1 Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We offer complete line of Cam Switches with as many as 24 switch contacts. Each contact has two fixed terminals and a moving contact bridge. All switches are designed with four switching angles, finger proof construction, captive screws and cable end stops, along with quality construction and excellent engineered design that surpasses the industry standards. UL, CSA, and VDE 0660 part 107 approvals as well as meeting IEC 947-3, EN and CE all verify the excellence of the product. All MERZ products meet ROHS certification as well. JCAM SWITCHES Model Ratings / Product Numbering System...J2 Technical Data...J3 CAM SWITCH TYPES: On-Off Switches...J4, J5 Change-Over Switches (Transfer Switches)...J6 - J10 Reversing Switches (Drum Switches)...J11 Multi-Speed Switches...J12, J13 Wye-Delta Switches...J14 Step Switches (Tap Switches) with 0 Position...J15-J21 Step Switches (Tap Switches) with-out 0 Position...J22-J28 Group Switches...J29-J31 Code Switches...J32, J33 Voltmeter Switches...J34, J35 Ammeter Switches...J36-J37 Single-Phase Starter Switches...J38 Handle and Mounting Code...J39 Handle and Mounting Dimensions...J40 Cam Switch Enclosures...J41 Cam Switch Accessories...J42 Custom Cam Switch Order Form...J43 Index J

2 MODEL AN PRODUCT INFORMATION Cam Switch Model Ratings Switch Model General Purpose 3-phase Motor 3-phase Motor 1-phase 240V 480V 600V 120V 240V A V hp hp hp hp hp Product Numbering System J 2 W / 3 - A B - Special Options Mounting Code (pg. J39) 3 Types: - 4-Hole Front Mount - Base Mount - Central Mount (22.5 or 30.5mm) Black lever handle standard on all cam switches. Consult factory for custom handle style Arrangement Factory Assigned: Up to 4 digits Switch Model 105 (16 amp) 451 (40 amp) 151 (20 amp) 656 (80 amp) 251 (25 amp) 756 (100 amp) Type A = On-Off Switches Z = By-Pass or Transfer Switches V = Step Switches V = Voltmeter or Ammeter Switches W = Reversing Switches or Drum Switches P = Multi-Speed Switches S = Wye-Delta Switches E = Single Phase Starter Switches Example: Reversing Switch; 25amp, 3-pole maintained, 4-hole, front mount handle = Part# W251/3-AB J2 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

3 TECHNICAL DATA Technical Data acc. to IEC 947-3, EN (DIN VDE 0660 part 107), UL and CSA Series Type * 756* Rated Uninterrupted current (by max. cross section) l u open - 1 th A * 125* lthe encapsulated A * 125* Rated insulation voltage U i (III/3) V Rated impulse with stand. voltage U imp (III/3) kv Rated operational current I e AC-21 A A * 125* Rated operational voltage U e A Making / Breaking capacity Utilization category AC-3 Motor switches for operational switching Single phase motor 3 x 230V kw 3 5,5 7, x 400V kw 5,5 7, , x 690V kw 5, x 230V kw 2, , x 400V kw 3 4 5,5 7, ,5 Utilization category AC-23 A Motor switches (Main Switches Maintenance Switches) Rated breaking capacity AC-23 A 3 x 230V kw 4 7, x 400V kw 7, x 690V kw 7, , x 230V A x 400V A x 690V A Utilization category AC-15 Control Switches 230V A Rated operational current L e 400V A Short-circuit capacity Max. fuse rating (gl-char.) A Rated conditional short-circuit current ka eff Rated short-circuit making capacity l cm ka ,4 3,4 Rated short-time withstand l cw (1-s-current) Aeff Isolating characteristics up to V Mechanical life -- Operating cycles Terminal screws (Pozidrive) M3 M3,5 M4 M5 M8 2 x M4 Screwdriver: Pozidrive Size Torque terminal scres Nm 0,8 1,0 1,8 2,2 3,5 3,5 Cable cross section min. mm² 1,0 1,0 1,0 1,5 1,5 1,5 Solid or multi-stranded min. mm² 4,0 4,0 6,0 10,0 25,0 35,0 Flexible with ferrule min. mm² 1,0 1,0 1,0 1,5 1,5 1,5 (DIN 46228) max. mm² 2,5 2,5 4,0 6,0 16,0 35,0 J 3 *656 = 100 A, 756 = 160 A with usage of extension terminals. (non-ul rating) UL Ratings: General Purpose 3-Phase Motor 3-Phase Motor 1-Phase (2 pole) A V V hp 3 5 7, V hp V hp V hp 0,5 1,0 1,5 2,0 7,5 10,0 240V hp 1,5 3,0 3,0 5,0 15,0 20,0 Cable cross section AWG-No Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J3

4 TYPE: ON-OFF SWITCHES ON-OFF SWITCHES Front Plate / Diagram 16 A105/1 - XX $ A151/1 - XX $ A251/1 - XX $ A451/1 - XX $ A656/1 - XX $ A756/1 - XX $ A105/2 - XX $ A151/2 - XX $ A251/2 - XX $ A451/2 - XX $ A656/2 - XX $ A756/2 - XX $ J 4 3 Pole 16 A105/3 - XX $ A151/3 - XX $ A251/3 - XX $ A451/3 - XX $ A656/3 - XX $ A756/3 - XX $ Pole 16 A105/4 - XX $ A151/4 - XX $ A251/4 - XX $ A451/4 - XX $ A656/4 - XX $ A756/4 - XX $ A105/62 - XX $ A151/62 - XX $ A251/62 - XX $ A451/62 - XX $ A656/62 - XX $ A756/62 - XX $ J4 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

5 TYPE: ON-OFF SWITCHES ON-OFF SWITCHES Front Plate / Diagram 16 A105/50 - XX $ A151/50 - XX $ A251/50 - XX $ A451/50 - XX $ A656/50 - XX $ A756/50 - XX $ Pole 16 A105/6 - XX $ A151/6 - XX $ A251/6 - XX $ A451/6 - XX $ A656/6 - XX $ A756/6 - XX $ Pole 1-contact priority 16 A105/22 - XX $ A151/22 - XX $ A251/22 - XX $ A451/22 - XX $ A656/22 - XX $ A756/22 - XX $ J 5 5 Pole 16 A105/96 - XX $ A151/96 - XX $ A251/96 - XX $ A451/96 - XX $ A656/96 - XX $ A756/96 - XX $ Pole 16 A105/10 - XX $ A151/10 - XX $ A251/10 - XX $ A451/10 - XX $ A656/10 - XX $ A756/10 - XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J5

6 TYPE: CHANGE-OVER SWITCHES WITH O-POSITION CHANGE-OVER SWITCHES WITH O-POSITION Front Plate / Diagram Maintained 16 Z105/1 - XX $ Z151/1 - XX $ Z251/1 - XX $ Z451/1 - XX $ Z656/1 - XX $ Z756/1 - XX $ J 6 Maintained 16 Z105/2 - XX $ Z151/2 - XX $ Z251/2 - XX $ Z451/2 - XX $ Z656/2 - XX $ Z756/2 - XX $ Pole Maintained 16 Z105/3 - XX $ Z151/3 - XX $ Z251/3 - XX $ Z451/3 - XX $ Z656/3 - XX $ Z756/3 - XX $ Pole Maintained 16 Z105/12 - XX $ Z151/12 - XX $ Z251/12 - XX $ Z451/12 - XX $ Z656/12 - XX $ Z756/12 - XX $ J6 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

7 TYPE: CHANGE-OVER SWITCHES WITH O-POSITION CHANGE-OVER SWITCHES WITH O-POSITION Font Plate / Diagram 5 Pole Maintained 16 Z105/9 - XX $ Z151/9 - XX $ Z251/9 - XX $ Z451/9 - XX $ Z656/9 - XX $ Z756/9 - XX $ Pole Maintained 16 Z105/26 - XX $ Z151/26 - XX $ Z251/26 - XX $ Z451/26 - XX $ Z656/26 - XX $ Z756/26 - XX $ J 7 7 Pole Maintained 16 Z105/234 - XX $ Z151/234 - XX $ Z251/234 - XX $ Z451/234 - XX $ Z656/234 - XX $ Z756/234 - XX $ Pole Maintained 16 Z105/24 - XX $ Z151/24 - XX $ Z251/24 - XX $ Z451/24 - XX $ Z656/24 - XX $ Z756/24 - XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J7

8 TYPE: CHANGE-OVER SWITCHES WITH NO O-POSITION CHANGE-OVER SWITCHES WITH NO O-POSITION Front Plate / Diagram Maintained 16 Z105/4 - XX $ Z151/4 - XX $ Z251/4 - XX $ Z451/4 - XX $ Z656/4 - XX $ Z756/4 - XX $ J 8 Maintained 16 Z105/5 - XX $ Z151/5 - XX $ Z251/5 - XX $ Z451/5 - XX $ Z656/5 - XX $ Z756/5 - XX $ Pole Maintained 16 Z105/6 - XX $ Z151/6 - XX $ Z251/6 - XX $ Z451/6 - XX $ Z656/6 - XX $ Z756/6 - XX $ Pole Maintained 16 Z105/23 - XX $ Z151/23 - XX $ Z251/23 - XX $ Z451/23 - XX $ Z656/23 - XX $ Z756/23 - XX $ J8 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

9 TYPE: CHANGE-OVER SWITCHES WITH NO O-POSITION CHANGE-OVER SWITCHES WITH NO O-POSITION Front Plate / Diagram 5 Pole Maintained 16 Z105/30 - XX $ Z151/30 - XX $ Z251/30 - XX $ Z451/30 - XX $ Z656/30 - XX $ Z756/30 - XX $ Pole Maintained 16 Z105/46 - XX $ Z151/46 - XX $ Z251/46 - XX $ Z451/46 - XX $ Z656/46 - XX $ Z756/46 - XX $ J 9 7 Pole Maintained 16 Z105/27 - XX $ Z151/27 - XX $ Z251/27 - XX $ Z451/27 - XX $ Z656/27 - XX $ Z756/27 - XX $ Pole Maintained 16 Z105/15 - XX $ Z151/15 - XX $ Z251/15 - XX $ Z451/15 - XX $ Z656/15 - XX $ Z756/15 - XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J9

10 TYPE: CHANGE-OVER SWITCHES WITH NO O-POSITION CHANGE-OVER SWITCHES WITH NO O-POSITION Front Plate / Diagram Spring Return 16 Z105/209 - XX $ Z151/209 - XX $ Z251/209 - XX $ Z451/209 - XX $ Z656/209 - XX $ Z756/209 - XX $ J 10 Spring Return 16 Z105/210 - XX $ Z151/210 - XX $ Z251/210 - XX $ Z451/210 - XX $ Z656/210 - XX $ Z756/210 - XX $ Pole Spring Return 16 Z105/211 - XX $ Z151/211 - XX $ Z251/211 - XX $ Z451/211 - XX $ Z656/211 - XX $ Z756/211 - XX $ J10 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

11 TYPE: REVERSING SWITCHES REVERSING SWITCHES Front Plate / Diagram Maintained 16 W105/2 - XX $ W151/2 - XX $ W251/2 - XX $ W451/2 - XX $ W656/2 - XX $ W756/2 - XX $ Pole Maintained 16 W105/3 - XX $ W151/3 - XX $ W251/3 - XX $ W451/3 - XX $ W656/3 - XX $ W756/3 - XX $ Pole with spring return from W105/5 - XX $ W151/5 - XX $ W251/5 - XX $ W451/5 - XX $ W656/5- XX $ W756/5 - XX $ J 11 3 Pole with spring return both sides 16 W105/7 - XX $ W151/7 - XX $ W251/7 - XX $ W451/7 - XX $ W656/7 - XX $ W756/7 - XX $ Pole without 0-Position Maintained 16 W105/12 - XX $ W151/12 - XX $ W251/12 - XX $ W451/12 - XX $ W656/12 - XX $ W756/12 - XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J11

12 TYPE: MULTI-SPEED SWITCHES Model Number Front Plate / Diagram 2- Speed Switches Tapped Windings 16 P105/1 - XX $ P151/1 - XX $ P251/1 - XX $ P451/1 - XX $ P656/1 - XX $ P756/1 - XX $ Speed Switches Tapped Windings with 1 16 P105/2 - XX $ P151/2 - XX $ P251/2 - XX $ P451/2 - XX $ P656/2 - XX $ P756/2 - XX $ J 12 2-Speed Switches Tapped Windings 0 Middle 16 P105/5 - XX $ P151/5 - XX $ P251/5 - XX $ P451/5 - XX $ P656/5- XX $ P756/5 - XX $ Speed Switches 2 Separate Windings 16 P105/7 - XX $ P151/7 - XX $ P251/7 - XX $ P451/7 - XX $ P656/7 - XX $ P756/7 - XX $ Speed Switches With Starting Position 16 P105/6- XX $ P151/6 - XX $ P251/6 - XX $ P451/6 - XX $ P656/6 - XX $ P756/6 - XX $ Speed Switches 2 Separate Windings 16 P105/48 - XX $ P151/48 - XX $ P251/48 - XX $ P451/48 - XX $ P656/48 - XX $ P756/48 - XX $ J12 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

13 TYPE: MULTI-SPEED SWITCHES MULTI-SPEED SWITCHES Model Number Front Plate / Diagram 2- Speed Switches Tapped Wingings Without 0 Position 2-Speed Switches Tapped Windings 2 Reversing 16 P105/127 - XX $ P151/127 - XX $ P251/127 - XX $ P451/127 - XX $ P656/127 - XX $ P756/127 - XX $ P105/3 - XX $ P151/3 - XX $ P251/3 - XX $ P451/3 - XX $ P656/3 - XX $ P756/3 - XX $ Speed Tapped Windings 1 and 2 16 P105/9 - XX $ P151/9 - XX $ P251/9 - XX $ P451/9 - XX $ P656/9- XX $ P756/9 - XX $ J 13 3-Speed Switches Tapped Windings 1 and 3 16 P105/10- XX $ P151/10 - XX $ P251/10 - XX $ P451/10 - XX $ P656/10 - XX $ P756/10 - XX $ Speed Switches Tapped Windings 2 and 3 16 P105/11 - XX $ P151/11 - XX $ P251/11 - XX $ P451/11 - XX $ P656/11 - XX $ P756/11 - XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J13

14 TYPE: WYE-DELTA SWITCHES Model Number Front Plate / Diagram J 14 Standard With 1 without Main s With 1 For Individually Compensated Motors 2 Reversing 2 Reversing With 16 S105/1 - XX $ S151/1 - XX $ S251/1 - XX $ S451/1 - XX $ S656/1 - XX $ S756/1 - XX $ S105/2 - XX $ S151/2 - XX $ S251/2 - XX $ S451/2 - XX $ S656/2 - XX $ S756/2 - XX $ S105/26 - XX $ S151/26 - XX $ S251/26 - XX $ S451/26 - XX $ S656/26- XX $ S756/26 - XX $ S105/5 - XX $ S151/5 - XX $ S251/5 - XX $ S451/5 - XX $ S656/5 - XX $ S756/5 - XX $ S105/3- XX $ S151/3 - XX $ S251/3 - XX $ S451/3 - XX $ S656/3 - XX $ S756/3 - XX $ S105/16 - XX $ S151/16 - XX $ S251/16 - XX $ S451/16 - XX $ S656/16 - XX $ S756/16 - XX $ Reversing for Individually Compensated Motors 16 S105/27- XX $ S151/27 - XX $ S251/27 - XX $ S451/27 - XX $ S656/27 - XX $ S756/27 - XX $ J14 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

15 TYPE: STEP SWITCHES WITH 0-POSITION 2 STEPS Front Plate / Diagram 16 V105/10 - XX $ V151/10 - XX $ V251/10 - XX $ V451/10 - XX $ V656/10 - XX $ V756/10 - XX $ V105/44 - XX $ V151/44 - XX $ V251/44 - XX $ V451/44 - XX $ V656/44 - XX $ V756/44 - XX $ Pole 16 V105/170 - XX $ V151/170 - XX $ V251/170 - XX $ V451/170 - XX $ V656/170- XX $ V756/170 - XX $ J 15 4 Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ Pole 16 V105/1201- XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J15

16 TYPE: STEP SWITCHES WITH 0-POSITION 3 STEPS STEP SWITCHES WITH 0-POSITION 3 STEPS Front Plate / Diagram 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ V105/17 - XX $ V151/17 - XX $ V251/17 - XX $ V451/17 - XX $ V656/17 - XX $ V756/17 - XX $ J 16 3 Pole 16 V105/18 - XX $ V151/18 - XX $ V251/18 - XX $ V451/18 - XX $ V656/18- XX $ V756/18 - XX $ Pole 16 V105/1199- XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ J16 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

17 TYPE: STEP SWITCHES WITH 0-POSITION 4 STEPS STEP SWITCHES WITH 0-POSITION 4 STEPS Front Plate / Diagram 16 V105/12 - XX $ V151/12 - XX $ V251/12 - XX $ V451/12 - XX $ V656/12 - XX $ V756/12 - XX $ V105/45 - XX $ V151/45 - XX $ V251/45 - XX $ V451/45 - XX $ V656/45 - XX $ V756/45 - XX $ J 17 3 Pole 16 V105/55 - XX $ V151/55 - XX $ V251/55 - XX $ V451/55 - XX $ V656/55- XX $ V756/55 - XX $ Pole 16 V105/1200- XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J17

18 TYPE: STEP SWITCHES WITH 0-POSITION 5 STEPS STEP SWITCHES WITH 0-POSITION 5 STEPS Front Plate / Diagram 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ J V105/171 - XX $ V151/171 - XX $ V251/171 - XX $ V451/171 - XX $ V656/171 - XX $ V756/171 - XX $ Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/1195- XX $ V756/ XX $ J18 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

19 TYPE: STEP SWITCHES WITH 0-POSITION 6 STEPS STEP SWITCHES WITH 0-POSITION 6 STEPS Front Plate / Diagram 16 V105/60 - XX $ V151/60 - XX $ V251/60 - XX $ V451/60 - XX $ V656/60 - XX $ V756/60 - XX $ V105/172 - XX $ V151/172 - XX $ V251/172 - XX $ V451/172 - XX $ V656/172 - XX $ V756/172 - XX $ J 19 3 Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/1196- XX $ V756/ XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J19

20 TYPE: STEP SWITCHES WITH 0-POSITION 7/8/9 STEPS STEP SWITCHES WITH 0-POSITINO 7/8/9 STEPS Step switches with 0-Position - 7 steps 16 V105/64 - XX $ V151/64 - XX $ V251/64 - XX $ V451/64 - XX $ V656/64 - XX $ V756/64 - XX $ Front Plate / Diagram J V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ Step switches with 0-Position - 8 steps 16 V105/122 - XX $ V151/122 - XX $ V251/122 - XX $ V451/122 - XX $ V656/122- XX $ V756/122- XX $ Step switches with 0-Position - 9 steps 16 V105/96- XX $ V151/96 - XX $ V251/96 - XX $ V451/96 - XX $ V656/96 - XX $ V756/96 - XX $ J20 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

21 TYPE: STEP SWITCHES WITH 0-POSITION 10/11 STEPS STEP SWITCHES WITH 0-POSITINO 10/11 STEPS Step switches with 0-Position - 10 steps 16 V105/108 - XX $ V151/108 - XX $ V251/108 - XX $ V451/108 - XX $ V656/108 - XX $ V756/108 - XX $ Front Plate / Diagram J 21 Step switches with 0-Position - 11 steps 16 V105/113 - XX $ V151/113 - XX $ V251/113 - XX $ V451/113 - XX $ V656/113 - XX $ V756/113 - XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J21

22 TYPE: STEP SWITCHES WITH NO 0-POSITION 4 STEPS STEP SWITCHES WITH NO O-POSITION 4 STEPS Front Plate / Diagram 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ V105/105 - XX $ V151/105 - XX $ V251/105 - XX $ V451/105 - XX $ V656/105 - XX $ V756/105 - XX $ J 22 3 Pole 16 V105/168 - XX $ V151/168 - XX $ V251/168 - XX $ V451/168 - XX $ V656/168- XX $ V756/168 - XX $ Pole 16 V105/1189- XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ Pole 16 V105/1192- XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/1192- XX $ J22 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

23 TYPE: STEP SWITCHES WITH NO 0-POSITION 4 STEPS STEP SWITCHES WITH NO O-POSITION 4 STEPS Front Plate / Diagram 6 Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ Separate s 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ J 23 Separate s 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/1181- XX $ V756/ XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J23

24 TYPE: STEP SWITCHES WITH NO 0-POSITION 5 STEPS STEP SWITCHES WITH NO 0-POSITION 5 STEPS Front Plate / Diagram 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ J V105/162 - XX $ V151/162 - XX $ V251/162 - XX $ V451/162 - XX $ V656/162 - XX $ V756/162 - XX $ Pole 16 V105/ XX $ V151/ XX $ V251/1184- XX $ V451/ XX $ V656/1184- XX $ V756/ XX $ Pole 16 V105/1190- XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/1190- XX $ J24 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

25 TYPE: STEP SWITCHES WITH NO 0-POSITION 6 STEPS STEP SWITCHES WITH NO 0-POSITION 6 STEPS Front Plate / Diagram 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ V105/163 - XX $ V151/163 - XX $ V251/163 - XX $ V451/163 - XX $ V656/163 - XX $ V756/163 - XX $ J 25 3 Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/1185- XX $ V756/ XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J25

26 TYPE: STEP SWITCHES WITH NO 0-POSITION 7 STEPS STEP SWITCHES WITH NO 0-POSITION 7 STEPS Front Plate / Diagram 16 V105/157- XX $ V151/157 - XX $ V251/157 - XX $ V451/157 - XX $ V656/157 - XX $ V756/157 - XX $ J V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/1186- XX $ V756/ XX $ J26 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

27 TYPE: STEP SWITCHES WITH NO 0-POSITION 8 STEPS STEP SWITCHES WITH NO 0-POSITION 8 STEPS Front Plate / Diagram 16 V105/106- XX $ V151/106 - XX $ V251/106 - XX $ V451/106 - XX $ V656/106 - XX $ V756/106 - XX $ V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ J 27 3 Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/1187- XX $ V756/ XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J27

28 TYPE: STEP SWITCHES WITH NO 0-POSITION 9/10/11 /12 STEPS STEP SWITCHES WITH NO 0-POSITION 9/10/11/12 STEPS Step Switches without 0-Position - 9 Steps 16 V105/158 - XX $ V151/158 - XX $ V251/158 - XX $ V451/158 - XX $ V656/158 - XX $ V756/158 - XX $ Front Plate / Diagram J 28 Step Switches without 0-Position - 10 Steps 16 V105/153 - XX $ V151/153- XX $ V251/153 - XX $ V451/153 - XX $ V656/153 - XX $ V756/153 - XX $ Step Switches without 0-Position - 11 Steps 16 V105/159- XX $ V151/159 - XX $ V251/159- XX $ V451/159 - XX $ V656/159- XX $ V756/159 - XX $ Step Switches without 0-Position - 12 Steps 16 V105/160- XX $ V151/160 - XX $ V251/160 - XX $ V451/160 - XX $ V656/160 - XX $ V756/160- XX $ J28 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

29 TYPE: GROUP SWITCHES, 2 GROUPS IN SERIES GROUP SWITCHES, 2 GROUPS IN SERIES Front Plate / Diagram 16 V105/1206- XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/ XX $ V756/ XX $ V105/ XX $ V151/ XX $ V251/1207- XX $ V451/ XX $ V656/ XX $ V756/ XX $ J 29 3 Pole 16 V105/ XX $ V151/ XX $ V251/ XX $ V451/ XX $ V656/1208- XX $ V756/ XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J29

30 TYPE: GROUP SWITCHES, 2 GROUPS GROUP SWITCHES, 2 GROUPS Front Plate / Diagram 16 V105/46- XX $ V151/46 - XX $ V251/46 - XX $ V451/46 - XX $ V656/46 - XX $ V756/46 - XX $ J V105/ XX $ V151/ XX $ V251/1204- XX $ V451/ XX $ V656/ XX $ V756/ XX $ Pole 16 V105/174- XX $ V151/174 - XX $ V251/174 - XX $ V451/174 - XX $ V656/174- XX $ V756/174 - XX $ J30 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

31 TYPE: GROUP SWITCHES, 3 GROUPS GROUP SWITCHES, 3 GROUPS Front Plate / Diagram 16 V105/38- XX $ V151/38 - XX $$ V251/38 - XX $ V451/38 - XX $ V656/38 - XX $ V756/38 - XX $ V105/ XX $ V151/ XX $ V251/1205- XX $ V451/ XX $ V656/ XX $ V756/ XX $ J 31 3 Pole 16 V105/30- XX $ V151/30 - XX $ V251/30 - XX $ V451/30 - XX $ V656/30- XX $ V756/30 - XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J31

32 TYPE: CODE SWITCHES, BINARY CODE CODE SWITCHES, BINARY CODE Front Plate / Diagram V105/1403- XX $ V151/ XX $ V251/ XX $ Compliment 16 V105/1404- XX $ V151/ XX $ V251/ XX $ J Compliment 16 V105/1405- XX $ V151/ XX $ V251/ XX $ V105/1406- XX $ V151/ XX $ V251/ XX $ Compliment 16 V105/1407- XX $ V151/ XX $ V251/ XX $ Compliment 16 V105/1408- XX $ V151/ XX $ V251/ XX $ J32 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

33 TYPE: CODE SWITCHES, BCD CODE CODE SWITCHES, BCD CODE Front Plate / Diagram V105/1409- XX $ V151/ XX $ V251/ XX $ Compliment 16 V105/1410- XX $ V151/ XX $ V251/ XX $ J Compliment 16 V105/1411- XX $ V151/ XX $ V251/ XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J33

34 TYPE: VOLTMETER SELECTOR VOLTMETER SELECTOR Front Plate / Diagram 3 Phases to N 16 V105/2- XX $ Line Voltages 16 V105/3- XX $53.00 J 34 3 Line Voltages 1 Phase to N 16 V105/4- XX $ Line Voltages 3 Phases to N 16 V105/49- XX $74.00 J34 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

35 TYPE: VOLTMETER SELECTOR VOLTMETER SELECTOR Front Plate / Diagram 3 Line Voltages for 2 Mains 16 V105/188- XX $ Line Voltages 16 V105/1144- XX $53.00 J 35 3 Line Voltages 3 Phase to N 16 V105/1210- XX $74.00 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J35

36 TYPE: AMMETER SELECTOR AMMETER SELECTOR Front Plate / Diagram 3 Transformer Circuits 16 V105/147- XX $ Transformer Circuits 16 V105/1145- XX $ J 36 3 Voltages 3 Currents 16 V105/1146- XX $ Transformer Circuits 16 V105/1212- XX $74.00 J36 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

37 TYPE: AMMETER SELECTOR AMMETER SELECTOR Front Plate / Diagram 4 Transformer Circuits 16 V105/1214- XX $ Transformer Circuits 16 V105/1215- XX $74.00 J 37 3 Transformer Circuit 16 V105/1216- XX $ V105/1217- XX $ Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J37

38 TYPE: SINGLE-PHASE STARTER SWITCHES SINGLE-PHASE STARTER SWITCHES Front Plate / Diagram With Starter Capacitor 16 E105/1- XX $ E151/1- XX $ E251/1- XX $ With Starter Capacitor 20 E151/2- XX $ E251/2- XX $ J 38 2 Reversing 16 E105/3- XX $ E151/3- XX $ E251/3- XX $ Reversing 20 E151/4- XX $ E251/4- XX $ With Running Capacitor 16 E105/5- XX $ E151/5- XX $ E251/5- XX $ J38 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

39 HANDLE & MOUNTING CODE - CAM SWITCHES 3 mounting styles available for cam switches (see below). Replace XX suffix from cam part number with letter suffix below. (Example: A251/6-AB, Front Mount 4-hole) Standard black lever handle used on all cam switches (custom handles are available on request.) of switch includes handle and mounting style. Cam switches available with enclosure; polycarbonate or aluminum. Consult factory. Front Mount; 4-hole* Model / Series Suffix* 105, 151 AA 251, 451 AB 656, 756 AC Base Mount; Screw Fixing* J 39 Model / Series Suffix* 105, 151 PB 251, 451 PC 656, 756 PD Central Mount; 1-Hole (22.5mm or 30.5mm)* Model / Series Suffix* 105, 151, 251 CA 451, 656, 756 Not Available * All cam handles Black/Grey in color. Consult factory for Red/Yellow. See page J40 for dimensions. Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J39

40 HANDLE & MOUNTING DIMENSIONS Front Mount; 4-Hole Dimensions B2 B1 Dimension (Inches) L By Switch s Type A B1 B2 D F H S Base Mount; Screw Fixing Dimensions J 40 Dimension (Inches) L By Switch s Type A1 A2 B3 D F H S Central Mount; 1 Hole Dimensions (22.5mm or 30.5mm) Dimension (Inches) L By Switch s Type D F H S J40 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

41 CAM SWITCH ENCLOSURES All cam switches can be designated to an enclosure. Enclosures are available in polycarbonate or aluminum cast-iron. Consult factory for pricing of a complete enclosed switch. Dimensional Data Dimensions are enclosure only; does not include the handle dimension. Polycarbonate (IP65 rated) Series L x W x D (mm) Mounting Hole to Hole Enclosure Type x 90.5 x mm I1 - D - NL x 90.5 x mm I1 - D - HL4 151, 251, ML1 115 x 115 x mm I2 - D- NL4 151, 251, ML1 115 x 115 x mm I2 - D - HL4 451, ML2 145 x 145 x mm I3 - D - NL4 451, ML2 145 x 145 x mm I3 - D - HL4 656*, 756* 300 x 300 x mm I7N 656*, 756* 300 x 300 x mm I7H * Clear polycarbonate cover face J 41 Aluminum Cast-Iron (IP54 rated) Series L x W x D (mm) Mounting Hole to Hole Enclosure Type 105, x 105 x mm A18 151, x 121 x mm A19 * Consult factory for additional sizes Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J41

42 CAM SWITCH ACCESSORIES Extension Terminal Front Plates For Central 2 & 3 Hole Mounting Type Extension Terminals Catalog No. AS *C.F. * C.F. - Consult Factory items will vary in price according to switch configuration. (A) Base Plate (black) (B) Insert Plate (silver) Blade Terminal Type Catalog No. Blade Terminals F *C.F. * C.F. - Consult Factory items will vary in price according to switch configuration. Type Color Size Dimension Catalog No. A Black 0 30 x 51mm EB91 $3.00 A Black 1 48 x 69mm EB64 $3.00 B Silver 0 ES $3.00 B Silver 1 ES1 $3.00 Front Plates Size 1 & Size 2 Auxiliaries J 42 Type Catalog No. PE Terminals PE $11 N Terminals N $11 Color Size Dimension Catalog No. Yellow 1 66 x 89mm MSY $8.00 Grey 2 86 x 108mm MSG $8.00 Protection Covers Base & Rear Mounting Up To Series 451 Type Catalog No. Protection Covers DH *C.F. * C.F. - Consult Factory items will vary in price according to switch configuration. Extension Shafts (A) (B) Voltage Release - Loss of Voltage Type Catalog No. Voltage Release U *C.F. 24V AC, 120V AC, 240V AC * C.F. - Consult Factory items will vary in price according to switch configuration. Type Size Catalog No. A 18mm (max. 5 pcs.) AL18 $3.00 B 65-80mm AL-65 $16.00 B mm AL165 $19.00 B mm AL265 $23.00 B mm AL365 $31.00 J42 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

43 Name: Company: P.O. Box: Street Address: City, State, Zip Telephone # Fax # address SPECIAL ORDER FORM send to: Springer Controls Co., Inc Chester Road Yulee, Florida Phone: (904) Fax: (904) Front Plate Swiching Angle Complete Rotation J 43 Switch Position Marking Degree Key Removable Closed Closed Without Interruption Wiping Spring Return Series: Accessories: Application: Quantity: Date: Writer: Factory Type: Factory Order No.: Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904) J43

44 NOTES J 44 J44 Springer Controls Company Chester Road, Yulee, FL (904) Fax: (904)

DISCONNECT SWITCHES (16 TO 630 amp)

DISCONNECT SWITCHES (16 TO 630 amp) I DISCONNECT SWITCHES (16 TO 630 amp) Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We carry a complete line of UL approved, CSA listed, Disconnect

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

AC Switches: ML & MN Series DC Switches: MDC1A Series

AC Switches: ML & MN Series DC Switches: MDC1A Series AC Switches: ML & MN Series DC Switches: MDC1A Series Australian & New Zealand Distributor Leveltec Engineering Pty Ltd Gloucester P:+612 6558 9264 F:+612 6558 1002 Sydney P:+612 9299 5630 F:+612 6558

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

Switch Disconnectors

Switch Disconnectors Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles

More information

Control and Load Switch Specifications Bulletin Number 194E, 194L

Control and Load Switch Specifications Bulletin Number 194E, 194L Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

LCIRCUIT BREAKERS. Jtec UL (Motor Disconnect) General Information...L2 Trip Curves & Dimensions...L3

LCIRCUIT BREAKERS. Jtec UL (Motor Disconnect) General Information...L2 Trip Curves & Dimensions...L3 Index L Springer Controls carries a complete line of Techna Miniature Circuit Breakers rated from 0.5 amps through 63.0 amps. Applications include usage in UL508A panels, motor group installations, motor

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES DESIGN FEATURES Double break contacts Polycarbonate shroud for wired terminal protection included Excellent switching & high short circuit capacity Compact and reliable Easy installation Front, rear and

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Junction boxes for control, monitoring and control panel Ex tb

Junction boxes for control, monitoring and control panel Ex tb Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,

More information

B Mini Contactor V Hz

B Mini Contactor V Hz ABB B7-30-10-80 Mini Contactor 220-240V 40-450Hz General Information Extended Product Type Product ID B7-30-10-80 GJL1311001R8100 EAN 4013614150197 Catalog Description Long Description B7-30-10-80 Mini

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Load and Motor Switches, Load-Break Switches Series 8549

Load and Motor Switches, Load-Break Switches Series 8549 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Pick-off terminal block Auxiliary

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals Terminal Blocks 2013 Product Catalog Terminal Block Supplement Introduction 8WH6 ipo Plug-In Terminals 8WH6 ipo Installation Terminals 8WH2 Spring-Loaded Terminals 1 2 3 4 8WH 8WH5 Combination Plug-In

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Manual motor starter magnetic only MO325

Manual motor starter magnetic only MO325 Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47. Snap-action switches Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.en Snap-action switches, S847 Series Dual changeover

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

FOOT SWITCHES

FOOT SWITCHES - 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,

More information

General_technical_data Series

General_technical_data Series Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 Ø48. Panel Door

Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 Ø48. Panel Door Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 O I II Ø4 Panel Door on to the best GEERAL Contents General IDEX Page o. Technical Data 1 ing Programmes 2 Front 3 Rear 5 Plastic Enclosure Metal Enclosure Accessories

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Control switch/load disconnect switch Series 8008

Control switch/load disconnect switch Series 8008 > s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

8WH6 ipo Installation Terminals

8WH6 ipo Installation Terminals /2 Introduction /4 8WH through-type terminals /6 8WH through-type screw terminals /8 8WH N-conductor isolating terminals /10 8WH N-conductor isolating screw terminals /12 8WH installation terminals More

More information

Safety Switches Series 8537

Safety Switches Series 8537 Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part

More information

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring: SERIES D DISCONNECT SWITCHES 1 Amp 0 Amp 00 & 0 Volt Load Make/Load Break Positive Opening Compact Size Modular Construction Horse Power Rated Custom Versions Featuring: Auto Alignment Shaft Wide Handle

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Cam switches. CA Series

Cam switches. CA Series Cam switches CA Series CA Series Overview The range of cam switches CA series includes ratings from to 6A and insulation voltages of 69. The CA series offers IP terminals protection degree (it s possible

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green Female socket block, Screw connection, No. of poles: 12, Width: 45.72 mm, Colour: Green Business data Connector version Free connector Packaging unit 50 Quantity unit PC Packaging type Carton Type of banding

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: alligator clip auxiliary

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches es Series es... 2 Assemblies... 11 s... 15 Accessories... 25 Technical Information... 26 Dimensions... 31 Series R-Line es... 34 s... 39 Accessories... 40 Technical Information... 41 Dimensions... 42 es

More information

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102 Overloadrelay,10-16A,1N/O+1N/C Partno. ZB12-16 Articleno. 290168 CatalogNo. XTOB016BC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Frame size ZB12 Phase-failure sensitivity IEC/EN 60947,

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal