KATKO Safety Switches:
|
|
- Madeline Bryant
- 5 years ago
- Views:
Transcription
1 KATKO Safety Switches: Reliability, Economy, Safety KATKO/ /AL 1
2 KUM 16-25A Dimensions: Overall: 130,4 x 96,4 x 42,0 Mounting holes: 118,0 x 84,0 -Polycarbonate or ABS IP65 enclosure -Excellent UV and chemical attack resistance. (Added additive with Special UV-stability) -Self-extinguishing material and excellent insulating properties (flame retarded UL94 V0) -available in grey/black or yellow/red -Provision for 3 padlocks -stainless steel cover fixing screws KATKO/ /AL 2
3 KUM 32-63A Dimensions: Overall: 190 x 144 x 131 Mounting holes: 178 x 132 -Polycarbonate or ABS IP65 enclosure -Excellent UV and chemical attack resistance. (Added additive with Special UV-stability) -Self-extinguishing material and excellent insulating properties (flame retarded UL94 V0) -available in grey/black or yellow/red -stainless steel cover fixing screws -Provision for 3 padlocks KATKO/ /AL 3
4 Easy To Install SAVE TIME AND MONEY ON INSTALLATION! 6 cable entries two M25 & M32 mm and one M20 as standard on the top and bottom. Knock-out glands are easy to open. Retained handle you do not have to unscrew to remove cover Door interlock with defeat mechanism Padlocking in OFF-position prevents access to the actuator Neutral & earth terminals fitted on 3 pole switch. (2,5-35 mm 2 ) Earth only on 4 pole switch Enclosure mounting screws isolated from the inside housing keeping the integrity of the IP65 rating. Large cable terminals 16-25A: 1,5-16 mm A: 2,5-35 mm2 Fully rated Load Break Switch Breaking capacity of 8xAC23 rating. Back up fuse rating to match motor manufacturers recommendation Reliable position indication KATKO/ /AL 4 Retrofit snap on auxilliary contacts No need to touch existing cabling Plug in switch enables installer to unplug for ease of cabling
5 Easy To Install Assembly dimensions 118,0 x 84,0 on the back Knock-out gland M20 Knock-out gland M25 Assembly dimensions 178x132 on the back KATKO/ /AL 5
6 KUM 3p and KUM 4p KATKO/ /AL 6
7 KUM 6-8P and KKVM 332 KATKO/ /AL 7
8 Multi-purpose enclosure U3 fits with the following KATKO switches KU 3P (16-63A) KU 4P (16-63A) KU 6P (16-63) KU 8P (16-63A) VKA KU 3P+KKV (Fuse Switch Disconnector) KATKO/ /AL 8
9 Dimension drawings: PC Enclosures KATKO/ /AL 9
10 Sheet steel enclosed A IP 65; Enclosure types TT005, TR01, TR02, TR03 IP 55; Enclosure types TR04, TR05 Good corrosion resistance Provision for 3 padlocks KATKO/ /AL 10
11 Dimension drawings: sheet steel (1/2) KATKO/ /AL 11
12 Dimension drawings: sheet steel (2/2) KATKO/ /AL 12
13 Aluminium enclosed A IP 66/65 Wide operating temperature range Excellent to hard weather conditions Good resistance against chemical attack Provision for 3 padlocks KATKO/ /AL 13
14 Dimension drawings: A2 and A3 A2 A3 KATKO/ /AL 14
15 Stainless steel enclosed A IP 66; Enclosure type H23, H32, H02 IP 65; Enclosure type H03, H04 According to AISI 316 (Acid proof) Where hygiene and good protection against corrosion is required Provision for 3 padlocks KATKO/ /AL 15
16 Dimension drawings: Stainless steel KATKO/ /AL 16
17 EMC Protected A Tested according to EN with EMCglands and shielded power cable Provision for 3 padlocks KATKO/ /AL 17
18 Switch fuses and safety switches in motor supply L1 L2 L3 KATKO s SWITCH FUSE KVKE Contactor Thermal relay Cable Aluminium copper 0 1 KATKO s SAFETY SWITCH/ ISOLATING SWITCH M 3~ KATKO/ /AL 18
19 KUM, KUT, KUA, KUR technical values KUM/KUT/KUA/KUR 16A 25A 32A 40A 63A 80A 125A 200A 250A 400A 630A 800A 1000A Rated insulation voltage Ui (V) Rated thermal current Ith (A) Rated thermal current Ithe (A) Rated operational current Rated operational power Ie(A) 400V AC V V V AC V V V AC V P (kw) 690V for 3-phase3-vaiheiselle (1500 r.p.m.) 400V 7, squirrel cage induction motors AC V , Rated fused short circuit current 690V Back-up fuse (A) ** R.M.S value Ik (ka) Peak value (ka) 7,2 7,2 7,2 8,7 8,7 13, Rated short circuit making capacity Icm (ka) 690V 2,5 2,5 2,5 3,3 3,3 5, Rated short time withstand current Icw (ka) 690V 1,7 1,7 1,7 2,3 2,3 3, Rated breaking capacity I cn (ka) 400V AC V V Electrical endurance (number of operations) Mechanical endurance (number of operations) Terminals / *Bolt size Cu (mm 2 ) 1,5-16 1,5-16 1,5-16 2,5-35 2, M10 M10 M10 M12 M12 M12 Max. terminal torque (Nm) 1,8 1,8 1,8 2,5 2,5 4,5 4, ** Rated short time withstand current (1s) 50kA KATKO/ /AL 19
20 KATKO Switches for DC use KATKO/ /AL 20
21 Selection Guide 400V Motor Apparatus board of the distripution cable Cable Safety Switch Cable from safety Power Contactor Thermal relay Swich Fuse Fuse Copper Aluminium switch to motor kw type Type Range type A MCMK AMCMK Type MCMK 0,18 LRD-05 0,63-1,0 2 am 0,25 1,0-1,7 2 am 0,37 LRD-06 1,0-1,7 2 am 3x1,5+1,5 3x1,5+1,5 0,55 1,0-1,7 2 am 0,75 LC1-D09 LRD-07 1,6-2,5 4 am 1,1 LRD-08 2,5-4,0 4 am KUM 325U 1,5 2,5-4,0 4 am 2,2 LRD-10 4,0-6,0 6 am 3x2,5+2,5 3x2,5+2,5 3,0 LRD-12 5,5-8,0 8 am 4,0 LRD am 3x6+6 3x6+6 5,5 LC1-D12 LRD am 7,5 LC1-D18 LRD KVKE am 11 LC1-D25 LRD am 3x x LC1- D32 LRD am KUM 363U 18,5 LC1-D40 LRD am 3x x LC1- D50 LRD am 30 LC1-D65 LRD KVKE am 3x x70+21 KUT 3125 VT1.V 3x LC1- D80 LRD am 45 LC1-D95 LRD am 3x x am 3x LC1-D150 LR9-D KVKE am 3x x KUT 3250 VT1.V 90 LC1-F am 3x LC1-F225 LR9-D KVKE am 3x (3x240+41) 132 LC1-F am 2(3x120+70) 2(3x185+57) KUT3400 VT1.V 3x LC1-F330 LR9-F am 2(3x240+72) 2(3x120+70) 200 LC1-F400 KVKE am 250 LC1-F500 LR9-F am 2(3x185+95) 2(3x300+88) KUT 3630 VT1.V 2(3x185+95) KATKO/ /AL 21
22 Selection Guide 500V Motor Apparatus board of the distripution cable Cable Safety Switch Cable from safety Power Contactor Thermal relay Swich Fuse Fuse Copper Aluminium switch to motor kw type Type Range type A MCMK AMCMK Type MCMK 0,37 2 am 3x1,5+1,5 3x1,5+1,5 0,55 2 am 0,75 LC1-D09 LRD-06 1,0-1,7 2 am 1,1 LRD-07 1,6-2,5 4 am KUM 325U 1,5 4 am 2,2 LRD-08 2,5-4,0 4 am 3x2,5+2,5 3x2,5+2,5 3,0 LRD-10 4,0-6,0 6 am 4,0 LRD-12 5,5-8,0 8 am 5,5 LRD am 3x6+6 3x6+6 7,5 LC1-D12 LRD KVKE am 9 LC1-D18 LRD am am 15 LC1- D25 LRD am 3x10+10 KUM 363U 3x ,5 LC1- D32 LRD am 22 LC1-D40 LRD am 30 LC1-D50 LRD am 3x x35+10 KUT 3125 VT1.V 3x LC1-D65 LRD KVKE am 45 LC1-D95 LRD am 3x x x LC1-D115 LR9-D am 75 KVKE am 3x x KUT 3250 VT1.V 3x LC1-D150 LR9-D am 110 LC1-F am 3x x x LC1-F225 LR9-D am 3x (3x120+41) 160 LC1-F265 KVKE am 2(3x185+57) KUT 3400 VT1.V 3x LC1-F330 LR9-D KVKE am 2(3x120+70) KUT 3630 VT1.V 250 LC1-F400 LR9-F am 2(3x185+95) 2(3x240+72) KUT 3800T 1.V 2(3x120+70) KATKO/ /AL 22
23 Selection Guide 690V Motor Apparatus board of the distripution cable Cable Safety Switch Cable from safety Power Contactor Thermal relay Swich Fuse Fuse Copper Aluminium switch to motor kw type Type Range type A MCMK AMCMK Type MCMK 0,18 0,4-0,63 2 gg 0,25 LRD-04 0,4-0,63 2 gg 0,37 0,63-1,0 2 gg 0,55 LRD-05 0,63-1,0 4 gg 3x1,5+1,5 3x1,5+1,5 0,75 1,0-1,7 4 gg 1,1 LRD-06 1,0-1,7 4 am KUM 325U 1,5 LC1-D09 LRD-07 1,6-2,5 KATKO 4 am 2,2 2,5-4,0 KVKE am 3,0 LRD-08 2,5-4,0 6 am 3x2,5+2,5 4,0 LRD-10 4,0-6,0 10 am 3x2,5+2,5 5,5 LRD-12 5,5-8,0 10 am 7,5 LC1-D12 LRD am 3x6+6 3x LC1-D25 LRD am 15 LRD am 18,5 LC1-D32 LRD am KUM 363U 22 LC1-D40 LRD am 3x x LC1-D50 LRD am 37 LC1-D am 3x x LC1-D80 LRD KVKE am KUT 3125 VT1.V 55 LR9-F am 3x x x LC1-F am 90 LR9-F am 3x x LC1-F KVKE am 3x KUT 3250VT1.V 132 LR9-F am 3x x LC1-F am 3x x LC1-F330 LR9-F KVKE am 2(3x120+41) KUT 3400 VT1.V 250 LC1-F am 2(3x120+70) 2(3x185+57) 3x LC1-F500 LR9-F am 3X LR9-F KVKE am 2(3x185+95) 2(3x240+72) KUT 3630 VT1.V 400 LC1-F am 2(3x185+95) 450 LR9-F am 2(3x300+88) 500 2(3x ) KUT 3800T 1.V 630 3(3x185+95) 4(3x185+57) 2(3x ) 800 KATKO/ /AL 3(3x ) 4(3x240+72) KUT 31000T 1.V 3(3x185+95) 23
24 Safety switches reference list KATKO/ /AL 24
25 (1) - (3) KATKO Safety Switches A (4) Aluminium Cable Connection (5) Four incoming cables (enough space) (7) In arctic use (8) In dusty places (9) Flat cable entries KATKO/ /AL 25
26 Certifications and Listings IEC CCA, CB certificates UL and cul listed products CE-marked products ISO 9001 ISO KATKO/ /AL 26
27 Making and braking capacities according to IEC Utilization Category Making Break Number of operating cycles I/Ie U/Ue Cos Ic/Ie Ur/Ue Cos AC-23 <100A 10 1,05 0,45 8 1,05 0,45 5 AC-23 >100A 10 1,05 0,35 8 1,05 0,35 3 I =Making current I C =Breaking current I E= Rated operational current U=Voltage before make U e =Rated operational voltage U r =Operational frequency or D.C. recovery voltage KATKO/ /AL 27
28 Operational performance according to IEC Rated operational current Ie 0 < Ie < Ie < Ie < Ie < Ie Number of operating cycles per hour AC and DC A categories Without current With current Number of operating cycles Total AC and DC B categories Without current With current Total KATKO/ /AL 28
29 Examples of KATKO FI certificates KATKO/ /AL 29
30 Examples of IEC and FI certificates KATKO/ /AL 30
31 Other KATKO products Load Break Switches A Fused Switches A Safety Switches A Isolating Switches Cam Switches 10-40A Motor Protection Switches Terminals Cable glands All Katko Switch Products fulfil the requirements for disconnectors and switchdisconnectors according to the IEC KATKO/ /AL 31
32 Any questions? KATKO/ /AL 32
33 Please visit our website for more information KATKO/ /AL 33
SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA
ENCLOSED SWITCHES SAFETY SWITCHES / ISOLATORS 16-800A TECHNICAL DATA Safety switches / isolators 10A 16A 25A 40A 63A 80A 125A 160A 200A 250A 315A 400A 630A 800A Rated Insulation voltage Ui (V) 690 690
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationPRODUCT CATALOGUE SAFETY SWITCHES, LOAD BREAK SWITCHES, SWITCH FUSES, DISCONNECTORS, ISOLATORS, TERMINALS
EASY TO INSTALL PRODUCT CATALOGUE SAFETY SWITCHES, LOAD BREAK SWITCHES, SWITCH FUSES, DISCONNECTORS, ISOLATORS, TERMINALS A FAMILY COMPANY FROM FINLAND PROVIDING SAFETY ON A GLOBAL SCALE The history of
More informationEASY TO INSTALL PRODUCT CATALOGUE SAFETY SWITCHES, LOAD BREAK SWITCHES, SWITCH FUSES, DISCONNECTORS, ISOLATORS, TERMINALS
EASY TO INSTALL PRODUCT CATALOGUE SAFETY SWITCHES, LOAD BREAK SWITCHES, SWITCH FUSES, DISCONNECTORS, ISOLATORS, TERMINALS A FAMILY COMPANY FROM FINLAND PROVIDING SAFETY ON A GLOBAL SCALE The history of
More informationEASY TO INSTALL PRODUCT CATALOGUE SAFETY SWITCHES, LOAD BREAK SWITCHES, SWITCH FUSES, DISCONNECTORS, ISOLATORS, TERMINALS
EASY TO INSTALL PRODUCT CATALOGUE SAFETY SWITCHES, LOAD BREAK SWITCHES, SWITCH FUSES, DISCONNECTORS, ISOLATORS, TERMINALS A FAMILY COMPANY FROM FINLAND PROVIDING SAFETY ON A GLOBAL SCALE The history of
More informationLOAD BREAK SWITCHES AND SWITCH FUSES
easy to install LOAD BREAK SWITCHES AND SWITCH FUSES Sixty years of innovation in developing and producing high-quality switches When Mr Kauko Hyryläinen founded KATKO in 1941, one of his key targets
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationLOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA
LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution
More informationSwitch Disconnectors
Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More information125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request
125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for
More informationGeneral Informations 2 Technical data 3 Basic designs 4-8
Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More information70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX
70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More information500V / V /
LOAD BREAK SWITCHES 125-630 A TECHNICAL DATA ATEX RoHS Compliant 2002/95/EC LOAD BREAK SWITCHES 16A 25A 40A 63A 80A 125A 160A KU / KU / KU / KU / KU / KU / VKA / VKA / KUE KUE KUE KUE KUE KUE EVA EVA VKA
More informationTHE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions
THE SANTON FCS-TYPE SWITCH DISCONNECT Superior Switch Solutions The technical information given in this table applies to and pole fuse combination switches. A B NOMINAL RATING 0A A FUSE COMBINATION SWITCHES
More informationEuroload Changeover Switch
Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.
More informationDC-Switch Disconnectors for Photovoltaic acc. to IEC
DC-Switch Disconnectors for Photovoltaic acc. to IEC 60364-7-712 Ratings DC-Switch Disconnectors Rated current DC21B at U e I th open 4 poles in series Type A A V LS16 16 16 LS25 25 25 LS32 32 32 LS40
More informationMini DC - Isolators for Photovoltaic
Mini DC - Isolators for Photovoltaic acc. to IEC 60364-7-712 Quality made in D1024E171 Technical catalogues and news under: www.benedict.at Contactors Motor-Starter Mini-Contactors Contactors Overload
More informationAn innovative technology
The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,
More informationEnclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes
Protection and Connection Enclosed DC rated switchdisconnectors OTDCP from 16 to 32 Amperes Enclosed OTDC switches from 16 to 32 Amperes meet the demanding requirements of photovoltaic applications. Enclosed
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationADVANCE GRP Series 125A Switched Interlocked socket outlets
DVNCE GRP Series 125 Switched Interlocked socket outlets DVNCE GRP Series 125 > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STNDRDS EN 60309-1 Plugs, socket outlets and couples for industrial purposes.
More informationLOAD BREAK SWITCHES A TECHNICAL DATA FOR KU, KUE, VKA AND EVA SERIES
LOAD BREAK SWITCHES 16-250 A TECHNICAL DATA FOR KU, KUE, VKA AND EVA SERIES Load Break Switches Rated insulation voltage, U i (V) Rated thermal current, I th (A) Nominal values with cable size (mm 2 )
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More informationTechnical Information
C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationA Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.
C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,
More informationMSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3
Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationApprovals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking
MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationApprovals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking
MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationMotorized switch-disconnectors OTM 40 to 125 Amperes
Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationLV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity
LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact
More informationLR-LX-LK-LW Safety Switches with separate actuator
LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationAC Switches: ML & MN Series DC Switches: MDC1A Series
AC Switches: ML & MN Series DC Switches: MDC1A Series Australian & New Zealand Distributor Leveltec Engineering Pty Ltd Gloucester P:+612 6558 9264 F:+612 6558 1002 Sydney P:+612 9299 5630 F:+612 6558
More informationK30H001YP cam star-delta switch - 3-pole A - screw mounting
Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationLow Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201
Low Voltage Products Enclosed switches Brochure OT_KSE 1 GB 05_02 O I N O SafeLine OF F 2 I Enclosed switches Contents: General... 4 Technical data... 5 Switches in plastic enclosure General... 6 Ordering
More informationSolar Installer Range. Bright solutions
Solar Installer Range Bright solutions IMO is at the forefront of control component technology specifically developed for the renewable energy market and in particular solar energy. Whether meeting the
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationDCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC
More informationSIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.
Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity
More informationSection Contents. Disconnect Switches
Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationSafety switches for hinged doors
4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit
More informationCylindrical fuse-link
Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH
More informationChangeover & Bypass Sw it ches
Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationSIRCO M and MV Universal load break switches from 16 to 160 A
SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV
More informationModel Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1
Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationJust the right switch for your application
Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality
More informationGeneral information about motor protection
Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More informationSafety switches for hinges
Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded
More informationMANUALLY OPERATED CHANGEOVER SWITCHES
are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationPowerLine OS Switch Fuses A, 690V
Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected
More informationSwitches disconnectors with fuse-holders. XNF series TF series
Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationApprobationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking
Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description
More informationOverview of Low voltage equipment - Moulded-case & Air circuit-breakers
Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are
More informationDATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT
44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7
More informationThe complete offer Enclosed switch-disconnectors / Isolators
June 2009 The complete offer Enclosed switch-disconnectors / Isolators May 29, 2009 Slide 1 Contents Why use enclosed switch-disconnectors Applications and application demands The ABB products and features
More informationGeneral_technical_data Series
Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow
More informationIP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.
General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors
More informationNon-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.
disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationEnclosed Switches and Safety Switches
Enclosed Switches and Safety Switches Enclosed Switches and Safety Switches Contents General information... 2 Description... 5 Ratings... 8 Plastic enclosed switches and safety switches...11 Metal enclosed
More informationENYSTAR Load Centers up to 250 A
PASSION FOR POWER. up to 250 A according to IEC 61439-3 for commercial and industrial buildings Download at www.hensel-electric.en made in GERMANY since 1931 up to 250 A according to IEC 61439-3 for commercial
More informationSafety switches for hinged doors
4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More informationCircuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63
Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10
More informationATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions
to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationPendant control stations 6
Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment
More informationCam switches. CA Series
Cam switches CA Series CA Series Overview The range of cam switches CA series includes ratings from to 6A and insulation voltages of 69. The CA series offers IP terminals protection degree (it s possible
More information