FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
|
|
- Warren Thornton
- 5 years ago
- Views:
Transcription
1 Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually operated multipolar fuse combination switches. They make and break on load and provide safety isolation and protection against overcurrent for any low voltage electrical circuit. Advantages Improved safety Complete isolation of the fuse with double breaking per pole (top and bottom of fuse). Positive break indication. IP2X protection with terminal shrouds front panel. High breaking capacity Protection against overloads and shortcircuits thanks to high breaking capacity fuses ( ka rms). fuser_59_a cat FUSERBLOC 2 to 2 A Specific functionalities for simplified use TEST position for testing control circuits without power using U-type auxiliary contacts. In TEST position, the enclosure door can be opened. Mechanical or electronic fuse melting detection system (see DDMM or FMD). > Improved safety. > High breaking capacity. > Specific functionalities for simplified use. A complete range. > Centred or left side operation, rear connections, plug-in connections. Please consult us. Conformity to standards > IEC > EN > BS EN > NBN EN > IEC > DIN EN > NF EN > IEC > VDE 66- > VDE 66-7 > Standards UL: see FUSERBLOC UL Approvals and certifications () Customised solutions () Product reference on request. fuser_597_a fuser_552_a Multipolar FUSERBLOC Centred operation 88 General Catalogue 2-24
2 What you need to know In addition to the FUSERBLOC rating, product selection also depends on the fuse characteristics and functional specifications, which need to be in accordance with the application. SOCOMEC FUSERBLOC are available for utilisation with NFC, DIN or BS88 fuses. Whether it is pole + switched or pole + solid, the FUSERBLOC 2 to 2 A with direct front operation and external operation is the best suited solution in compact design. From 2 to 4 A, the FUSERBLOC is available in 2, or 4 poles with direct right side operation. From 6 to 25 A, the FUSERBLOC allows direct and external front left or right side operation in 2, or 4 poles. fuser_7_a cat fuser_75_a cat With external operation, it is possible to operate the device in ways: - Front operation - Right side operation - Left side operation. For ratings 2 to 4 A, the flat mounting kit provides a compact solution ideally suited to withdrawable applications. fuser_72_a_2_cat fuser_76_a_2_cat Maintenance of outputs from the DC common bus. The FUSERBLOC LMDC is the most compact solution and the most economical for your maintenance requirements (please consult us). fuser-lm_2_a fuser_74_a cat General Catalogue
3 References BS 88 - External front and side operation - 2 to 6 A Rating (A) Fuse size Frame size Number of poles Reference Switch I- Reference Changeover I - - II External front handle I- TEST External front handle I- TEST External right side handle I - Changeover external front handle I - - II Shaft extensions for handle Terminal shrouds () U type A/C (2) Integrated solid link A A CD 2 A A + switched +solid switched + solid S type IP () S type 4 25 () S type IP () S type IP () 2 mm A A 6 A A2-A 2 2 P P S type 2 S type 25 S type 48 2 S type 2 Standard contact NO A A4 (4) CD 6 A A-A4 (4) A 6 A A4 4 2 P P P IP () () IP () IP () mm P contact NC P A B-B () Standard. (2) 4 auxiliary contacts as standard without additional contact holder. () Top/bottom. (4) For fuse size A4: max diameter mm. 9 General Catalogue 2-24
4 BS 88 - External front and side operation - 2 to 25 A Rating (A) Fuse size Frame size Number of poles Reference Switch I- Reference Changeover I - - II External front handle I- TEST External front handle I- TEST External right side handle I - Changeover external front handle I - - II Shaft extensions for handle Terminal shrouds () U type A/C (2) Integrated solid link CD 2 A A-A4 (5) A 2 P P A B-B A B-B2-B 5 5 A B-B2-B 6 4 A B-B2- B-B4 6 2 P P P P IP () () IP () IP () mm P contact NO contact NC A C-C2 7 8 A C-C2-C 7 25 A D 8 2 P P S type 4 () S type S type 47 () S type 48 2 mm P P S4 type () () Standard. (2) 4 auxiliary contacts as standard without additional contact holder. () Top/bottom. (4) 8 AC as standard without support (the support is for 8 additional auxiliary contacts). (5) For fuse size A4: max diameter mm General Catalogue
5 References (continued) BS 88 - Direct operation - 2 to 6 A Rating (A) Fuse size Frame size Number of poles Reference Side direct operation Reference Direct front operation Side direct handle operation switch Direct front handle Auxiliary contacts Terminal shrouds () Cage terminals Handle key interlocking accessories (2) 64 2 A A CD 2 A A 2 A A 6 A A2-A 2 + switched + solid switched + solid P consult us 625 consult us consult us 2 P consult us consult us consult us contact NO/NC A-type 999 () 2 contacts NO/NC A-type () Standard Standard P consult us A A4 (4) 625 consult us consult us contact NO/NC A-type () CD 6 A A-A4 (4) A 6 A A4 4 2 P consult us consult us consult us 2 P consult us consult us consult us contacts NO/NC A-type () 2 P P consult us 6 A B-B consult us consult us () Max. 2 contacts. (2) Lock not included. () Top/bottom. (4) For fuse size A4: max diameter mm. 92 General Catalogue 2-24
6 BS 88 - Direct operation - 2 to 4 A Rating (A) Fuse size Frame size Number of poles Reference Side direct operation Reference Direct front operation Side direct handle operation switch Direct front handle Auxiliary contacts Terminal shrouds () Cage terminals Handle key interlocking accessories (2) CD 2 A A-A4 (4) A 2 A B-B A B-B2-B 5 5 A B-B2-B 6 4 A B-B2-B-B4 6 2 P consult us consult us consult us 2 P consult us consult us consult us 2 P consult us consult us consult us 2 P consult us consult us consult us 2 P consult us consult us consult us consult us contact NO/NC A-type () 2 contacts NO/NC A-type () 2 P P () Max. 2 contacts. (2) Lock not included. () Top/bottom. (4) For fuse size A4: max diameter mm. BS 88 - Direct operation - 6 to 25 A Rating (A) Fuse size Frame size 6 A C-C2 7 8 A C-C2-C 7 25 A D 8 Number of poles Reference Side direct operation Reference Direct front operation 2 P P Side direct handle operation switch Direct front handle Auxiliary contacts contact NO U-type () contact NC U-type () Terminal shrouds () 2 P P Cage terminals Handle key interlocking accessories (2) () Max.number of U-type auxiliary contacts is 8. (2) Lock not included. () Top/bottom. General Catalogue
7 References NFC and DIN - External front and right side operation - 25 to 25 A Rating (A) / Fuse / Frame size No. of poles Switch I--TEST Changeover switch I--II External front handle TEST external front handle External right side handle Changeover external front handle Shaft for external handle Auxiliary contacts (2) Terminal shrouds () Integrated solid link 6 2 () A x 8 CD 2 A x 8 2 A 4 x 5 + switched + solid 6 42 () () switched + solid () switched + solid 6 44 () () S type IP S type S type IP S type IP mm 4 52 U-type contact A 4 x 5 6 A C 2 2 P () () P () () S type S type Standard A 22 x 58 2 P () () mm 4 2 (2) U-type contact A 22 x A 2 P P IP IP IP P () Available enclosed (see page "Enclosed fuse switches" page XXX). (2) Top/bottom. () Maximum 4 contacts. 94 General Catalogue 2-24
8 NFC and DIN - External front and right side operation - 6 to 25 A Rating (A) / Fuse / Frame size No. of poles Switch I- Changeover switch I--II External front handle TEST external front handle External right side handle Changeover external front handle Shaft for external handle Auxiliary contacts Terminal shrouds (2) Integrated solid link 6 A 6 A 4 25 A 5 4 A P P () () P () () P () () IP IP IP mm 4 2 U-type contact () U-type contact (4) 2 P P A 7 8 A 7 8 A A P 8 26 S type 8 6 () 8 66 () 2 P P 8 28 S4 type P S type mm P P () Available enclosed (see "Enclosed fuse switches" page (2) Top/bottom. () Maximum 4 contacts. (4) Maximum 8 contacts. XXX). General Catalogue
9 References (continued) NFC and DIN - Direct operation - 25 to 25 A Rating (A) Fuse size Frame size No. of poles Direct side operation Direct front operation Direct handle Auxiliary contacts Terminal shrouds Cage terminals Lock for fuse protection cover Handle key interlocking accessories (6) A x 8 CD 2 A x 8 + switched + solid switched + solid ()(2) A-type contact NO/NC 999 () A-type 2 contacts NO/NC () Standard 2 A 4 x switched + solid Standard Standard 5 A 4 x 5 6 A C 2 A 22 x A 22 x 58 2 P consult us 65 5 consult us consult us 2 P consult us 65 6 consult us consult us 2 P 65 2 consult us 65 consult us 65 6 consult us 2 P 65 2 consult us 65 consult us 65 6 consult us (5)(2) (5)(2) A-type contact NO/NC () A-type 2 contacts NO/NC () 2 P 9 26 (4) 9 6 (4) 9 46 (4) A 2 P consult us 65 2 consult us consult us () Direct front operation. (2) Standard. () Maximum 2 contacts. (4) Top or bottom. (5) Direct right side operation. (6) Locking using RONIS ELAP lock (lock not included). 96 General Catalogue 2-24
10 NFC and DIN - Direct operation - 6 to 4 A Rating (A) Fuse size Frame size 6 A 6 A 4 25 A 5 4 A 2 6 No. of poles Direct side operation Direct front operation 2 P consult us 65 5 consult us consult us Direct handle (4)() Auxiliary contacts Terminal shrouds 2 P 9 26 () Cage terminals 54 6 Lock for fuse protection cover P consult us 9 6 () consult us consult us A-type contact NO/NC (2) 9 46 () P consult us A-type contacts 2 P consult us (4)() NO/NC () (2) consult us P consult us () consult us () consult us Handle key interlocking accessories (5) () Standard. (2) Maximum 2 contacts. () Top/bottom. (4) Direct right side operation. (5) Locking using RONIS ELAP lock (lock not included). NFC and DIN - Direct operation - 6 to 25 A Rating (A) Fuse size Frame size No. of poles Direct side and front operation Direct front handle Direct side handle Auxiliary contacts Terminal shrouds 6 A 7 8 A 7 8 A A P P P P ()(2) ()(2) U-type contact NO (4) contact NC (4) 2 P 8 28 () 8 8 () 8 48 () 2 P 8 22 () 8 2 () 8 42 () () Direct front operation. (2) Standard. () Top/bottom. (4) Maximum 8 contacts. General Catalogue
11 Accessories Direct operation handle For front operation Rating (A) Frame size Figure no. Handle colour Reference Red For right side operation Rating (A) Frame size Figure no. Handle colour Reference / acces_47_a_2_cat acces_262_a Fig. acces_48_a_2_cat acces_26_a Fig.2 fuser_77_a Fig. Fig.4 Fig. 5 External front operation handle Padlockable handle in position Rating (A) Frame Handle Handle Operation External IP size type colour Defeatable handle Reference CD 25 6 //2 S I - IP55 Yes 4 2 CD 25 6 //2 S I - Yes 4 2 CD 25 6 //2 S I - Yes 2 CD 25 6 //2 S I - - Test Yes 4 25 CD 25 6 //2 S I - - Test Yes 25 S type handle acces_49_a_2_cat acces_64_a_2_cat 4 6 S2 I - IP55 Yes S2 I - Yes S2 I - Yes S2 I - - Test IP55 Yes S2 I - - Test Yes handle S I - Yes S I - Yes S4 I - Yes S4 I - Yes 4 () IP: protection degree according to IEC 6529 standard. Padlockable handle in position and I Rating (A) Frame size Handle type Handle colour External IP () Reference CD 25 6 //2 S S () IP: protection degree according to IEC 6529 standard. S type handle acces_5_a_2_cat S4 type handle acces_52_a_2_cat External right side operation handle Rating (A) Frame size Handle type Handle colour External IP () Reference CD 25 6 //2 S IP CD 25 6 //2 S 47 2 CD 25 6 //2 S S2 IP S S /8 S /8 S 48 () IP: protection degree according to IEC 6529 standard. S type handle acces_49_a_2_cat acces_66_a_2_cat S type handle General Catalogue 2-24
12 External front operation handle with metal padlocking lever Rating (A) Frame size Handle type Handle External IP colour Defeatable handle Reference CD 25 6 //2 S Yes 4D 29 CD 25 6 //2 S Yes 4E S2 Yes 42D S2 Yes 42E S Yes 4D S Yes 4E S4 Yes D S4 Yes E 9 () IP: protection degree according to IEC 6529 standard. handle acces_26_a_2_cat acces_25_a_2_cat S type handle S-type handle adapter Use Enables S-type handles to be fitted in place of existing older style Socomec handles. Adapter can be utilised as a spacer to increase the distance between the panel door and the handle lever. Dimensions Adds 2 mm to the depth. Handle colour To be ordered in multiples of External IP () Reference 49 () IP: protection degree according to IEC 6529 standard. acces_87_a cat Alternative S-type handle cover colours Use For single lever handles S, S2, S types and double lever handle, S4 type. Other colours: please consult us. Handle colour To be ordered in multiples of Handle Reference Light grey 5 Type S, S2 4 Dark grey 5 Type S, S2 4 Light grey 5 S4 type 4 Dark grey 5 S4 type 4 4 acces a cat Flat mounting kit Use The flat mounting providing compact solution ideally suited to withdrawable applications. Kit to be used with a handle for flat mounting. Rating (A) Frame size Type Reference CD 25 CD 2 Kit + Shaft 2 mm Kit + Shaft 2 mm fuser_55_a cat Handle for flat mounting kit Padlockable handle in position Rating (A) Frame size Handle type Handle colour External IP () Reference CD 25 6 //2 S IP (2) CD 25 6 //2 S 2 (2) 4 6 S2 IP (2) 4 6 S (2) () IP: protection degree according to IEC 6529 standard. (2) Defeatable handle in position I. handle. fuser_56_a cat General Catalogue
13 Accessories (continued) Front operation shaft support accessory Use This support maintains shaft position for extension shafts greater than 2 mm in length. Rating (A) Frame size Reference Shaft guide for external operation Use To guide the shaft extension into the external handle. This accessory enables the handle to engage the extension shaft with a misalignment of up to 5 mm. Required for a shaft lengths over 2 mm. Description Reference Shaft guide 429 Shaft for external front operation handle Use Standard lengths: - 2 mm - 2 mm - 4 mm - 5 mm. Other lengths: consult us. Rating (A) Frame size Shaft length (mm) Reference CD 2 CD CD 2 CD CD 2 CD () acces_45_b cat acces_26_a_2_cat fuser_6_a_2_cat acces_69_a cat (2) / / () () Use the shaft guide accessory for external operation. (2) Use the front operation shaft support accessory. acces_22_a x_cat X Dimension X (mm) for FUSERBLOC BS88 CD 2 CD CD6 CD Shaft length (mm) A A A2-A/A4 A-A4 B-B2 B-B2-B C-C2-C D 2//4 A 4/5 5/ Dimension X (mm) for FUSERBLOC NFC and DIN CD 25 CD Shaft length (mm) x8/4x5 4x5 C 22x58/ / / General Catalogue 2-24
14 Shaft extensions for external side operation Use Standard lengths, 2 mm. Rating (A) Frame size Handle Dimension Shaft length type Y (mm) (mm) Reference CD 25 CD 2 S S /8 S acces_2_a x_cat Y Integrated solid link Use Fixing the solid onto the mechanism produces a device with a solid of the same size as a standard three-pole device (+ 6 mm). BS88 for external front operation Rating (A) Switch body Bar rating size (A) Reference CD 6 CD 2 a NFC and DIN For external front operation Rating (A) Frame size Bar rating (A) Reference acces a cat acces a cat Solid module BS88 for external front operation Switch body size Distance (mm) Rating (A) I max (A) Reference CD 6 CD 2 a NFC and DIN For external front operation Rating (A) Frame size I max (A) Distance (mm) Reference 5 / / / / / / acces_99_a_2_cat Solid links BS88 switches Rating (A) Frame size Fuse size I max (A) Reference 2 A A2-A A CD 6 a A-A A B-B CD 2 a A-A B-B B-B2-B B-B2-B B-B2-B-B C-C D NFC and DIN switches Rating (A) Frame size Fuse size I max (A) Reference 5 / 4 x /2 C / 22 x / / / / fusib_2_a_2_cat fusib_24_a_2_cat General Catalogue
15 Accessories (continued) A-type auxiliary contacts Use Pre-break and position and I signalling by or 2 NO /NC auxiliary contacts. For low level use, specific auxiliary contacts: please consult us. Connection to the control circuit By 6.5 mm fast-on terminal. Electrical characteristics operations. References NO / NC auxiliary contacts Rating (A) Frame size Contact(s) Reference CD 2 CD CD 2 CD () (2) 2 4 () (2) acces_46_a cat () Side direct operation switch only. (2) A type auxiliary contacts cannot be mounted in conjunction with integrated solid. Characteristics Operating current I e (A) Rating (A) Current nominal (A) 25 VAC 4 VAC 24 VDC 48 VDC AC- AC- DC- DC- CD acces_47_a_2_cat U-type auxiliary contacts () Use Compact universal type auxiliary contacts which can be configured for operation in either, or both, ON and TEST positions for CD 2 to 25 A FUSERBLOC. Each slot can accommodate up to two interlocked A/Cs. References NC auxiliary contacts Rating (A) Frame size Contact(s) Reference CD Connection to the control circuit By terminals with max. section 2 x 2.5 mm². For FUSERBLOC CD 2 to 4 A. Pre-break and signalling of positions, I and TEST. and I signalling. acces_56_a cat NO auxiliary contacts Rating (A) Frame size Contact(s) Reference CD Contact holder for auxiliary contacts Rating (A) Frame size Contact(s) Reference () CD (2 x 2 max) included /6 8 (4 x 2 max) included /8 8 (4 x 2 max) included () Cannot be mounted in direct operation. Contact holder for additional auxiliary contacts Rating (A) Frame size Contact(s) Reference CD 2 CD 2 4 (2 x 2 max) (2 x 2 max) Characteristics Operating current I e (A) 25 VAC 4 VAC 24 VDC 48 VDC Rating (A) AC-5 AC-5 DC- DC- CD A B acces_4_a x_cat () U-type auxiliary contacts cannot be mounted with an integrated solid. 22 General Catalogue 2-24
16 S and ST-type auxiliary contacts Use For FUSERBLOCs 2 to 25 A, position and I signalling by to 4 NO + NC auxiliary contacts. Electrical principle The NO + NC S-type auxiliary contacts can be configured as 2 NC or 2 NO. References S-type auxiliary contacts -I for external front and right-side operation (Standard operation) Rating (A) Frame size Contact type Reference NC+NO Connection By terminals with max. cross-section mm². Mechanical characteristics operations. acces_5_a_2_cat ST-type auxiliary contacts I--TEST for external front and right-side operation (TEST operation) Rating (A) Frame size Contact type Description Reference NC+NO TEST + ON O TEST + ON Characteristics Switch body for signalling auxiliary contact Contact type Operation type Reference S-type Standard 999 ST-type TEST 999 Operating current I e (A) Current Rating (A) 25 VAC 4 VAC nominal (A) AC- AC Fuse cover interlocking Use On NFC and DIN, side direct operation, locking of the opening of the fuse protection cover when FUSERBLOC is engaged (position I). Rating (A) Frame size Fuse size No. of poles Reference CD 2 5 x 8 / 4 x 5 2 / / 4 included 6 2 C 2 / / x 58 2 / / / / P P P Terminal shrouds Use Top or bottom IP2 protection (on the front) against direct contact with terminals or connection parts. Two sets required to fully shroud both incoming and outgoing terminals. Important: > For the 4 A rating, an adaptation kit reference 999 must be ordered in addition to the auxiliary contact kit. acces_8_a cat Rating (A) Frame size Position No. of poles Reference CD top / bottom 2 / / integrated CD 2 /4 top / bottom 2 P 9 26 CD 2 /4 top / bottom 9 6 CD 2 /4 top / bottom /6 top / bottom 2 P /6 top / bottom /6 top / bottom top / bottom 2 P top / bottom top / bottom top / bottom 2 P top / bottom top / bottom 8 42 fuser_4_a cat General Catalogue
17 Accessories (continued) NFC and DIN fuse blown indication Use For fuse cartridge with striker (size 4 x 5 22 x 58 ; ; ; 2 ; and 4). Electrical principle A NO/NC auxiliary contact detects that the fuse has blown. Connection to the control circuit 6.5 mm fast-on terminal. Mechanical characteristics operations. References NO/NC type auxiliary contacts for 2 pole Rating (A) Frame size Fuses Contact(s) Reference 5 4 x 5 st x 58 st st /6-2 st st st st NO/NC type auxiliary contacts for pole Rating (A) Frame size Fuses Contact(s) Reference CD 2 4 x 5 st x 5 st x 58 st st /6-2 st st st st nd nd NO/NC type auxiliary contacts for 4 pole or pole + Rating (A) Frame size Fuses Contact(s) Reference 5 4 x 5 st x 58 st st /6-2 st st st st nd nd Characteristics Rating (A) Operating current I Current e (A) 25 VAC 4 VAC 24 VDC 48 VDC nominal (A) AC- AC- DC- DC- CD Electronic fuse blown indication (FMD) Use Provides fuse blown indication with fuse links without fuse blown indication strikers. Suitable for use with BS88, DIN and UL type fuses. References For FUSERBLOC 6 to 25A - size to 4 Nb of LEDs Operating voltage Reference (FMD) 2-26 VDC (FMD) 8-69 VDC (FMD) 2-26 VDC (FMD) 8-69 VDC Accessories Reference Kit for connection accessories Standard Kit for connection accessories Door mounted Principle The Fuse Melting Device (FMD) detects the operation of a fuse and provides a signal via: a relay and LED (FMD) or a bi-stable relay and LEDs (FMD). The FMD can be DIN rail or back plate mounted close to the Fuserbloc, directly mounted on the FUSERBLOC, or it can be door mounted to provide information directly on the front of a panel. DDMM for cylindrical fuses DDMM for NH fuses acces_9_a acces a fuser_2_a cat fuser a cat Relay characteristics Relay operating current I Rating (A) c (A) AC-5 DC A.2 LED version (FMD) LED version (FMD) 24 General Catalogue 2-24
18 Cage terminals Use Connection of bare copper cables onto the terminals (without lugs). References Rating max (A) Frame size No. of poles Reference CD / / integrated 6 / / acces_5_a cat Connections Rating (A) Flexible cable cross-section (mm 2 ) Rigid cable cross-section (mm²) Flexible bar width (mm) Stripped over (mm) X Dimensions Rating (A) A A C R ØX X Z M M M2 5 øx Z A acces_9_a x_cat C A R acces_92_a x_cat Handle key interlocking accessories Use Locking in position of the direct, front or right side operation: - using a padlock (not supplied) in direct right side operation: integrated into the handle, - using a padlock (not supplied): right-side or front operation switch from 2 to 25 A, factory integrated - using a padlock (not supplied) in external operation. Locking using RONIS EL AP lock (not supplied) Rating (A) Frame size Operation Figure n Reference CD external front /2 direct direct direct Locking using K-type CASTELL lock (not supplied) Rating (A) Frame size Operation Figure n Reference CD external front Fig. acces_42_a x_cat Locking using FS-type CASTELL lock (not supplied) Rating (A) Frame size Operation Figure n Reference CD external front Locking using XOP (not supplied) Rating (A) Frame size Operation Reference CD external front Fig.2 acces_58_a x_cat Fig. acces_57_a x_cat Label holder Use Recognisable self-adhesive label allowing identification of the devices. Dimensions W x H (mm) To be ordered in multiples of Reference 8 x acces a cat General Catalogue
19 Characteristics according to IEC to A Thermal current I th (4 C) 2 A 25 A CD 2 A CD 2 A 2 A 5 A 6 A A BS88/DIN fuse size A/- -/ x 8 -/ x 8 A/4 x 5 A/- -/4 x 5 A2-A/C A4*/22 x 58 Frame size for direct operation 2 Switch body size for front and side operation 2 Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated operational currents Ie (A) Rated voltage Utilisation category A/B () A/B () A/B () A/B () A/B () A/B () A/B () A/B () 4 VAC AC-22 A / AC-22 B 2/2 25/25 2/2 2/2 2/2 5/5 6/6 / 4 VAC AC-2 A / AC-2 B 2/2 25/25 2/2 2/2 2/2 5/5 6/6 / 69 VAC AC-22 A / AC-22 B 2/2 25/25 2/2 2/2 2/2 5/5 6/6 (4)/ (4) 69 VAC AC-2 A / AC-2 B 2/2 25/25 2/2 2/2 2/2 5/5 6/6 (4)/ (4) 22 VDC DC-2 A / DC-2 B -/2 2/2 5/5 6/6 / 22 VDC DC-2 A / DC-2 B -/25 (2) 2/2 4/4 4/4 / VDC DC-2 A / DC-2 B 2 () /2 () 5 () /5 () 6 () /6 () () / () VDC DC-2 A / DC-2 B 2 () /2 () 4 () /4 () 4 () /4 () () / () Operational power in AC-2 (kw) At 4 VAC without pre-break in AC ()(5) 9/9 / 5/5 5/5 5/5 25/25 / 5/5 At 69 VAC without pre-break in AC ()(5) 5/5 22/22 25/25 25/25 25/25 45/45 55/55 9/9 Reactive power (kvar) At 4 VAC (5) Fuse protected short-circuit withstand BS88/DIN (ka rms prospective) Prospective short-circuit (ka rms) (6) 8/- -/ -/ 8/ 8/ -/ 8/ 8/ Associated fuse rating (A) (6) 2/- -/25 -/2 2/2 2/2 -/5 6/6 / Short-circuit capacity Rated peak withstand current (ka peak) (6) Fuse selection (maximum fuse size) (7) SOCOMEC BS88 6A A 2 6A 2 6A 6 6A4 SOCOMEC BS88 6AM AM 6 6AM 2 6AM 8 6A4M 25 SOCOMEC DIN SOCOMEC DIN BUSSMANN NITD 2 NITD 2 NITD 2 BAO 6 CEO BUSSMANN NITD 2M2 NITD 2M6 NITD 2M6 BAO 6M8 CEO M25 LAWSON NIT 2 NIT 2 NIT 2 TIS 6 TCP LAWSON NIT 2M2 NIT 2M2 TIS 6M8 CTFP M25 GE NIT 2 NET 2 NET 2 TIS 6 TCP GE NIT 2M2 NET 2M6 NET 2M6 TIS 6M8 OCP M25 Connection Minimum Cu cable cross-section (mm 2 ) Maximum Cu cable cross-section (mm 2 ) Maximum busbar width (mm) 2 Min. / Max. tightening torque min (Nm) 2/- 2/- 2/ 2 2.5/ 2.5/ 2.5/ 8./ Mechanical characteristics Durability (number of operating cycles) Weight of switch (kg) Weight of switch (kg) Weight of P extra (kg) Frame pitch (mm) () Category with index A = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or terminal screen. () 4-pole device with 2 pole in series by polarity. (4) Poles cannot be juxtaposed. (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) For a rated operational voltage Ue = 4 VAC. (7) Fuse 8 A, 69 VAC does not exist, tests conducted with bars. * For fuse size A4: max diameter mm. ** Please ensure that fuse let through current does not exceed short-circuit capacity of the switch (ka peak). 26 General Catalogue 2-24
20 25 to 2 A Thermal current I th (4 C) 25 A 25 A 6 A CD 6 A 6 A 6 A CD 2 A 2 A NFC/DIN fuse size -/22 x 58 -/ -/ A-A4*/- A4/ B-B2/- A-A4*/- B-B2/- Frame size for direct operation Switch body size for front and side operation A 4 4 A 5 Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated operational currents Ie (A) Rated voltage Utilisation category A/B () A/B () A/B () A/B () A/B () A/B () A/B () A/B () 4 VAC AC-22 A / AC-22 B 25/25 25/25 6/6 6/6 6/6 6/6 2/2 2/2 4 VAC AC-2 A / AC-2 B 25/25 25/25 6/6 6/6 6/6 6/6 2/2 2/2 69 VAC AC-22 A / AC-22 B 25 (2)/ 25 (2) 25 (2)/ 25 (2) 6 (2)/ 6 (2) 6 (2/ (2) 6 6(2)/6(2) 6(2)/6(2) 6(2)/6(2) 2(2)/2(2) 69 VAC AC-2 A / AC-2 B (2)/ (2) (2)/ (2) 25 (2)/ 25 (2) 25 (2)/ 25 (2) 25 (2)/ 25 (2) 25 (2)/ 25 (2) 25 (2)/ (2) 25 2(2)/6(2) 22 VDC DC-2 A / DC-2 B 25/25 25/25 6/6 6/6 6/6 6/6 6/6 2/2 22 VDC DC-2 A / DC-2 B / / 25/25 25/25 25/25 25/25 25/25 2/2 VDC DC-22 A / DC-22 B 25 () /25 () 25 () /25 () 6 ()/ 6 () 6 ()/ 6 () 6 ()/ 6 () 6 ()/ 6 () 6 ()/ () 6 2()/2() VDC DC-2 A / DC-2 B ()/ () ()/ () 25 ()/ 25 () 6 ()/ 6 () 25 ()/ 25 () 25 ()/ 25 () 25 ()/ () 25 2()/2() Operational power in AC-2 (kw) At 4 VAC without pre-break in AC ()(5) 6/6 6/6 8/8 8/8 8/8 8/8 8/8 / At 69 VAC without pre-break in AC ()(5) 9/9 9/9 / / / / / 5/85 Reactive power (kvar) At 4 VAC (5) Fuse protected short-circuit withstand (ka rms prospective) Prospective short-circuit (ka rms) (6) -/ -/ -/ (5) 5/- 8/ 8/ 5/- 8/- Associated fuse rating (A) (6) -/25 -/25 -/25 (6) 6/- 6/6 6/6 2/- 2/- Short-circuit capacity Rated peak withstand current (ka peak) (6) Fuse selection (maximum fuse size) (7) SOCOMEC BS88 6A4 6 6A4 6 6B2 6 6A4 2 6B2 2 SOCOMEC BS88 6A4M 6 6A4M 6 6BM 2 6A4M 5 6B2M 5 SOCOMEC DIN SOCOMEC DIN BUSSMANN DEO 6 DEO 6 DD 6 DEO 2 DD 2 BUSSMANN CEO M6 DEO M2 CD M2 DEO 2M5 DD 2M5 LAWSON CTFP 6 TFP 6 TF 6 TF 2 TF 2 LAWSON CTCP M6 TCP M2 TCP M2 TC 2M5 TC 2M5 GE TCP TFP 6 TF 6 TF 2 TF 2 GE OCP M6 TCP M2 TC M2 TF 2M5 TF 2M5 Connection Minimum Cu cable cross-section (mm 2 ) Maximum Cu cable cross-section (mm 2 ) Maximum busbar width (mm) Tightening torque min (Nm) 8./ 8./ 8./ 8./ 8./ 8./ 8./ 2/26 Mechanical characteristics Durability (number of operating cycles) Weight of switch (kg) Weight of switch (kg) Weight of P extra (kg) Frame pitch (mm) () Category with index A = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or phase barrier. () Poles cannot be juxtaposed. (4) 4-pole device with 2 poles in series per polarity. (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) For a rated operational voltage Ue = 4 VAC. (7) Fuse 8 A, 69 Vac does not exist, tests conducted with bars. General Catalogue
21 Characteristics according to IEC (continued) 25 to 25 A Thermal current I th (4 C) 25 A 5 A 4 A 6 A 8 A 8 A 25 A NFC/DIN fuse size B-B2-B/ B-B2-B/- B-B2-B-B4/2 C-C2/ C-C2-C/ -/4 D/4 Frame size for direct operation Switch body size for front and side operation Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Rated operational currents Ie (A) Rated voltage Utilisation category A/B () A/B () A/B () A/B () A/B () A/B () A/B () 4 VAC AC-22 A / AC-22 B 25/25 5/5 4/4 6/6 8/8 8/8 25/25 4 VAC AC-2 A / AC-2 B 25/25 5/5 4/4 6/6 8/8 8/8 /25 69 VAC AC-22 A / AC-22 B 25 (2)/ 25 (2) 5 (2) /5 (2) 4/4 5/6 8/8 8/8 (7) 8/25 69 VAC AC-2 A / AC-2 B 25 (2)/ 25 (2) 25 (2)/ 5 (2) 4/4 5/4 6/6 8/8 (7) 8/6 22 VDC DC-2 A / DC-2 B 25/25 25/25 5/5 5/6 8/8 8/8 25/25 22 VDC DC-2 A / DC-2 B 2/2 2/2 2/5 4/6 8/8 8/8 25/25 VDC DC-22 A / DC-22 B 25 () / 25 () 25 () / 25 () 5 (4)/ 5 (4) 5/6 (4) 8 () / 8 () 8/8 () / () VDC DC-2 A / DC-2 B 2 () / 2 () 2 () / 2 () 25 (4) / 5 (4) 4 (4) /6 (4) 8 () / 8 () 8 / 8 () () / () Operational power in AC-2 (kw) At 4 VAC without pre-break in AC ()(5) 2/2 6/6 22/22 55/55 45/45 45/45 56/56 At 69 VAC without pre-break in AC ()(5) 22/22 22/295 22/ /4 4/4 4/4 4/475 Reactive power (kvar) At 4 VAC (5) Fuse protected short-circuit withstand (ka rms prospective) Prospective short-circuit (ka rms) (6) 8/ 8/- 8/5 8/ 8/ -/ -/ Associated fuse rating (A) (6) 25/25 5/- 4/4 6/6 8/8 -/8 -/25 Short-circuit capacity Rated peak withstand current (ka peak) (6) Fuse selection (maximum fuse size) (7) SOCOMEC BS88 6B2 25 6B 5 6B4 4 6C2 6 6C 8 SOCOMEC BS88 6B2M 5 6BM 4 6B4M 5 SOCOMEC DIN SOCOMEC DIN BUSSMANN ED 25 ED 5 ED 4 FF 6 GF 8 BUSSMANN DD 2M5 ED 5M4 ED 4M5 LAWSON TKF 25 TKF 5 TMF 4 TTM 6 TLM 8 LAWSON TF 2M5 TKF 5M4 TMF 4M5 GE TKF 25 TKF 5 TMF 4 TTM 6 TLM 8 GE TF 2M5 TKF 5M55 TMF 4M45 Connection Minimum Cu cable cross-section (mm 2 ) x 5 2 x 85 Maximum Cu cable cross-section (mm 2 ) x 2 x 4 x 85 4 x 85 Maximum busbar width (mm) Tightening torque min (Nm) 2/26 2/26 2/26 4/45 4/45 4/45 4/45 Mechanical characteristics Durability (number of operating cycles) Weight of switch (kg) Weight of switch (kg) Weight of P extra (kg)... Frame pitch (mm) () Category with index A = frequent operation - Category with index B = infrequent operation. (2) With terminal shrouds or terminal screen. () 4-pole device with 2 pole in series by polarity. (4) Poles cannot be juxtaposed. (5) The power value is given for information only, the current values vary from one manufacturer to another. (6) For a rated operational voltage Ue = 4 VAC. (7) Fuse 8 A, 69 VAC does not exist, tests conducted with bars. ** Please ensure that fuse let through current does not exceed short-circuit capacity of the switch (ka peak). 28 General Catalogue 2-24
22 External operation BS88 - FUSERBLOC CD 2 to CD 2 A in size A External front operation 2 min vfuser_292_d x_cat. With U-type AC: mm With 2 U-type AC: 55 mm. External side operation min min fuser_295_c x_cat External front operation fuse combination changeover 5 min fuser b x_cat. With U-type AC: mm With 2 U-type AC: 55 mm. General Catalogue
23 External operation NFC and DIN - FUSERBLOC 25 to 2 A in size x 8 External front operation External side operation 2 min mini 96 6 mini With U-type AC: mm. With 2 U-type AC: 55 mm fuser_29_d x_cat fuser_294_c x_cat NFC and DIN - FUSERBLOC 2 A in size 4 x 5 External front operation External side operation 2 min min min fuser_292_d x_cat fuser_295_c x_cat. With U-type AC: mm. With 2 U-type AC: 55 mm. NFC and DIN - FUSERBLOC 25 to 2 A in size x 8 and 4 x 5 External front operation fuse combination changeover 5 min fuser b x_cat 8. With U-type AC: mm. With 2 U-type AC: 55 mm. 2 General Catalogue 2-24
24 External front or right side operation BS88 - FUSERBLOC 2 A in fuse size A NFC and DIN - FUSERBLOC 5 A in fuse size 4 x 5 *fix min 5 max Z Y Ø6.2 2 (P) 48 (4P) min + N x 2.5* max 45 + N x 2.5* 2.5* W fix fuser_624_b x_cat 4 X fix 6 *fix * to use if pre-break auxiliary contact number > 4 W: 84.5 for BS88; 87 for NFC and DIN X: 5 only for DIN Y: 85 only for DIN Z: 26 only for DIN Dimensions for external operation handles. S-type auxiliary contact NO + NC to use if block number > 4 2. Rear connection (option). or 2 pre-break auxiliary contact (fuse blown indication) 4. to 4 pre-break auxiliary contact for signalisation 5. Additional contact holder for U-type AC BS88 - FUSERBLOC 2 to 6 A - NFC and DIN - FUSERBLOC 25 to 6 A Handle type Front operation Direction of operation Door drilling Side operation Direction of operation Door drilling fuser_72_a gb_cat S type Box size Ø.7 Ø TEST 65 9 I Ø.46 Ø 7 4 Ø.27 4 Ø I 4 Ø.27 4 Ø Ø.46 Ø General Catalogue
25 External front or right side operation BS88 - FUSERBLOC 6 A in fuse size A2 - A NFC and DIN - FUSERBLOC 6 A in fuse size C *fix min 5 max Ø min W max X (P) 68 (4P) fix fix 6 *fix fuser_625_b x_cat Y Z * to use if pre-break auxiliary contact number > 4 W: 24 + N x 2.5 for BS88; 9 for NFC and DIN X: 45 + N x 2.5 for BS88; 45 for NFC and DIN Y: 59 only for DIN Z: 45 only for DIN. S-type auxiliary contact NO + NC to use if block number > 4 2. Rear connection (option). to 4 pre-break auxiliary contact for signalisation 4. Additional contact holder for U-type AC 22 General Catalogue 2-24
26 BS88 - FUSERBLOC A in fuse size A4 - max Ø mm NFC and DIN - FUSERBLOC to 25 A in fuse size 22 x 58 - FUSERBLOC 25 to 6 A in fuse size * fix min 5 max (P) 84 (4P) Ø8.7 min 9 max fix fix fix 52.5* fuser_626_a x_cat Ø8.5 5 X * to use if pre-break auxiliary contact number > 4 X: 79 for BS88 / NFC and DIN to 25 A 89 for NFC and DIN 25 to 6 A. S-type auxiliary contact NO + NC to use if block number > 4 2. Rear connection (option). to 4 pre-break auxiliary contact for signalisation 4. or 2 pre-break auxiliary contact (fuse blown indication) 5. Terminal shrouds 6. Additional contact holder for U-type AC General Catalogue
27 External front or right side operation BS88 - FUSERBLOC CD 6 to CD 2 A in fuse size A-A4 (A4 max Ø mm) *fix. 5.5 B min 5 max (P) 84 (4P) Ø8.7 min 45 max fix fuser_627_b x_cat fix fix. 52.5* Ø * to use if pre-break auxiliary contact number > 4. S-type auxiliary contact NO + NC to use if block number > 4 2. Rear connection (option). to 4 pre-break auxiliary contact for signalisation 4. Terminal shrouds 5. Additional contact holder for U-type AC 24 General Catalogue 2-24
28 BS88 - FUSERBLOC 6 A in fuse size A4 & B-B2 NFC and DIN - FUSERBLOC 6 A in fuse size *fix min 5 max Ø8.7 min 45 max fix fix fix 52.5* (P) 24 (4P) 4 fuser_628_b x_cat 5 74 Ø8.5 2 * to use if pre-break auxiliary contact number > 4. S-type auxiliary contact NO + NC to use if block number > 4 2. Rear connection (option). to 4 pre-break auxiliary contact for signalisation 4. or 2 pre-break auxiliary contact (fuse blown indication) 5. Terminal shrouds 6. Additional contact holder for U-type AC General Catalogue
29 External front or right side operation BS88 - FUSERBLOC 2 A in fuse size B-B2 FUSERBLOC 25 A in fuse size B-B2-B NFC and DIN - FUSERBLOC 25 A in fuse size *fix min 5 max fix *fix Ø 24 (P) 294 (4P) min 54 max fix 6 P 86 4P fuser_629_b x_cat 5 85 Ø * to use if pre-break auxiliary contact number > 4. S-type auxiliary contact NO + NC to use if block number > 4 2. Rear connection (option). to 8 pre-break auxiliary contact for signalisation 4. or 2 pre-break auxiliary contact (fuse blown indication) 5. Terminal shrouds 6. Additional contact holder for U-type AC 26 General Catalogue 2-24
30 BS88 - FUSERBLOC 5 A in fuse size B-B2-B FUSERBLOC 4 A in fuse size B-B2-B-B4 NFC and DIN - FUSERBLOC 4 A in fuse size 2 *fix min 5 max 2 * to use if pre-break auxiliary contact number > 4. S-type auxiliary contact NO + NC to use if block number > 4 2. Rear connection (option). to 8 pre-break auxiliary contact for signalisation4. or 2 pre-break auxiliary contact (fuse blown indication) 5. Terminal shrouds 6. Additional contact holder for U-type AC Ø (P) 8 (4P) min 57 max fix fix *fix fuser_6_b cat 5 Ø Dimensions for external operation handles BS88 / NFC and DIN - FUSERBLOC to 4 A Handle type Front operation Direction of operation Door drilling Side operation Direction of operation Door drilling Box size -6 Ø.7 Ø TEST 65 9 I Ø.46 Ø Ø.27 4 Ø I 4 Ø.27 4 Ø Ø.46 Ø fuser_7_a gb_cat General Catalogue
31 BS88 - External front operation fuse combination changeover FUSERBLOC 2 to 4 A F A E min. J J fuser_64_e x_cat H 4 DA 2 BA N 8.2 AA AC 2 W DB Y Z U T T T T A. S handle: 2 and 6 A B. S handle: to 4 A C. Door drilling. Fuse blown indicaion not available for BS88 2. Terminal shrouds Rating (A) Fuse size Frame size A P Dimensions A 4 P E min E max Terminal shrouds AC F P F 4 P H Switch body J P J 4 P J J Switch mounting Connection DA DB N T U W Y Z AA BA 2 A () 46 () A2-A A (2) CD 6 A-A4 A A B-B CD 2 A-A4 A B-B B-B2-B B-B2-B B-B2-B-B () AC: mm / 2 AC: + 47 mm. (2) 2 mm with 2 AC. 28 General Catalogue 2-24
32 NFC and DIN - External front operation fuse combination changeover FUSERBLOC 5 to 4 A F A E min. J J fuser_64_e x_cat H 4 DA 2 BA N 8.2 AA AC 2 W DB Y Z U T T T T A. S handle: 5 and 6 A B. S2 handle: to 4 A C. Door drilling. Fuse blown indicaion not available for BS88 2. Terminal shrouds Rating (A) Fuse size Frame size Overall dimensions A p A 4p E min E max Terminal shrouds AC F F H Switch body J J J J Switch mounting Connection DA DB N T U W Y Z AA BA 4 x () 46 () () C (2) x (2) x (2) () AC: +2.5 / 2 AC: +47 (2) 2 with 2 AC General Catalogue
33 BS88 - Direct operation FUSERBLOC CD 2 to CD 2 A in frame size / fuse size A fuser_48_c x_cat FUSERBLOC 2 to 4 A 2 H S AD R T J 7 BA N AA AC Y DA fuser_64_b x_cat C Z W U AB T DB A. Protection screen lockable in position I 2. or 2 fuse blown indication.. or 2 A type ACs Rating (A) Fuse size Frame size Dimensions Terminal shrouds Switch body Switch mounting Connection A A 4 C AB AB AC AD H J DA DB N R S T U W Y Z AA BA 2 A A2-A A CD 6 A-A4 A A B-B CD 2 A-A4 A B-B B-B2-B B-B2-B B-B2-B-B General Catalogue 2-24
34 NFC and DIN - Direct operation FUSERBLOC 25 to 2 A in frame size / fuse size x 8 FUSERBLOC 2 A in frame size / fuse size 4 x fuser_8_c x_cat FUSERBLOC 5 to 4 A 2 H S AD R T J 7 BA N AA AC fuser_48_c x_cat Y DA Z W fuser_64_b x_cat DB C U AB T A. Protection screen lockable in position I 2. or 2 fuse blown indication.. or 2 A type ACs Rating (A) Fuse size Frame size Overall dimensions Terminal shrouds Switch body Switch mounting Connection A A C AB AB AC AD H J DA DB N R S T U W Y Z AA BA 5 4 x C x x General Catalogue
35 Direct and external front or right side operation BS88 - FUSERBLOC 6 A in fuse size C-C2 FUSERBLOC 8 A in fuse size C-C2-C NFC and DIN - FUSERBLOC 6 to 8 A in fuse size min min (P) 458 (4P) 2 46 Fix 284 (P) Fix 78 (4P) 65 4 min 5 fuser_6_b fix 25 Ø Direct operation 2. S-type auxiliary contact NO + NC. Rear connection (option) 4. to 8 pre-break auxiliary contact for signalisation 5. Terminal shrouds Dimensions for external operation handles FUSERBLOC 6 to 8 A Handle type S type Box size 7 Ø.7 Ø78 fuser_74_a gb_cat 6 2 Direction of operation Front operation 9 I Ø.46 Ø 7 Door drilling Ø.27 4 Ø Side operation Direction of operation Door drilling 9 I 4 Ø.27 4 Ø Ø.46 Ø General Catalogue 2-24
36 BS88 - FUSERBLOC 25 A in fuse size D NFC and DIN - FUSERBLOC 8 to 25 A in fuse size 4. Direct operation 2. S-type auxiliary contact NO + NC. Rear connection (option) 4. to 8 pre-break auxiliary contact for signalisation 5. Terminal shrouds min (P) 562 (4P) 46 min 5 min fix 62 (P) fix 482 (4P) fix 25 fuser_62_b x_cat FUSERBLOC 8 to 25 A Handle type Front operation Direction of operation Side operation Direction of operation Door drilling S type Box size 8 Ø.7 Ø78 9 I 2 4 Ø 7 Ø 7 S4 type Ø I fuser_75_a gb_cat 6 General Catalogue
FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are
More informationFUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A
Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More information125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request
125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for
More informationSIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.
Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity
More informationSIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC
and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar
More informationSIRCO M and MV Universal load break switches from 16 to 160 A
SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV
More informationAn innovative technology
The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions
to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They
More informationSIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points
Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity
More informationWhat you need to know. Â Conformity to standards
SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational
More informationSIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A
Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationLoad break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...
Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch
More informationATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A
Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to
More informationSIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC
Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics
More informationSIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC
Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar
More informationSIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC
Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty
More informationSIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC
SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A
TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS
More informationfor NH industrial and high-speed (ur) fuses from 160 to 2500 A
for NH industrial and high-speed (ur) fuses from 60 to 00 socle_066_b cat socle_046_b cat The solution for > Motor feeders > Protection of industrial cabinet Function ase Size ase IPX SOOME fuse bases
More informationIntegrated products & solutions
2017 2018 CATALOGUE EXTRACT Integrated products & solutions Enclosed switching, protection and metering systems Contents An independent manufacturer................................................. Expert
More informationsirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed
site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on
More informationCATALOGUE MARINE APPLICATIONS. Energy performance solutions
CATALOGUE MARINE APPLICATIONS Energy performance solutions 2017 2018 Marine Certifications Our certified products As an independent manufacturer, we, at Socomec are committed to adapting the range and
More informationnew NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price
NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high
More informationIP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.
General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More informationSwitch disconnectors
Selection Load break switch disconnectors type LK3, 40-120 A Selection guide for 3 and 4-pole switch disconnectors General The LK3 range of switch disconnectors (lth: 40 A to 120 A) is designed for use
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationSIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A
Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat
More informationSafety enclosures. 482 General Catalogue SOCOMEC. Safety enclosures
coff_163_a_1_cat coff_156_b_1_cat Function equipped with SOCOMEC switches provide emergency breaking, breaking for mechanical maintenance and safety isolation in the vicinity of any low voltage final circuit.
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationTeSys GS & DF Fuse protection
TeSys GS & DF Fuse protection Simple and effective protection TeSys GS Fuse disconnect switches Total isolation between poles Safe replacement of the fuses (double breaking system) Frontal and right side
More informationMotorised and automatic transfer enclosed switchess
s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >
More informationFuse Combination Units
Fuse Combination Units Loadswitch Range Fuse Combination Units (16-800A) O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E Dorman Smith Switchgear Ltd With over 130 years of experience
More informationSafety enclosures Normal atmospheres steel enclosure from 50 to 1600 A
Integrated products & solutions The solution for > Iron and steel industry > Cement plants > Paper mills > Sawmills > Hydraulic power packs > Automotive > Mining coff_436_a coff_434_a Strong points Function
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationLoadswitch. Fuse Combination Units
Loadswitch Dorman Smith Switchgear Limited With over 130 years of experience in switchgear design and production Dorman Smith Switchgear Limited continues to provide high quality equipment for lowvoltage
More informationPANEL PANEL MOUNTING COMPONENTS
PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology
More informationSwitching, control and protection solutions for solar applications
Switching, control and protection solutions for solar applications continuous performance www.socomec.com Summary SIRCO M PV Manually operated modulable and modular switches p. 4 SIRCO MV PV Manually
More informationMANUALLY OPERATED CHANGEOVER SWITCHES
are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationFUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems
FUSERBLOC CD The universal Fuse Combination Switch FROM 20 TO 1250 A SOCOMEC GROUP SWITCHING PROTECTION & UPS Industrial Switching & Protection Systems SWITCHING FUSERBLOC CD THE UNIVERSAL FUSE COMBINATION
More informationTHE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions
THE SANTON FCS-TYPE SWITCH DISCONNECT Superior Switch Solutions The technical information given in this table applies to and pole fuse combination switches. A B NOMINAL RATING 0A A FUSE COMBINATION SWITCHES
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions
More informationCATALOGUE. Solutions for Power, Control & Safety
CATALOGUE Solutions for Power, Control & Safety 2015 Contents An independent manufacturer... p.4 Four key applications: the benefit of a specialist... p. 5 A cutting-edge laboratory... p. 6 Socomec in
More information25A 25A 32A 40A 40A 63A 63A 80A
ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A
More informationSIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A
2017 CTLOGUE extract SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200 Transfer switches svr_207_a.eps svr_208_a.eps The solution for > Manufacturing > Power
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationGeneral Characteristics
from 63 to 31 lbs_037_a he solution for > ain switchboard > Distribution panel > Emergency switching > us tie Function he CEC ensures making and breaking on load and security breaking of any low voltage
More informationMOULDED CASE CIRCUIT BREAKERS BC160N
D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationPhotovoltaic fuses gpv curve from 1 to 600 A, up to 1500 VDC
from to 600 A, up to 500 VDC Fuse protection The solution for > Photovoltaic protection fusib_03_a cat fusib_026_a cat Function fusib_030_a x_cat fusibpv_06_a cat SOCOMEC's gpv fuses protect photovoltaic
More informationMS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories
Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10
More informationTeSys GS. Data for Designers. Contents
TeSys GS Technical Data for Designers Contents Characteristics: > switch-disconnector... B5/16 to B5/21 > auxiliary contacts...b5/22 Dimensions... B5/23 to B5/31 Schemes...B5/31 B5/15 Characteristics -
More informationLOAD BREAK SWITCHES AND SWITCH FUSES
easy to install LOAD BREAK SWITCHES AND SWITCH FUSES Sixty years of innovation in developing and producing high-quality switches When Mr Kauko Hyryläinen founded KATKO in 1941, one of his key targets
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationvertical fuse switch disconnectors
SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -
More informationUltraSafe US22 Modular fuse-holders
UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards
More informationCATALOG. EasyLine XLP Fuse Switch Disconnector poles
CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction
More informationSFS-UFS Single Foot Switches
SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes
More informationProduct brochure. ABB Fusegear EasyLine Fuse switch disconnector
Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse
More information3NP1 Fuse Switch Disconnectors up to 630 A
Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors
More informationA compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.
PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationSwitches disconnectors with fuse-holders. XNF series TF series
Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary
More informationFUSIBLE DISCONNECT SWITCHES
FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationModulostar US10 Modular fuse-holders
Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationSwitches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference
Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationFuse switch disconnectors
SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY
More informationSwitch Disconnectors
Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationAutomatic COSYS PFC. Automatic power factor correction system NEW
Automatic COSYS PFC Automatic power factor correction system NEW cosys_178_a_1_x_cat cosys_178_a_1_x_cat appli_xxx_a  Function Your reactive energy consumption vary depending on the type and using conditions
More informationModulostar CMS10 Modular fuse-holders
Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC
More informationTransfer switching solutions
CATALOGUE EXTRACT Transfer switching solutions from 40 to 6300 A 2018 Contents The SOCOMEC Group... Security and reliability for your transfer applications... Remotely operated and Automatic Transfer
More informationPractical and completely safe
FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationGeneral information about motor protection
Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch
More informationNH-Fuse system Low voltage
38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories
More informationFuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A
www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse
More information