Motorized switch-disconnectors OTM 40 to 125 Amperes
|
|
- Dominick Garrett
- 6 years ago
- Views:
Transcription
1 Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM are a good solution for different applications. OTM optimizes installation time and use of space and have a high performance. Easy installation Tunnel terminals ensure a tight and good connection. With the snap-on accessories, no extra tools are needed. The switch can be mounted in any direction. Fast and reliable installation always High performance The motor operator has a wide operation voltage range. Tested according to IEC OTM is suitable for many applications Safe to use OTM provides isolation, ensuring a safe maintenance work. ll-time reliable position indication Finger-safe construction that prevents contact with live parts. Mechanical and electrical locking options available. Safe and reliable operation compact solution OTM has a very small footprint, which minimizes the need for space. Reduced space means cost savings
2 Technical data OTM Motorized switch-disconnectors Data according to IEC Switch size Rated insulation voltage and rated operational voltage C20/DC20 Pollution degree 3 V Dielectric strength 50 Hz 1min. kv Rated impulse withstand voltage kv Rated thermal current and rated operational current C20/DC20 / ambient C In open air / ambient C In enclosure / ambient C In enclosure..with minimum conductor cross section Cu mm 2 Rated operational current, C-21 up to 500 V 690 V Rated operational current, C-22 up to 500 V 690 V Rated operational current, C-23 up to 415 V 500 V 690 V Rated operational current / poles in series, DC-21 Rated operational current / poles in series, DC-22 Rated operational current / poles in series, DC-23 up to 48 V 1 V 220 V up to 48 V 1 V 220 V up to 48 V 1 V 220 V 230 V 0 V Rated operational power, C-23 1) The kw-ratings are accurate for 3-phase 1500 R.P.M. standard asychronous motors 415 V kw 500 V kw 690 V kw Rated breaking capacity in category C-23 up to 415 V 500 V 690 V î c (peak) gg/am î c (peak) gg î c (peak) gg/am Rated conditional short-circuit current I p (r.m.s.) and corresponding max. allowed cut-off current î c (peak) value. The cut-off current î c refers to values listed by fuse manufacturers (single phase test acc. to IEC269). I p (r.m.s.) 50 k, 415 V Max. OF_ fuse size I p (r.m.s.) 18 k, 690 V Max. OF_ fuse size I p (r.m.s.) 50 k, 690 V Max. OF_ fuse size Rated short-time withstand current I cw (r.m.s.) 690 V 1s k Rated short-time making capacity 2) I cm (peak) 690 V k Power loss / pole With rated current W Mechanical endurance Number of oper. cycles 3) Cycles Mechanical endurance / switch Number of operations Oper. Cable size Cu-wire size suitable mm 2 for terminal clamps WG Terminal tightening torque Counter torque required Nm Operating torque Typical for 3-pole switches Nm Weight without accessories 3-pole switch kg 4-pole switch kg 1) These values are given for guidance and may vary acc. to the motor manufacturer. 2) Short circuit duration >50ms, without fuse protection 3) Operating cycle: O - I - O kw kw k / k k / 2 1SCC3011B0201 OTM...125
3 OTM_ OTM63_ OTM80_ OTM0_ OTM125_ /1 /2 /4 /1 /2 /4 /1 /2 / /1 63/2 63/1 63/2 63/1 63/ /1 80/2 80/1 80/2 80/1 80/ /1 0/2 0/4 0/1 0/2 0/1 0/ /1 125/2 0/4 125/1 125/2 125/1 125/ /2x /2x OTM SCC3011B0201 3
4 Technical data, motor operator OTM Data for motor operator according to IEC 947 Switch size 125 Rated operational voltage U e Pollution degree 3 50/ Hz V C/DC V DC Operating voltage range x U e Operating time 1) 90 I-0, 0-I V C/DC 24 V DC s s Operating rate Cycle 0-I-0 Max. continuous Max. short-time cycles cycles/min cycles/min 1 Overvoltage category Rated impulse withstand voltage Uimp Dielectric strength Impulse command kv kv III Hz 1 min. Min. impulse duration ms 0 Terminals Voltage supply wiring for U e Cross section Solid/stranded mm 2 PE - N - L Short-circuit protection device Max. MCB 16 Control terminal for the push -buttons C - I - O Cross section Solid/stranded mm Maximum cable length m 0 Terminal for state information lso used with the OMD automatic control unit Solid/stranded Rating mm C-1/250V Common, voltage supply 11 Handle attached or motor operator locked 14 Short-circuit protection device Max. MCB C2 Operating temperature Transportation and storage temperature C C Max. altitude m Protection degree (front panel) IP20 Motor operator, control unit Value Cabling/Rating Control terminal for the push-buttons C 1,5-2mm 2 Maximum cable length 0m 1) Under nominal conditions OTM SCC3011B0201 4
5 11 14 PE N L C I Fuse Reset Ordering information OTM...125F3M_ OTM...125F4M_ S073 Delivery Weight/ batch unit Type Order code [pcs] [kg] OTMF3M230V 1SC122972R01 1 1,13 OTM63F3M230V 1SC122971R01 1 1,13 OTM80F3M230V 1SC122970R01 1 1,13 OTM0F3M230V 1SC122969R01 1 1,13 OTM125F3M230V 1SC122968R01 1 1,13 OTMF4M230V 1SC122977R01 1 1,24 OTM63F4M230V 1SC122976R01 1 1,24 OTM80F4M230V 1SC122975R01 1 1,24 OTM0F4M230V 1SC122974R01 1 1,24 OTM125F4M230V 1SC122973R01 1 1,24 Dimension drawings 52 Ø4,5 22,5 26 EN OTM ,5 6, , ( 3-pole ) 186,5 ( 4-pole ) M00353/OTM30-125F_M B OTM SCC3011B0201 5
6 OTM30GB 13-01, 1SCC3011B0201 For more information please contact: BB Oy Breakers and Switches P.O. Box 622 FI-651 Vaasa, Finland Phone: Fax:
Low Voltage Switches. Switches Motorized change-over switches OTM _C
Low Voltage Switches Switches Motorized change-over switches OTM...12_C II I OTM 12_C Improves your permance OTM II I 0 OFF ON I 0 OFF II I ON I ssembly made easy Bridging bars quick wiring Tunnel terminals
More informationProtection and Connection Motorized and automatic transfer switches IEC Technical guide
Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety
More informationPROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise
PROTECTION AND CONNECTION ABB Compact ATS Compact without compromise 2 A B B C O M PA C T AT S C O M PA C T W I T H O U T C O M P R O M I S E ABB ARTICLE COMPACT OR CHAPTER ATS COMPACT TITLE WITHOUT COMPROMISE
More informationBreakers and Switches. Switches Change-over and transfer switches
Breakers and Switches Switches Change-over and transfer switches Change-over and transfer switches 16...2500 A Contents: 4 Product overview, features 8 Technical data 8 Manual, motorized and automatic
More informationBreakers and Switches. Switches Switch-disconnectors OT and OTM
Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,
More informationSwitches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes
Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes OTDC16...32U - Compact efficiency OTDC from 16 to 32 amperes offers various DC voltage ratings and a control
More informationSwitch-disconnectors OT , OETL 3150
Switch-disconnectors OT 16...2500, OETL 3150 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 Front operated switch-disconnectors OT, OETL 24 Side operated
More informationLow Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201
Low Voltage Products SwitchLine OT change-over switches 160, 200, 0, 315, 400, 630 and 800 mps Catalogue OT7G 05_09 1SCC301012C0201 Ith / Ie /C22, 415V Ie /C23, 415V OT160E OT160E_W OT200E OT200E_W OT0E
More informationEnclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes
Protection and Connection Enclosed DC rated switchdisconnectors OTDCP from 16 to 32 Amperes Enclosed OTDC switches from 16 to 32 Amperes meet the demanding requirements of photovoltaic applications. Enclosed
More informationSystem pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489
Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationLow Voltage Switches. Switches Switch fuses OS A Gamma series
Low Voltage Switches Switches Switch fuses OS32...1 Gaa series Switch fuses for extreme conditions - OS 32 1 Gaa series Numerous applications require switch fuses that can withstand extreme conditions.
More informationLow Voltage Switches. Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM
Low Voltage Switches Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM Motorized switches OTM 60...2500, OSM 2...250 Contents Product overview 6 Features 8 Technical data 6
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationFuse switch-disconnectors
Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationMS25, MST25, MS20, MST20
Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More informationFuse switch-disconnectors
Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version
More informationLow Voltage Switches. Fusegear Switch fuses OS and OSM
Low Voltage Switches Fusegear Switch fuses OS and OSM Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 DIN-
More informationL O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR
L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR The safest way to switch power on and off in your industrial control panels. Your problem: You
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationK30H001YP cam star-delta switch - 3-pole A - screw mounting
Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationLow Voltage Products. Switches Switch-disconnectors OT and OETL
Low Voltage Products Switches Switch-disconnectors OT and OETL Switch-disconnector IEC lth /A le /AC22A, 415V le /AC23A, 415V... OT16F OT63F OT100F OT160E OT25F OT80F OT125F OT40F 25 32 40 63 80 115 125
More informationSwitches for photovoltaic applications Switch-disconnectors OTDC and OTDCP
Contact us ABB Oy Breakers and Switches P.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 10 22 11 Fax: +358 10 22 45708 E-Mail: firstname.surname@fi.abb.com www.abb.com The technical data and dimensions
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationVarius SUMMARY OF MODELS
SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V
More informationElectronic overload relays EF205 and EF370
Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationTechnical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products
94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation
More informationSystem pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077
Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with
More informationVarius SUMMARY OF MODELS
SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationScheda prodotto Relè Series E
Relè Miniatura All-or-Nothing relays ideally suited for any electronic appliances demanding very compact design and low power consumption. Design includes a protective dust cover and a completete range
More informationVarius SUMMARY OF MODELS
Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationCylindrical fuse-link
Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH
More informationCOMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33
BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationThermal overload relay TF140DU and TF140DU-V1000
Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against
More informationDCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More informationMANUALLY OPERATED CHANGEOVER SWITCHES
are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,
More informationManual motor starter MS132
Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More information25A 25A 32A 40A 40A 63A 63A 80A
ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A
More informationSiemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage
SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationUL 508 Non-Fusible Disconnect Switches
UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationBrocure panorama. Switches for photovoltaic applications Disconnect switches OTDC and OTDCP
Brocure panorama Switches for photovoltaic applications Disconnect switches OTDC and OTDCP DC switch-disconnectors, front operated 16...800 A, IEC IEC 60947 OTDC16F2 OTDC16F3 OTDC16F4 OTDC100E02 OTDC100E11
More informationBreakers and Switches. Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP
Breakers and Switches Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Switch-disconnectors OTDC16...250, OT315...630 and OTDCP16...32 Contents 4 Product overview 8 Technical data
More informationLow Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201
Low Voltage Products Enclosed switches Brochure OT_KSE 1 GB 05_02 O I N O SafeLine OF F 2 I Enclosed switches Contents: General... 4 Technical data... 5 Switches in plastic enclosure General... 6 Ordering
More informationIEC Low Voltage General Purpose Protection
, 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6
More informationLOAD BREAK SWITCHES. Ensto Compact
LOAD BREAK SWITCHES Ensto Compact Ensto Enclosures and Components Ensto also offers enclosed switches; being assemblies of Ensto Cubo enclosures and load break switches. Ensto is an international industrial
More informationUL 508 Non-Fusible Disconnect Switches
UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.
More informationEuroload Changeover Switch
Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More information500V / V /
LOAD BREAK SWITCHES 125-630 A TECHNICAL DATA ATEX RoHS Compliant 2002/95/EC LOAD BREAK SWITCHES 16A 25A 40A 63A 80A 125A 160A KU / KU / KU / KU / KU / KU / VKA / VKA / KUE KUE KUE KUE KUE KUE EVA EVA VKA
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection
More informationVB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated
VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationManual motor starter MS132
Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationChangeover & Bypass Sw it ches
Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without
More informationOvercurrent releases - description, specifications, characteristics specifications specifications description...
BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting
More informationManual motor starter MS132
Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationMULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole
MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More information55 Series - Miniature General Purpose Relays 5-10 A
Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:
More informationSwitch fuses OS , OSM
Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 16 Ordering information, manual operation 16 Front operated switch fuses OS 25 Side operated switch fuses
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationApproved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated
More informationSwitch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV
Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads
More informationNSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals
NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationMiniature circuit-breaker (MCB) SH200M Series
Miniature circuit-breaker (MCB) SH200M Series 25 mm² cage terminals, a well proven and reliable technology. IP20 - finger safety. Scratch and solvent resistant marking due to laser printing. Easy identification
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationA Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.
C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,
More informationFuse switch disconnectors
SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED
More informationManual motor starter magnetic only MO325
Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF
More informationTechnical Data Accessories MCBs Ex9B.
Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationMini contactors B6, BC6 with 3 pole
Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More informationCat N 3. OVERALL DIMENSIONS
Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationThermal overload relay TF65 and TF96
Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationFL series position switches
FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationMULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole
MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More information