Varius SUMMARY OF MODELS

Size: px
Start display at page:

Download "Varius SUMMARY OF MODELS"

Transcription

1 SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size a Fuse-link size /00 2 4a Utilization category at AC 400 V AC-2B AC-2B AC-2B AC-2B AC-2B AC-22B Accessories Remote signallings of cover position OD-FH-SK EMV-LTL4a Connecting sets CS-FH , Nx0-FH000 CS-FH CS-FH2-..., CS-FH2-... CS-FH2-..., CS-FH2-..., CS -FH2-... CS-FH-..., CS-FH Interconnecting busbars CS-FH000-L. CS-FH000-L Adapters for busbar systems with spacing 60mm OD-FH000-AL60 OD-FH00-AL60 OD-FH-AL60 OD-FH2-AL60 OD-FH-AL60 - Assembly kits for 2-pole, 4-pole OD-FH000-SS24 OD-FH00-SS24 OD-FH2-SS24 - Connecting space covers OD-FH000-KPA OD-FH00-KP. OD-FH-KP. OD-FH2-KP. OD-FH-KP. - Barriers OD-FH000-Z. OD-FH00-Z OD-FH-Z OD-FH2-Z OD-FH-Z - Locking inserts OD-FH000-VU - OD-FH2-VU - Front shields OD-FH000-KR OD-FH00-KR OD-FH-KR OD-FH2-KR OD-FH-KR - C2

2 SUMMARY OF MODELS Description Connecting sets Barrier against accident contact Accessory for disconnector FH000 For connection of CU/AL conductor of cross-section To increase the safety of personnel in handling switch- Locking insert For locking the switch-disconnector cover. -disconnector. up to 95 mm2. Connecting space covers For additional covering of connecting space. Remote signalling of cover position Indicates closed state. Cable length m. For connection of Cu conductors/pole of cross-section 0 mm2. Adapter for busbar system with spacing 60 mm Busbar spacing 60 mm. Busbar thickness 5 2 mm. Busbar width 2 2 mm. Cable outlet bottom or top. Accessory for switch-disconnector FH00 For connection of Cu/Al conductor of cross-section up to 95 mm2. Accessory for switch-disconnector FH, FH2 and FH For connection of Cu/Al conductor of cross- -section up to 50 mm2 for FH and FH2, up to 00 mm2 for FH. Remote signalling of fuse-link state Enables remote signalling of fuse-link in fuse switch-disconnector. Assembly kit For assembling 2-pole or 4-pole. Interconnecting busbar Accessory for switch-disconnector FH000 and FH00. For connection from 2 up to 5 pcs. -pole switch- -disconnectors. Front shield Additional covering of free space around the fuse switch-disconnector. C

3 FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH are intended for fuse-links with blade contacts. Enable safe disconnection not only of rated current, but also overcurrent up to octuple rated current. Variability of connecting sets. Measuring holes in the cover. It is possible to lock the switch-disconnector cover. It is equipped with a label for description of the protected circuit. Mounting directly on the panel by means of screws. On busbars with spacing 60 mm by means of adapter. More switch-disconnectors side-by-side or flat can be installed without limitation of electrical parameters. FH connection with terminal screws M0/20 Nm for cable lugs max. 4 mm and busbars of width max. 25 mm. FH2 connection with terminal screws M0/20 Nm for cable lugs max. 40 mm and busbars of width max. 0 mm. FH connection with terminal screws M2/28 Nm for cable lugs max. 44 mm and busbars of width max. 40 mm. Connecting sets with terminal inbus screws. Connection Bottom connection is possible without limitation of electric parameters (the device should be marked ATTENTION, BOTTOM CONNECTION ). In [A] Number of poles FH-A/F FH-A/F FH2-A/F FH2-A/F FH-A/F FH-A/F Order code OEZ:462 OEZ:464 OEZ:469 OEZ:468 OEZ:474 OEZ:47 Weight [kg] Package [pcs] Weight [kg] Package [pcs] Weight [kg] Package [pcs] with remote signalling with cable Includes a connector with a m cable. In [A] Number of poles FH-S/F FH-S/F FH2-S/F FH2-S/F FH-S/F FH-S/F Order code OEZ:46 OEZ:465 OEZ:47 OEZ:470 OEZ:476 OEZ:475 with remote signalling without cable Includes a connector without cable. In [A] Number of poles FH-SB/F FH2-SB/F FH-SB/F with light indication By means of LED in each pole separately. In [A] Number of poles FH-L/F FH2-L/F FH-L/F Order code OEZ:467 OEZ:472 OEZ:477 The red LED is flashing in case of fuse-link blowing. Order code OEZ:20769 OEZ:20770 OEZ:2077 Weight [kg] Package [pcs] Accessories Connecting sets Adapters Assembly kit Locking insert Remote signalling of cover position Connecting space covers Front shield Barriers Spare parts C20 CS-.. OD-..-AL60 OD-FH2-SS24 OD-FH2-VU OD-FH-SK OD-..-KP. OD-..-KR OD-..-Z ND-.. page C27 page C0

4 FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH Specifications FH FH2 FH Standards IEC IEC IEC IEC IEC IEC EN EN EN EN EN EN Approval marks Rated operating current I e 250 A 400 A 60 A Rated operating voltage U e AC/DC 690 V AC/DC 690 V AC/DC 690 V (AC/DC 400 V / FH-L/.) (AC/DC 400 V / FH2-L/.) (AC/DC 400 V / FH-L/.) Utilization category ) FH.-./. AC 400 V AC-2B AC-2B AC-2B AC 500 V AC-22B AC-22B AC-22B AC 690 V AC-2B AC-22B AC-22B DC 250 V DC-2B DC-2B DC-2B DC 440V DC-2B / 60 A DC-2B / 250 A DC-2B / 5 A FH.-./. AC 400 V AC-2B AC-2B AC-2B AC 500 V AC-22B AC-2B AC-2B AC 690 V AC-22B AC-22B AC-22B two-pole connection DC 440 V DC-2B DC-2B DC-2B Rated thermal current with fuse-link I th 250 A 400 A 60 A Rated thermal current with disconnecting link I th 25 A 520 A 750 A ZP in FH, ZP2 in FH2, ZP in FH 000 A / ZP/000 Rated frequency f n Hz Hz Hz Rated insulation voltage U i AC 000 V AC 000 V AC 000 V Rated conditional short-circuit current (RMS) I cc AC 400 V 20 ka / 250 A 20 ka / 400 A 20 ka / 60 A AC 500 V 50 ka / 250 A 50 ka / 400 A 50 ka / 60 A AC 690 V 25 ka / 250 A 25 ka / 400 A 25 ka / 60 A Rated impulse withstand voltage U imp 2 kv / FH-.A/. 2 kv / FH2-.A/. 2 kv / FH-.A/. 8 kv / FH-.S/. 8 kv / FH2-.S/. 6 kv / FH-.S/. 2 kv / FH-L/. 2 kv / FH2-L/. 2 kv / FH-L/. Rated short-time withstand current I cw s 5 ka 5 ka 20 ka Fuse-link size 2 Max. power losses of the fuse-link P v 2 W 4 W 48 W Power losses at I n without fuse-link P z 9 W 2 W 49 W Overvoltage category for AC 690 V IV IV IV Connection Connecting screw M0 M0 M2 Torque 20 Nm 20 Nm 28 Nm Remote signalling Max. voltage/current U max /I max AC 250 V / 5 A AC 250 V / 5 A AC 250 V / 5 A DC 250 V / 0.2 A DC 250 V / 0.2 A DC 250 V / 0.2 A Light indication Rated voltage U n AC V AC V AC V DC V DC V DC V Fuse-link is blown red LED is blinking red LED is blinking red LED is blinking Operating conditions Electrical endurance operating cycles 200 at 250 A 200 at 400 A 200 at 60 A Mechanical endurance operating cycles Degree of protection from front side, built-in device, cover closed IP0 IP0 IP0 (without measuring holes broken off) Degree of protection from front side, built-in device, cover opened or removed IP20 IP20 IP20 Operating ambient temperature C C C Working position see page I see page I see page I Max. sea level m m m Pollution degree Seismic resistance according to VE ŠKODA Hz / g Hz / g Hz / g ) In case of use disconnecting links ZP in FH, ZP2 in FH2 and ZP in FH switch-disconnector, the utilization category is decreased by one degree C2

5 FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH Dimensions FH FH-A/F FH-A/F and FH-L/F * *** FH-A/F, FH-A/F and FH-L/F 24 OD-FH-KP. 67 * *** OD-FH-KP. 67 * for FH-A/F= 78 ** for FH-A/F= 6 *** for FH-A/F=27 5 ** FH OD-FH-AL60 FH-S/F and FH-S/F * for FH-S/F= 78 ** for FH-S/F= 6 *** for FH-S/F= 8 5 ** C22

6 FUSE SWITCH-DISCONNECTORS FH, FH2, FH Dimensions FH2 FH2-A/F FH, FH2, FH FH2-A/F and FH2-L/F FH OD-FH2-AL o * 4 *** FH2-, FH2-A/F OD-FH-KP. 8 FH2-A/F and FH2-L/F * for FH2-A/F= 78 ** for FH2-A/F= 50 *** for FH2-A/F= * *** 8 OD-FH-KP ** FH2-S/F and FH2-S/F * for FH2-S/F= 78 ** for FH2-S/F= 50 *** for FH2-S/F= ** C2

7 FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH Dimensions FH FH-A/F FH-A/F and FH-L/F FH-A/F, FH-A/F and FH-L/F OD-FH-KP * * for FH-A/F= 78 ** for FH-A/F= 58 *** for FH-A/F= *** 95 OD-FH-KP. 59 ** FH OD-FH-AL60 FH-S/F and FH-S/F * * for FH-S/F= 78 ** for FH-S/F= 58 *** for FH-S/F=49 45*** ** C24

8 FUSE SWITCH-DISCONNECTORS FH, FH2, FH Dimensions FH, FH2, FH Clearance and drilling diagrams FH -pole 7 2-pole pole, 4-pole FH2 -pole 79 2-pole pole, 4-pole FH -pole 2-pole -pole, 4-pole C25

9 FH, FH2, FH FUSE SWITCH-DISCONNECTORS FH, FH2, FH Diagram FH-.. FH2-.. FH-.. 2x FH-.. 2x FH2-.. 2x FH-.. 2x FH-.. 2x FH2-.. 2x FH-.. FH-.. FH2-.. FH-.. FH-.. + FH-.. FH FH2-.. FH-.. + FH-.. FH-.. + FH-.. FH FH2-.. FH-.. + FH pole connection of -pole fuse switch-disconnector for DC application, see Utilization category + -pole connection of two -pole fuse switch-disconnectors for DC applications, see Utilization category Remote signalling of fuse state in -pole fuse switch-disconnector State of contacts with not blown fuse: contacts closed Remote signalling of fuse state in -pole fuse switch-disconnector State of contacts with not blown fuse: contacts 7, 2 8, - 9 closed Remote signalling of cover position of -pole and -pole switch-disconnectors State of contacts with open cover: contacts C NC closed (yellow) (blue) (white) C26

10 FH, FH2, FH ACCESSORIES FOR FH, FH2, FH For FH, FH2 Connecting sets up to 6 mm 2 Torque 4,5 Nm. Order Description Cross-section Weight Package CS-FH2-SM OEZ:584 clip terminal, pcs Cu 6 6 mm CS-FH2-SM OEZ:585 clip terminal, pcs Cu 6 6 mm Connecting sets up to 50 mm 2 Torque 4,5 Nm. Order Description Cross-section Weight Package CS-FH2-S OEZ:559 clip terminal, pcs Cu mm CS-FH2-S OEZ:8226 clip terminal, pcs Cu mm CS-FH2-P OEZ:5592 prismatic clamp, pcs Cu/Al mm 2 0. CS-FH2-P OEZ:8227 prismatic clamp, pcs Cu/Al mm Double prismatic looping sets Torque 4,5 Nm. Order Description Cross-section Weight Package CS-FH2-P2 OEZ:559 pcs Cu/Al 2x (70 95) mm CS-FH2-P2 OEZ:8228 pcs Cu/Al 2x (70 95) mm For FH2 Connecting sets up to 240 mm 2 Torque 0 Nm. Order Description Cross-section Weight Package CS-FH2-S OEZ:5595 clip terminal, pcs Cu mm CS-FH2-S OEZ:58 clip terminal, pcs Cu mm CS-FH2-P OEZ:5595 prismatic clamp, pcs Cu/Al mm CS-FH2-P OEZ:58 prismatic clamp, pcs Cu/Al mm Double prismatic looping sets Torque 4,5 Nm. Order Description Cross-section Weight Package CS-FH2-P2 OEZ:5597 pcs Cu/Al 2x (20 50) mm CS-FH2-P2 OEZ:58 pcs Cu/Al 2x (20 50) mm C27

11 FH, FH2, FH ACCESSORIES FOR FH, FH2, FH For FH Connecting sets up to 00 mm 2 Torque 0 Nm. Order Description Cross-section Weight Package CS-FH-P OEZ:5800 clip terminal, pcs Cu/Al mm CS-FH-P OEZ:484 clip terminal, pcs Cu/Al mm Double prismatic looping sets Torque 0 Nm. Order Description Cross-section Weight Package CS-FH-P2 OEZ:580 pcs Cu/Al 2x (20 240) mm CS-FH-P2 OEZ:485 pcs Cu/Al 2x (20 240) mm For FH, FH2 and FH Terminals for rear connection Torque 20 Nm. Order Description Weight Package CS-FH2-Z OEZ:5594 pcs 0.7 CS-FH2-Z OEZ:8229 pcs C28

12 FH, FH2, FH ACCESSORIES FOR FH, FH2, FH Adapters for busbar systems Busbar spacing 60 mm. Cable outlet bottom or top. Busbar thickness 5 2 mm. Busbar width 2 2 mm. Order Accessory for Weight Package OD-FH-AL60 OEZ:7270 FH OD-FH2-AL60 OEZ:482 FH OD-FH-AL60 OEZ:9557 FH Assembly kit For assembling 2-pole or 4-pole. 2-pole unit is assembled by means of two FH pole unit is assembled by means of one FH.-... and one FH.-... Order Accessory for Weight Package OD-FH2-SS24 OEZ:7266 FH, 2, Locking insert For locking the switch-disconnector cover. Max. diameter of the padlock suspension loop is 4.5 mm. The padlock is not included in the delivery. Order Accessory for Weight Package OD-FH2-VU OEZ:820 FH, 2, Remote signalling of cover position Indicates closed state. Cable length m. Possibility of mounting up to 2 microswitches per one switch-disconnector. Order Accessory for Weight Package OD-FH-SK OEZ:2929 FH, 2, 0.0 Technical information see page C26 Connecting space covers for adapter Identical for both upper and lower space. For additional covering of connecting space. Order Accessory for Weight Package OD-FH-KP OEZ:7269 FH OD-FH-KP OEZ:7268 FH OD-FH2-KP OEZ:48 FH OD-FH2-KP OEZ:480 FH OD-FH-KP OEZ:488 FH OD-FH-KP OEZ:487 FH Front shields Additional covering of free space around the fuse switch-disconnector. Order Accessory for Weight Package OD-FH-KR OEZ:7267 FH OD-FH2-KR OEZ:479 FH OD-FH-KR OEZ:486 FH Barriers against accident contact Increase the safety of personnel in handling fuse-links. Order Accessory for Weight Package OD-FH-Z OEZ:727 FH OD-FH2-Z OEZ:48 FH OD-FH-Z OEZ:490 FH C29

13 FH, FH2, FH ACCESSORIES FOR FH, FH2, FH Spare parts For FH Description Order Weight Package Cover without signalling of fuse state, -pole, size ND-FH-V OEZ: Cover without signalling of fuse state, -pole, size ND-FH-V OEZ: Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH-VS OEZ: Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH-VS OEZ: Cover with light indication of fuse state, -pole ND-FH-VL OEZ: For FH2 Description Order Weight Package Cover without signalling of fuse state, -pole, size 2 ND-FH2-V OEZ: Cover without signalling of fuse state, -pole, size 2 ND-FH2-V OEZ: Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH2-VS OEZ: Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH2-VS OEZ: Cover with light indication of fuse state, -pole ND-FH2-VL OEZ: For FH Description Order Weight Package Cover without signalling of fuse state, -pole, size 2 ND-FH-V OEZ: Cover without signalling of fuse state, -pole, size 2 ND-FH-V OEZ: Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH-VS OEZ: Cover with signalling of fuse state, -pole, includes a cable with connector ND-FH-VS OEZ: Cover with light indication of fuse state, -pole ND-FH-VL OEZ:5.008 For FH, FH2, FH Description Connector for -pole switch-disconnector with remote signalling of fuse state, without cable, with pins Connector for -pole switch-disconnector with remote signalling of fuse state, with -core cable Connector for -pole switch-disconnector with remote signalling of fuse state, without cable, with 9 pins Connector for -pole switch-disconnector with remote signalling of fuse state, with 9-core cable Order code Weight [kg] Package [pcs] ND-FH-SZ0 OEZ: ND-FH-SZ OEZ: ND-FH-SZ0 OEZ: ND-FH-SZ9 OEZ: C0

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K Varius SUMMARY OF MODELS OF FUSE-RAILS Type FSR00 FSR1 FSR2 FSR3 Rated operating current I e 160 A 250 A 400 A 630 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V Size 00 1 2 3 Busbar spacing

More information

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50 SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS Type SPB SPB SPF SP4.. SP50 Rated current I n 60 A / 0 A / 400 A 60 A / 0 A / 400 A 60 A / 0 A / 400 A / / 60 A Rated voltage AC/DC U n 690 V 690 V 690 V

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Overcurrent releases - description, specifications, characteristics specifications specifications description... BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE-10B-1N-030AC The device is a combination of residual current circuit breaker and circuit breaker.

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S MOULDED CASE CIRCUIT BREAKERS BH6N, BH6S F BH6N, BH6S COMMERCIAL INFORMATION Switching units, withdrawable device, plug-in device...f4 Switch-disconnector unit...f6 Connecting sets...f7 Mounting sets...f9

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

Devices for switching and control

Devices for switching and control Devices for switching and control WWWOEZCOM Motor starters MOTOR STARTERS SM Basic function Switching and protection of motors up to 2 A Protection against short-circuit and protection against overload

More information

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S H MOULDED CASE CIRCUIT BREAKERS BL6S H BL6S COMMERCIAL INFORMATION Switching units, withdrawable device...h4 Overcurrent releases...h5 Signalling units...h5 Residual current monitor...h6 Current transformers

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC6N Tento výrobek byl vyvinut za finanční podpory ze státních fondů prostřednictvím Ministerstva průmyslu a obchodu. D BC6N COMMERCIAL INFORMATION Circuit breakers...d4

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

Horizontal fuse disconnects

Horizontal fuse disconnects THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka) Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE ( ka) The device is a combination of residual current circuit breaker and circuit breaker For

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

MULTIVERT 250A Size 1, 690VAC

MULTIVERT 250A Size 1, 690VAC MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.

More information

MOULDED CASE CIRCUIT BREAKERS BL1600S

MOULDED CASE CIRCUIT BREAKERS BL1600S H MOULDED CASE CIRCUIT BREAKERS BL6S H BL6S COMMERCIAL INFORMATION Switching units, withdrawable device, plug-in device...h4 Overcurrent releases...h Signalling units...h Connecting sets...h6 Switches...H8

More information

LV HRC fuse switch-disconnectors

LV HRC fuse switch-disconnectors The 9 series LV HRC fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different sizes are available as 1-pole,

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka) Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) Standard type for common use in building and housing installations up to 3 A, 230/400 V a.c. They react to alternating sine-wave

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka) Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka) They react to both alternating sine-wave residual current and pulsating direct current (type A) For protection: against accidental

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

Residual current circuit breakers with conditional shortcircuit

Residual current circuit breakers with conditional shortcircuit LFE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS LFE Residual current circuit breakers with conditional shortcircuit current 6 ka. They react to sine-wave residual current (type

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

IP20 degree of protection; IP40 degree of protection after installation in a distribution box RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance

More information

switch disconnectors switch disconnectors fuses

switch disconnectors switch disconnectors fuses SWITCHGER R switch disconnectors RB switch disconnectors fuses R switch disconnectors and RB switch disconnectors fuses are designed for distribution of electricity, making and breaking currents and protection

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric

More information

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC FUSE RAILS IEC NH FUSE RAILS FEATURES & BENEFITS Installation on to Dimensions of s and cable connections are equivalent to those of MULTIVERT APPLICATIONS

More information

Switch-disconnectors OT , OETL 3150

Switch-disconnectors OT , OETL 3150 Switch-disconnectors OT 16...2500, OETL 3150 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 Front operated switch-disconnectors OT, OETL 24 Side operated

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Euroload Changeover Switch

Euroload Changeover Switch Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products 94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation

More information

MULTIVERT 1000A Main Incomer, 690VAC

MULTIVERT 1000A Main Incomer, 690VAC IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed

More information

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Breakers and Switches. Switches Switch-disconnectors OT and OTM Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

Selective main circuit breakers S 750 series Technical Data

Selective main circuit breakers S 750 series Technical Data Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.

More information

LINOCUR Size D02 63A 230VAC/440VAC

LINOCUR Size D02 63A 230VAC/440VAC IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated

More information

Crimpmate Range pitch 5.00

Crimpmate Range pitch 5.00 Contents pitch. pitch. pitch. Male and female connectors with solder connection. Male and female connectors with crimp connection. Crimp contacts..1 pitch. RSV 1. S Derating curve RSV1. S SN Rectangular

More information

Breakers and Switches. Switches Change-over and transfer switches

Breakers and Switches. Switches Change-over and transfer switches Breakers and Switches Switches Change-over and transfer switches Change-over and transfer switches 16...2500 A Contents: 4 Product overview, features 8 Technical data 8 Manual, motorized and automatic

More information

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed

More information

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors Fuse monitoring possible throughout Busbar supports can be

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

Vertical fuse disconnects

Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric circuits under

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

25A 25A 32A 40A 40A 63A 63A 80A

25A 25A 32A 40A 40A 63A 63A 80A ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems The Complete Range Easy mounting onto supporting rails Protection against accidental contact in the standart version Perforated versions for connections Drawing of the NH Fuse-Switch, 3-pole switching,

More information

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W SCHRACK-INFO Lift and clamp terminals on both sides Terminal guide for secure connection Terminal cross-section: 1-25mm² Snap-on mounting for

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Range / Produktpalette Type 415 fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

NH-Fuse system Low voltage

NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

Switches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION:

Switches. Fused Switches ITCP for Semiconductor Fuses 32 to 800A CONTROL: FUSE CONNECTING: SWITCHING: MECHANISM: FIXING: CONSTRUCTION: Fused CONTROL: Side control, padlockable in off position by three padlocks. Safe and reliable of contact position on handles. SWITCHING: Double isolation per phase. Complete isolation of fuse when circuit

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse

More information

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise PROTECTION AND CONNECTION ABB Compact ATS Compact without compromise 2 A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E ABB ARTICLE COMPACT OR CHAPTER ATS COMPACT TITLE WITHOUT COMPROMISE

More information

Low Voltage Switches. Switches Motorized change-over switches OTM _C

Low Voltage Switches. Switches Motorized change-over switches OTM _C Low Voltage Switches Switches Motorized change-over switches OTM...12_C II I OTM 12_C Improves your permance OTM II I 0 OFF ON I 0 OFF II I ON I ssembly made easy Bridging bars quick wiring Tunnel terminals

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Miniature circuit-breaker (MCB) SH200M Series

Miniature circuit-breaker (MCB) SH200M Series Miniature circuit-breaker (MCB) SH200M Series 25 mm² cage terminals, a well proven and reliable technology. IP20 - finger safety. Scratch and solvent resistant marking due to laser printing. Easy identification

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information