1 BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting sets...69 Accessories...7 Purchase order example...7 TECHNICAL INFORMATION Circuit breakers, switch-disconnectors - specifications wiring diagram connecting, installation de-ionization space dimensions...79 Overcurrent releases - description, specifications, characteristics...85 Connecting sets Switches Shunt trips - specifications specifications specifications...86 Undervoltage releases - specifications...86 Hand drives Motor drives - description description, specifications, wiring diagram
2 BA5*37 SUMMARY OF MODELS AND ACCESSORIES CONNECTING SETS Front connection CS-37-PP5 CS-37-PP4 CS-37-PP6 Front connection CS-37-PP CS-37-ZP3 CS-37-PP7 CS-37-ZP Rear connection CS-37-PP8 CS-37-ZP9 CS-37-PP8 CS-37-W4 CS-37-W5 CS-37-2W6 Clamp type terminals CS-37-V3 FIXED DESIGN FIXED DESIGN, MOTOR DRIVE FIXED DESIGN, FRONT HAND DRIVE BA5* BA5* BA5* FIXED DESIGN, FRONT HAND DRIVE WITH ADJUSTABLE LEVER BA5* ACCESSORIES Terminal cover IP Locking inset Mounting sets OD-37-KS OD-37-UV OD-37-MS2 Circuit breakers BA5*37 and switch-disconnectors BN5.37 are designed for direct replacement of obsolete BA5*37 and BN5.37 units 67
3 BA5*37 - Commercial information TYPE DESIGNATION SPECIFICATION FOR ORDERING Selection of accessories for circuit breakers and switch-disconnectors FOR TECHNICAL INFORMATION, see page BA5- Circuit breaker up to 4 A for protection of LINES 72 BA5G Circuit breakers up to 4 A for protection of MOTORS 72 BN5. Switch-disconnector up to 4 A 72 Fixed design, front connection 75 Withdrawable design, front connection 755 Withdrawable design, front connection, test position signalling 756 Withdrawable design, front connection, lockable test position 757 Withdrawable design, front connection, lockable test position with signalling 76 Withdrawable design, rear connection 765 Withdrawable design, rear connection, test position signalling 766 Withdrawable design, rear connection, test position signalling 767 Withdrawable design, rear connection, lockable test position with signalling 77 Plug-in design, front connection 78 Plug-in design, rear connection No accessories 4 Auxiliary switch Auxiliary switch 22, relative switch 86 Undervoltage release 86 4 Undervoltage release, auxiliary switch Undervoltage release, auxiliary switch 22, relative switch 86 2 Shunt trip Shunt trip, auxiliary switch Shunt trip, auxiliary switch 22, relative switch 86 Circuit breaker and switch-disconnector designs Rated current No accessories 85 Lateral hand drive ) Lateral hand drive, adjustable lever ) Lateral hand drive, lock ) Lateral hand drive, adjustable lever, lock ) Front hand drive ) Front hand drive, adjustable lever ) Front hand drive, lock ) Front hand drive, adjustable lever, lock ) Front hand drive for plug-in design, adjustable lever, lock ) Motor drive Motor drive with operations counter =>> CIRCUIT BREAKER AND SWITCH-DISCONNECTOR DESIGNS Selection of circuit breaker rated current Circuit breakers are supplied with releases in standardized series of rated currents - regulation I n = - 25% (values are found in Table). As regards ordering, the rated current of a release is selected so that its value is put down after the circuit breaker design. Example: BA5-37-, I n = 25 A - circuit breaker of fixed design; no accessories; 25 A rated current of the release; protection of lines. FOR TECHNICAL INFORMATION, see page 85 ) - it is necessary to put down your requirement for the red lever in your purchase order I n [A] I r [A]
4 CONNECTING SETS BA5*37 - Commercial information Type Product code Description S [mm 2 ] Connection Weight [kg] Packing [set] ) CS-37-PP Front connection up to 63 A 25 Cu cables.8 CS-37-PP4 549 Front connection up to 2 A Cu/Al busbars, cable lugs.45 CS-37-PP Front connection up to 2 A Cu/Al busbars, cable lugs.4 - with a welded nut CS-37-PP3 549 Front connection up to 4 A Cu/Al busbars, cable lugs.45 CS-37-PP Front connection up to 4 A Cu/Al busbars, cable lugs.42 - with a welded nut CS-37-PP 5489 Front connection up to 4 A Cu/Al busbars, cable lugs.75 CS-37-PP Front connection up to 4 A Cu/Al busbars, cable lugs.72 CS-37-ZP9 759 Rear connection up to 2 A Cu/Al busbars, clamp type terminals - For DIMENSIONS, see page CS-37-ZP 7592 Rear connection up to 4 A Cu/Al busbars, clamp type terminals - For DIMENSIONS, see page 75. CS-37-ZP 7593 Rear connection up to 4 A Cu/Al busbars, clamp type terminals - For DIMENSIONS, see page 75 ) - one set makes possible to connect one end of the circuit breaker (the set contains three terminals with necessary connection accessories) 69
5 BA5*37 - Commercial information CONNECTING SETS Type Product code Description S [mm 2 ] Connection Weight [kg] Packing [set] ) CS-37-V Clamp type terminals up to 6 A - FOR TECHNICAL INFORMATION, see page Cu/Al cables.3 CS-37-W Clamp type terminals up to 2 A - FOR TECHNICAL INFORMATION, see page Cu/Al cables.5 CS-37-W5 5 Clamp type terminals up to 35 A - FOR TECHNICAL INFORMATION, see page Cu/Al cables.53 CS-37-2W6 53 Clamp type terminals - double up to 4 A - FOR TECHNICAL INFORMATION, see page - it is necessary to use the OD-37-MS2 mounting set 2x 24 Cu/Al cables.9 ) - one set makes possible to connect one end of the circuit breaker (the set contains three terminals with necessary connection accessories) ACCESSORIES Type Product code Description Weight [kg] Packing OD-37-MS Mounting set - holder to fix the circuit breaker.2 OD-37-KS 83 Terminal cover - insulating the terminals from one another within de-ionisation space - included in every supply of circuit breakers.2 OD-37-UV 7596 Locking inset - enables the circuit breaker lever to be locked in switched off manually state.2 7
6 BA5*37 - Commercial information PURCHASE ORDER EXAMPLE You need a circuit breaker to protect a plant with compressors where the rated current varies around 3 A. The circuit breaker will be installed in a cubicle switchgear, input and output lines of the circuit breakers will be made by Cu busbars. You wish to switch the circuit breaker with the emergency STOP push button using a shunt trip, to switch it off remotely through the motor drive and to indicate the state of the main contacts. Your purchase order: (do not enter the greyed text in your purchase order) ) pc BA5G I n = 4 A - circuit breaker with the tripping characteristic for protection of motors in fixed design with a shunt trip, auxiliary switch and motor drive, rated current of the overcurrent release 4 A and rated short-circuit ultimate breaking capacity 36 ka/ac 45 V 2) shunt trip AC 23 V - rated voltage of the shunt trip 3) motor drive AC 23 V - rated voltage of the motor drive 7
7 CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Specifications BA5*37 - Technical information CIRCUIT BREAKERS SWITCH- DISCONNECTORS Type BA5-37, BA5G37 BN5.37 Dimensions A x B x C + D [mm] x 225 x x 225 x Weight m [kg] Standards EN IEC EN IEC Approval marks Dimensions Load Wiring for DC circuits Number of poles 3 3 Rated current I n [A] 4 4 Rated operating voltage AC DC U e [V] U e [V] max. 69 max. 44 max. 69 max. 44 Rated frequency f n [Hz] /6 /6 Rated pulse withstand voltage U imp [kv] 8 8 Rated isolation voltage U i [V] Utilization category (selectivity) AC 69 V A - Utilization category (switching mode) Rated short-time withstand current U e = AC 69 V Rated short-circuit ultimate breaking capacity Off-time at I cu AC DC AC 69 V DC 44 V - - AC-23B DC-23B I cw [ka] / t [s] - 8/ I cu see page 73 - [ms] [ms] Rated short-circuit service I cs see page 73 - breaking capacity Rated short-circuit making capacity I cm [ka] / U e [V] see page 73 6 / 4 Losses per pole at I n = 4 A [W] Mechanical endurance [contact making] Electric endurance [contact making] 2 2 Frequency of switching [contact making/hr] 2 2 Operating force [N] Protection from the front of the unit Terminal protection IP, IP2, IP66 ) IP, IP2, IP66 ) Operating conditions Reference ambient temperature [ C] 4 4 Ambient temperature range [ C] Working environment standard standard Max. sea level [m] 2 2 Seismic immunity.5g (8 Hz).5g (8 Hz) Design modifications Front/rear connections / / Plug-in design Withdrawable design Accessories Switches - / / / / / / auxiliary/relative/signal/early Shunt trip Undervoltage release/with early switch / / Front hand drive/with adjustable lever/ / / / / lateral hand drive Motor drive/with operations counter / / Locking type lever available, unavailable ) - upon agreement with the manufacturer
8 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Specifications Rated short-circuit ultimate breaking capacity I cu [ka] (rms value) - standard/reverse wiring I n [A] U e AC 23 V AC 45 V AC V AC 69 V DC 22 V DC 44 V 4/4 5/5 5/5 4/2 2/2 2/ /4 25/2 2/2 4/2 2/2 2/2 8; 55/4 25/2 25/2 4/2 2/2 2/ /4 36/3 25/2 4/2 2/2 2/2 2; 35 55/4 36/3 25/2 4/2 2/2 2/2 4 55/4 36/3 25/2 4/2 2/2 2/2 Rated short-circuit service breaking capacity I cs [ka] (rms value) - standard/reverse wiring I n [A] U e AC 23 V AC 45 V AC V AC 69 V DC 22 V DC 44 V 5/5 3/3 3/3 / 2/2 2/2 63 5/5 3/3 3/3 / 2/2 2/2 8; 5/5 3/3 3/3 / 2/2 2/ /5 3/3 3/3 / 2/2 2/2 2; 35 5/5 3/3 3/3 / 2/2 2/2 4 5/5 9/9 7/7 4/4 2/2 2/2 Rated short-circuit making capaity I cm [ka] (peak value) - standard/reverse wiring I n [A] U e AC 23 V AC 45 V AC V AC 69 V DC 22 V DC 44 V 84/84 3/3 3/3 28/28 2/2 2/2 63 2/84 52/42 42/42 28/28 2/2 2/2 8; 2/84 52/42 52/42 28/28 2/2 2/ /84 75/63 52/42 28/28 2/2 2/2 2; 35 2/84 75/63 52/42 28/28 2/2 2/2 4 2/84 75/63 52/42 28/28 2/2 2/2 Power losses I n [A] P [W] losses per circuit breaker pole 73
9 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Wiring diagram Circuit breaker L (+) Q3 ON OFF B X3 C C2 M L A/B X A/B S9 For F2 A F F2 A2 B B2 V X Q X2 3 3 S 3 3 S2 O - BA5.37 circuit breaker body Q - circuit breaker BA5.37 V - trip-free mechanism X - power terminals of the plug-in or withdrawable device X2 - auxiliary circuitry terminals of the plug-in or withdrawable device S9 - relative switch S, S2 - auxiliary switches F - undervoltage release F2 - shunt trip S4 - signalling of position taken MP - motor drive X3 - motor drive terminal board B - recommended wiring for motor drive Q3 - motor drive circuit breaker ON - motor drive ON button OFF - motor drive OFF button MP J 95 A2/B PE PE X3 N (-) N X2 95 A2/B2 S4 2 4 X X Switch-disconnector L(+) Q3 ON OFF B X3 C C2 M L A/B X A/B S9 For F2 A F F2 A2 B B2 V X Q X2 3 3 S 3 3 S2 O - BN5.37 switch-disconnector body Q - switch-disconnector BN5.37 V - trip-free mechanism X - power terminals of the plug-in or withdrawable device X2 - auxiliary circuitry terminals of the plug-in or withdrawable device S9 - relative switch S, S2 - auxiliary switches F - undervoltage release F2 - shunt trip S4 - signalling of position taken MP - motor drive X3 - motor drive terminal board B - recommended wiring for the motor drive Q3 - motor drive circuit breaker ON - motor drive ON button OFF - motor drive OFF button MP O 95 A2/B PE PE X3 N (-) N X2 95 A2/B2 S4 2 4 X X
10 BA5*37 - Technical information CIRCUIT-BREAKERS, SWITCH DISCONNECTORS Specifications States of switches Switch S, S2 S9 Circuit-breaker state Lever position of circuit breaker State of the main contacts Switch name Switch designation Switch function Relative S9 indicates switching the circuit breaker off by releases Auxiliary S, S2 indicates the position of main contacts Switched on Switched off manually Switched off by releases note: - contact open, - contact closed Connecting and installing Power circuit is connected using Cu, Al busbars, flexibars or cables, eventually by means of cables with lugs to provide wider choice of connecting, the following connecting sets are made, see page69 the feed lines are connected to input terminals, 3, 5 the load lines are connected to output terminals 2, 4, 6 the exchange of input and output terminals is allowed, accepting the fact that the rated short-circuit ultimate breaking capacity may be reduced in some cases (see page 73) it is recommended to apply paint on the busbars input and output conductors/busbars must be reinforced so as to avoid of transferring electrodynamic forces into the circuit breaker during short-circuits Recommended cross-sections of connecting cables and busbars I n [A] Cable S [mm 2 ] Busbars W x H [mm] Cu Al Cu Al x 2 6 x x 2 2 x x 3 25 x x 5 2 x x 5 25 x x 95 24; 2 x 2 32 x 5 32 x 8 4 2x 2 3; 2 x 32 x 6 32 x 8 Auxiliary circuits - fixed design by Cu conductors mm 2 in the device terminal Auxiliary circuits - motor drive by Cu conductors.5 mm 2 in a socket, which is part of the drive identification of terminals is found on the spaghetti insulation of single conductors the drive is provided with the PE terminal Auxiliary circuits plug-in and withdrawable designs with Cu conductors.5 mm 2 in the socket located on the withdrawable device identification of terminals is found on the spaghetti insulation of single conductors the side plates of the withdrawable unit are conductively connected and provided with the PE terminal Connecting sets specifications Cable S [mm 2 ] Core type Sector-shaped conductor stranded Sector-shaped conductor solid Round conductor stranded Round conductor solid Type I max [A] CS-37-V Cu / Al Cu / Al 6 Cu / Al 6 Cu / Al CS-37-W Cu / Al 95 3 Cu / Al 85 Cu / Al 7 24 Cu / Al CS-37-W Cu / Al 95 3 Cu / Al 85 Cu / Al 7 24 Cu / Al CS-37-2W6 4 2 x ( ) Cu / Al 2 x ( 2 3 ) Cu / Al 2 x ( 85 ) Cu / Al 2 x ( 7 24 ) Cu / Al 75
11 BA5*37- Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Connecting, installation Front connection 76
12 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Connecting, installation Front connection Rear connection 77
13 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS De-ionization space A, B, C minimum de-ionization space free of grounded metal structures When distances A, B, C are not adhered to, it is necessary to supply the metal structure of the switchgear with a flameproof insulation cover the terminal cover OD-37-KS is included in every circuit breaker supply For U n V, the conductors must be insulated among themselves at input terminals as far as 2 mm away from the circuit breaker. 78
14 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, front connection Drilling positions xM R M2-35 4A M - 2A Fixed design, rear connection Drilling positions 6 -: 2A : 4A 4xM5 6xØ26 -: 2A 6xØ : 4A M6 35-4A M2-2A : :
15 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design on C strips, rear connection 7 48 M OD-37-MS OD-37-MS2 3 Fixed design, front hand drive Drilling positions SWITCHGEAR DOOR 49 4xM MIN MAX WITHOUT SHAFT IP55 PROTECTION OF ROTARY HANDLE EXTENSION SHAFT ADAPTATION Ø3.2 2xØ4.8 - FOR LOCK 4 SHAFT END 23 2 R5 3x Ø46 8 SWITCHGEAR DOOR ADAPTATION 2xØ3. - FOR LABEL Ø29 8 MIN. MIN.8 FOR LOCK 33 92
16 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, lateral hand drive Drilling positions SWITCHGEAR DOOR 4xM MIN.9 MAX WITHOUT SHAFT IP55 PROTECTION OF ROTARY HANDLE EXTENSION SHAFT ADAPTATION SWITCHGEAR DOOR ADAPTATION Ø3.2 2xØ3. - FOR LOCK 2xØ4.8 - FOR LABEL 4 SHAFT END 93 3x2 Ø29 2 Ø R Withdrawable design, front and rear connections Drilling positions C 57 D F E 5 A B ±5 ~3 Ø9.5 75±5 E G 95 A B C D E F G 35-4 : A M : A M
17 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Withdrawable design, front hand drive with adjustable lever C 57 D SWITCHGEAR DOOR ADAPTATION 2xØ4.8 - FOR LOCK 2xØ3. - FOR LABEL ~3 Ø9.5 75± R5 3x Ø46 8 A B 2 77 E G F E MIN MAX Ø29 EXTENSION SHAFT ADAPTATION Ø3.2 4 SHAFT END 33 MIN. MIN.8 FOR LOCK 92 A B C D E F G 35-4 : A M : A M
18 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Withdrawable design, front and rear connections 25 2 CHECKING POSITION ISOLATED (DISCONNECTED) POSITION OPERATING POSITION Drilling positions ~3 Ø9.5 75± Fixed design, motor drive REMOVABLE ROTARY HANDLE Connector attachment xØ ~8 M5 43 Ø
19 BA5*37 - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Withdrawable design, front and rear connections, motor drive 25 2 C D 5 CHECKING POSITION ISOLATED (DISCONNECTED) POSITION OPERATING POSITION A B ±5 5 E 2 6 F G E Drilling positions ~3 Ø A : A B C 32 D E 25 M2 F G A : M
20 BA5*37 - Technical information OVERCURRENT RELEASES Description In relation to the protected circuit required, the rated current I r of the dependent release will be set up accordingly (the maximum value is set up by the manufacturer and the adjustment of currents within the marked range is linear). I r = (.75 - ) x I n Setting of reduced current Ranges of overcurrent releases and their applicable adjustment (at 4 C) Dependent Independent I n [A] I r [A] I rm [A] I rm [A] BA5-37 BA5G Rated currents versus ambient temperature I n [A] I nϑ [A] + 55 C + 4 C + 2 C - C Characteristics COLD START COLD START WARM START WARM START 85
21 BA5*37 - Technical information AUXILIARY SWITCHES S S S Specifications Type auxiliary relative Rated operating voltage AC U e [V] Rated isolation voltage U i [V] AC 4 AC 2 Rated frequency f n [Hz] /6 /6 Rated operating current AC I e [A]/U e [V] (AC 5) 6 / 23 5 (AC 2) 6 / 4 Thermal current I th [A] 5 Arrangement of contacts 22 Connection cross-section S [mm 2 ] 2 x ( ) 2 x ( ) Arrangement of contacts Number of contacts Contact types change-over break + make Switch name Switch designation Switch function Relative S9 indicating switching the circuit breaker off by releases Auxiliary S, S2 indicates the position of main contacts SHUNT TRIPS B2 F2 B Fig. - Recommended wiring B2 S F2 2 B OFF Specifications Type Operational voltage AC U e [V] 24, 48,, 23, 4, DC U e [V] 24, 48,, 22 Rated frequency f n [Hz] /6 Input power at. U e AC [VA] DC [W] Characteristic 8 9 U.7 U e the circuit breaker must trip Loading time [s] max. - for recommended wiring, see Fig. UNDERVOLTAGE RELEASES A2 F A Specifications Type Operational voltage AC U e [V] 24, 48,, 23, 4, DC U e [V] 24, 48,, 22 Rated frequency f n [Hz] /6 Input power at. U e AC [VA] DC [W] Characteristic ) 6 3 U.85 U e - circuit breaker can be switched on U.35 U e -the circuit breaker must trip unlimited Loading time ) - switching off of the release may be delayed using the delay unit BA-BL-X23, for more detailed information, see page27 86
22 HAND DRIVES BA5*37 - Technical information Fig. - Front hand drive Description The hand drive makes possible to govern the circuit-breaker by rotating the lever, e.g. to switch machines on and off. When a circuit breaker is ordered along with the hand drive, this unit will be installed in the circuit breaker by manufacturer and supplied complete. The hand drive with the so called adjustable lever is provided with an extra supply of an extension shaft and a bearing with an operating lever. The hand drive makes it possible to control the circuit breaker: a) from the front panel of the circuit breaker(fig.) - design: BA5*37-*****86 - for dimensions, see page 8 b) through the switchgear door (Fig. 2) - design: BA5*37-*****86 - for dimensions, see page 8 c) from the side of the circuit breaker - design: BA5*37-*****85 d) through the side wall of the switchgear - design: BA5*37-*****85 The hand drive bearing is attached to the switchgear door and provides protection IP55. Enhanced safety for personnel operating electric equipment It is possible to lock the circuit breaker if the hand drive lever is provided with a lockable mechanism (for the supply number, refer to page 68). Locking is feasible using a padlock while the circuit breaker is in load state ( switched off manually ) Fig. 2 - Front hand drive with adjustable lever 87
23 BA5*37 - Technical information MOTOR DRIVES Description The motor drive enables the circuit breaker to be controlled (switched on/off) remotely by electric voltage. It is well exploited in automated plants. If a circuit breaker is ordered with a motor drive, the unit will be installed in the circuit breaker by the manufacturer. Upon agreement with the manufacturer, the drive unit may be supplied with an operations counter. Times for switching the circuit breaker on and off by means of the drive unit including necessary pulses are given in table Specifications. If faster tripping is required, the circuit breaker with motor drive may be furnished with a shunt trip or an undervoltage releases. The rated current of the circuit breaker can be controlled from the motor drive front panel. The panel has also an opening for a detachable lever by which the circuit breaker may be controlled even without any supply voltage. The front panel is also equipped with mechanical signalization of circuit breaker status. If a circuit breaker is switched off by any of the releases, the motor drive automatically loads the circuit breaker up to position ( Switched off manually ). A cable ended with a connector for connecting control circuits is part of the motor drive unit. For dimensions, see page 83 Specifications Type Operational voltage U e [V] U e [V], 23, 22 Rated frequency f n [Hz] / 6 Control pulse length for switching on [ms] >3 Control pulse length for switching off [ms] >3 Time to switch-on [ms] 8 Time before switching off [ms] 6 Frequency of ON / OFF cycles [contact making/hr] 3 Frequency of ON/OFF cycles - immediately one after another [contact making] 5 Mechanical endurance [contact making] Input power AC DC [VA] [W] 3 3 Protection AC DC AC DC V, 23 V V, 22 V LSN.8D/, LSN.4C/ Circuit breaker switched on by motor drive Main contacts Auxiliary switch Auxiliary switch Relative switch Relative switch t [ms] 88
24 MOTOR DRIVES Specifications BA5*37 - Technical information Circuit breaker switched off by motor drive Main contacts Circuit breaker switched off by auxiliary release and switched on by motor drive Main contacts Auxiliary switch Auxiliary switch Auxiliary switch Auxiliary switch Relative switch Relative switch Relative switch Relative switch t [ms] t [ms] Wiring diagram L(+) B Q3 ON OFF X3 C C2 L Diagram description Symbol Description MP motor drive M motor X3 motor drive terminal board B recommended wiring ON push-button OFF push button Q3 motor drive circuit breaker M MP PE N PE X3 N (-) 89
COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33
BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting
More informationMOULDED CASE CIRCUIT BREAKERS BC160N
D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage
More informationMOULDED CASE CIRCUIT BREAKERS BH630N, BH630S
MOULDED CASE CIRCUIT BREAKERS BH6N, BH6S F BH6N, BH6S COMMERCIAL INFORMATION Switching units, withdrawable device, plug-in device...f4 Switch-disconnector unit...f6 Connecting sets...f7 Mounting sets...f9
More informationModeion MOULDED CASE CIRCUIT BREAKERS BL1600S
H MOULDED CASE CIRCUIT BREAKERS BL6S H BL6S COMMERCIAL INFORMATION Switching units, withdrawable device...h4 Overcurrent releases...h5 Signalling units...h5 Residual current monitor...h6 Current transformers
More information3VT Kompaktleistungsschalter bis 630A
Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical
More informationMOULDED CASE CIRCUIT BREAKERS BC160N
D MOULDED CASE CIRCUIT BREAKERS BC6N Tento výrobek byl vyvinut za finanční podpory ze státních fondů prostřednictvím Ministerstva průmyslu a obchodu. D BC6N COMMERCIAL INFORMATION Circuit breakers...d4
More informationMOULDED CASE CIRCUIT BREAKERS BL1600S
H MOULDED CASE CIRCUIT BREAKERS BL6S H BL6S COMMERCIAL INFORMATION Switching units, withdrawable device, plug-in device...h4 Overcurrent releases...h Signalling units...h Connecting sets...h6 Switches...H8
More informationFuse switch-disconnectors
Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationFuse switch-disconnectors
Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationVarius SUMMARY OF MODELS
SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link
More informationVarius SUMMARY OF MODELS
Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00
More informationBasic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors
MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided
More information3VT5 Molded Case Circuit Breakers up to 1600 A
VT Molded Case Circuit Breakers up to 6 A Catalog General data Siemens AG Overview Connecting sets 4 Switching unit 6 7 8 9 6 4 Accessories 7 8 9 4 NSO_9a 4 6 7 8 9 Molded case circuit breaker Multiple
More information3VT2 Molded Case Circuit Breakers up to 250 A
VT Molded Case Circuit Breakers up to 5 A Catalog VT Molded Case Circuit Breakers up to 5 A General data / - Overview Circuit breakers Switch disconnectors / - Overview / - Selection and ordering data
More information3VT5 Molded Case Circuit Breakers up to 1600 A
VT5 Molded Case Circuit Breakers up to A Catalog Technical Information VT5 Molded Case Circuit Breakers up to A General data /2 - Overview Standard circuit breakers, releases / - Selection and ordering
More information3VT1 Molded Case Circuit Breakers up to 160 A
Siemens AG 4 VT Molded Case Circuit Breakers up to 6 A Catalog Technical Information VT Molded Case Circuit Breakers up to 6 A / General data / Circuit breakers Switch disconnectors Accessories and Components
More informationVarius SUMMARY OF MODELS
SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More information3VU13, 3VU16 Circuit-Breakers
3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used
More informationConnecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K
Varius SUMMARY OF MODELS OF FUSE-RAILS Type FSR00 FSR1 FSR2 FSR3 Rated operating current I e 160 A 250 A 400 A 630 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V Size 00 1 2 3 Busbar spacing
More informationDevices for switching and control
Devices for switching and control WWWOEZCOM Motor starters MOTOR STARTERS SM Basic function Switching and protection of motors up to 2 A Protection against short-circuit and protection against overload
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationIP20 degree of protection; IP40 degree of protection after installation in a distribution box
RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance
More informationSENTRON 3VT Molded Case Circuit Breakers up to 1600 A
Siemens AG 4 SENTRON VT Molded Case Circuit Breakers up to 6 A Catalog LV 6 4 VT Molded Case Circuit Breakers up to 6 A VT Molded Case Circuit Breakers up to 5 A The products and systems described in this
More informationDATA SHEET 3VT3 MCCB ACCESSORIES
Issued June 7 DATA SHEET VT MCCB ACCESSORIES Based on Siemens Catalog LV 8 VT Molded Case Circuit Breakers up to A 7 Accessies and Components es Overview Type designation accding to contact arrangement
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationRESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)
Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE ( ka) The device is a combination of residual current circuit breaker and circuit breaker For
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationMS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories
Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationRESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE
OLE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE-10B-1N-030AC The device is a combination of residual current circuit breaker and circuit breaker.
More informationPIX-H Metal-clad switchgear up to 17.5kV
AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...
More informationMotorized switch-disconnectors OTM 40 to 125 Amperes
Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution
More informationFuse switch disconnectors
SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY
More informationFuse switch disconnectors
SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationMC FRAME SIZE 1 / UP TO 160A
8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationMoulded case circuit breakers
Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationMS25, MST25, MS20, MST20
Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers
More informationResidual current circuit breakers with conditional shortcircuit
LFE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS LFE Residual current circuit breakers with conditional shortcircuit current 6 ka. They react to sine-wave residual current (type
More informationMotor Circuit Breakers C4
Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationTechnical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products
94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation
More informationMotor Circuit Breakers C3
Motor Circuit Breakers C3 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes
More informationvertical fuse switch disconnectors
SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationMCCB Accessories to suit AF
MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal
More information125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request
125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for
More informationSiemens AG VT3 Molded Case Circuit Breakers up to 630 A
Siemens AG VT Molded Case Circuit Breakers up to 6 A Catalog General data Overview Connecting sets 5 6 Switching unit 7 8 9 Accessies f plug-in and withdrawable devices 9 5 7 8 5 Accessies 6 6 7 8 9 NSO_a
More informationDRX 100 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationThermal magnetic and trip-free switches
87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/
More informationSENTRON VL Series Product Specifications
SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped
More informationElectronic circuit breaker EBU10-T
Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions
More informationCPG.0 Single busbar gas-insulated cubicles
MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation
More informationSelective main circuit breakers S 750 series Technical Data
Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.
More informationDRX 250 B/N/H Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.
More informationVarius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50
SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS Type SPB SPB SPF SP4.. SP50 Rated current I n 60 A / 0 A / 400 A 60 A / 0 A / 400 A 60 A / 0 A / 400 A / / 60 A Rated voltage AC/DC U n 690 V 690 V 690 V
More information15-I73E CAT REF.
& www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More informationNH-Fuse system Low voltage
38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories
More information14-I73E CAT REF.
& www.terasaki.co.jp -I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers
More informationRESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)
Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka) They react to both alternating sine-wave residual current and pulsating direct current (type A) For protection: against accidental
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More informationLow voltage moulded case circuit breaker EB2
Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation
More informationSwitch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV
Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads
More informationMULTIVERT 250A Size 1, 690VAC
MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.
More information18-I73E CAT REF.
& www.terasaki.co.jp 1-I73E CAT REF. TABLE OF CONTENTS General 1-1 Introduction 1- General 1-3 Selection Chart 1- Ratings and Specifications -1 Air Circuit Breakers for DC350V-00V - Moulded Case Circuit
More informationSystem pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489
Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationCircuit breakers for power distribution A1 Ordering information
Circuit breakers for power distribution A1 Ordering information A1 100A - Fixed (F) 1 pole - Front terminals (F) Thermomagnetic trip unit - TMF Icu (240 V) In I3 A (10kA) N (18kA) 15 400 A1A015TW-1 A1N015TW-1
More informationSiemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage
SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationRESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)
Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) Standard type for common use in building and housing installations up to 3 A, 230/400 V a.c. They react to alternating sine-wave
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More informationAir Circuit Breakers
Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More information3VT3 Molded Case Circuit Breakers up to 630 A
Siemens AG 4 VT Molded Case Circuit Breakers up to 6 A Catalog Technical Infmation VT Molded Case Circuit Breakers up to 6 A / General data / Circuit breakers Switch disconnects Accessies and Components
More informationSiemens AG WT Air Circuit Breakers up to 4000 A. Catalog LV SENTRON. Answers for infrastructure.
3WT Air Circuit Breakers up to 4000 A Catalog LV 35 011 SENTRON Answers for infrastructure. Related catalogs Low-Voltage Power Distribution and LV 10.1 Electrical Installation Technology Protection, Switching,
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased
More informationMedium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU
Medium Voltage Distribution PIX Air Insulated Switchgear up to kv PIX Air Insulated Switchgear up to kv The PIX system has been designed in accordance with international (IEC) standards, and gives an optimal
More informationAir Circuit Breakers
Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationTechnical Data Accessories MCBs Ex9B.
Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO
More information