Motor Circuit Breakers C3
|
|
- Rodger Lee
- 5 years ago
- Views:
Transcription
1 Motor Circuit Breakers C3 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C3/12 C3/2 Setting Short Part ref Ultimate short circuit breaking/ Setting Short Part ref Ultimate short circuit breaking/ range circuit service capacity < 400V AC range circuit service capacity < 400V AC release max fuse A release max fuse A A A Icu - ka Ics - ka gl/gg A A Icu - ka Ics - ka gl/gg C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ C3/ ) C3/ C3/ ) C3/ ) C3/ ) C3/ ) C3/0 C3/100 Setting Short Part ref Ultimate short circuit breaking/ Setting Short Part ref Ultimate short circuit breaking/ range circuit service capacity < 400V AC range circuit service capacity < 400V AC release max fuse A release max fuse A A A Icu - ka Ics - ka gl/gg A A Icu - ka Ics - ka gl/gg C3/ ) C3/ ) C3/ ) C3/ ) C3/ ) C3/ ) C3/ ) C3/ ) C3/ ) -- No back-up fuse required 1) Back up fuse required if short circuit current at installation point > 0kA
2 Accessories Top mounted auxiliary contact block, max 1 per circuit breaker Contact block 1 C/O contact All C3HQW Contact block 1NO + 1NC contact All C3HQ11 Contact block 1 C/O contact, low level switching All C3HQWE Auxiliary contact block for left hand side mounting, max 1 per circuit breaker Contact block 1NO + 1NC All C3HS11 Contact block 2NO All C3HS20 Contact block 2NC All C3HS02 Signalling switch for left hand side mounting, max 1 per circuit breaker Signalling switch C3/2 1NO + 1NC each Individual tripped and C3/0 C3M11 short circuit signal C3/100 Auxiliary releases for right hand side mounting, max 1 per circuit breaker Under voltage trip 110V All C3U V All C3U V All C3U400 Shunt trip 24V All C3A24 110V All C3A V All C3A230 Enclosures Moulded plastic enclosure with actuator diaphragm, knockouts Protection degree IP with N- and for M2 sealable PE- terminal 4mm width C3/12 C312PF4 72mm width C3/12 C312PF72 Moulded plastic enclosure with Protection degree IP with N- and actuator diaphragm, knockouts PE- terminal 4mm width for M2 sealable C3/2 C32PFH4 72mm width C3/2 C32PFH472 Accessories for Enclosures Emergency stop button Mushroom head, latch twist to release C3/12 C312P44 Indicator light With glow lamps and coloured lenses, red green, yellow, orange and clear C3/ V C3L V C3L V C3L V C3L480
3 Accessories continued Door coupling rotary mechanisms The door coupling rotary operating mechanisms consist of a knob, a coupling driver and an extension shaft (mm x mm). The door-coupling rotary operating mechanisms are designed for degree of protection IP6. The door locking device prevents accidental opening of the cubicle door in the on position of the circuit breaker. The off position can be locked with upto 3 padlocks. Door coupling rotary Ext shaft 130mm C32-100ZH4130 C3/2-100 mechanism black Ext shaft 330mm with support bracket C32-100ZH4330 Emergency stop Ext shaft 130mm C32-100ZHN4130 Door coupling rotary mechanism Red/Yellow Ext shaft 330mm with support bracket C3/2-100 C32-100ZHN4330 Insulated 3-phase busbar system For feeding several modular circuit breakers on standard mounting rails, insulated and shock protected. Rated operational voltage 60V. 3-phase busbars for 2 circuit-breakers C3/12-2 C312-2S2 modular spacing for 3 circuit-breakers C312-2S3 mm for 4 circuit-breakers C312-2S4 for circuit-breakers C312-2S For connecting the 3-phase busbars for circuit breakers of different sizes. Clamping together C3/12 and C3/2 circuit breakers is not possible due to the different modular spacings and the different heights of terminals. Connector modular spacing mm C3/2 left with right hand side C3/12-2 C312-2S2 3-phase busbars for 2 circuit-breakers C30S2 modular spacing mm for 3 circuit-breakers C3/0 C30S3 for 4 circuit-breakers C30S4 Line side terminal Conductor cross section C3/12 C312SE 3-pole, connection from above solid or stranded 6-2mm 2 C3/2 C32SE with end sleeve 4-16mm 2 Conductor cross section C3/2 C32SE 1 conductor 2.-0mm 2 2 conductors 2.-3mm 2 C3/0 C30SE Mounting parts for motor circuit breaker/contactor combination C3/12 3mm DIN rail (DIN 0022) or screw mounting C312-2HU1 breaker and contactor C3/2 C3/12 3mm DIN rail (DIN 0022) or screw mounting C312-2HU2 breaker and reversing and YD contactor C3/2 DIN rail mounting 2x3 DIN rails with 12mm breaker and contactor distances or 7mm DIN rail or screw fixing C3/0 C30HU1 DIN rail mounting 2x3 DIN rails with 12mm breaker and contactor distances or 7mm DIN rail or screw fixing C3/100 C3100HU
4 Accessories continued Busbar adapters Busbar adapter 40mm system for 3 copper busbars acc. to C3/12 C312-2SA40 breaker and contactor Din 46433, width 12, 1mm thickness:, 10mm C3/2 Busbar adapter 60mm system for 3 copper busbars acc. to C3/12 Din 46433, width 12, 1mm thickness:, 10mm C312-2SA60 breaker and contactor or T-Profil C3/2 Link modules For mechanical fixing and electrical connecting between circuit breaker and contactor Link module up to 20A C3/12 C312VD up to 32A C3/2 C32VD up to 0A C3/0 C30VD up to 100A C3/100 C3100VD
5 Dimensions (mm) Circuit-breaker C3/12 C3/2 1) ) 2) 11) ) ) Circuit-breaker C3/0 1) 2) 11) ) Lateral aux. contact 2) Signalling contact Auxiliary release Transverse aux. contact Mounting holes 3mm DIN-rail ) 3mm DIN-rail 1mm high or 7mm DIN-rail 10) 4mm hexagon socket screw 11) Lockable in 0-position with shackle diameter max. mm Circuit-breaker C3/100 11) 10) ) 2) )
Motor Circuit Breakers C4
Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More information3VU13, 3VU16 Circuit-Breakers
3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationSIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates
Motor Starter Protectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Overview Enclosures For stand-alone installation of 3RV20
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationLow voltage switch gear
Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling
More informationComponents for EEx e Panels
Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37
More informationType MS450 MS497. Phone: Fax: Web: - Manual motor protectors
Manual motor protectors Type MS40 MS497 MS40 MS497 Manual motor starters Overload tripping class 10 Overload tripping class 20 FLA adjustment range Single-phase1 Horsepower ratings Three-phase 11V 230V
More informationProtection Equipment
Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection
More informationMotor protective circuit breakers
Motor protective circuit breakers Motor protective circuit breakers MSP Description The MSP0, MSP1 motor starter protectors are compact motor starter protectors for currents up to 52 A which operate according
More informationMotor protective circuit breakers
Motor protective circuit breakers Motor protective circuit breakers MPE 25 Rated current 0,16-32 A Example of MPE configuration: Advantages With overload and short circuit protection Fixed short circuit
More informationIEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors
04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,
More informationProtection Equipment. 5/2 Introduction
Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationAll round protection guaranteed
s With SLR ll round protection guaranteed Betagard MCB 5SL Inspiring Safety nswers for infrastructure. Overview s a culture Siemens has always endeavoured to introduce innovative products worldwide. The
More informationPhone: Fax: Web: -
HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right
More informationProduct index. 4 - Manual motor protectors. Phone: Fax: Web: -
Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationMotor Starter Protectors
Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker
More informationSiemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage
SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution
More informationMS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories
Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10
More informationTechnical Catalogue. Manual Motor Starters MS 116, MS 325, MS 4xx
Technical Catalogue Manual Motor Starters MS 116, MS 325, MS 4xx 37 Manual motor starters Type Series M up to 45 kw (400 V AC) Contents Manual Motor Starter MS 116 0-16 A, 16/50 ka... 6 Manual Motor Starter
More information3VF3 to 3VF8 Circuit-Breakers
3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating
More informationMOULDED CASE CIRCUIT BREAKERS BC160N
D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage
More informationOvercurrent releases - description, specifications, characteristics specifications specifications description...
BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting
More informationPKZ and PKE motor-protective circuit-breakers
PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationSiemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J
Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N
More informationMotor Starter Protectors
Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker
More informationTechnical Catalogue. Manual Motor Starters MS116, MS325, MS4xx ABB
Technical Catalogue Manual Motor Starters MS116, MS325, MS4xx ABB 2 ABB Manual Motor Starters Type Series M up to 45 kw (400 V AC) Contents Manual Motor Starter MS116 0-16 A, 16/50 ka... 6 Manual Motor
More informationProduct index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.
Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type
More informationPANEL-MOUNTING COMPONENTS SWITCHGEAR. Technology
PANEL-MOUNTING COMPONENTS SWITCHGEAR Technology QUADRON CrossLinkBreaker Disconnects and provides fuse protection for currents up to 100A Sizes 000 to 2 can be mounted quickly on DIN EN 50 022 rails using
More informationBulletin 140M Motor Protectors
0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected
More informationMC FRAME SIZE 1 / UP TO 160A
8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable
More informationCOMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33
BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting
More informationMS25, MST25, MS20, MST20
Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationManual Motor Starter MS 116. Technical Catalogue
Manual Motor Starter MS 116 Technical Catalogue The task: Economic fuseless motor protection Know-how in safe-keeping ABB is a renowned manufacturer of electrical motors. But apart from the hardware in
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationLow Voltage Control Gear
Low Voltage Control Gear Quality made in Short Form Catalogue D651E171 Technical catalogues and news under: www.benedict.at Contactors Motor-Starter Mini-Contactors Contactors Overload Relays Compacitor
More informationTechnical Catalogue Manual Motor Starters. MS 116, MS 325, MS 4xx
Technical Catalogue Manual Motor Starters MS 116, MS 325, MS 4xx Manual motor starters Type Series M up to 45 kw (400 V AC) Contents Manual Motor Starter MS 116 0-16 A, 10/30 ka... 6 Manual Motor Starter
More informationProtective Devices: Circuit-Breakers 1 )
Protective Devices: Circuit-Breakers 1 ) /2 Introduction SIRIUS circuit-breakers 1 ) up to 100 A / General data /20 For motor protection /22 For motor protection with overload relay function /23 For starter
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationBasic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors
MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided
More informationCatalog Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC
-148 March 008 Accessories Auxiliary Contacts Side-Mount Auxiliary Contacts Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can
More informationPRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004
PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationShort form catalogue Motor protection and control Manual motor starters
Short form catalogue Motor protection and control Manual motor starters Motor protection and control Index Contents Beneifits 4 Features 5 Overview 6 Manual motor starter MS116 and MS132 8 Manual motor
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for
More informationMotor protection switches M16 20A Main switches S25 25A
Motor protection switches M16 20A Main switches S25 25A DISA Elektro AG Kägiswilerstrasse 33 CH-6060 Sarnen Tel. 041 666 70 50 Fax 041 666 70 49 info@disa.ch www.disa.ch DISA your partner for individual
More informationAir Circuit Breakers
Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationDPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationACS motor protection circuit breakers KT 7 Introduction
Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different
More informationPANEL PANEL MOUNTING COMPONENTS
PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology
More informationCircuit breakers. Panorama. PB111746_30.eps PB111749_30.eps
Protection Circuit breakers Panorama PB76_0.eps PB79_0.eps PB75_0.eps PB75_0.eps PB757_0.eps PB758_0.eps Circuit breakers C60 N0 Performance Number of poles P P P P P + N P + N Width (module 9 mm) 6 8
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationF Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2
Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37
More informationAir Circuit Breakers
Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationTeSys GV2 - GV3 Manual Starters and Protectors
TeSys GV GV Manual Starters and Protectors A stronger, longterm connection Courtesy of Steven Engineering, Inc. 0 Ryan Way, South San Francisco, CA 94080670 General Inquiries: (800) 67048 www.stevenengineering.com
More information3SE3 1 SIGUARD Position Switches
3SE3 SIGUARD Position Switches Metal-enclosed, with Moulded Cable Description Technical data Description In harsh industrial environments and in installations with limited space, the small 3SE3 6 and 3SE3
More informationDPX Electronic + earth leakage
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL
More information3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,
Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,
More informationMotor Controllers + Circuit Breakers
Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions
More informationMC FRAME SIZE 1 / UP TO 160 A
MC FRAME SIZE 1 / UP TO 160 A W CIRCUIT BREAKER 1-POLE UP TO 125 A WITH FIXED THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1C-A, MC1N-A, MC1H-A MC112118 W SCHRACK-INFO For system and line protection Fixed
More informationElectronic Circuit Breaker ESS20-0..
Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode
More informationNPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations
Version:- 3.0 Date of Issue:- Dec 2013 Page 1 of 13 NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations 1. Purpose This document is the technical specification
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationand other modular devices for low voltage installation
Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories
More informationSystem pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationSealed Enclosures. Contact Blocks. Multiple Actuators
Contact Blocks Both N/O & N/C contact blocks and combinations of each are available for the Standard and Heavy Duty ranges of Emergency Stop Switches. Sealed Enclosures All Standard and Heavy Duty range
More informationSelective main circuit breakers S 750 series Technical Data
Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More informationMPW Series. MPW Catalog Number Sequence. Standard Features MPW U004
Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationDPX 160 Thermal magnetic and trip-free switches DPX-I 160
87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationMOULDED CASE CIRCUIT BREAKERS BH630N, BH630S
MOULDED CASE CIRCUIT BREAKERS BH6N, BH6S F BH6N, BH6S COMMERCIAL INFORMATION Switching units, withdrawable device, plug-in device...f4 Switch-disconnector unit...f6 Connecting sets...f7 Mounting sets...f9
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationLow Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A
Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection
More informationPRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MAY 2018 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI
More information3VT Kompaktleistungsschalter bis 630A
Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical
More informationBtdin-RS RCBO 2p Phase + Neutral, neutral on right
Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationSwitch disconnectors and fuse switch disconnectors
Switch disconnectors and fuse switch disconnectors Technology QUADRON CrossLinkBreaker Secures and disconnects currents up to 100A Sizes 000 to 2 can be mounted quickly on DIN EN 50 022 rails using the
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More information