1 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

2 The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice for your protection and control needs by offering a family of products that are: affordable, reliable, simple, and available Prisma ipm Switchboard The performance you need Easypact range is an excellent choice when tight construction and upgrade budgets create a challenge in meeting performance and protection specification. Easypact MVS ACB A cost-effective investment With simplicity of selection, ease of installation, specification, selection, purchasing and stocking Easypact family delivers unbeatable value through its life cycle Easypact CVS MCCB The quality you demand Designed and manufactured by Schneider Electric using advanced manufacturing methods and premium materials, Easypact range is designed to match your quality expectations and the needs of each project EasyPact TVS Contactor PM 1200 Power Meter

3 CONTENTS ACB Easypact MVS type N... Page 4 ACB Easypact MVS type H... Page 6 MCCB Easypact CVS 3P MCCB Easypact CVS 4P Contactor Easypact TVS... Page 8... Page Page 12 Thermal Overload Relay Easypact TVS... Page 13 Power Meter, Easymeter PM Page 14 Type Tested Switchboard Prisma ipm... Page 15

4 EasyPact MVS Air Circuit breaker IEC The easy choice for reliable performance Rated insulation voltage Ui: 1000V Impulse withstand voltage Uimp: 12kV Rated operating voltage Ue: 690VAC Suitable for isolation IEC Yes Degree of pollution IEC : 4 Type Rated current In (A) No. of pole Breaking capacity Icu (ka rms) Rated service breaking capacity Ics (ka rms) Rated short-time withstand current Icw (ka rms) at 40 0 C V 690V %Icu 1s V 690V 3s 440/690V Breaking time (ms) between tripping order and arc extinction Closing time (ms) Service life C/O cycles Mechanical With maintenance Without maintenance MVS800 N 800 Electrical at 440V Without maintenance Reference ordering and price (VND with VAT) - Fixed type 3P Trip unit ET2I MVS08N3MF2L (long time, instantaneous) 70,624,000 Reference ordering and price (VND with VAT) - Drawout type 3P Trip unit ET2I MVS08N3MW2L (long time, instantaneous) 97,058,000 Reference ordering and price (VND with VAT) - Fixed type 4P Trip unit ET2I MVS08N4MF2L (long time, instantaneous) 87,574,000 Reference ordering and price (VND with VAT) - Drawout type 4P Trip unit ET2I MVS08N4MW2L (long time, instantaneous) 120,352,000 Dimensions (mm) (HxWxD) Weight (kg) (approximate) Drawout Fixed Drawout Fixed 3P 4P 3P 4P 3P/4P 3P/4P 70/85 40/ Easypact MVS trip unit ET2I (standard protection) t tr Isd Overload protection Short-circuit protection Instantaneous 0 I Easypact MVS trip unit ET5I (selective protection) t tr Overload protection Short-circuit protection Short time Instantaneous Isd tsd li 0 I l 2 t on l 2 t off Easypact MVS trip unit ET6I (selective +earth fault protection) t tr Overload protection Short-circuit protection Short time Instantaneous Earth fault Isd tsd li 0 I l 2 t on l 2 t off 4

5 NEW MVS1000 MVS12 MVS1600 MVS2000 MVS20 MVS3200 MVS4000 N 1000 N 12 N 1600 N 2000 N 20 N 3200 N MVS10N3MF2L MVS12N3MF2L MVS16N3MF2L MVS20N3MF2L MVSN3MF2L MVS32N3MF2L MVS40N3MF2L 73,861,000 75,585,000 82,9,000 92,551, ,222, ,474, ,309,000 MVS10N3MW2L MVS12N3MW2L MVS16N3MW2L MVS20N3MW2L MVSN3MW2L MVS32N3MW2L MVS40N3MW2L 103,786, ,734, ,869, ,218, ,0, ,4, ,432,000 MVS10N4MF2L MVS12N4MF2L MVS16N4MF2L MVS20N4MF2L MVSN4MF2L MVS32N4MF2L MVS40N4MF2L 91,587,000 93,726, ,212, ,764, ,435, ,828,000 2,592,000 MVS10N4MW2L MVS12N4MW2L MVS16N4MW2L MVS20N4MW2L MVSN4MW2L MVS32N4MW2L MVS40N4MW2L 128,694, ,870, ,917, ,951, ,326,000 1,8,000 3,096, x 441 x x 556 x x 2 x x 537 x /120 60/80 Option accessories Reference Unit Price List (with VAT) Electrical accessories (220/240 V AC) /60Hz Gear motor (MCH) (fixed) (drawout) 21,607,000 MX, XF, MN Closing release (XF) MVS (fixed) MVS (drawout) 8,270,000 Opening release (MX) (fixed) (drawout) 8,270,000 Under voltage release (MN) (fixed) (drawout) 8,270,000 MCH MN delay unit Rr (adjustable) 382 5,329,000 5

6 EasyPact MVS Air Circuit breaker IEC The easy choice for reliable performance Rated insulation voltage Ui: 1000V Impulse withstand voltage Uimp: 12kV Rated operating voltage Ue: 690VAC Suitable for isolation IEC Yes Degree of pollution IEC : 4 Type Rated current In (A) No. of pole Breaking capacity Icu (ka rms) Rated service breaking capacity Ics (ka rms) Rated short-time withstand current Icw (ka rms) at 40 0 C V 690V %Icu 1s V 690V 2s 440/690V MVS800 H 800 Breaking time (ms) between tripping order and arc extinction Closing time (ms) Service life C/O cycles Mechanical Electrical at 440V With maintenance Without maintenance Without maintenance Reference ordering and Price (VND) with VAT Fixed - type 3P Trip unit ET2I MVS08H3MF2 (long time, instantaneous) 83,149,000 Reference ordering and Price (VND) with VAT- Drawout type 3P Trip unit ET2I MVS08H3MW2L (long time, instantaneous) 104,810,000 Reference ordering and Price (VND) with VAT- Fixed type 4P Trip unit ET2I MVS08H4MF2L (long time, instantaneous) 94,139,000 Reference ordering and Price (VND) with VAT- Drawout type 4P Trip unit ET2I MVS08H4MW2L (long time, instantaneous) 115,235,000 Dimensions (mm) (HxWxD) Weight (kg) (approximate) Drawout Fixed Drawout Fixed 3P 4P 3P 4P 3P/4P 3P/4P 70/85 40/ Easypact MVS trip unit ET2I (standard protection) t tr Isd Overload protection Short-circuit protection Instantaneous 0 I Easypact MVS trip unit ET5I (selective protection) t tr Overload protection Short-circuit protection Short time Instantaneous Isd tsd li 0 I l 2 t on l 2 t off Easypact MVS trip unit ET6I (selective +earth fault protection) t tr Overload protection Short-circuit protection Short time Instantaneous Earth fault Isd tsd li 0 I l 2 t on l 2 t off 6

7 NEW MVS1000 MVS12 MVS1600 MVS2000 MVS20 MVS3200 MVS4000 H 1000 H 12 H 1600 H 2000 H 20 H 3200 H MVS10H3MF2L MVS12H3MF2L MVS16H3MF2 MVS20H3MF2L MVSH3MF2L MVS32H3MF2L MVS40H3MF2L 84,829,000 86,885,000 89,575, ,064, ,521, ,703, ,315,000 MVS10H3MW2L MVS12H3MW2L MVS16H3MW2L MVS20H3MW2L MVSH3MW2L MVS32H3MW2L MVS40H3MW2L 105,417, ,462, ,237, ,486,000 1,185, ,709, ,943,000 MVS10H4MF2L MVS12H4MF2L MVS16H4MF2L MVS20H4MF2L MVSH4MF2L MVS32H4MF2L MVS40H4MF2L 98,613, ,813, ,882, ,397, ,595, ,330,000 3,061,000 MVS10H4MW2L MVS12H4MW2L MVS16H4MW2L MVS20H4MW2L MVSH4MW2L MVS32H4MW2L MVS40H4MW2L 117,646, ,9, ,289, ,795, ,983, ,891, ,169, x 441 x x 556 x x 2 x x 537 x /120 60/80 Option accessories Reference Unit Price List (with VAT) Electrical accessories (220/240 V AC) /60Hz Gear motor (MCH) (fixed) (drawout) 21,607,000 MX, XF, MN Closing release (XF) MVS (fixed) MVS (drawout) 8,270,000 Opening release (MX) (fixed) (drawout) 8,270,000 Under voltage release (MN) (fixed) (drawout) 8,270,000 MCH MN delay unit Rr (adjustable) 382 5,329,000 7

8 Easypact CVS Moulded case circuit breaker IEC The easy choice for quality and value Adjustable trip unit from 0.7 to 1 x In Icu=Ics= Rated insulation voltage Ui: 690V Impulse withstand voltage Uimp: 8kV Rated operating voltage Ue: 440VAC Suitable for isolation IEC Yes Degree of pollution IEC : 3 Utilisation category: A Type Rated current No. of pole Breaking capacity Icu (ka rms) Trip unit Durability C/O cycles In at 40 0 C 220/240V 380/415V CVS100 B F Mechanical Electrical at 415V In/2 In Reference ordering and price list (VND with VAT) - Fixed type 3P Rated current In LV A 2,460,000 A LV ,460,000 32A LV ,460,000 40A LV ,460,000 A LV ,460,000 63A LV ,460,00 80A LV ,487, A LV ,487,000 1A 160A 200A 2A 320A 400A 0A Dimensions (mm) Fixed, front connections (WxHxD) 600A 3P 105 x 161 x 86 Weight (kg) Fixed, front 3P 1.8 TM-D thermal-magnetic trip units A Im A TM 600D 600A/40 0 C Im 8

9 NEW CVS160 CVS2 CVS400 CVS630 B F B F F N F N LV ,554,000 LV ,554,000 LV ,554,000 LV ,554,000 LV ,554,000 LV ,554,000 LV5103 2,649,000 LV ,649,000 LV ,145,000 LV ,406,000 LV ,997,000 LV ,304,000 LV5302 4,670,000 LV5332 5,274,000 LV5303 5,232,000 LV5333 5,891,000 LV ,987,000 LV ,933,000 LV ,460,000 LV ,643,000 LV ,298,000 LV ,190,000 LV ,190,000 LV ,4, x 161 x x 161 x x 5 x x 5 x Thermal-magnetic trip units TM16D to 2D TM320D to 600D Ratings (A) Magnetic protection (1) In at 40 O C Pick-up (A) accuracy+20% Im CVS100 CVS160/2 CVS400 CVS630 fixed adjustable 1600 to 3200 (320A), 2000 to 4000 (400A) 20 to 00 9

10 Easypact CVS Moulded case circuit breaker IEC The easy choice for quality and value Adjustable trip unit from 0.7 to 1 x In Icu=Ics= Rated insulation voltage Ui: 690V Impulse withstand voltage Uimp: 8kV Rated operating voltage Ue: 440VAC Suitable for isolation IEC Yes Degree of pollution IEC : 3 Utilisation category: A Type Rated current No. of pole Breaking capacity Icu (ka rms) Trip unit Durability C/O cycles In at 40 0 C 220/240V 380/415V Mechanical Electrical at 415V CVS100 B F In/2 In Reference ordering and price list (VND with VAT) - Fixed type 4P Rated current In LV A 3,287,000 A LV ,287,000 32A LV ,287,000 40A LV ,287,000 A LV ,287,000 63A LV ,287,000 80A LV ,477, A LV ,477,000 1A 160A 200A 2A 320A 400A 0A Dimensions (mm) Fixed, front connections (WxHxD) 600A 4P 140 x 161 x 86 Weight (kg) Fixed, front 4P 2.2 TM-D thermal-magnetic trip units A Im A TM 600D 600A/40 0 C Im 10

11 NEW CVS160 CVS2 CVS400 CVS630 B F B F F N F N LV ,548,000 LV ,548,000 LV5103 3,548,000 LV ,548,000 LV ,548,000 LV ,548,000 LV ,784,000 LV ,784,000 LV ,730,000 LV5163 4,974,000 LV ,383,000 LV ,851,000 LV5312 6,460,000 LV53 7,3,000 LV5313 7,323,000 LV5343 8,321,000 LV ,406,000 LV ,5300 LV ,589,000 LV ,244,000 LV ,373,000 LV ,555,000 LV ,319,000 LV ,974, x 161 x x 161 x x 5 x x 5 x Thermal-magnetic trip units TM16D to 2D TM320D to 600D Ratings (A) Magnetic protection (1) In at 40 O C Pick-up (A) accuracy+20% Im CVS100 CVS160/2 CVS400 CVS630 fixed adjustable 1600 to 3200 (320A), 2000 to 4000 (400A) 20 to 00 11

12 Easypact TVS Conforming to standards IEC , IEC Contactor Rated operational current Auxiliary built in contact References Price NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NC+1NO LC1E0910 LC1E0901 LC1E1210 LC1E1201 LC1E1810 LC1E1801 LC1E10 LC1E21 LC1E3210 LC1E3201 LC1E3810 LC1E3801 LC1E40 272, , , , , , , , , , , , ,000 1NC+1NO LC1E 1,017,000 1NC+1NO LC1E 1,148, NC+1NO LC1E80 1,419, NC+1NO LC1E95 1,786, NC+1NO LC1E120 2,188, NC+1NO LC1E160 4,849, LC1E200 5,215,000 2 LC1E2 7,9, LC1E300 8,846,000 Coil voltage code (Hz) Coil voltage Hz B5 E5 F5 M5 U5 Q5 N5 R5 Example: You need a 32 A contactor, 1 NC auxiliary contact, 24 V - Hz coil => LC1E3201B5 Accessories for LC1E contactor LAETSD Time delay auxiliary contact blocks for connection by screw clamp terminals 8 A V Clip-on mounting Front Description ON DELAY 1NO + 1NC - 30 Reference Price LAETSD 894,000 LAEN22 Instantaneous auxiliary contact screw lamps terminals Clip-on mounting Front Front Front Front Number of contacts 1 NC 1NO + 1NC 2NO 2NO + 2NC 12

13 Easypact TVS Thermal Overload relay Possible Imax Calibration Compatible with Contactor (size 1 & 2) Com. Reference E12 - E38 E18 - E38 E - E38 E - E38 E38 E40 - E95 E40 - E95 E40 - E95 E - E95 E - E95 E80 - E95 E80 - E95 E95 References PriceList 2013 LRE01 LRE02 LRE03 LRE04 LRE05 LRE06 LRE07 LRE08 LRE10 LRE12 LRE14 LRE16 LRE21 LRE22 LRE32 LRE35 LRE ,000 LRE ,000 LRE ,000 LRE ,000 LRE ,000 LRE1 564,000 LRE3 1,690,000 LRE3 1,690,000 blocks for connection by Mechanical Interlock Price list 2013 Reference Price list 2013 LAEN02 81,000 LAEN11 81,000 LAEN20 81,000 Using 2 identical contactors LC1E09 / E LC1E80 / E95 LC1E120 / E160 Reference LAEM1 LAEM4 LAEM5 68, , ,000 LAEN22 162,000 LAEM1 13

14 PM1200 Power Meter The PowerLogic PM1000 series power meters are easy-to-use, cose-effective meters that offer the basic measurement capabilities required to monitor an electrical installation. Charaterized by their rugged construction, compact size and low installation costs, these state-of-the-art multi-function meters are ideal for control panels, motor control centers and genset panels. Applications Power monitoring operations Load studies and circuit optimization Equipment monitoring Meter s outputs can be used by control devices Preventative maintenance Main characteristics Accurate metering The meter conforms to accuracly class 1.0 as per IEC and IEC Easy-to-read display The bright alphanumeric, 15mm-high LED display provides three lines for measurement valubes with four digits per line. The display auto-scales for Kito, Mega and Giga valubes. Auto scrolling mode allows for easy reading. Analog load bar The color-coded analog load bar indicates the percentage of load through 12 LED segments. Turbo Key access to information The Turbo Key button lets you access the mose commonly viewed parameters or enter setup mode with a single push of the button. Quick and easy installation Setup is done through the front panel keys. Quick entry to setup during power up by TURBO key. Direct connection for metering voltage inputs up to 480 Vac L-L Color-keyed terminal board labeling The color-keyed label on the terminal board helps ensure accurate wining Secure settings Commecial reference METSEPM1200 Description PM1200 power meter with RS485 communication Unit Price List (with VAT) Currency 11,0,000 VND 14

15 Innovate with the Prisma ipm solution Prisma ipm: fully IEC-compliant A proven solution Using our Prisma ipm solution, you can easily design, implement and operate LV electrical distribution and control switchboards that are dependable, because they are optimized, tested and compliant with the IEC standard. 100 % quality Electrical characteristic Nominal rated current (A) Rated insulation voltage Ui (VAC) Rated operation voltage (VAC) Rated impulse withstand voltage (KV) Frequency (Hz) Main busbar rated current max. Ie (A) Rated short-time withstand current Icw (KA/1s) Rated peak withstand current Ipk (KA) Mechanical characteristics Overall height (mm) Number of vertical modules (functional height) 1 module = mm Dept (mm) Width of enclosure for devices (mm) Width of busbar duct (mm) Width of cable duct (mm) Partitioning IP IK Color Applicable standards Type test IP class Insulation material inside the enclosures System L / /31/40/54 07/08/10 RAL 7047 (enclosure) and RAL 9022 (functional unit) IEC IEC60529 IEC System M up to 4000A / / /600 (front access), 800/1000 (rear access) 600 and (in 800 wide enclosure) 300 Form 1, 2, 3b and 4b 30/31/54 07/08/10 RAL 7047 (enclosure) and RAL 9022 (functional unit) IEC IEC60529 IEC

16 16

17 17

18 18 NOTES:

19 July 2013

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Cascading & Discrimination

Cascading & Discrimination Cascading & Discrimination Typical LV System Level 1 ACBs - 6300A General LV Switchboard Level 2 ACB - 3200A MCCB 3200A Level 3 MCCB 1250A Fuses 630A Switchboard, Panelboard or MCC Level 4 MCBs - 100A

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015 Low Voltage EasyPact TVS Motor starters from 6A to 630A Catalog 2015 Designed for the essential EasyPact TVS General contents EasyPact TVS contactors, 6 A to 630 A A-1 EasyPact TVS thermal overload relays

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Circuit protection and control devices 0.5 to 6300 A

Circuit protection and control devices 0.5 to 6300 A Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V. Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650515200 Ed.1 of 21/02/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Short-circuit current limiter S800-SCL-SR

Short-circuit current limiter S800-SCL-SR Short-circuit current limiter S800-SCL-SR 2 ABB Short-circuit current limiter S800-SCL-SR Self-resetting current limiting module S800-SCL-SR is ABB s innovative self-resetting current limiting module which

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

An electrical panel capable of evolving

An electrical panel capable of evolving An electrical panel capable of evolving Prisma TT Low voltage factory built assemblies Buildings Commercial & Industrial Make the most of your energy General For a dependable electrical installation Total

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

TECHNICAL SPECIFICATIONS OF PCC PANEL

TECHNICAL SPECIFICATIONS OF PCC PANEL S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary Breakers and Switches Tmax XT Moulded-case circuit-breakers Simply extraordinary Tmax XT Simply extraordinary ABB is proud to present you the result of a long and intense research and development project:

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications 2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

COMPONENTS. Multi-functional Main AC Switch for rolling stock Type MACS

COMPONENTS. Multi-functional Main AC Switch for rolling stock Type MACS COMPONENTS Multi-functional Main AC Switch for rolling stock Type MACS GENERAL INFORMATION MACS is a platform for Main AC Switch installed on electric rail vehicles running on AC networks. The AC vacuum

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Low Voltage Main Distribution Board

Low Voltage Main Distribution Board s M series... Low Voltage Main Distribution Board Safe and intelligent power distribution Whether in industrial plants, in infrastructure or in buildings, all technical plant depends on the reliable supply

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650523200 Ed.1 of 23/07/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Compact Merlin Gerin 80 to 3200 A

Compact Merlin Gerin 80 to 3200 A LV power air circuit breakers and switch-disconnectors Catalogue Compact Merlin Gerin 80 to 3200 A 2005 Industries SA 5, rue Nadar 92506 Rueil-Malmaison Cedex France Tel : +33 (0)1 41 29 82 00 Fax : +33

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

JOSLYN CLARK VACUUM CONTACTORS

JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS SECTION JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS 339 TM CONTENTS Joslyn Clark - New 300Amp, 1140 Volt Heavy Duty Mining Vacuum

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A Quality For You. How simple and functional can a range of moulded-case circuit-breakers be? It was answering this question, which

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

World Super Series WSS The extensive breaker series from Mitsubishi Electric

World Super Series WSS The extensive breaker series from Mitsubishi Electric MODEL PUSH TO TRIP TEST 3 P IEC60947-2 JIS C 8201-2 Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN60947-2 40 C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information