C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

Size: px
Start display at page:

Download "C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V"

Transcription

1 DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB DB DB IEC PB eps PB eps The C60H-DC supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewable energy...). They combine the following functions of circuit protection against short-circuit and overload currents, control and isolation. e Direct current (DC) Breaking capacity (Icu) according to IEC Type Rated service breaking capacity (Ics) 1P 110 V 220 V 250 V 440 V 500 V Rating 0.5 to 63 A 20 ka 10 ka 6 ka % Icu (In) 2P (in series) 110 V 220 V 250 V 440 V 500 V 0.5 to 63 A - 20 ka 20 ka 10 ka 6 ka 75 % Icu Catalogue numbers C60H-DC Type 1P 2P DB DB DB Auxiliaries Supply from above or below, observing the polarity Supply from above Remote signalisation and tripping, module CA Supply from below Rating (In) Curve C Curve C 0.5 A A9N61500 A9N A A9N61501 A9N A A9N61502 A9N A A9N61503 A9N A A9N61504 A9N A A9N61505 A9N A A9N61506 A9N A A9N61508 A9N A A9N61509 A9N A A9N61510 A9N A A9N61511 A9N A A9N61512 A9N A A9N61513 A9N A A9N61514 A9N A A9N61515 A9N A A9N61517 A9N A A9N61518 A9N A A9N61519 A9N61539 Number of modules of 9 mm 2 4 Accessories Modules CA and CA CA901024E Version : /05/

2 DC circuit supplementary protectors for feeders / distribution systems C60H-DC (cont.) C curve Connection Without accessory With accessories DB mm 6.5 mm Rating Tightening torque Copper cables Rigid / Stranded Flexible or with ferrule 50 mm² Al Screw-on connection for terminal terminal ring terminal Multi-cables Rigid cables Flexible cables O-OFF O-OFF PZ2 y 25 A 2.5 N.m 1 to 25 mm 2 1 to 16 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 > 25 A 3.5 N.m 1 to 35 mm 2 1 to 25 mm 2 - DB Multi-cables connection 14 mm 6.5 mm Rating Tightening torque Without accessory 2 Copper cables 3 Multi-cables / Different wires Rigid / Stranded Flexible or with ferrule Flexible / Stranded Flexible / Stranded / Rigid DB DB DB DB DB DB DB DB O-OFF O-OFF PZ2 y 25 A 2.5 N.m 2 x 1 mm 2 to 2 x 10 mm 2 3 x 1 mm 2 2 x 2.5 mm x 1.5 mm 2 > 25 A 3.5 N.m 2 x 1 mm 2 to 2 x 16 mm 2 3 x 4 mm 2 2 x 10 mm x 6 mm 2 DB Technical data b Tripping curves: C curve - Overcurrent protection for any type of application. b Positive break indication - the green strip indicates that all the poles are open and allows work to be carried out on the downstream circuit in complete safety. b b Increase in the service life of the product: thanks to fast closure independent of the speed of action on the handle. b Current limitation in the event of a fault: fast opening of the contacts prevents the loads from being destroyed in the event of a short-circuit. PB eps DB DB IP40 Main characteristics According to IEC Insulation voltage (Ui) 500 V DC Rated voltage (Un) 1P 250 V DC 2P 500 V DC Operating voltage (Ue) 1P V DC 2P Pollution degree 3 Rated impulse withstand voltage (Uimp) under frame V DC Magnetic tripping (Ii) 8.5 In (± 20 %) (compatible with curve C) Additional characteristics Degree of protection Device in modular IP40 (IEC 60529) enclosure Utilization category A (no delay in accordance with IEC standards) 6 kv Endurance (O-C) Electrical 3,000 cycles (where L/R=2 ms) Mechanical 6,000 cycles where the circuit is resistive 20,000 cycles Tropicalization (IEC ) Treatment 2 (relative humidity 95 % at 55 C Operating temperature -25 C to 70 C Storage temperature -40 C to 85 C d Failure to match polarity during connection may lead to a fire hazard and/or serious injury. b The connection polarity must be observed (marked on the front panel). b Use only with direct current. 112 Version : /05/2015 CA901024E

3 DC circuit supplementary protectors for feeders / distribution systems C60H-DC (cont.) C curve Weight (g) Circuit-breaker Type 1P 2P C60H-DC 128 g 256 g Dimensions (mm) DB DB t t t 35 Details of minimum distance between circuit-breaker and earthed metal parts for circuit-breaker intended for use without enclosure. CA901024E Version : /05/

4 DC circuit supplementary protectors for photovoltaic installations PB The is a DC circuit breaker dedicated to multi string photovoltaic installations. This circuit breaker is designed to protect the cables located between each string of photovoltaic modules and the photovoltaic inverter against overloads and short circuits (see application diagram). Combined with a switch (of the C60NA-DC type, for example), the will be installed in a string PV protection enclosure at the end of each string of photovoltaic modules. It can be locked (by a padlocking device) in OFF position as a safety measure for removal of the PV inverter. can detect and protect against any bidirectional current. To ensure the safety of the installation, it is necessary, depending on the various types of application, to combine the with: b a residual current device at the AC end, b a fault passage detector (insulation monitoring device) at the DC end b an earth protection circuit breaker at the DC end (see Practical Advice CA908035). In all cases, fast action on site will be required to clear the fault (protection not ensured in the event of a double fault). is not polarity sensitive: (+) and (-) wires can inversed without any risk. The is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. IEC / EN e DB Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) 1.5 ka Impulse voltage (Uimp) 6 kv Electrical connection By the bottom for In and Out Number of poles 2P Number of modules of 9 mm 8 Diagrams DB DB IN IN OUT OUT IN OUT Standards IEC EN Rating (A) Catalogue numbers 1 A9N A9N A9N A9N A9N A9N A9N A9N A9N A9N A9N61660 Auxiliaries See modules CA and CA Version : /05/2015 CA901031E

5 DC circuit supplementary protectors for photovoltaic installations (cont.) Application diagram DB String PV protection enclosure Photovoltaic string modules PV Inverter protection enclosure PV Inverter C60NA-DC* iprd 40r PV C60NA-DC* iprd 40r PV PV Inverter protection enclosure PV Inverter iprd 40r PV C60NA-DC* iprd 40r PV MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF *C60NA-DC: 20 A/1000 V DC or 32 A/800 V DC or 50 A/700 V DC CA901031E Version : /05/

6 DC circuit supplementary protectors for photovoltaic installations (cont.) Technical data b Position contact indication - suitability for isolation according to IEC/EN standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Pre-wired product: Input / Output on the same side. Main characteristics Rated service breaking capacity (Ics) 100 % of the Icu Endurance (O-C) Electrical 1,500 cycles (where L/R=2 ms) Mechanical 20,000 cycles Mechanical Degree of pollution 2 Category Degree of protection (IEC 60529) Tropicalisation Device in modular enclosure 20,000 cycles A (no delay in accordance with IEC / EN standards) IP40 Temperature Operating -25 C to 70 C Storage -40 C to 85 C Relative humidity: 95 % at 55 C in accordance with IEC and GB standards Additional characteristics Rating (A) Voltage drop (mv) Power loss (W) Derating table (A) Ambient temperature ( C) Rating A A A A A A A A A A A Version : /05/2015 CA901031E

7 DC circuit supplementary protectors for photovoltaic installations (cont.) Technical data (cont.) Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the protective devices to provide greater insulation of the terminal screws b a spacer clips 9 mm in each side to provide isolation. DB DB DB d Required to have a 9 mm space isolation in each side" 9 mm mini 9 mm mini Weight (g) Circuit breaker Type 545 DB Dimensions (mm) Connection Without accessory With accessories DB Rating Tightening torque Copper cables UL 486A 50 mm 2 Cu/Al Terminal Ring tongue terminal screw connection Rigids Flexibles with ferrule PZ2 14 mm 6.5 mm DB DB DB DB y 25 A 2.5 N.m 1 to 25 mm 2 1 to 16 mm 2 50 mm 2 Ø 5 mm CA901031E Version : /05/

8 DC main switch for photovoltaic installations C60NA-DC PB The C60NA-DC is a direct current switch-disconnector dedicated to disconnection of the string of photovoltaic modules and the PV inverter. It is designed to isolate the string of photovoltaic modules and the inverter from the rest of the photovoltaic installation for maintenance operations in complete safety. Combined with a circuit breaker (of the type, for example), the C60NA-DC will be installed in a string PV protection enclosure close to the strings of photovoltaic modules. It can also be installed near the PV inverter. It can be locked (by a padlocking device) in OFF position to ensure safety during maintenance operations. the C60NA-DC can switch a multi-directional current. C60NA-DC is not polarity sensitive: (+) and (-) wires can inversed without any risk. The C60NA-DC is delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. IEC / EN e DB Main characteristics Operating voltage (Ue) Rated insulation voltage (Ui) Rated operational current (Ie) Impulse voltage (Uimp) Permissible rated short-time withstand current (Icw) Rated short-circuit closing current (Icm) Electrical connection Number of poles Number of modules of 9 mm 8 Diagrams DB A: 1000 V CC 32 A: 800 V CC 50 A: 700 V CC 1,000 V DC 50 A 6 kv 600 A 1 ka By the top for In and Out 2P DB IN OUT IN IN OUT OUT Standards IEC EN Catalogue number Auxiliaries A9N61690 See modules CA and CA Version : /05/2015 CA901032E

9 DC main switch for photovoltaic installations C60NA-DC (cont.) Application diagram DB String PV protection enclosure Photovoltaic string modules Diagram with C60NA-DC for current y 20 A PV Inverter protection enclosure PV Inverter C60NA-DC* iprd 40r PV C60NA-DC* iprd 40r PV Diagram with SW60-DC for current between 20 and 50 A PV Inverter protection enclosure PV Inverter iprd 40r PV C60NA-DC* iprd 40r PV *C60NA-DC: 20 A/1000 V DC or 32 A/800 V DC or 50 A/700 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD24 CA901032E Version : /05/

10 DC main switch for photovoltaic installations C60NA-DC (cont.) Technical data b Position contact indication - suitability for isolation according to IEC/EN standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Pre-wired product: Input / Output on the same side. Endurance (O-C) Electrical 300 cycles Mechanical Degree of pollution 2 Category Degree of protection (IEC 60529) Tropicalisation Device in modular enclosure 20,000 cycles DC21B IP40 Temperature Operating -25 C to 70 C Storage -40 C to 85 C Relative humidity: 95 % at 55 C in accordance with IEC and GB standards Derating table (A) C60NA-DC Ambient temperature ( C) Rating A Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the C60NA-DC protective devices to provide greater insulation of the terminal screws b a Spacer clips 9 mm in each side to provide isolation. DB DB DB mm mini 9 mm mini d Required to have a 9 mm space isolation in each side" 120 Version : /05/2015 CA901032E

11 DC main switch for photovoltaic installations C60NA-DC (cont.) Technical data (cont.) Weight (g) Switch disconnector Type C60NA-DC 530 DB Dimensions (mm) DB Connection Without accessory With accessories 14 mm PZ2 6.5 mm Rating Tightening torque Copper cables UL 486A Rigids Flexibles with ferrule 50 mm 2 Cu/Al Terminal Screw on connection for ring terminal Multi-cables terminal Rigid cables Flexible cables DB DB DB DB DB A 3.5 N.m 1 to 35 mm 2 1 to 25 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 CA901032E Version : /05/

12 DC main switch for photovoltaic installations Switch SW60-DC PB The SW60-DC is a direct current switch-disconnector dedicated to disconnection of the string of photovoltaic modules and the PV inverter. It is designed to isolate the inverter from the rest of the photovoltaic installation for maintenance operations in complete safety. Combined with a circuit breaker (of the type, for example) and a switch (of the C60NA-DC type, for example), the SW60-DC will be installed in the string PV protection enclosure close to the PV inverter (see application diagram). It can be locked (by a padlocking device) in OFF position to ensure safety when removing the PV inverter. SW60-DC is polarity sensitive: (+) and (-) has to be respected for connection. The SW60-DC is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors. IEC / EN e DB General technical data Operating voltage (Ue) Rated insulation voltage (Ui) Rated operational current (Ie) Impulse voltage (Uimp) Permissible rated short-time withstand current (Icw) Rated short-circuit closing current (Icm) Electrical connection Number of poles Number of modules of 9 mm 8 Diagrams DB V DC 1000 V DC 50 A 6 kv 600 A 1 ka By the top for In and Out 2P DB IN OUT OUT IN IN OUT OUT IN Standards IEC EN Catalogue number A9N Version : /05/2015 CA901030E

13 DC main switch for photovoltaic installations Switch SW60-DC (cont.) Applications DB String PV protection enclosure Photovoltaic string modules Diagram with SW60-DC for current between 20 and 50 A C60NA-DC* iprd 40r PV PV Inverter protection enclosure PV Inverter iprd 40r PV C60NA-DC* iprd 40r PV *C60NA-DC: 20 A/1000 V DC or 32 A/800 V DC or 50 A/700 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD24 CA901030E Version : /05/

14 DC main switch for photovoltaic installations Switch SW60-DC (cont.) Technical data Main characteristics b Position contact indication - suitability for isolation according to IEC/EN standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Pre-wired product: Input / Output on the same side. Endurance (O-C) Electrical 1,500 cycles Mechanical Degree of pollution 2 Category Degree of protection (IEC 60529) Tropicalisation Device in modular enclosure 20,000 cycles DC21A IP40 Temperature Operating -25 C to 70 C Storage -40 C to 85 C Rating adjustment 40 C Relative humidity: 95 % at 55 C in accordance with IEC and GB standards Additional characteristics Rating (A) Voltage drop (mv) Power loss (W) 50 A Derating table (A) SW60PV-DC Ambient temperature ( C) Rating A Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the SW60-DC protective devices to provide greater insulation of the terminal screws. b a Spacer clips 9 mm in each side to provide isolation. DB DB DB d 9 mm spacers must be used on both sides of the device to create a local ventilation space around the product. 9 mm mini 9 mm mini d Failure to match polarity during connection may lead to a fire hazard and/or serious injury. The connection polarity must be observed (marked on the front panel). Use only with direct current. 124 Version : /05/2015 CA901030E

15 DC main switch for photovoltaic installations Switch SW60-DC (cont.) Technical data (cont.) Weight (g) Switch disconnector Type SW60-DC 530 Dimensions (mm) DB Connection Without accessory With accessories 14 mm PZ2 6.5 mm Rating Tightening torque Copper cables UL 486A Rigids Flexibles with ferrule 50 mm 2 Cu/Al Terminal screw on connection for ring terminal Multi-cables terminal Rigid cables Flexible cables DB DB DB DB DB DB A 3.5 N.m 1 to 35 mm 2 1 to 25 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 CA901030E Version : /05/

16 DC main switch for photovoltaic installations e IEC / EN PB The is a direct current switch-disconnector dedicated to disconnection of the string of photovoltaic modules and the PV inverter. It is designed to isolate the string of photovoltaic modules and the inverter from the rest of the photovoltaic installation for maintenance operations in complete safety. The will be installed in a string PV protection enclosure close to the strings of photovoltaic modules. It can also be installed near the PV inverter. It can be locked (by a padlocking device) in OFF position to ensure safety during maintenance operations. the can switch a multi-directional current. Connection b The is not polarity sensitive: (+) and (-) wires can inversed without any risk. Isolation distance b The is delivered with three inter-pole barrier to provide increased isolation distance between two adjacent connectors Prewired b The cables crosssection is suitable b The tightening torque is mastered 126 Version : /05/2015 CA901043E

17 DC main switch for photovoltaic installations (cont.) Main characteristics Operating voltage (Ue) Rated insulation voltage (Ui) Rated operational current (Ie) Impulse voltage (Uimp) Permissible rated short-time withstand current (Icw) Rated short-circuit closing current (Icm) Electrical connection Number of poles 1000 V DC 1000 V DC 100 A 6 kv 1.5 ka / 500 ms 1 ka By the top for In and Out 2P Number of modules of 9 mm 12 Diagrams DB DB IN OUT IN IN OUT OUT Standards IEC EN Catalogue number Auxiliaries A9N61701 See modules CA and CA Additional technical data b Position contact indication - suitability for isolation according to IEC/EN standard. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Prewired product: Input / Output on the same side. Derating table (A) Endurance (O-C) Electrical 300 cycles Mechanical Degree of pollution 2 Category Tropicalisation Ambient temperature ( C) 20,000 cycles DC21B Temperature Operating -25 C to 70 C Storage -40 C to 85 C Relative humidity: 95 % at 55 C in accordance with IEC and GB standards Rating A CA901043E Version : /05/

18 DC main switch for photovoltaic installations (cont.) DB Upstream connection Without accessory With accessories 15 mm PZ2 6.5 mm Tightening torque DB Copper cables 50 mm 2 Cu/Al Rigids Flexibles Terminal with ferrule DB DB DB Screw on connection for ring terminal DB Multi-cables terminal Rigid cables Flexible cables 3.5 N.m 35 to 50 mm 2 25 to 35 mm 2 50 mm 2 Ø 5 mm 3 x 16 mm 2 3 x 10 mm 2 Downstream connection Prewired delivered product: Do not remove Moreover it is recommended to use: b a terminal Screw Shield snaps onto the front of the protective devices to provide greater insulation of the terminal screws b a Spacer clips 9 mm in each side to provide isolation. DB DB A9N27062 A9N mm mini 9 mm mini d Required: to have a 9 mm space isolation in each side" Weight (g) Dimensions (mm) Switch disconnector Type 910 DB Version : /05/2015 CA901043E

19 DC main switch for photovoltaic installations (cont.) Application diagram String PV protection enclosure DB Photovoltaic string modules Diagram with for current y 100 A PV Inverter protection enclosure PV Inverter * iprd 40r PV * iprd 40r PV *: 100 A/1000 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD24 CA901043E Version : /05/

20 Protection Load protection iprd-dc surge arresters Withdrawable surge arresters type 2 for photovoltaic applications e IEC T2 EN Type 2 UTE C T2 pren T2 PB iprd-dc direct current surge arresters are designed to protect against overvoltages due to a lightning strike: of the "DC" input to the inverter and of photovoltaic panels. It should be installed in a switchboard inside the building. If the switchboard is located outside, it must be weatherproof. Withdrawable iprd-dc surge arresters allow damaged cartridges to be replaced quickly. They offer remote reporting of the "cartridge must be changed" message. DB Catalogue numbers Internal diagram Imax (ka) Maximum discharge current L+/t L-/t L+/L- L+/t L-/t L+/LiPRD-DC40r 600PV In (ka) Nominal discharge current Up (kv) Protection level U CPV (V) (1) Maximum steady state voltage Width in module of 9 mm Cat. no A9L16434 DB iprd-dc40r 1000PV A9L16436 u PB PB Replacement cartridges Type Replacement cartridges for Cat. no. C PV iprd-dc40r 600PV A9L16683 C PV iprd-dc40r 1000PV A9L16692 C neutral PV iprd-dc40r 600PV A9L16690 CA903007E Version : /05/

21 Protection Load protection iprd-dc surge arresters Withdrawable surge arresters type 2 for photovoltaic applications (cont.) Connection DB mm 6.5 mm PZ2 Type Tightening torque Copper cables DB Rigid DB Flexible or with ferrule iprd-dc 2 N.m 2.5 to 25 mm to 16 mm 2 DB Generator Depending on the distance between the "generator" part and the "conversion" part, it may be necessary to install two surge arresters or more, to ensure protection of each of the two parts. 10 m iprd-dc 1 Generator Conversion iprd-dc 2 10 m iprd-dc 1 Conversion 314 Version : /05/2015 CA903007E

22 Protection Load protection iprd-dc surge arresters Withdrawable surge arresters type 2 for photovoltaic applications (cont.) DB DB DB IP20 IP40 Technical data Main characteristics Type of network Temps de réponse Short circuit current (I SCPV ) Isolated direct current < 25 ns 30 A Type of surge arresters Type 2 End-of-life indication mode Additional characteristics Circuit opened by integrated thermal disconnector Degree of protection Device only IP20 (IEC 60529) Device in modular IP40 enclosure Chocs IK03 End-of-life indication By the cartridges White Operational Red At end of life By the NO/NC remote indication contact 250 V AC / 0.25 A Operating temperature -25 C to +60 C Storage temperature -40 C to +85 C Tropicalization (IEC ) Treatment 2 (relative humidity of 95 % at 55 C) Weight (g) Surge arresters Type iprd-dc40r 600PV 400 iprd-dc40r 1000PV 400 Dimensions (mm) DB CA903007E Version : /05/

23 Protection Load protection surge arresters Withdrawable surge arresters type 2 for photovoltaic applications e DB UTE C T2 EN : 2013 T2 PB direct current surge arresters are designed to protect against overvoltages due to a lightning strike: of the "DC" input to the inverter and of photovoltaic panels. It should be installed in a switchboard inside the building. If the switchboard is located outside, it must be weatherproof. Withdrawable surge arresters allow damaged cartridges to be replaced quickly. The surge arrester base can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom They offer remote reporting of the "cartridge must be changed" message. DB Catalogue numbers Internal diagram I Total (ka) Total discharge current iprd 40r 800PV In (ka) Nominal discharge current Up (kv) Protection level L+/t, L-/t, L+/L- U CPV (V) (1) Maximum continuous operating voltage L+/t, L-/t, L+/L- Width in module of 9 mm Cat. no A9L40271 DB iprd 40r 1000PV A9L40281 u PB Replacement cartridges Type Replacement cartridges for Cat. no. C PV iprd 40r 800PV A9L40172 C PV iprd 40r 1000PV A9L Version : /05/2015 CA903009E

24 Protection Load protection surge arresters Withdrawable surge arresters type 2 for photovoltaic applications (cont.) Connection DB mm 6.5 mm PZ2 Type Tightening torque Copper cables DB Rigid DB Flexible or with ferrule 3.5 N.m 2.5 to 25 mm to 16 mm 2 DB Generator Depending on the distance between the "generator" part and the "conversion" part, it may be necessary to install two surge arresters or more, to ensure protection of each of the two parts. 10 m iprd-dc 1 Generator Conversion iprd-dc 2 10 m iprd-dc 1 Conversion CA903009E Version : /05/

25 Protection Load protection surge arresters Withdrawable surge arresters type 2 for photovoltaic applications Application diagram String PV protection enclosure DB Photovoltaic string modules Diagram with for current y 100 A PV Inverter protection enclosure PV Inverter * iprd 40r PV * iprd 40r PV *: 100 A/1000 V DC MN, MX, MNx, MNs, MX+OF, OF, SD, OF+SD/OF, OF+SD Version : /05/2015 CA903009E

26 Protection Load protection surge arresters Withdrawable surge arresters type 2 for photovoltaic applications (cont.) DB DB IP20 IP40 Technical data Main characteristics Type of network Maximum continuous operating voltage (U CPV ) Response time Permanent operating current (Ic) Short circuit current (I SCPV ) iprd 40r 800PV iprd 40r 1000PV Isolated direct current 800 V 1000 V < 25 ns < 1 ma 200 A Type of surge arresters Type 2 Ground residual current I PE (AC) End-of-life indication mode Additional characteristics Degree of protection (IEC 60529) Satisfactory operation indication I PE (DC) Circuit opened by integrated thermal disconnector Device only IP20 Device in modular IP40 enclosure Chocs IK03 By the cartridges White Operational Red Cartridge must be replaced By the NO/NC remote indication contact 250 V AC / 0.25 A Operating temperature -25 C to +60 C Storage temperature -40 C to +85 C Humidity range 5 % to 95 % Standards UTE C T2 EN : 2013 T2 Weight (g) Surge arresters Type iprd 40r 800PV 400 iprd 40r 1000PV 400 DB Dimensions (mm) DB CA903009E Version : /05/

27 Complementary technical information Photovoltaic Examples of installation architectures The examples of photovoltaic installation architectures presented in this document illustrate the use of direct current circuit breakers dedicated to protection of the modules and cables of the PV strings, to protect against overloads and short circuits. To ensure the safety of the photovoltaic installation it is necessary, in the cases described below, to combine the circuit breaker with other protective or fault detection devices on the DC side. Installation from 10 to 100 kw - Ue y 800 V DC In the case of a PV architecture without an earthed polarity on the DC side and with a PV inverter without galvanic isolation, it is necessary to: b protect each string of photovoltaic modules with a installed in the junction box near the PV modules b add a residual current device on the AC side of the PV inverter so that the latter trips as soon as an earth fault occurs on the DC side. Restarting will be possible only after eliminating the fault. DB Earthing systems Inverter Installation at DC end Insulation monitoring device TT TNS IT b b - Without integral transformer Without earthed polarity - Private domain PV PV modules protective modules enclosure DC protective enclosure Inverter AC protective enclosure idpn Vigi 2P Public domain idpn Vigi 2P isw 4P iquick PF 3P+N General control and protection device Production meter Consumption meter idpn Vigi 2P 740 Version : /05/2015 CA908035E

28 Complementary technical information Photovoltaic (cont.) Examples of installation architectures Installation from 10 to 100 kw - Ue y 800 V DC In the case of a PV architecture without an earthed polarity on the DC side and with a PV inverter or with galvanic isolation, it is necessary to: b protect each string of photovoltaic modules with a installed in the junction box near the PV modules; b occurs. Restarting will be possible only after eliminating the fault. DB Earthing systems Inverter Installation at DC end Insulation monitoring device TT TNS IT b b - With integral transformer Without earthed polarity b Private domain PV PV modules modules protective enclosure DC protective enclosure Inverter AC protective enclosure IMD IM20 ic60n 2P Public domain IMD IM20 ic60n 2P iid 3P+N 300 ma iquick PRD 3P+N General control and protection device Production meter Consumption meter ic60n 2P IMD IM20 CA908035E Version : /05/

29 Complementary technical information Photovoltaic (cont.) Examples of installation architectures Installation from 10 to 100 kw - Ue y 800 V DC In the case of a PV architecture with an earthed polarity on the DC side and with a PV inverter having galvanic isolation, it is necessary to: b protect each string of photovoltaic modules with a installed in the junction box near the PV modules b add a earth protection circuit breaker, with all poles in series, on the DC side of the PV inverter. PV inverter stoppage is actuated via an auxiliary contact combined with the earth protection circuit breaker. Polarity earthing and the protective device should not be implemented if the PV inverter already has an earthed polarity. Restarting will be possible only after eliminating the fault. DB Earthing systems Inverter Installation at DC end Insulation monitoring device TT TNS IT b b - With integral transformer Earthed polarity - Private domain PV PV modules modules protective enclosure DC protective enclosure Inverter AC protective enclosure ic60n 2P Public domain ic60n 2P iid 3P+N 300 ma iquick PRD 3P+N General control and protection device Production meter Consumption meter ic60n 2P Version : /05/2015 CA908035E

30 Complementary technical information Photovoltaic (cont.) Examples of installation architectures Installation > 100 kw - Ue y 800 V DC In the case of a PV architecture without an earthed polarity on the DC side and a central PV inverter having galvanic isolation, it is necessary to: b protect each string of photovoltaic modules with a installed in the protection cabinet for the PV strings located near the PV modules b fault and actuate stoppage of the PV inverter as soon as it occurs. Restarting will be possible only after eliminating the fault. DB Earthing systems Inverter Installation at DC end Insulation monitoring device TT TNS IT b b b With integral transformer Without earthed polarity b PV modules PV modules protective enclosure NSX NA DC-PV/ NSX NA DC-PV/ DC protective enclosure NSX80-200DC-PV NSX80-200DC-PV Compact NSX/ Masterpact IMD Inverter XM300 IM20PV AC protective enclosure IMD Compact NSX/ Masterpact (*) IM20 To LV/MV transformer iquick PRD/ iprd40 IT + NG125(*) 3P (*) if IT earthing system at AC end NSX NA DC-PV/ NSX80-200DC-PV NSX NA DC-PV/ NSX80-200DC-PV CA908035E Version : /05/

31 Complementary technical information Photovoltaic (cont.) Examples of installation architectures Installations > 100 kw - Ue y 800 V DC In the case of a PV architecture with an earthed polarity on the DC side and a central inverter having galvanic isolation and an IT earthing system on the AC side, it is necessary to: b protect each string of photovoltaic modules with a installed in the protection cabinet for the PV strings located near the PV modules b add a earth protection circuit breaker, with all poles in series, on the DC side of the PV inverter. PV inverter stoppage is actuated via an auxiliary contact combined with the earth protection circuit breaker. Polarity earthing and the protective device should not be implemented if the PV inverter already has an earthed polarity. If the Isc of the DC installation exceeds 1.5 ka, replace the earth protection circuit breaker with an NSX80 DC PV provided with a 16 A release. Restarting will be possible only after eliminating the fault. DB Earthing systems TT TNS IT - - b PV PV modules modules protective enclosure DC protective enclosure NSX80-200DC PV Inverter Installation at DC end Insulation monitoring device Without integral transformer Earthed polarity - NSX NA DC-PV/ NSX NA DC-PV/ NSX80-200DC PV Compact NSX/ Masterpact Inverter 10 A V AC protective enclosure Compact NSX/ Masterpact iprd40 IT + NG125 3P To LV/MV transformer NSX NA DC-PV/ NSX80-200DC PV + NSX NA DC-PV/ NSX80-200DC PV 744 Version : /05/2015 CA908035E

32 Complementary technical information Examples of using switch-disconnector Architectures 10 kw-100 kw grid-connected PV system (small buildings) Three-phase multi-input inverter without array box Typically, 10 kw to 36 kw grid-connected inverters with U OC MAX probably higher than 600 V (i.e. 800 V or 1000 V) and I SCTC < 125 A, I AC < 63 A. In this range of power, inverters usually have between 2 and 4 maximum power point tracking (MPPT) inputs, so the number of strings in the same DC sub-network is equal to one or two. There is no need for string protection. A PV main switch for each MPPT input is necessary. When an inverter is indoors, additional remote-controlled switches at DC cable entry point are recommended for emergency services. Q1 DB SPD Q2 SPD Inverter with or without galvanic isolation ic60 Vigi type B or SI To grid connection SPD Q1 Q2 Outdoor Indoor Needs String junction box Switchgears and control PV main switch Isolation (b) Switching (making and breaking rated current) DC21B (b) DC21B Control (a) (b) Schneider Electric offer "Q1" C60NA-DC + MX / MN or + MX / MN "Q2" INS PV or C60NA-DC or b v v CA908040E Version : /05/

33 Complementary technical information Examples of using switch-disconnector Architectures (cont.) 10 kw-100 kw grid-connected PV system (small buildings) Three-phase inverter with one array box Typically, 30 kw to 60 kw grid-connected inverters. U OC MAX is generally higher than 600 V (up to 1000 V), I SCTC does not exceed 200 A, I AC does not exceed 100 A. This design has more than 2 strings. Reverse current protection is therefore necessary. A main PV switch is required. When an inverter is inside, additional remote-controlled switches at DC cable entry point are recommended for emergencies. DB Q1 SPD Q2 SPD Inverter with or without galvanic isolation ic60 Vigi type B or SI SPD To grid connection Outdoor Indoor Needs String / Array junction box Switchgears and control PV array main switch Isolation (b) Switching (Making & breaking rated current) DC21B (b) DC21B Control (a) (b) Schneider Electric offer "Q0" TeSys DF "Q1" Compact NSX DC PV + MX / MN or + MX / MN "Q2" Compact NSX DC PV or b v v 746 Version : /05/2015 CA908040E

34 Complementary technical information Examples of using switch-disconnector Architectures (cont.) 10 kw-100 kw grid-connected PV system (small buildings) Three-phase inverter with two array boxes Typically, 60 kw to 100 kw grid-connected inverters with 2 arrays. Array cable protection is not necessary for 2 or 3 arrays. The I SCTC array y 200 A, I SCTC y 400 A, and I AC MAX y 200 A. A PV main switch is required close to the inverter. Remotely operated switches in array boxes allow disconnects to be located close to the PV modules in the event of emergencies. SPD DB Q1 Q1 Q2 SPD Inverter with or without galvanic isolation ic60 Vigi type B or SI SPD To grid connection Outdoor Indoor Needs String Array junction box Switchgears and control PV generator main switch Isolation (b) Switching (making and breaking rated current) DC22A (b) DC22A Control (a) (b) Schneider Electric offer "Q0" TeSys DF "Q1" "Q2" Compact NSX NA DC PV or or C60NA-DC or Compact NSX NA DC PV b v v CA908040E Version : /05/

35 Complementary technical information Examples of using switch-disconnector Architectures (cont.) 150 kw-500 kw grid-connected PV system (large buildings and farms) Multi three-phase inverter design without array box Typically, 10 x 20 to 20 x 30 kw grid-connected inverters. U OC MAX y 1000 V. One or two string per inverter. I AC MAX 50 A for one inverter. DB Q1 SPD Inverter with or without galvanic isolation ic60 Vigi type B or SI Compact NSX To grid connection SPD Q1 SPD Q1 Q1 Outoor Indoor String / Array junction box Needs Schneider Electric offer Switchgears and control "Q1" C60NA-DC or or SW60DC See 10 to 36 kw design Compact NSX with Micrologic trip unit ensures full selectivity with ic60 up to 40 A and offer advanced measurement and communication capabilities. 748 Version : /05/2015 CA908040E

C60H-DC C curve. Catalogue numbers

C60H-DC C curve. Catalogue numbers distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma... Contents Acti 9 MCBs, RCCB ic60h circuit breakers (curve B, C, D)... pages / to /4 ic60h and ic60h RCB0 10, 30 and 100 ma.... pages /5 to /8 Vigi ic60 add-on residual current devices.... pages /9 to /1

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering

More information

ic60a circuit breakers (curve C)

ic60a circuit breakers (curve C) (curve ) DB9 DB98 DB99 DB88 IE/EN 097- IE/EN 0898- ountry approval pictograms PB09-0 PB09-0 bb are multi-standard circuit breakers which combine the following functions: vvcircuit protection against short-circuit

More information

Influence of ambient temperature

Influence of ambient temperature temperature Devices Characteristics temperature Temperature Min. Max. DPN, C60H-DC, C60, C120, NG125, Tripping on overload -30 C +70 C C60PV-DC circuit breakers ik60 circuit breakers Tripping on overload

More information

Safe and reliable photovoltaic energy generation

Safe and reliable photovoltaic energy generation Safe and reliable photovoltaic energy generation Safe and reliable photovoltaic energy generation Selection of low voltage switchgears and circuit protection components per type of photovoltaic electrical

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011 Low Voltage Interpact Switch-disconnectors INS/INV40 to 2500 A Catalogue 2011 Interpact INS/INV Contents Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and

More information

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants devices Offers This page must be removed before publishing The Schneider Electric residual current devices range comprises various offers (A, B, C, D) so as to be as competitive as possible in each country,

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Railway application. Technical guide. Final distribution applications 05/2013

Railway application. Technical guide. Final distribution applications 05/2013 Railway application Technical guide Final distribution applications 05/2013 Contents 1 2 3 4 5 Railway application fields 5 Embedded equipment requirements 7 Fire risk 7 Environment 7 RoHS, REACH 7 Normative

More information

Circuit protection and control devices 0.5 to 6300 A

Circuit protection and control devices 0.5 to 6300 A Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps Protection Circuit breakers Panorama PB76_0.eps PB79_0.eps PB75_0.eps PB75_0.eps PB757_0.eps PB758_0.eps Circuit breakers C60 N0 Performance Number of poles P P P P P + N P + N Width (module 9 mm) 6 8

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCBO 6000 A Phase + Neutral, neutral right side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

MCBs and RCDs LR TM 6000

MCBs and RCDs LR TM 6000 MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A B and C curves residual current devices from 25 A to 63 A AC and A types ± ± ± ± MCBs Single pole 230/400 V± Single pole neutral 230 V± (1)

More information

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)

More information

CPG.0 Single busbar gas-insulated cubicles

CPG.0 Single busbar gas-insulated cubicles MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation

More information

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Btdin-RS RCBO 2p Phase + Neutral, neutral on right Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance

More information

DX³ RCBO 6000A Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Acti 9 the efficiency you deserve

Acti 9 the efficiency you deserve Low voltage Acti 9 the efficiency you deserve Catalogue 09/2013 Acti 9 Contents General Principle of catalogue numbers, protection (Acti 9) CA901009E 1 Circuit protection Choice of circuit protective devices

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Cascading & Discrimination

Cascading & Discrimination Cascading & Discrimination Typical LV System Level 1 ACBs - 6300A General LV Switchboard Level 2 ACB - 3200A MCCB 3200A Level 3 MCCB 1250A Fuses 630A Switchboard, Panelboard or MCC Level 4 MCBs - 100A

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Approvals (p. 906) 0 371 61 0 371 63 0 371 64 0 371 66 0 371 69 0 371 68 0 371 00 0 371 08 0 371 20 Connecting (p. 300) 1 connection - 1 entry/1 outlet ELECTRICAL FUNCTION TERMINAL BLOCKS INSULATION EQUIPOTENTIAL

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

R.C.B.O. SP / 1 module

R.C.B.O. SP / 1 module 87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45] Multi 9 System Catalog UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers Figure 46: UL 489/CSA C22.2 No.5 Listed C60 240 Vac Circuit Breaker with Box Lug Terminals Figure 47: UL 489/CSA C22.2 No.5 Listed

More information

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS FEATURES Robust, durable construction Unique double doors open 180 with minimum projection Light grey colour standard, can be painted to suit décor re quirements

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

Solar Installer Range. Bright solutions

Solar Installer Range. Bright solutions Solar Installer Range Bright solutions IMO is at the forefront of control component technology specifically developed for the renewable energy market and in particular solar energy. Whether meeting the

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 / 10 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

DC-Switch Disconnectors for Photovoltaic acc. to IEC

DC-Switch Disconnectors for Photovoltaic acc. to IEC DC-Switch Disconnectors for Photovoltaic acc. to IEC 60364-7-712 Ratings DC-Switch Disconnectors Rated current DC21B at U e I th open 4 poles in series Type A A V LS16 16 16 LS25 25 25 LS32 32 32 LS40

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

Electronic circuit breaker EBU10-T

Electronic circuit breaker EBU10-T Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

Mini DC - Isolators for Photovoltaic

Mini DC - Isolators for Photovoltaic Mini DC - Isolators for Photovoltaic acc. to IEC 60364-7-712 Quality made in D1024E171 Technical catalogues and news under: www.benedict.at Contactors Motor-Starter Mini-Contactors Contactors Overload

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

The effective choice The benefits of a product with the highest quality standards

The effective choice The benefits of a product with the highest quality standards The effective choice The benefits of a product with the highest quality standards Compact size for easy installation in small spaces and retrofitting of already existing facilities. Terminals designed

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

DX³ RCBO 6000A Phase + Neutral, neutral on right

DX³ RCBO 6000A Phase + Neutral, neutral on right 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information