SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

Size: px
Start display at page:

Download "SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC"

Transcription

1 Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty switches that break and make DC photovoltaic circuits on and off load. They are suitable for use in accordance with NEC rt. 690 Photovoltaic Installations. These switches are extremely durable and are tested and approved for use in the most demanding applications. dvantages Optimise your investment High switching performances means less poles in series to reach the operating voltage, consequently: Less bridging bars required, limiting installation costs and time. Less heat dissipation, making it possible to be installed in a smaller enclosure. Guarantee safety over time SIRCO PV are extremely robust products, with all casings made from fiber glass reinforced polyester materials that allows: High mechanical withstand. High stability to temperatures (RTI of 30 C). High dielectric performance (high CTI / tested according to STM D 2303). They are available in 2, 3, 4, 6 and 8 poles for all configurations from one to 4 circuits and can be used in all types of earthing systems (floating or grounded systems, single or double switching), in order to suit all your requirements. Take advantage of an innovative design The SIRCO PV are able to operate on and off load up to 500 VDC per poles, providing extremely compact solution: 000 VDC (UL 98) on a 2 poles switch. 500 VDC (IEC ) on a 3 poles switch. Up to 4 circuits each at 000 VDC on an 8 poles switch. Reliability and performance Our range of SIRCO PV load break switches is compliant with UL98 and IEC standards and have been tested above standards expectation, ensuring no critical current. They are as well able to withstand 0 k, 50 ms, allowing the use of any overcurrent protection device for line protection. Strong points > Patented switching technology > Positive break indication > Up to 000 VDC as per UL98 > Up to 500 VDC as per IEC > Suitable for use in accordance with NEC rt. 690 Conformity to standards > UL98 Guide WHV, file E34648 > CS C22.2#4, Class 46502, file 2964 > NEC rt 690 > IEC pprovals and certifications () () Product reference on request. 58 Catalogue 204

2 Typical PV architecture The SIRCO PV range provides safe disconnection and isolation at all levels of your PV installation. SIRCOPV 054 The SOCOMEC solutions Combiner box LEVEL OF INSTLLTION SOCOMEC SOLUTIONS SIRCO PV One circuit up to 500 at 500 VDC Recombiner box SIRCO PV 4 circuits up to 500 at 000 VDC 2 circuits up to 500 at 500 VDC Inverter SIRCO PV One circuit up to 2000 at 000 VDC up to 2000 at 500 VDC Catalogue

3 References 000 VDC ack plate mounting Rating () No. of poles Switch body External handle PV circuit S2 type PV 2009 lack, 3R, 2 42F 2 () PV 209 Red/Yellow, 3R, P 27PV G 2 () PV PV PV P DC DC DS 8 P 27DC DS 2 PV circuits 27PV DS 27PV PV P PV DS 27PV DS 8 P 27DC DS 27DC 80 lack 42D 2 () Red/Yellow 42E 2 () S3 type lack 43D 3 () Red/Yellow 43E 3 () S4 type lack 44D 3 () Red/Yellow 44E 3 () V type lack 3R, S2 type lack, 3R, 2 42F 2 () Red/Yellow, 3R, 2 42G 2 () lack 42D 2 () Red/Yellow 42E 2 () V type lack 3R, Shaft for external handle 200 mm 7.9 inches mm 2.6 inches mm 5.7 inches (2) 200 mm 7.9 inches mm 2.6 inches mm 5.7 inches (2) 320 mm 2.6 inches mm 7.9 inches mm 2.6 inches mm 5.7 inches (2) 320 mm 2.6 inches ridging bar x x x x x x x x x x (2 units) 4x x PV circuits DS 8 P 27PV 8039 S3 type lack 43D 3 () Red/Yellow 43E 3 () 200 mm 7.9 inches mm 2.6 inches mm 5.7 inches (2) 4x () Defeatable handle. (2) Shaft guide reference is required for shaft length over 5.7 inches (400mm). 60 Catalogue 204

4 500 VDC ack plate mounting Due to UL98 voltage limitation at 000 VDC, these switches are certified per UL at 000 VDC and selfcertified at 500 VDC. Rating () No. of poles Switch body External handle PV circuit Shaft for external handle ridging bar PV P 27PV PV 3039 S2 type lack, 3R, 2 42F 2 () Red/Yellow, 3R, 2 42G 2 () lack 42D 2 () Red/Yellow 42E 2 () 200 mm 7.9 inches mm 2.6 inches mm 5.7 inches (2) 2x ( unit) 2x (3 units) DS 27PV x (3 units) DS 8 P 27DC 808 V type lack 3R, mm 2.6 inches x (2 units) DS 27DC 80 2 PV circuits DS 6 P 27PV DS 27PV 6039 S3 type lack 43D 3 () Red/Yellow 43E 3 () 200 mm 7.9 inches mm 2.6 inches mm 5.7 inches (2) 4x ( unit) 4x (2 units) () Defeatable handle. (2) Shaft guide reference is required for shaft length over 5.7 inches (400mm). Catalogue 204 6

5 ccessories External operation Use In a combiner box, located close to the solar cell strings, or located close to the inverter, we recommend to use a door interlocked external handle for its safety features. Door interlocked external operation handles include an escutcheon, are padlockable and must be utilised with an extension shaft. Example The locking function of the enclosure in the "ON" position will force the operator to safely disconnect and isolate the solar cell strings prior to any intervention. Opening the door when the switch is on "ON" position is possible by defeating the locking function using a tool (authorized persons only). The interlocking function is restored when the door is closed back. acces_50_a_2_cat S2 type handle acces_236_a_2_cat Reinforced S2 type handle Handle type Handle colour Nema degree of protection Reference lack 42F 2, 3R, Red/Yellow 42G 2 S2 4 DS lack 42D 2 Red/Yellow 42E 2 5 DS lack 43D 3 S3 6 Red/Yellow 43E 3 7 S4 lack 44D 3 Red/Yellow 44E 3 6 DS 7 DS V lack, 3R, acces_66_a_2_cat acces_52_a_2_cat access_89_a_2_cat S3 type handle S4 type handle V type handle Shaft for external handle Use Standard lengths: 7.9 in / 200 mm, 2.6 in / 320 mm, 5.7 in / 400 mm. Other lengths: please consult us. acces_44_b cat DS 5 DS 6 DS Handle type S2 S3 S4 S2 S3, S4 Dimension (inches) Dimension X (mm) Length (inches) Length (mm) Reference V DS X acces_369_a cat acces_202_a x_cat 62 Catalogue 204

6 Stype handle adapter Use For handles S2, S3 and S4. Dimensions Increases the distance between the handle grip and the door by 2 mm, for better handling. To be ordered Colour Nema degree of protection in multiples of Reference lack, 3R, acces_87_a_3_cat lternative Stype handle cover colours Use For handles S2, S3 and S4. Handle colour Other colours: please consult us. To be ordered in multiples of Handle type Reference Light grey S2, S Dark grey S2, S Light grey S Dark grey S acces_98_a_3_cat uxiliary contact Use Prebreak and signalling of positions 0 and I: to 2 NO/NC auxiliary contacts, to 2 low level NO/NC auxiliary contacts. Electrical characteristics 300. NO/NC contact Position C Type Reference 4 7 contact contacts NO/NC DS 7 DS contact Low level NO/NC auxiliary contacts Position C Type Reference contact contacts NO/NC DS 7 DS contact acces_076_a cat Terminal screen Use Top or bottom protection against direct contact with terminals or connection parts. No. of poles Position Pack Reference 4 2 P top or bottom unit P top or bottom unit P top or bottom unit P top or bottom P top or bottom unit DS 2 P top or bottom unit P top or bottom unit DS 8 P top or bottom unit DS 8 P top and bottom 2 units DS 8 P top or bottom unit acces_079_a cat Catalogue

7 ccessories (continued) ridging bars for connecting poles in series Use The bridging bars will make easy the connection of the poles in series, allowing the following configurations (). () Other connections: refer to mounting instructions. 000 VDC Rating () Quantity to be ordered Fig. Reference PV circuit DS PV circuits 4 DS DS DS DS DS PV circuits 5 DS VDC Rating () Quantity to be ordered Fig. Reference PV circuit DS DS DS PV circuits 5 DS DS Catalogue 204

8 ridging bars for connecting poles in series (continued) acces_38_a x_cat Fig. acces_382_a x_cat Fig. 2 acces_374_a x_cat Fig.4 acces_383_a x_cat Fig. 3 acces_386_a x_cat acces_378_a x_cat Fig. 5 Fig. 6 Catalogue

9 ccessories (continued) Cage terminals Use Connection of bare copper cables onto the terminals (without lugs). Optional fan out kit for ratings of 800 to 200 for connecting several cables to the switch. Rating max () Numbrer and of cables Max. number of connections per terminal Type of cable Quantity Reference 4 4 DS conductor (#6300MCM) Cu / l 2 lugs conductors (#42/0) Cu / l 2 lugs DS conductor (#2600MCM) Cu / l 2 lugs conductors (#6350MCM) Cu / l 2 lugs DS conductors (#2600MCM) Cu / l 2 lugs conductors (#2600MCM) 2 Cu / l 2 lugs conductors (#2600MCM) 3 () Cu / l 3 lugs DS conductors (#2600MCM) 2 (2) Cu / l 2 lugs conductors (#2600MCM) 3 (3) Cu / l 3 lugs () Order a fan out kit reference for connecting 3 connectors per terminal (6 in total for the switch). (2) 2 connectors per terminal with the connection kit (3) 3 connectors per terminal with the connection kits and ul_032_a Copper bar connection kits Use To allow connection between the two power terminals from a same pole for 2000 ratings. (Fig., Fig. 2 and Fig. 3) Fig. Top or bottom flat connection Quantity to Rating () Figure order per pole terminals Reference 7 DS acces_32_b x_cat Fig. 2 Fig. 3 Top or bottom edgewise connection Quantity to Rating () Figure order per pole terminals Reference 7 DS acces_33_b x_cat acces_34_b x_cat 66 Catalogue 204

10 Characteristics SIRCO PV UL98 switches have dual UL98 and IEC approval. Due to the difference in the standard test conditions, an identical product can have 2 different ratings: a "rating" as per UL98 a "rated current" as per IEC as per standard UL98 Rating () circuits Rated voltage () () circuit 000 VDC 00 2 P 2 P P 2 P 4 2 circuits 600 VDC 00 P 2 P 4 30 P 2 P 4 2 circuits 000 VDC 00 2 P 4 P 4 DS P 4 P 4 DS 4 circuits 600 VDC 00 P 4 P 4 DS 30 P 4 P 4 DS Shortcircuit capacity at 000 VDC (any circuit breaker) Prospective shortcircuit current (k rms DC) 0 () 0 () Connection terminals Min. connection wire range/ WG #6 #6 Max. connection wire range/ WG 300MCM 300MCM Mechanical characteristics Durability (number of operating cycles) Tightening torque (lbs.in/nm) 88.5/0 88.5/0 uxiliary contact Electrical characteristics as per standard IEC Rated current Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) 2 2 circuits Rated voltage Utilisation category () () circuit 000 VDC DC P 2 P P 2 P 4 circuit 500 VDC DC P 4 P 4 DS P 4 P 4 DS 2 circuits 000 VDC DC P 4 P 4 DS P 4 P 4 DS 4 circuits 600 VDC DC2 25 P 4 P 4 DS 60 P 4 P 4 DS () Without fuse during 50 ms. Catalogue

11 Characteristics (continued) as per standard UL98 Rating circuits Rated voltage () () circuit 000 VDC P 2 P P 2 P 5 2 circuits 600 VDC 30 P 2 P 4 25 P 2 P 5 2 circuits 000 VDC P 4 P 4 DS P 4 P 5 4 circuits 600 VDC 30 P 4 P 4 DS 25 P 4 P 5 4 circuits 000 VDC 25 2 P 8 P 5 DS 6 circuits 600 VDC 25 P 6 P 5 DS 8 circuits 600 VDC 25 P 8 P 5 DS Shortcircuit capacity at 000 VDC (any circuit breaker) Prospective shortcircuit current (k rms DC) 0 () 0 () Connection terminals Min. connection wire range/ WG #6 2x#6 Max. connection wire range/ WG 300MCM 600MCM Mechanical characteristics Durability (number of operating cycles) Tightening torque (lbs.in/nm) 88.5/0 28.3/4.5 uxiliary contact Electrical characteristics as per standard IEC Rated current Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) 2 2 Rated Utilisation circuits voltage category () () circuit 000 VDC DC P 2 P P 2 P 5 circuit 500 VDC DC P 4 P 4 DS P 3 P 5 2 circuits 000 VDC DC P 4 P 4 DS P 4 P 5 4 circuits 600 VDC DC2 60 P 4 P 4 DS 275 P 4 P 5 4 circuits 000 VDC DC P 8 P 5 DS 6 circuits 600 VDC DC2 275 P 6 P 5 DS 8 circuits 600 VDC DC2 275 P 8 P 5 DS () Without fuse during 50 ms. 68 Catalogue 204

12 as per standard UL98 Rating circuits Rated voltage () () circuit 000 VDC P 2 P 5 2 circuits 600 VDC 25 P 2 P 5 2 circuits 000 VDC P 4 P P 6 P 5 DS 4 circuits 600 VDC 25 P 4 P 5 4 circuits 000 VDC P 8 P 5 DS P 8 P 5 DS 6 circuits 600 VDC 25 P 6 P 5 DS 25 P 6 P 5 DS 8 circuits 600 VDC 25 P 8 P 5 DS 25 P 8 P 5 DS Shortcircuit capacity at 000 VDC (any circuit breaker) Prospective shortcircuit current (k rms DC) 0 () 0 () Connection terminals Min. connection wire range/ WG 2x#6 2x#6 Max. connection wire range/ WG 600MCM 600MCM Mechanical characteristics Durability (number of operating cycles) Tightening torque (lbs.in/nm) 28.3/ /4.5 uxiliary contact Electrical characteristics as per standard IEC Rated current Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) 2 2 Rated Utilisation circuits voltage category () () circuit 000 VDC DC P 2 P 5 2 circuits 000 VDC DC P 4 P P 6 P 5 DS 4 circuits 600 VDC DC2 275 P 4 P 5 4 circuits 000 VDC DC P 8 P 5 DS P 8 P 5 DS 6 circuits 600 VDC DC2 275 P 6 P 5 DS 275 P 6 P 5 DS 8 circuits 600 VDC DC2 275 P 8 P 5 DS 275 P 8 P 5 DS () Without fuse during 50 ms. Catalogue

13 Characteristics (continued) as per standard UL98 Rating circuits Rated voltage () () circuit 000 VDC P 2 P P 4 P 6 2 circuits 600 VDC 25 P 2 P P 6 P 6 DS 2 circuits 000 VDC P 4 P P 8 P 6 DS 4 circuits 600 VDC 25 P 4 P 5 Shortcircuit capacity at 000 VDC (any circuit breaker) Prospective shortcircuit current (k rms DC) 0 () 0 () Connection terminals Min. connection wire range/ WG 2x#6 2x #2 Max. connection wire range/ WG 600MCM 2 x 600MCM Mechanical characteristics Durability (number of operating cycles) Tightening torque (lbs.in/nm) 28.3/ /37 uxiliary contact Electrical characteristics as per standard IEC Rated current Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) 2 2 circuits Rated voltage Utilisation category () () circuit 000 VDC DC P 2 P P 4 P 6 circuit 500 VDC DC P 3 P P 8 P 6 DS 2 circuits 000 VDC DC2 275 P 4 P P 8 P 6 DS 4 circuits 600 VDC DC2 275 P 4 P 5 () Without fuse during 50 ms. 70 Catalogue 204

14 as per standard UL98 Rating circuits Rated voltage () () circuit 000 VDC P 4 P P 4 P 7 2 circuits 600 VDC P 6 P 7 DS P 6 P 7 DS 2 circuits 000 VDC P 8 P 7 DS P 8 P 7 DS Shortcircuit capacity at 000 VDC (any circuit breaker) Prospective shortcircuit current (k rms DC) 0 () 0 () Connection terminals Min. connection wire range/ WG 4x#2 4x#2 Max. connection wire range/ WG 6x 600MCM (2) 6x 600MCM (2) Mechanical characteristics Durability (number of operating cycles) Tightening torque (lbs.in/nm) 495.7/ /75 uxiliary contact Electrical characteristics as per standard IEC Rated current Thermal current at 40 C () Thermal current at 50 C () Thermal current at 60 C () Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) 2 2 circuits Rated voltage Utilisation category () () circuit 000 VDC DC P 4 P P 4 P 7 DS circuit 500 VDC DC P 8 P 7 DS P 8 P 7 DS 2 circuits 000 VDC DC P 8 P 7 DS P 8 P 7 DS () Without fuse during 50 ms. (2) Maximum 6 x 600MCM with fan out kit Catalogue 204 7

15 Characteristics (continued) as per standard UL98 Rating circuits Rated voltage () 2000 circuit 000 VDC P 8 P 7 DS Shortcircuit capacity at 000 VDC (any circuit breaker) Prospective shortcircuit current (k rms DC) 0 () Connection terminals Min. connection wire range/ WG 4x#2 Max. connection wire range/ WG 6x 600MCM (2) Mechanical characteristics Durability (number of operating cycles) Tightening torque (lbs.in/nm) 663.9/75 uxiliary contact Electrical characteristics 300 as per standard IEC Rated current 2200 Thermal current at 40 C () 2200 Thermal current at 50 C () 850 Thermal current at 60 C () 600 Rated insulation voltage U i (V) 200 Rated impulse withstand voltage U imp (kv) 2 circuits Rated voltage Utilisation category () circuit 000 VDC DC P 8 P 7 DS () Without fuse during 50 ms. (2) Maximum 6 x 600MCM with fan out kit Catalogue 204

16 Pole connections in series PV circuit 000 VDC 45 2P 67 4P Grounded Ungrounded Grounded Ungrounded Ungrounded () () sirco_084_a x_cat sirco_075_a x_cat () sirco_085_a x_cat sirco_086_a x_cat () sirco_076_a x_cat () () 7 DS 8P Grounded Ungrounded sirco_087_a x_cat sirco_088_a x_cat PV circuit 500 VDC 45 2P Grounded sirco_077_a x_cat Ungrounded () () sirco_087_a x_cat sirco_078_a x_cat 6 DS 7 DS 8P Grounded () () sirco_078_a x_cat. Front switch.. Rear switch.. Circuit. Ungrounded () (). Front switch.. Rear switch.. Circuit. Catalogue

17 Pole connections in series (continued) 2 PV circuits 000 VDC 4 DS 4P Grounded Ungrounded () () 5 4P Grounded Ungrounded 2 () () () sirco_092_a x_cat sirco_078_a x_cat sirco_089_a x_cat 2 PV circuits 500 VDC 5 DS 7 DS 8P Grounded 5 DS 6P Grounded () 2 2 () 4 PV circuits 000 VDC sirco_079_a x_cat sirco_09_a x_cat sirco_082_a x_cat () Ungrounded Ungrounded () () () () 2 2 () 2 () () () sirco_080_a x_cat sirco_08_a x_cat sirco_080_a x_cat () 2 2. Front switch.. Rear switch.. Circuit. 2. Circuit 2. () () 2 () () (). Front switch.. Rear switch.. Circuit. 2. Circuit 2. 5 DS 8P Grounded Ungrounded () () () () sirco_093_a x_cat sirco_083_a x_cat () () 2 () 3 4 (). Front switch.. Rear switch.. Circuit. 2. Circuit Circuit Circuit Catalogue 204

18 Dimensions (in / mm) 45 J J Ø 0.35 Ø 9 Ø 0.27 Ø 7 Y Ø 0.43 Ø K K H H H Ø 0.5 Ø 3 sircoul_054_a x_cat J2 J3 C No. of poles Unit C H H max. J J J2 J3 K K Y 2 P inches mm P inches mm P inches mm P inches mm DS 5 DS J J Ø 0.35 Ø 9 Ø 0.27 Ø 7 Y C Y DS Ø 0.43 Ø K H DS K H H2 Ø 0.5 Ø 3 sircoul_055_a x_cat J3 J2 H DS 5 DS 5 DS No. of poles Unit C H H H max. J J J2 J3 K K Y Y 4 P inches mm P inches mm P inches mm Catalogue

19 Dimensions (in / mm) (continued) 6 J C J Y Ø 0.4 Ø 0.5 H K2 K K H sircoul_056_a x_cat Ø 0,35 Ø H 6 No. of poles Unit C H H J J K K K2 Y 4 P inches mm DS C J J Y Y Ø 0.4 Ø 0.5 sircoul_057_a x_cat K K H H H 6 ds No. of poles Unit C H H J J K K Y Y 8 P inches mm Catalogue 204

20 Dimensions (in / mm) (continued) 7 J J Y C Ø 0.4 Ø 0.5 sircoul_058_a x_cat Taille de boîtier 7 DS C J J Y Ø 0.4 Ø 0.5 K K H H H H2 K2 K K H H 7 sircoul_06_a x_cat No. of poles Unit C H H H2 J J K K K2 Y 4 P inches mm H 7 DS No. of poles Unit C H H J J K K Y Y 8 P inches mm Catalogue

21 Dimensions for external handles (in / mm) 4 4 DS 5 Handle type S2 type Front operation Direction of operation 0 Door drilling 40 Ø Ø 7 poign_03_a gb_cat I Ø DS 6 Front operation Handle type Direction of operation Door drilling S3 type Ø Ø poign_035_a gb_cat Ø 7 78 Catalogue 204

22 7 Handle type S4 type Front operation Direction of operation Door drilling I Ø78 90 Ø 37 poign_036_a gb_cat Ø DS 7 DS Handle type V type Front operation Direction of operation I Door drilling 50 4 Ø 6,5 poign_037_a gb_cat Ø 3 50 Catalogue

23 ridging bars (in / mm) 4 4 DS ± DS Ø3 sircoul_062_a x_cat Ø ± ± sircoul_062_a x_cat DS Ø3 R 6 sircoul_047_b x_cat Ø 0.43 Ø ± ±0, sircoul_062_a x_cat sircoul_048_b x_cat Ø 0.4 Ø ± ± 0.3 Ø3 sircoul_062_a x_cat 7 7 DS Ø 0.4 Ø 0.5 sircoul_049_b x_cat Catalogue 204

24 Mounting orientation ll frames 4 DS 5 DS 6 DS 7 DS sircoul_028_a x_cat sirco_27_a x_cat sirco_27_a x_cat Terminal lugs (in / mm) 00 to to Ø Ø 0.4 Ø sirco_5_b us_cat sircoul_038_a us_cat sircoul_00_a us_cat MCM 2/0 600MCM to Ø0.2 sircoul_026_b us_cat sirco_6_b us_cat x 350MCM 2 x 600MCM Catalogue 204 8

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity

More information

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat

More information

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity

More information

What you need to know. Â Conformity to standards

What you need to know.  Conformity to standards SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

General Characteristics

General Characteristics from 63 to 31 lbs_037_a he solution for > ain switchboard > Distribution panel > Emergency switching > us tie Function he CEC ensures making and breaking on load and security breaking of any low voltage

More information

SHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98

SHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98 2014 2015 SHORT FORM CATALOGUE ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98 ATyS UL 1008 Motorized Transfer Switching Equipment from 100 to 400 A Transfer switches

More information

CATALOGUE MARINE APPLICATIONS. Energy performance solutions

CATALOGUE MARINE APPLICATIONS. Energy performance solutions CATALOGUE MARINE APPLICATIONS Energy performance solutions 2017 2018 Marine Certifications Our certified products As an independent manufacturer, we, at Socomec are committed to adapting the range and

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

Photovoltaic fuses gpv curve from 1 to 600 A, up to 1500 VDC

Photovoltaic fuses gpv curve from 1 to 600 A, up to 1500 VDC from to 600 A, up to 500 VDC Fuse protection The solution for > Photovoltaic protection fusib_03_a cat fusib_026_a cat Function fusib_030_a x_cat fusibpv_06_a cat SOCOMEC's gpv fuses protect photovoltaic

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Switching, control and protection solutions for solar applications

Switching, control and protection solutions for solar applications Switching, control and protection solutions for solar applications continuous performance www.socomec.com Summary SIRCO M PV Manually operated modulable and modular switches p. 4 SIRCO MV PV Manually

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

CATALOGUE. Solutions for Power, Control & Safety

CATALOGUE. Solutions for Power, Control & Safety CATALOGUE Solutions for Power, Control & Safety 2015 Contents An independent manufacturer... p.4 Four key applications: the benefit of a specialist... p. 5 A cutting-edge laboratory... p. 6 Socomec in

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A 2017 CTLOGUE extract SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200 Transfer switches svr_207_a.eps svr_208_a.eps The solution for > Manufacturing > Power

More information

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Protection and Connection -disconnectors OTDC and OTDCP for photovoltaic applications -disconnectors OTDC and OTDCP for photovoltaic applications DC swi-disconnectors Premium performance for DC applications

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes Protection and Connection Enclosed DC rated switchdisconnectors OTDCP from 16 to 32 Amperes Enclosed OTDC switches from 16 to 32 Amperes meet the demanding requirements of photovoltaic applications. Enclosed

More information

MANUALLY OPERATED CHANGEOVER SWITCHES

MANUALLY OPERATED CHANGEOVER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

Motorised and automatic transfer enclosed switchess

Motorised and automatic transfer enclosed switchess s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

for NH industrial and high-speed (ur) fuses from 160 to 2500 A

for NH industrial and high-speed (ur) fuses from 160 to 2500 A for NH industrial and high-speed (ur) fuses from 60 to 00 socle_066_b cat socle_046_b cat The solution for > Motor feeders > Protection of industrial cabinet Function ase Size ase IPX SOOME fuse bases

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers Supersedes October 2013 photovoltaic circuit breakers Contents Description Page Product description........................ 1 PVGard 600 Vdc........................... 2 Technical data...........................

More information

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block. PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants

More information

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Euroload Changeover Switch

Euroload Changeover Switch Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.

More information

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A Integrated products & solutions The solution for > Iron and steel industry > Cement plants > Paper mills > Sawmills > Hydraulic power packs > Automotive > Mining coff_436_a coff_434_a Strong points Function

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Distribution blocks Distribution system

Distribution blocks Distribution system nclosures & accessories new repar_043.eps The solution for > lectrical distribution Single-pole distribution blocks Multi-pole distribution bar repar_044.eps Strong points > xtensive range > asy integration

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

SWITCH DISCONNECTORS PLANET -SWITCH.

SWITCH DISCONNECTORS PLANET -SWITCH. SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

Transfer switching solutions

Transfer switching solutions CATALOGUE EXTRACT Transfer switching solutions from 40 to 6300 A 2018 Contents The SOCOMEC Group... Security and reliability for your transfer applications... Remotely operated and Automatic Transfer

More information

SIRCO PV. Disconnect switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC UL 98B & IEC

SIRCO PV. Disconnect switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC UL 98B & IEC SIRCO PV Disconnect switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC UL 98B & IEC 60947-3 You deserve safe & reliable PV installations As a PV expert, you are challenged to differentiate

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Section Contents. Disconnect Switches

Section Contents. Disconnect Switches Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Low Voltage Switches. Switches Motorized change-over switches OTM _C

Low Voltage Switches. Switches Motorized change-over switches OTM _C Low Voltage Switches Switches Motorized change-over switches OTM...12_C II I OTM 12_C Improves your permance OTM II I 0 OFF ON I 0 OFF II I ON I ssembly made easy Bridging bars quick wiring Tunnel terminals

More information

Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP

Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP Contact us ABB Oy Breakers and Switches P.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 10 22 11 Fax: +358 10 22 45708 E-Mail: firstname.surname@fi.abb.com www.abb.com The technical data and dimensions

More information

LOAD BREAK SWITCHES & SWITCH FUSES

LOAD BREAK SWITCHES & SWITCH FUSES LOD BREK SWITCHES & SWITCH FUSES Switch Fuses FSF FSF 250 FSF FSF 60 Load Break Switches FLS FLS 250 FLS FLS 60 CONTENTS General Information bout Load Break Switches & Switch Fuses Technical Characteristic

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201 Low Voltage Products SwitchLine OT change-over switches 160, 200, 0, 315, 400, 630 and 800 mps Catalogue OT7G 05_09 1SCC301012C0201 Ith / Ie /C22, 415V Ie /C23, 415V OT160E OT160E_W OT200E OT200E_W OT0E

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1 Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series B Ex9BE3C0 Ex9BHC6 www.noarkus.com NORK Ex9 Series B NORK Miniature Circuit Breakers offer these advantages: highperformance, small size, exemplary

More information

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...

More information

SIRCO MC PV. Solar Disconnect Switch up to 40 A, up to 1000 Vdc

SIRCO MC PV. Solar Disconnect Switch up to 40 A, up to 1000 Vdc SIRCO MC PV Solar Disconnect Switch up to 40 A, up to 1000 Vdc Your guarantee for safe & reliable switching of photovoltaic circuits Taking into account the specificity and technical constraints of solar

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Breakers and Switches. Switches Switch-disconnectors OT and OTM Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

PowerLine OS Switch Fuses A, 690V

PowerLine OS Switch Fuses A, 690V Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected

More information

LOAD BREAK SWITCHES AND SWITCH FUSES

LOAD BREAK SWITCHES AND SWITCH FUSES easy to install LOAD BREAK SWITCHES AND SWITCH FUSES Sixty years of innovation in developing and producing high-quality switches When Mr Kauko Hyryläinen founded KATKO in 1941, one of his key targets

More information

SIRCO PV. Load break and Isolation switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC IEC/IS

SIRCO PV. Load break and Isolation switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC IEC/IS SIRCO PV Load break and Isolation switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC IEC/IS 60947-3 You deserve safe & reliable PV installations As a PV expert, you are challenged

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information