CATALOGUE. Solutions for Power, Control & Safety

Size: px
Start display at page:

Download "CATALOGUE. Solutions for Power, Control & Safety"

Transcription

1 CATALOGUE Solutions for Power, Control & Safety 2015

2 Contents An independent manufacturer... p.4 Four key applications: the benefit of a specialist... p. 5 A cutting-edge laboratory... p. 6 Socomec in India... p. 7 s list...p. 34 National products p. 9 Load break switches Switch disconnectors for machine control and power distribution LBS p. 10 Changeover and Bypass switches Manual and motorised changeover switches Manual COS p. 16 Fuse COS p. 22 International products CATALOGUE Solutions for Power Control & Safety of photovoltaic applications 2014 Solutions for Power Control & Safety of photovoltaic applications 2 Catalogue 2015

3 Welcome to your new SOCOMEC India product catalogue. To make it even easier, we have grouped all of our products into two major families. Our flagship products are listed below. To find out all about our comprehensive ranges, let our helping hands be your guide. Happy reading. Bypass COS p. 26 Motorised COS p. 30 CATALOGUE Changeover Switching solutions Transfer Switching Equipment from 40 to 6300 A CATALOGUE A complete range for metering, monitoring & power quality Solutions for Transfer switch equipments Complete range for metering, monitoring & power quality Catalogue

4 An independent manufacturer The benefit of a specialist 3,0 m 2 of test platforms One of the leading independent power testing labs in Europe innovative!,000 on-site interventions per year Nearly 400 experts in commissioning, technical audit, consultancy and maintenance Since its foundation more than 90 years ago, SOCOMEC continues to design and manufacture its core products in Europe. Notably solutions for its primary mission: the availability, control and safety of low voltage electrical networks. As an independent manufacturer, the Group is committed to constant innovation to improve the energy performance of electrical installations in infrastructures as well as industrial and commercial sites. 10 % of turnover invested in R&D Always at the cutting-edge of technology for innovative, high-quality products Throughout its history, SOCOMEC has constantly anticipated market changes by developing cutting-edge technologies, providing solutions that are adapted to customer requirements and fully in keeping with international standards. Optimising the performance of your system throughout its life cycle - this is the commitment carried out every day by the SOCOMEC teams around the world, wherever your business is located. SDIV 181 A MADE IN EUROPE 4 Catalogue 2015

5 Four key applications: the know-how of a specialist Critical Power Ensuring the availability of high-quality power for critical applications. Thanks to the company s wide range of continuously evolving products, solutions and services, SOCOMEC are experts in the three essential technologies that can ensure the high availability of supply to critical facilities and buildings i.e.: uninterruptible power supplies (UPS) that provide high-quality power and reduce distortion and interruptions to the mains supply due to their power storage backup, changeover of high availability sources to transfer supply to an operational backup source, continuous monitoring of installation facilities to prevent failures and reduce operating losses. Datadock Power Control & Safety Managing power and protecting individuals and property. SOCOMEC s expertise in this domain is unquestionable; the company is an undisputed leader in power switching and changeover functions, and has been a specialist manufacturer of electrical equipment since The company has long defended the benefits of fuse protection for individuals and property, and has become a major player in cutting-edge technology such as the monitoring and detection of insulation defects. SOCOMEC guarantees solutions and services which are both relevant and efficient. APPLI 575A Solar Power Guaranteeing the safety and durability of photovoltaic (PV) facilities. As experts in the solar energy equipment field, SOCOMEC has all the specialist know-how for implementing key strategic functions in on-grid and off-grid PV facilities, including: safety, through specially designed switch disconnectors to cut the DC current generated by solar panels regardless of the facility configuration and operating conditions, the reliability of DC facilities thanks to solutions preventing the degradation of insulation and electric arc failure in DC current, control of very high-efficiency energy conversion, via PV inverters, to transform all energy generated by the solar panels into power to be consumed locally or re-injected into the national grid, PV production and energy storage solutions for on-grid and off-grid applications. CORPO 413 A Energy Efficiency Improving building and facility energy efficiency. SOCOMEC solutions, ranging from sensors to the wide choice of innovative, modular software packages, are driven by experts in energy efficiency. They meet the essential requirements of managers or operators of tertiary, industrial or local authority buildings, and make it possible to: measure power consumption, identify sources of excess consumption, and raise occupant awareness, limit reactive energy and prevent associated tariff penalties, use the best tariffs, check supplier invoicing and accurately distribute energy bills amongst consumer entities. APPLI 571A Catalogue

6 A cutting-edge laboratory The backing of an expert Since 1965, the Pierre Siat test laboratory has used its expertise to guarantee the reliability and conformity of SOCOMEC products and solutions. Our customers are also welcome CORPO 342 A A decisive link Located at the Company s headquarters in Benfeld (France), the Pierre Siat test laboratory is one of SOCOMEC s main quality pillars: its contribution to the development, qualification and certification phases plays a decisive role in the process leading to the creation of a product or solution. Global scale This totally independent laboratory is recognised by the major certification bodies worldwide: a member of the ASEFA (1) and the LOVAG (2), it is accredited by COFRAC (3), UL (CTDP (4) ), CSA (shared certification) and KEMA (SMT/ WMT (5) ). It also works in partnership with numerous international certification organisations (6). The quality and safety requirements specific to each country are therefore fully taken into account. Specialist facilities With its 100 MVA (Idc 100 ka rms 1 s) short-circuit platform, three 10 ka overload platforms and numerous other test instruments in facilities covering 10 m 2, the Pierre Siat laboratory is currently the 2 nd French power laboratory. It combines expertise in electricity and mechanics, pneumatics and computing. Ongoing commitment To adapt to the increasingly demanding standards and ever more innovative and high-performance products, the Pierre Siat laboratory is permanently extending the scope of its tests, investing whenever necessary in new equipment. A vast range of tests The laboratory submits all SOCOMEC products and solutions (including those in enclosures) to numerous tests in the following fields: functional: component resistance and operating tests, dielectric: immunity to interference, dielectric insulation, overvoltage, overcurrent, mechanical: endurance and mechanical shocks, etc., environment: functional or electrical tests under extreme conditions (temperatures, salt spray, etc.), vibrations, AC / DC endurance: in operation and under controlled temperatures (arcs, LV / HV power cuts, etc.), temperature rise, electromagnetic compatibility (EMC), metrology, safety: flammability, etc. Conducted during the design and production phases, these tests guarantee the long-term reliability of the equipment sold. Customized services These test facilities and expertise are also available to our partners who require assistance with the qualification and certification of their products or equipment. We issue certificates of conformity and performance declarations upon request. For more information, visit our web site: (1) Association des Stations d Essais Françaises d Appareils électriques basse tensio (French association of low voltage electrical equipment test stations) (2) Low Voltage Agreement Group (3) Comité Français d Accréditation (French accreditation body) (4) Client test data programme (5) Supervised Manufacturer s testing / Witnessed manufacturer s testing (6) KEMA, CEBEC, UL, CSA, ASTA, Lloyd s Register of Shipping, Bureau Véritas, BBJ-SEP, EZU, GOST-R, etc. 6 Catalogue 2015

7 Socomec in India state of the art facility to meet local demands Founded in 1990, SOCOMEC India is a wholly owned subsidiary of Socomec France. An ISO certified company presence across 12 locations, having a skilled and dedicated workforce over 325 people. CORPO 425 A A flexible manufacturing structure Socomec India a state of the art manufacturing facility spread in 2100 square meter for the production of load break switches and manual changeover switches ranging from 63 A to 31 A. It also manufactures Uninterruptible Power Supply (UPS). The plant equipped with advanced manufacturing technology has embraced lean manufacturing principles by implementing a system of continuous improvements. Our objective is to provide high levels of product quality to meet our valuable customer demands at affordable cost. Solutions to meet every need Thanks to our substantial R&D resources, our product range is continuously evolving based on our contact with clients. Our solutions have been approved by the most demanding users. It caters to the application such as Critical Building, Building, Industrial, OEM, Infrastructure & Renewable energy, etc. The expert touch Certified quality products, continuous dialogue to understand customer requirements, maximum flexibility and dedication right by your side. Our experience at your service. Our specialists at your disposal Trusting us with your project means you benefit from pre- and after-sales technical support. Socomec has well qualified and trained sales, service and project management team deployed across the country. Since the team is involved in sales and after sales support, the customer requirements are well understood and suitable solutions are provided. Our qualified and dedicated maintenance engineers and technicians in India assure the peace of mind of our customers. REGAR 103 B Catalogue

8

9 National products Load break switches LBS 63 to 31 A p. 15 Changeover and bypass switches Manual changeover switches Enclosed solution All our products are as well available enclosed for direct usage in your installation. More information in the following pages. Enclosed LBS 63 to 1600 A p. 15 Manual COS Fuse COS 63 to 31 A 125 to 630 A p. 16 p. 22 Enclosed COS 63 to 31 A p. 21 Manual bypass switches Bypass COS 125 to 1600 A p. 26 Motorised changeover switches Enclosed Fuse COS 125 to 630 A p. 25 Enclosed Bypass COS 125 to 630 A p. 29 Motorised COS 125 to 1600 A p. 30 Catalogue

10 LBS Load Break Switch from 63 to 31A Load Break Switch lbs_037_a The solution for > Main switchboard > Distribution panel > Emergency switching > Bus tie Function The SOCOMEC LBS ensures making and breaking on load and security breaking of any low voltage electrical circuit. They are available in 4 poles manual operation. Operations Direct The pad lockable handle is mounted directly on the LBS and lockable in OFF position. External The pad lockable handle is to be mounted on the panel door and lockable in OFF position. The external front operation ensures that the door is interlocked in ON position. General Characteristics Very compact design Resistant to Tropical conditions and Polluted environment Quick Make & Quick Break Fully visualized breaking High thermal and Dynamic withstand capacity Available in open execution and Sheet Steel Enclosure, for top or bottom cable entry. High performance: AC23 Category Any pole suitable for Neutral Unique Safety Handle with built in door Padlock facility High Electrical and Mechanical Endurance. Strong points > Suitable for aluminium and copper connection > High reliability and performance Conformity to standards > IS/IEC Approvals and certifications > CPRI Functional diagram Terminal shrouds Extension rod Locking with key lock (RONIS) Door locking U Terminal screens 1st A.C 2nd A.C Lockable handle (3 padlocks) sirco-hpl_003_a_1_gb_cat 1st aux. contact 2nd aux. contact Direct handle operation Exterior handle operation Set of 3 aux. contacts Set of 4 aux. contacts 10 Catalogue 2015

11 LBS Load Break Switch from 63 to 31A Characteristics 63 to 630 A LBS from 63 to 630 A s GL00634POI GL01254POI GL02004POI GL024POI GL03204POI GL04004POI GL0 6304POI Thermal current I th (40 C) 63 A 125 A 200 A 2 A 320 A 400 A 630 A Max. Normal rating of fuses Insulation voltage U i (V) Dielectric strength (V) Hz 1 mn Impulse voltage (kv) Rated operational current I e (A) 415 VAC-AC 23 A VAC-AC 23 A VDC-DC 21 A VDC-DC 22 A VDC-DC 23 A VDC-DC 21 A VDC-DC 22 A VDC-DC 23 A Motor power (kw) 415V 415 VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact Motor Reactive 415 VAC (kvar) x 125 Protection Short-circuit current with fuses (ka rms) Fuse rating Peak short-circuit making capacity (ka rms) Admissible short time current 1 sec (ka rms) Making & breaking characteristics Breaking capacity (A rms) 415 VAC pf Making capacity (A rms) 415 VAC pf Endurance Mechanical No. of operations Electrical No. of operations Operating force (Nm) Connection Min. Cu cable/bus bar size (mm 2 ) x5x2 40x5x2 Min. Al cable/bus bar size (mm 2 ) x8x2 40x8x2 Accessories Handle Door Interlock assembly GI GI GI GI GI GI GI GI GI acces_288_a_1_cat acces_290_a_1_cat GI GI Catalogue

12 LBS Load Break Switch from 63 to 31A Characteristics (continued) 800 to 31 A LBS from 800 to 31 A s GL08004POI GL010004POI GL0124POI GL016004POI GL020004POI GL0204POI GL0314POI Thermal current I th (40 C) 800 A 1000 A 12 A 1600 A 2000 A 20 A 31 A Max. Normal rating of fuses x x x 12 Insulation voltage U i (V) Dielectric strength (V) Hz 1 mn Impulse voltage (kv) Rated operational currents I e (A) 415 VAC-AC 23A VAC-AC 23A VDC-DC 21A VDC-DC 22A VDC-DC 23A *12 *12 *12 * VDC-DC 21A VDC-DC 22A VDC-DC 23A Motor Power (kw) 415V 415 VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact Motor Reactive 415 VAC (kvar) 2 x 1 3 x 1 4 x x 1 6 x 1 7 x 1 9 x 1 Overload Capacity Short-circuit current with fuses (ka rms) Fuse rating x x x 12 2 x 12 Peak short-circuit making capacity (ka rms) Admissible short time current 1 sec (ka rms) Making & Breaking Characteristics Breaking Capacity (Arms) 415 VAC pf Making Capacity (Arms) 415 VAC pf Endurance Mechanical No. of Operations Electrical No. of Operations Operating Force (Nm) Connection Min. Cu Cable / Bus bar size (mm 2 ) x5x2 60x5x2 80x5x2 100x5x2 100x5x3 100x5x4 100x10x3 Min. Al Cable / Bus bar size (mm 2 ) x8x2 x10x2 63x12x2 100x8x2 100x10x3 100x10x4 Accessories (continued) Auxiliary Contact Phase barrier 1st Auxiliary Contact GI GI GI 2 nd Auxiliary Contact acces_065_a G89B765GI G89B143GI acces_036_a GI GI GI 12 Catalogue 2015

13 LBS Load Break Switch from 63 to 31A Dimensions (mm) - Load break switches - 4 Poles 63 A Direct front operation External front operation O R A J N ØX T Panel Cover Thickness 1.5mm sirco-hpl_004_a_1_gb_cat B U K S M 65 Ø L V P P P W E G C 12 D±1 D1 65x65 Ø5.5 Ø32 Door Drilling for Interlock Assy. Mounting Overall dimensions Fixing of Sw. Connection terminal Sw. Wt. A B C D D1 E G J K L M N O P R S T U V W ØX Open Ex. (kg) 4 x to 630 A Direct front operation External front operation A J O R N ØX T Panel Cover Thickness 1.5mm S L sirco-hpl_005_a_1_gb_cat B U K 65 V P P P W M F E C G 12 D± x65 Ø5.5 Ø32 Door Drilling for Interlock Assy. Mounting Overall dimensions Fixing of Sw. Connection terminal Sw. Wt. A B C D E F G J K L M N O P R S T U V W ØX Open Ex. (kg) 4 x x x x x x Catalogue

14 LBS Load Break Switch from 63 to 31A Dimensions (mm) - Load break switches - 4 Poles (continued) 800 to 1600 A Direct front operation External front operation A J O R N ØX L T 4xØ9 Ø A Panel Cover Thickness 1.5mm S 16x /12A sirco-hpl_006_a_1_gb_cat B U K 25 V P P P W Handle for 800A M F E C Handle for 1000A-1600A G A 4xØ Connection terminal 65x65 Ø5.5 D±1 81 Ø32 Door Drilling for Interlock Assy. Mounting Overall dimensions Fixing of Sw. Connection terminal Sw. Wt. A B C D E F G J K L M N O P R S T U V W ØX Open Ex. (kg) 4 x x x x to 31 A Direct front operation External front operation Panel Cover Thickness 1.5mm O A J N 11 1 T C 4xØ A 40 S sirco-hpl_007_a_1_gb_cat M B U K V P P P W F E A 4xØ Connection terminal 65x65 Ø5.5 D±1 81 Ø32 Door Drilling for Interlock Assy. Mounting Overall dimensions Fixing of Sw. Connection terminal Sw. Wt. A B C D E F J K M P S T U V W 1 Open Ex. (kg) 4 x x x Catalogue 2015

15 Enclosed LBS Load Break Switch from 63 to 1600 A Load Break Switch The solution for > OEM > Industries > Service Sector Building > Power distribution lbs_037_a Function Socomec enclosures incorporate four pole manually operated load break switches which can make and break on load and provide isolation for any low voltage electrical circuit. The enclosure provides protection against contact with live parts as well as environmental factors such as dust, water and other hazards. On load switch ON and OFF Emergency breaking Safe and local isolation of downstream loads for maintenance purpose Advantages Safety of operations Door interlocking and positive break indication provide increased safety for the operator. Inductive load breaking (AC23) This enclosure range is provided with Load Break switches which are adapted to highly inductive loads. Complete range The range offers a wide variety of variants depending on the number of poles, rating and enclosure type. General Characteristics Adapted to environments subject to chemical, dust, contamination and atmospheric corrosion risks. Black Handle pad lockable in 0/I/II position CRCA sheet (Door 1.2 mm, Body 1.6 mm) Colour shade: RAL external earthling points on each side. Wall mounted with 4 bolts Door locking system allows opening of door only in off position Incoming & outgoing easily interchangeable at site Coating of epoxy polyester powder 70 micron Removable plate top & bottom Door with solid hinges. Strong points > Suitable for aluminium and copper connection > High reliability and performance AC-23 > Complete range up to 31 A Conformity to standards > IS/IEC s & dimensions L (mm) W (mm) X (mm) (mm) H (mm) 63 GL00634POI GL01254POI GL02004POI GL024POI GL03204POI GL04004POI GL06304POI GL08004POI GL10004POI GL124POI GL16004POI coff_379_a_1_x_cat W X L H For above ratings, please consult us. Catalogue

16 COS OnLoad changeover switch from 63 to 31 A The solution for Changeover switches cos_002_a > Safe supply of medium critical loads Strong points Function The SOCOMEC COS is a manually operated 4 poles changeover switch. It provides safe changeover, source inversion or switching on load between two low voltage power circuits as well as their safety isolation. Operations Direct The pad lockable handle is mounted directly on the COS and lockable in OFF position. External The pad lockable handle is to be mounted on the panel door and lockable in OFF position. The external front operation ensures that the door is locked in ON position. Functional diagram General Characteristics 3 stable positions (I - O - II) Fully visualized breaking Bridging Bars mounted on all ratings as standard Very compact design Resistant to Tropical conditions and Polluted environment Quick Make & Quick Break High thermal and Dynamic withstand capacity Available in open execution and Sheet Steel Enclosure, for top or bottom connection AC23 Category Bounce Free contacts Any pole suitable for Neutral Unique Safety Handle with built in door Padlock facility High Electrical and Mechanical Endurance Terminal screens > Safe and easy to use > Stable positions > Large connection capabilities for direct aluminium connection Conformity to standards > IS/IEC Approvals and certifications > CPRI 1st set of aux. contacts Bridging bar 2nd set of aux. contacts Lockable handle (3 padlocks) Locking with key lock (ronis) Extension rod sirco-hpl_011_a_1_gb_cat Terminal Door cage locking U Direct handle operation Locking disc Exterior handle operation 16 Catalogue 2015

17 COS OnLoad changeover switch from 63 to 31 A Characteristics 63 to 630 A COS from 63 to 630 A s GCD00 634POI GCD0 1004POI GC0 1254POI GC0 1604POI GC0 2004POI GC0 24POI GC0 3204POI GC0 4004POI Thermal current I th (40 C) 63 A 100 A 125 A 160 A 200 A 2 A 320 A 400 A Max. Normal rating of fuses Insulation voltage U i (V) Dielectric strength (V) Hz 1 mn Impulse voltage (kv) Rated operational currents I e (A) 415 VAC-AC 23A ** VAC-AC 23A VDC-DC 21A VDC-DC 22A VDC-DC 23A VDC-DC 21A VDC-DC 22A VDC-DC 23A Motor Power (kw) 415V 415 VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact Motor Reactive 415 VAC (kvar) Protection Short-circuit current with fuses (ka rms) Fuse rating Peak short-circuit making capacity (ka rms) Admissible short time current 1 sec (ka rms) Making & Breaking Characteristics Breaking Capacity (Arms) 415 VAC pf Making Capacity (Arms) 415 VAC pf Endurance Mechanical No. of Operations Electrical No. of Operations Operating Force (Nm) Connection Min. Cu Cable / Bus bar size (mm 2 ) x5x2 Min. Al Cable / Bus bar size (mm 2 ) 25 2 x x8x2 Accessories Handle Door Interlock assembly GI GI GI GI GI GI GI acces_288_a_1_cat GI GI acces_290_a_1_cat GI GI Catalogue

18 COS OnLoad changeover switch from 63 to 31 A Characteristics (continued) 800 to 31 A COS from 800 to 31 A s GC06304POI GC08004POI GC10004POI GC124POI GC16004POI GC20004POI GC204POI GC314POI Thermal current I th (40 C) 630 A 800 A 1000 A 12 A 1600 A 2000 A 20 A 31 A Max. Normal rating of fuses x x x 12 Insulation voltage U i (V) Dielectric strength (V) Hz 1 mn Impulse voltage (kv) Rated operational currents I e (A) 415 VAC-AC 23A VAC-AC 23A VDC-DC 21A VDC-DC 22A VDC-DC 23A * 12* 12* 12* 440 VDC-DC 21A VDC-DC 22A VDC-DC 23A Motor power (kw) 415V 415 VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact Motor Reactive 415 VAC (kvar) 2 x x 1 3 x 1 4 x x 1 6 x 1 7 x 1 9 x 1 Protection Short-circuit current with fuses (ka rms) Fuse rating x x x 12 2 x 12 Peak short-circuit making capacity (ka rms) Admissible short time current 1 sec (ka rms) Making & breaking characteristics Breaking capacity (A rms) 415 VAC pf Making capacity (A rms) 415 VAC pf Endurance Mechanical No. of operations Electrical No. of operations Operating force (Nm) Connection Min. Cu cable/bus bar size (mm 2 ) 40x5x2 x5x2 60x5x2 80x5x2 100x5x2 100x5x3 100x5x4 100x10x3 Min. Al cable/bus bar size (mm 2 ) 40x8x2 x8x2 x10x2 63x12x2 100x8x2 100x10x3 100x10x4 * AC 22 A. Accessories (continued) Auxiliary contact Phase barrier 1 st Auxiliary contact Small GI GI GI 2 nd Auxiliary contact GI GI GI acces_065_a G89B136GI Big G89B143GI G89B491GI acces_036_a 18 Catalogue 2015

19 COS OnLoad changeover switch from 63 to 31 A Accessories (continued) Bridging Bars SA SA SA SA SA SA SA SA SA SA SA SA SA acces_205_a Dimensions (mm) 63 to 100 A Direct front operation External front operation R A A1 J ØX J1 L 1 S T Panel Cover Thickness 1.2mm B svr-hpl_007_a_1_x_cat K U Z V P M I W II N E G C 12 D± x65 Ø32 Ø5.5 Door Drilling for Interlock Assy. Mounting Dimensions Fixing of Sw. Connection terminal Sw. Wt. A A1 B C D E G J J1 K L M N P R S T U V W X 1 Z 4 x x Open Ex. (kg) 125 to 630 A Direct front operation External front operation R J A A1 ØX J1 L 1 T Panel Cover Thickness 1.5mm S D±1 D1 B K U II I svr-hpl_008_a_1_x_cat V P P P W N E G C 20 Ø5.5 65x65 Ø32 Door Drilling for Interlock Assy. Mounting Overall dimensions Fixing of Sw. Connection terminal Sw. Wt. Open Ex. A A1 B C D D1 E G J J1 K L N P R S T U V W X 1 (kg) 4 x x x x x x x Catalogue

20 COS OnLoad changeover switch from 63 to 31 A Dimensions (mm) 800 to 1600 A Direct front operation External front operation 4xØ9 800A Panel Cover Thickness 1.5mm R A A1 J ØX J1 L 1 T Ø x /12A B svr-hpl_009_a_1_x_cat K U V P P P W N Handle for 800A II I S Handle for 1000A-1600A G E C A 4xØ Connection terminal 65x65 Ø5.5 D±1 81 Ø32 Door Drilling for Interlock Assy. Mounting Overall dimensions Fixing of Sw. Connection terminal Sw. Wt. A A1 B C D D1 E G J J1 K L N P R S T U V W ØX 1 4 x x x x Open Ex. (kg) 2000 to 31 A Direct front operation External front operation A1 J A J C T 4xØ A 40 Panel Cover Thickness 1.5mm 9/11 10/12 B svr-hpl_010_a_1_x_cat U K 12.5 V P P P W II I S T A 4xØ Connection terminal 65x65 1/5 3/7 2/6 4/8 D±1 81 Ø5.5 Ø32 Door Drilling for Interlock Assy. Mounting Overall dimensions Fixing of Sw. Connection terminal Sw. Wt. Open Ex. A A1 B C D J J1 K P S T U V W / /5 (kg) 4 x x x Catalogue 2015

21 Enclosed COS OnLoad changeover switch from 63 to 31 A The solution for Changeover switches > Standby power coff_246_a Function Manually operated sheet steel enclosed changeover switches provide changeover, source inversion or switching under load between two low voltage power circuits, as well as their safety isolation. The enclosure provides protection against contact with live parts as well as environmental factors such as dust, water and other hazards. On load manual changeover between 2 sources Emergency breaking Selection between two loads Safe isolation of downstream loads for maintenance purpose Advantages On load operation (AC22/AC23) Manual changeover enclosures are designed for operation on load and are able to make and break mixed/inductive loads (utilisation categories AC22/AC23). Robust product Products have been designed for severe industrial conditions with chemical, pollution or atmospheric corrosion risks. s & dimensions General Characteristics Adapted to environments subject to chemical, dust, contamination and atmospheric corrosion risks. Black Handle padlockable in 0/I/II position CRCA sheet (Door 1.2 mm, Body 1.6 mm) Colour shade: RAL external earthing points on each side Wall mounted with 4 bolts Door locking system allows opening of door only in off position Incoming & outgoing easily interchangeable at site Coating of epoxy polyester powder 70 micron Removable plate top & bottom Door with solid hinges Strong points > Safe and easy to use > Stable positions > Large connection capabilities for direct aluminium cable connection Conformity to standards > IS/IEC L (mm) W (mm) X (mm) (mm) H (mm) 63 GCD00634PEI GCD01004PEI GCD01254PEI GC01604PEI GC02004PEI GC024PEI GC03204PEI GC04004PEI GC06304PEI GC08004PEI GC10004PEI GC124PEI GC16004PEI GC20004PEI GC204PEI GC314PEI coff_379_a_1_x_cat W X L H Catalogue

22 Fuse COS Fuse changeover switch from 125 to 630 A The solution for Changeover switches > Safe supply of medium critical loads, with protection sfc_001_a Strong points > Safe and easy to use > Stable positions > Large connection capabilities for direct aluminium cable connection > Overload and short-circuit current protection up to 80kA Function The SOCOMEC fuse COS is a manually operated 4 poles changeover with protective devices as HRC fuses mounted on the load side. The switch is provided with an isolating neutral and offers protection against overload and short-circuit in position I and II. General Characteristics 3 stable positions (I - O - II) Bridging Bars mounted on all ratings as standard Very compact design Resistant to Tropical conditions and Polluted environment Quick Make & Quick Break High thermal and Dynamic withstand capacity Available in open execution and Sheet Steel Enclosure for top or bottom cable connection Operations Direct The pad lockable handle is mounted directly on the Fuse COS and lockable in OFF position. External The pad lockable handle is to be mounted on the panel door and lockable in OFF position. The external front operation ensures that the door is interlocked in ON position. High performance: AC23 Category Bounce Free contacts Unique Safety Handle with built in door Padlock facility High Electrical and Mechanical Endurance BS type HRC fuses Prospective short-circuit rating with fuses up to 80kA rms Conformity to standards > IS/IEC Approvals and certifications > CPRI 22 Catalogue 2015

23 Fuse COS Fuse changeover switch from 125 to 630 A Characteristics 125 to 630 A Fuse COS from 125 to 630 A s GF01254POI (1) GF02004POI (1) GF024POI (1)(2) GF03204POI (1) GF04004POI (1)(2) GF06304POI (1)(2) Thermal current I th (40 C) 125 A 200 A 2 A 320 A 400 A 630 A Max. Normal rating of fuses Insulation voltage U i (V) Dielectric strength (V) Hz 1 mn Impulse voltage (kv) Rated operational currents I e (A) 415 VAC-AC 23A VAC-AC 23A VDC-DC 21A VDC-DC 22A VDC-DC 23A VDC-DC 21A VDC-DC 22A VDC-DC 23A Motor power (kw) 415V 415 VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC without pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact VAC with pre-break Aux. contact Motor reactive 415 VAC (kvar) x 125 Protection Short-circuit current with fuses (ka rms) Fuse rating Fuse type A4 A4 B1 B1 C1 C1 Peak short-circuit making capacity (ka rms) Admissible short time current 1 sec (ka rms) Making & breaking characteristics Breaking capacity (A rms) 415 VAC pf Making capacity (A rms) 415 VAC pf Endurance Mechanical No. of operations Electrical No. of operations Operating force (Nm) Connection Min. Cu cable/bus bar size (mm 2 ) x5x2 40x5x2 Min. Al cable/bus bar size (mm 2 ) x8x2 40x8x2 1. Includes switch + handle + door interlock. 2. A NO/NC factory fitted. Catalogue

24 Fuse COS Fuse changeover switch from 125 to 630 A Accessories Handle Door Interlock assembly GI GI GI GI GI acces_288_a_1_cat GI acces_290_a_1_cat Bridging bars Auxiliary Contact F-SA F-SA F-SA F-SA acces_205_a 1st Auxiliary Contact GI 2 nd Auxiliary Contact GI Dimensions (mm) 125 to 630 A Direct front operation External front operation PANEL COVER THICKNESS 1.5 A A1 J J1 R ØX L T 1 Incomming Supply Barriers Fuse Barrier B U K I D±1 D1 G S acces_065_a Phase barrier Fuse barrier 125 G89B 595GI G89B 596GI G89B 597GI acces_036_a 125 G GI G GI G89B 594GI O sfc_002_a_1_x_cat V P P P W N E F C 20 65X65 Ø32 (4NOS) Ø5.5 DOOR DRILLING FOR INTERLOCK ASS. MOUNTING Overall dimensions Fixing of Sw. Connection terminal Sw. Wt. Open Ex. A A1 B C D D1 E F G J J1 K L N P R S T U V W ØX 1 (kg) 4 x x x x x x Catalogue 2015

25 Enclosed fuse COS Fuse changeover switch from 125 to 630 A The solution for Changeover switches > Safe supply of medium critical loads, with protection Function sfc_001_a General Characteristics Strong points > Safe and easy to use > Stable positions > Large connection capabilities for direct aluminium cable connection > Overload and short-circuit current protection up to 80 ka Manually operated sheet steel enclosed fuse changeover switches provide changeover, source inversion or switching under load between two low voltage power circuits, their safety isolation and overload as well as shortcircuit protection. The enclosure provides protection against contact with live parts as well as environmental factors such as dust, water and other hazards. On load manual changeover between 2 sources Emergency breaking Selection between two loads Safe isolation of downstream loads for maintenance purpose Protection of the downstream load against short-circuits and overloads. Black handle padlockable in 0/I/II position CRCA sheet (Door 1.2 mm, Body 1.6 mm) Colour shade: RAL external earthing points on each side Wall mounted with 4 bolts Door locking system allows opening of door only in off position Incoming & outgoing easily interchangeable at site Coating of epoxy polyester powder 70 micron Removable plate top & bottom Door with solid hinges BS type HRC fuses Prospective short-circuit rating with fuses up to 80 ka rms Conformity to standards > IS/IEC s & dimensions L L (mm) W (mm) X (mm) (mm) H (mm) 125 GF01254PEI GF02004PEI GF024PEI GF03204PEI GF04004PEI GF06304PEI W X H sfc_009_a_1_x_cat Catalogue

26 Bypass COS Bypass changeover switch from 125 to 1600 A The solution for Changeover switches cos_005_a > Bypass of an electrical equipment. E.g. UPS... Strong points Function The SOCOMEC bypass COS is a manually operated changeover switch. It is a combination of three interlocked switches enabling the use with poles. It insulates by providing simultaneous safety isolation top and bottom and Bypassing loads of low voltage circuits mainly during maintenance operations. Operations Direct The pad lockable handle is mounted directly on the B-PASS and lockable in OFF position. External The pad lockable handle is to be mounted on the panel door and can be locked in OFF position. The external front operation ensures that the door is interlocked in ON position. General Characteristics 3 stable positions (I - O - II) Very compact design Resistant to Tropical conditions and Polluted environment Quick Make & Quick Break High thermal and Dynamic withstand capacity Available in open execution and Sheet Steel Enclosure for top or bottom cable connection High performance : AC23 category Bounce Free contacts Any pole suitable for Neutral Unique Safety Handle with built in door Padlock facility High Electrical and Mechanical Endurance > Safe and easy to use > Bypass with a single operation > Large connection capabilities for direct aluminium cable connection Conformity to standards > IS/IEC Approvals and certifications > CPRI Functional diagram atys_570_a_1_x_cat 26 Catalogue 2015

27 Bypass COS Bypass changeover switch from 125 to 1600 A Characteristics 125 to 1600 A s GBP01254POI (1) GBP02004POI (1) GBP024POI (1) (2) GBP03204POI (1) (2) GBP04004POI (1) (2) GBP06304POI (1) (2) GBP08004POI (1) (2) GBP10004POI (1) (2) GBP124POI GBP16004POI (1) (2) (1) (2) Thermal current I th (40 C) 125 A 200 A 2 A 320 A 400 A 630 A 800 A 1000 A 12 A 1600 A Max. Normal rating of fuses Insulation voltage U i (V) Dielectric strength (V) Hz 1 mn Impulse voltage (kv) Rated operational currents I e (A) 415 VAC-AC 23A VAC-AC 23A VDC-DC 21A VDC-DC 22A VDC-DC 23A * 440 VDC-DC 21A VDC-DC 22A VDC-DC 23A Motor power (kw) 415V 415 VAC without pre break Aux. contact VAC without pre break Aux. contact VAC without pre break Aux. contact VAC with pre break Aux. contact VAC with pre break Aux. contact VAC with pre break Aux. contact Motor Reactive 415 VAC (kvar) x x 1 3 x 1 4 x x 1 Protection Short-circuit current with fuses (ka rms) Fuse rating x00 Peak short-circuit making capacity (ka rms) Admissible short time current 1 sec (ka rms) Making & breaking characteristics Breaking Capacity (A rms) 415 VAC pf Making Capacity (A rms) 415 VAC pf Endurance Mechanical No. of operations Electrical No. of operations Operating force (Nm) Connection Min. Cu cablebus bar size (mm 2 ) x5x2 40x5x2 x5x2 60x5x2 80x5x2 100x5x2 Min. Al cablebus bar size (mm 2 ) x8x2 40x8x2 x8x2x x10x2 63x12x2 100x8x2 1. Includes switch + handle + door interlock. 2. A NO/NC factory fitted. Accessories Handle Bridging bars Auxiliary Contact GI GI GI GI GI GI GI Door Interlock assembly GI GI SA SA SA SA SA SA SA SA SA 1 st Auxiliary contact 2 nd Auxiliary contact GI GI GI GI GI GI Phase barrier Type Small G89B604GI Big G89B766GI Catalogue

28 Bypass COS Bypass changeover switch from 125 to 1600 A Dimensions (mm) 125 to 630 A Direct front operation External front operation PANEL COVER THICKNESS 1.5 A R J A1 ØX J1 L T E C S B U K D D1 cos_007_a_1_x_cat V P P P W N 1 2 G 15 65X65 (4NOS) Ø5.5 Ø31 DOOR DRILLING FOR INTERLOCK ASS. MOUNTING Dimensions Fixing of Sw. Connection terminal Sw. Wt. Open Ex. A A1 B C D D1 E G J J1 K L N P R S T U V W ØX 1 2 (kg) 4 x x x x x x to 1600 A Direct front operation External front operation 4Ø A Ø R A1 J A J1 L C E T U K PANEL COVER THICKNESS /12 A 16x A D D1 4XØ13 cos_008_a_1_x_cat V P P P W N 1 2 G CONNECTION TERMINAL 65X65 (4NOS) Ø5.5 Ø32 DOOR DRILLING FOR INTERLOCK ASS. MOUNTING Overall dimensions Fixing of Sw. Connection terminal Sw. Wt. Open Ex. A A1 B C D D1 E G J J1 K L N P R T U W V ØX 1 2 (kg) 4 x x x x Catalogue 2015

29 Enclosed bypass COS Bypass changeover switch from 125 to 1600 A The solution for Changeover switches > Bypass of an electrical equipment. E.g. UPS... Function Manually operated sheet steel enclosed bypass COS changeover switches provide bypass function of an electrical equipment as well as its safety isolation. The enclosure provides protection against contact with live parts as well as environmental factors such as dust, water and other hazards. On load switch ON and OFF + B-PASS mode to insulate any loads (UPS, VSD ) while maintaining the supply during maintenance. Emergency breaking Safe and local isolation of downstream + upstream for maintenance purpose General Characteristics Black Handle padlockable in 0/I/II position CRCA sheet (Door 1.2 mm, Body 1.6 mm) Colour shade: RAL external earthing points on each side Wall mounted with 4 bolts Door locking system allows opening of door only in off position Incoming & outgoing easily interchangeable at site Coating of epoxy polyester powder 70 micron Removable plate top & bottom Door with solid hinges Strong points > Safe and easy to use > Bypass with a single operation > Large connection capabilities for direct aluminium cable connection Conformity to standards > IS/IEC s & dimensions L (mm) W (mm) X (mm) (mm) H (mm) 125 GBP01254PEI GBP02004PEI GBP024PEI GBP03204PEI GBP04004PEI GBP06304PEI GBP08004PEI For above ratings, contact us W X L H cos_010_a_1_x_cat Catalogue

30 Motorised COS Motorised changeover switch from 125 to 1600 A The solution for Changeover switches cos_003_a > AMF panel Strong points Function The SOCOMEC Motorized Changeover Switch is a motor operated 4 Pole changeover switch. It provides safe changeover giving two stable position I & II and help in changeover from one supply source to another remotely. In case of control supply failure, emergency handle arrangement is provided for manual operation of switch in OFF position or selecting the supply. Operations I Circuit I close and circuit II open (transfer supply ON and generator supply OFF. II Circuit I open circuit II close ( generator supply ON and transformer supply OFF ). 0 Circuits I & II open. This position can only be achieved through manual operation and ensure a safe maintenance of the installation. General Characteristics 3 stable positions, mechanically interlocked ( I 0 II ) Optional overlapping contacts (I, I+II, II) High performance on load switching (AC-22 and AC-23) Fully apparent position through indicator Dry contact electrical position control Manual Emergency operation Locking feature available in all 3 positions Large Power control supply range: 230V +/- 15% Functional diagram 1 > Factory fitted auxiliary contacts > Stable positions > Large connection capabilities for aluminium connection Conformity to standards > IS/IEC Approvals and certifications > CPRI svrmo_006_c_1_cat Catalogue 2015

General Characteristics

General Characteristics from 63 to 31 lbs_037_a he solution for > ain switchboard > Distribution panel > Emergency switching > us tie Function he CEC ensures making and breaking on load and security breaking of any low voltage

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar

More information

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity

More information

CATALOGUE MARINE APPLICATIONS. Energy performance solutions

CATALOGUE MARINE APPLICATIONS. Energy performance solutions CATALOGUE MARINE APPLICATIONS Energy performance solutions 2017 2018 Marine Certifications Our certified products As an independent manufacturer, we, at Socomec are committed to adapting the range and

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

Euroload Changeover Switch

Euroload Changeover Switch Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They

More information

Transfer switching solutions

Transfer switching solutions CATALOGUE EXTRACT Transfer switching solutions from 40 to 6300 A 2018 Contents The SOCOMEC Group... Security and reliability for your transfer applications... Remotely operated and Automatic Transfer

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

Advanced Critical Power Solutions for UK Railway Infrastructure. reliable - tough - compact - efficient

Advanced Critical Power Solutions for UK Railway Infrastructure. reliable - tough - compact - efficient Advanced Critical Power Solutions for UK Railway Infrastructure reliable - tough - compact - efficient The world s most advanced UPS systems for the rail sector Electronic signalling, emergency lighting,

More information

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

What you need to know. Â Conformity to standards

What you need to know.  Conformity to standards SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational

More information

Motorised and automatic transfer enclosed switchess

Motorised and automatic transfer enclosed switchess s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >

More information

Load break & Transfer switching. On-load isolation and source changeover applications Low voltage switching solutions from 16 to 6300 A

Load break & Transfer switching. On-load isolation and source changeover applications Low voltage switching solutions from 16 to 6300 A Load break & Transfer switching On-load isolation and source changeover applications Low voltage switching solutions from 16 to 6300 A Power control & safety products and solutions Our mission: managing

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

General Characteristics

General Characteristics from 63 to 31 lbs_037_b he solution for > ain switchboard > Distribution panel > mergency switching > us tie unction he L ensures making and breaking on load and security breaking of any low voltage electrical

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A

Safety enclosures Normal atmospheres steel enclosure from 50 to 1600 A Integrated products & solutions The solution for > Iron and steel industry > Cement plants > Paper mills > Sawmills > Hydraulic power packs > Automotive > Mining coff_436_a coff_434_a Strong points Function

More information

Independent Testing Laboratory for High Voltage Equipment

Independent Testing Laboratory for High Voltage Equipment T E S T I N G L A B O R A T O R Y Independent Testing Laboratory for High Voltage Equipment 1 CHALLENGING ENVIRONMENT The primary concern for utilities is to ensure grid reliability, efficiency, and security.

More information

LOAD BREAK SWITCHES AND SWITCH FUSES

LOAD BREAK SWITCHES AND SWITCH FUSES easy to install LOAD BREAK SWITCHES AND SWITCH FUSES Sixty years of innovation in developing and producing high-quality switches When Mr Kauko Hyryläinen founded KATKO in 1941, one of his key targets

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

Changeover & Bypass Sw it ches

Changeover & Bypass Sw it ches Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without

More information

Integrated products & solutions

Integrated products & solutions 2017 2018 CATALOGUE EXTRACT Integrated products & solutions Enclosed switching, protection and metering systems Contents An independent manufacturer................................................. Expert

More information

Gas Insulated Switchgear

Gas Insulated Switchgear Gas Insulated Switchgear Your partner in energy solutions CG Electric Systems Hungary CG Electric Systems Hungary (previously known as Ganz Electric) has a history of over a 130 years as a high technology

More information

SHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98

SHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98 2014 2015 SHORT FORM CATALOGUE ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98 ATyS UL 1008 Motorized Transfer Switching Equipment from 100 to 400 A Transfer switches

More information

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed

sirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on

More information

SIRCO PV. Disconnect switches for photovoltaic applications From 100 to 3200 A, up to 1500 VDC UL 98B & IEC

SIRCO PV. Disconnect switches for photovoltaic applications From 100 to 3200 A, up to 1500 VDC UL 98B & IEC SIRCO PV Disconnect switches for photovoltaic applications From 100 to 3200 A, up to 1500 VDC UL 98B & IEC 60947-3 You deserve safe & reliable PV installations As a PV expert, you are challenged to differentiate

More information

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A

SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200A 2017 CTLOGUE extract SIRCOVER Manual transfer switching equipment for source changeover applications from 63 to 3200 Transfer switches svr_207_a.eps svr_208_a.eps The solution for > Manufacturing > Power

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

ATyS M Modular Transfer Switching Equipment from 40 to 160 A

ATyS M Modular Transfer Switching Equipment from 40 to 160 A ATyS M Modular Transfer Switching Equipment from 40 to 160 A ATyS M The source transfer solution that combines safety and performance Socomec transfer switching equipment helps you to secure your power

More information

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011 Low Voltage Interpact Switch-disconnectors INS/INV40 to 2500 A Catalogue 2011 Interpact INS/INV Contents Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and

More information

Power Conversion System The Best Technology for your photovoltaic and storage system

Power Conversion System The Best Technology for your photovoltaic and storage system The Best Technology for your photovoltaic and storage system The Best Technology for your photovoltaic and storage system EEI. Experience and Reliability since 1978 EEI s mission started in 1978 coming

More information

Energy Storage Solution for microgrids. from 33 kva to multiple MVA

Energy Storage Solution for microgrids. from 33 kva to multiple MVA Energy Storage Solution for microgrids from 33 kva to multiple MVA For a secure and flexible network Microgrids are groups of Distributed Energy Resources (DERS) and interconnected loads controllable as

More information

Enclosed switches. from 20 to 1600 A

Enclosed switches. from 20 to 1600 A Enclosed switches from 20 to 1600 A Why do you need an enclosed switch? Switchgear systems are an essential part of your electrical system. Present at all levels of your electrical distribution, they allow

More information

Exceeding the standards with MNS

Exceeding the standards with MNS Exceeding the standards with MNS Exceeding the standards with MNS 5 essentials of switchgear solutions Since ABB first introduced MNS the modular low voltage switchgear platform over forty years ago, MNS

More information

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems FUSERBLOC CD The universal Fuse Combination Switch FROM 20 TO 1250 A SOCOMEC GROUP SWITCHING PROTECTION & UPS Industrial Switching & Protection Systems SWITCHING FUSERBLOC CD THE UNIVERSAL FUSE COMBINATION

More information

SIRCO MC PV. Solar Disconnect Switch up to 40 A, up to 1000 Vdc

SIRCO MC PV. Solar Disconnect Switch up to 40 A, up to 1000 Vdc SIRCO MC PV Solar Disconnect Switch up to 40 A, up to 1000 Vdc Your guarantee for safe & reliable switching of photovoltaic circuits Taking into account the specificity and technical constraints of solar

More information

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel We engineer, we assure. EMC 24 SERIES METAL CLAD SWITCHGEAR Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel Saudi Cable Company REF: EMC24-EN-16-04 2 www.elimsan.com

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

MGE TM Galaxy TM 7000

MGE TM Galaxy TM 7000 MGE TM Galaxy TM 7000 Power efficiency for business continuity 160/200/250/300/400/500 kva > Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Medium to Large

More information

SIRCOVER Manual Transfer Switching Equipment from 125 to 3200 A

SIRCOVER Manual Transfer Switching Equipment from 125 to 3200 A Manual Transfer Switching Equipment from 125 to 3200 A Why do you need Transfer Switching Equipment (TSE)? Power outages can occur, even in high reliability distribution networks, leading to major incidents

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

Enclosed changeover switches Automatic operation ATSE * - Automatic equipment from 40 to 3200 A Integrated products

Enclosed changeover switches Automatic operation ATSE * - Automatic equipment from 40 to 3200 A Integrated products ATSE * - Automatic equipment from 40 to 3200 A Integrated products & solutions The solution for > High Rise Buildings. > Data centres. > Energy production. > Healthcare buildings. > Banking and Insurances.

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

CPG.0 Single busbar gas-insulated cubicles

CPG.0 Single busbar gas-insulated cubicles MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation

More information

MGE TM Galaxy TM 7000 GFC

MGE TM Galaxy TM 7000 GFC MGE TM Galaxy TM 7000 GFC Grid Frequency Converter (GFC) for Shore Connection solution 500 kva Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Shore Connection

More information

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant Schneider Electric PV Skid Optimized solar power conversion system tailored to enhance any North American PV power plant 1 PV Skid solution Integrated solution designed for optimal performance in any environment

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times. The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

The Modular System. Modular System

The Modular System. Modular System Modular System The Modular System The CUBIC modular system is based on a concept of standard modules for the construction of electrical panels. Using a relatively few standard parts it is possible to construct

More information

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A Extract of the technical catalogue - 20.10 SACE Tmax XT New low voltage molded-case circuit breakers up to 250A Circuit breakers for power distribution Main characteristics SACE Tmax XT molded-case circuit

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

ABB in primary aluminium From mine to market

ABB in primary aluminium From mine to market ABB in primary aluminium From mine to market 2 ABB IN PRIMARY ALUMINIUM FROM MINE TO MARKET Efficiency, availability, productivity and profits Price fluctuations, intense competition, and demands for improved

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

Power Electronics

Power Electronics www.nidec-industrial.com Power Electronics NIS. A Tradition in Excellence. Nidec Industrial Solutions: destined to be number one in industrial drive solutions With over 150 years of experience in the

More information

Power and Distribution Transformers

Power and Distribution Transformers Power and Distribution Transformers VRT Power Ltd. We Enable Energy VRT is a modern manufacturer for high-performance oil-immersed power transformers up to 800 MVA 500 kv. Customized design and the development

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

AC Switches: ML & MN Series DC Switches: MDC1A Series

AC Switches: ML & MN Series DC Switches: MDC1A Series AC Switches: ML & MN Series DC Switches: MDC1A Series Australian & New Zealand Distributor Leveltec Engineering Pty Ltd Gloucester P:+612 6558 9264 F:+612 6558 1002 Sydney P:+612 9299 5630 F:+612 6558

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Products and solutions for photovoltaic applications

Products and solutions for photovoltaic applications Products and solutions for photovoltaic applications Components for string and interface control panels Switch disconnectors Surge protection devices Fuse holders The range of LOVATO Electric components

More information

Powering business worldwide

Powering business worldwide Powering business worldwide Eaton delivers the power inside hundreds of products that are answering the demands of today s fast changing world. We help our customers worldwide manage the power they need

More information

Greater reliability and flexibility for large solar installations. Conext Core XC-NA series central inverters

Greater reliability and flexibility for large solar installations. Conext Core XC-NA series central inverters Greater reliability and flexibility for large solar installations Conext Core XC-NA series central inverters Conext Core XC-NA central inverters Introducing the Conext Core XC-NA outdoor-rated central

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

SIRCO PV. Disconnect switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC UL 98B & IEC

SIRCO PV. Disconnect switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC UL 98B & IEC SIRCO PV Disconnect switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC UL 98B & IEC 60947-3 You deserve safe & reliable PV installations As a PV expert, you are challenged to differentiate

More information

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1. DISTRIBUTION SOLUTIONS ZX1.5-R Gas-insulated medium voltage for railway application Safety and reliability 20% footprint saving Easy operation Complete solution ZX1.5-R Gas-insulated medium voltage for

More information

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K-11.1.2 Catalogue EN We Create Ideas With Power! e 2 ALPHA-2S double busbar switchgear is designed for use in primary and secondary electric energy

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information