LK Position Switches TECHNICAL DATASHEET.

Size: px
Start display at page:

Download "LK Position Switches TECHNICAL DATASHEET."

Transcription

1 LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN contact blocks available 46 actuators available Versions with stainless steel external parts Versions with gold-plated silver contacts Approvals General data Ambient temperature: 25 C +80 C Max. actuation frequency: 600 operating cycles 1 /hour Mechanical endurance: million operating cycles 1 Mounting position: any Safety parameters: B d :,000,00 for NC contacts Mechanical interlock, not coded: according to EN ISO 1 One operation cycle means two movements, one to close and one to open contacts, as defined in EN Cable cross section (flexible copper strands) C, C4: min. 1 x 0.4 mm 2 (1 x AWG ) max. 2 x 1.5 mm 2 (2 x AWG 16) Contact block C: min. 1 x 0.5 mm 2 (1 x AWG ) max. 2 x 1.5 mm 2 (2 x AWG 16) In conformity with standards: IEC , EN , EN , EN 04, IEC 604-1, EN 604-1, EN ISO 1, EN ISO 0, IEC 60529, EN 60529, UL 8, CSA.2 No.. Approvals: IEC , UL 8, CSA.2 No., GB In conformity with the requirements of: Low Voltage Directive 06/95/EC, Machinery Directive 06/42/EC and EMC Directive 04/8/EC. Positive contact opening in conformity with standards: IEC , EN Installation for safety applications: Use only switches marked with the symbol aside the product code. Always connect the safety circuit to the NC contacts (normally closed contacts: C11-C, C21-C or C1-C2) as stated in standard EN , encl. K, par. 2. Actuate the switch at least up to the positive opening travel shown in the travel diagrams. Operate the switch at least with the positive opening force, indicated between brackets below each article, aside the minimum force value. Electrical data Utilization category without connector Thermal current (Ith): A Rated insulation voltage (Ui): 0 Vac 600 Vdc 0 Vac 0 Vdc (contact blocks, 4) Rated impulse withstand voltage (U imp ): 6 kv 4 kv (contact block, 4) Conditional short circuit current: 00 A according to EN Protection against short circuits: type am fuse A 0 V Pollution degree: Alternating current: AC ( 60 Hz) Ue (V) Ie (A) Direct current: DC1 Ue (V) 5 2 Ie (A)

2 Characteristics approved by UL Utilization categories Q00 (69 VA, 5 2 Vdc) A600 ( VA, Vac) Data of housing, 4X indoor use only,, 1 For all contact blocks except C2 and C use 60 or 5 C copper (Cu) conductor, rigid or flexible, wire size AWG /. Terminal tightening torque of.1 lb in (0.8 Nm). For contact blocks C2 and C use 60 or 5 C copper (Cu) conductor, rigid or flexible, wire size AWG. Terminal tightening torque of lb in (1.4 Nm). In conformity with standard: UL 8, CSA.2 No.

3 Selection diagram A01 A08 A A02 AA2 AA4 A05 AA5 A0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket A A21 A25 A4 A A A69 A5 round rod, stainless steel square rod fiber glass rod porcelain roller WITH RESET A01-R A02-R A05-R A0-R A-R A0-R A1-R A51-R ACTUATORS CONTACT BLOCKS C C C4, slow action 1NO-1NC snap action slow action CONDUIT ENTRY Threaded conduit entry 16 M16x1.5 (standard) PG 11 With cable gland X for cables from Ø 5 to Ø mm X for cables Ø Ø mm product options accessory sold separately

4 AA A A-R A16 A A1 A A1 A6 roller roller roller roller roller Ø mm, Ø mm, Ø mm, Ø 11 mm Ø mm stainless steel stainless steel stainless steel external rubber gasket rope switch for signalling A0 A1 A51 A52 A54 A55 A56 A5 A8 adjustable lever adjustable safety lever without actuator LOOSE ACTUATORS A52-R A54-R A56-R A5-R A8-R without actuator Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. LK C A02 - R 1 G 16 X R2 H6 Housing technopolymer, one conduit entry LK Contact Blocks 1NO-1NC, snap action C, slow action C, slow action C4 Actuators short plunger A01 roller lever A02 angled roller lever A Reset without reset (standard) simultaneous reset simultaneous rest, increased force R RF R R2 R R25 R5 R26 R2 H6 Ambient Temp. -25 C +80 C (standard) - C +80 C Rollers standard roller stainless steel, Ø mm (for actuators AA4, A) stainless steel, Ø mm (for actuators AA2, A02, AA5, A05, A0, A1, A51, A52, A54, A55, A56, A5) stainless steel, Ø mm (for actuators A0, A1, A51, A52, A54, A55, A56, A5) technopolymer, Ø 5 mm (for actuators A0, A1, A51, A52, A54, A55, A56, A5) rubber, Ø mm (for actuators A0, A1, A51, A52, A54, A55, A56, A5) rubber, Ø mm (for actuators A51, A52, A54, A55, A56, A5) rubber, protruding, Ø mm External Metallic Parts zinc-plated steel (standard) stainless steel 1 Contact type silver contacts (standard) silver contacts with 1 µm gold coating (not for contact block 2) G Pre-installed Cable Glands without cable gland (standard) X cable gland for cables Ø 5 Ø mm X cable gland for cables Ø Ø mm Additional combinations possible. Contact Technical Support for information. Threaded Conduit Entry 16 M16x1.5 (standard) PG 11

5 Contact type: R = snap action L = slow action With external rubber gasket With external rubber gasket With Ø mm stainless steel roller on request 11,6 C R C L C4 L Ø 8 LKCA NO-1NC LKCA01-16 LKC4A LKCA NO-1NC LKCA02-16 LKC4A02-16 type 4 N (25 N ) LKCAA2-16 1NO-1NC LKCAA2-16 LKC4AA2-16 type 4. N (25 N ) 6,5 1 6,5 0,8 4,2x,2,2,2,2 LKCAA4-16 1NO-1NC LKCAA4-16 LKC4AA4-16 type 5 4. N (25 N ) 0,8 With external rubber gasket With external rubber gasket 2(29-5) (1-2) 2(29-5) (1-2) C R C L C4 L LKCA NO-1NC LKCA05-16 LKC4A05-16 type 4 N (25 N ) LKCAA5-16 1NO-1NC LKCAA5-16 LKC4AA5-16 type 4. N (25 N ) LKCA0-16 1NO-1NC LKCA0-16 LKC4A0-16 type 4 N (25 N ) group LKCAA-16 1NO-1NC LKCAA-16 LKC4AA-16 type N (25 N ) group With external rubber gasket Fixed only by threaded head in vertical position C R C L C4 L Ø LKCA NO-1NC LKCA08-16 LKC4A Mx1 LKCA-16 1NO-1NC LKCA-16 LKC4A-16 Ø M x1 LKCA-16 1NO-1NC LKCA-16 LKC4A-16 Ø M x1 LKCA1-16 1NO-1NC LKCA1-16 LKC4A

6 Contact type: R = snap action L = slow action Roller, Ø 11 mm, technopolymer Roller, Ø mm, stainless steel R C R C L C4 L LKCA-16 1NO-1NC LKCA-16 LKC4A-16 6 N (25 N ) LKCA-16 1NO-1NC LKCA-16 LKC4A LKCA-16R 1NO-1NC LKCA-16R LKC4A-16R LKCA NO-1NC LKCA16-16 LKC4A16-16 Fixed only by threaded head in vertical position With external rubber gasket With external rubber gasket With external rubber gasket Ø M x Ø Ø.5 C R C L C4 L 86 LKCA1-16 1NO-1NC LKCA1-16 LKC4A LKCA-16 1NO-1NC LKCA-16 LKC4A-16 1 m/s 6.5 LKCA NO-1NC LKCA21-16 LKC4A m/s 6.5 LKCA NO-1NC LKCA26-16 LKC4A m/s 0.1 Nm With Ø mm stainless steel roller on request Other rollers available. Square rod, x mm C R C L C4 L x LKCA0-16 1NO-1NC LKCA0-16 LKC4A LKCA1-16 1NO-1NC LKCA1-16 LKC4A xx LKCA-16 1NO-1NC LKCA-16 LKC4A m/s Ø LKCA4-16 1NO-1NC LKCA4-16 LKC4A m/s

7 Contact type: R = snap action L = slow action Round rod, Ø mm, stainless steel Other rollers available. Other rollers available. Porcelain roller C C C4 R L L øx LKCA-16 1NO-1NC LKCA-16 LKC m/s LKCA NO-1NC LKCA51-16 LKC4A LKCA NO-1NC LKCA52-16 LKC4A Ø LKCA NO-1NC LKCA5-16 LKC4A m/s 0.02 Nm (0.25 Nm ) group 6 Other rollers available. Other rollers available. Other rollers available. Other rollers available. C R C L C4 L LKCA NO-1NC LKCA54-16 LKC4A LKCA NO-1NC LKCA55-16 LKC4A LKCA NO-1NC LKCA56-16 LKC4A LKCA5-16 1NO-1NC LKCA5-16 LKC4A5-16 Fiber glass rod Rope switch for signalling Ø6x0 6.5 C R C L C4 L X.2 LKCA NO-1NC LKCA69-16 LKC4A m/s LKCA6-16 1NO-1NC LKCA6-16 LKC4A6-16 2NO 0.5 m/s initial N - final N group

8 IMO Precision Controls devices with fitted reset facility, and when reset allows the device to trip when actuator is operated. The new device is a block inserted between the switch body and the head, and could be rotated independently, and positioned in any of the possible four. This new device has following advantages: The reset device can be integrated into almost all standard actuator heads with snap action are no longer necessary because the tripping movement is made by the reset device itself The reset device can be rotated independently from the head for maximum flexibility during installation Two driving forces: standard and increased for applications with vibrations Mechanical endurance: 1 million operating cycles. Contact type: R = snap action L = slow action 2(29-5) (1-2) C L C4 L Ø8 4 LKCA01-R16 LKC4A01-R LKCA02-R16 LKC4A02-R16 type 4 N (25 N ) LKCA05-R16 LKC4A05-R16 type 4 N (25 N ) LKCA0-R16 LKC4A0-R16 type 2. group With Ø mm stainless steel roller on request With Ø mm stainless steel roller on request Other rollers available. Other rollers available C L C4 L LKCA-R16 LKC4A-R LKCA0-R16 LKC4A0-R Nm (0.25 Nm ) LKCA1-R16 LKC4A1-R Nm (0.25 Nm ) LKCA51-R16 LKC4A51-R Nm (0.25 Nm ) Other rollers available. Other rollers available. Other rollers available. Other rollers available C L C4 L LKCA52-R16 LKC4A52-R Nm (0.25 Nm ) LKCA54-R16 LKC4A54-R Nm (0.25 Nm ) LKCA56-R16 LKC4A56-R Nm (0.25 Nm ) LKCA5-R16 LKC4A5-R Nm (0.25 Nm )

9 Position switches with revolving lever without actuator Contact type: R = snap action L = slow action With manual reset knob IMPORTANT For safety applications: join only switches and actuators marked with symbol aside the product code. C R C L C4 L 6.5 LKCA8-16 1NO-1NC LKCA8-16 LKC4A M4 2 LKCA8-R16 LKC4A8-R Nm (0.25 Nm ) Increased actuating force The switch can be delivered with increased actuating force (option RI). Ideal for applications with vibrations. Actuators A01, A, A, A16 N A02, A05 6 N A0.5 N A0... A Nm Loose actuators IMPORTANT: These loose actuators can be used with items of series LR, LM, LX, LZ and LK only. Ø mm Ø mm Adjustable square rod, xx5 mm Flexible rod with pointed end Adjustable round rod Ø x5 mm Ø mm xx Ø x Ø6x Ø AC-CAE0 AC-CAE1 AC-CAE AC-CAE4 AC-CAE AC-CAE51 Ø mm Porcelain roller Ø mm Adjustable actuator with technopolymer roller Adjustable safety actuator with technopolymer roller Ø mm Adjustable fiber glass rod - 9 AC-CAE52 AC-CAE5 (2) CA-CAE54 AC-CAE55 AC-CAE56 AC-CAE5 AC-CAE69 - Actuator AC-CAE55 can only be used in safety applications if adjusted to its max. length, as shown in figure beside. If you need an adjustable lever for safety applications, use the adjustable safety lever AC-CAE56. - (2) The position switch obtained by assembling switch LK A8-16 (e.g. LKC5A8 16, LKC6A8 16 ) with actuator AC-CAE5 will not present the same travel diagrams and actuating forces as switch LK A5 J016ST (e.g. LKC5A5 J016, LKC6A5 J016ST ). - The actuator cannot be rotated to the inside because it will mechanically interfere with the switch head. 9

10 Special loose actuators IMPORTANT: These loose actuators can be used with items of series LR, LM, LX, LZ and LK only. Stainless steel rollers, Ø mm AC-CAE1-R AC-CAE51-R AC-CAE52-R AC-CAE54-R AC-CAE55-R AC-CAE56-R AC-CAE5-R s, Ø 5 mm AC-CAE1-R25 AC-CAE51-R25 AC-CAE52-R25 AC-CAE54-R25 AC-CAE55-R25 AC-CAE56-R25 AC-CAE5-R25 Rubber rollers, Ø mm AC-CAE1-R5 AC-CAE51-R5 AC-CAE52-R5 AC-CAE54-R5 AC-CAE55-R5 AC-CAE56-R5 AC-CAE5-R5 Rubber rollers, Ø mm Protruding rubber rollers, Ø mm AC-CAE51-R26 AC-CAE2-R26 AC-CAE54-R26 AC-CAE55-R26 AC-CAE56-R26 AC-CAE5-R AC-CAE55-R2 AC-CAE56-R2 Ref: LKSwitch16 Errors and omissions excepted. Subject to change without notice.

Position switches FC series

Position switches FC series A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

Switches with manual reset

Switches with manual reset Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

LR-LX-LK-LW Safety Switches with separate actuator

LR-LX-LK-LW Safety Switches with separate actuator LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

SFS-UFS Single Foot Switches

SFS-UFS Single Foot Switches SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes

More information

Microswitches MK series

Microswitches MK series Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with

More information

Safety switches for hinged doors

Safety switches for hinged doors 4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC

More information

Safety rope switch without reset for simple stop

Safety rope switch without reset for simple stop afety rope switch without reset for simple stop election diagram FP 4-M2 FD 4-M2 FL 4-M2 FR 4-M2 FM 4-M2 FX 4-M2 FZ 4-M2 ACTUATOR 9 ACTUATOR 9 0 CONTACT BLOCK 1 9 21 1NO+ FP FD FL FC 33 34 CONDUIT ENTRIE

More information

Safety switches for hinged doors

Safety switches for hinged doors 4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Single foot switches - PX and PA series

Single foot switches - PX and PA series Single foot switches - PX and PA series Description The PX and PA foot switches are traditional products of Pizzato Elettrica that have recorded a continuous growth and success in the market. Modified

More information

Single foot switches PX and PA series

Single foot switches PX and PA series A Single foot switches PX and PA series Selection diagram CARRYING ROD See page /10 ADDITIONAL METAL PROTECTION OPEN PROTECTIONS CLOSED PROTECTIONS PA PA 2 CONTACT BLOCKS COMBINATIONS 01 02 1NO+1NC snap

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46

More information

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR. Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog 3-4 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog -2 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb Article

More information

Microswitches MK series

Microswitches MK series D Microswitches MK series Introduction Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica (cross-reference at page

More information

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66

More information

Microswitches MK Series

Microswitches MK Series General purpose microswitches for heavier duty applications High precision snap action mechanism 16A 250V AC resistive rating (I th ) Wide range of actuator styles Screw terminals with self lifting plate

More information

Single foot switches PX and PA series

Single foot switches PX and PA series Single foot switches PX and PA series Technical data Housing Made of polymer glass-reinforced shock-proof thermoplastic resin with double insulation Bedplate with non-skid rubber feet. Actuation force:

More information

Microswitches M series

Microswitches M series Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Rope safety switches with reset for emergency stop

Rope safety switches with reset for emergency stop Rope safety switches with reset for emergency stop Description and technical data hese rope operated safety switches are installed on machines or conveyor belts, to activate the emergency stop of the machine

More information

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switches - Limit Type (PS21L) Metal Body IP66 Limit Switches - Limit Type (PS21L) Metal Body IP66 High mechanical resistance Degree of protection IP66 Zinc alloy (Zamack) or aluminium body Positive Opening Operation Minimum Actuation Force/Torque

More information

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Product Description They are developed in order to be used for following operations: For monitoring and protection of industrial machines,

More information

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65 Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum

More information

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Limit Switches - Limit Type (PS31L) Plastic Body IP65 Limit Switches - Limit Type (PSL) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Limit Switches - Limit Type (PS42L) Plastic Body IP65 Limit Switches - Limit Type (PS42L) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque

More information

Miniaturized limit switches

Miniaturized limit switches Miniaturized limit switches Selection diagram Actuators 04 0 06 Thermoplastic Bodies M3 Contact blocks NONC 1NO+1NC snap action Cable entry With screw 290 GENERAL CATALOGUE miniaturized limit switches

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Limit switches 3. Page 92. Page 92

Limit switches 3. Page 92. Page 92 Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards

More information

Limit Switch - Prewired Type Metal Body

Limit Switch - Prewired Type Metal Body Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation

More information

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN Safety Interlock Switches D4B- N D4BN Safety Limit Switch Snap-action contact with certified direct operation. mechanism (NC contacts only) added to enable contacts when faults occur, such as fused contacts.

More information

FOOT SWITCHES

FOOT SWITCHES - 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,

More information

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation Presentation Variable composition Spring-rod lever with thermoplastic end () Spring-rod lever, metal () Variable length thermoplastic roller lever () Round rod lever, thermoplastic, Ø mm L = mm () ZCK

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B G L LP LS Thermoplastic Body E0 I E20 I E40 I Contact blocks (standard) M20 ½ NPT 00 NO+NC snap action 0 NO+NC slow action 02 NO+NC slow action with

More information

Pre wired limit switches

Pre wired limit switches Pre wired limit switches Selection diagram Actuators A B B 9 BL Thermoplastic Bodies E7 I s NO+NC snap action NO+NC slow action Cable entry 4 or 5 pole PVC sheath cable (standard) M connector AMP connector

More information

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT OsiSense XC Basic Limit Switches XCMN, XCKN, XCNT Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com - www.stevenengineering.com Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com

More information

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

LS Series Limit Switches. Short Form Catalogue AC1300 ABB Short Form Catalogue LS Series Limit Switches AC ABB LS Series Limit Switches Foot Switches Contents Panorama... 2 Limit Switches - Plastic Casing and Metal Casing... 12 Safety Limit Switches - Plastic

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-N Series Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Safety Limit Switches

Safety Limit Switches Safety Limit Switches with separate actuator Z02: Snap action 2NC Y+Y 3 Bent key 4 Flat key 5 Bent key 6 Flat key 7 Shock absorbing bent key 8 Shock absorbing flat key 9 Adjustable joint key Z11: Snap

More information

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping) Safety-door Switch D4BS The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment CSM_D4BS_DS_E_6_1

More information

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X. Limit switches pre-wired 3mm & 35mm Metal & plastic casings Limit switches Description Plastic are made of reinforced UL-VO thermoplastic fiberglass, offering double insulation and protection

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-NSeries Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N conforms

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

Hinged Safety Door Switch

Hinged Safety Door Switch Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),

More information

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic Limit switches Selection diagram Actuators A A S B B 3 H G L LP LS Thermoplastic Body E I E2 I E4 I Contact blocks (standard) M2 ½ NPT NO+NC snap action NO+NC slow action 2 NO+NC slow action with overlapping

More information

Automation - Lift - Handling System - Atex

Automation - Lift - Handling System - Atex Automation Lift Handling System Atex GIOVENZANA INTERNATIONAL B.V.: AUTOMATION TECHNOLOGIES AUTOMATION The solutions offered by Giovenzana are the results of the market analysis of industrial electrical

More information

Manual Reset Limit Switch

Manual Reset Limit Switch Manual Reset Limit Switch A Series of Pull-reset Models Available Ideal for elevators (EN81), escalators (EN115), and conveyors. Positive opening mechanism insulation approved by TÜV and BIA. and double

More information

Pendant control stations 6

Pendant control stations 6 Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment

More information

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE SERIES Z/T23 Safety-Rated, Positive-Break Miniature DIN Limit Switches Features & Benefits Positive-Break NC contacts won t stick or weld shut. Watertight design meets IP washdown requirements. Rugged,

More information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the is removed. The is the same size as contact interlock switches (HS5B).

More information

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing Electromagnetic Safety Switch With Separated 1 Code Construction F E - Casing: P: Plastic casing Cable inlet: 5: 3 x (M20x1) Type of FEP: E: Electrical block ( b with excited ) M: Mechanical block ( b

More information

D4BS CSM_D4BS_DS_E_8_4

D4BS CSM_D4BS_DS_E_8_4 Safety-door Switch CSM DS_E_8_4 The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment

More information

General_technical_data Series

General_technical_data Series Indicator actuator 2 500 Hz: 5 g Pushbutton actuator Lens flat/level with front bezel: - Momentary max. 3 600/h - Maintain max. 1 800/h Lens flat/raised above front ring: - Momentary max. 3 600/h - Maintain

More information

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic Safety switches Selection diagram Actuators AB BB CB TB S5 SC Thermoplastic Bodies E0 I E20 I E0 I Contact blocks 0 NO+NC slow action 0 2NC slow action 08 2NC slow action (for pull-wire switches) Pg 3,5

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR Presentation type XCR b XCR v With head for rotary movement operators, spring return to off position contact actuation position per direction Page / v With head for rotary movement operators, stay put

More information

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 47.90 USD Main Range

More information

PRODUCT SPECIFICATION. Foot Switches. Series.

PRODUCT SPECIFICATION. Foot Switches. Series. PRODUCT SPECIFICATION Foot 46 Series www.wernerelektrik.com Foot Switch Structures...1 Technical Data...2 Model Number Structure - Foot...3 Dimensions...4 Precautions... Foot WERNERS are Rigorous and tough.

More information

Gross Automation (877)

Gross Automation (877) Limit Switches Carlo Gavazzi broadens its leading range of products for the industrial automation world, with the new and complete range of mechanical limit and safety switches. These robust switches provide

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch CSM DS_E_3_1 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The world's

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

D4NH CSM_D4NH_DS_E_7_1

D4NH CSM_D4NH_DS_E_7_1 Safety-door Hinge Switch D4NH CSM_D4NH_DS_E_7_1 Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Lineup includes three contact models with 2NC/1NO

More information

Safety-door Switch. Ordering Information

Safety-door Switch. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.

More information

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm Limit Switches casing, 3mm, 4mm & 6mm Description are made of aluminum alloy and have a degree of protection of IP 66 and UL type 4X. The casings come in 3 dimensions: LS3M, 3mm width. LS4M, 4mm width.

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches HS5D Miniature Interlock Switches Head Removal Detection Function for Safer Performance Clearwater Tech - Phone: 8094.04 - Fax: 8.368.04 - Web: www.clrwtr.com - Email: info@clrwtr.com New Generation Miniature

More information

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR Presentation For hoisting and material handling applications XCR b XCR v With head for rotary movement operators, spring return to off position 1 contact actuation position per direction Page 326/6 v With

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

General_technical_data Series

General_technical_data Series Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_4_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Safety-door Hinge Switch CSM DS_E_4_1 Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Note: Contact your sales representative for details on models

More information

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid HS1L Interlock Switches with Solenoid 3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuator as HS1E (actuator retention force 3000N) Six contacts in a compact housing

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications Safety Limit Switch Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications H Snap-action contact for accurate switching with safe operation via direct drive positive

More information

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11 2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Interlock Switches Key features: Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator 4 Safety switches with and separate Selection diagram VF KEYF20 VF KEYF21 VF KEYF22 VF KEYF28 CTUTORS HED TYPE ND WORKING PRINCIPE D locked with de-energized E locked with energized SIGNING ED B Z two

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information