PV DC Isolator Switches

Size: px
Start display at page:

Download "PV DC Isolator Switches"

Transcription

1 PV DC Isolator Switches BYS series is DC isolator swith for PV application. Comply with kinds of electrical stard. Rated current is A to 3A,Rated working voltage is 00V to 100V Moudle design can match with many wire ways. Mounting:Stard Din Rail/Panel mounting/fix installtion Welcome to our website for more information:

2 BYS Series DC Isolator Switches Application BYS-3 DC isolator switch is applied to 1kw to 0kw PV systems. The enclosure protection degree is IP for outdoor installation. Feature Compact structure UV resistant, IP enclosure Non polarity Arcing time < 3ms "OFF" position Lockable IEC Stard 4P,P DC-1B Ui:100V/Uimp:kV Appearance Introduction Waterproof Plug IP Ingress Protection Sealed Plug Application Category Knob BE LOCKABLE Electrical Diagram Br ON OFF Uimp=kV Ui=100V Technical data Symbol Merit Unit Rated operational voltage (DC ) Ue V DC Rated operational current (DC ) Ie A DC Conventional free air thermal current Ith 3 A Rated impulse withst voltage Uimp kv Rated short-time withst current (1s) Icw Rated short-circuit making capacity Icm Ratedconditionalshort-circuitcurrent Stard Short Circuit Rating High-Fault Short Circuit Rating Insulationvoltage UtiizatincategoryDC Ui DC-1B 100 V of cycles of operation(with current) 3000 times (T is 00 times only) of cycles of operation(without current) 7000 of DC 4/ Methodofmountig Methodofoperatin Stard TH3-7. DIN rail mounting independentmanualoperation Knoboperationforce max. 1.4 TighteningtorqueterminalscrewsM4,min.-max.M4 Tighteningtorquepanelmountignut,min.-max. TighteningtorqueM3screwinthestardblackknob,min.-max. Ambienttemperatureallowedbetween Storagetemperatureallowedbetween Maximumrelativehumidity,withoutcondensationat0 C Pollutiondegree IP rating terminals to+70-40to+0 90 IP C C % 1

3 Wiring Diagram Contact Configuration DC-1B Rating 00V 00V 900V 1000V 100V 100V Poles in series of Strings Weight kg/pcs 0A 1 BYS-3-H A 3A 1A 10A A BYS A 40A 40A 3A 1A 4 1 BYS-3-4S A 40A 40A 3A 1A 4 1 BYS-3-4B A 3A 3A 3A 1A 4 1 BYS-3-4T A 3A 1A 10A A 3 BYS A 1 BYS-3-3H 1.0 3A 3A 3A 3A 3A 1 BYS-3-S 1.0 3A 3A 3A 3A 3A 1 BYS-3-B A 40A 40A 3 BYS-3-T 1.0 Switching Configurations 4Parlleled Output -pole Parlleled BYS-3 H 4 4S 4B 4T 3H S B T Contacts Wiring diagram Switching example Dimensions(mm) M1/0/ 47.0 M.0X M1/0/ 47.0 M.0X1.

4 BYS Series DC Isolator Switches Welcome to our website for more information: 3

5 BYS Series DC Isolator Switches Application BYS series DC isolator switch for PV system.rated current is A to 3A,Rated working voltage is 00V to 100V.oudle design can match with many wire ways.mounting:stard Din Rail/Panel mounting/fix installtion Br OFF Application Category Insulation voltage Rated impulse withst voltage Rated Current ON Certificate Symbol Knob Stard Code Uimp=kV Instruction BYS.1/ H Basic Designation Accessories Max Rated Current Polarity Configuration [PV MANUAL-DISCONNECT SWITCH] E490.1:Panel mounting.:din rail mounting 3A 4/H/4S/4T/4B /3H/S/T/B Technical data Parameter Rated operational voltage (DC ) Symbol Merit Unit Ue V DC Rated operational current (DC ) Ie A DC Conventional free air thermal current Ith 3 A Ratedimpulsewithstvoltage Uimp kv Ratedshort-timewithstcurrent(1s) Icw Ratedshort-circuitmakingcapacity Icm Ratedconditionalshort-circuitcurrent Stard Short Circuit Rating High-Fault Short Circuit Rating Insulationvoltage Ui 100 V UtiizatincategoryDC DC-1B of cycles of operation(with current) 3000 times (T is 00 times only) of cycles of operation(without current) 7000 of DC 1//3/4// Methodofmountig Methodofoperatin Knoboperationforce Panel mounting/stard TH3-7. DIN rail mounting independentmanualoperation max. 1.4 TighteningtorqueterminalscrewsM4,min.-max.M4 Tighteningtorquepanelmountignut,min.-max. TighteningtorqueM3screwinthestardblackknob,min.-max. Ambienttemperatureallowedbetween Storagetemperatureallowedbetween Maximumrelativehumidity,withoutcondensationat0 C Pollutiondegree IP rating terminals IP rating gl of the shaft in case of single hole panel mounting to+70-40to+0 90 IP0 IP C C % 4

6 BYS.1 DC Isolator Switches Panel Mounting Compact Structure Arcing time < 3ms Busbar Design, Easy Installation Flame-Retardant Modular Design Non polarity IEC Stard P,4P,P,P DC-1B/Ui:100V/Uimp:kV NAME 4X Hle [PV MANUAL-DISCONNECT SWITCH] E490 Welcome to our website for more information: Leading Manufacturer for PV Solution

7 Wiring Diagram Contact Configuration DC-1B Rating 00V 00V 900V 1000V 100V 100V UL Ratings UL0i 00V 00V 1000V Poles in series of Strings Weight kg/pcs 1A A A 4A 1 BYS A 0A 1A 1A A 3A A 1 BYS A 1A 13A 11A 9A 3A BYS A 4A 1 BYS.1-3-H 0. 3A 3A 1A 10A A 3A A BYS A 40A 40A 3A 1A 3A 3A 3A 4 1 BYS.1-3-4S 0. 40A 40A 40A 3A 1A 3A 3A 3A 4 1 BYS.1-3-4B 0. 3A 3A 3A 3A 1A 3A 3A 3A 4 1 BYS.1-3-4T 0. 3A 3A 1A 10A A 3A A 3 BYS A 0A 1 BYS.1-3-3H A 3A 3A 3A 3A 40A 40A 40A 1 BYS.1-3-S A 3A 3A 3A 3A 40A 40A 40A 1 BYS.1-3-B A 40A 40A 3A A 0A 3 BYS.1-3-T A 3A 0A 1A 10A A 3A A 4 BYS A A 4 1 BYS.1-3-4H

8 Switching Configurations 1-pole 3-pole 4Parlleled Output Part BYS BYS.1-3- BYS BYS.1-3-H BYS BYS.1-3-4S BYS.1-3-4B BYS.1-3-4T Contacts Wiring diagram Switching example -pole Parlleled -pole Parlleled Part BYS.1-3- BYS.1-3-3H BYS.1-3-S BYS.1-3-B BYS.1-3-T BYS.1-3- BYS.1-3-4H Contacts Wiring diagram Switching example Bus-barwire A Bus-barwire A forseriesparallelswitchingofcontacts Weight Bus-barwire A.9g/pc Bus-barwire B.9g/pc WIRING RATINGS Wires per pole Conductor material Wire size(awg) Wire size(mm²) Torque 1 Copper (Cu) 14 AWG- AWG, Stred.mm~10.0mm 1.N`m~1.N`m Dimensions(mm) M1.0X ± ± 0. 0 PANEL CUTOUT N is the number of layers in the switch 3.+(Nx10.)±1% Gasket 1.0 7

9 BYS. DC Isolator Switches Din Rail Mounting And Fixed Mounting Compact Structure Arcing Time < 3ms Busbar Design, Easy Installation Flame Resistance Modular Design Non polarity IEC Stard P, 4P, P,P DC-1B/Ui:100V/Uimp:kV [PV MANUAL-DISCONNECT SWITCH] E490 Welcome to our website for more information: Leading Manufacturer for PV Solution

10 Wiring Diagram Contact Configuration DC-1B Rating 00V 00V 900V 1000V 100V 100V UL Ratings UL0i 00V 00V 1000V Poles in series of Strings Weight kg/pcs A 0A 1A 1A A 3A A 1 BYS A 4A 1 BYS.-3-H 0. 3A 3A 1A 10A A 3A A BYS A 40A 40A 3A 1A 3A 3A 3A 4 1 BYS.-3-4S 0. 40A 40A 40A 3A 1A 3A 3A 3A 4 1 BYS.-3-4B 0. 3A 3A 3A 3A 1A 3A 3A 3A 4 1 BYS.-3-4T 0. 3A 3A 1A 10A A 3A A 3 BYS A 0A 1 BYS.-3-3H 0.3 3A 3A 3A 3A 3A 40A 40A 40A 1 BYS.-3-S 0.3 3A 3A 3A 3A 3A 40A 40A 40A 1 BYS.-3-B A 40A 40A 3A A 0A 3 BYS.-3-T A 3A 0A 1A 10A A 3A A 4 BYS A A 4 1 BYS.-3-4H

11 Switching Configurations 4Parlleled Output Part BYS.-3- BYS.-3-H BYS.-3-4 BYS.-3-4S BYS.-3-4B BYS.-3-4T Contacts Wiring diagram Switching example -pole Parlleled -pole Parlleled Part BYS.-3- BYS.-3-3H BYS.-3-S BYS.-3-B BYS.-3-T BYS.-3- BYS.-3-4H Contacts Wiring diagram Switching example Bus-barwire A Bus-barwire A forseriesparallelswitchingofcontacts Weight Bus-barwire A.9g/pc Bus-barwire B.9g/pc WIRING RATINGS Wires per pole Conductor material Wire size(awg) Wire size(mm²) Torque 1 Copper (Cu) 14 AWG- AWG, Stred.mm~10.0mm 1.N`m~1.N`m Dimensions(mm) M1.0X ± ± 0. 0 PANEL CUTOUT N is the number of layers in the switch 3+(Nx10.)±1%

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Changeover & Bypass Sw it ches

Changeover & Bypass Sw it ches Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

DC-Switch Disconnectors for Photovoltaic acc. to IEC

DC-Switch Disconnectors for Photovoltaic acc. to IEC DC-Switch Disconnectors for Photovoltaic acc. to IEC 60364-7-712 Ratings DC-Switch Disconnectors Rated current DC21B at U e I th open 4 poles in series Type A A V LS16 16 16 LS25 25 25 LS32 32 32 LS40

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Solar Installer Range. Bright solutions

Solar Installer Range. Bright solutions Solar Installer Range Bright solutions IMO is at the forefront of control component technology specifically developed for the renewable energy market and in particular solar energy. Whether meeting the

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

MANUALLY OPERATED CHANGEOVER SWITCHES

MANUALLY OPERATED CHANGEOVER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Cam switches 3. General 3. Complete switches. Ø 16 or Ø 22 hole fixing

Cam switches 3. General 3. Complete switches. Ø 16 or Ø 22 hole fixing General Cam switches Complete switches, A The range K cam switches ( A rating) comprises only complete switches. These products are more specifi cally designed for process control applications: b compact

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Mini DC - Isolators for Photovoltaic

Mini DC - Isolators for Photovoltaic Mini DC - Isolators for Photovoltaic acc. to IEC 60364-7-712 Quality made in D1024E171 Technical catalogues and news under: www.benedict.at Contactors Motor-Starter Mini-Contactors Contactors Overload

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX 70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring: SERIES D DISCONNECT SWITCHES 1 Amp 0 Amp 00 & 0 Volt Load Make/Load Break Positive Opening Compact Size Modular Construction Horse Power Rated Custom Versions Featuring: Auto Alignment Shaft Wide Handle

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Limit Switch - Prewired Type Metal Body

Limit Switch - Prewired Type Metal Body Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4 Busbar support 20 30 BBS-/1 BBS-/3 57 52 29 29 1 5 3 0 1 5 10 2 0 5 3 7, 5 6 0 6 0 6 0 6, 8 12 1 0, 5 7 5 1 2 5 2 4 0 20 30 18 BBS-/4 563 98,5 10 29 93,5 5 29 18 75 180 10,5 6,8 30 30 25 20 52,5 12 BBS-/3-16

More information

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Protection and Connection -disconnectors OTDC and OTDCP for photovoltaic applications -disconnectors OTDC and OTDCP for photovoltaic applications DC swi-disconnectors Premium performance for DC applications

More information

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes OTDC16...32U - Compact efficiency OTDC from 16 to 32 amperes offers various DC voltage ratings and a control

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

KATKO Safety Switches:

KATKO Safety Switches: KATKO Safety Switches: Reliability, Economy, Safety KATKO/2007.01/AL 1 KUM 16-25A Dimensions: Overall: 130,4 x 96,4 x 42,0 Mounting holes: 118,0 x 84,0 -Polycarbonate or ABS IP65 enclosure -Excellent UV

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

What you need to know. Â Conformity to standards

What you need to know.  Conformity to standards SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

Safety switches for hinged doors

Safety switches for hinged doors 4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88. Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66

More information

atalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:

atalog Welcome to ATO.com! Contact us...   Tel: (Toll-free) Website: atalog Welcome to.com! Contact us... Email: sales@ato.com Tel: +1 800-585-1519 (Toll-free) Website: ZMQ2E Series Dual Power Automatic Transfer Switch (ATS) Applications ZMQ2E dual auto transfer switch

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

C60H-DC C curve. Catalogue numbers

C60H-DC C curve. Catalogue numbers distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Cam Switch. Rish Cam 16A Rish Cam 32A Rish Cam 100A. Rish Cam 10A Rish Cam 25A Rish Cam 63A Rish Cam 200A. Rish Cam 6A Rish Cam 20A Rish Cam 40A

Cam Switch. Rish Cam 16A Rish Cam 32A Rish Cam 100A. Rish Cam 10A Rish Cam 25A Rish Cam 63A Rish Cam 200A. Rish Cam 6A Rish Cam 20A Rish Cam 40A Rishabh's New Rish Cam I,C,M &INS rotary cam Switches offer a complete range of cam switches for control, Instrumentation and motor starting applications, maximizing the benefits and optimizing your use

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems The Complete Range Easy mounting onto supporting rails Protection against accidental contact in the standart version Perforated versions for connections Drawing of the NH Fuse-Switch, 3-pole switching,

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011 Low Voltage Interpact Switch-disconnectors INS/INV40 to 2500 A Catalogue 2011 Interpact INS/INV Contents Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Microswitches MK series

Microswitches MK series Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications 2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information