Photovoltaic fuses gpv curve from 1 to 600 A, up to 1500 VDC

Size: px
Start display at page:

Download "Photovoltaic fuses gpv curve from 1 to 600 A, up to 1500 VDC"

Transcription

1 from to 600 A, up to 500 VDC Fuse protection The solution for > Photovoltaic protection fusib_03_a cat fusib_026_a cat Function fusib_030_a x_cat fusibpv_06_a cat SOCOMEC's gpv fuses protect photovoltaic installations against overcurrents caused by reverse currents that can occur in PV applications. fusibpv_03_a cat fusibpv_032_a cat Strong points > High breaking capacity up to 500 VDC > Product dedicated to photovoltaic installations > High reliability > Improved safety Large range Advantages High breaking capacity Up to 50 ka to 00 VDC, 30 ka to 500 VDC. Product dedicated to photovoltaic installations Operating ranges adapted to low overcurrents specific to photovoltaic systems. High reliability Absolute protection over time guaranteed by the simplicity of manufacture and function (Joule effect). No downgrading of fuse characteristics over time. Improved safety The energy released whilst eliminating the fault (fuse blowing) is contained within the cartridge (no degassing). > Associated range of switches and fuse bases, dedicated combs and connection accessories Compliance with standards > IEC > IEC > IEC What you need to know Characteristics used I SC : short circuit current of the string. I SC MAX: short circuit current of the string related to maximum sunlight density. I RM : maximum admitted reverse current. I n : fuse rating or fuse rated current (at 25 C in a RM fuse base). N c : number of strings in parallel. U e : fuse maximum operating voltage. U OC MAX: maximum open circuit voltage in the lowest temperature conditions. When to protect A PV string requires an overcurrent protection when its own maximum admissible reverse current characteristic (Irm) is less than the current generated by the rest of the installation (current generated by the other "Nc" strings). How to protect Protection against overcurrents has to be applied to both polarities, regardless of wheather the DC installation is earthed or not. 368 General Catalogue

2 from to 600 A, up to 500 VDC How to choose the right fuse protection Voltage U e > U OC MAX In the absence of complementary information use U OC MAX =.2 U OC Fuse rating determination Determination of the fuse rated current consists of choosing a protection capable of: Supporting without fusing the normal overload current during the periods of maximum sunlight density at the ambient temperature of the enclosure in which the fuse is installed, I n > I SC MAX In the absence of complementary information use ISC MAX =.4 I SC Melting and reliably clearing the fault before the PV modules are damaged by the reverse current. I n < I RM PV panels Fuse protection (x38 and RM PV) Level Combiner box Fuse protection (x38 and RM PV) Level Combiner box fusib_79_b gb_cat PV Disconnect switch Surge arrester + PV Disconnect switch Surge arrester + Fuse protection (Busbar bolted or NH and bases) Level 2 ReCombiner box Surge arrester + PV Disconnect switch Inverter General Catalogue

3 from to 600 A, up to 500 VDC References Rated voltage 00 VDC Dissipated power Rating (A) Fuse size In 0.8 In gpv cylindrical fuses Breaking capacity Reference x ka 60PV x ka 60PV x ka 60PV x ka 60PV x ka 60PV x ka 60PV 0008 x ka 60PV 00 2 x ka 60PV x ka 60PV x ka 60PV x ka 60PV x ka 60PV 0C x ka 60PV 0C32 gpv knife edge fuse 32 NH ka 60PV NH ka 60PV NH ka 60PV NH ka 60PV NH ka 60PV NH ka 60PV NH ka 60PV NH ka 60PV NH ka 60PV NH ka 60PV NH ka 60PV NH ka 60PV L ka 60PV L ka 60PV 0600 Rated voltage 500 VDC Dissipated power Rating (A) Fuse size In 0.7 In 0.8 In Breaking capacity Reference gpv cylindrical fuses 2 x PV x PV x PV x PV 0008 x PV 00 2 x PV x PV () x PV 0020 () 25 () x PV 0025 () gpv knife edge fuse 200 XL PV L PV 0400 () Rated voltage 200 VDC. Accessories Size NH Size NH2 Size NH3 Size XL Size 3L Accessories Reference Reference Reference Reference Reference Fuse blown auxiliary contact 56PV PV PV PV PV 990 Fuse base recommended 65PV 65PV 02 65PV 03 65PV General Catalogue

4 from to 600 A, up to 500 VDC Adjustment due to ambient temperature I nf = I scgen /K t Inf gpv fuse rated current. Iscgen shortcircuit current of PV generator in STC conditions. Kt derating factor. Max. ambient temperature ( C) Kt: derating factor Standard dimensions (mm) as per IEC gpv cylindrical fuses Fuse size Striker A B C x 38 Without fusib_67_a x_cat A C B 4 x 5 Without x 85 Without gpv knife edge fuse A B C D T F G Fuse size Striker max max max max fusibpv_00_a x_cat D A B C E G F NH Without NH2 Without NH3 Without XL Without L Without Time/current operation characteristics Rated voltage 00 VDC gpv cylindrical fuses x38 gpv cylindrical fuses 4x5 000 A 2A 3A 4A 6A 8A A 2A 5/6A 20A A 32A x38 gpv 4x5 gpv fusibpv_002_b gb_cat Available Current, DCTime Constant 3ms (Amps) fusibpv_003_c gb_cat Available Current, DCTime Constant 3ms (Amps) General Catalogue

5 from to 600 A, up to 500 VDC Time/current operation characteristics (continued) Rated voltage 00 VDC gpv NH knife edge fuses gpv NH2 knife edge fuses A 40A 50A 63A 80A 0A 25A 60A 200A A NH gpv NH2 gpv fusibpv_004_d gb_cat Available Current, DCTime Constant 3ms (Amps) fusibpv_033_a gb_cat Available Current, DCTime Constant 3ms (Amps) gpv NH3 knife edge fuses gpv 3L knife edge fuses A 400A A 600A XL gpv 3L gpv fusibpv_005_d gb_cat Available Current, DCTime Constant 3ms (Amps) fusibpv_006_d gb_cat Available Current, DCTime Constant 3ms (Amps) 372 General Catalogue

6 from to 600 A, up to 500 VDC Rated voltage 500 VDC gpv cylindrical fuses x85 gpv XL knife edge fuses 000 2A 4A 6A 8A A 2A 6A 20A 25A A x85 gpv XL gpv fusibpv_027_b gb_cat Available Current, DCTime Constant 3ms (Amps) fusibpv_028_b gb_cat Available Current, DCTime Constant 3ms (Amps) gpv 3L knife edge fuses A L gpv fusibpv_029_b gb_cat Available Current, DCTime Constant 3ms (Amps) General Catalogue

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM IEC High speed catalogue 10x38mm, PVM Series 600Vdc (UL), 4 to 30A A range of UL 2579 fast-acting 600Vdc midget fuse links specifically designed to protect solar power systems in extreme ambient temperature,

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

fuse-links & fuse holders PHOTOVOLTAIC

fuse-links & fuse holders PHOTOVOLTAIC fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series Description: A range of XL package fuse links specifically designed for protecting and isolating photovoltaic array combiners and disconnects. These fuse links are capable of interrupting low overcurrents

More information

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

for NH industrial and high-speed (ur) fuses from 160 to 2500 A

for NH industrial and high-speed (ur) fuses from 160 to 2500 A for NH industrial and high-speed (ur) fuses from 60 to 00 socle_066_b cat socle_046_b cat The solution for > Motor feeders > Protection of industrial cabinet Function ase Size ase IPX SOOME fuse bases

More information

CHS Controls. Photovoltaic system protection.

CHS Controls. Photovoltaic system protection. Alltid Always tillgänglig available - Alltid öppen! - Always open! - DC Interest in renewable energy such as solar power is rapidly increasing, the industry for photovoltaic modules is growing at 30-40%

More information

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

E 90 range of fuse disconnectors and fuseholders Uncompromising performance E 90 range of fuse disconnectors and fuseholders Uncompromising performance Designing simplicity ABB competence serving the most demanding customers Suitability for disconnection and switching, effective

More information

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC HelioProtection HP15NH3L SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH3L photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic

More information

INDUSTRIAL CYLINDRICAL FUSE LINKS

INDUSTRIAL CYLINDRICAL FUSE LINKS gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal

More information

Solar circuit protection application guide. Complete and reliable solar circuit protection

Solar circuit protection application guide. Complete and reliable solar circuit protection Solar circuit protection application guide Complete and reliable solar circuit protection Introduction Benefits of Eaton s circuit protection solutions Complete and reliable circuit protection for photovoltaic

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

Bussmann series photovoltaic application guide. Complete and reliable solar fusible circuit protection

Bussmann series photovoltaic application guide. Complete and reliable solar fusible circuit protection Bussmann series photovoltaic application guide Complete and reliable solar fusible circuit protection Eaton has more than 100 years of proven technical innovation to help make your operation more productive

More information

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS 1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS

More information

Bussmann series NH photovoltaic fuse links

Bussmann series NH photovoltaic fuse links Technical Data 72033 Supersedes April 204 Bussmann series NH photovoltaic fuse links BUSSMANN SERIES Product description Eaton s Bussmann series NH size photovoltaic fuse links are specifically designed

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Bussmann PV Application guide. Complete and reliable solar circuit protection

Bussmann PV Application guide. Complete and reliable solar circuit protection Bussmann PV Application guide Complete and reliable solar circuit protection Bussmann has more than 100 years of proven technical innovation to help make your operation more productive while protecting

More information

XL Photovoltaic fuse links

XL Photovoltaic fuse links Technical Data 020 Supersedes November 207 BUSSMANN SERIES Product description Eaton s Bussmann series XL fuse links are specifically designed to protect and isolate photovoltaic array combiners and disconnects.

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

Complete and reliable solar circuit protection

Complete and reliable solar circuit protection Contents Photovoltaic fuses, holders, and blocks 6 Complete and reliable solar circuit protection Description Fuses Fuse size Volts Amps PVM 13/32" x 1-1/2" 600 4-30 PVS-R RK5 600 20-400 Section page PV-_A10_

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

NH photovoltaic fuse links

NH photovoltaic fuse links Technical Data 72033 Supersedes January 207 BUSSMANN SERIES Product description Eaton s Bussmann series NH size photovoltaic fuse links are specifically designed to protect and isolate photovoltaic array

More information

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A Technical Data Effective March 0 Bussmann x38mm Photovoltaic fuses Operating class gpv and UL PV fuse links PV Fuse coordination With thin film cells and, 5 and crystalline silicon cells Description A

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

What you need to know. Â Conformity to standards

What you need to know.  Conformity to standards SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational

More information

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

Panel-mounting components

Panel-mounting components Quality Panel-mounting components For conventional cabling, Wöhner offers a comprehensive range of panel components suitable for either plate or DIN-rail mounting. Fuses and the associated connection technology

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Protistor size 120 gr 750VDC (IEC)

Protistor size 120 gr 750VDC (IEC) Protistor size 12 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS DC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination Very low I²t Extremely fast

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings Your City logo here Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems

More information

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings PV TOOLKIT DOCUMENT #3 Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems

More information

RAPIDPLUS. high speed fuse links for semiconductors

RAPIDPLUS. high speed fuse links for semiconductors high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have

More information

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality PANEL-MOUNTING COMPONENTS FUSE HOLDERS Quality For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated

More information

HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1)

HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1) HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1) THE COMMITMENT OF MERSEN IN SAFER AND MORE RELIABLE SOLAR PHOTOVOLTAIC INSTALLATIONS In the solar market Mersen is a driving force in the

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

Ultra Rapid Fuses. For Semiconductor Protection

Ultra Rapid Fuses. For Semiconductor Protection UR Ultra Rapid Fuses For Semiconductor Protection Over many decades SIBA has developed a very comprehensive product line of Ultra Rapid fuses that has achieved worldwide acceptance. SIBA's worldwide distribution

More information

RAPIDPLUS. high speed fuse links for semiconductors

RAPIDPLUS. high speed fuse links for semiconductors high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS

More information

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL GREEN PROTECT DC - distribution and protection components Cylindrical fuse-links Fuse holders for cylindrical fuse-links Accessories for cylindrical fuses NH fuse -links NH fuse bases NH fuse disconnectors

More information

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection Solar Photovoltaic Power From plan review to Final Inspection Overarching Objectives A understandable and predictable process for both the Installer and the Inspector. The installation of safe, efficient,

More information

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and adaptive technology. This technology is improving

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw REACT stores and allows you to make the most of the energy produced by your photovoltaic system. REACT is an innovative photovoltaic inverter,

More information

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC fuses 02 gg 04 am gg Cylindrical fuse links gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube

More information

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY SMT WITH MPPT TECHNOLOGY Installation and Operation Manual Model:SMT SMT Dimensions Specification Summary System Voltage 12 V/24V Rated Battery Current 12V, 5A 8A 10A 15A 20A 25A 24V, 5A 8A 10A 15A Rated

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

Switching, control and protection solutions for solar applications

Switching, control and protection solutions for solar applications Switching, control and protection solutions for solar applications continuous performance www.socomec.com Summary SIRCO M PV Manually operated modulable and modular switches p. 4 SIRCO MV PV Manually

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

DC Fuse-Links 10 x 38

DC Fuse-Links 10 x 38 DC x 38 Reliable protection of photovoltaic systems against overloads and short-circuits. System The fuse-links x 38 by EFEN are the base line of string protection in photovoltaic systems. Designed for

More information

Helio Protection. Solar solutions designed by Ferraz Shawmut. Power generation & distribution.

Helio Protection.   Solar solutions designed by Ferraz Shawmut. Power generation & distribution. 1 Helio Protection Solar solutions designed by Ferraz Shawmut www.helioprotection.com Transportation Power conversion Power generation & distribution Industrial controls Power quality 2 A free, renewable

More information

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Protection and Connection -disconnectors OTDC and OTDCP for photovoltaic applications -disconnectors OTDC and OTDCP for photovoltaic applications DC swi-disconnectors Premium performance for DC applications

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems not exceeding a total combined system ac inverter output rating of 10kW on the roof of a one- or two-family dwelling or

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000

More information

PV Fuse-Links Superior Protection of Valuable Photovoltaic Modules

PV Fuse-Links Superior Protection of Valuable Photovoltaic Modules PV Fuse-Links Superior Protection of Valuable Photovoltaic Modules Fuses have been used for electric circuit protection since late 19 th century. However, new technologies like photovoltaic (PV) power

More information

photovoltaic NEW Safe product solutions conforming to standards for Industrial Electrical Power Distribution Systems with extended product range

photovoltaic NEW Safe product solutions conforming to standards for Industrial Electrical Power Distribution Systems with extended product range Professional Photovoltaic Distributors NEW with extended product range 10 11 Safe product solutions conforming to standards for photovoltaic plants Industrial Electrical Power Distribution Systems Solar

More information

DX³ RCBO 6000A Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw SOLAR INVERTERS ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw REACT stores and allows to make the most of the energy produced by a residential photovoltaic system. 01 01 REACT-3.6/4.6-TL PV + Storage

More information

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings TOOLKIT DOCUMENT #4 Your City logo here Solar Standard Plan Simplified Microinverter and M Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for systems using utility-interactive Microinverters

More information

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus DISTRIBUTION SOLUTIONS GSec Gas-insulated switching and isolating apparatus GSec is a three-position SF6 gas-insulated switchdisconnector designed for use in medium voltage switchgear for secondary distribution

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCBO 6000 A Phase + Neutral, neutral right side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 / 10 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

DX³ RCBO 6000A Phase + Neutral, neutral on right

DX³ RCBO 6000A Phase + Neutral, neutral on right 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Solar PV Standard Plan Simplified Microinverter and ACM Systems for Oneand Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for Oneand Two-Family Dwellings County of Santa Barbara Your City logo here Solar Standard Plan Simplified Microinverter and M Systems for Oneand Two-Family Dwellings SCOPE: Use this plan ONLY for systems using utility-interactive Microinverters

More information

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI Steca Elektronik INVERTER / CHARGER WITH MPPT: 5000-48 Inverter / Charger with MPPT charge controller All-in-one: 5 kw / 5 kva pure sine wave inverter (10 kw / 10 kva up to 5 s) 80 A MPPT charge controller

More information

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST The following checklist is an outline of the general requirements found in the 2005 National Electrical Code (NEC) Article 690 for Photovoltaic

More information

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Btdin-RS RCBO 2p Phase + Neutral, neutral on right Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

Utilisation category gl/gg 500VAC with combi indicator

Utilisation category gl/gg 500VAC with combi indicator DIN-fuse-links DIN fuse-links are used for the protection of electrical installations and equipment and are common for a wide area of applications. Standardised characteristics, technical data and dimensions

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

the National PhotoVoltaic protection note 5 I rated Introduction points of interest When to Fuse, When Not to Fuse

the National PhotoVoltaic protection note 5 I rated Introduction points of interest When to Fuse, When Not to Fuse Sizing Fuses for Photovoltaic Systems per the National Electrical Code PhotoVoltaic protection note 5 By Robert Lyons, Jr. Product Manager Introduction Properly sizing fuses for photovoltaic (PV) systems

More information

CYLINDRICAL FUSES CYLINDRICAL FUSES

CYLINDRICAL FUSES CYLINDRICAL FUSES fuses 1 2 02 04 Cylindrical fuse links class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...

More information

ABB central inverters PVS to 2091 kva

ABB central inverters PVS to 2091 kva SOLAR INVERTERS ABB central inverters PVS980 1818 to 2091 kva 01 ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators

More information

MCBs and RCDs LR TM 6000

MCBs and RCDs LR TM 6000 MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A B and C curves residual current devices from 25 A to 63 A AC and A types ± ± ± ± MCBs Single pole 230/400 V± Single pole neutral 230 V± (1)

More information

ABB central inverters PVS to 2000 kva

ABB central inverters PVS to 2000 kva Solar inverters ABB central inverters 1818 to 2000 kva ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and end

More information