MOULDED CASE CIRCUIT BREAKERS BL1600S

Size: px
Start display at page:

Download "MOULDED CASE CIRCUIT BREAKERS BL1600S"

Transcription

1 H MOULDED CASE CIRCUIT BREAKERS BL6S H

2 BL6S COMMERCIAL INFORMATION Switching units, withdrawable device, plug-in device...h4 Overcurrent releases...h Signalling units...h Connecting sets...h6 Switches...H8 Shunt trips...h8 Undervoltage releases...h8 Hand drives...h9 Mechanical interlocking...h9 Motor drives...h9 Accessories...H Purchase order example...h Custom assembly of circuit breakers...h TECHNICAL INFORMATION Circuit breakers, switch-disconnectors - specifications...h - wiring diagram...h - connecting, installation...h4 - deionization space...h7 - dimensions...h8 Withdrawable device - description, specifications, wiring diagram...h Overcurrent releases General information...h DTV - distribution - description, specifications, tripping characteristics...h4 MTV8 - motor - description, specifications, tripping characteristics...h U - universal - description, specifications, tripping characteristics...h7 Signalling units Connecting sets Switches Shunt trips - description, specifications, wiring diagram...h4 - specifications...h4 - specifications, wiring diagram...h4 - specifications, wiring diagram...h4 Undervoltage releases - specifications, wiring diagram...h4 Hand drives - description, specifications...h44 Mechanical interlocking - description, specifications, dimensions...h4 Motor drives - description, specifications, wiring diagram...h47 H

3 BL6S SUMMARY OF MODELS AND ACCESSORIES CONNECTING SETS Clamp type terminals Clamp type terminals Block type terminals Block type terminals Block type terminals Rear connection Front connection Rear connection CS-BL-W CS-BL-W CS-BL-B CS-BL-B CS-BL-B4 CS-BL-A CS-BL-A CS-BL-A HAND DRIVES RP-BL-CK RP-BL-CP SWITCHING UNIT BL6SE SWITCHING UNIT - WITHDRAWABLE DESIGN BL6SE WITHDRAWABLE DEVICE ZV-BL-6- RP-BL-CH RP-BL-CN Mechanical interlocking RL-BL-CB Mechanical interlocking by Bowden MB-BL-... MOTOR DRIVES MP-BL-X SWITCHES PS-BL- Position signalling SO-BL- SHUNT TRIP OVERCURRENT RELEASES SWITCH-DISCONNECTOR UNIT SIGNALLING UNITS SV-BL-X UNDERVOLTAGE RELEASE SP-BL-X SE-BL-...-DTV SE-BL-...-MTV8 SE-BL-6-V SB-BL- SE-BL-...-U ACCESSORIES Locking-type lever Sealing inset Extension cable Terminal cover Terminal cover OD-BL-UP OD-BL-VP OD-BL-KA OD-BL-KS OD-BL-KS4 Insulating barriers Insulating barriers Insulating grommets Mounting bolts OD-BL-KS OD-BL-KS8 OD-BL-KS OD-BL-MS H

4 BL6S - Commercial information SWITCHING UNITS Fixed design Type Product code I u [A] I cu [ka] Weight [kg] Packing [pc] BL6SE TECHNICAL INFORMATION, see page H - the way of power circuit connection must respect our recommendations, see page H4 as well as deionization space, see page H7 - Switching unit: includes - insulating barriers OD-BL-KS - set of installation bolts OD-BL-MS (4x M8x8) - connecting sets for front connection - busbars connection must be fitted with - overcurrent release SE-BL-J (circuit breaker) or switch-disconnector unit SE-BL-J6-V (switch-disconnector) Withdrawable design Type Product code I u [A] I cu [ka] Weight [kg] Packing [pc] BL6SE TECHNICAL INFORMATION, see page H - Switching unit must be fitted with - overcurrent release SE-BL-J (circuit breaker) or switch-disconnector unit SE-BL-J6-V (switch-disconnector) - Withdrawable device ZV-BL-6- WITHDRAWABLE DEVICE Type Product code Name Weight [kg] Packing [pc] ZV-BL-6- Withdrawable device 4. - TECHNICAL INFORMATION, see page H - the way of power circuit connection must respect our recommendations, see page H4 as well as deionization space, see page H7 - Withdrawable device: must be fitted with - x connection sets CS-BL-A (front connection) or CS-BL-A (rear connection) We recommend fitting with - mounting bolts set OD-BL-MS (4 x M8x6) H4

5 BL6S - Commercial information OVERCURRENT RELEASES DTV - characteristic D - distribution protecting lines and transformers I n [A] Type Product code Description Weight [kg] Packing [pc] 6 SE-BL-6-DTV 7 Regulation I r = 6 A. SE-BL--DTV 8 Regulation I r = 4 A. SE-BL--DTV 988 Regulation I r = A. 6 SE-BL-6-DTV 9 Regulation I r = 6 6 A. - TECHNICAL INFORMATION, see page H4 MTV8 - characteristic M - motor direct protection for motors and generators suitable also for protecting lines and transformers I n [A] Type Product code Description Weight [kg] Packing [pc] 6 SE-BL-6-MTV8 7 Regulation I r = 6 A. SE-BL--MTV8 8 Regulation I r = 4 A. SE-BL--MTV8 989 Regulation I r = A. 6 SE-BL-6-MTV8 9 Regulation I r = 6 6 A. - TECHNICAL INFORMATION, see page H U - characteristic U - universal protecting complicated loads or those not specified in advance I n [A] Type Product code Description Weight [kg] Packing [pc] 6 SE-BL-6-U Regulation I r = 6 A.9 SE-BL--U 64 Regulation I r = 4 A.9 SE-BL--U Regulation I r = A.9 6 SE-BL-6-U 6 Regulation I r = 6 6 A.9 - TECHNICAL INFORMATION, see page H7 SWITCH-DISCONNECTOR UNIT I e [A] Type Product code Name Weight [kg] Packing [pc] 6 SE-BL-6-V 4 Switch-disconnector unit.4 - TECHNICAL INFORMATION, see page H SIGNALLING UNIT Type Product code Description Weight [kg] Packing [pc] SB-BL for overcurrent releases DTV, DTV8 and U - TECHNICAL INFORMATION, see page H4.67 H

6 BLS, BL6S - Commercial information CONNECTING SETS Type Product code Description S [mm ] Connection Weight [kg] Packing [set] ) CS-BL-W 7 Clamp type terminals - double x 7 4 Cu/Al cables.47 - TECHNICAL INFORMATION, see page H - For connecting four 7 4 mm cables to pole, it is possible to use two CS-BL-W connecting sets (see page H9). Not for BLSE switching unit. CS-BL-W 9 Clamp type terminals 7 4 Cu/Al cables.66 - TECHNICAL INFORMATION, see page H - For connecting three 7 4 mm cables to pole it is possible to combine CS-BL-W connecting set with CS-BL-W connecting set (see page H6, H9). Not for BLSE switching unit. CS-BL-A 6 Rear connection - up to A Busbars.4 - TECHNICAL INFORMATION, see page H CS-BL-A 6 Rear connection - up to 6 A Busbars.76 - TECHNICAL INFORMATION, see page H CS-BL-A Front connection of withdrawable design - TECHNICAL INFORMATION, see page H Busbars.7 CS-BL-A 7 Rear connection of withdrawable design - TECHNICAL INFORMATION, see page H Busbars.4 ) - One set provides for connecting one side of the circuit breaker (set includes three terminals with necessary coupling elements). H6

7 BLS, BL6S - Commercial information CONNECTING SETS Type Product code Description S [mm ] Connection Weight [kg] Packing [set] ) CS-BL-B 6 Block type terminal - for cables - TECHNICAL INFORMATION, see page H Cu/Al cables. CS-BL-B 7 Block type terminal - for cables - TECHNICAL INFORMATION, see page H Cu/Al cables. CS-BL-B4 8 Block type terminal - for 4 cables - TECHNICAL INFORMATION, see page H Cu/Al cables.8 ) - One set provides for connecting one side of the circuit breaker (set includes three terminals with necessary coupling elements.) H7

8 BLS, BL6S - Commercial information AUXILIARY SWITCHES Type Product code Operational voltage Contacts Weight [kg] Packing [pc] PS-BL- 6 V a.c./6 4 V d.c..4 PS-BL--Au 88 6 V a.c./d.c..4 - TECHNICAL INFORMATION, see page H4 SHUNT TRIPS UNDERVOLTAGE RELEASES Type Product code Operational voltage Weight [kg] Packing [pc] SV-BL-X V a.c/d.c.. SV-BL-X V a.c/d.c.. SV-BL-X 66 V a.c/d.c.. SV-BL-X 69 V a.c./ V d.c.. SV-BL-X V a.c.. SV-BL-X 67 V a.c.. - TECHNICAL INFORMATION, see page H4 Type Product code Operational voltage Weight [kg] Packing [pc] SP-BL-X V a.c/d.c.. SP-BL-X V a.c/d.c.. SP-BL-X 666 V a.c/d.c.. SP-BL-X 66 V a.c./ V d.c.. SP-BL-X V a.c.. SP-BL-X 66 V a.c.. - TECHNICAL INFORMATION, see page H4 H8

9 BLS, BL6S - Commercial information HAND DRIVES Type Product code Name - description Weight [kg] Packing [pc] RP-BL-CK 8 Hand drive unit - lockable. - TECHNICAL INFORMATION, see page H44 Hand drive unit is necessary to be completed: for controlling using the switch unit - with the black hand drive lever RP-BL-CP for controlling through the switchgear door - with the extension shaft RP-BL-CH - with the hand drive bearing RRP-BL-CN.. - with the hand drive lever RP-BL-CP.. Up to hand drive units can be ordered with the same lock. RP-BL-CP 86 Hand drive lever - black - lockable.6 RP-BL-CP 867 Hand drive lever - red - lockable.6 - TECHNICAL INFORMATION, see page H44 RP-BL-CN 87 Hand drive bearing - protection IP44. - TECHNICAL INFORMATION, see page H44 RP-BL-CN 9 Hand drive bearing - protection IP66. - TECHNICAL INFORMATION, see page H44 RP-BL-CH 87 Extension shaft - length 6 mm. - TECHNICAL INFORMATION, see page H44 MECHANICAL INTERLOCKING MOTOR DRIVES To the hand drive Type Product code Description Weight [kg] Packing [pc] RP-BL-CB 88 For circuit breaker/switch-disconnector in fixed design. - TECHNICAL INFORMATION, see page H4 - Both circuit breakers must be equipped with hand drive (at least with a hand drive unit and hand drive lever). By Bowden Type Product code Description Weight [kg] Packing [pc] MB-BL-PP7 987 For circuit breaker/switch-disconnector in fixed design.4 MB-BL-PV8 ) 9 For one fixed and one withdrawable circuit breaker/switch-disconnector.4 MB-BL-VV6 ) 8 For circuit breaker/switch-disconnector in withdrawable design.4 - TECHNICAL INFORMATION, see page H4 ) - Available for sale from second quarter of 6. Type Product code Name - description Operational voltage Weight [kg] Packing [pc] MP-BL-X 6 Motor drive V a.c./d.c. 4. MP-BL-X 6 Motor drive V a.c./ V d.c 4. MP-BL-X-P 64 Motor drive with operations counter V a.c./d.c. 4.4 MP-BL-X-P 6 Motor drive with operations counter V a.c./ V d.c TECHNICAL INFORMATION, see page H47 H9

10 BLS, BL6S - Commercial information ACCESSORIES Type Product code Name - description Weight [kg] Packing [pc] OD-BL-KS 9 Insulating barriers - for switching unit in the fixed.64 - In case of reversed connection (supply to terminals, 4, 6), must be installed also on lower side. - Not included with each order of switching unit in the fixed design. OD-BL-KS8 Insulating barriers - for withdrawable device.4 - Must always be installed on withdrawable device when clamp or block type terminals are used for its connection. OD-BL-KS 8 Terminal cover - for circuit breaker/switch-disconnector in the fixed design with rear connection - Increases degree of protection of connection point to IP..87 OD-BL-KS4 94 Terminal cover - for withdrawable device with front.68 - Intended for withdrawable device with front connection. - We recommend its installation on both sides of withdrawable device for increasing safety in servicing electrical device. OD-BL-KS 9 Insulating grommets - for rear connection. - Intended for fixed design of switching unit and withdrawable device with rear connection. - Insulate connecting sets of rear connection from switchgear structure. - We recommend installing on all connecting sets with rear connection. OD-BL-UP 6 Locking-type lever.4 - Enables locking circuit breaker in switched off manually position. - For locking, up to three padlocks may be used with max. shaft cross-section of 4 6 mm OD-BL-VP 94 Bolt sealing insert. - Provides sealing for: overcurrent release cavity cover OD-BL-KA Connecting cable - for connecting circuit breaker accessories in withdrawable design ( wire). SO-BL- Position indicator - signals circuit breaker/switchdisconnector position in withdrawable design - TECHNICAL INFORMATION, see page H. OD-BL-MS 48 Mounting bolts - for withdrawable device.44 - bolts M8x6 OD-BL-KT 464 ON button cover - for motor drive, cover can be sealed - TECHNICAL INFORMATION, see page H47.9 H

11 BLS, BL6S - Commercial information PURCHASE ORDER EXAMPLE You need to find out a 6 kva distribution transformer with rated current 9 A with expected replacement for a kva transformer and rated current 4 A. Supposedly, there is higher harmonic distortion. You need to indicate the status of the principal contacts and you wish to control your circuit breaker remotely with V a.c. The incoming and out coming lines of the circuit breaker will be formed by Cu busbars. OD-BH-MS SE-BL-6-DTV OD-BL-KS BL6SE PS-BL- MP-BL-X Your purchase order: (do not enter the greyed text in your purchase order) NUMBER TYPE PRODUCT CODE pc BL6SE 44 - switching unit with 6A rated current and 6 ka rated short-circuit ultimate breaking capacity - part of the switching unit are insulating barriers(od-bl-ks) set of installation bolts to install the switching unit(od-bl-ms) pc SE-BL-6-DTV 9 - overcurrent release to protect transformers and lines with rated current up to 6 A and with stepping down I r = 4 % I n pc PS-BL- - auxiliary switch to indicate the status of the main contacts ( make contacts and break contacts) pc MP-BL-X 6 - motor drive for remote control of the circuit breaker ( V a.c./ V d.c) CUSTOM ASSEMBLY OF CIRCUIT BREAKERS at customer s request warranty not only for components, but for the entire configuration after consulting with OEZ company, based on particular specification of your configuration the delivery term is - 4 weeks extra charge for completion and special packing Your order should include the following specification: circuit breaker switching unit type type, rated current and adjustment of the electronic release connecting terminal types - for input terminals of your circuit breaker - for output terminals of your circuit breaker your mounting demands, type and functions of auxiliary switches your demand for mounting and type of auxiliary releases including rated voltage demand for fitting in a drive - hand drive type including accessories (operating lever, bearing, shaft) - motor drive type including control voltage ad your demand for operations counter, extension cable demanded withdrawable or plug-in breaker design your demand for fitting in the withdrawable device indicating individual positions your demand for sealing the overcurrent release Auxiliary circuitry of the withdrawable design will be installed according to the wiring diagram supplied by the customer. H

12 CIRCUIT BREAKERS, SWITCH-DISCONNECTORS BL6S - Technical information Specifications CIRCUIT BREAKER SWITCH- DISCONNECTOR Type BL6S Series SUPERIOR Dimensions A x B x C + D x x + 6 mm x x + 6 mm Weight kg kg Standards EN IEC 947- Approval marks EN IEC 947- Circuit breaker Switch-disconnector Dimensions Installation Load Wiring of switch-disconnector for DC circuits Number of poles Rated current I n 6,,, 6 A - Rated normal current I u 6 A 6 A Rated operating current I e - 6 A Rated operating voltage U e max. 69 V a.c. - max. 69 V a.c. max. 44 V d.c. Rated frequency f n /6 Hz /6 Hz Rated pulse withstand voltage U imp 8 kv 8 kv Rated insulation voltage U i 69 V 69 V Utilization category (selectivity) 69 V a.c. A, B - Utilization category (switching mode) 69 V a.c. 44 V d.c. - - AC-B DC-B Rated short-time withstand current I cw / t ka/ s ka/ s U e = 69 V a.c. short-circuit breaking capacity Rated ultimate I cu / U e 8 ka/ V a.c. (rms value) ) 6 ka/ 4 V a.c. 4 ka/ V a.c. - ka/ 69 V a.c. Off-time at I cu ms - Rated short-circuit service breaking capacity (rms value) Rated short-circuit making capacity (peak value) I cs / U e 4 ka/ V a.c. 6 ka/ 4 V a.c. ka/ V a.c. - ka/ 69 V a.c. I cm / U e 4 ka/ 4 V a.c. 4 ka/ 4 V a.c. 4 ka/ 44 V d.c. Losses per pole at I n = 6 A W W Mechanical endurance cycles cycles Electrical endurance 4 cycles 4 cycles Frequency of switching cycles/hr cycles/hr Operating force N N Front-side device protection IP4 IP4 Terminals protection IP IP Operating conditions Reference ambient temperature 4 C 4 C Ambient temperature range -4 + C -4 + C Working environment dry and tropical climate dry and tropical climate Pollution degree Max. elevation m m Seismic resistance g ( 8 ) Hz g ( 8 ) Hz Design modifications Front/rear connection / / Plug-in design Withdrawable design Accessories Switches - auxiliary / relative / signal / early / / / / / / Shunt trip / with signal switch Undervoltage release / with early switch with signal switch / / Front hand drive / side drive right / left / / Mechanical interlocking to the hand drive / by Bowden / / Motor drive / with operations counter / / Locking type lever Bolt sealing insert / additional overcurrent release cover / / available, unavailable, + in preparation ) - In case circuit breaker connection is reversed (input terminals, 4, 6, output terminals,, ), I cu does not change. H

13 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Wiring diagram Circuit breaker with accessories Recommended wiring of the control circuits Motor drive Auxiliary trips cavity no. Withdrawable device Connecting cable TEST Main circuit Switches auxiliary auxiliary relative relative.4 PS-BL-. SE-BL T T T cavity no. cavity no. cavity no. cavity no. 4 Withdrawable device Connecting cable SP-BL-X... SV -BL-X Q L+ ON OFF B X 7 4 A B 7 4 SSI M P or J A B SO ZV -B L X V Q PS-BL- PS-BL- PS-BL- NC NO C MP 6 X 6 9 N- MP motor drive - MP-BL-X... M motor P storage unit X connector to connect control circuits SSI switch signalling MANUAL (NO-C)/AUTO (NC-C) modes B recommended wiring of the control circuits ON push-button OFF push-button Q motor drive circuit breaker, see page H SO 4 ZV -B L 4 6 X J switching unit - BLSE, BL6SE Q main contacts T, T, T current transformers V trip-free mechanism SP-BL-X... undervoltage release SV-BL-X... shunt trip SE-BL overcurrent release - SE-BL-J , SE-BL TEST push-button to test release ZV-BL withdrawable device - ZV-BL-6- X, X connecting cable for the withdrawable device - OD-BL-KA SO, SO contacts indicating positions of plug-in or withdrawable devices - SO-BL- - see page H H

14 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Specifications States of switches in the circuit breaker cavities Cavity,, 4 Circuit breaker state Lever position of circuit breaker State of the main contacts Switched on Switched off manually or electrically by drive Switched off by the overcurrent release, auxiliary release or by TEST push-button Note: - contact open, - contact closed PS-BL- PS-BL- Location of cavities in switching unit BLSE BL6SE Connecting and installation Power circuit Connected with Cu/Al busbars or cables, and possibly cables with cable lugs. For greater connecting options, connecting sets are produced (see page H6). Generally, conductors from supply are connected to input terminals,,, (N) and conductors from load to terminals, 4, 6, (N). However, it is possible to reverse this connection (switching of input and output terminals) without limiting rated short-circuit ultimate breaking capacity I cu ) In case of reversed connection, circuit breaker/ switch-disconnector must be provided with OD- BL-KS insulating barriers also on the side of terminals, 4, 6 (for detailed information, see page H7). Recommended cross-sections of cables, busbars and flexibars for fixed, plug-in and withdrawable designs I n [A] Cable S [mm ] Busbars W x H [mm] Cu Al Cu Al x x 8 6 x 8 x 4 8 x 4 x 4 x ; x x x x 8 x 4 x 4 x x 6 x 4 4 x 4 x x (4) ) 4 x 4 x x 6 (4) ) x x ) ) - Withdrawable device connected by x x mm Cu busbar can be loaded with max. 4 A. For 6 A loading, the withdrawable device must be connected with x x mm busbar. We recommend painting the connecting busbars. Input and output conductors/busbars must be mechanically reinforced to avoid transmitting electrodynamic force to the circuit breaker/ switch-disconnector during short-circuiting. The way of connecting the power circuit must observe the circuit breaker s deionization spaces (see page H7). Auxiliary circuits Switches, shunt trips or undervoltage releases are connected using flexible. mm Cu conductors to terminalson these devices. Auxiliary circuits of the withdrawable design are connected using a connector. Maximum circuit breaker/switch disconnector loads in accordance with ambient temperature Circuit breaker/switch-disconnector BLS - connection Cu busbars x x 6 mm to pole o C o C 6 o C 6 o C 7 o C A A A A 98 A Circuit breaker/switch-disconnector BL6S - connection Cu busbars x x 6 mm to pole o C o C 6 o C 6 o C 7 o C 4 A 4 A 4 A 6 A A Circuit breaker/switch-disconnector BL6S - connection Cu busbars x x mm to pole o C o C 6 o C 6 o C 7 o C 6 A 4 A 46 A 4 A A H4

15 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Connecting and installation Connecting sets specifications Type I max [A] Cable - ranges of connection diametercross-sections S [mm ] Cable type Sector-shaped conductor, stranded Sector-shaped conductor, solid Round conductor, stranded Round conductor, solid Busbars and cable lugs W x H [mm] Technical information CS-BL-W 8 x ( 7 4 ) Cu / Al x ( 9 ) Cu / Al x ( 8 ) Cu / Al x ( 7 4 ) Cu / Al pg. H9, H, H6 CS-BL-W 7 4 Cu / Al 9 Cu / Al 8 Cu / Al 7 4 Cu / Al pg. H9, H, H6 CS-BL-B x Cu / Al x Cu / Al x Cu / Al x Cu / Al pg. H, H6 CS-BL-B x Cu / Al x Cu / Al x Cu / Al x Cu / Al pg. H, H7 CS-BL-B4 6 4 x Cu / Al 4 x Cu / Al 4 x Cu / Al 4 x Cu / Al pg. H, H7 CS-BL-A x... pg. H8 CS-BL-A 6 x... pg. H8 CS-BL-A 6 x... pg. H4 CS-BL-A 6 x... str. H Front connection - busbars Rear connection CS-BL-A OD-BL-KS OD-BL-KS Nm Nm CS-BL-A F F OD-BL-KS F F OD-BL-KS F F OD-BL-KS H

16 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Connecting and installation Front connection - x Cu, Al cables Front connection - x Cu, Al cables (not for BLSE switching unit) CS-BL-W CS-BL-W CS-BL-W Nm F F OD-BL-KS OD-BL-KS Nm F F -Nm CS-BL-W F F CS-BL-W OD-BL-KS Front connection - cables x Cu/Al cables - CS-BL-B connecting sets x Cu/Al cables - CS-BL-B connecting sets 4 x Cu/Al cables - CS-BL-B4 connecting sets F F -Nm OD-BL-KS CS-BL-W CS-BL-B. BL...SE OD-BL-KS CS-BL-B. Nm OD-BL-KS H6

17 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Deionization spaces A, B, C - minimum deionization space free of earthed metal parts B= C=4. A= Applicable for operational voltage U e 69 V V a.c./d.c. (d.c. only for switch-disconnector) USE OF INSULATING BARRIERS AND TERMINAL COVERS WITH CIRCUIT BREAKERS AND SWITCH-DISCONNECTORS FIXED DESIGN - front connection - terminals,, - OD-BL-KS insulating barriers must always be installed on circuit breaker/ (upper side) switch-disconnector. - terminals, 4, 6 a) If circuit breaker/switch-disconnector is connected to the supply using terminals, 4, 6, (lower side) OD-BL-KS insulating barriers must always be installed on it. b) If circuit breaker/switch-disconnector is connected on lower side using clamp or block type terminals, OD-BL-KS insulating barriers must always be installed on it. - rear connection - terminals,, - OD-BL-KS insulating cover or OD-BL-KS insulating barriers must always be (upper side) installed on circuit breaker/switch-disconnector. - We recommend installing OD-BL-KS insulating grommets with all sets for rear connection. WITHDRAWABLE DESIGN - terminals, 4, 6 - If circuit breaker/switch-disconnector is connected on lower side using clamp or (lower side) block type terminals, OD-BL-KS insulating barriers must always be installed on it. - We recommend installing OD-BL-KS insulating grommets with all sets for sets rear connection. - front connection - terminals,, - If withdrawable device is connected on upper side using clamp or block type (upper side) terminals, OD-BL-KS8 insulating barriers must always be installed. - In all other cases, we recommend installing OD-BL-KS4 insulating cover on upper side of the device - terminals, 4, 6 - If withdrawable device is connected on lower side using clamp or block type (lower side) terminals, OD-BL-KS8 insulating barriers must always be installed. - In all other cases, we recommend installing OD-BL-KS4 insulating cover on lower side of withdrawable device. H7

18 7 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, front connection Drilling positions BLS. 6 BL6S M x ø Connecting busbar modification 4 x ø Fixed design, rear connection (připojovací sady CS-BL-A, CS-BL-A) Openings for insulation grommets BLS 8 BL6S 6 6 R4 6 8 H8

19 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, clamp type terminals (connecting sets CS-BL-W) - not for BLSE switching unit Fixed design, clamp type terminals (connecting sets CS-BL-W a CS-BL-W) - not for BLSE switching unit H9

20 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, block type terminals (CS-BL-B) ø6 Fixed design, block type terminals (CS-BL-B) 4,,, ø6 7, ø6 H

21 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, block type terminals (CS-BL-B4) ø6 7. ø6 Fixed design, front hand drive Hand drive lever - lockable (RP-BL-CP, RP-BL-CP) 46 8 RP-BL-CK RP-BL-CP R H

22 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, front hand drive, adjustable lever Switchgear door modification 46 BL... RP-BL-CK RP-BL-CH RP-BL-CN.. 9 RP-BL-CP.. min. ø4 4 x ø, Hinge of switchgear door 9 98 min. 67 max. SWITCHGEAR DOOR Mechanical interlocking RP-BL-CB Switchgear door modification min. 6 x ø x ø x ø9 Hinge of switchgear door H

23 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Fixed design, motor drive MP-BL-X... Lockable using three padlocks R Fixed design, signalling unit SB-BL- 47 4, H

24 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Withdrawable device ZV-BL-6- Drilling positions 9 4 x ø9 4 x ø MAX Withdrawable device, front connection (CS-BL-A connecting sets) x M H4

25 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Withdrawable device, rear connection (CS-BL-A connecting set) Drilling positions 6. 4 x ø9 MAX Withdrawable device, clamp type terminals (CS-BL-W connecting set) H

26 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Withdrawable device, clamp type terminals (CS-BL-W and CS-BL-W connecting sets) Withdrawable design, block type terminals (CS-BL-B) Operating position ø6 H6

27 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Withdrawable design, block type terminals (CS-BL-B) ø6 ø6 Withdrawable design, block type terminals (CS-BL-B4) ø6 ø6 H7

28 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Withdrawable design Operating position Checking position H8

29 BLS, BL6S - Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions Withdrawable device, hand drive Operating position Checking position Withdrawable device, motor drive MP-BL-X Operating position Checking position 4, 88, 8, 7, H9

30 BLS, BL6S - Technical information WITHDRAWABLE DEVICE Withdrawable device ZV-BL-6- Circuit breaker in withdrawable design Description Withdrawable design of the circuit breaker / switch-disconnector is intended for demanding industrial applications where rapid exchange of the circuit breaker, frequent checking and both visual and conductive disconnection of the circuit are needed. Withdrawable device must be fitted with connecting sets: CS-BL-A x - for front connection or CS-BL-A x - for rear connection For mounting withdrawable device to switchgear, use installation bolts OD-BL-MS, see page H. Circuit breaker position Circuit breaker in withdrawable design has three positions:. inserted (operating position). withdrawn (checking position). removed Power circuit - To connect busbars and cable lugs, use connection set CS-BL-A (front connection) or CS-BL-A (rear connection). - For connection using cables, it is necessary in addition to a connection set CS-BL-A or CS-BL-A to use connection sets shown on page H6. - The way of connecting the power circuit must observe recommendations (see page H4) as well as deionization space (see page H7). Auxiliary circuits These are connected using -wire cable OD-BL-KA. Circuit breaker accessories in plug-in design Circuit breaker in withdrawable design has same accessories as fixed circuit breaker. Position signalling SO-BL- Withdrawable device can be may be provided with up to four switches for signalling the circuit breaker s switchedon position, see table. Advantages and enhanced safety for operator: remote signalling of circuit breaker s switched-on position (position of locking is not signalled) checking of circuit breaker and accessories function in the checking position locking of withdrawable device against inserting circuit breaker, locking of circuit breaker in withdrawn (checking) position - locking by means of padlocks visible and conductive disconnection of the power circuit easy exchange of circuit breakers in case of failure Connecting cable OD-BL-KA Position signalling SO-BL- States of switches SO-BL- in withdrawable device according to circuit breaker and arrestment positions Circuit breaker position State of switch Switched on (locked or not locked) Other positions Note: - contact open, - contact closed 4 Position signalling SO-BL- Specifications SO-BL- Type SO-BL- Rated operating voltage U e V a.c. Rated frequency f n /6 Hz Rated operating current I e /U e 6 A / V a.c. Arrangement of contacts Connection cross-section S. mm Terminal protection (connected switch) IP For wiring diagram of circuit breaker in withdrawable device with accessories, see page H. H

31 BLS, BL6S - Technical information WITHDRAWABLE DEVICE Recommended wiring of circuit breaker in plug-in design with motor drive L+ Motor drive control circuits Q ON Inserting and withdrawing circuit breaker with motor drive - each time before inserting or withdrawing the circuit breaker we recommend first to turn the AUTO/MANUAL switch on the motor drive to the MANUAL position - more operating information can be found in the operating instructions - not adhering to this procedure or failing to follow the recommended wiring could mean that the circuit breaker will not successfully turn on at the first attempt OFF B MANUAL Motor drive Switches relative AU TO Circuit breaker in withdrawable design with motor drive X Wiring diagram description Symbol Description NC MP X NO SSI C 6 6 N- M 9 P 4.4 PS-BL cavity no. 4 MP motor drive MP-BL-X... M motor P storage device X terminal strip to connect control circuits SSI switch indicating AUTO (NO-C)/MANUAL (NC-C) modes B recommended wiring of the control circuits (control circuits not included in motor driver delivery) ON make push button OFF break push button Q motor drive circuit breaker for V a.c. LSN 4C/ for V a.c. LSN C/ for V d.c. LSN-DC 4C/ for V d.c.lsn-dc C/ Changes in states of switches in cavities of switching unit when inserting and withdrawing circuit breaker State before insertion/withdrawal State after insertion/withdrawal Circuit breaker state before insertion Circuit breaker state before withdrawal State of switches before insertion - withdrawn position State of switches before withdrawal - inserted position State of switches after insertion - inserted position State of switches after withdrawal - withdrawn position Cavity,, 4,, 4 Lever position of circuit breaker State of the main contacts 4 PS-BL- 4 PS-BL- 4 PS-BL- 4 PS-BL- Switched on Switched off manually or by motor drive Switched off from the switched-on state by the release or TEST button Note: - contact open, - contact closed H

32 BL6S - Technical information OVERCURRENT RELEASES The electronic overcurrent release consists of a separate and interchangeable unit, which is supplied with the BL6SE... switching unit. By exchanging the overcurrent release, the range of the circuit breaker s rated current can be easily changed. Releases for the BL6SE... switching unit are produced in four current ranges I n = 6,, and 6 A. Including their adjustment, the releases cover rated currents ranging from to 6 A. Depending upon the needs for adjusting the release s tripping characteristic to the protected device and to the variability of the characteristic with regard to selectivity, the following release devices are available: DTV They have one type of characteristic with adjustable I r and I rm. MTV8 They have more kinds of characteristics with adjustable I r, t r and I rm. U They have universal characteristic, with the greatest variability in adjustment: I r, t r, I rmv, t v and I rm. DTV, MTV8, U Proper functioning of releases does not depend on the form of current in the power circuit. The function of the release is supported by a microprocessor, which processes a sampled signal of the power circuit and recalculates it to obtain an rms value. Therefore, digital releases are suitable for protecting circuits where the sinusoidal current is distorted by high harmonics (e.g. circuits with controlled rectifiers, power factor compensators, pulse loading, and the like). All the releases protect a circuit against short-circuiting and overloading. Setting of selective cascading of circuit breakers is especially enabled by the U release. Tripping characteristic of the releases is independent of the ambient temperature. The release is affixed to the switching unit by two bolts. The translucent cover over the adjustment controls can be sealed. Tripping characteristic adjustment for release DTV a MTV8 The tripping characteristic of overcurrent releases is defined by standard EN The characteristic is adjusted in two zones using latched switches on the overcurrent release unit: L - is a zone of low overcurrents and includes the area of thermal protection. I - is a zone of high overcurrents and includes protection against ultimate short-circuit currents. DTV t Ir L I. Dependent release (thermal) L The dependent release MTV8 is adjusted using two switches, I r and t r. The first of these, the I r switch, is used to adjust the circuit breaker s rated current. The characteristic moves on the current axis. By turning the other switch (t r ), the time is adjusted after which the circuit breaker will trip while passing through 7. I r. The tripping characteristic thus moves on the time axis. Using the tr switch, it is possible to set a total of 8 characteristics. Four characteristics are available for motors protection. Breaking times correspond with the release class A,,,. By changing tr it is possible to select the characteristic according to the required motor starting (light, medium, heavy or very heavy starting). For protecting transformers and lines, 4 characteristics can be set. It is not possible to turn the device back on right after the dependent release has been actuated and circuit breaker tripped. The release must be allowed to cool off, because it has a thermal memory. The memory can be disabled by turning the restart switch from the normal T t position to the T position. The dependent release remains active, and only its thermal memory is inactivated. Switching off the thermal memory should be used only in welljustified cases, and with the knowledge that there could be rising temperature in the protected device with repeated tripping. The dependent release DTV is adjusted using one switch I r. Using the I r switch, the circuit breaker s rated current is adjusted, with the characteristic moving on the current axis. By means of its internal circuitry, the release is set to one type of characteristic, TV.. Independent instantaneous release (short-circuit trip) I The independent instantaneous release in designs DTV and MTV8 is adjusted using one I rm switch. The I rm switch is used for setting up the short-circuit current that, upon its being reached or exceeded, causes instantaneous tripping of the circuit breaker. Regulation of the short-circuit release takes in settings for the characteristic appropriate for protecting lines and motors. The wave form of the tripping characteristics is adjusted using latched switches on the release s front panel according to the needs of the protected device. A visual demonstration on setting the tripping characteristic can be found in the SICHR program (see Tripping characteristics of DTV and MTV8 releases with load The tripping characteristic from the cold state indicates the tripping times during which it is assumed that, up to the moment when an overcurrent develops, no current is flowing through the circuit breaker. The tripping characteristic tripped from warm state indicates the tripping times during which it is assumed that, before the moment when an overcurrent develops, current is flowing through the circuit breaker. Characteristics of MTV8 t Ir L I electronic releases are independent of the ambient temperature and are plotted in a cold state. Digital releases enable simulation of a release in warm state. The tripping times become shorter in a steady state, as shown in the following graph. The steady state is a period during which the characteristic does not change. If the circuit breaker is loaded with a reduced current for at least minutes, the tripping times will be cut by a half. If the load is less than 7% of I r, the tripping time does not become shorter. I[%] r Tripping time shortening DTV, MTV8 with load T - When tripping from the release s warm state, the tripping time of the characteristic is cut short during the standstill time tu by coefficient k. Thermal standstill time of the characteristics For all kinds of characteristics t r the thermal standstill time for MTV8 a DTV releases is t u min. During this time, the short-circuit tripping time t v is cut short from the cold-state characteristic by the coefficient k. The real tripping time is t s = k. t v Example The shortening constant can be read from the graph. With steady current 8% of I r the real tripping time will be shortened to: t s =.74. t v k [ ] time shortening coefficient I r [A] adjusted rated current of the overcurrent release t v [s] tripping time of the release derived from the characteristic t s [s] real tripping time of the release tripped from warm state t u [s] standstill period for particular characteristics Overcurrent releases are set by the manufacturer I r = min Restart = T (t) I rm = min t r = TV, min T tr Irm Irm I I H

33 BL6S - Technical information OVERCURRENT RELEASES Tripping characteristic adjustment, release U U L S I used only in well-justified cases, and with the knowledge that there could be rising temperature in the protected device with repeated tripping. Tripping time shortening with load t Ir tr. Delayed independent release S The delayed independent release has the function of a delayed short-circuit release. It is used to set up a selective cascade of circuit breakers. It is set up using specifications I rmv and t v. T Irmv ItOFF ItON tv Irm The tripping characteristic of overcurrent releases is defined by standard EN The characteristic is adjusted in three zones using latched switches on the overcurrent release unit: L - is a zone of low overcurrents and includes the area of thermal protection. S - is a zone of medium overcurrents and includes longdistance short-circuit protection for lines. Intentional delay in tripping of these low short-circuit currents can be used to achieve selectivity of protective devices. This type of delay can be set only in self-contained releases (full version). I - is a zone of high overcurrents and includes protection against ultimate short-circuit currents without time delay. I t - Characteristic setting in ON position represents a constant value of energy passed through. If fuses are used as protective elements for outgoing branch feeders, it is possible to adjust the selective part of the characteristics to better suit the shape of the fuse characteristics.. Dependent release (thermal) L The dependent release U is adjusted using two switches, I r and t r. Using the first switch, I r, the circuit breaker s rated current is adjusted. The characteristic is moved on the current axis. Turning the second switch, t r, adjusts the time after which the circuit breaker will trip while passing through 7. I r. The tripping characteristic thus moves on the time axis. Using the t r switch, a total of 8 characteristics can be set. Breaking times correspond with the release class A,,,. It is not possible to turn the device back on right after the dependent release has been actuated and circuit breaker tripped. The release must be allowed to cool off, because it has a thermal memory. The memory can be disabled by turning the restart switch from the normal T t position to the T position. The dependent release remains active, and only its thermal memory is inactivated. Switching off the thermal memory should be I I rmv is an n-multiple of current I r (I rmv = n I r ). It is a shortcircuit current that, within the span of I rmv to I rm, will trip the circuit breaker with delay t v, where t v is a delay set up for switching off the release. The delayed independent release actuates the circuit breaker if the current in the circuit reaches at least the preset n-multiple and lasts at least the preset delay time t v. The independent release can be disabled by setting the parameter n (I rmv = n I r ) into the. position. Parameter t v can be set to values with respect to the energy that passed through l t (switch position l t on). The preset time values are then applicable for currents more than x current I r. Tripping times of k-multiples of I r for k < are defined as follows:. Independent instantaneous release I The independent instantaneous release has the function of a short-circuit release. It is set up only on parameter I rm. I rm is short-circuit current that, upon its being reached or exceeded, causes the circuit breaker instantaneously to switch off. It is set up directly in ka on the release. The wave form of the tripping characteristic is adjusted using latched switches on the release s front panel according to the needs of the protected device. A visual demonstration on setting the tripping characteristic can be found in the SICHR program (see Tripping characteristics of U release with load The tripping characteristic from the cold state indicates the tripping times during which it is assumed that, up to the moment when an overcurrent develops, no current is flowing through the circuit breaker. The tripping characteristic tripped from warm state indicates the tripping times during which it is assumed that, before the moment when an overcurrent develops, current is flowing through the circuit breaker. Characteristics of electronic releases are independent of the ambient temperature and are plotted in a cold state. Digital releases enable simulation of a release in warm state. The tripping times become shorter in a steady state, as shown in the following graph. The steady state is a period during which the characteristic does not change. If the circuit breaker is loaded with a reduced current for at least minutes, the tripping times will be cut by a half. If the load is less than 7% of I r, the tripping time does not become shorter. T - When tripping from the release s warm state, the tripping time of the characteristic is cut short during the standstill time tu by coefficient k. Thermal standstill time of the characteristics For all kinds of characteristics t r the thermal standstill period for U releases is t u min. During this time, the short-circuit tripping time t v is cut short from the cold-state characteristic by the coefficient k. The real tripping time is t s = k. t v Example The shortening constant can be read from the graph. With steady current 8% of I r the real tripping time will be shortened to: t s =.74. t v I[%] r k [ ] time shortening coefficient I r [A] adjusted rated current release t v [s] tripping time of the release derived from the characteristic t s [s] real tripping time of the release tripped from warm state t u [s] standstill period for particular characteristics Overcurrent releases are set by the manufacturer I r = min Restart = T (t) I rm = min t r = min t v = min, I t - ON I rmv = min H

34 BL6S - Technical information OVERCURRENT RELEASES DTV - DISTRIBUTION Protecting lines and transformers Description The SE-BL-...-DTV release is intended only for the BL6SE... switching unit. The operation of the release is controlled by a microprocessor. The release is outfitted with a thermal memory that can be disabled by turning a switch on the front panel from position T (t) to position T (). After disabling the thermal memory, the thermal release remains active. A practical advantage of the release is a specially designed tripping characteristic that provides for optimal exploitation of transformers up to. I n. Another advantage of this release is the simple adjustment of the tripping characteristic. Set-up includes only rated current and the tripping level of the short-circuit release. The reaching of 8% and % of I r is indicated by LED diodes on the front panel denoted as I > 8% of I r and I > % of I r. On the lower part of the release cover are photocells for communicating with the SB-BL- signalling unit. Specifications - adjustable Type I n [A] I r [A] restart I rm [ka] SE-BL-6-DTV 6, 6 7, 9, 4, 6 4, 4 4, 48, 7, 6 T () T (t) Tripping characteristic 6 t [min] min L Ir max SE-BL-...-DTV Ir Irm SE-BL--DTV 4, 4 4, 48, 7, 6 6, 68 7, 76 8, 87 9, T () T (t). 7 9 t [s] In= 6A In= A In= A In= A In= 6A Irm[kA ] I SE-BL--DTV, 77, 6 6, 68 7, 76 8, ,,, T () T (t) In= A In= A In= 6A Irm[kA] Irm[kA ] Irm[kA ] SE-BL-6-DTV 6 6, 68 7, 8 87, 9,,, 7, 44, 6 T () T (t) H4

35 BL6S - Technical information OVERCURRENT RELEASES MTV8 - MOTORS Direct protection for motors and generators Possibility for protecting lines and transformers Description The SE-BL-...-MTV8 release is intended only for the BL6SE switching unit. The operation of the release is controlled by a microprocessor. The release is equipped with a thermal memory that can be disabled by turning a switch on the front panel from position T (t) to position T (). After disabling the thermal memory, the thermal release remains active. A practical advantage of the release is a specially designed tripping characteristic that provides for optimal exploitation of transformers up to. I n. Specifications - adjustable Type I n [A] I r [A] t r [s] (7. x I r ) restart I rm [ka] SE-BL-6-MTV8 6, 6 7, 9, 4, 6 4, 4 4, 48, 7, 6 (TV ) (TV ) (TV ) (TV ) (M ) 8 (M 8) (M ) (M ) T () T (t) A total of 8 characteristics can be set on the release. From these, in mode M there are 4 characteristics for motors protection and another 4 characteristics in mode TV for protecting transformers and lines. The shape of each characteristic can be changed using a selector switch. When one or two phases fail, in the M-characteristic mode, the switch will open with a 4 s delay (so-called undercurrent release). Another parameter for adjusting the release is rated current, which is adjusted in a range of.4 to. of I n and the shortcircuit tripping level. The reaching of 8% and % of I r is indicated by LED diodes on the front panel denoted as I > 8% of I r and I > % of I r. On the lower part of the release cover are four photocells for communicating with the SB-BL- signalling unit. SE-BL--MTV8 SE-BL--MTV8 4, 4 4, 48, 7, 6 6, 68 7, 76 8, 87 9,, 77, 6 6, 68 7, 76 8, ,,, (TV ) (TV ) (TV ) (TV ) (M ) 8 (M 8) (M ) (M ) (TV ) (TV ) (TV ) (TV ) (M ) 8 (M 8) (M ) (M ) T () T (t) T () T (t) SE-BL-6-MTV8 6 6, 68 7, 8 87, 9,,, 7, 44, 6 (TV ) (TV ) (TV ) (TV ) (M ) 8 (M 8) (M ) ( M) T () T (t) H

36 BL6S - Technical information OVERCURRENT RELEASES MTV8 - MOTORS Tripping characteristic SE-BL-...-MTV8 6 min Ir Characteristic "TV" max Ir tr Irm TV 6 min Ir Characteristic "M" max Ir tr Irm M t [min] t [s] In= 6A In= A In= A In= 6A L tr t [min] t [s] L In= 6A In= A In= A In= 6A 8 tr 8... I. I.... In= 6A Irm[kA ].. In= 6A Irm[kA ]... In=A Irm[kA ]... In=A Irm[kA ]... In=A Irm[kA ]... In=A Irm[kA ]... In=6A Irm[kA ]... In=6A Irm[kA ] H6

37 BL6S - Technical information OVERCURRENT RELEASES U - UNIVERSAL Protecting complicated loads or those not specified in advance Description The release SE-BL-...-U is intended only for switching unit BL6SE... The release is equipped with a thermal memory that can be disabled by turning a restart switch on the front panel from the position T (t) to position T (). After disabling the thermal memory, the thermal release remains active. A practical advantage of the release is its maximum flexibility for adjusting the tripping characteristic. With its possibility for setting I t = constant and I t = constant, it is optimal from the selectivity viewpoint for its interaction with fusing devices. Specifications - adjustable I rmv [A] = (n x I r ) Type I n [A] I r t r [s] (7. x I r ) n t v [ms] I t restart I rm [ka], 6., 7, 9, on, 4, 6 8, 4, SE-BL-6-U 6 4, 4 8, 4, 48 9, off, 4, 6 7, 6 8, T () T (t) The reaching of 8% and % of I r is indicated by LED diodes on the front panel denoted as I > 8% of I r and I > % of I r. On the lower part of the release cover are photocells for communicating with the SB-BL- signalling unit. SE-BL--U 4, 4 4, 48, 7, 6 6, 68 7, 76 8, ,, 4, 6 8,,, 4, 6 on off T () T (t) , 8,,.,. SE-BL--U 77, 6 6, 68 7, 76 8, ,, , 4, 6 8,,, 4, 6 on off T () T (t) 7 9, 8, 8 6, 68., SE-BL-6-U 6 7, 8 87, 9,,, 7, , 4, 6 8,,,, 4, 6 on off T () T (t) , 6 8, H7

38 BL6S - Technical information OVERCURRENT RELEASES U - UNIVERSAL Tripping characteristic SE-BL-...-U 6 min Ir SE-BL-...-U max I rm v=(..) x Irmin Ir tr Irm v tv Irm 6 min Ir SE-BL-...-U max I rm v=(..) x Irmin Ir tr Irm v tv Irm t [min] I n= 6A I n=a I n=a I n=6a L I rm v=(..) x Irmax t [min] I n= 6A I n=a I n=a I n=6a L I rm v=(..) x Irmax t [s]... t v [ms] (I t=off) S t r[s] I t [s]... t v [ms] (I t=on) S t r[s] I.. In= 6A I rm[ka].. In= 6A I rm[ka] In= A I rm[ka].. In= A I rm[ka] In= A I rm[ka].. In= A I rm[ka] In= 6A I rm[ka].. In= 6A I rm[ka] H8

39 BL6S - Technical information OVERCURRENT RELEASES U - UNIVERSAL Tripping characteristic SE-BL-...-U 6 t [min] I n= 6A I n=a I n=a I n=6a min L Ir SE-BL-...-U max I rm v=(..) x Irmin I rm v=(..) x Irmax Ir tr Irm v tv Irm t r [s] 6 t [min] I n= 6A I n=a I n=a I n=6a min L Ir SE-BL-...-U max I rm v=(..) x Irmin Ir tr Irm v tv Irm I rm v=(..) x Irmax t r [s] t [s] S t [s] S... t v [ms] (I t=off) I... t v [ms] (I t=on) I.. In= 6A I rm[ka].. In= 6A I rm[ka] In= A I rm[ka].. In= A I rm[ka] In= A I rm[ka].. In= A I rm[ka] In= 6A I rm[ka].. In= 6A I rm[ka] H9

40 BLS, BL6S - Technical information SIGNALLING UNITS SB-BL- Description The SB-BL- signalling unit is a modular accessory for the BLS and BL6S circuit breakers and collaborates with the electronic releases SE-BL-. -DTV, SE-BL-. - MTV8 and SE-BL-...-U. It is intended for applications in automated-control systems. The unit signals reaching a certain current value in a circuit and the tripping of the circuit breaker by releases (dependent, independent, undercurrent) - user has a options to set up (by steps, using a rotary switch) an amount of current he wishes to indicate if it has been reached - the options are 7; 8; 9; ; ; 4; 6 or 8% I r (refer to the Table below for more details) Local indication regarding the state of the circuit breaker and the protected circuitry is carried out by LED indicators on the front panel of the unit The information on the state of the circuit breaker is transferred from the release to the signalling unit by means of optical coupling Remote indication on the state of the circuit breaker and the protected circuitry is ensured by a relay, the make and break contacts of which are pulled into the terminal strip on the unit - relays to indicate tripping of dependent or undercurrent and independent releases have storage - after the storage relay is activated by tripping of a release, it is necessary to reset the relay using the front panel RESET switch or by an external push button remotely The supply voltages are presented in the table The main power supply and the reset circuit are not concurrently conformable with conditions for safe separation of the circuits The external RESET button must be connected using a screened cable or a twisted wire with maximum resistance of the loop Ohm The signalling unit will not work without power supply! DIMENSIONS, see page H Specifications Type SB-BL- Rated operating voltage U e V a.c. / d.c. Protection tube fuse T,6 A Rated frequency f n /6 Hz Current draw (rms) max. at U e V a.c./d.c. 4 V a.c./d.c. 48 V a.c./d.c. V a.c./d.c. V a.c./ V d.c. 7 ma 7 ma ma 6 ma ma Rated operating current I e / U e AC- 8 A / V a.c. (of relay contacts) I e / U e DC-. A / V d.c., 8 A / V d.c. Connection cross-section S. mm Power circuit status indication Signalling (relay contacts) LED Reaching < 7 % I r + % I r + + 7; 8; 9; ; ; 4; 6; 8 + Settings + + Release tripping By dependent/undercurrent + + / + Independent + + Connecting, - supply 6,7 - external RESET button 9,, - relay contacts indicating preset I r,,4 - relay contacts indicating reaching % I r,6,7 - relay contacts indicating tripping by dependent or undercurrent releases 8,9, - relay contacts indicating tripping by independent release (instantaneous or delayed ones) H4

41 BLS, BL6S - Technical information AUXILIARY SWITCHES Specifications Type PS-BL- PS-BL--Au ) Rated operating voltage U e 6 V a.c. 6 4 V d.c. 6 V a.c. 6 V d.c. Rated isolation voltage U i V V Rated frequency f n /6 Hz /6 Hz Rated operating current I e /U e AC- 6 A/6 V 4 V, A/4 V,. A/ V AC-, DC-.4. A/ V, I e /U e DC- A/6 V,.7 A/ V,. A/4 V.4./6 V Thermal current I th 6 A, A Arrangement of contacts Connection cross-section S. mm. mm Terminal protection (connected switch) IP IP ) - PS-BL-...- Au is not suitable to control electromagnetic loads Arrangement of contacts Number of contacts Contact types + break + make Functions and names of switches according to their location in cavities Switch location Switch name Switch function Cavities, 4 Relative switch to indicate tripping of the circuit breaker by releases, TEST push button or by motor Cavities, Auxiliary switch to indicate the position of the main contacts Location of cavities in switching unit BLSE BL6SE.4 PS-BL-. Switches auxiliary auxiliary relative PS-BL- PS-BL PS-BL- 4.4 relative cavity no. cavity no. cavity no. cavity no. 4 H4

42 SHUNT TRIP Specifications BLS, BL6S - Technical information Type SV-BL-X Rated operating voltage U e 4, 48,,, 4, V a.c. 4, 48,, V d.c. Rated frequency f n /6 Hz Input power at. U e <. VA < W Characteristic U.7 U e the circuit breaker must trip Time to switch-off ms Loading time Connection cross-section S. mm Terminal protection (connected releases) IP Location in cavity no. Circuit breaker switched off by shunt trip Main contacts 4 6 Auxiliary switch Location of cavities in switching unit BLSE BL6SE Auxiliary switch Relative switch L Relative switch B SV-BL-X t[ms] N- B Circuit breaker states and lever positions of circuit breakers Circuit breaker state Lever positions of circuit breaker Switched on Switched off by releases or by TEST button Switched off manually or electrically by drive H4

43 BLS, BL6S - Technické informace UNDERVOLTAGE RELEASE Specifications Type SV-BL-X Rated operating voltage U e 4, 48,,, 4, V a.c. 4, 48,, V d.c. Rated frequency f n /6 Hz Input power at. U e <, VA < W Characteristic ) U.8 U e circuit breaker is possible switch on U. U e the circuit breaker must trip Time to switch-off ms Loading time Connection cross-section S. mm Terminal protection (connected releases) IP Location in cavity no. ) - Tripping of the undervoltage release can be delayed using the delay unit BZ-BL-X, for more detailed information, see page P. Circuit breaker switched off by undervoltage release Main contacts 4 6 Auxiliary switch Location of cavities in switching unit BLSE BL6SE Auxiliary switch Relative switch L Relative switch A SP-BL-X t[ms] N- A Circuit breaker states and lever positions of circuit breakers Circuit breaker state Lever positions of circuit breaker Switched on Switched off by releases or by TEST button Switched off manually or electrically by drive H4

44 HAND DRIVE Description The hand drive is the facility of the circuit breaker which enables circuit breakers BL8S and BL6S to be controlled locally by applying rotary movement on the lever, e.g. for switching electrical equipment on and off. Modular design of the drives enables easy installation on the circuit breaker after removing the cavity cover from the circuit breaker. The drive and its accessories is ordered separately according to your choice, see page H9. BLS, BL6S - Technical information Fig. - FOR DIMENSIONS, see page H The hand drive enables to control the circuit breaker through the front panel or through the switchgear door, the outlet for the operating shaft is protected as has the protection code for bearings, IP44 or IP66. Hand drive operating lever can be furnished with an extension shaft which makes possible to control the circuit breaker also in deeper switchgears. In order to enhance safety for the operator of the electrical equipment, the mechanism of the drive is furnished with locking system preventing the switchgear door from opening when the circuit breaker is in closed position. When the circuit breaker in position manual open, the drive handle can be locked up using the built-in cylinder type lock (FAB) and as many as three padlocks with shank diameter up to 4 7 mm. When the drive lever is in position manual open, it is possible to remove the handle. The circuit breakers with hand drives can be provided with mechanical interlocking system, see page H4. Fig. - FOR DIMENSIONS, see page H Specifications Switchgear door locking in the circuit breaker state Type Description Colour Locking while the circuit breaker is in OFF Protection switched on or off by release Length [mm] RP-BL-CK Hand drive unit - yes RP-BL-CP Hand drive lever black yes RP-BL-CP Hand drive lever red yes RP-BL-CN Hand drive bearing - - IP44 yes - RP-BL-CN Hand drive bearing - - IP66 yes - RP-BL-CH Extension shaft H44

45 BLS, BL6S - Technical information MECHANICAL INTERLOCKING RP-BL-CB Mechanical interlocking It provides interlocking of two circuit breakers so that they cannot be on-state simultaneously, but always only one of them. It is possible to use the locking device between two circuit breakers BLS or BL6S or between circuit breakers BLS and BL6S. Both circuit breakers must be furnished with a hand drive (at least with the hand drive unit and hand drive lever), see page H44. In order to use locking, it is necessary to adhere to the dimensions that are shown in Fig. and. 4 4 x ø Fig. Fig. MB-BL-PP7 Mechanical interlocking by Bowden Provides mechanical interlocking of two circuit breakers so breaker. For interlocking, circuit breakers can be outfitted with that they cannot both be tripped simultaneously, but only one a hand or motor drive. To use interlocking, it is absolutely of them at a time. necessary to comply with the dimensions that are shown Interlocking can be used between two BLS or BL6S on pg. H46. circuit breakers or between a BLS and a BL6S circuit Type of mechanical interlocking MB-BL-PP7 MB-BL-PV8 MB-BL-VV6 Combination of circuit reaker/ switch-disconnector designs fixed - fixed fixed - withdrawable withdrawable - withdrawable Fig. - Mechanical interlocking by Bowden between fixed and withdrawable BL circuit breakers H4

46 BLS, BL6S - Technical information MECHANICAL INTERLOCKING Mechanical interlocking - option for locating circuit breakers/switch-disconnectors 4 Rmin=7 47 ø. Rmin=7,9 7, or -4 H46

47 BLS, BL6S - Technical information MOTOR DRIVES DIMENSIONS, see page H Description The motor drive is part of circuit breaker accessories enabling you to switch the circuit breaker on and off remotely. Modular design of the drives enables easy installation on the circuit breaker after removing the cavity cover from the circuit breaker. Modeion circuit breakers with motor drives can be used in the most demanding industrial applications such as protection of standby sources, synchronization of two sources, etc. and anywhere it is necessary to ensure automated and unmanned operation of electrical equipment. As the motor drives are equipped with spring storage to accumulate energy necessary for activation, it is possible to turn on the circuit breaker in times up to 7 ms. Releasing of the storage device and turning on the circuit breaker is ensured by a closing coil included in standard equipment of every motor drive. The time before the circuit breaker breaks contact on account of a motor drive is approx.. s. This tripping method is applicable for controlling technological entities. When faster circuit breaker tripping is required (e.g. emergency STOP button), it is possible to use the motor drive combined with undervoltage release or shunt trip. On the motor drive front panel there is a switch selector to select drive modes with a possibility to indicate remotely the state of this switch. The first mode is automatic remote control (position AUTO). This is the standard position in automatic operation. The other mode is manual control (selector position MANUAL), the motor drive does not need any voltage to perform its operation. When the selector is in position AUTO, it is possible to switch on and off remotely with the push buttons that must be wired to the connector on the drive. When the drive is in MANUAL mode, the circuit breaker can be switched on using the green button on the front part of the drive cover and to switch it off with the red TEST button on the overcurrent release unit. The function of the remote control ON button in MANUAL MODE is locked up, whereas the function of the remote control OFF button remains active for safety reasons. The motor drive makes it simple to control the circuit breaker when there is a loss of control voltage. In MANUAL mode, it is possible to wind up the spring storage assembly by repeated rotation of the foldable handle. After the storage is wound up, the circuit breaker can be turned on using the green button on the front part of the insulation cover of the drive and it can be turned off using the red TEST button on the overcurrent release. The motor drive, unlike the circuit breaker, recognizes only two fixed positions In position one, the circuit breaker is in on-state. If the circuit breaker in AUTO mode is put in off-state by some overcurrent releases, auxiliary trip devices or from a distance, the PS-BL - switch (included in motor drive delivery) will generate a pulse to load the spring storage mechanism automatically as a result of electrical linkage with the circuit breaker. If the switch is not placed in cavity or 4, no automatic loading process will take place. In the second fixed position the circuit breaker is switched off and the loaded drive device is ready to activate the circuit breaker after receiving the control pulse. The presence of the control voltage in the drive is indicated by a steadily lit green LED indicator below the drive plate. If the indicator is not lit, the position of the circuit breaker lever need not comply with the correct positions of the power contacts. The drive may be furnished with an electromechanical operations counter. The drive can be locked up in off-state position using the built-in cylinder type lock and using as many as three padlocks with the shank diameter max. 7 mm. Before the drive is locked up, it is necessary to turn the drive unit switch to MANUAL mode position, to withdraw the drive unit yellow lockup strip and to insert the padlock shank into the oval opening in the lockup strip. When a cylinder type lock is used, the lockup strip will run out a little. An OD-BL-KT cover can be affixed to the drive s turn-on switch and then sealed. The cover prevents turning on the circuit breaker from the drive panel. Push button cover OD-BL-KT Parametry Type MP-BL-X, MP-BL-X -P Operational voltage U e, V a.c., V d.c. Rated frequency f n / 6 Hz Control pulse length for switching on > ms ) Control pulse length for switching o. > ms ) Time to switch-on Time to switch-off Frequency of ON/OFF cycles Frequency of cycles - immediately one after another ON/OFF Mechanical endurance Input power Protection Rated operating current of the switch selector AUTO / MANUAL ) - for sequence of control pulses, see page H AC DC V a.c., V a.c. V d.c., V d.c. I e / U e <7 ms 6 ms cycles/min 8 cycles cycles VA W LSN 4C/, LSN C/ LSN-DC 4C/, LSN-DC C/ 6 A/ V a.c. H47

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S H MOULDED CASE CIRCUIT BREAKERS BL6S H BL6S COMMERCIAL INFORMATION Switching units, withdrawable device...h4 Overcurrent releases...h5 Signalling units...h5 Residual current monitor...h6 Current transformers

More information

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S MOULDED CASE CIRCUIT BREAKERS BH6N, BH6S F BH6N, BH6S COMMERCIAL INFORMATION Switching units, withdrawable device, plug-in device...f4 Switch-disconnector unit...f6 Connecting sets...f7 Mounting sets...f9

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

3VT5 Molded Case Circuit Breakers up to 1600 A

3VT5 Molded Case Circuit Breakers up to 1600 A VT5 Molded Case Circuit Breakers up to A Catalog Technical Information VT5 Molded Case Circuit Breakers up to A General data /2 - Overview Standard circuit breakers, releases / - Selection and ordering

More information

3VT5 Molded Case Circuit Breakers up to 1600 A

3VT5 Molded Case Circuit Breakers up to 1600 A VT Molded Case Circuit Breakers up to 6 A Catalog General data Siemens AG Overview Connecting sets 4 Switching unit 6 7 8 9 6 4 Accessories 7 8 9 4 NSO_9a 4 6 7 8 9 Molded case circuit breaker Multiple

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Overcurrent releases - description, specifications, characteristics specifications specifications description... BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC6N Tento výrobek byl vyvinut za finanční podpory ze státních fondů prostřednictvím Ministerstva průmyslu a obchodu. D BC6N COMMERCIAL INFORMATION Circuit breakers...d4

More information

3VT2 Molded Case Circuit Breakers up to 250 A

3VT2 Molded Case Circuit Breakers up to 250 A VT Molded Case Circuit Breakers up to 5 A Catalog VT Molded Case Circuit Breakers up to 5 A General data / - Overview Circuit breakers Switch disconnectors / - Overview / - Selection and ordering data

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

DATA SHEET 3VT3 MCCB ACCESSORIES

DATA SHEET 3VT3 MCCB ACCESSORIES Issued June 7 DATA SHEET VT MCCB ACCESSORIES Based on Siemens Catalog LV 8 VT Molded Case Circuit Breakers up to A 7 Accessies and Components es Overview Type designation accding to contact arrangement

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00

More information

Devices for switching and control

Devices for switching and control Devices for switching and control WWWOEZCOM Motor starters MOTOR STARTERS SM Basic function Switching and protection of motors up to 2 A Protection against short-circuit and protection against overload

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE-10B-1N-030AC The device is a combination of residual current circuit breaker and circuit breaker.

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

3VT1 Molded Case Circuit Breakers up to 160 A

3VT1 Molded Case Circuit Breakers up to 160 A Siemens AG 4 VT Molded Case Circuit Breakers up to 6 A Catalog Technical Information VT Molded Case Circuit Breakers up to 6 A / General data / Circuit breakers Switch disconnectors Accessories and Components

More information

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50 SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS Type SPB SPB SPF SP4.. SP50 Rated current I n 60 A / 0 A / 400 A 60 A / 0 A / 400 A 60 A / 0 A / 400 A / / 60 A Rated voltage AC/DC U n 690 V 690 V 690 V

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Siemens AG VT3 Molded Case Circuit Breakers up to 630 A

Siemens AG VT3 Molded Case Circuit Breakers up to 630 A Siemens AG VT Molded Case Circuit Breakers up to 6 A Catalog General data Overview Connecting sets 5 6 Switching unit 7 8 9 Accessies f plug-in and withdrawable devices 9 5 7 8 5 Accessies 6 6 7 8 9 NSO_a

More information

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K Varius SUMMARY OF MODELS OF FUSE-RAILS Type FSR00 FSR1 FSR2 FSR3 Rated operating current I e 160 A 250 A 400 A 630 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V Size 00 1 2 3 Busbar spacing

More information

3VT3 Molded Case Circuit Breakers up to 630 A

3VT3 Molded Case Circuit Breakers up to 630 A Siemens AG 4 VT Molded Case Circuit Breakers up to 6 A Catalog Technical Infmation VT Molded Case Circuit Breakers up to 6 A / General data / Circuit breakers Switch disconnects Accessies and Components

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Residual current circuit breakers with conditional shortcircuit

Residual current circuit breakers with conditional shortcircuit LFE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS LFE Residual current circuit breakers with conditional shortcircuit current 6 ka. They react to sine-wave residual current (type

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

SENTRON 3VT Molded Case Circuit Breakers up to 1600 A

SENTRON 3VT Molded Case Circuit Breakers up to 1600 A Siemens AG 4 SENTRON VT Molded Case Circuit Breakers up to 6 A Catalog LV 6 4 VT Molded Case Circuit Breakers up to 6 A VT Molded Case Circuit Breakers up to 5 A The products and systems described in this

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka) Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE ( ka) The device is a combination of residual current circuit breaker and circuit breaker For

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

IP20 degree of protection; IP40 degree of protection after installation in a distribution box RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus DISTRIBUTION SOLUTIONS GSec Gas-insulated switching and isolating apparatus GSec is a three-position SF6 gas-insulated switchdisconnector designed for use in medium voltage switchgear for secondary distribution

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs. SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka) Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) Standard type for common use in building and housing installations up to 3 A, 230/400 V a.c. They react to alternating sine-wave

More information

NH-Fuse system Low voltage

NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristic Rated currents I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SX2

More information

PIX-H Metal-clad switchgear up to 17.5kV

PIX-H Metal-clad switchgear up to 17.5kV AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...

More information

15-I73E CAT REF.

15-I73E CAT REF. & www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka) Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka) They react to both alternating sine-wave residual current and pulsating direct current (type A) For protection: against accidental

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

14-I73E CAT REF.

14-I73E CAT REF. & www.terasaki.co.jp -I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work GE Electrical Distribution Gerapid High Speed DC Circuit Breakers On the move imagination at work Gerapid High Speed DC Circuit Breakers To stay up and running today, you need equipment that delivers both

More information

Horizontal fuse disconnects

Horizontal fuse disconnects THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.

More information