The complete offer Enclosed switch-disconnectors / Isolators

Size: px
Start display at page:

Download "The complete offer Enclosed switch-disconnectors / Isolators"

Transcription

1 June 2009 The complete offer Enclosed switch-disconnectors / Isolators May 29, 2009 Slide 1

2 Contents Why use enclosed switch-disconnectors Applications and application demands The ABB products and features Technical documentation Conclusion Link to flash-plugin May 29, 2009 Slide 2

3 Why use enclosed switch-disconnectors Local isolation Main switch Control switch Fireman switch Etc. May 29, 2009 Slide 3

4 Why use enclosed switch-disconnectors Personal safety Maintenance isolation Electrical isolation Safety standards Machine Directive EN60204 Definitions Machine Directive EN60204 May 29, 2009 Slide 4

5 Where to find the applications Air conditioners / chillers Elevators Ventilation fans Lighting Corn drier Conveyor belts Car washing machines Washing machines Restaurant kitchens Electrical distribution systems May 29, 2009 Slide 7

6 Example of industrial application May 29, 2009 Slide 8

7 Example of industrial application May 29, 2009 Slide 9

8 Example of industrial application May 29, 2009 Slide 10

9 Example of industrial application May 29, 2009 Slide 11

10 Example of solar application May 29, 2009 Slide 12

11 Example of application May 29, 2009 Slide 13

12 Example of application Local isolation May 29, 2009 Slide 14

13 Example of application Main switch May 29, 2009 Slide 15

14 Example of application Control switch May 29, 2009 Slide 16

15 Example of application Fireman switch Fireman switch May 29, 2009 Slide 17

16 Ratings to utilization categories Enclosed switch-disconnectors AC-21A AC-22A AC-23A Utilization categories AC Utilization categories DC May 29, 2009 Slide 18

17 The complete range Switch disconnectors / Isolators EN , Ue 400 V Ie AC-21, 22A May 29, 2009 Slide 21 Ie AC-23A Plastic BW,P BW,P P P P P Aluminum KSE KSE KSE KSE KSE KSE KSE KSE KSE KSE Steel sheet L, L, L, L, L, L, Stainless sheet R R R R R R

18 Wide range of functions 2, 3, 4 and 6 pole Auxiliary blocks Early brake and late make auxiliary contact for electrical interlocking All enclosed switches can be fitted with additional contact blocks. May 29, 2009 Slide 22

19 Early brake, late make May 29, 2009 Slide 23

20 Enclosed change-over switch May 29, 2009 Slide 24

21 For safety and reliability Front operated High quality enclosure material Plastic Steel Aluminum Stainless steel AISI 304 Acid proof steel AISI 316 AC-22A = <1600A AC-23A = <1250A May 29, 2009 Slide 25

22 For safety and reliability Side operated Handle, axis & insert is one system, factory assembled by ABB Knockouts for padlock in I position AC-22A = < 40A AC-23A = < 25A High quality enclosure material Aluminum Plastic/PBT Properties of plastic material May 29, 2009 Slide 26

23 For safety and reliability Padlockable in the Off position as standard Shackle for up to 6 padlocks May 29, 2009 Slide 28

24 For safety and reliability To prevent personal injury in case of short circuit when operating the switch On all aluminum enclosures with Ie > 160 A On all steel sheet enclosures with Ie > 125 A May 29, 2009 Slide 29

25 For the user Easy installation Clear marking of ratings Threaded cable entries Knockouts on plastic enclosures Drilling plan on the backside Clear molded position indication (I-O) May 29, 2009 Slide 30

26 Approvals and certificates Standards EN UL ATEX EMC Environment declaration CE declaration of conformity May 29, 2009 Slide 32

27 Technical documentation Available on Internet and in ABB Library Dimension drawings and drilling plans Selection tool Circuit diagrams Operating instructions Approvals/certificates Printed materials/sales documentation For more information please visit : May 29, 2009 Slide 33

28 ABB Your local partner globally Complete range of products Availability all around the world Local sales companies in over 130 countries May 29, 2009 Slide 34

29 Conclusion A safe solution For a wide range of applications Designed for safe and easy use Corresponding to international standards May 29, 2009 Slide 35

30

Enclosed switches and safety switches Main Catalogue. 2CMC341002D0002 January 2009

Enclosed switches and safety switches Main Catalogue. 2CMC341002D0002 January 2009 Enclosed switches and safety switches Main Catalogue January 2009 Enclosed switches and safety switches Contents General description/technical data... 4 Ratings... 8 Switch-disconnectors / isolators Plastic

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Enclosed Switches and Safety Switches

Enclosed Switches and Safety Switches Enclosed Switches and Safety Switches Enclosed Switches and Safety Switches Contents General information... 2 Description... 5 Ratings... 8 Plastic enclosed switches and safety switches...11 Metal enclosed

More information

AC Switches: ML & MN Series DC Switches: MDC1A Series

AC Switches: ML & MN Series DC Switches: MDC1A Series AC Switches: ML & MN Series DC Switches: MDC1A Series Australian & New Zealand Distributor Leveltec Engineering Pty Ltd Gloucester P:+612 6558 9264 F:+612 6558 1002 Sydney P:+612 9299 5630 F:+612 6558

More information

I Ex-Safety switches I

I Ex-Safety switches I 3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX

More information

Brocure panorama. Switches for photovoltaic applications Disconnect switches OTDC and OTDCP

Brocure panorama. Switches for photovoltaic applications Disconnect switches OTDC and OTDCP Brocure panorama Switches for photovoltaic applications Disconnect switches OTDC and OTDCP DC switch-disconnectors, front operated 16...800 A, IEC IEC 60947 OTDC16F2 OTDC16F3 OTDC16F4 OTDC100E02 OTDC100E11

More information

KATKO Safety Switches:

KATKO Safety Switches: KATKO Safety Switches: Reliability, Economy, Safety KATKO/2007.01/AL 1 KUM 16-25A Dimensions: Overall: 130,4 x 96,4 x 42,0 Mounting holes: 118,0 x 84,0 -Polycarbonate or ABS IP65 enclosure -Excellent UV

More information

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety ATX PRE Series 125 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator

More information

Low Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201

Low Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201 Low Voltage Products Enclosed switches Brochure OT_KSE 1 GB 05_02 O I N O SafeLine OF F 2 I Enclosed switches Contents: General... 4 Technical data... 5 Switches in plastic enclosure General... 6 Ordering

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution

More information

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety ATX PRE Series 63 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Rotating Power AC Motors and Generators

Rotating Power AC Motors and Generators Rotating Power AC Motors and Generators Preferred Partner Building on over one hundred years design experience and application understanding, ABB is the world s leading manufacturer of low and high voltage

More information

PRE Series 125 Amp Plugs and Sockets Increased Safety

PRE Series 125 Amp Plugs and Sockets Increased Safety s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 125 Amp s and Sockets - IK10 Applications s and sockets are used with stationary or portable electrically operated devices

More information

Low Voltage Products. Breakers and Switches for the HVAC segment

Low Voltage Products. Breakers and Switches for the HVAC segment ow Voltage Products Breakers and witches for the VAC segment ABB s extensive range of products for the VAC segment ABB s very extensive range of appliances and systems for low voltage power distribution

More information

Switch Disconnectors

Switch Disconnectors Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles

More information

SWITCH DISCONNECTORS PLANET -SWITCH.

SWITCH DISCONNECTORS PLANET -SWITCH. SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE

More information

ATX DPD Series Distribution Panelboards Flameproof

ATX DPD Series Distribution Panelboards Flameproof ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA ENCLOSED SWITCHES SAFETY SWITCHES / ISOLATORS 16-800A TECHNICAL DATA Safety switches / isolators 10A 16A 25A 40A 63A 80A 125A 160A 200A 250A 315A 400A 630A 800A Rated Insulation voltage Ui (V) 690 690

More information

WLP Disconnect Switches for Solar and other Applications

WLP Disconnect Switches for Solar and other Applications Automation & Power World: April 18-21, 2011 WLP-121-1 Disconnect Switches for Solar and other Applications Inc. April 19, 2011 Slide 1 WLP-121-1 Disconnect Switches for Solar and other Applications Speaker

More information

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes Protection and Connection Enclosed DC rated switchdisconnectors OTDCP from 16 to 32 Amperes Enclosed OTDC switches from 16 to 32 Amperes meet the demanding requirements of photovoltaic applications. Enclosed

More information

I Ex-safety switches I

I Ex-safety switches I 3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99

More information

PRE Series 63 Amp Plugs and Sockets Increased Safety

PRE Series 63 Amp Plugs and Sockets Increased Safety Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator sets Air conditionings Compressors

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety PRE Series: 16 A Plugs and Sockets Increased Safety ELV: Extra Low Voltage Plug Wall Mounting Socket Mobile Socket Flush Socket 20/25 Vac 20/50 Vdc 40/50 Vac LV: Low Voltage Plug Wall Mounting Sockets

More information

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A. SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A. New SACE Tmax XT. Simply XTraordinary. ABB SACE is proud to present you the result of a long and intense research and development

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They

More information

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

Switch-disconnectors OTDC and OTDCP

Switch-disconnectors OTDC and OTDCP PROTECTION AND CONNECTION Switch-disconnectors OTDC and OTDCP Switches for photovoltaic and ESS applications Designed for harsh environments Compact and modular design Reduced power losses Switch-disconnectors

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

DisconnectSwitches16Ato250A Enclosed,DoorMountandPanelMountDisconnects 3,4,and6PoleModels 3PadlockableHandle Styles Add-onPowerContacts Auxiliary

DisconnectSwitches16Ato250A Enclosed,DoorMountandPanelMountDisconnects 3,4,and6PoleModels 3PadlockableHandle Styles Add-onPowerContacts Auxiliary DisconnectSwitches16Ato250A Enclosed,DoorMountandPanelMountDisconnects 3,4,and6PoleModels 3PadlockableHandle Styles Add-onPowerContacts Auxiliary Contacts ShaftExtensions SpareHandles Door Mount Disconnect

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING TUNNEL54 Safety and fire resistance VENTILATION LIGHTING 238 TUNNEL54 Safety and fire resistance VENTILATION TUNNEL54 fire resistant sockets for ventilators Page 240 LIGHTING TUNNEL54 junction boxes with

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

Safety Switches Series 8537

Safety Switches Series 8537 Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part

More information

PowerLine OS Switch Fuses A, 690V

PowerLine OS Switch Fuses A, 690V Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected

More information

NPA-CP. Pendant control station OPTIONS FEATURES CERTIFICATIONS

NPA-CP. Pendant control station OPTIONS FEATURES CERTIFICATIONS Pendant control station NPA-CP Pendant station for direct control of industrial machines. Sturdy and handy, NPA-CP is speciically designed for heavy duty in industrial environments. FEATURES The cable

More information

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific) 4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are

More information

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear MEDIUM VOLTAGE PRODUCTS Powerbloc Pre-assembled modules for building medium voltage switchgear Powerbloc are the ideal solution for replacing fixed circuit breakers with withdrawable circuit breakers,

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0) Features: FONTECK INDUSTRIES BFBD BIFURCATED FAN (ATEX Certified, Gas Group IIB+H2) ATEX Certified Comply with standards: EN 14986, EN 13463 1 Driven directly by ATEX certified motor 15 sizes with case

More information

Enclosed switch & safety enclosure. for local and safety breaking applications

Enclosed switch & safety enclosure. for local and safety breaking applications Enclosed switch & safety enclosure for local and safety breaking applications Secure your installation Local breaking enclosures are installed near to a motor or a machine in order to separate them from

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED-CASE AND CIRCUIT BREAKER ENCLOSURES

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers Move to modern enclosed disconnect switch technology Enclosed disconnect switches eot Manual motor controllers The next generation of enclosed disconnect switches... Cutting edge design and technology

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Compact Load Break Switches 16A to 125A

Compact Load Break Switches 16A to 125A Compact Load Break Switches 16A to 125A Safe solutions for your industry Foreword Qualified Eng. Heinz Schmersal and Ind. Qualified Eng. Philip Schmersal Partner-managers of K.A. Schmersal GmbH & Co. KG

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty

More information

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description. General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors

More information

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations Version:- 3.0 Date of Issue:- Dec 2013 Page 1 of 13 NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations 1. Purpose This document is the technical specification

More information

Arc flash hazard mitigation

Arc flash hazard mitigation Low Voltage Products Arc flash hazard mitigation Each year more than 2,000 people are treated in burn centers with severe arc flash injuries. ABB designs and manufactures products and solutions to provide

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

TeSys Enclosed Starters. Let TeSys watch over your machinery

TeSys Enclosed Starters. Let TeSys watch over your machinery TeSys Enclosed Starters Let TeSys watch over your machinery Standard offer applications: Fans, blowers, ventilators Pumps: water pumps, heat pumps, etc. Compressors Elevators Automatic gates, roof window

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring: SERIES D DISCONNECT SWITCHES 1 Amp 0 Amp 00 & 0 Volt Load Make/Load Break Positive Opening Compact Size Modular Construction Horse Power Rated Custom Versions Featuring: Auto Alignment Shaft Wide Handle

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block. PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants

More information

NPA-CP Pendant Control Station

NPA-CP Pendant Control Station NPA-CP Pendant Control Station Pendant station for direct control of industrial machines. Sturdy and handy, NPA-CP is specifically designed for heavy duty in industrial environments. FEATURES The cable

More information

Operating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1

Operating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1 7F Series - Filter Fan (24 500) m³/h (14.1...294.3) CFM 7F Features 7F.50.8.xxx.1020 7F.50.8.xxx.2055 7F.50.8.xxx.3100 Filter Fan for electrical cabinets and enclosures 120 V or 230 V AC versions Very

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 Ø48. Panel Door

Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 Ø48. Panel Door Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 O I II Ø4 Panel Door on to the best GEERAL Contents General IDEX Page o. Technical Data 1 ing Programmes 2 Front 3 Rear 5 Plastic Enclosure Metal Enclosure Accessories

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0) Features: FONTECK INDUSTRIES AFBD AXIAL FAN (ATEX Certified, Gas Group IIB+H2) ATEX certified Comply with standard: EN 14986, EN13463 1 Driven directly by ATEX certified motor 15 sizes with case opening

More information

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

E 90 range of fuse disconnectors and fuseholders Uncompromising performance E 90 range of fuse disconnectors and fuseholders Uncompromising performance Designing simplicity ABB competence serving the most demanding customers Suitability for disconnection and switching, effective

More information

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com

More information

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Main current switches >180 A are realized in metal enclosures. Internationally approved. E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility

More information

TeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications

TeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications TeSys Enclosed Starters Let TeSys ensure safety in your simple motor applications TeSys Innovative and intuitive solutions to protect, monitor and control The TeSys range is suitable for motor and power

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 6A 200A 30A 200A Fusible Disconnect SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings

More information

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects Low Voltage Switches Enclosed switches - eot Manual motor controllers and disconnects The next generation of enclosed switches General information The eot series of enclosed manual motor controllers are

More information

LOAD BREAK SWITCHES AND SWITCH FUSES

LOAD BREAK SWITCHES AND SWITCH FUSES easy to install LOAD BREAK SWITCHES AND SWITCH FUSES Sixty years of innovation in developing and producing high-quality switches When Mr Kauko Hyryläinen founded KATKO in 1941, one of his key targets

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES DESIGN FEATURES Double break contacts Polycarbonate shroud for wired terminal protection included Excellent switching & high short circuit capacity Compact and reliable Easy installation Front, rear and

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products 94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation

More information

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit

More information

Rossi S.p.A a company of the Habasit Group -Copyright: all right reserved- Author: R&D - Electric Motors Division 1

Rossi S.p.A a company of the Habasit Group -Copyright: all right reserved- Author: R&D - Electric Motors Division 1 www.wmmotors.com Rossi S.p.A. 2011 a company of the Habasit Group -Copyright: all right reserved- Author: R&D - Electric Motors Division 1 The Company WM Motors srl was born in mid-2013 on a covered area

More information

Catalog. Industrial Plugs & Sockets

Catalog. Industrial Plugs & Sockets Catalog Industrial Plugs & Sockets Contents Page Introduction... 4 IEC 60309-2 (clock)... 5 Product overview Critical & Safe... 6 Tough & Safe... 7 Easy & Safe... 8 Plugs... 10 Connectors... 13 Switched

More information

Unicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Unicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum Unicode 2 Series Pre-Drilled Control Stations Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum, Type 4X ; Type 4X Applications Local control stations and motor control stations

More information

BARON-MAX V Range Vertical Machining Centers Powerful Machines, Simple User Friendly Programming At a Very Affordable Pricing

BARON-MAX V Range Vertical Machining Centers Powerful Machines, Simple User Friendly Programming At a Very Affordable Pricing BARON-MAX V Range Vertical Machining Centers Powerful Machines, Simple User Friendly Programming At a Very Affordable Pricing Cost Effective, High Performance Vertical Machining Centers BARON-MAX V Range

More information