1 Introducing the New WEG Series. The was developed according to IEC & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the panel. The has a range of 25 to 160Amps, panel or door mount options, and offers a variety of accessories. Standard Features Suitable as Motor Base or Door mounting options DIN or base mounted Through the door or direct mount handles Touch Safe IP20 Catalog Number Sequence Overview Mounting 25 B- 3 -H Amperage Ratings/ Accessories Door Mount- 25A, 40A, 63A, 80A, 100A, Panel Mount- 25A, 40A, 63A, 80A, 125A, 160A AP- Neutral Pole AC- Auxiliary Contact TS- Cover Current (A) Number of Poles Poles- 3 Mounting P- Panel Door Mount B- Base Mount Chart intended as reference only and not to create part numbers. Accessories H- Red/Yellow Handle, + Shaft (Base Mount) B- Black/Grey Handle, + Shaft (Base Mount) NA- Neutral Pole 1NO- Auxiliary Contact 1NC - Auxiliary Contact Handle Shaft (mm) Neutral Auxiliary contact Red/yellow Black/gray pole 1NO 1NC 1NO/1NC Panel door t 40 t 63 t Base 80 t Notes: t - Only available as part of the standard configuration. - Available as part of the standard configuration or it can be supplied separately. - Only available to be supplied separately. cover Relays Enclosed Overloads Contactors Motor Pushbuttons A B WEG Automation - Products and Solutions 73
2 Motor Contactors Overloads Relays Pushbuttons Enclosed for Panel Door Mounting Standard Configuration ( Switch + Handle Red/Yellow) Catalog Number Ith (A) Ie (A) AC21 (690 V) AC22 (690 V) AC23 (690 V) Poles List Price Multiplier 25 P-3 H $80 40 P-3 H $85 63 P-3 H $ P-3 H $ P-3 H $185 and Accessories Switch Catalog Number Ith (A) Ie (A) Poles List Price Multiplier AC21 (690 V) AC22 (690 V) AC23 (690 V) 25 P $53 40 P $58 63 P $ P $ P $158 Rotary Handle Catalog Number Switch Color List Price Multiplier H 40 P 25/40 Red/Yellow $27 H 100 P 63/80/100 Red/Yellow $30 H 40-P-B 25/40 Black/Gray $27 H 100-P-B 63/80/100 Black/Gray $30 Neutral Pole Catalog Number Switch Contact List Price Multiplier AP 25-P-1 NA 25 1 NO early make $42 AP 40-P-1 NA 40 1 NO early make $42 AP 63-P-1 NA 63 1 NO early make $49 AP 80-P-1 NA 80 1 NO early make $49 Auxiliary Contact Catalog Number Switch Contact List Price Multiplier AC-40 P 1NC 25/40 1NC $35 AC-40 P 1NO 25/40 1NO $35 AC-80 P 1NC 63/80 1NC $37 AC-80 P 1NO 63/80 1NO $37 Cover Catalog Number Switch Poles List Price Multiplier TS-40 P 25/40 $14 3 TS-80 B/P 63/80 $28 TS-100 P 1) $70 Note: 1) Necessary 2 pieces of TS-100P to cover 3 poles. cover to line or load side (1 piece supplied). A B ASK4WEG
3 Switch for Base Mounting (Screw or Din Rail) Standard Configuration ( Switch + Handle Red/Yellow + Shaft) Catalog Number Ith (A) Ie (A) Shaft length AC21 (690 V) AC22 (690 V) AC23 (690 V) (mm) Poles List Price Multiplier 25 B-3 H $96 40 B-3 H $ B-3 H $ B-3 H $ B-3 H $ B-3 H $490 and Accessories Catalog Number Ith (A) Ie (A) AC21 (690 V) AC22 (690 V) AC23 (690 V) 25 B Poles List Price Multiplier 40 B $59 63 B $ B $ B $ B $435 Rotary Handle + Shaft Catalog Number Switch Color Shaft (mm) List Price Mulitplier H 40 B 25/40 Red/Yellow 85 $42 H 80 B 63/80 Red/Yellow 85 $45 H 160 B 125/160 Red/Yellow 300 $65 H 40-B-B 25/40 Black/Gray 85 $42 H 80-B-B 63/80 Black/Gray 85 $45 Shaft Catalog Number Switch Length (mm) List Price Multiplier HS / $12 HS / $17 HS /80/ 125/ $20 HS /80/ 125/ $26 Neutral Pole Catalog Number Switch Contact List Price Multiplier AP 25-B-1 NA 25 1 NO early make $42 AP 40-B-1 NA 40 1 NO early make $42 AP 63-B-1 NA 63 1 NO early make $49 AP 80-B-1 NA 80 1 NO early make $49 Auxiliary Contact Catalog Number Switch Contact List Price Multiplier AC-40 B 1NC 25/40 1NC $35 AC-40 B 1NO 25/40 1NO $35 AC-80 B 1NC 63/80 1NC $37 AC-80 B 1NO 63/80 1NO $37 AC-160 B 1NONC 125/160 1NO/NC $70 $53 Relays Enclosed Overloads Contactors Motor Pushbuttons Cover Catalog Number Switch Poles List Price Multiplier TS-40 B 25/40 $16 TS-80 B/P 63/80 3 $32 TS-160 B 125/160 $78 Note: cover to line or load side (1 piece supplied). A B WEG Automation - Products and Solutions 75
4 Technical Data Motor Contactors Overloads Relays Pushbuttons Enclosed A B IEC characteristics Units Auxiliary contact Rated operating voltage U e V 690 Rated insulation voltage U i V Rated impulse withstand voltage U imp (sectionable) kv Rated thermal current Ith A Rated thermal current in enclosed I the A Frequency Hz 50/60 Rated operating current I e : alternate current AC-21A switching resistive loads 690 V A AC V-5 A AC-22A switching mixed resistive and inductive 500 V A DC V-0.44 A loads 690 V A V A/kW 25/7.5 32/10 63/20 80/25 70/22 125/30 160/45 - AC-23A periodic switching of 3 phase 400 V A/kW 25/15 32/ /28 75/42 67/37 125/55 160/75 - motors 3 poles 500 V A/kW 22/15 27/ /35 75/52 67/45 100/63 125/ V A/kW 16/15 20/ /25 32/31 38/37 80/75 100/ V A/kW 22/5.5 27/7.5 45/14 60/19 60/ AC3 starting of cage motors 3 phase 400 V A/kW 22/11 27/15 40/22 55/30 55/ (interruption while running) 3 poles 500 V A/kW 22/11 22/15 35/24 45/31 55/ V A/kW 16/11 16/15 22/21 25/24 32/ V A Rated interruption 400 V A ,000 1,280 - current AC-23A (cosfi 0.45) 500 V A V A Short circuit characteristics Rated short-time short circuit withstand current Icw (1s) A ,200 1,500 1,500 3,000 3,000 - Rated short circuit making capacity Icm A 1,500 1,500 2,200 2,800 2,840 4,500 4,500 - Conditional rated short circuit withstand current ka /5 10/ Fuse rating gg 500 V A V A /80 63/ UL 508 characteristics use 600 V ac A HD A600 ac Q600 dc Single phase 120 V ac HP (FLA) 1.5 (20) 2 (24) (34) poles 240 V ac HP (FLA) 3 (17) 5 (28) (50) Standard motors load 240 V ac HP (FLA) 7.5 (22) 10 (28) (28) 40 (104) 40 (104) - 3 phase 3 poles 480 V ac HP (FLA) 10 (14) 15 (21) (34) 100 (124) 100 (124) V ac HP (FLA) 15 (17) 20 (22) (32) 125 (125) 125 (125) - characteristics degree Handle EN 60529/UL 50 IP65 / Type 1-4-4X-NEMA 4X - s EN IP20 Material group EN II IIIa IIIa II Pollution grade EN Flammability UL 94 - V0 Ambient temperature Operation C Storage C Climate withstand IEC 68 part Hot damp IEC 68 part Unsetted hot damp Switching force (3 poles) Nm (7.1 lb.in.) 1 Nm (8.85 lb.in.) 1.5 Nm 2.6 (23 lb.in.) - Connections EN block caliber - - A6 A8 - - A2 screw - - M4 M5 M8 M8 M3.5 Tightening torque EN Nm 3 Nm 6 Nm 6 Nm 0.8 Nm - UL lb.in. (1.2 Nm) 32 lb.in. (3.6 Nm) 53 lb.in. (6Nm) 7.1 lb.in. Main terminal capacity - mm² Flexible conductors - AWG /0-6 3/ mm² Solid conductors - AWG /0-6 3/ Opening angles ASK4WEG
5 for Panel Door Mounting P-3 (1.77) B Pushbuttons A (0.94) 23, (1.87) 47, (2.06) 52, IN DIN mm MM EN50022) (EN Ø (2.64) 67 Ø67 (0.89) 22,522.5 (0.04) - (0.31) (1.4) (1.09) (1.65) (3.22) (1.59) 40.5 (2.68) 68, (2.91) 73, d=8 Ø=8 3.2 (0.13 ) Relays Enclosed Overloads Contactors Motor (0.94) 24 (0.89) Ø22.5 Ø 22.5 WEG Automation - Products and Solutions 77
6 P-3 (1.43) 36, (2.85) 72, Motor (1.28) 32, (3.22) 81, (2.56) Contactors Overloads Relays Pushbuttons Enclosed (1.4) (2.66) (2.02) PARAFUSO Screw 3,2X13 3.2x13 d=8 Ø=8 (0.14) Ø3.5 Ø 3.5 (1.42) / (1.89) Ø36 / Ø48 Ø 36 /Ø 48 Ø 10.5 (0.41) Ø10.5 A B PARAFUSO Screw 3X9,5 3x ASK4WEG
7 100P-3 (0.49) ,5 (3.25) ,5 A Pushbuttons (1.44) ) 90 (3.74) 95 (4.17) , (2.52) 64 (2.64) Ø Ø67 67 (0.04) - (0.16) (1.4) (2.95) 75 (3.38) ,8 d=8 Ø=8 (1.42) 36 (0.13) Ø Ø3.3 (1.42) 36 (0.41) Ø Ø10.5 Relays Enclosed Overloads Contactors Motor PARAFUSO Screw 3.2X13 3.2x13 PARAFUSO Screw 3x9.5 3X9.5 B WEG Automation - Products and Solutions 79
8 Auxiliary Contact AC P1NC / AC P1NO (1.5) 38 Motor Cover TS-40P (1.77) 45 (0.05) 1.2 1,2 Contactors Overloads Relays Pushbuttons Enclosed TS-80B-P (2.07) 52, TS-100P (1.56) 39, (0.66) 16, (1.1) 28 (0.67) 17 (1.11) 28, (0.66) 16, (0.59) (0.61) 15, (0.65) 16, (0.55) (0.69) 17, (1.11) (0.75) ,3 19 (0.55) 14 (0.69) 17, (1.63) 41, (1.73) (1.67) 42, A B ASK4WEG
9 for Base Mounting B-3 (0.17) Ø4.2 4,2 (1.77) 45 B A Pushbuttons (1.15) 29, (2.36) 60 (2.72) 69 (0.43) 11 (0.87) 22 (2.64) Ø Ø67 (2.93) 74, (0.2) 5 (0.04)-(0.31) (0.53) (2.37) (1.4) (3.74)-(5.98) max. max. (0.29) 7.3 (1.6) 40.6 d=8 Ø=8 (0.94) 24 (0.13) 3.2 (0.89) Ø Ø Relays Enclosed Overloads Contactors Motor WEG Automation - Products and Solutions 81
10 B-3 (0.18) Ø4.5 4,5 (2.07) ,5 (1.63) ,3 (3.25) ,5 (3.6) ,5 DIN mm (EN (EN50022) Motor (0.86) 21, (3.59) 91, Contactors Overloads Relays Pushbuttons Enclosed (2.64) Ø Ø67 67 (0.04)-(0.31) 1-8 (1.4) (0.93) 23.6 (4.45)-(6.72) max. max. (2.67) 67.8 (0.29) 7.3 (2.02) (0.2) 5 d=8 Ø=8 (0.94) (0.89) Ø22.5 Ø 22.5 (0.13) 3.2 A B ASK4WEG
11 B-3 (0.18) Ø4.5 4,5 (2.57) 65, (4.02) 102, (4.46) 113, Pushbuttons DIN - 35mm (EN50022) Ø 67 (2.01) 51, (2.64) Ø67 (1.01) ,6 (1.4) (0.04)-(0.16) 1-4 (5.71)-(16.36) max. 3,150 (3.15) max. (1.91) (3.15) 80 (0.11) 2.8 (0.22) 5.5 d=8 Ø=8 Relays Enclosed Overloads Contactors Motor PARAFUSO Screw Screw 3,2X13 3.2x13 PARAFUSO Screw Screw 3X9.5 3x9.5 A B WEG Automation - Products and Solutions 83
12 Auxiliary Contact AC B1NC / AC B1NO (1.31) ,3 Motor Cover TS-40B (0.53) 13, Contactors Overloads Relays Pushbuttons Enclosed (1.77) 45 TS-80B-P (2.07) ,5 TS-160B (2.56) (0.66) 16, (1.1) 28 (0.67) 17 (1.11) 28, (0.81) 20, (1.5) 38 (0.61) 15, (0.87) 22 (0.59) (0.55) (0.55) (0.69) (0.69) 17, , (0.88) (0.88) 22, ,4 (1.39) 35, (1.67) 42, (2.07) 52, A B ASK4WEG
UMBW-UL489 and UL1077 Listed
-UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationElectronic overload relays EF205 and EF370
Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationNon-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.
disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection
More informationLow Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays
CWB and RW27-2D IEC Contactors and Thermal Overload Contactors Overload A-2-800-ASK4WEG www.weg.net/us Contactors CWB CWB Features A-4 Catalog Number Format A-7 Accessories Overview A-8 Part Number List
More information70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX
70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationProduct index. 4 - Manual motor protectors. Phone: Fax: Web: -
Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type
More informationUL 508 Non-Fusible Disconnect Switches
UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.
More informationThermal Overload Relays - WEG RW Series, 2 Pole
International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be
More informationShort form catalogue. Motor protection & control
Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationProduct index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.
Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type
More informationDCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC
More informationProtection Equipment
Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection
More informationUL 508 Non-Fusible Disconnect Switches
UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationVB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated
VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationSwitch Disconnectors
Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles
More informationI r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.
DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationThermal overload relay TF65 and TF96
Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and
More informationMPW Series. MPW Catalog Number Sequence. Standard Features MPW U004
Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,
More informationAF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits
More informationMotors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB
Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature
More informationAF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More informationMotors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line
Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationPhone: Fax: Web: -
HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right
More informationDATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer
DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up
More informationNSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals
NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low
More informationKT4 Manual Motor Starter
KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one
More informationProtection Equipment. 5/2 Introduction
Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1
More informationProduct range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102
Overloadrelay,10-16A,1N/O+1N/C Partno. ZB12-16 Articleno. 290168 CatalogNo. XTOB016BC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Frame size ZB12 Phase-failure sensitivity IEC/EN 60947,
More informationThermal overload relay TF140DU and TF140DU-V1000
Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationApprobationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking
Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description
More informationLimit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.
Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with
More informationOverloadrelay,10-16A,1N/O+1N/C. Articleno
Overloadrelay,10-16A,1N/O+1N/C Partno. ZB32-16 Articleno. 278452 CatalogNo. XTOB016CC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Product range Accessories Accessories Overload relays
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationControl switch/load disconnect switch Series 8008
> s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationMotors Automation Energy Transmission & Distribution Coatings UBW. Molded-Case Circuit Breaker UL 489 Listed
Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed USA..07/2017 Molded-Case Circuit Breaker UL 489 Listed The WEG Series of Molded Case Circuit Breakers
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationSiemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage
SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440
More informationControls. CONTACTORS CWB Line (up to 40A)
Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel
More informationIdeal for use as a manual starter
Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact
More informationContactor Types CI 61-98
MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationSwitches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes
Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes OTDC16...32U - Compact efficiency OTDC from 16 to 32 amperes offers various DC voltage ratings and a control
More informationTechnical Information
-100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationTechnical Information
C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /
More informationBulletin 193-T1 Bimetallic Overload Relays
Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode
More informationApprovals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking
MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationApprovals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking
MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationApplication Mini Contactors for Motors and Resistive Loads
Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More informationKT4 Manual Motor Starters
s General Description...F99 Quick Selection Guide...F100 Accessories...F101 Contact Blocks...F101 Adapter Plates...F101 Release Modules...F102 Connecting Modules...F102 Mounting...F103 Enclosures...F103
More informationACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence
rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationControl and Load Switch Specifications Bulletin Number 194E, 194L
Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13
More informationCylindrical fuse-link
Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH
More informationGeneral technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name
Data sheet CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor
More informationControls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)
Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up
More information3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,
Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationProduct range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany
Makecontact,CageClamp,Front Partno. M22-CK10 Articleno. 216384 Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA, IEC Construction
More informationStar Series Motor protection & control
Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM
More informationContact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France
Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationZS4-SF1 Screw Clamp Terminal Block
Technical Datasheet 1SNK 161 011 D0201 ZS4-SF1 Screw Clamp Terminal Block Fuse Catalogue Page 1SNK 161 011 S0201 4 mm² 10 AWG 8 mm 0.315 in Spacing Features and Benefits 90 90 180 59.7 2.35" - Protect
More informationCapacitor Switching Contactors Type K3...-A, K3...-K
Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and
More informationUL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated
11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More information