Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
|
|
- Erica Hamilton
- 6 years ago
- Views:
Transcription
1 Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe (A) p. 306) - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - Recessed area for optional plate - A wide choice of associated contact blocks and enclosures versions available Pages 289 and 295 ÿ WITH CLUTCH DRIVE - Metal cuttable shafts - With or without door interlock system - Short or long metal shaft available Pages 288 and
2 Complete switch disconnectors 20 A IP 40 as standard, IP 65 on request FRONT MOUNTING PADLOCKABLE PRESENTATION Characteristics (p.306) 20 A - non-reversible terminals 3P P+NC/NO(1) P (1) Padlock with ø 6 to 8 mm A: 46 (3P/4P) 56 (3P+NC/NO) A 33 14, ,5 ACCESSORIES IP65 seal kit For front mounting with screws Terminal covers For front mounting with screws Catalogue No.in bold: normally in stock at distribution outlets 284
3 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request FRONT MOUNTING PADLOCKABLE PRESENTATION E F c D 33 C A B 17,5 (OF) Safety switch to disconnect and isolate poles. IP 20 finger safe Double break type load switching Red padlockable handle on yellow plate Actual position (ON or OFF) clearly visible Conform to standards: IEC EN Approved by UL - cul Suitable as motor disconnect A: 44 B: 75.4 C: 14.5 D: 66 E: 36 F: A 3P P+NC/NO (1) P neutral on left A 3P P neutral on left A: 53.6 B: 85 C: 17.9 D: 66 E: 50.3 F: A 3P P neutral on left A 3P P neutral on left A: 71.8 B: 93 C: 26.8 D: 86 E: 63.8 F: A 3P P neutral on left A 3P (1) Padlock: ø 6 to 8 mm 285
4 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request FRONT MOUNTING WITH PLATE, FRAME AND HANDLE E F 5 G Ø H c D C A B 17,5 (OF) Safety switch to disconnect and isolate poles. IP 20 finger safe Double break type load switching Red handle on yellow plate Actual position (ON or OFF) clearly visible Conform to standards: IEC EN Approved by UL - cul Suitable as motor disconnect A: 44 B: 75.4 C: 14.5 D: 64 E: 36 F: 50 G: 26 H: 22 ø: 28 A: 53.6 B: 85 C: 17.9 D: 72 E: 50.3 F: 60 G: 26 H: 30 ø: 28 A: 71.8 B: 93 C: 26.8 D: 96 E: 63.8 F: 70 G: 31 H: 34 ø: A 3P A 3P A 3P A 3P A 3P A 3P
5 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request FRONT MOUNTING PADLOCKABLE PRESENTATION Ø 22 SINGLE-HOLE MOUNTING ,4 Safety switch to disconnect and isolate poles. IP 20 finger safe Double break type load switching Red handle on yellow plate Actual position (ON or OFF) clearly visible Conform to standards: IEC EN Approved by UL - cul Suitable as motor disconnect 25 A 3P A 3P
6 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request REAR MOUNTING WITH CLUTCH DRIVE PADLOCKABLE PRESENTATION E X 33 c D B C A 17,5 Safety switch to disconnect and isolate poles. IP 20 finger safe With clutch drive and door interlock Double break type load switching Red handle on yellow plate Actual position (ON or OFF) clearly visible Conform to standards: IEC EN Approved by UL - cul Suitable as motor disconnect 25 A 3P (short shaft) A 3P (short shaft) and 32 A dimensions A: 44 B: 75.4 C: 14.5 D: 66 E: 31.5 X: 125 to 250 (short shaft) 250 to 400 (long shaft) 50 and 63 A dimensions A: 53.6 B: 85 C: 17.9 D: 66 E: 42.2 X: 135 to 260 (short shaft) 260 to 410 (long shaft) 50 A 3P (short shaft) A 3P (short shaft) A 3P (long shaft) A 3P (long shaft) and 100 A dimensions A: 71.8 B: 93 C: 26.8 D: 86 E: 52.6 X: 145 to 270 (short shaft) 270 to 420 (long shaft) 288
7 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request and IP 66 on enclosure version with integral handle version ENCLOSURES INTEGRAL PADLOCKABLE PRESENTATION Safety switch to disconnect and isolate poles. IP 20 finger safe With clutch drive and door interlock Double break type load switching Red handle on yellow plate Actual position (ON or OFF) clearly visible Conform to standards: IEC EN IP 66 - IK A 3P P+NC/NO (1) P A 3P P+NC/NO (1) A 3P PADLOCKABLE PRESENTATION A 220 A 33 IP 40 (2) 50 A 3P A 3P A 3P and 63 A dimensions A: and 100 A dimensions A: A 3P (1) Padlock: Ø 6 to 8 mm (2) IP 65 seal kit ref (50 to 63 A) (80 to 100 A)
8 Complete switch disconnectors 20 A IP 40 as standard, IP 65 on request Grey presentation FRONT MOUNTING PADLOCKABLE PRESENTATION 20 A - non-reversible terminals 3P , ,5 ACCESSORIES IP 65 seal kit For front mounting with screws Terminal covers For front mounting with screws
9 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request Grey presentation FRONT MOUNTING PADLOCKABLE PRESENTATION E F c D 33 C A B 17,5 (OF) Safety switch to disconnect and isolate poles. IP 20 finger safe Double break type load switching Grey padlockable handle on grey plate Actual position (ON or OFF) clearly visible Conform to standards: IEC EN Approved by UL - cul Suitable as motor disconnect 25 A 3P A: 44 B: 75.4 C: 14.5 D: 66 E: 36 F: A 3P A 3P A: 53.6 B: 85 C: 17.9 D: 66 E: 50.3 F: A 3P A 3P A: 71.8 B: 93 C: 26.8 D: 86 E: 63.8 F: A 3P (1) Padlock: ø 6 to 8 mm
10 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request Grey presentation FRONT MOUNTING WITH PLATE, FRAME AND HANDLE E F 5 G Ø H c D C A B 17,5 (OF) Safety switch to disconnect and isolate poles. IP 20 finger safe Double break type load switching Black handle on aluminium plate Actual position (ON or OFF) clearly visible Conform to standards: IEC EN UL - cul approved Suitable as motor disconnect 25 A 3P A: 44 B: 75.4 C: 14.5 D: 64 E: 36 F: 50 G: 26 H: 22 ø: 28 A: 53.6 B: 85 C: 17.9 D: 72 E: 50.3 F: 60 G: 26 H: 30 ø: 28 A: 71.8 B: 93 C: 26.8 D: 96 E: 63.8 F: 70 G: 31 H: 34 ø: A 3P A 3P A 3P A 3P A 3P
11 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request Grey presentation REAR MOUNTING PADLOCKABLE PRESENTATION E X 33 c D B C A 17,5 Safety switch to disconnect and isolate poles. IP 20 finger safe With clutch drive and door interlock Double break type load switching Grey padlockable handle on grey plate Actual position (ON or OFF) clearly visible Conform to standards: IEC EN Approved by UL - cul Suitable as motor disconnect 25 A 3P (short shaft) A 3P (short shaft) and 32 A dimensions A: 44 B: 75.4 C: 14.5 D: 66 E: 31.5 X: 125 to 250 (short shaft) 250 to 400 (long shaft) 50 and 63 A dimensions A: 53.6 B: 85 C: 17.9 D: 66 E: 42.2 X: 135 to 260 (short shaft) 260 to 410 (long shaft) 50 A 3P (short shaft) A 3P (short shaft) A 3P (long shaft) A 3P (long shaft) and 100 A dimensions A: 71.8 B: 93 C: 26.8 D: 86 E: 42.6 X: 145 to 270 (short shaft) 270 to 420 (long shaft) 293
12 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request Grey presentation REAR MOUNTING MODULAR IN-PANEL PRESENTATION B C A 45 Safety switch to disconnect and isolate poles. IP 20 finger safe Double break type load switching Black handle on grey plate Actual position (ON or OFF) clearly visible Conform to standards: IEC EN Approved by UL - cul Suitable as motor disconnect 25 A 3P A A: 44 B: 53 C: 79 3P A: 53.6 B: 63 C: A 3P A 3P A: 71.8 B: 73 C: A 3P A 3P
13 Complete switch disconnectors 25 to 100 A IP 40 as standard, IP 65 on request and IP66 on enclosure version with integral handle version Grey presentation ENCLOSURES INTEGRAL PADLOCKABLE PRESENTATION Safety switch to disconnect and isolate poles. IP 20 finger safe With clutch drive and door interlock Double break type load switching Grey padlockable handle Actual position (ON or OFF) clearly visible Conform to standards: IEC EN IP 66 - IK A 3P A 3P PADLOCKABLE PRESENTATION IP 40 (1) A 220 A A 3P A 3P and 63 A dimensions A: A 3P and 100 A dimensions A: A 3P (1) IP 65 with seal ref (50 to 63 A) (80 to 100 A)
14 Separate switch disconnectors - 25 and 32 A BLOCKS 75, pole switch body without presentation 25 A A ,5 75,4 45 Additional pole (for use in enclosure only) 25 A A Neutral pole ,5 25 A A Junction block T or N Auxiliary contact NC/NO , pole early break ,5 50,
15 Separate switch disconnectors - 25 and 32 A PRESENTATION Padlockable presentation Padlock with ø6 to 8 mm 66 - Yellow/Red Grey ø 22 single-hole-mounting - Yellow/Red C With plate, frame and handle 64 - Yellow/Red B 48 - ø 22 single-hole-mounting - Yellow/Red D A 5+1 Dim. Ref A: 64 B: 80 Dim. ref A: 48 B:
16 Separate switch disconnectors - 25 and 32 A EMPTY ENCLOSURES PADLOCKABLE PRESENTATION 150 x 100 x 96 mm Supplied with padlockable handle, weatherproof seal and relay terminal For 3 and 4-pole switches with and without NC/NO ,5 IP66-IK7 Grey base - yellow cover - red handle Grey base - grey cover - grey handle Ø Ø , WITHOUT PRESENTATION == 30 Grey - Up to 4 poles + auxiliary contact x 110 x 75 mm ,4 Ø 10 Ø 4,3 Ø 6, PADLOCKABLE OR WITHOUT PRESENTATION == Ø 10 Ø 4,3 75,4 Ø 6,5 185 Grey - Up to 6 poles + auxiliary contact x 150 x 100 mm
17 Separate switch disconnectors - 25 and 32 A ACCESSORIES Terminal covers For 3-pole body switch For additional pole, neutral pole or junction block For auxiliary contact NC/NO (pair) For early break auxiliary contact Connection terminal kit Terminal connection for ground or neutral Self-adhesive plates (for enclosures) Blank Engraved INTER PRINCIPAL Engraved MAIN SWITCH Duty labels Blank Engraved INTER PRINCIPAL Engraved MAIN SWITCH Kit for clutch drive presentation Short shaft without door interlock Long shaft without door interlock Without shaft and without door interlock Kit for door interlock IP 65 seal kit For front mounting switches and enclosures Padlockable 66 or plate and frame 64 or Padlockable 86 or plate and frame For rear mounting switches with clutch drive Padlockable 66 or plate and frame 64 or Padlockable 86 or plate and frame
18 Separate switch disconnectors - 50 and 63 A BLOCKS 85 53, pole body switch without presentation 50 A A , , Additional pole (for use in enclosure only) 50 A A Neutral pole A A Junction block T or N ,5 42 Auxiliary contact NC/NO ,5 50,5 1 pole early break
19 Separate switch disconnectors - 50 and 63 A PRESENTATION 11 Padlockable presentation Padlock: ø 6 to 8 mm Yellow/Red Grey With plate, frame and handle 72 - Yellow/Red EMPTY ENCLOSURES WITHOUT PRESENTATION = = Ø = = 85 89, Grey - Up to 4 poles + auxiliary contact x 150 x 100 mm Ø 4,3 Ø 6, Grey - Up to 6 poles + auxiliary contact x 150 x 100 mm 36 = = Ø , = = Ø 4,3 Ø 6,
20 Separate switch disconnectors - 50 and 63 A ACCESSORIES Terminal covers For 3-pole switch For additional pole, neutral pole or junction block For NC/NO auxiliary contact (pair) For early break auxiliary contact Duty labels Blank Engraved INTER PRINCIPAL Engraved MAIN SWITCH Kit for clutch drive presentation Short shaft without door interlock Long shaft without door interlock Without shaft and without door interlock kit for door interlock IP 65 seal kit For front mounting switches and enclosures Padlockable 66 or plate and frame 64 or Padlockable 86 or plate and frame For rear mounting with clutch drive Padlockable 66 or plate and frame 64 or Padlockable 86 or plate and frame
21 Separate switch disconnectors - 80 and 100 A BLOCKS 93 71, pole body switch without presentation 80 A A , Additional pole (for use in enclosure only) 80 A A ,8 Neutral pole 80 A A Junction block T or N ,5 42 Auxiliary contact NC/NO pole early break ,5 50,
22 Separate switch disconnectors - 80 and 100 A PRESENTATION Padlockable presentation Padlock: ø 6 to 8 mm 86 - Yellow/Red Grey With plate, frame and handle 96 - Yellow/Red EMPTY ENCLOSURES WITHOUT PRESENTATION = = Ø 10 Grey - Up to 3 poles + auxiliary contact x 150 x 100 mm 106, = = Ø 4,3 Ø 6, Grey - Up to 6 poles + auxiliary contact x 200 x 100 mm Ø 10 = = 36 == Ø 4,3 Ø 6,
23 Separate switch disconnectors - 80 and 100 A ACCESSORIES Terminal covers For 3-pole body switch For additional pole, neutral pole or junction block For NC/NO auxiliary contact (pair) For early break auxiliary contact Duty labels Blank Engraved INTER PRINCIPAL Engraved MAIN SWITCH Kit for clutch drive presentation Short shaft without door interlock Long shaft without door interlock Without shaft and without door interlock kit for door interlock IP 65 seal kit For front mounting switches and enclosures Padlockable 66 or plate and frame 64 or Padlockable 86 or plate and frame For rear mounting with clutch drive Padlockable 66 or plate and frame 64 or Padlockable 86 or plate and frame
24 Technical characteristics GENERAL Characteristics 20 A 25 A 32 A 50 A 63 A 80 A 100 A Rated insulation voltage Ui (V) Conventional free air thermal current Ith Uninterrupted rated current Iu (A) Conventional enclosed thermal current Ithe (A) Rated impulse withstand voltage (overvoltage category III - pollution degree 3 Uimp (kv) Rated operating current Ie (A) AC - 21 A/22 A Conform to IEC Rated operating power (kw) AC 23 A 3 x 230 V x 400 V x 500 V x 690 V AC 3 3 x 230 V x 400 V x 500 V x 690 V Make - break characteristics (Aeff/400 V) Rated make capacity Rated break capacity Short circuit characteristics Rated short term withstand current Icw (Aeff/400 V/1 s) Rated short circuit make capacity Icm (ka peak/400 V) Short circuit current (ka eff/400 V) with fuse gl/gg (A) Mechanical life AC 20 (million) Connections Stranded wire + (min/max) cap (mm 2 ) 0.75/ /6 0.75/6 1.5/16 1.5/16 2.5/35 2.5/35 Solid wire (mm 2 ) Storage temperature -30 C to +70 C Operating temperature - 30 C to +70 C Protection rating rear of panel: IPxxB front of panel IP 40 in standard version (IP 65 on request) Conformity to standards IEC EN , UL508, CSA22.2 Approvals UL - cul (USA - Canada) suitable as motor disconnect. CB certification Climatic resistance Tropical atmosphere according to IEC Cyclic damp heat 306
25 Technical characteristics AUXILIARY CONTACTS Characteristics 20 A 25 A 32 A 50 A 63 A 80 A 100 A Rated insulation voltage Ui (V) Conventional free air thermal current Ith Continuous rated current Iu (A) Rated operating current Ie (A) AC V V Protection against short circuit by fuse gg (A) Max. connection stranded wire (mm2) 2 x x x x x x x 2.5 ENCLOSURES Characteristics 150x100x96 220x150x x150x x150x x150x x200x100 Rating 20, 25 and 32 A 25 and 32 A 50 and 63 A 50 and 63 A 80 and 100 A 80 et 100 A 3P to 4P 6P and 6P 3P to 4P 6P and 6P 3P and 3P 4P to 6P +NC/NO +NC/NO +NC/NO +NC/NO +NC/NO +NC/NO 20 A - 6P Cable inputs 2 x 2 Pg 16 2 x 2 Pg 21 2 x 2 Pg 21 2 x 2 Pg 29 2 x 2 Pg 29 2 x 2 Pg 21 or 2 x 2 M25 and 2 x 2 Pg 29 Ø knockouts (mm) Pg 16: and 28.5 ISO M25: 25 No. of knockouts (top and bottom) Panel mount by 2 screws by 4 screws Base/cover assembly by 1 screws by 4 screws by 6 screws self-tapping self-tapping self-tapping stainless steel stainless steel stainless steel Switch/base assembly on 35 mm DIN rail (this rail is notched for positionning the switch) Handles mounting screwing on shaft pre-pierced cover Insulation Class II installed (provided that the correct insulation plugs are used with the enclosure) Impact withstand IK07 Flameproof 650 C Protection rating IP 66 IP 40 (IP 65 upon request) Contact operating diagram 0 1/L1 3/L2 5/L3 2/T1 4/T2 6/T3 Switch disconnector Auxiliary contacts 1/L1-2/T1 3/L2-4/T2 5/L3-6/T3 Switch padlocking In general: up to 3 padlocks ø 4 to 8 mm Switch with 1 auxiliary contact NC/NO: up to 3 padlocks ø 6 to 8 mm Modular presentation: 1 padlock ø 6 to 8 mm
26 Enclosure selection guide 25 AND 32 A Enclosure 150 x 100 x 96 mm Enclosure 220 x 150 x 100 mm or Example: switch disconnector 32 A Enclosed 4 poles, padlockable presentation or 6P and 6P + NC/NO 3P to 4P + NC/NO 50 AND 63 A Enclosure 220 x 150 x 100mm Enclosure 220 x 150 x 100 mm 6P and 6P + NC/NO Example: switch disconnector 50 A Enclosed 6 poles, Plate, frame and handle presentation 3P to 4P + NC/NO 308
27 Enclosure selection guide 80 AND 100 A Enclosure 220 x 150 x 100 mm Enclosure 300 x 220 x 100 mm Example: switch disconnector 100 A Enclosed 4 poles, padlockable presentation 3P and 3P + NC/NO 4P and 6P + NC/NO LEGEND basic 3-pole block additional pole additional neutral pole junction block Auxiliary contact NC/NO early break auxiliary contact 309
28 Possible configurations Early break auxiliary contact 3-pole body switch Junction block or Auxiliary contact Auxiliary contact 3-pole body switch Junction block Auxiliary contact Junction block or Junction block Additional neutral pole Additional neutral pole 3-pole body switch Early break auxiliary contact or auxiliary contact Additional neutral pole 3-pole body switch junction block Auxiliary contact junction block or junction block auxiliary contact Additional neutral pole Additional neutral pole 3-pole body switch auxiliary contact or junction block auxiliary contact Additional phase pole Additional phase pole 3-pole body switch Additional phase pole Additional phase pole Additional phase pole Additional phase pole (1) (1) (1) version with enclosure only Complete switch disconnector p. 284 to 295 Permitted auxiliaries 310
Switch Disconnectors
Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationKATKO Safety Switches:
KATKO Safety Switches: Reliability, Economy, Safety KATKO/2007.01/AL 1 KUM 16-25A Dimensions: Overall: 130,4 x 96,4 x 42,0 Mounting holes: 118,0 x 84,0 -Polycarbonate or ABS IP65 enclosure -Excellent UV
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationApprovals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking
MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationK30H001YP cam star-delta switch - 3-pole A - screw mounting
Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationApprovals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking
MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional
More informationSAFETY SWITCHES / ISOLATORS A TECHNICAL DATA
ENCLOSED SWITCHES SAFETY SWITCHES / ISOLATORS 16-800A TECHNICAL DATA Safety switches / isolators 10A 16A 25A 40A 63A 80A 125A 160A 200A 250A 315A 400A 630A 800A Rated Insulation voltage Ui (V) 690 690
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More information70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX
70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency
More informationDCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC
More informationCylindrical fuse-link
Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH
More informationMSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3
Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationSafety rope switches with reset for emergency stop
Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions
More informationAn innovative technology
The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationDISCONNECT SWITCHES (16 TO 630 amp)
I DISCONNECT SWITCHES (16 TO 630 amp) Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We carry a complete line of UL approved, CSA listed, Disconnect
More informationLOAD BREAK SWITCHES AND SWITCH FUSES
easy to install LOAD BREAK SWITCHES AND SWITCH FUSES Sixty years of innovation in developing and producing high-quality switches When Mr Kauko Hyryläinen founded KATKO in 1941, one of his key targets
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationSolar Installer Range. Bright solutions
Solar Installer Range Bright solutions IMO is at the forefront of control component technology specifically developed for the renewable energy market and in particular solar energy. Whether meeting the
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationPendant control stations 6
Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment
More informationChangeover & Bypass Sw it ches
Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without
More informationLOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA
LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationFOOT SWITCHES
- 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationIEC Load Switches Bulletin 194E 25 Amps to 100 Amps
Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationSafety rope switch with reset for emergency stop
Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More informationEuroload Changeover Switch
Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.
More informationSWITCH DISCONNECTORS PLANET -SWITCH.
SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
haracteristics pendant control station XA-A - 8 pushbuttons Main Range of product Product or component type Device short name omplementary ontrol station type Enclosure material Electrical circuit type
More informationHS1E Series Full Size Interlock Switch with Locking Solenoid
HS1E Series HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Key features include: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationLV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity
LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact
More information25A 25A 32A 40A 40A 63A 63A 80A
ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A
More informationJCAM SWITCHES. Model Ratings / Product Numbering System...J2 Technical Data...J3
Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We offer complete line of Cam Switches with as many as 24 switch contacts. Each contact has two fixed
More informationPendant stations for small hoist application, in single / double row or direct power circuits switchings and tail lift controls.
Lifting equipment Contents Pendant stations for small hoist application, in single / double row or direct power circuits switchings and tail lift controls. page 12 to 25 Giovenzana International Company,
More informationDPX 160 Thermal magnetic and trip-free switches DPX-I 160
87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationAC Switches: ML & MN Series DC Switches: MDC1A Series
AC Switches: ML & MN Series DC Switches: MDC1A Series Australian & New Zealand Distributor Leveltec Engineering Pty Ltd Gloucester P:+612 6558 9264 F:+612 6558 1002 Sydney P:+612 9299 5630 F:+612 6558
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More informationSafety switches with solenoid and separate actuator
Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationApprobationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking
Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description
More informationApprovals (p. 906) 0 371 61 0 371 63 0 371 64 0 371 66 0 371 69 0 371 68 0 371 00 0 371 08 0 371 20 Connecting (p. 300) 1 connection - 1 entry/1 outlet ELECTRICAL FUNCTION TERMINAL BLOCKS INSULATION EQUIPOTENTIAL
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationFL series position switches
FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable
More informationSafety switches with solenoid and separate actuator
Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because
More informationK63F003UP cam changeover switch - 3-pole A - screw mounting
Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product
More informationK50F003UP cam changeover switch - 3-pole A - screw mounting
Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product
More informationReferences 4 Fuse carriers
References components 000_ -pole basic blocks Rating Cartridge fuse size umber of early break contacts () Single-phase protection device () Reference () Connection by spring terminals A 0 x 8 () Without
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationØ64 LOAD BREAK SWITCHES Ø4.5 Ø12 Ø48. Panel Door
Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 O I II Ø4 Panel Door on to the best GEERAL Contents General IDEX Page o. Technical Data 1 ing Programmes 2 Front 3 Rear 5 Plastic Enclosure Metal Enclosure Accessories
More informationMS25, MST25, MS20, MST20
Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers
More informationTeSys GS & DF Fuse protection
TeSys GS & DF Fuse protection Simple and effective protection TeSys GS Fuse disconnect switches Total isolation between poles Safe replacement of the fuses (double breaking system) Frontal and right side
More informationControl and Load Switch Specifications Bulletin Number 194E, 194L
Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13
More informationStandard Interlock Safety Switches
Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with
More informationMANUALLY OPERATED CHANGEOVER SWITCHES
are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,
More informationApplication Mini Contactors for Motors and Resistive Loads
Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads
More information68 Q-DIN Range. Trade Catalogue Energy 2013 > Energy > Combined units to IEC 309 > 68 Q-DIN Range. Distribution boards UNWIRED VERSIONS
Kombi cent r al er 0 8 5 9 41 1 83 0 www. mwa. s ei nf o@mwa. s e UNWIRED VERSIONS Type No. EN 50022 modules 1 IEC 309 socket-outlet 16A IP44/67 or GW 27 401 or GW 27 403 watertight cap GW 68 018 N 2 IEC
More informationLimit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.
Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with
More informationXCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx
Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ
More informationSwitches disconnectors with fuse-holders. XNF series TF series
Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationDPX 1600 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationDPX 630 Electronic release
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationXB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS
Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device
More informationSwitches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference
Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories
More informationLow Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011
Low Voltage Interpact Switch-disconnectors INS/INV40 to 2500 A Catalogue 2011 Interpact INS/INV Contents Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and
More informationLimit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66
Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationSIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.
Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity
More informationLimit Switches - Limit Type (PS21L) Metal Body IP66
Limit Switches - Limit Type (PS21L) Metal Body IP66 High mechanical resistance Degree of protection IP66 Zinc alloy (Zamack) or aluminium body Positive Opening Operation Minimum Actuation Force/Torque
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More information