SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

Size: px
Start display at page:

Download "SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:"

Transcription

1 SERIES D DISCONNECT SWITCHES 1 Amp 0 Amp 00 & 0 Volt Load Make/Load Break Positive Opening Compact Size Modular Construction Horse Power Rated Custom Versions Featuring: Auto Alignment Shaft Wide Handle Selection Addon Auxiliary Addon Power Poles Addon Neutral Bar Addon Neutral Pole Under Voltage Trip Option OTHER AVAILABLE ET PRODUCTS: CAM SWITCHES 00 AMP SERIES D DISCONNECTS Machine Safety Disconnect Option FEATURING HANDLESHAFT SELFALIGNING SYSTEM ELECTRICAL & ELECTRONIC CONTROLS, INC. 881 DANBURY ROAD BREWSTER, NY FAX info@eecontrols.com EE CONTROLS, LTD 17 STEWART COURT ORANGEVILLE, ONTARIO CANADA L9W Z FAX infoeecontrols@on.aibn.com 18

2 to 00 AMPS DISCONNECTS ELEKTRA PRODUCTS DISCONNECT SWITCHES 10 AMP / 4 POLE 11 AMP POLE Automatic handle shaft alignment (See page 201 for complete line of amp switches) UNDERVOLTAGE TRIP DISCONNECTS 0 1 AMP FOR MACHINE SAFETY (Pages ) CAM SWITCHES 0 AMP, up to pole, switching positions Custom Cam Switches Built to your Specs (See catalog section VN) 184

3 to 00 AMPS EMERGENCY DISCONNECTS MAIN DISCONNECTS SERIES D MOUNTING & OPERATOR INDEX PAGE OPTIONS Safety Standards 185 FRONT OPERATOR (SEE SELECTION TABLES) TYPE BE (ONE PADLOCK) TYPE D (THREE PADLOCK) MOUNTING TWO SCREW FOUR SCREW 0mm DRILLING 22mm (7/8 ) DRILLING IP 5 IP 5 Type BE Type D Defeatable Type Operator TYPE BY1 IP 7 Dust Tight / Hose Test / Rain Tight. NEMA 1, R,, 4X (IP 7) Padlockable Recommended for 4X Applications (non corrosive areas). Type BY1 (22MM MOUNT ONLY) Door interlock can be bypassed by technician for servicing NOTE: I ON OFF O STANDARD MARKINGS ALL AVAILABLE WITH SAFETY DOOR INTERLOCK BASE MOUNT OPTIONS Screw Mount, D05 TO D7 DIN RAIL Mount, D05 TO D5 Technical Specifications SERIES D 10 Amp Open Type, or 4 Pole, 10 Amp Amp 192 Accessories 19 Open Type, or 4 Pole, 00 Amp 194 Pole 195 Enclosed, 10 Amp 195,197 Dimensions UNDERVOLTAGE TRIP OPTION General Information Series F 17 Amp, 2 or Pole Series S 01A Open Type Enclosed 197 Dimensions 198 HEAVY DUTY CAM SWITCHES Series VN 00 Amp Multi Pole Multi Position See Bulletin VN FUSIBLE DISCONNECTS Dimensions

4 to 00 AMPS MAIN DISCONNECTS EMERGENCYOFF SWITCHES MOTOR DISCONNECTS TYPE D DISCONNECTS FULL LINE EMERGENCY / MAIN DISCONNECTS WITH UV TRIP DISCONNECTS 1 AMP THROUGH 0 AMP (00 VOLT) FLEXIBLE SHAFT ALIGNMENT POLE, 4POLE, POLE OPEN...ENCLOSED COMPLETE OPERATOR HANDLE SELECTIONS 0 AMP RED, YELLOW, FOR EMERGENCY DISCONNECTS BLACKGREY FOR MAIN MOTOR DISCONNECTS PADLOCK OFF WITH ONE OR THREE PADLOCKS FULL ACCESSORY PACKAGE FIELD KIT ACCESSORIES FOR SERIES D2 D7 AUXILIARY INTERLOCK OPTIONS 1 N.O., 1 N.C., 1 N.O. / 1 N.C., 2 N.O., 2 N.C. GROUND TERMINAL NEUTRAL TERMINAL SWITCH NEUTRAL (4th POLE) EXTRA AUXILIARIES 4th POLE SWITCH NEUTRAL NEMA 4X 18

5 to 00 AMPS EMERGENCY DISCONNECTS MAIN DISCONNECTS SAFETY STANDARDS REQUIREMENTS, DISCONNECTS OSHA LOCKOUT TAG OUT VDE 011 NFPA 79 (ANSI) UL/CSA THROUGH 0 AMP IEC INTERNATIONAL STANDARDS DECLARATION OF CONFORMITY IEC 204, IEC 947 EN EN NFPA79 (Also per ANSI and NEC) 1.2 Emergency stop devices 1.2. Actuators of emergency stop devices shall be colored RED. As far as a background exists behind the device actuator, it shall be colored YELLOW. OSHA INTERNATIONAL SPECIFICATIONS. IEC...EN, EUROPEAN NORM. EN PART 1 While the OSHA Lock Out Tag Out requirement is commonly understood, color is also specified Safety color code for marking physical hazards. (iii)...electrical switches which letter or other markings appear, used for emergency stopping of machinery shall be RED. The VDE specifications 011 part 1 apply to the electrical equipment of machines. They comply largely with the IEC publication 204. This standard includes the German version of the European standard EN part 1: From DIN VDE 011, types of switches result: Main Switch Emergency off Switch Each power supply must be provided with a handoperated main switch. This main switch must disconnect the machine from the power supply (e.g. for machine maintenence). It shall be designed as a switch disconnector according to EN to satisfy the exigencies of utilization category AC2B. It shall be handoperated and may have only one off and one on position. It shall have a visible isolation section or indication of switching position which can indicate the off position only if spacings according to EN 947 have been obtained between all contacts. If the main switch will not be used simultaneously as emergencyoff switch, it s handle shall NOT be red. For the main switch, black or grey handles are recommended. It shall be lockable in the off position (e.g. by using padlocks). The handle of the main switch shall be easy to reach and located between 0. and 1.9 m above the access level. The breaking ability must be sufficient to break at the same time the current of the largest motor of the machine at stall and the sum of the currents of all other motors and/or load circuits. Emergencyoff mechanisms must be provided for each work station, wherean emergencyoff might be required. They must engage automatically and be easy to reach. The contacts of handoperated emergencyoff mechanisms shall disconnect simultaneously. The operating elements shall be RED. The area behind the handles shall be colored YELLOW. Main Switch = Emergencyoff switch For some machines which do not require emergencyoff mechanisms the main switch may function as an emergencyoff mechanism. In this case and for such disconnecting mechanisms the colors of the operating elements have to be the same as for the emergencyoff mechanims. SAFETY REQUIREMENT UV TRIP DISCONNECTS For personal safety, OSHA, ANSI, IEC and European standards; all require protection against automatic restarting after main line voltage failure. VDE specifications 011/ European standard EN part 1, section are specific: If automatic restarting can cause a dangerous condition, damage to the machine or to the working process, such as an automatic restart of the machine has to be avoided through the release of the undervoltage safety mechanism. 187

6 to 00 AMPS INTERNATIONAL RATINGS Technical data as per UL/CSA, IEC 204, IEC 947, EN0 204, EN 0 947, VDE 011 EMERGENCY / MAIN DISCONNECTS Switch Size Rated interrupted current Iu A switch insert/ith under enclosure APPROVALS CANADA, USA, UL General use 00VAC max., phase ~ A Motor phase 208V hp 2V hp 4V hp 00V hp Motor 1phase 0V hp 2V hp Pilot Duty Auxiliary switch UL/CSA A00 D /2 1 1/2 A00 D A00 D2 / A00 D / A00 DK A00 D A00 D A00 D / A00 D A00 Rated insulating voltage III/ V EN Ui Rated impulse voltage rigidity III/ kv EN Uimp. Connectable Cross Sections mm 2 single resp. multistrand Fine wire with core end bush mm 2 (DIN 4 228) For enclosure execution mm 2 Shortcircuit protection, A max. fusible cutout (gl) Requirements for isolators V ~ complied with up to Switching capacity AC21A/B Load break switches Rated operating current Ie A 5 x x4 5 5 x4 /2 5 x10 / 5 x 1 4 x / 1 ) 4 x x 70 /10 4 x Rated operating voltage Ue V ~ AC2A/B Motor switches..4v, (main switches) ~kw AC Motor switches, for operational switching..4v ~kw Auxiliary switches/rated insulating V voltage (III/) Ui Rated impulse voltage rigidity (III/) Uimp. kv Thermal rated current Ith A AC Rated operating current e at A 210 / 4 / V Shortcircuit protection, A max. fusible cutout (gl) 5.5 /4/ /4/ 1 11 /4/ /4/ /4/ /4/ /4/ 1 90/75 75 /4/ /4/ 1 Connectable cross sections mm 2 single resp. multi strand Fine wire with core end bush mm 2 (DIN 4 228) Wire ranges, AWG 1 ) See ordering pages 2 ) With terminal lug / mcm 2/ mcm 188

7 to 00 AMPS Main switches Emergencyoff switches Maintenence switches Rating Data Pole D Disconnects with UV trip DL8 DL9 R1 R2 R R4 R5 R S1 S2 S S ) 1 ) 1 A00 A00 A00 A00 A00 A00 A00 A00 A00 A00 A00 A x2 2 ) 2x2 2 ) x2 2 ) 2x4x 2 2 ) 5 x 4 5 x 5 x 10 5 x 1 4 x 5 4 x //5 9//5 /4/ /4/ /4/ /4/ /4/ /4/ /4/ /4/ /4/ ) See ordering pages 2 ) With terminal lug 189

8 to 00 AMPS EMERGENCY DISCONNECTS MAIN DISCONNECTS SERIES D BASE MOUNT WITH 1 0A PADLOCKABLE OPEN TYPE SAFETY DOOR INTERLOCK 00 VOLT ON OFF FRONT PANEL DRILLING D05 5 BY1 Operator 22MM Hole Mounting POLE 8 Adjustable mounting depth as standard DIMENSIONS: See page 185. BY1 Operator Auxilaries on page 179. SIZE UNIT D05 D1 D2 D DK4 D4 D5 D D7 4 POLE D05 8 Adjustable mounting depth as standard D1 D2 D DK4 D4 D5 D D7 RATED CURRENT ITH AMPS UL/CSA GENERAL PURPOSE (INDUCTIVE) AMPS WITH BE OPERATOR (1 PADLOCK) E D05BE 1 SD* E D1BE 1 SD* E D2BE SD* E DBE SD* E DK4BE 4 SD* E D4BE 4 SD* E D5BE 4 SD* TYPE BY1 OPERATOR HANDLE OPTION To order, add BY in place of BE in catalog number. Add $10 List. Includes safety door interlock. Use on D05...D5 DEFEATABLE OPERATOR 8 T DEPTH DIMENSION is standard on units sized 10Amp with through the door safety interlock mechanism. E D054BE 1 SD* E D14BE 1 SD* E D24BE SD* E D4BE SD* E DK44BE 4 SD* E D44BE 4 SD* E D54BE 4 SD* $ $ WITH D OPERATOR ( PADLOCK) E D05D SD* E D1D SD* E D2D SD* E DD SD* E DK4D 4 SD* E D4D 4 SD* E D5D 4 SD* E DD 5 SD* E D7D 5 SD* E D054D SD* E D14D SD* E D24D SD* E D4D SD* E DK44D 4 SD* E D44D 4 SD* E D54D 4 SD* E D4D 5 SD* E D74D 5 SD* $ BY1 ORDERED SEPARATELY $5.00 List IP 7 Rated. Recommended for use on Type 1, R,, 4X Applications. TYPE BY1 Operator with Safety Door Interlock can be bypassed by qualified technician for servicing. TO ORDER: BY1*S1 = For sizes D05, D1, D2, D BY1*S2 = For sizes DK4, D4 & D5 (Relplace asterick with color suffix) Available in Black SS and RG Red/Yellow ONLY. Ordering separately BY1 includes patented misalign module, interlock key (for shaft) and bypass tool as standard. $ * SUFFIX: Add RG for RedYellow operator handle. Add SS for Black handle D type only. Add SI for BlackSilver operator BE handle. To substitute NONautoalignment safety door interlock for the autoalignment style, change SD in part# to SDV. Deduct: D1($) list D2($14) list D($20) list Catalog Number Code: SD Safety Door (Interlock Design) BE 1 padlock type D padlock type BY1 1 padlock type last digit in part number indicates faceplate size. Part # example: E D1BE 1 SDRG; SD = safety door interlock design, BE = 1 padlock type, 1 = size 1 face plate, RG = RedYellow handle. Discount Schedule ET

9 to 00 AMPS EMERGENCY DISCONNECTS MAIN DISCONNECTS SERIES D BASE MOUNT 1 0A FRONT MOUNT P O L E AMPS WITH BE OPERATOR E D05BE 1 BM* E D1BE 1 BM* E D2BE BM* E DBE BM* E DK4BE 4 BM* E D4BE 4 BM* E D5BE 4 BM* $ WITH D OPERATOR E D05D BM* E D1D BM* E D2D BM* E DD BM* E DK4D 4 BM* E D4D 4 BM* E D5D 4 BM* E DD 5 BM* E D7D 5 BM* $ WITH BE OPERATOR E D05BE 1 FM* E D1BE 1 FM* E D2BE FM* E DBE FM* E DK4BE 4 FM* E D4BE 4 FM* E D5BE 4 FM* $ WITH D OPERATOR E D05D FM* E D1D FM* E D2D FM* E DD FM* E DK4D 4 FM* E D4D 4 FM* E D5D 4 FM* E DD 5 FM* E D7D 5 FM* $ P O L E * SUFFIX: Add RG for RedYellow operator handle. Add SS for Black handle D type only. Add SI for BlackSilver operator BE handle. DIMENSIONS: See pages 201 Auxilaries on page 19 AMPS Pole (Size D1 Only) Deduct $10 from List Price P/N Example: Change to 2: E D1BE ( Pole) E DBE (2 Pole) E D054BE 1 BM* $55 E D054D BM* $2 E D054BE 1 FM* $5 E D054D FM* $ E D14BE 1 BM* E D24BE BM* E D4BE BM* E DK44BE 4 BM* E D44BE 4 BM* E D54BE 4 BM* E D14D BM* E D24D BM* E D4D BM* E DK44D 4 BM* E D44D 4 BM* E D54D 4 BM* E D4D 5 BM* E D74D 5 BM* E D14BE 1 FM* E D24BE FM* E D4BE FM* E DK44BE 4 FM* E D44BE 4 FM* E D54BE 4 FM* E D14D FM* E D24D FM* E D4D FM* E DK44D 4 FM* E D44D 4 FM* E D54D 4 FM* E D4D 5 FM* E D74D 5 FM* Discount Schedule ET Switch Size D1, D2, D D4, D5 D, D7 SHAFT EXTENSIONS Shaft Length* Catalog Number mm (7.87 in) EDSE5 5mm (.10 in) EDSE7 14mm (5.27 in) EDSE11 * Field cut the shaft to length List Price 1 20 SHAFT COUPLING ONLY SE5 E $ List SE7 E $8 SE11 E $10 191

10 to 00 AMPS EMERGENCY DISCONNECTS MAIN DISCONNECTS SERIES D 0 AMP 00 VOLT PADLOCKABLE ON OFF FRONT DRILLING 22mm, 7/8 SINGLE HOLE MOUNT OPTION 0.5mm Full size PB mount POLE SIZE UNIT RATED CURRENT ITH UL/CSA GENERAL PURPOSE AMPS (INDUCTIVE) AMPS WITH BE OPERATOR WITH D OPERATOR D1 E D1BE 1 SH* $0 E D1D 2 SH* $9 D2 E D2BE 2 SH* 88 E D2D 2 SH* 97 D E DBE 2 SH* 1 E DD 2 SH* 10 DK4 D4 D POLE D1 D2 D DK4 D4 D5 1 2 Pole (Size D1 Only) Deduct $10 from List Price P/N Example: Change to 2: E D1BE ( Pole) E DBE (2 Pole) 1 E D14BE 1 SH* E D24BE 2 SH* E D4BE 2 SH* $ E D14D 2 SH* E D24D 2 SH* E D4D 2 SH* $ ADAPTOR RING To convert standard 22mm switch (7/8 mounting) to full size 0.5mm #ED145 $0. list each * SUFFIX: Add RG for RedYellow operator handle. Add SS for Black handle D type only. Add SI for BlackSilver operator BE handle. DISCONNECT DESCRIPTION PLATE FITS ABOVE TYPE BE OR D OPERATORS 192 MAIN SWITCH MAIN SWITCH BRUSH SILVER WITH BLACK LETTERS YELLOW WITH BLACK LETTERS BLACK WITH WHITE LETTERS CATALOG NUMBER EDNP EDNP EDNP Standard marking add suffix: Main Switch (MS) OR Emergency off (EO). For special marking add $ List. Example: #EDNPS1 Dimensions: See page X 1mm (1.9 X 0. ) S1 $8 Y1 $8 B1 $8 LIST PRICE 5 X mm (2.5 X 0.8 ) S2 $9 Y2 $9 B2 $9 Discount Schedule ET

11 to 00 AMPS SERIES D2 D7 ACCESSORIES Replacement Operator Handles BE Type Front Mount, Base Mount Operators D Type Front Mount, Base Mount Operators BE Type Safety Door Provision D Type Safety Door Provision no interlock provisions no interlock provisions interlock provisions interlock provisions SIZE PART# LIST PART# LIST PART# LIST PART# LIST ED05ED1 E BE**S05 $19 E D**S1 $20 E BESD**S05 $ E DSD**S1 $7 ED2ED E BE**S1 $20 E D**S1 $20 E BESD**S1 $7 E DSD**S1 $7 EDK4ED5 E BE**S2 $2 E D**S2 $2 E BESD**S2 $47 E DSD**S2 $47 EDED7 E BE**S $ E D**S $ E BESD**S $2 E DSD**S $2 ** Replace Asterix with handle color suffix: RG for red/yellow operator handle SS for black handle (D type only) SI for black silver operator (BE type) Part# Example: Black BE operator E D1 with interlock provision: E BESDSIS1 One per side mounting Front mount: terminal screws accessible from the rear Rear mount: D2/D DK4/ D4/D5 D/D7 Element Functional Diagram L1T1, L2T2, LT NN 114, , 22 Size Discount Schedule ET Front mounting F Rear mounting PF Front mounting F Rear mounting PF Front mounting F Rear mounting PF terminal screws accessible from the front Ground PE terminal PE PE Amps EDNPE2 A $10 EDNPE24 $10 EDNPE 1A $17 EDNPE4 $17 0A EDNPE44 $44 EDNPE44 $ Additional Power Pole N terminal N N EDNPE21 $10 EDNPE22 $10 EDNPE1 $17 EDNPE2 $17 EDNPE4 $44 EDNPE4 $44 N N Neutral Switch EDNPE EDNPE2 EDNPE5 $27 EDNPE $27 EDNPE45 $90 EDNPE4 $90 Auxiliary Switch Amp 1NO 1NC 1 14 EDHF10 EDHC10 EDHF10 EDHC10 EDHF10 EDHC10 11 EDHF01 EDHC01 EDHF01 EDHC01 EDHF01 EDHC01 Auxiliary Switch A Ith 1NO + 1NC 2NO 2 NC 1 14 See page for Technical Data EDHF11 $ EDHC11 $ EDHF11 $ EDHC11 $ EDHF11 $ EDHC11 $ EDHF20 $ EDHC20 $ EDHF20 $ EDHC20 $ EDHF20 $ EDHC20 $ EDHF02 $ EDHC02 $ EDHF02 $ EDHC02 $ EDHF02 $ EDHC02 $

12 to 00 AMPS SERIES DL DISCONNECT SWITCHES 0 0 AMP SHAFT EXTENSION KITS D PART # 20 LENGTH L (mm) 00 LIST 0 International requirements: The type DL8 and DL9 disconnects comply with the reqiurements of DIN EB part 1 / VDE 011 section 5. for handoperated main switches. According to EN European Norm, the disconnects are also rated to comply with utilization category AC2B.( These are not UL Approved). Voltage rating: 0 Isolation Volts, DL series switches comply with the isolator requirements according to VDE for 0 V in phase systems. The connection terminals have individual terminals for connection to lugs or bus. The double lever type handle DHV is equipped with an interlocking for padlocks. pole or 4pole: The switches can also be supplied in 4pole execution as switching neutral. Operating handle red Face plate yellow RG Switch size Thermal rated current ITH A Catalog number Front Mounting F55 List Base mounting with door coupling and door interlock PVF55 DHV Catalog number List poles DL8 DL9 0 0 E DL8F 5 FM* E DL9F 5 FM* $298 $0 E DL8F 5 BM* E DL9F 5 BM* $298 $0 4poles DL8 DL9 0 0 E DL84F 5 FM* E DL94F 5 FM* $2917 $281 E DL84F 5 BM* E DL94F 5 BM* $2917 $281 SUFFIX: Add RG for RedYellow operator handle. Add SI for BlackSilver operator handle. DIMENSIONS: See page Discount Schedule ET

13 to 00 AMPS SERIES D ENCLOSED DISCONNECTS Maintenance switches D and DL series Construction features VOLT 1 0 AMP Type D4 AMP disconnect in Type S4 enclosure ENCLOSED DISCONNECTS SERIES D, AND DL ARE LOAD MAKE, LOAD BREAK DISCONNECTS FOR USE AS MAIN AND PANEL ONOFF DISCONNECTS, AND EMERGENCY (RED YELLOW) DISCONNECTS. SERIES D,, 4 OR POLE, 1 TO 0 AMP. SERIES DL, OR 4 POLE, 0 TO 0 AMP. VOLTAGE RATING ALL SERIES D DISCONNECTS ARE RATED VOLT MAXIMUM, OPERATING VOLTAGE. LOCK OUT / TAG OUT OPERATOR HANDLES ARE TYPE BE FOR ONE LOCKOFF OR TYPE D FOR PADLOCKS. ENCLOSURES SERIES D STANDARD ENCLOSURES ARE ALL IP5, TYPE S4, OIL TIGHT, WATER TIGHT, HOSE DOWN DESIGN WITH KNOCKOUTS, OR TYPE NEMA 4X. METAL NEMA 1 OR ARE ALSO AVAILABLE. NEMA IP 5 IS FOR INDUSTRIAL AND OUTDOOR APPLICATIONS AND IS CAPABLE OF HOSE TEST WATER TIGHTNESS. IP 5 IS USED INTERNATION ALLY FOR SIMILAR APPLICATIONS AS THE NEMA 4 OR 4X, WHEN NONCORROSIVE DESIGN IS REQUIRED. GROUND CONNECTION TERMINALS (PE) ARE STANDARD IN ALL ENCLOSURE SIZES. OPTIONAL ARE NEUTRAL CONNECTION (N) OR SWITCHING NEUTRAL (STANDARD 4 POLE DESIGN). 195

14 to 00 AMPS POLE DISCONNECTS SERIES D PADLOCKABLE OPEN TYPE 00 VOLT ONOFF FRONT PANEL DRILLING D17 See Dimensions Page 185. POLE SIZE UNIT D1 D2 I TH AMPS BASE MOUNT WITH SAFETY DOOR INTERLOCK With Auto Alignment RATED CURRENT WITH BE OPERATOR WITH D OPERATOR UL/CSA GENERAL PURPOSE (INDUCTIVE) AMPS CATALOG NUMBER Suitable for 1 PADLOCK E D1BE 1 SD8* E D2BE SD8* LIST PRICE $ CATALOG NUMBER Suitable for PADLOCKS E D1D SD8* E D2D SD8* 0 A LIST PRICE $ D E DBE SD8* 7 E DD SD8* 8 DK4 E DK4BE 4 SD8* 7 E DK4D 4 SD8* 419 D4 E D4BE 4 SD8* 42 E D4D 4 SD8* 48 D5 1 1 E D5BE 4 SD8* 42 E D5D 4 SD8* 474 D E DD 5 SD8* 10 D7 0 0 E D7D 5 SD8* 10 8 DEPTH DIMENSION is standard on sizes D05D7 with through the door safety interlock mechanism. * SUFFIX: Add RG for RedYellow operator handle. Add SS for Black handle D type only. Add SI for BlackSilver operator BE handle. DEDUCT For NonAuto Alignment To substitute NONAuto Alignment safety door interlock for the autoalignment style, change SD in part# to SDV. Deduct: D1($) list D2($14) list D($20) list Last digit in part number indicates face plate size. Part# Example: E D1BE 1 SD8RG; SD = safety door interlock design, BE = 1 padlock type, 1 = size 1 face plate, RG = RedYellow handle, 8 = 8 Depth Dimension, with shaft. DIMENSIONS: See page 199. CATALOG NUMBER CODE: SD Safety Door (Interlock Design) BE 1 padlock type D padlock type Base Mount Pole Available from stock with handle attached to switch. Type BE, D: IP 5: Dust Tight / Hose Test / Rain Tight NEMA 1, R,, 4X (IP 7): BY1 is IP 7 and recommended for 4X applications (non corrosive areas). Defeatable Operator for size D05 D5 Replace BE with BY, Add $10 List Front Mount Pole Available from stock. Handle mounts on Enclosure Front with switch mounted inside cover. Series D Switches, Pole, 4 Pole and 5 Pole are also available from stock! 19 Discount Schedule ET

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES DESIGN FEATURES Double break contacts Polycarbonate shroud for wired terminal protection included Excellent switching & high short circuit capacity Compact and reliable Easy installation Front, rear and

More information

DISCONNECT SWITCHES (16 TO 630 amp)

DISCONNECT SWITCHES (16 TO 630 amp) I DISCONNECT SWITCHES (16 TO 630 amp) Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We carry a complete line of UL approved, CSA listed, Disconnect

More information

TYPE LS-K CONTACTORS TECHNICAL SPECIFICATIONS

TYPE LS-K CONTACTORS TECHNICAL SPECIFICATIONS TYPE LSK CONTACTORS TECHNICAL SPECIFICATIONS LSK CONTACTORS FROM LS K TO LS K INTERNATIONAL RATINGS Type Style Rated insulation voltage Ui Rated impulse voltage Uimp kv Mechanical endurance AC operation

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

For many applications

For many applications Series 40 Amp Rugged and dependable 40 amp switches for industrial applications Sprecher + Schuh s rugged rotary cam switches are available for most control and load applications up to 40 amps. A well

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

LDisconnect Switches. Disconnect Switches

LDisconnect Switches. Disconnect Switches Disconnect Switches Disconnect Switches Series 7 - Motor Disconnect Switches up to 100A...2 Handles & Accessories...10 Series 7 Enclosed Disconnect Switches...14 Technical Information...20 Dimensions...22

More information

AC Switches: ML & MN Series DC Switches: MDC1A Series

AC Switches: ML & MN Series DC Switches: MDC1A Series AC Switches: ML & MN Series DC Switches: MDC1A Series Australian & New Zealand Distributor Leveltec Engineering Pty Ltd Gloucester P:+612 6558 9264 F:+612 6558 1002 Sydney P:+612 9299 5630 F:+612 6558

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

SWITCH DISCONNECTORS PLANET -SWITCH.

SWITCH DISCONNECTORS PLANET -SWITCH. SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout disconnects Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 3150A 30A 3000A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

JCAM SWITCHES. Model Ratings / Product Numbering System...J2 Technical Data...J3

JCAM SWITCHES. Model Ratings / Product Numbering System...J2 Technical Data...J3 Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We offer complete line of Cam Switches with as many as 24 switch contacts. Each contact has two fixed

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

Control and Load Switch Specifications Bulletin Number 194E, 194L

Control and Load Switch Specifications Bulletin Number 194E, 194L Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13

More information

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...

More information

What you need to know. Â Conformity to standards

What you need to know.  Conformity to standards SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Rotary Disconnect Switches, Bulletin 194R

Rotary Disconnect Switches, Bulletin 194R ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

PowerLine OS Switch Fuses A, 690V

PowerLine OS Switch Fuses A, 690V Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC. SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC CONTROL UNITS SWITCH DISCONNECTORS & CAM SWITCHES TOP-TECHNIC TOP-TECHNIC EMERGENCY STOP MAIN SWITCHES MAIN SWITCHES TOP-TECHNIC TOP-TECHNIC CAM SWITCHES FOR

More information

Solar Installer Range. Bright solutions

Solar Installer Range. Bright solutions Solar Installer Range Bright solutions IMO is at the forefront of control component technology specifically developed for the renewable energy market and in particular solar energy. Whether meeting the

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

Big performance in a small package

Big performance in a small package Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,

More information

Switch Disconnectors

Switch Disconnectors Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

PV DC Isolator Switches

PV DC Isolator Switches PV DC Isolator Switches BYS series is DC isolator swith for PV application. Comply with kinds of electrical stard. Rated current is A to 3A,Rated working voltage is 00V to 100V Moudle design can match

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects Low Voltage Switches Enclosed switches - eot Manual motor controllers and disconnects The next generation of enclosed switches General information The eot series of enclosed manual motor controllers are

More information