/00 800/800 / / / DC A / DC B () / () () / () () / () / / / DC A / DC B () / () () / () () / () / / / DC A / DC B () / () () / () () / () / / / According to IEC VAC AC B Overload capacity Rated shorttime withstand current s. I cw (ka rms) Rated peak withstand curent (ka peak) (4) Prospective shortcircuit current (ka rms) (4) Associated fuse rated (A) (4) Connection Minimum Cu busbar section (mm ) x 0 x 5 x 80 x 5 x 00 x 5 x 00 x 0 x 00 x 0 x 00 x 0 Tightening torque min / max (Nm) 0/ 40/45 40/45 40/45 40/45 40/ Duration of electrical blackout I II (s).5.. () A/B: Category with index A = frequent operation / Category with index B = infrequent operation. () With terminal shrouds or phase barrier. () 4pole device with pole in series by polarity. (4) For a rated operating voltage U e = 400 VAC. (5) Between the order given and the arrival in position (under the nominal conditions). () Weight for e, e and m. 00 7/88 7/88 7/88 7/88 7/88 7/88 4/0 4/0 4/0 5/90 5/90 5/ () 5 () 57 () () Weight of switch ( ) (kg) () 5 () 59 () Weight of switch ( ) (kg) () () 9 () () 9 () A. 4 without prior notice in view of continued improvement

24 M to 0 A Cut out dimension atysm_008_a cat , atysm_04_a x_cat x M 4. Auxiliary contacts ( max.) ,5 5 to 0 A J M J U 4 W V AC AA BA CA Fix. 95 Fix. 80 = = 0 9 CA 0.5 Y Y X T T T F Z Z 5 A H C atys_08_e gb_cat Fix. 95 Fix. 80 Ø7 Ø9 W U CA. Locking bracket with padlocks max. Maximum handle radius, operating angle x 90. Connection and disconnection area 4. Mounting spacers 5. Terminal shrouds. Handle Rating Overall dimensions Terminal shrouds Switch body Switch mounting Connection terminals (A) A p. A 4p. C AC F p. F 4p. H J p. J 4p. J M p. M 4p. T U V W X p. X 4p. Y Z Z AA BA CA without prior notice in view of continued improvement A. 4

25 to 00 A Accessories Enclosed Characteristics 800 to 800 A 4 J M 5,5 U = 9 V atys_09_e x_cat,5 T T T F 000 to 00 A A M 5, I = AC B AA X,5 Z Y 5 Y 48 5, ,5. Locking bracket with padlocks max. Maximum handle radius, operating angle x 90. Connection and disconnection area 4. Terminal screens 5. Phase barrier shield. Handle Rating (A) Overall Terminal dimensions shrouds Switch body Switch mounting Connection terminals B AC F p. F 4p. J p. J 4p. M p. M 4p. T U V X Y Z AA atys_78_a x_cat ,5 45 4Ø 4.5 Ø Overall dimensions Switch mounting A p. A 4p. M p. M 4p A. 44 without prior notice in view of continued improvement

26 Cut out dimension 5 to 0 A 800 to 800 A s e, e, m s e, e, m Connection terminals 800 to 000 A A 00 to 00 A ø 9 x ø,5 5 5 svr_077_a x_cat,5 ø svr_078_b x_cat svr_098_a x_cat Copper bars connection kits Fig. Fig. Fig acces a cat 9 55 acces a cat 0 acces_4_a cat 5 acces b cat acces_9_a cat acces a cat atys_49_a x_cat,5 0 atys a x_cat,5 5 atys_5_a x_cat,5 atys_5_a x_cat,5 4 without prior notice in view of continued improvement A. 45

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

Enclosed changeover switches Automatic operation ATSE * - Automatic equipment from 40 to 3200 A Integrated products

Enclosed changeover switches Automatic operation ATSE * - Automatic equipment from 40 to 3200 A Integrated products ATSE * - Automatic equipment from 40 to 3200 A Integrated products & solutions The solution for > High Rise Buildings. > Data centres. > Energy production. > Healthcare buildings. > Banking and Insurances.

More information

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

Motorised and automatic transfer enclosed switchess

Motorised and automatic transfer enclosed switchess s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

What you need to know. Â Conformity to standards

What you need to know.  Conformity to standards SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

ATyS t M Automatic Transfer Switching Equipment

ATyS t M Automatic Transfer Switching Equipment Instruction Manual ATyS t M Automatic Transfer Switching Equipment www.socomec.com www.socomec.com www.socomec.com/en/atys-t-m To download, brochures, catalogues and technical manuals. 2 ATyS t M - 542

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty

More information

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A Integrated products & solutions The solution for > Iron and steel industry > Cement plants > Paper mills > Sawmills > Hydraulic power packs > Automotive > Mining coff_436_a coff_434_a Strong points Function

More information

CATALOGUE. Solutions for Power, Control & Safety

CATALOGUE. Solutions for Power, Control & Safety CATALOGUE Solutions for Power, Control & Safety 2015 Contents An independent manufacturer... p.4 Four key applications: the benefit of a specialist... p. 5 A cutting-edge laboratory... p. 6 Socomec in

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

ATS* By-Pass solution

ATS* By-Pass solution ATS* solution Other enclosed switches tablo_22_a_1_cat site_366_483_484_a Enclosed ATS from 4 to 32 A Function ing between 2 sources for reliability of the power supply. Single Line & ouble Line of the

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A 2017 CTLOGUE extract SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200 Transfer switches svr_207_a.eps svr_208_a.eps The solution for > Manufacturing > Power

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures coff_163_a_1_cat coff_156_b_1_cat Function equipped with SOCOMEC switches provide emergency breaking, breaking for mechanical maintenance and safety isolation in the vicinity of any low voltage final circuit.

More information

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Breakers and Switches. Switches Change-over and transfer switches

Breakers and Switches. Switches Change-over and transfer switches Breakers and Switches Switches Change-over and transfer switches Change-over and transfer switches 16...2500 A Contents: 4 Product overview, features 8 Technical data 8 Manual, motorized and automatic

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Breakers and Switches. Switches Switch-disconnectors OT and OTM Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

CATALOGUE MARINE APPLICATIONS. Energy performance solutions

CATALOGUE MARINE APPLICATIONS. Energy performance solutions CATALOGUE MARINE APPLICATIONS Energy performance solutions 2017 2018 Marine Certifications Our certified products As an independent manufacturer, we, at Socomec are committed to adapting the range and

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times. The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

Switch disconnectors

Switch disconnectors Selection Load break switch disconnectors type LK3, 40-120 A Selection guide for 3 and 4-pole switch disconnectors General The LK3 range of switch disconnectors (lth: 40 A to 120 A) is designed for use

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

General Characteristics

General Characteristics from 63 to 31 lbs_037_a he solution for > ain switchboard > Distribution panel > Emergency switching > us tie Function he CEC ensures making and breaking on load and security breaking of any low voltage

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Switch-disconnectors OT , OETL 3150

Switch-disconnectors OT , OETL 3150 Switch-disconnectors OT 16...2500, OETL 3150 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 Front operated switch-disconnectors OT, OETL 24 Side operated

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Series 230 Automatic Transfer Switch

Series 230 Automatic Transfer Switch Series 230 Automatic Transfer Switch Product overview The Series 230 automatic transfer switch consists of an intelligent controller and a modular load break switch which automatically transfers the load

More information

Transfer switching solutions

Transfer switching solutions CATALOGUE EXTRACT Transfer switching solutions from 40 to 6300 A 2018 Contents The SOCOMEC Group... Security and reliability for your transfer applications... Remotely operated and Automatic Transfer

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Switching, control and protection solutions for solar applications

Switching, control and protection solutions for solar applications Switching, control and protection solutions for solar applications continuous performance www.socomec.com Summary SIRCO M PV Manually operated modulable and modular switches p. 4 SIRCO MV PV Manually

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

Synergy EN product information

Synergy EN product information Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on

More information

Euroload Changeover Switch

Euroload Changeover Switch Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.

More information

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block. PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue FAQs I have installed the ATS panel but it won t go into the mains supply? First check all cables are in place and properly installed and that the control fuses (A-C on page 4) have not blown. If it still

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted 110 The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information