125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Size: px
Start display at page:

Download "125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request"

Transcription

1 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for any low voltage circuit. Conformity to standards IEC EN VDE (1992) NBN EN BS EN Approvals and certifications (1) Bureau Véritas Lloyd s Register of Shipping CEBEC (Belgium) FI (Finland) ASEFA KEMA CCA GOST (Russia) BBJ Poland (attestation of verification) PSA E G RENAULT EB (1) In progress for certain ratings. General characteristics Fully visible breaking. High thermal and dynamic withstand. Arduous utilisation categories (AC-22 and AC-23). Good electrical and mechanical endurance. High resistance to humidity (supplied tropicalised ). Available on request Early break auxiliaries. 9 and 12 poles up to 1600 A. 3 pole + solid neutral. Early break advanced neutral for networks charged with harmonics. Conducting neutral. Neutral earthing stud. Connection terminals bolts not supplied from 800 to 4000 A. Double rated Neutral. A. 26

2 Illustrations Front operation Overview (for further details, please see the installation instructions supplied with each device). sirco_281_b_1_x_cat Direct front handle. 2. Door interlocked external handle. 3. Shaft extension. 4. IP2 Auxiliary contacts. 5. Switch body only. 6. Spacers. 7. Terminal shrouds. 8. Shrouded distribution block. 9. Inter phase barrier. External right-side operation (consult us) sirco_335_a_1_x_cat Door interlocked external right-side handle. 2. Shaft extension. 3. IP2 auxiliary contacts. 4. Switch body only. 5. Spacers. 6. Terminal shrouds. 7. Shrouded distribution block. 8. Inter phase barrier. A. 27

3 125 to 4000 A Front operation 3 and 4 pole sirco_295_a_2_cat No. of poles Switch body only Direct handle Door interlocked external handle Shaft extensions for external handle Auxiliary contacts Terminal shrouds Terminal screens (1) (1) Black* (2)(3) (2)(4) (1) (1) Red (2)(3) P (2)(4) (1) (1) (1) (1) Black* Red S2 type Black IP55* Black IP Red IP mm mm* mm st NO/NC contact nd NO/NC contact (2)(3) (2)(3) (2)(3) (2)(4) (2)(4) (2)(4) (1) (1) (2)(3) (2)(4) (1) (1) * Standard. (1) Available enclosed (see page A.37 and A.38 ). (2) Top or bottom. (3) 2 sets required to shroud top and bottom terminals on 3/4 pole switch. (4) Order 2 references to shield top and bottom terminals. For more informations: see pages. A. 28

4 DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Load break switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle Front operation 3 and 4 pole sirco_301_a_2_cat No. of poles Switch body only Direct handle Door interlocked external handle** Shaft extensions for external handle** Auxiliary contacts Terminal screens (1) (1) (1) (2)(3) CD (1) (1) (1) Black* S4 type Black IP65* Red IP mm mm* mm st NO/NC contact (2)(3) (2)(3) Red nd NO/NC contact (2)(3) Black IP65* mm (2)(3) Red IP mm* (2)(3) Black* Red Black IP65* mm* included included * Standard. ** S type handle not suitable for 2000 to 4000 A ratings. (1) Available enclosed (see page A.37 and A.38 ). (2) Top or bottom. (3) Order 2 references to shield top and bottom terminals. For more informations: see pages. A. 29

5 125 to 4000 A Front operation 6 and 8 pole sirco_188_a_1_cat (1) No. of poles (1) Switch body only Direct handle Door interlocked external handle Shaft extensions for external handle Auxiliary contact Terminal shrouds Terminal screens P 6 P Black* S2 type Black IP55* Red/Yellow IP mm* mm P (1)(2) (1)(2) 6 P (1) (1) P (1)(2) (1) P P P P P Black* Red Black* Red S3 type Black IP65* Red/Yellow IP mm mm* st NO/NC contact nd NO/NC contact (1)(2) 6 P (1)(2) (1)(2) / (1) 6 P (1) (1) 6 P (1) (1) P (1) (1) * Standard. (1) Top or bottom. (2) 4 sets required to shroud top and bottom terminals on 6/8 pole switch. For more informations : see pages. A. 30

6 DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Load break switches picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle No. of poles Handle colour HT / Black , / Black , / Red , / Black , / Red , / Black , / Red , / Black , / Red , / Black , / Red , / Black , / Red ,0 acces_150_a_1_cat acces_152_a_2_cat Door interlocked external handle S2-type handle S4-type handle acces_151_a_1_cat S3-type handle The door interlocked external operation includes a padlockable handle, an escutcheon and must be combined with a shaft extensions No. of poles Handle type Handle colour External IP (1) HT 3/ S2 Black IP ,0 3/ S2 Black IP ,0 3/ S2 Red/Yellow IP ,0 6/ S2 Black IP ,0 6/ S2 Black IP ,0 6/ S2 Red/Yellow IP ,0 6/ S3 Black IP ,0 6/ S3 Red/Yellow IP ,0 3/ S4 Black IP ,0 3/ S4 Red/Yellow IP ,0 3/ V Black IP ,0 3/ V Red IP ,0 3/ V Black IP ,0 3/ - Red consult us,0 (1) IP: protection rating according to IEC standard. acces_187_a_1_cat S-type handle adapter Enables new S type handles to be mounted using old fixing holes for replacement or retrofit applications. Adds 12 mm to the depth. Référence Colour External IP (1) Pack qty Référence HT Black IP ,0 (1) IP: protection rating according to IEC standard. A. 31

7 125 to 4000 A acces_198_a_1_cat Alternative S-type handle cover colours For single lever handles S2, S3- type and for double lever handles S4-type. Other colours: please consult us. Colour Pack qty Handle type HT Light grey 50 S2, S ,0 Dark grey 50 S2, S ,0 Light grey 50 S ,0 Dark grey 50 S ,0 acces_143_b_1_cat acces_144_b_1_cat acces_202_a_1_x_cat Shaft extensions for external handle X Standard length: mm, mm, mm, mm, mm, mm. Other lengths: please consult us. For 3/4 pole Dimension X (mm) Shaft length (mm) HT , , *, , , , , *, , , , , *, , , , *, , , *, , *,0 For 6/8 pole Dimension X (mm) Shaft length (mm) HT , *, , *, , , *,0 * Standard. A. 32

8 acces_076_a_1_cat Auxiliary contacts Pre-break and signalling of positions 0 and I: - 1 to 2 NO/NC auxiliary contacts, - 1 to 4 NO + NC auxiliary contacts, - 1 to 2 low level NO/NC auxiliary contacts. NO/NC AC: IP2 with front operation. Connection to the control circuit 6.35 mm fast-on connection. Electrical characteristics operations. NO/NC contacts for 3/4 pole No. of AC HT st , nd , st included nd included NO/NC contacts for 6/8 pole No. of AC HT st , nd ,0 NO + NC contacts for 3/4 pole No. of AC HT st , nd ,0 Low level NO/NC contacts for 3/4 pole No. of AC HT st , nd ,0,0,0 Contact type Nominal current (A) Operating current I e (A) 230 VAC 400 VAC 24 VDC 48 VDC AC-12 AC-13/15 AC-12 AC-13/15 DC-12 DC-13 DC-14 DC-12 DC-13 DC NO/NC NO+NC Door mounting kit Kit enables door mounting facility for the range. For 3/4 pole direct front operation No. of poles HT , , , ,0 acces_077_a_1_cat Terminal shrouds Top or bottom protection against direct contact with terminals or connection parts. Advantage Perforations allowing remote thermographic inspection without removal. The terminal shrouds also provide phase separation s from 125 to 630 A. No. of poles Position HT /6 P top or bottom (1)(2), / top or bottom (1)(2), /6 P top or bottom (1)(2), / top or bottom (1)(2), /6 P top or bottom (1)(2), / top or bottom (1)(2),0 (1) 2 sets required to shroud top and bottom terminals on 3/4 pole switch. (2) 4 sets required to shroud top and bottom terminals on 6/8 pole switch. A. 33

9 125 to 4000 A acces_079_a_1_cat Terminal screens Top or bottom protection against direct contacts with terminals or connection parts. For 3/4 pole No. of poles Position HT top or bottom (1), top or bottom (1), top or bottom (1), top or bottom (1), top or bottom (1), top or bottom (1),0 800 CD 1250 top or bottom (1),0 800 CD 1250 top or bottom (1), top or bottom (1), top or bottom (1), top or bottom (1), top or bottom (1), / top and bottom included,0 (1) Order 2 references to shield top and bottom terminals. For 6/8 pole No. of poles Position HT P top or bottom , top or bottom , P top or bottom ,0 250 top or bottom , P top or bottom , top or bottom , P top or bottom , top or bottom , P top or bottom ,0 top or bottom ,0 repar_020_b_1_cat repar_027_a_2_cat Shrouded distribution block Bottom distribution kit Easy connection of several cables, can be clipped onto a symmetric DIN rail. Easy connection of several equipotential conductors, mounted top of the. Rating (A) Rating (A) No. of poles No. of poles No of feeders per section (mm 2 ) HT 125 3/ 2 x x , / 2 x x x , / 1 x x x ,0 No of feeders per section (mm 2 ) HT x x , x x , x x , x x , x x , x x , x x , x x ,0 A. 34

10 Cage terminals acces_053_a_1_cat X1 Connection of bare copper cables onto the terminals (without terminal lugs). No. of poles HT , , , , , , , ,0 acces_091_a_1_x_cat øx Z A1 Connections Section flexible cable (mm 2 ) Section rigid cable (mm 2 ) Width flexible bar (mm) Stripped over (mm) acces_092_a_1_x_cat C A R A A1 C R ØX X1 Z M M M M20 15 acces_220_c_1_x_cat Copper bars connection kits Fig.1 B A To allow connection between the two power terminals from a same pole for 2000 to 3200 A ratings (Fig. 1 and Fig 2). For 3200 A rating, the connection piece (part A) are delivered bridged from factory. Bolt sets must be ordered separately. Top or bottom flat connection - Fig. 1 Qty to order Part per pole (1) HT Connection piece - part A , Bolt set - part B ,00 22, Connection piece - part A / standard 22, Bolt set - part B ,00 (1) Example for 3-pole device: order 3 times the quantities. acces_222_b_1_x_cat Fig.2 D C A See page A.43, for connection kit assembly. Technical notice for these specific accessories is downloadable from Top or bottom edgewise connection - Fig. 2 Qty to order Part per pole (1) HT Connection piece - part A , T piece - part C (2) 22, Right angle - part D (2) 22,00 22, Connection piece - part A T piece - part C / 1 standard (2) 22,00 22, Right angle - part D (2) 22,00 (1) Example for 3-pole device equipped top only: order 3 times the quantities. (2) Bolt set is provided with the accessories. A. 35

11 125 to 4000 A acces_036_a_1_cat Inter phase barriers Safety isolating separation between the terminals, essential for use at 690 VAC or in a polluted or dusty atmosphere. The terminal shrouds also provide phase separation for s from 125 to 630 A. No. of poles HT , , , , , , / included,0 acces_001_a_1_x_cat acces_158_a_1_x_cat Handle key interlocking accessories Fig. 1 Fig. 3 acces_005_a_1_x_cat Fig. 2 acces_004_c_1_x_cat Fig. 4 Locking in position 0 of the front operation handle: - using a padlock (not supplied) and factory integrated into the handle. From 125 to 1800 A, the padlock on the external front operation handle also locks the door, - using lock (not included): see diagrams opposite, - using undervoltage coil: the can only be closed if the coil is live. For 6/8 pole, please consult us. Locking using RONIS EL11AP lock (not included) No. of poles Operation Figure HT / direct front (1), / external front , / direct front , / external front , / direct front ,0 Locking using CASTELL lock (not included) No. of poles Operation Lock type Figure / external front FS / external front K / external front K / external front K / external front K / external front K Locking using 230 VAC undervoltage coil (other voltages: please consult us) No. of poles Operation HT / external front (2), / direct front (2),0 (1) Front operation handle included. (2) The locking system is mounted directly on the device. A. 36

12 Other specific accessories Mechanical coupling device for making switches with n poles with the same or different ratings. Mechanical interlocking device. bd_03_04_01 Steel enclosure for front operation coff_295_a_1_cat General characteristics Adapted to mechanical risk and dust hazard. S-type black handle lockable in position 0. Protection degree: IP55 / Ik 10 (IP65 on request). Colour: polyester powder RAL Gland plates: top and bottom. Material: XC steel, thickness 1.5 to 2 mm. Coating: epoxy polyester powder. Wall mounting: 4 holes in the back of the casing. Door: solid with hinges. Locking system: 3 mm double-bar key (key supplied). Miscellaneous: 2 earth connection points, disconnectable solid neutral link for 3+N, extension boxes for top and/or bottom connections available, IP20 incoming terminal shrouds. Please consult us. A. 37

13 125 to 4000 A Polyester enclosure for front operation Connection coff_292_a_2_cat coff_230_b_1_gb_cat Top coff_231_b_1_gb_cat Emergency breaking. Breaking for mechanical maintenance. Safety isolation in the vicinity of any low voltage final circuit. Conformity to standards IEC EN EN EN General characteristics Adapted to chemical attack, dust hazard, contamination hazard and atmospheric corrosion. S-type black handle lockable in position 0. Protection degree: IP55 (IP65 on request). Colour: RAL Gland plates: none. Material: glass fibre reinforced polyester. Coating: none. Wall mounting: 4 fixing lugs supplied, not mounted. Locking system: screws. Miscellaneous: high comparative tracking index, high resistance to chemicals, self-extinguishing at 960 C, 2 earth connection points, connection on top switch via a set of descending bars. (1)(2) Bottom Bottom Bottom No. of poles Reference HT Reference HT , , , , , , , , , , , , , , , , , , , ,0 (1) Combined fuse version: please consult us. (2) For rating 16 to 100 A, see page A.18 M & MV. Auxiliary contacts (see page A.33). Terminal shrouds (see page A.33). Connection coff_230_b_1_gb_cat Top coff_231_b_1_gb_cat Bottom Bottom Bottom coff_114_c_1_gb_cat N H M W B Ab Ah Z Z1 D 45 Max. Rating No. of H x W x D connection Weight Weight (A) poles (mm) section (mm 2 ) M N Z Z1 Ah B (kg) Ab B (kg) 125 3/ 360 x 270 x * 125 3/ 360 x 270 x / 360 x 270 x * 160 3/ 360 x 270 x / 540 x 360 x * 250 3/ 540 x 360 x / 720 x 540 x / 720 x 540 x * Please consult us. A. 38

14 (according to IEC ) Thermal current I th (40 C) 125 A 160 A 200 A 250 A 315 A 400 A 500 A 630 A 800 A Rated insulation voltage U i (V) Rated impulse withstand voltages U imp (kv) Rated operational currents I e (A) Rated voltage Load duty category A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) 400 VAC AC-21 A / AC-21 B 125/ / / / / / / / /800 AC-22 A / AC-22 B 125/ / / / / / / / /800 AC-23 A / AC-23 B 125/ / / / / / / / / VAC AC-21 A / AC-21 B 125/ / / / / / / / /800 AC-22 A / AC-22 B 125/ / / / / / / / /800 AC-23 A / AC-23 B 100/ / / / / / / / / VAC (2) AC-20 A / AC-20 B 125/ / / / / / / / /800 AC-21 A / AC-21 B 125/ / / / / / / / /800 AC-22 A / AC-22 B 125/ / / / / / / / /800 AC-23 A / AC-23 B 63/80 63/80 80/ / / / / / / VDC DC-20 A / DC-20 B 125/ / / / / / / / /800 DC-21 A / DC-21 B 125/ / / / / / / / /800 DC-22 A / DC-22 B 125/ / / / / / / / /800 DC-23 A / DC-23 B 125/ / / / / / / / / VDC DC-20 A / DC-20 B 125/ / / / / / / / /800 DC-21 A / DC-21 B 125 (4) /125 (4) 160 (4) /160 (4) 160 (4) /200 (4) 200 (4) /200 (4) 315 (4) /315 (4) 400 (4) /400 (4) 400 (4) /500 (4) 500 (4) /500 (4) 800 (3) /800 (3) DC-22 A / DC-22 B 125 (4) /125 (4) 125 (4) /125 (4) 160 (4) /160 (4) 200 (4) /200 (4) 315 (4) /315 (4) 400 (4) /400 (4) 400 (4) /400 (4) 500 (4) /500 (4) 800 (3) /800 (3) DC-23 A / DC-23 B 125 (3) /125 (3) 125 (3) /125 (3) 160 (3) /160 (3) 200 (3) /200 (3) 315 (3) /315 (3) 400 (3) /400 (3) 400 (3) /400 (3) 500 (3) /500 (3) 800 (3) /800 (3) 500 VDC DC-20 A / DC-20 B 125/ / / / / / / / /800 DC-21 A / DC-21 B 125 (4) /125 (4) 125 (4) /125 (4) 160 (4) /200 (4) 200 (4) /200 (4) 315 (4) /315 (4) 400 (4) /400 (4) 400 (4) /400 (4) 500 (4) /500 (4) 800 (3) /800 (3) DC-22 A / DC-22 B 125 (3) /125 (3) 125 (3) /125 (3) 160 (3) /160 (3) 200 (3) /200 (3) 315 (3) /315 (3) 315 (3) /400 (3) 315 (3) /400 (3) 500 (3) /500 (3) 800 (3) /800 (3) DC-23 A / DC-23 B 125 (3) /125 (3) 125 (3) /125 (3) 160 (3) /160 (3) 200 (3) /200 (3) 315 (3) /315 (3) 315 (3) /400 (3) 315 (3) /400 (3) 500 (3) /500 (3) 800 (3) /800 (3) Operational power in AC-23 (kw) (1)(5) At 400 VAC without pre-break AC 63/63 80/80 100/ / / / / / /450 At 500 VAC without pre-break AC 63/63 63/63 110/ / / / / / /560 At 690 VAC without pre-break AC 55/75 55/75 75/90 90/ / / / / /220 Reactive power (kvar) (5) At 400 VAC Fuse protected short-circuit withstand (6) Prospective short-circuit (ka rms) Associated fuse rating (A) Overload capacity Rated short-time withstand current 0,3 s. I cw (ka rms) Rated peak withstand current (ka peak) (6) Connection Minimum Cu cable section (mm 2 ) x x 185 Minimum Cu busbar section (mm 2 ) x 30 x 5 2 x 40 x 5 Maximum Cu cable section (mm 2 ) x x 300 Maximum Cu busbar width (mm) Min. tightening torque (Nm) Mechanical characteristics Endurance (number of operating cycles) Operating effort (Nm) Weight of switch (kg) Weight of switch (kg) (1) A/B: Category with index A = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or phase barrier. (3) 4-pole device with 2 pole in series by polarity. (4) 3-pole device with 2 pole in series for the + and 1 pole for the -. (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) For a rated operating voltage U e = 400 VAC. A. 39

15 125 to 4000 A (according to IEC ) Thermal current I th (40 C) 1000 A CD 1250 A 1250 A 1600 A 1800 A 2000 A 2500 A 3200 A 4000 A Rated insulation voltage U i (V) Rated impulse withstand voltages U imp (kv) Rated operational currents I e (A) Rated voltage Load duty category A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) A/B (1) 400 VAC AC-21 A / AC-21 B 1000/ / / / / / / / /3200 AC-22 A / AC-22 B 1000/ / / / / / / / /2500 AC-23 A / AC-23 B 1000/ / / / / / / / / VAC AC-21 A / AC-21 B 800/ / / / / / / / /3200 AC-22 A / AC-22 B 800/ / / / / / / / /2000 AC-23 A / AC-23 B 630/ / / / / / / / / VAC (2) AC-20 A / AC-20 B 1000/ / / / / / / / /4000 AC-21 A / AC-21 B 800/ / / / / / / / /2500 AC-22 A / AC-22 B 800/ / / / / / / / /1000 AC-23 A / AC-23 B 200/ / / / / / / / / VDC DC-20 A / DC-20 B 1000/ / / / / / / / /4000 DC-21 A / DC-21 B 1000/ / / / / / / / /2500 DC-22 A / DC-22 B 1000/ / / / / / / / /1600 DC-23 A / DC-23 B 1000/ / / / / (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250/ VDC DC-20 A / DC-20 B 1000/ / / / / / / / /4000 DC-21 A / DC-21 B 1000 (3) /1000 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 2000/ / / /2000 DC-22 A / DC-22 B 1000 (3) /1000 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250/1250 DC-23 A / DC-23 B 1000 (3) /1000 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1000 (3) /1000 (3) 1000 (3) /1000 (3) 1000 (3) /1000 (3) 1000 (3) /1000 (3) 500 VDC DC-20 A / DC-20 B 1000/ / / / / / / / /4000 DC-21 A / DC-21 B 1000 (3) /1000 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250/ / / /1250 DC-22 A / DC-22 B 1000 (3) /1000 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) DC-23 A / DC-23 B 1000 (3) /1000 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1250 (3) /1250 (3) 1000 (3) /1000 (3) 1000 (3) /1000 (3) 1000 (3) /1000 (3) 1000 (3) /1000 (3) Operational power in AC-23 (kw) (1)(5) At 400 VAC without pre-break AC 560/ / / / / / / / /710 At 500 VAC without pre-break AC 450/ / / / / / / / /710 At 690 VAC without pre-break AC 185/ / / / / / / / /750 Reactive power (kvar) (5) At 400 VAC Fuse protected short-circuit withstand (6) Prospective short-circuit (ka rms) Associated fuse rating (A) x x x x Overload capacity Rated short-time withstand current 0,3 s I cw (ka rms) Rated peak withstand current (ka peak) (6) Connection Minimum Cu cable section (mm 2 ) 2 x Minimum Cu busbar section (mm 2 ) 2 x 50 x 5 2 x 60 x 5 2 x 60 x 5 2 x 80 x 5 3 x 100 x 5 3 x 100 x 5 4 x 100 x 5 4 x 100 x 5 4 x 100 x 10 Maximum Cu cable section (mm 2 ) 4 x x x x x Maximum Cu busbar width (mm) Min. tightening torque (Nm) Mechanical characteristics Endurance (number of operating cycles) Operating effort (Nm) Weight of switch (kg) Weight of switch (kg) (1) A/B: Category with index A = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or phase barrier. (3) 4-pole device with 2 pole in series by polarity. (4) 3-pole device with 2 pole in series for the + and 1 pole for the -. (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) For a rated operating voltage U e = 400 VAC. A. 40

16 sirco_198_f_1_x_cat Front operation 125 to 630 A Direct front operation AC AA CA BA CA N J1 W X1 T M T F U1 J2 U T X2 V R 90 G 1. Terminal shrouds A. S2 type handle K Z Y 1 BC AD H C 18 External front operation I 90 Ø Ø 7 28 D min to 1800 A Direct front operation External front operation A 210 A 125 Overall Terminal Rating dimensions shrouds Switch body Switch mounting Connection terminals (A) C D min. AC AD F 3p. F 4p. G H J1 3p. J1 4p. J2 K BC M 3p. M 4p N R T U U1 V W X1 3p. X1 4p. X2 Y Z AA BA CA M = = Z Y 1 90 B U V I 221 min. sirco_325_b_1_x_cat 470 AA = 175 = X1 T T F 90 T X2 28 ø9 330 = = Ø Ø 7 1. Terminal screens A. Handle single lever S3 type B. Handle double lever S4 type Rating (A) Switch body Switch mounting Connection terminals F 3p. F 4p. M 3p. M 4p. T U V Y X1 X2 Z AA CD A. 41

17 125 to 4000 A Front operation 2000 to 3200 A Direct front operation A M I 0 sirco_354_a_1_x_cat J Ø 4.5 Ø Rating (A) Overall dimensions Switch body Switch mounting A 3p. A 4p. J 3p. J 4p. M 3p. M 4p A Direct front operation External front operation A F ø 37 8 ø 4.5 ø sirco_202_c_1_x_cat M = = 45 4 ø x Ø 6.5 Ø 31 3 x Ø Terminal screens 2. Min. length with coupling part for shaft extension (shaft 40 mm): 635 mm 3. Door drilling with RONIS EL11AP lock 4. Door drilling with CASTELL K lock Rating (A) Overall dimensions Switch body Switch mounting A 3p. A 4p. F 3p. F 4p. M 3p. M 4p A. 42

18 Connection terminals 800 to 1000 A CD 1250 A 1250 to 3200 A 4000 A sirco_207_a_1_x_cat ø ø sirco_270_b_1_x_cat 16 x svr_098_a_1_x_cat 12,5 ø12, sirco_213_a_1_x_cat Copper bars connection kits Top terminals Bottom terminals Note: Screws and bolts not suitable for 800 to 4000 A ratings. Fig. 1 Fig. 2 acces_220_c_2_cat acces_224_a_1_cat ,5 96,5 59,5 acces_225_a_1_cat acces_223_b_2_cat ,5 126,5 96,5 66,5 36,5 Door drilling With RONIS EL11AP lock 4 Ø 5.5 Ø 26 With CASTELL K lock for 125 to 1800 A 22 With CASTELL K lock for 2000 to 3200A svr_102_a_1_x_cat Ø 37 4 Ø svr_101_a_1_x_cat Ø 37 2 Ø 6.5 Ø 37 4 Ø sirco_224_b_1_x_cat x Ø 6.5 Ø 31 3 x Ø 6.5 A. 43

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity

More information

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity

More information

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They

More information

What you need to know. Â Conformity to standards

What you need to know.  Conformity to standards SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to

More information

CATALOGUE MARINE APPLICATIONS. Energy performance solutions

CATALOGUE MARINE APPLICATIONS. Energy performance solutions CATALOGUE MARINE APPLICATIONS Energy performance solutions 2017 2018 Marine Certifications Our certified products As an independent manufacturer, we, at Socomec are committed to adapting the range and

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures

Safety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures coff_163_a_1_cat coff_156_b_1_cat Function equipped with SOCOMEC switches provide emergency breaking, breaking for mechanical maintenance and safety isolation in the vicinity of any low voltage final circuit.

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A 2017 CTLOGUE extract SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200 Transfer switches svr_207_a.eps svr_208_a.eps The solution for > Manufacturing > Power

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty

More information

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS

More information

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A Integrated products & solutions The solution for > Iron and steel industry > Cement plants > Paper mills > Sawmills > Hydraulic power packs > Automotive > Mining coff_436_a coff_434_a Strong points Function

More information

Motorised and automatic transfer enclosed switchess

Motorised and automatic transfer enclosed switchess s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

CATALOGUE. Solutions for Power, Control & Safety

CATALOGUE. Solutions for Power, Control & Safety CATALOGUE Solutions for Power, Control & Safety 2015 Contents An independent manufacturer... p.4 Four key applications: the benefit of a specialist... p. 5 A cutting-edge laboratory... p. 6 Socomec in

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

Switching, control and protection solutions for solar applications

Switching, control and protection solutions for solar applications Switching, control and protection solutions for solar applications continuous performance www.socomec.com Summary SIRCO M PV Manually operated modulable and modular switches p. 4 SIRCO MV PV Manually

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Transfer switching solutions

Transfer switching solutions CATALOGUE EXTRACT Transfer switching solutions from 40 to 6300 A 2018 Contents The SOCOMEC Group... Security and reliability for your transfer applications... Remotely operated and Automatic Transfer

More information

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Switch disconnectors

Switch disconnectors Selection Load break switch disconnectors type LK3, 40-120 A Selection guide for 3 and 4-pole switch disconnectors General The LK3 range of switch disconnectors (lth: 40 A to 120 A) is designed for use

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

General Characteristics

General Characteristics from 63 to 31 lbs_037_a he solution for > ain switchboard > Distribution panel > Emergency switching > us tie Function he CEC ensures making and breaking on load and security breaking of any low voltage

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA ENCLOSED SWITCHES SAFETY SWITCHES / ISOLATORS 16-800A TECHNICAL DATA Safety switches / isolators 10A 16A 25A 40A 63A 80A 125A 160A 200A 250A 315A 400A 630A 800A Rated Insulation voltage Ui (V) 690 690

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories

More information

SFS-UFS Single Foot Switches

SFS-UFS Single Foot Switches SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Switches disconnectors with fuse-holders. XNF series TF series

Switches disconnectors with fuse-holders. XNF series TF series Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions THE SANTON FCS-TYPE SWITCH DISCONNECT Superior Switch Solutions The technical information given in this table applies to and pole fuse combination switches. A B NOMINAL RATING 0A A FUSE COMBINATION SWITCHES

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

KATKO Safety Switches:

KATKO Safety Switches: KATKO Safety Switches: Reliability, Economy, Safety KATKO/2007.01/AL 1 KUM 16-25A Dimensions: Overall: 130,4 x 96,4 x 42,0 Mounting holes: 118,0 x 84,0 -Polycarbonate or ABS IP65 enclosure -Excellent UV

More information

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Breakers and Switches. Switches Switch-disconnectors OT and OTM Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

MANUALLY OPERATED CHANGEOVER SWITCHES

MANUALLY OPERATED CHANGEOVER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

25A 25A 32A 40A 40A 63A 63A 80A

25A 25A 32A 40A 40A 63A 63A 80A ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

LOAD BREAK SWITCHES AND SWITCH FUSES

LOAD BREAK SWITCHES AND SWITCH FUSES easy to install LOAD BREAK SWITCHES AND SWITCH FUSES Sixty years of innovation in developing and producing high-quality switches When Mr Kauko Hyryläinen founded KATKO in 1941, one of his key targets

More information

Euroload Changeover Switch

Euroload Changeover Switch Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.

More information

Switch Disconnectors

Switch Disconnectors Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles

More information

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES O S O O CABINETS AND ENCLOSURES XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES II With its extensive ranges, the Legrand offer meets your quality standards and

More information

Switch-disconnectors OT , OETL 3150

Switch-disconnectors OT , OETL 3150 Switch-disconnectors OT 16...2500, OETL 3150 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 Front operated switch-disconnectors OT, OETL 24 Side operated

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

PowerLine OS Switch Fuses A, 690V

PowerLine OS Switch Fuses A, 690V Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7 EP60 Series...7-2 EP100 Series...7-4 EP100 ULH Series...7-6 EP100 UC Series (Branch Circuit Protection)...7-8 Series CA Auxiliary Switch and Bell Alarm...7-10 Series CB Auxiliary Switch and Bell Alarm...7-11

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

LOAD BREAK SWITCHES. Ensto Compact

LOAD BREAK SWITCHES. Ensto Compact LOAD BREAK SWITCHES Ensto Compact Ensto Enclosures and Components Ensto also offers enclosed switches; being assemblies of Ensto Cubo enclosures and load break switches. Ensto is an international industrial

More information

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block. PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

Breakers and Switches. Switches Change-over and transfer switches

Breakers and Switches. Switches Change-over and transfer switches Breakers and Switches Switches Change-over and transfer switches Change-over and transfer switches 16...2500 A Contents: 4 Product overview, features 8 Technical data 8 Manual, motorized and automatic

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link

More information

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description. General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors

More information