Replacement Parts. Applies to: Separated-Combustion Models SC, SCE, SSCBL, SSCDBL. Index. Form P-SC (03-18) IMPORTANT. Model SC Duct Furnace

Size: px
Start display at page:

Download "Replacement Parts. Applies to: Separated-Combustion Models SC, SCE, SSCBL, SSCDBL. Index. Form P-SC (03-18) IMPORTANT. Model SC Duct Furnace"

Transcription

1 IMPORTNT 1. lways include complete heater model and serial number so that any specification change can be considered for parts shipment. It can save time and expense. 2. Specifications are subject to change without notice. 3. We reserve the right to substitute functional replacements. 4. Order by Part No.; not Heater Option esignation. Form P-S (03-18) Obsoletes Form P-S (03-17) Replacement Parts pplies to: Separated-ombustion Models S, SE, SSL, SSL Index ir Shutter (burner rack) 11 lower ir Flow Switch 5 larm ell 12 mplifiers 6 Heat Exchanger Tube affles 10 earing Mounting 30 earings 28 elt 20, 21, 22, 24, 25 Motor Mounting olts 30 urner Rack and omponents 10 lower abinet Parts 27 Interior abinet Parts 9 abinet Parts 26, 28 Exhaust ap 3 Inlet ir ap 3 apacitor 9 arryover 10 arryover Regulator 11 ombustion ir Pressure Switch 5 oncentric dapter ssy 3 ondensate rain Kit 26 Motor ontactor 6 Mixed ir ontroller 32 Outside ir ontroller 32 amper Motor 31 amper Rod 31 ampers and ontrols 31 ate of Manufacture 2 ate Series was Introduced or Recertified 3 (4-20 ma) interface module 32 isconnect Switch 7 rive Options and omponents 20 uctstat 5 uctstat Sensor 5 E Electrical omponents 4 Screened Exhaust ap 3 F Rubber Feet and Hardware (blower motor) 28 Filters 27, 30 Firestat 5 Flue ollection ox 9 Freezestat 5 Frequency rives 17 Fuse 6 Fuseholder 6 G Grommet 26 Inlet Guard 3 H Hand Quadrant 32 Heat Exchanger 9 Heat Exchanger irectional ir affles 9 I Ignition ontrollers 5 L oor Latch Kit 29 Light 8 Reverse Flow Limit 6 Limit ontrol 4 amper Linkage Parts 32 Louvers 26 M Special Manifold omponents 12 Manifold 11 lower Motor 13, 14, 15, 16, 17, 18, 19, 20 amper Motor 31 Gear Motor 9 Motor djustment racket 28 Motor Support 28, 29 Mounting Support 26 O urner Orifices 10 onvenience Outlet 6 Overload 14, 16 Overloads 17 P Paint 26 Replacement Parts Tag 3 Pilots 12 Potentiometer 32 Low Gas Pressure Switch 12 Pressure Null Switch 32 irty Filter Pressure Switch 7 High Gas Pressure Switch 6, 12 Low Gas Pressure Switch 6 Pulley 20, 21, 22, 24, 25 R Rating Plate 2 2-Speed Motor Speed Selector Relay 6 Relay 4, 9, 12 Remote onsole 7 S ischarge Sensor for Modulating Gas 6 ir Flow Switch Sensor 30 Serial Number 2 lower Shaft 28 Signal onditioner 6 Silicone Sealant 3 Starter 14 Holding oils for IE Starters 17 Starters 13, 14, 15, 16, 17, 18, 19, 20 Summer/Winter Switch 5 Toggle Switches 7 uxiliary End Switch 32 Gas Pressure Switch 6 Switch 8 T Temperature ontrol 6 Temperature Selectors 6 Terminal lock 4 Thermostats 7 Transformer 4, 7, 13 V Fluid Power Valve 13 Gas Valve 10 Manual Gas Valves 11 Variable Frequency rives 13 Venter and Flue uct Parts 8 Venter Motor and Wheel 8 Vent Limiter 6 Vent Terminal/ombustion ir Intake omponents 3 Vent Valve 13 dditional References: (See your factory distributor for the following catalogs and instruction manuals) Subject... Form Service - Replacement Gas Valves, Ignition ontrollers & Maxitrol Parts... P-VLVES Service - onverting to Other Gases... P-G Service - Replacement Parts for Optional Evaporative ooling Module... P-RE Installation/Operation - Model Series S, uct Furnace... I-S Installation/Operation - Model Series SE Packaged uct Furnace/lower...I-SE Installation/Operation - Model Series SSL and SSL Packaged Systems...I-SSL Installation/Operation - Vent Terminal/ombustion ir Packages...I-OPT-V Installation/Operation - Optional Evaporative ooling Modules...I-OPT-E Model S uct Furnace Model SE lower/furnace Packaged System Model SSL Packaged System with "L" Type lower abinet and 1, 2, or 3 Furnace Sections Model SSL Packaged System with two "L" Type lower abinets and 2, 4, or 6 Furnace Sections (discontinued 2011) USTOMER QS GENY ONVERGENT QULITY SYSTEM PROUT PROESS (discontinued 2011) Form P-S (03-18) PN269822R13, Page 1 STRT-UP WRRNTY

2 Rating Plate and Serial No. MERER, P. US ME IN MEXIO SEPRTE OMUSTION SYSTEM UT FURNE TEGORY III FOR INUSTRIL/OMMERIL USE ONLY NSI Z83.8 [ ] - [ ] S 2.6 [ ' ] - [ ' ] UT FURNE MOEL [ ] [ ] SERIL NO. [ ] WIRING IGRM NUMER [ Z ] [ E ] VOLTS [ E ] PH [ E ] HZ MXIMUM TOTL INPUT [ E ] MPS TYPE OF GS: [ F ] ORIFIE SIZE [ J ] RILL HS EEN FTORY JUSTE FOR USE T [ H ] FEET [ I ] METERS OF LTITUE SE LEVEL LT. JUSTE NORML INPUT [ R ] [ K ] TU/HR. THERML OUTPUT PITY [ S ] [ L ] TU/HR. MINIMUM INPUT(2,M,MV MOELS) [ T1 or T2 ] [ M ] TU/HR. NORML MNIFOL PRESSURE [ N ] IN.W.. MIN. PERMISSILE GS SUPPLY PRESSURE FOR PURPOSE OF INPUT JUSTMENT. [ O ] IN.W.. MXIMUM THROUGHPUT [ P ] FM. MINIMUM THROUGHPUT [ Q ] FM. LERNES TO OMUSTILE ONSTRUTION: FLUE ONN. -6", SERVIE SIE-WITH OF UNIT, OPP. SIE-6", OTTOM-6", TOP-6" MY E INSTLLE ON NONOMUSTILE FLOORS. INSTLL ON THE POSITIVE PRESSURE SIE OF IR-IRULTING LOWER. THIS UNIT MY E INSTLLE OWNSTREM FROM REFRIGERTION SYSTEM (USE RIN OPTION S1). THIS UNIT MY E VENTE VERTILLY WHEN USING ONENTRI PTOR SSEMLY, PRT NO , SUPPLIE Y MNUFTURER. FOR LTERNTE INSTLLTIONS USE THE LTEST EITIONS OF THE PPROPRITE STNR LISTE ELOW: FOR IRRFT HNGRS USE STNR NSI/NFP 409 FOR PRKING STRUTURES USE STNR NSI/NFP 88 FOR REPIR GRGES USE STNR NSI/NFP 88 THIS UNIT IS FOR ONNETION MINIMUM OF 10'-0" OR THE FOLLOWING MXIMUM LENGTHS: [ X ] IN. PIPE I. [ Y ] FEET MX. OMINE LENGTH Key to Rating Plate odes - = NSI ode and ate '-' = S ode and ate = Model No. = ate of Manufacture = Serial No. E = Volts, Phase, Hz, mps F = Type of Gas H = ltitude (feet) I = ltitude (meters) J = Orifice Size K = Normal Input ltitude djusted (TUH) L = Thermal Output ltitude djusted (TUH) M = Minimum Input ltitude djusted (TUH) N = Normal Manifold Pressure ("w.c.) O = Minimum Gas Supply Pressure ("w.c.) P = Maximum ir Throughput (FM) Q = Minimum ir Throughput (FM) R = Normal Input Sea Level (TUH) S = Thermal Output Sea Level (TUH) T = Minimum Input Sea Level (TUH) X = Pipe iameter (inches) Y = Maximum ombined Length (inches) Serial No. ecoding - LL Models EFORE June, 2015 Serial No. Sample: 66 H5 N Element Key No.: Key: 1 = ate of Manufacture (See table below.) 2 = Type of pilot system (see Form P-VLVES) 3 = Type of gas valve (see Form P-VLVES) 4 = Gas (N = natural; L = propane) 5 = onsecutive number (identification only) Serial No. ecoding - LL Models FTER June, 2015 Serial No. Sample: OF Element Key No.: Key: 1 = ate of Manufacture (See table below.) 2 = Plant of Manufacture (3060 = Mercer; 3062 = Monterrey) 3 = onsecutive number First Element of the Serial Number - ate of Manufacture Year Jan Feb Mar pr May June July ug Sept Oct Nov ec 1980 F F F F FE FF FG FH FI FJ FK FL 1981 G G G G GE GF GG GH GI GJ GK GL 1982 H H H H HE HF HG HH HI HJ HK HL 1983 I I I I IE IF IG IH II IJ IK IL 1984 J J J J JE JF JG JH JI JJ JK JL 1985 K K K K KE KF KG KH KI KJ KK KL 1986 L L L L LE LF LG LH LI LJ LK LL 1987 M M M M ME MF MG MH MI MJ MK ML 1988 N N N N NE NF NG NH NI NJ NK NL 1989 O O O O OE OF OG OH OI OJ OK OL 1990 P P P P PE PF PG PH PI PJ PK PL 1991 Q Q Q Q QE QF QG QH QI QJ QK QL 1992 R R R R RE RF RG RH RI RJ RK RL 1993 S S S S SE SF SG SH SI SJ SK SL 1994 T T T T TE TF TG TH TI TJ TK TL 1995 U U U U UE UF UG UH UI UJ UK UL 1996 V V V V VE VF VG VH VI VJ VK VL 1997 W W W W WE WF WG WH WI WJ WK WL 1998 X X X X XE XF XG XH XI XJ XK XL 1999 Y Y Y Y YE YF YG YH YI YJ YK YL 2000 Z Z Z Z ZE ZF ZG ZH ZI ZJ ZK ZL 2001 E F G H I J K L 2002 E F G H I J K L 2003 E F G H I J K L 2004 ` E F G H I J K L 2005 E E E E EE EF EG EH EI EJ EK EL 2006 F F F F FE FF FG FH FI FJ FK FL 2007 G G G G GE GF GG GH GI GJ GK GL 2008 H H H H HE HF HG HH HI HJ HK HL 2009 I I I I IE IF IG IH II IJ IK IL 2010 J J J J JE JF JG JH JI JJ JK JL 2011 K K K K KE KF KG KH KI KJ KK KL 2012 L L L L LE LF LG LH LI LJ LK LL 2013 M M M M ME MF MG MH MI MJ MK ML 2014 N N N N NE NF NG NH NI NJ NK NL 2015 O O O O OE OF OG OH OI OJ OK OL 2016 P P P P PE PF PG PH PI PJ PK PL 2017 Q Q Q Q QE QF QG QH QI QJ QK QL 2018 R R R R RE RF RG RH RI RJ RK RL 2019 S S S S SE SF SG SH SI SJ SK SL 2020 T T T T TE TF TG TH TI TJ TK TL Form P-S (03-18) PN269822R13, Page 2

3 lower abinet Rating Plate on ertified Packaged Units Key to lower abinet Plate MERER, P., U.S PKGE UT FURNE FOR INUSTRIL/OMMERIL USE ONLY ESIGN ERTIFIE FOR.G. REQUIREMENTS UNER [ ] PKGE UT FURNE STNR MOEL [ ] [ ] SERIL NO. [ ] HP [ E ] VOLTS [ E ] PH [ E ] HZ MXIMUM TOTL INPUT [ E ] MPS IF EQUIPPE WITH RE OPTION, [ V ] MPS EQUIPPE FOR OPERTION T N IR FLOW OF [ F ] SFM GINST STTI PRESSURE OF [ G ] INHES WTER OLUMN. RIVE NO. [ H ] WIRING IGRM [ I ] SEE MNUFTURER'S INSTRUTIONS FOR OTHER IR FLOW PITIES. FILTERS, WHEN USE, MUST E INSTLLE EXTERNL TO THE HETER SING. REFER TO THE RTING PLTE OF THE UT FURNE FOR ITIONL INFORMTION. ate Series was Introduced or Re-certified (may affect parts selection) Series changes indicate when that Model was recertified by the approval agency. The Series is identified in the Model No. of the unit. The number following the model of the heater is the series number (Example: S300-6, "6" is the Series No.). Replacement parts may be affected by the introduction of a new series. NOTE: Series 6 had significant changes. Replacement parts specific to Series 1, 3, and 5 are not listed in this manual and are no longer available. Introduction - Month/Year (Serial No. ate ode) of Furnace ertification Models Series 1 Series 3 Series 5 Series 6 S 3/74 (Z) 9/82 (HI) 4/89 (O) 10/93 (SJ) S 3/74 (Z) 9/82 (HI) 4/89 (O) 10/93 (SJ) NSI S 3/74 (Z) 9/82 (HI) 4/89 (O) 10/93 (SJ) Std SE 8/74 (ZH) 9/82 (HI) 4/89 (O) 10/93 (SJ) SSL 1/92 (R) 1/97 (W).G.. Std S 3/75 () /93 (SJ) S 3/75 () 9/82 (HI) 1/91 (Q) 10/93 (SJ) S 3/75 () 9/82 (HI) 1/91 (Q) 10/93 (SJ) SE -- 9/82 (HI) 1/91 (Q) 10/93 (SJ) SSL 1/97 (W) = Standard = Model = ate of Manufacture = Motor Horsepower Identification Plate on lower abinets Manufactured Prior to Package ertification (see dates below) HP odes: E = Volts/Phase/Hertz/mps F = SFM G = Static Pressure (w.c.) H = rive M Option ode I = Wiring iagram No. MOEL NUMER SERIL NUMER RIVE NO. WIRING IGRM NO. FM T IN. W.. MX. E.S.P. N HP VOLTS PHSE HERTZ MPERES Single-Speed Motors 2-Speed Motors ode HP ode HP / / / / / / / / / Model SSL replacement parts are not specifically listed. Look for the equivalent SSL Model as listed below. SSL onsists of: 800 (2) Model SSL 400 Packaged Systems 1000 (2) Model SSL 500 Packaged Systems 1200 (2) Model SSL 600 Packaged Systems 1400 (2) Model SSL 700 Packaged Systems 1600 (2) Model SSL 800 Packaged Systems Model SSL onfiguration Two L lower abinets - ll Sizes 2 Furnace Sections - Size Furnace Sections - Sizes 1000, 1200, 1400, 1600 NOTES: Manufacture of Models S and S was discontinued in Replacement parts are not listed in this manual and may not be available. If a part is needed, contact your distributor for availability. Manufacture of Model SE was discontinued in Replacement Parts Tag Each unit may have a replacement parts tag that includes the Model No. and the Serial No. as well as a list of original common replacement parts. lways provide the full model and serial numbers when ordering replacement parts. Vent Terminal/ombustion ir Intake omponents - applies to all "S" Series Models (one per furnace) ode Qty escription omplete Horizontal Vent Terminal/ombustion ir Kit (Same as Option 6) includes odes 3, 4, 5, 6, 7, omplete Vertical Vent Terminal/ombustion ir Kit (Same as Option 2) includes odes 3, 4, 6, 8, 9, 10 omponents: oncentric dapter ox ssy (2 & 6) 4 2 oncentric dapter ox racket (2 & 6) not illustrated Inlet Guard for Horizontal (Option 6) #10-16 x 1/2" lg Screws to attach OE Screened Exhaust for Horizontal (Option 6) Inlet ir ap for Vertical (Option 2) Exhaust ap for Vertical (Option 2) Tube of High Temperature (450 F) Silicone Sealant (not illustrated) ode 3 - oncentric dapter ssy for Separated ombustion Installation -- required on all Models ode 5 - Inlet Guard for Horizontal Inlet (replaces inlet screen) ode 7 - Screened Exhaust ap for Horizontal Vent Heater Side ode 8 - Inlet ir ap for Vertical Inlet ode 9 - Exhaust ap for Vertical Vent Terminal Side Form P-S (03-18) PN269822R13, Page 3

4 Electrical omponents Locations - ontrol Side (See parts illustrated on pages 4-7.) odes 12 and 12 Terminal lock, Terminal lock dapter, ode 13 - ontrol and amper Transformers , 115/24/20V, asler #E WR , 115/24/40V, asler #E W , 208/230/24/40V, asler #E , 460/24/40V, asler #E ode 14 - Time elay Relay, To replace time delay relay ( or ) used on product manufactured prior to 2/2010, order replacement kit, ode 17 - Relay, and For units manufactured prior to 9/2011, order a replacement kit, , to replace relay 14747, or Terminal locks 17 - Relay, (Opts 8, 9, G21) 18 - Time elay Relay (Opts G 39, 40) 13 - Transformer 40V ode 15 - SPST Time elay Relay (fan/blower control on units mfgd beginning 12/04), , Thermodisc I2S Venter ssy ode 18 - Time elay Relay, SPT, 24V, Thermodisc 12S30, Used in Option G39 and G40 urner Rack and Manifold For units manufactured prior to 12/04, the temperature activated fan control is no longer available. Order Replacement Kit, ode 16 - SPT Relay, RM , Same as Option G3 & part 1 of Option G ode 19 - Time elay Relay, T & gastat TM1UL, Used in freezestat circuit; used in Option G39 and G40 prior to 7/ ir Flow Proving Switch (Opt W1) 23 - Venter Pressure Switch 27 - Firestat (Opts 2, 3) 22 - Ignition ontroller 15 - Fan Time elay Relay Location of 32 - Signal onditioner (Opt G21); 39 - mplifier (Opt G7,8,9); or 29 - uctstat (Opt G3) 20, 21 - Limit ontrol 41 & 42 - Low Gas Pressure Switch (Opt P4) 43 - High Gas Pressure Switch (Opt P4) 14 - Venter Time elay Relay Limit ontrol and Limit Shield for S Series 6 ode 20 - Limit ontrol 50417, opens 125 F; closes 105 F Limit ontrol and Limit Shield for SE Series 6 ode 20 - Limit ontrol 50418, opens 145 F; closes 125 F ode 20 - Limit ontrol Shield, 9704 ode 21 - Limit ontrols used on Model SSL mfgd beginning 1/97 (for older units, see below) utomatic Reset Limit ontrol with Linear Sensor, TO #10HG11, ode 21 - Limit ontrols and Shields used on Model Series SSL mfgd prior to 1/97 Limit Shields utomatic Reset Limit ontrol, TO #60T11 Form P-S (03-18) PN269822R13, Page 4 utomatic Reset Limit ontrol, TO #60T11 ode 20 - Limit ontrol Shield, 9704 Key: (pplies to both limit tables) "L" lower abinet ir Flow Furnace #1 Furnace #2 Furnace #3 Furnace Size 400 Sizes 500/600/800 Sizes 1050/1200 # , 145 F , TO #10HG , 145 F 50417, 125 F # , 170 F , TO #10HG , 145 F # , 170 F , TO #10HG11 Furnace Size 400 Sizes 500/600/800 Sizes 1050/1200 # , 145 F 50418, 145 F 12229, Limit Shield 12229, Limit Shield 50417, 125 F # , 170 F 19080, 155 F 9704, Limit Shield # , 170 F

5 ode 22 - Ignition ontrollers Ignition ontroller for Intermittent Spark Pilot System without Lockout, (Serial No. ode 94) To replace a previously used recycling ignition controllers without lockout (Serial No. odes 62 and 66), order Replacement Kit, Ignition ontroller for Intermittent Spark Pilot System with Lockout, (Serial No. ode 95) To replace a previously used ignition controllers with lockout (Serial No. odes 63, 65 and 84), order Replacement Kit, ode 24 - EO evice, Micro #G5P0201, (Use on Series 6 units manufactured prior to 12/99) Mounting Plate, odes 25 - lower ir Flow Switch, Tridelta FP6605, Normally Open Non-adjustable, Setpoint.175" w.c., See page 26 for blower sensor probe. (ir Proving Switch, Option W1) ode 23 - ombustion ir Pressure Switch For units mfgd beginning 7/04 (except S Series models with Option G 39, 40, 41, or 42 gas controls) for altitudes to 4000 ft, setpoint 0.58 ±.05"w.c.; for altitudes above 4000 ft, , setpoint 0.52 ±.05" w.c. For S/SE units mfgd beginning 7/04 with Option G39 or 40 and 1st furnace of SSL with Opt G41 or 42 gas controls, for Sizes or PN for S/ SE Sizes and SSL For units mfgd between 12/91 and 7/04 (except S Series Models with Option G39/40/41/42 gas controls), for altitudes to 4000 ft, order replacement kit ; for altitudes above 4000 ft, For S/SE units mfgd between 12/91 and 7/04 with Option G39 or 40 and 1st furnace of SSL with Opt G41 or 42 gas controls, for Sizes or PN for S/SE Sizes and SSL ode 26 - Summer/ Winter Switch (Used in Options F4 and H1) (6 mp) - SE (10 mp) - SE ode 27 - Firestat, Honeywell #L4029E 1029, Manual reset opens at 200 F, Firestat Gasket, (used when firestat is used w/o cover) Firestat Shield, (discharge firestat only) ode 28 - Freezestat, J/ #I9F- 12, o F, , (replaces 16108) ulb lamp, Grommet lamp, able lamp, ode 28 - Two-Stage uctstat, Honeywell T , F, apillary Length 5' - Used in Gas ontrol Options G3, G4, and G5 ulb Holder, able Strap, ischarge Sensor Location - one of the locations below. Retaining Plate, 7727 (Entrance into the ductwork) Gasket, 7726 apillary Tube Element racket shown is used with Essex uctstat Honeywell ductstat uses bracket, abinet Leg Model S uct Furnace Front (ischarge) View uctstat ulb in Option G3 ode 30 - Remote uctstat Modules Used in Gas ontrol Options G15, G16, G17, G18, G19, G20 ode 30 - uctstat Sensor and Holder for ode 30 Remote uctstats = uctstat Temperature Selector Module, J/ 350-1, = Stage dder Module, J/ S350-1, = igital Temperature isplay Module, J/ 350-1, uctstat Sensor Holder, #TE6001-1, uctstat Sensor only, #99-25, , (part of below) Form P-S (03-18) PN269822R13, Page 5

6 Electrical omponents (cont'd) ode 31 - ischarge Sensor for Modulating Gas ontrol Options 48041, Maxitrol TS-121, for Options G8 and G , Maxitrol TS-194, for Option G39 and G41 Gasket, ode , Signal onditioner for Modulating Gas ontrol Options G21 and G40 odes 33 and 34 - Fuse and Fuseholder Fuse Holder, Fuses: 8 mp, mp, mp, ode 35 - onvenience Outlet Receptacle (Option 2), ode 36 - Motor ontactor, 24V oil, (replaces & on SSL) (replaces & on SE) For blower motor starters, see pages and ode 37 - Temperature ontrol, J/ #19-24, F, used in Gas ontrol Option G41 and G42 on Model SSL, ode 38 - Reverse Flow Limit, #60T , racket, ode 39 - mplifiers for Modulating Gas ontrol Options Kit replaces 1010 mplifier, 48035, used in Maxitrol 21HR (Option G9) and 20H (Option G7) Systems and 1011F mplifier, 48036, in Maxitrol 30H (Option G7) and 31HR (Option G9) Systems , Maxitrol 1092, used in Option G39, G40, G41, and G42 mplifier, Maxitrol 1010U, , in Replacement Kit Kit replaces 1010F mplifier, 48037, used in Maxitrol 21H (Option G8) Systems and 1011F mplifier, 48038, used in Maxitrol 31H (Option G8) Systems mplifier, Maxitrol 1010U, , in Replacement Kit ode 40 - Remote Temperature Selectors for Modulating Gas ontrol Options 48042, , Maxitrol Maxitrol T121, T , used in used in Opt G9 Options G 39, 40, 41, 42 odes 41, 42, 43 - Gas Pressure Switches odes 41 & 42 - Low Gas Pressure Switch, Natural Gas (Range 1-6" w.c.); Propane (Range 6-24" w.c.) utomatic Reset, Settings - 50% of minimum inlet gas pressure as stated on the unit rating plate ode 43 - High Gas Pressure Switch, Manual Reset, Settings - 125% of normal manifold gas pressure as stated on the unit rating plate Vent Limiter, Maxitrol 1209, ode 45-2-Speed Motor Speed Selector Relay, Essex , 24V, Form P-S (03-18) PN269822R13, Page 6 racket, ode 44 - Gas Pressure Switches used in Gas ontrol Options G39, G40, G41, G42 Primary Gas Flow Pressure Switch, White Label, 1.1 w.c., For G 39, 40, 41, 42 with a solenoid actuator (mfgd before 11/03), ackup Gas Flow Pressure Switch, Yellow Label 1.4 w.c., For G 39, 40, 41, 42 with a gear motor (mfgd beginning 11/03), there are two gas flow pressure switches with the white label, 1.1 w.c., arryover Regulator odes 46 - ontrol and amper Transformers, 200 & 300 V Modulating Valve Single-Stage Gas Valve NOTE: arryover regulator is on page 11. See Parts Form P-VLVES for gas valves , 575/115/300V - Use on 115V furnace 39095, 230/460/ V 39094, 208/24/200V

7 ode 47 - irty Filter Pressure Switch, Tridelta P4434, Field adjustable; range.17 to 5.0" ±.05" w.c. ode 48 - KV Transformer * Special order Primary KV 220/ / / * * * * * * 24392* 14996* * 26628* 14997* * 26630* 14998* * 26631* 15003* ode 50 - Toggle Switches 40277, PT, 3-Position Toggle Switch in a 4x4 box (Same as Option N1) 39733, SPT,2- Position Toggle Switch in a 2x4 box (Same as Option N3) 39732, PST, 2-Position Toggle Switch in a 2x4 box (Same as Option N2) , PT, 3-Position Toggle Switch (replaces 21826) - Used in Option N1 and Remote onsole Options R 5, 6, 7, 8, 10, 11, and , PST, 2-Position Toggle Switch (replaces 1052) - Used in Options N3, N4, and Remote onsole Options R 3, 4, 7, 8, & , PST, 2-Position Toggle Switch (replaces 16816) - Used in Options N2, G3, G8, G9 and Remote onsole Option R , SPST, 2-Position Toggle Switch in a 2x4 box (Same as Option N4) NOTE: When replacing SPST switch with SPT switch, make wiring connections at appropriate two terminals for switch to function properly. ode 51 - isconnect Switches escription 's - U.S. 's - anada Indoor Same as Opt Indoor Same as Opt 30 mp 240V Non-Fusible P1 30 mp 240V Fusible (less fuses) P2 30 mp 600V Non-Fusible P P58 30 mp 600V Fusible (less fuses) P P41 60 mp 240V Non-Fusible P21 60 mp 240V Fusible (less fuses) P17 60 mp 600V Non-Fusible P P60 60 mp 600V Fusible (less fuses) P P mp 240V Non-Fusible P mp 240V Fusible (less fuses) P mp 600V Non-Fusible P P mp 600V Fusible (less fuses) P P45 ode 52 - Thermostats (Wall mounted Option L; or mounted on the remote console, Opt RT, see ode 57) 1-Stg Heat/ool, 2-Stg Heat/ool, 24v Electronic modulating 1-Stg Heat/ool, 24v Electronic, 24v 24v snap acting digital thermostat (40- room override (60- programmable thermostat programmable thermostat (50-90 F) 90 F) with fan auto-on 85 F), low voltage for (45-88 F) with fan auto-on thermostat, 2-stg heat with fan auto-on & function makeup air and cool/off/heat. and/or cooling cool-off-heat switches (same as L1 & RT1) (same as L22 & RT2) (same as L9) (same as L52 & RT9) (same as L33 & RT5) Optional Remote onsole Optional R style remote console includes a mounting 55 ring so that the console may be either recessed or wall 56 mounted. The box is of 16 gauge steel with knockout 54 holes for field wiring. The cover is made of plastic with custom engraving. Order replacement parts for Option R remote console by. ode escription 53 Remote onsole ox /16x6-5/8x2-5/ Remote onsole ox /16x6-5/8x2-5/ Mounting Ring for 10-1/16" long box Mounting Ring for 15-1/16" long box Light for Red Lens, Solico #5T1L-R SPT Switch, utler Hammer #7505K PT Switch, utler Hammer #7561K Single-Stage Heating Thermostat Two-Stage Heating Thermostat Single-Stage Heating/ooling Thermostat Two-Stage Heating/ooling Thermostat Potentiometer (See OE 371, page 28) Form P-S (03-18) PN269822R13, Page 7

8 Remote onsole (cont'd) ode 53 - onsole ox 1-5/16 (33mm) 2-3/8 (60mm) 6 (152mm) 5-15/32 (139mm) Knockout Hole Locations (measured from centerlines) 2-1/8 (54mm) 2-3/8 (60mm) 2-1/8 (54mm) Remote onsole omponents by Option - Options R1-R12 omponent Function In Opt R ode lower ON Light Lights when blower is operating urner ON Light Lights when burners are lit irty Filter Light Lights when the pressure switch indicates that filters 2, 4, 6, 8, need to be cleaned or replaced ON position energizes the unit for thermostat control. On/Off ontrol 3, 4, 7, 8, OFF position de-energizes the unit and closes Switch 11, 12 optional automatically controlled outside air dampers. 56 Summer/Winter/Off ontrol Switch Heat/Vent/ool ontrol Switch Summer position energizes the blower only. "Winter" position energizes the unit for thermostat control. "Off" position de-energizes the unit and closes optional automatically controlled outside air dampers. Heat position energizes the unit for thermostat control. Vent position energizes the blower & opens automatically controlled outside air dampers. "ool" position energizes blower, dampers, and cooling unit. 5, 6, , 8, 11, ooling Light Lights when cooling system is operating 7, 9, 11, onsole imensions (wall mounted - not recessed) onsole Options Optional ontrol Length* Height* epth R 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12 without 10-3/4" 7-5/8" 2-5/8" R 1, 2, 3, 4, 5, 6, 9 with 10-3/4" 7-5/8" 2-5/8" R 7, 8, 10, 12 with 15-3/4" 7-5/8" 2-5/8" R 11 with & without 15-3/4" 7-5/8" 2-5/8" * Subtract 5/8" from length & 1" from height when recessing console (not using wall-mounting ring) ode 60 - Illinois School ode - Special Manifold Option M12 includes a Remote onsole with larm ell and Silencing uttons 60 - onsole ox, Light, Switch, larm ell, Venter and Flue uct Parts - ll Models Venter Motor and Wheel - ll Furnaces Venter Motor and Wheel ssembly.305 (.77cm) Flue uct and Venter Parts for all S/SE units that do not have % electronic modulation Option G 39 or 40; all furnaces in an SSL unit without Option G 41 or 42; and 2nd and 3rd furnaces in an SSL unit with Option G41 or G (gasket for Flue uct over, ode 79 - not shown) Venter Motor and Wheel - see odes Flue uct and Venter Parts for single furnace with % electronic modulation Option G39 or G40 and the first furnace in multiple furnace units with Option G41 or G Venter Motor and Wheel - see odes Form P-S (03-18) PN269822R13, Page 8

9 ode escription SSL / /800/1200 S, SE V, K (replaces ) Venter Motor and 208/230V, K2,3,5, (replaces ) apacitor 460V, K 7, (replaces ) 71 Venter Motor Mounting Plate ssembly (includes plate, , and (includes plate (includes plate and support ring) support ring, ) & support ring ) 72 Nuts (Keps) (4) Venter Wheel, Flue uct with Sensing Tube w/aluminized heat Venter Restrictor exchanger Plate w/stainless steel heat exchanger 76 Venter Gasket Venter Housing Flue uct over Plate Gasket Flue uct over Plate (not illustrated) Flue uct Restrictor and For S/SE with 80 Gear Motor Option G 39 or 40, (includes 80,, and 1st furnace of, ) SSL with G End Switch (2) (2) or 42 mfgd beginning 80 Gear Motor / Gear Mtr apacitor Time elay Relay Venter Gasket or Venter Restrictor Plate (Sizes ) 83 or Inlet Ring (Sizes 300 & 400) Venter Housing ssembly Replacement Gear Motor Kit (to replace solenoid actuator) Replacement Solenoid ctuator only (select by voltage - same apply to Sizes 400/800/1200) For S/SE with Option G 39 or 40, and SSL with G 41 or 42 mfgd before 11/ (replaces (460V)) (replaces (208/230V)) (replaces (115V)) (replaces ) (replaces ) (replaces ) Interior abinet Parts and Heat Exchanger - ll Models ode Heat Exchanger (non-control side) ode escription SSL 500/ / /800 /1200 S/SE / / / urner Rack ack race Rear Seal Plate Outlet uct Gasket (2) Flue ollection ox ssembly Side Gasket (2) Front and Rear Gasket (2) Heat Exchanger - pplies to all Models (one heat exchanger per furnace section; directional baffles apply as listed) Heat Exchanger irectional ir affles (page 10) irectional air baffles cannot be installed in the replacement heat exchanger at the factory. They must be ordered separately and installed in the field. 1) Model S is equipped with a heat exchanger directional air baffle assembly (ode 102) as illustrated on page 10. When replacing a heat exchanger, check to see if the baffle assembly can be salvaged. If the baffle assembly cannot be salvaged, order and install a replacement. 2) Model HS and the discharge furnace only on a Model SSL are equipped with only a rear top baffle support (ode 103) and a rear top baffle (ode 104). If these parts cannot be salvaged, order and install replacements. Form P-S (03-18) PN269822R13, Page 9

10 Heat Exchanger (cont'd) ode Heat Exchanger 105 ode Heat Exchanger affle ssy ttaches with screws Heat Exchanger affle in Model HS and Model SSL discharge furnace only E 102F irflow Screws 104 irflow Screws ode escription 100 Heat Exchanger for S, SE, SSL (replacement gaskets, ode 101, required) SSL Qty 500/ / /800/1200 S, SE / / / luminized Steel Stainless Steel Heat Exchanger Gaskets for S, SE, and SSL (required w/replacement heat exchanger) Heat Exchanger affle ssembly Finger affle Support racket > (2) (2) (2) (2) (4) (4) (4) 102 Finger affle > (3) (4) (6) (8) (11) (13) (15) 102 ottom affle Support Rear Top affle Support E Rear Top affle F Side Finger affle Rear Top affle Support ll HS & SSL Rear Top affle discharge unit only Heat Exchanger Tube affles ("V" with Turbulators) (4) (5) (7) (9) (12) (14) (16) 106 urner Rack Slide Rail urner Rack and omponents - pplies to all Furnaces (one per furnace section) ode urner Rack ode Manifold ode urner Orifices Series 6 Natural Gas urner Rack with two flash carryovers (one on each end) Gas Valve - See Form P-VLVES Series 6 Propane Gas urner Rack with air shutters and a regulated carryover with carryover tube and drip shield. (has a flash carryover on the end opposite the orifices) ode 123 Gas Valve - See Form P-VLVES ode urner Orifices (sea level) SSL / 400/ /1200 S/SE Qty Natural Gas rill #41 #42 #44 #42 #43 #42 #44 #42 #42 # Propane rill MM MM # MM # #55 MM MM MM MM Form P-S (03-18) PN269822R13, Page 10 odes 117 and arryover Tube and rip Shield for urner Rack

11 ode 110 escription urner Rack with luminized Steel urners for natural gas (includes main burners, two flash carryovers, aeration panel, burner rack skirt and auxiliary sensing probe) urner Rack with Stainless Steel urners for natural gas (includes main burners, two flash carryovers, aeration panel, burner rack skirt, and auxiliary sensing probe) urner Rack with luminized Steel urners for propane gas (includes main burners, one flash carryover, aeration panel, regulated carryover lighter tube, air shutters, burner rack skirt, and auxiliary sensing probe) urner Rack with Stainless Steel urners for propane gas (includes main burners, one flash carryover, aeration panel, regulated carryover lighter tube, air shutters, burner rack skirt, and auxiliary sensing probe) Replacement burner rack for Models S, SE, SSL with % modulation with Option G39 or G40 or 1st furnace of Model SSL with Option G41 or G42, natural gas only, is the same stainless steel burner rack as used with propane gas. SSL S, S, S, SE, SSL Series 6 (If unit has Gas ontrol Option G39, G40, G41, or G42 see below) S, SE, SSL with Opt G 39 or 40 and 1st furnace of SSL with Option G41 or G42 S/SE / / / / / / 800/ Qty (4) (5) (7) (9) (12) (14) (16) 111 Main urner Tube only luminized Stainless Steel Flash arryover (one piece) Series 6 natural gas have 2 per burner rack; Series 6 propane & all Series 3 & 5 have 1 per burner rack Flash arryover Right Section Flash arryover Left Section Flash arryover enter Section arryover Lighter Tube (Tube only) Series 6 Propane only 118 arryover Lighter Tube rip Shield arryover Orifice (NOTE: Series 6 Natural Gas does not have a carryover lighter tube except for heaters with % modulation, Options G 39, 40, 41, or 42) Propane - all Natural Gas with/opt G 39 or 40 or 1st furnace of SSL with Opt G 41 or rill (70) (65) (59) (57) rill (70) (65) (59) (56) 120 urner Rack Isinglass (2) Manifold (less orifices) urner Orifices -- see chart on bottom of page 10. Regulated arryover & ir Shutters - Propane urner odes ode escription ll Sizes ir Shutter Regulated arryover ssembly - Propane (includes odes 123-K) Hardware for arryover Regulator, Maxitrol RV-12, Propane urner Propane Gas Rack arryover Regulator Tubing 1/4x5-1/2" arryover Regulator Tubing 1/4x1-1/4" arryover Regulator Tag arryover Regulator Fitting (ompression 123E Fitting) 9664 arryover Regulator Fitting, Regulator to 123F Manifold 1436 arryover Regulator Fitting, 90 rass (2) 123G Elbow ir Shutter djustment Screw, 1/4-20 x /2" long ir Shutter Screw Nut, 1/4" ir Shutter Slide Tinnerman Nut, 1/4" (not illustrated) 124 ir Shutter djustment Instruction Tag Pilot Shutoff all Valve Valve, dapter ode arryover Regulator ssembly 3284 for all Propane urner Racks (not in 123G ode 123) F 123E 123 ode arryover Regulator used with Modulation Gas ontrol Options G39 or G40 or 1st furnace of SSL with Options G41 or 42, See illustration in ode 44 on page ode Manual Gas Valves - ll Furnaces (Reference: For electric gas valves, see Form P-VLVES. Electric gas valves are identified from the heater Serial No.; see page 2.) 1", ; 1-1/4", ; 1/2", ; 3/4", luminum Shutoff Valves 1/2", , with Union, 15971; 3/4", , with Union, PSIG Gas Valve 1", ; 1-1/4", Form P-S (03-18) PN269822R13, Page 11

12 ode Pilots Vertical Spark Pilot for Models S, S, S, SE Series 6 and SSL Replacement Pilot Kits Natural Gas Propane ode omponent escription Natural Gas Pilot ssembly with orifice, pilot tubing, flame probe; less flame sensor lead and fitting (J/ J981HKW ) Propane Pilot ssembly with orifice, pilot tubing, flame probe; less flame sensor lead and fitting (J/ J981HKW ) Natural Gas Orifice only, # (brass) Propane Orifice only, # (black) Pilot Tubing, 1/8" O x 18" lg (J/ # ) ompression Fitting FTG75 (2 required when replacing pilot tubing) Flame probe, J/ Y uxiliary flame probe with bracket, J/ Y75 G (2) Sensor lead assembly, 18 ga. x 14", 150 Horizontal Spark Pilot - Models S, S, S, SE, SSL prior to Series 6 Replacement Pilot Kits: Natural Gas Propane * 6* 1N,1P 2N, 2P 4 3 ode omponent escription 1N Natural gas pilot with orifice, high tension lead, flame probe (less pilot tubing & sensor lead) 1P Propane pilot with orifice, high tension lead, flame probe (less pilot tubing & sensor lead) 2N Natural gas pilot orifice only (7221) 2P Propane pilot orifice only (4209) Pilot tubing, 22" long 9664 Nut with breakaway ferrules (2 required) Sensor lead 9" long 5* rimp-on, 90 Rajah terminal connector 6* oot Terminal Protector Instructions for connecting ignitor lead on replacement spark pilots to Model G60 & G67 ignition controllers: 1. Identify the ignitor wire attached to the pilot electrode. Slip the 90 protective boot on to the wire, as illustrated. 2. On the "open" leg of the 90 crimp-on terminal ( ), locate a flat, triangular spike tab punched in the metal. With the tip of a small, straight screwdriver, force the spike tab toward the inside of the connector. Straighten the tab to a vertical position. 3. Insert the ignitor wire into that same connector leg (just to the 90 bend) and push the wire onto the protruding spike tab, making sure that the tab penetrates the insulation. (o not strip the ignitor wire.) Using a crimping tool or pliers, squeeze the sides of the terminal to form a "" shape. The ignitor wire should now be firmly held by the terminal. 4. Slide the protective boot over the terminal. Holding the boot, attach the 90 Rajah terminal to the ignitor lead Rajah connector on the Model G60 or G67G/NG-2 ignition controller. rimp-on, 90 Rajah Terminal onnector, Protective oot, Effective with replacement pilots purchased beginning 9/91, the crimp-on connector and protective boot are required (in the kit or separately) on units equipped with a Model G60 or G67G-NG-2 ignition controller. (NOTE: These parts are not required when the ignition controller is a Model G67G-5 or G770NG-4.) Install boot and terminal on ignitor wire. Step 4) ttach to Ignition ontroller Step 2 & 3) ttach 90, rimp-on Terminal Step 1) Slip oot over End of Wire Special Manifold omponents odes Illinois School ode, Option M12 (applies to Model SE Series 6 and Model SSL) ode escription omponents for Illinois School ode Manifold (Option M12 is no longer required but was available on SE and SSL 130 Low Gas Pressure Switch, see page 6, ode 41 or High Gas Pressure Switch, see page 6, ode Vent Limiter, Maxitrol 1209, see page Pressure Switch rackets (3-7) Manual Gas Valve (one per unit), page Manual Pilot Shutoff (one per unit), page Safety Solenoid Valve (one per unit) Pilot Valve (one per unit) Pilot Valve racket Relay SPT - Order Replacement Kit, Relay SPST - Order Replacement Kit, Pilot Regulator, Maxitrol 400S Switch Push utton (larm Silencing) larm ell (daptable Edwards # , 24V) Pilot High Pressure (Natural 12 w.c. minimum; Propane 15 w.c. minimum) 136 Main urner Low Pressure (Natural 5 w.c. minimum; Propane 11 w.c. minimum) To pilot Redundant Valve (Pilot port is plugged) 135 Safety Valve 140 Main urner High Pressure (Natural Gas 4 w.c. minimum; Propane 9 w.c. minimum) Key: NO = Normally Open N = Normally losed Incoming Gas Manual Shutoff Valve Form P-S (03-18) PN269822R13, Page 12

13 odes IRI, Option M13 (applies to Model SSL 1050 and 1200) - ISONTINUE 9/2003 ode escription ode escription omponents for IRI Manifold (Option M13) 144 Fluid Power Valve (2)89356 Transformer 230/460 to 115V,.5KV Fluid Power Valve ctuator (2)86993 Transformer 208 to 115V,.5KV Low Gas Pressure Switch, pg 6, ode 41 or 42. Transformer 208 to 115V, 250V High Gas Pressure Switch, page 6, ode 43. Transformer 230/460/575 to 115V, 300V Vent Limiter, Maxitrol 1209, pg 6 (2) Pilot Regulator (3) Vent Solenoid Valve Valve ox Top Pilot Valve (one per unit) Valve ox Inlet Side Manual Shutoff & all Valve dapter, page Valve ox Plain Side Pilot Manual Shutoff (1 per unit), page Valve ox ack RM Relay - Order Replacement Kit, Top oor Pilot Valve racket (2) ottom oor ode escription omponents for FM Manifold (Option M14 is available on Model SSL) 162 Fluid Power Valve Fluid Power Valve ctuator Manual Shutoff and all Valve dapter, page Pilot Manual Shutoff (one per unit), page Pilot Valve (one per furnace) Pilot Valve racket Pilot Regulator Transformer 230/460/575 to 115V, 300V Transformer 208 to 115V, 250V Valve ox Top Valve ox Inlet Side Valve ox Plain Side Valve ox ack Top oor ottom oor odes 144 and ctuator (M/H V ) Valve only (used with actuator on the right) Size Gas M/H 1" N or P V /4" N or P V " N or P V odes FM, Option M14 (applies to Model Series SSL) ranch Tee, ode Vent Valve, G/ #S262, ode 138, 153, Pilot Valve racket in Options M12, M13, M14, Settings Natural 4 Propane Vent Pipe ranch Tee, ranch Tee, odes 136, 137, 149, Solenoid Valve 1/4", /4", ", odes 155 and Pilot Regulator, Maxitrol R400S, Springs for R400S Pilot Regulator Maxitrol # olor Pressure Range pprox Length. R rown 1.0 to 3.5" w.c. 1-9/16 to 2" R admium Plate 2.0 to 5.0" w.c. 1-9/16 to 2" R admium Plate 3.0 to 6.0" w.c. 1-9/16 to 2" R Pink 3.0 to 8.0" w.c. 1-9/16 to 2" Replacement lower Motors, Starters, and Variable Frequency rives - EFORE PRIL 1, 2013 Replacement Motors (Tables on pages 14-16) Variable Motors in the Open, TEF, and Premium Efficiency tables Frequency rive that are highlighted in gray do not have internal overload protection and must be used with the motor starter and (Option VF) and overload listed in the table. Refer to the wiring diagram for Matching Line applicable L and N or VF option codes. Reactor See ode 36, page 6, for standard motor contactor (Option N2), (for SSL) & (for SE), for motors with internal overloads. If equipped with an optional variable frequency drive, see 's on the right. Replacement IE Starters and Overloads (Listed by motor on pages ) When ordering a replacement IE starter (contactor) or overload, check the manufacturer's IE Starter (ontactor) IE djustable Overload number on both parts. If the number is different than that listed, both components must be replaced. IE Starter (contactor) and overload are mounted on rail, Replacement holding coils are listed on page 17. If the motor has a NEM starter, see replacement information on page 16. Mtr HP VF rive & Matching Line Reactor 208/1/60 230/1/60 208/3/60 230/3/60 480/3/60 575/3/60 OP TEF OP TEF Prem OP TEF Prem OP TEF Prem 1/2 rive N/ N/ Line Reactor N/ 3/4 rive N/ N/ N/ Line Reactor N/ 1 rive N/ Line Reactor /2 rive N/ Line Reactor rive Line Reactor N (uilt-in) rive Line Reactor N (uilt-in) rive N/ Line Reactor N (uilt-in) Form P-S (03-18) PN269822R13, Page 13

14 Replacement lower Motors and Starters - EFORE PRIL 1, 2013 (Line Voltage oils) Open Motor Frame Service Power Starter (N10) Starter Overload Type HP L Mfr's #. fla volt ph Size Factor Factor Mfr # Mfr # min max F / L00310T-J RT1-L F / L00310T-L RT1-J Open 1/4 2 F / L00310T-S RT1-J M K L00310T-L RT1-G M K L00310T-S RT1-G M K L00310T-U RT1-F F / L00310T-J RT1-L F / L00310T-L RT1-K Open 1/3 3 F / L00310T-S RT1-K M K L00310T-L RT1-G M K L00310T-S RT1-H M K L00310T-U RT1-F F Z 1.15 L00310T-J RT1-N F Z 1.15 L00310T-L RT1-L F Z 1.15 L00310T-S RT1-L Open 1/2 4 H L L00310T-L RT1-J H L L00310T-S RT1-K H L L00310T-U RT1-H H H L00310T RT1-F V L01310T-J RT1-P V L00310T-L RT1-M V L00310T-S RT1-L Open 3/ P L00310T-L RT1-K P L00310T-S RT1-K P L00310T-U RT1-G H H L00310T RT1-F H L01310T-J RT1-P H L00310T-L RT1-M H L00310T-S RT1-M Open 1 6 H H L00310T-L RT1-K H H L00310T-S RT1-K H H L00310T-U RT1-H E1006L N143T 1.15 L00310T-Y RT1-G L02310T-J RT1-P L00310T-L RT1-M L00310T-S RT1-M Open H884L F L00310T-L RT1-L H884L F L00310T-S RT1-L H884L F L00310T-U RT1-K E R145T L00310T-Y RT1-H R1204V H L25310T-J RT1-T R1204V H L01310T-L RT1-N R1204V H L01310T-S RT1-N Open 2 8 H HZ L00310T-L RT1-M H HZ L00310T-S RT1-M H HZ L00310T-U RT1-K E P145T L00310T-Y RT1-J L L02310T-L RT1-P L L01310T-S RT1-P Open 3 9 H P56HZ 1.15 L00310T-L RT1-N H P56HZ 1.15 L00310T-S RT1-N H P56HZ 1.15 L00310T-U RT1-L H P145T L00310T-Y RT1-K V L184T L04310M-L RT1-V V L184T L04310M-S RT1-V Open J Y56HZ L01310T-L RT1-P J Y56HZ L01310T-S RT1-P J Y56HZ L00310T-U RT1-M H Y56HZ L00310T-Y RT1-L V S215T L06311M-L RT2-E V S215T L45310M-S RT1-V Open M3311T T L25310T-L RT1-U M3311T T L25310T-S RT1-T M3311T T L01310T-U RT1-N M3311T T L00310T-Y RT1-M V S215T L06311M-L RT2-E Open V S215T L06311M-S RT2-E M3313T T L04310M-L RT1-V M3313T T L04310M-S RT1-V Open M3313T T L01310T-U RT1-P M3313T T L01310T-Y RT1-P Form P-S (03-18) PN269822R13, Page 14

15 Replacement lower Motors and Starters - EFORE PRIL 1, (ont'd) (Line Voltage oils) Open Motor (cont'd) Frame Service Power Starter (N10) Starter Overload Type HP L Mfr's #. fla volt ph Size Factor Factor Mfr # Mfr # min max FM2513T T L06311M-L RT2-G Open EHFM2523T T L06311M-S RT2-E EHFM2523T T L25310T-U RT1-T FM2513T T L02310T-Y RT1-S FM2515T T L07311M-L RT2-H Open FM2515T T L07311M-S RT2-G FM2515T T L04310M-U RT1-V FM2515T T L25310T-Y RT1-T TEF Motor Frame Service Power Starter (N10) Starter Overload Type HP L Mfr's #. fla volt ph Size Factor Factor Mfr # Mfr # min max # M48 1 L00310T-J RT1-K H L00310T-L RT1-J TEF 1/ H L00310T-S RT1-H L00310T-L RT1-H L00310T-S RT1-G L00310T-U RT1-F #906L N L00310T-J RT1-L N L00310T-L RT1-J TEF 1/ N L00310T-S RT1-J H L L00310T-L RT1-G H L L00310T-S RT1-G H L L00310T-U RT J L00310T-J RT1-M J L00310T-L RT1-K J L00310T-S RT1-K TEF 1/2 21 H H L00310T-L RT1-J H H L00310T-S RT1-J H H L00310T-U RT1-F H J L00310T-Y RT1-F F F L01310T-J RT1-P F F L00310T-L RT1-L F F L00310T-S RT1-L TEF 3/4 22 H K L00310T-L RT1-J H K L00310T-S RT1-J H K L00310T-U RT1-G H L L00310T-Y RT1-F L L01310T-J RT1-P L L00310T-S RT1-M L L00310T-S RT1-M TEF 1 23 H J L00310T-L RT1-K H J L00310T-S RT1-K H J L00310T-U RT1-H H H L00310T-Y RT1-G TK56H L02310T-J RT1-S TK56H L00310T-L RT1-N TK56H L00310T-S RT1-N TEF H L56H L00310T-L RT1-L H L56H L00310T-S RT1-L H L56H L00310T-U RT1-J E M145T L00310T-Y RT1-H F182T L04310M-J RT1-U L3516TM HZ L01310T-S RT1-P TEF 2 25 M3587T T L00310T-L RT1-M M3587T T L00310T-S RT1-L M3587T T L00310T-U RT1-K M3587T T L00310T-Y RT1-J K F184T 1 88 L04310M-J RT1-V K F184T 1 88 L02310T-S RT1-P TEF 3 26 M3559T T 1.15 L00310T-L RT1-M M3559T T 1.15 L00310T-S RT1-M M3559T T 1.15 L00310T-U RT1-K M3660T T 1.15 L00310T-Y RT1-K K F184T L04310M-S RT1-T M3663T T 1.15 L01310T-L RT1-S TEF 5 27 M3663T T 1.15 L01310T-S RT1-P M3663T T 1.15 L00310T-U RT1-L M3663T T L00310T-Y RT1-L K F215T L45310M-S RT1-W TEF T T L04310M-L RT1-U T T L25310T-S RT1-T TEF T T L01310T-U RT1-N M3710T T L00310T-Y RT1-M Form P-S (03-18) PN269822R13, Page 15

16 Replacement lower Motors and Starters - EFORE PRIL 1, (ont'd) (Line Voltage oils) TEF Motor (cont'd) Frame Service Power Starter (N10) Starter Overload Type HP L Mfr's #. fla volt ph Size Factor Factor Mfr # Mfr # min max K T L06311M-S RT2-E M3774T T L04310M-L RT1-V TEF M3774T T L04310M-S RT1-U M3774T T L01310T-U RT1-P M3774T T L01310T-Y RT1-N E301M T L06311M-S RT2-E E301M T L25310T-U RT1-T TEF FM T L02310T-Y RT1-P FM2334T T L07311M-S RT2-G FM2334T T L04310M-U RT1-V FM2334T T L25310T-Y RT1-T Premium Efficient Motor Frame Service Power Starter (N10) Starter Overload Type HP L Mfr's #. fla volt ph Size Factor Factor Mfr # Mfr # min max HP T L00310T-L RT1-K EE 1 36 HP T 1.15 L00310T-S RT1-K HP T 1.15 L00310T-U RT1-G E N143T 1.15 L00310T-Y RT1-G E P145T L00310T-L RT1-L EE E T 1.15 L00310T-S RT1-K E T 1.15 L00310T-U RT1-J E R145T L00310T-Y RT1-H E P145T L00310T-L RT1-L EE 2 38 E T 1.15 L00310T-S RT1-L E T 1.15 L00310T-U RT1-K E P145T L00310T-Y RT1-J L405S489G T 1.15 L00310T-L RT1-N EE 3 39 EM3158T T L00310T-S RT1-M EM3158T T L00310T-U RT1-K L405S709G T 1.15 L00310T-Y RT1-K E H182T L02310T-L RT1-P EE 5 40 E H182T L02310T-S RT1-P E H182T L00310T-U RT1-M M3613T T 1.15 L00310T-Y RT1-L E T L04310M-L RT1-U EE E T L25310T-S RT1-T E T L00310T-U RT1-N M3311T T L00310T-Y RT1-M EM3313T T L04310M-L RT1-V EE EM3313T T L04310M-S RT1-U EM3313T T L01310T-U RT1-P M3313T T L00310T-Y RT1-P EFM2513T T L06311M-L RT2-E EE EFM2513T T L06311M-S RT2-E EFM2513T T L25310T-U RT1-T EFM2513T T L02310T-Y RT1-P E452-F S256T L07311M-L RT2-H EE EFM2515T T L06311M-S RT2-G EFM2515T T L04310M-U RT1-U EFM2515T T L25310T-Y RT1-T Speed lower Motors Motor ata Maximum Mtr mp raw Motor (Volts - Phase) IE Starter Rated HP entury Frame 1800 RPM 1200 RPM Manufacturer's 1/.44 M124 M145T EG2SP-S17--I-H-O /.44 M124 M145T EG2SP-S17--I-H-O /.44 M109 M145T EG2SP-S17-E-G-F-O /.68 M125 N145T EG2SP-S17--K-I-O /.68 M125 N145T EG2SP-S17--K-I-O /.68 M104 N145T EG2SP-S17-E-H-G-O /.88 M220 S182T EG2SP-S17--L-K-O /.88 M220 S182T EG2SP-S17--L-I-O /.88 M207 S182T EG2SP-S17-E-I-H-O /1.3 M221 S184T EG2SP-S17--M-K-O /1.3 M221 S184T EG2SP-S17--M-K-O /1.3 M208 S184T EG2SP-S17-E-K-H-O /2.2 M320 S215T EG2SP-S17--O-M-O /2.2 M320 S215T EG2SP-S17--O-M-O /2.2 M305 S215T EG2SP-S17-E-L-K-O /3.3 M317 Y215T EG2SP-S17--O-N-O /3.3 M317 Y215T EG2SP-S17--O-N-O /3.3 M T EG2SP-S17-E-M-L-O /4.4 M421 S256T EG2SP-S17--P-O-O /4.4 M421 S256T EG2SP-S17--P-O-O /4.4 M413 S256T EG2SP-S17-E-N-L-O Form P-S (03-18) PN269822R13, Page 16

17 IE Two-Speed Starter Effective 9/91, IE two-speed starters are used. Prior to 9/91, units with 2-speed motors were equipped with NEM starters. If replacing a NEM starter with an IE starter, replace the complete starter. See terminal cross reference chart (right). Original box and cover may be used for replacement IE starter. Replacement Holding oils for IE Starters - EFORE PRIL 1, 2013 Voltage GE # For Use with Starters eginning with GE# 24 L L00; L01; L02; L L1-J L00; L01; L02; L L1-L L00; L01; L02; L L1-S L00; L01; L02; L L1-U L00; L01; L02; L25 Voltage GE # For Use with Starters eginning with GE# 575 L1-Y L00; L01; L02; L25 24 L L04; L L3-J L04; L L3-L L04; L L3-S L04; L45 Terminal ross- Reference hart for Replacement IE Starters NEM IE Starter Wire Terminals 2T1 High Speed F 6T3 E 4T2 2T1 Low Speed 6T3 4T2 Relay/Starter oil Terminals Voltage GE # For Use with Starters eginning with GE# 460 L3-U L04; L L3-Y L04; L L4-L L06; L07; L08; L L4-S L06; L07; L08; L L4-U L06; L07; L08; L09 Replacement lower Motors, Starters and Variable Frequency rives - FTER PRIL 1, 2013 lower Motor (singlespeed) - Motors are listed by type, HP, and voltage. Highlighted motors do not have internal overload protection and MUST be used with the motor starter and overloads listed in the table unless the unit is equipped with a variable frequency drive. Motors not highlighted will have either a contactor (OE 36), a starter Option N10, or will be equipped with a variable frequency drive (Reference table on the right). Variable Frequency rive ontrol (Opt VF) & Matching Line Reactor Replacement isplay, Model S-P-, IE Starter (ontactor) VF rive and 208/1/60 Mtr HP 208/3/60 230/3/60 480/3/60 575/3/60 Matching Line 230/1/60 & Type Reactor OP TEF OP TEF Prem OP TEF Prem OP/TEF/Prem 1/2 rive N/ Line Reactor N/ N/ 3/4 rive N/ N/ Line Reactor N/ N/ 1 rive Line Reactor N/ 1-1/2 rive N/ Line Reactor rive Line Reactor N (uilt-in) rive Line Reactor N (uilt-in) rive N/ Line Reactor N (uilt-in) IE Overload Replacement IE Starters & Overloads See s listed in motor charts.pages Required on highlighted motors; optional on others unless unit is equipped with a variable frequency drive. Open Motor Starter (N10) Starter Overload Type HP Option L Mfr's No. Frame Fla Shaft Volt ph Mfr's No. Min Max GE # Open 1/4 2, F / /2" L00310T RT1-L Open 1/4 2, F / /2" L00310T RT1-J Open 1/4 2, F / /2" L00310T RT1-J Open 1/4 2, H200 K /2" L00310T RT1-G Open 1/4 2, H200 K /2" L00310T RT1-G Open 1/4 2, H200 K /2" L00310T RT1-F Open 1/3 2, F /2" L00310T RT1-L Open 1/3 2, F /2" L00310T RT1-K Open 1/3 2, H260 K /2" L00310T RT1-G Open 1/3 2, H260 K /2" L00310T RT1-H Open 1/3 2, H260 K /2" L00310T RT1-F Open 1/2 4, F Z 8.8 5/8" L00310T RT1-N Open 1/2 4, F Z 5.1 5/8" L00310T RT1-L Open 1/2 4, F Z 4.4 5/8" L00310T RT1-L Open 1/2 4, H880 L /8" L00310T RT1-J Open 1/2 4, H880 L56 3 5/8" L00310T RT1-K Open 1/2 4, H880 L /8" L00310T RT1-H Open 1/ H991 H /8" L00310T RT1-F Open 3/4 4, P /8" L01310T RT1-P Open 3/4 4, P /8" L00310T RT1-M Open 3/4 4, P /8" L00310T RT1-L Open 3/4 4, P /8" L00310T RT1-K Open 3/4 4, P /8" L00310T RT1-K Form P-S (03-18) PN269822R13, Page 17

18 Replacement lower Motors and Starters - FTER PRIL 1, (ont'd) (24 Volt oils) Open Motor (cont'd) Starter (N10) Starter Overload Type HP Option L Mfr's No. Frame Fla Shaft Volt ph Mfr's No. Min Max GE # Open 3/4 4, P /8" L00310T RT1-G Open 3/4 4, H992 H56 1 5/8" L00310T RT1-F Open 1 6, H /8" L01310T RT1-P Open 1 6, H /8" L00310T RT1-M Open 1 6, H /8" L00310T RT1-M Open 1 6, OS H882L 56H 4.0 5/8" L00310T RT1-K Open 1 6, OS H882L 56H 3.7 5/8" L00310T RT1-K Open 1 6, OS H882L 56H 2.0 5/8" L00310T RT1-J Open 1 6, OS H959 J /8" L00310T RT1-G Open 1.5 6, /8" L01310T RT1-P Open 1.5 6, /8" L00310T RT1-M Open 1.5 6, /8" L00310T RT1-M Open 1.5 6, H884 U /8" L00310T RT1-L Open 1.5 6, H884 U56 5 5/8" L00310T RT1-L Open 1.5 6, H884 U /8" L00310T RT1-K Open 1.5 6, OS H960 L56H 2.0 7/8" L00310T RT1-J Open R /8" L04310M RT1-U Open R /8" L01310T RT1-P Open R /8" L01310T RT1-P Open H886 56HZ 7 7/8" L00310T RT1-M Open H886 56HZ 6.6 7/8" L00310T RT1-M Open H886 56HZ 3.5 7/8" L00310T RT1-K Open OS H965V1 L /8" L00310T RT1-J Open L /8" L01310T RT1-P Open L /8" L01310T RT1-P Open 3 9, H845 P56HZ 9 7/8" L00310T RT1-N Open 3 9, H845 P56HZ 8.6 7/8" L00310T RT1-N Open 3 9, H845 P56HZ 4.3 7/8" L00310T RT1-L Open 3 9, H954 N56HZ 3.6 7/8" L00310T RT1-K Open 5 9, aldor L1409T 184T /8" L04310M RT1-U Open 5 9, aldor L1409T 184T /8" L04310M RT1-U Open 5 9, Y56HZ /8" L01310T RT1-P Open 5 9, Y56HZ /8" L01310T RT1-P Open 5 9, Y56HZ 6.6 7/8" L00310T RT1-M Open 5 9, H956 Y56HZ 5.4 7/8" L00310T RT1-L Open OS-V305 S215T /8" L06311M RT2-E Open OS-V305 S215T /8" L06311M RT2-E Open WEST TP7/54 213T /8" L04310M RT1-U Open WEST TP7/54 213T /8" L25310T RT1-T Open WEST TP7/54 213T /8" L00310T RT1-N Open OS-E925 S213T /8" L00310T RT1-M Open OS-V303 S215T /8" L06311M RT2-E Open O-V303 S215T /8" L06311M RT2-E Open WEST TP T /8" L04310M RT1-V Open WEST TP T /8" L04310M RT1-U Open WEST TP T /8" L01310T RT1-P Open OS-E T /8" L01310T RT1-P Open L-EHFM2523T 254T /8" L06311M RT2-E Open L-EHFM2523T 254T /8" L06311M RT2-E Open L-EHFM2523T 254T /8" L25310T RT1-T Open L-EFM2513T-5 254T /8" L02310T RT1-S Open WEST TP T /8" L07311M RT2-G Open WEST TP T /8" L07311M RT2-G Open WEST TP T /8" L04310M RT1-U Open L-EFM2515T-5 256T /8" L25310T RT1-T Form P-S (03-18) PN269822R13, Page 18

19 Replacement lower Motors and Starters - FTER PRIL 1, (ont'd) (24 Volt oils) TEF Motor Replacement NOTES: *Starter Required *TEF 1/4 HP, 208/230/480/3 phase - Replacement Motor requires a starter; consult the factory providing wiring diagram or serial number to determine appropriate starter and overload. *TEF 1 HP, 208/230/480/3 phase - Replacement Motor requires a starter; consult the factory providing wiring diagram or serial number to determine appropriate starter and overload. *TEF 1.5 HP, 208/230/480/3 phase - Replacement Motor requires a starter; consult the factory providing wiring diagram or serial number to determine appropriate starter and overload. **Shaft Size hange ** TEF 3 HP, 575/3 phase - Replacement motor shaft size is 7/8 (original motor was 1-1/8 ). ***Shaft Size hange *** TEF 1/4 HP, 120/1 phase - lower motor US T142J9 and replacement blower motor Regal eloit 664 both have a 5/8 shaft size. (original OS motor was 1/2 ). dditional Information: 1) Regal eloit 664 motor replaces US T142J9. 2) US T142J9 blower motor requires starter overload. (NOTE: Highlighted motors do not have internal overload protection and MUST be used with the motor starter and overloads listed. See page 17 for additional information.) See NOTES on page 18 for * and ** explanation. TEF Motor (cont'd) Starter (N10) Starter Overload Type HP Option L Mfr's No. Frame Fla Shaft Volt ph Mfr's No. Min Max GE # TEF 1/2 21, 22, J /8" L00310T RT1-K TEF 1/4 19 ***16074 Regal eloit 664 H /8" L00310T RT1-K TEF 1/4 19 ***16074 Regal eloit 664 H /8" L00310T RT1-K TEF 1/4 19 ***16074 Regal eloit 664 H /8" L00310T RT1-K TEF 1/4 19 * US T14S /8" L00310T RT1-G TEF 1/4 19 * US T14S /8" L00310T RT1-G TEF 1/4 19 * US T14S /8" L00310T RT TEF 1/ STK906 N /2" L00310T RT1-L TEF 1/ N /2" L00310T RT1-J TEF 1/ N /2" L00310T RT1-J TEF 1/ H261 L /2" L00310T RT1-G TEF 1/ H261 L /2" L00310T RT1-G TEF 1/ H261 L /2" L00310T RT TEF 1/2 21, 22, J /8" L00310T RT1-M TEF 1/2 21, 22, J /8" L00310T RT1-K TEF 1/2 21, 22, H274 H /8" L00310T RT1-J TEF 1/2 21, 22, H274 H56 2 5/8" L00310T RT1-J TEF 1/2 21, 22, H274 H56 1 5/8" L00310T RT1-F TEF 1/2 21, 22, H276 J /8" L00310T RT1-F TEF 3/4 21, 22, F353 F /8" L01310T RT1-P TEF 3/4 21, 22, F353 F /8" L00310T RT1-L TEF 3/4 21, 22, F353 F /8" L00310T RT1-L TEF 3/4 21, 22, H580 K56 2 5/8" L00310T RT1-J TEF 3/4 21, 22, H580 K /8" L00310T RT1-J TEF 3/4 21, 22, H580 K /8" L00310T RT1-G TEF 3/4 21, 22, H461 L /8" L00310T RT1-F TEF 1 21, 22, L /8" L01310T RT1-P TEF 1 21, 22, L /8" L00310T RT1-L TEF 1 21, 22, L56 6 5/8" L00310T RT1-L TEF 1 21, 22, 23 * WEG-00118E /8" L00310T RT1-K TEF 1 21, 22, 23 * WEG-00118E /8" L00310T RT1-K TEF 1 21, 22, 23 * WEG-00118E /8" L00310T RT1-H TEF 1 21, 22, H525 H /8" L00310T RT1-G TEF P402 TK56H /8" L02310T RT1-S TEF P402 TK56H 9.5 5/8" L00310T RT1-N TEF P402 TK56H 8.2 5/8" L00310T RT1-N TEF * WEG-00158E /8" L00310T RT1-L TEF * WEG-00158E /8" L00310T RT1-L TEF * WEG-00158E /8" L00310T RT1-J TEF OS T T 1.7 7/8" L00310T RT1-H TEF K200 F182T /8" L04310M RT1-U TEF L3516TM F182T 8.3 7/8" L00310T RT1-M TEF West NP T 6.1 7/8" L00310T RT1-M TEF West NP T 5.6 7/8" L00310T RT1-L TEF West NP T 2.8 7/8" L00310T RT1-K TEF T T 2.3 7/8" L00310T RT1-J Form P-S (03-18) PN269822R13, Page 19

20 Replacement lower Motors and Starters - FTER PRIL 1, (ont'd) (24 Volt oils) TEF Motor (cont'd) Starter (N10) Starter Overload Type HP Option L Mfr's No. Frame Fla Shaft Volt ph Mfr's No. Min Max GE # TEF K222 F184T /8" L04310M RT1-V TEF K222 F184T /8" L02310T RT1-S TEF EM3559T 145T 7.9 7/8" L00310T RT1-N TEF EM3559T 145T 7.2 7/8" L00310T RT1-N TEF EM3559T 145T 3.6 7/8" L00310T RT1-K TEF 3 26 ** EM3559T-5 145T 2.8 7/8" L00310T RT1-K TEF K223 F184T /8" L25310T RT1-T TEF West NP T /8" L02310T RT1-P TEF West NP T /8" L01310T RT1-P TEF West NP T /8" L00310T RT1-L TEF OS T T /8" L00310T RT1-L TEF OS-K305 F215T /8" L06311M RT2-E TEF WEST-NP7/54 213T /8" L04310M RT1-T TEF WEST-NP7/54 213T /8" L25310T RT1-T TEF WEST-NP7/54 213T /8" L00310T RT1-N TEF OS-T T /8" L00310T RT1-M TEF OS-K T /8" L06311M RT2-E TEF West NP T /8" L04310M RT1-V TEF West NP T /8" L04310M RT1-U TEF West NP T /8" L02310T RT1-P TEF OS-T T 9 1-3/8" L00310T RT1-N TEF West NP T /8" L06311M RT2-E TEF West NP T /8" L06311M RT2-E TEF West NP T /8" L25310T RT1-S TEF OS-T T /8" L02310T RT1-S TEF West NP T /8" L07311M RT2-G TEF West NP T /8" L04311M RT2-G TEF West NP T /8" L04310M RT1-U TEF OS-T T /8" L25310T RT1-T rive Options and omponents rive components include the belt, motor pulley, blower pulley, and bushings, if required. The table at the right identifies the RPM range of the drive option. rive options are listed by M No. (NOTE: omponents may have changed. If shaft size is different than listed or if there are no parts listed, check the replacement parts tag and/or contact the distributor or factory service for replacement parts.) elt Tension - heck belt tension. Proper belt tension is important to the long life of the belt and motor. loose belt will cause wear and slippage. Too much tension will cause excessive motor and blower bearing wear. If adjustment is required, adjust belt tension with the adjusting screw on the motor base until the belt can be depressed 1/2" to 3/4". Tighten the lock nut on the adjusting screw. e sure the belt is aligned in the pulleys. OPT RPM RPM RPM RPM OPT OPT OPT Range Range Range Range M M M M M M M M M M M M M M M M M M M M M M rives - Model Series SE Series 6 with Open Motor *istance between blower shaft and motor centerline with belts tensioned properly. **Not for Model 200 or 225. Use a 3/4 "H" blower pulley bushing, ; Use a 1" blower pulley bushing, 92203; Use a 1" Q1 motor pulley bushing, Unit Sizes 125 Motor rive M Nos. Motor Pulley lower Pulley elt *Shaft Voltage Option HP Opt (See Key, chart above) Mfr # ore Mfr # ore Qty Mfr # enterline K1 (115/1); M 1, 2, 3, VL34 1/ K84 3/ /4 L2 K2 (208/1); M 5, 6, 7, 8, VL40 1/ K74 3/ K3 (230/1); M 2, 3, VP34 1/ K84 3/ K5 (208/3); 1/3 L3 M 5, 6, VL40 1/ K74 3/ K6 (230/3); K7 (460/3) M 9, 10, 11, 12, 13, VP34 1/ K46 3/ /2 L4 3/4 L5 1 L6 1-1/2 L7 2 L8 3 L9 K5 (208/3); K6 (230/3); K7 (460/3); K5 (208/3); K6 (230/3); K7 (460/3); M 5, 6, 7, VL34 5/ K64 3/ M 9, 10, VL44 5/ K71H 3/ M 12, 13, 14, 15, 16, 17, VL34 5/ K41 3/ M 7, 8, 9, VL40 5/ K64 3/ M 11, 12, 13, 14, VL34 5/ K46 3/ M 16, 17, 18, 19, 20, 21, VL40 5/ K41 3/ M 9, 10, 11, 12, 13, 14, VL34 5/ K46 3/ M 16, 17, 18, 19, 20, 21, VL40 5/ K41 3/ M 11,12, VL44 5/ K64 3/ M 14, 15, 16, VL40 5/ K49 3/ M 18, 19, 20, 21, VL40 5/ K41 3/ M 13, 14,15,16, VL40 5/ K49 3/ M 18, 19, 20, 21, VL40 5/ K41 3/ M 13, 14, 15, 16, VM50 5/ K140 3/ M 18, 19, 20, 21, 22, 23, VM50 5/ K74 3/ Form P-S (03-18) PN269822R13, Page 20

21 Unit Sizes Motor rive M Nos. Motor Pulley lower Pulley elt *Shaft Voltage Option HP Opt (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline M 2, 3, VL34 5/ K /2 L4 M 5, 6, 7, VL34 5/ K M 9, 10, VL34 5/ K K1 (115/1); K2 (208/1); M 5, 6, 7, VL34 5/ K /4 L5 K3 (230/1); M 9, 10, 11, 12, 13, 14, VL34 5/ K K5 (208/3); M 7, VL34 5/ K L6 K6 (230/3); M 9, 10, 11, 12, 13, VL34 5/ K K7 (460/3); M 15, 16, VL40 5/ K /2 L7 2 L8 3 L9 5 L10 1/2 L4 3/4 L5 1 L6 1-1/2 L7 2 L8 3 L9 5 L10 3/4 L5 1 L6 1-1/2 L7 2 L8 3 L9 5 L10 K5 (208/3); K6 (230/3); K7 (460/3); K5 (208/3); K6 (230/3); K7 (460/3); K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3); K5 (208/3); K6 (230/3); K7 (460/3); K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K5 (208/3); K6 (230/3); K7 (460/3); M 9, 10, VL44 5/ K M 12, 13, 14, 15, VL44 5/ K71H M 17, VL40 5/ K M 9, 10, VL40 5/ K M 12, 13, 14, 15, 16, VL44 5/ K M 18, 19, VL40 5/ K M 13, 14, 15, 16, VM50 5/ K M 18, 19, 20, VM50 5/ K M 16, 17, 18, 19, 20, 21, VP36 7/ T M 20, 21, 22, VP50 7/ K M 2, 3, VL34 5/ K M 5, 6, 7, VL34 5/ K M 5, 6, VL34 5/ K M 8, 9, 10, VL34 5/ K M 7, 8, 9, 10, VL34 5/ K M 12, 13, 14, 15, VL34 5/ K M 9, 10, VL40 5/ K M 12, 13, 14, 15, VL44 5/ K M 17, 18, 19, 20, 21, 22, VL44 5/ K M 9, 10, VL40 5/ K M 12, 13, 14, 15, VL44 5/ K M 17, 18, 19, 20, 21, 22, VL44 5/ K M 9, 10, 11, IVL40 5/ K M 13, 14, 15, 16, IVL40 5/ K M 18, 19, 20, 21, IVL40 5/ K M 15, 16, 17, 18, VP36 7/ T M 20, 21, 22, VP50 7/ K M 2, 3, VL34 5/ K M 5, VL40 5/ K M 3, 4, 5, VL34 5/ K71H M 7, 8, 9, 10, VL34 5/ K M 6, 7, 8, VL40 5/ K71H M 10, 11, 12, VL44 5/ K M 14, 15, 16, 17, VL40 5/ K M 9, 10, VL40 5/ K M 12, 13, 14, 15, VL44 5/ K M 17, 18, VL40 5/ K M 9, 10, 11, VL40 5/ K M 13, 14, 15, 16, 17, 18, VL40 5/ K M 20, 21, 22, 23, 24, 25, VL40 5/ K M 12, 13, 14, 15, 16, VP42 7/ K M 18, 19, 20, 21, VP50 7/ K rive omponents - Model SE Series 6 w/totally Enclosed (TEF) Motor (See drive information, page 20) Unit Sizes 125 Motor rive M Nos. Motor Pulley lower Pulley elt *Shaft Voltage Option HP Opt (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline 1/4 L19 1/3 L20 1/2 L21 3/4 L22 1 L23 1-1/2 L24 2 L25 3 L26 K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3); K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3); K5 (208/3); K6 (230/3); K7 (460/3); M 1, 2, 3, VL34 5/ K84 3/ M 5, 6, 7, 8, VL40 5/ K74 3/ M 2, 3, VP34 1/ K84 3/ M 5, 6, 7, VL40 1/ K74 3/ M 9, 10, 11, 12, 13, VP34 1/ K46 3/ M 5, 6, 7, VL34 5/ K64 3/ M 9, 10, VL44 5/ K71H 3/ M 12, 13, 14, 15, 16, 17, VL34 5/ K41 3/ M 7, 8, 9, VL40 5/ K64 3/ M 11, 12, 13, 14, VL34 5/ K46 3/ M 16, 17, 18, 19, 20, 21, VL40 5/ K41 3/ M 9, 10, 11, 12, 13, 14, VL34 5/ K46 3/ M 16, 17, 18, 19, 20, 21, VL40 5/ K41 3/ M 11, 12, VL44 5/ K64 3/ M 14, 15, 16, VL40 5/ K49 3/ M 18, 19, 20, 21, VL40 5/ K41 3/ M 11, 12, VL44 7/ K64 3/ M 14, 15, 16, VL40 7/ K49 3/ M 18, 19, 20, 21, VL40 7/ K41 3/ M 13, 14, 15, 16, VL40 7/ K49 3/ M 18, 19, 20, 21, VL40 7/ K41 3/ M 13, 14, 15, 16, VM50 7/ K140 3/ M 18, 19, 20, 21, 22, 23, VM50 7/ K74 3/ Form P-S (03-18) PN269822R13, Page 21

22 rive omponents - Model SE Series 6 w/totally Enclosed (TEF) Motor - (cont'd) Unit Sizes Motor rive M Nos. Motor Pulley lower Pulley elt *Shaft Voltage Option HP Opt (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline 1/3 L20 1/2 L21 3/4 L22 1 L23 1-1/2 L24 2 L25 3 L26 K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3); K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K5 (208/3); K6 (230/3); K7 (460/3); 1/2 L21 K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3); 3/4 L22 1 L23 1-1/2 L24 2 L25 3 L26 3/4 L22 1 L23 1-1/2 L24 K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3); K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K5 (208/3); K6 (230/3); K7 (460/3); K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) 2 L25 K5 (208/3); K6 (230/3); K7 (460/3) 3 L26 K5 (208/3); K6 (230/3); K7 (460/3); M 2, 3, VL34 1/ K M 5, 6, VL34 1/ K M 2, 3, VL34 5/ K M 5, 6, 7, VL34 5/ K M 9, 10, VL34 5/ K M 5, 6, 7, VL34 5/ K M 9, 10, 11, 12, 13, 14, VL34 5/ K M 7, VL34 5/ K M 9, 10, 11, 12, 13, VL34 5/ K M 15, 16, VL40 5/ K M 9, 10, VL44 5/ K71H M 12, 13, 14, 15, VL44 5/ K M 17, VL40 5/ K M 9, 10, VL44 7/ K71H M 12, 13, 14, 15, VL40 7/ K M 17, VL40 7/ K M 9, 10, VL40 7/ K M 12, 13, 14, 15, 16, VL44 7/ K M 18, 19, VL40 7/ K M 13, 14, 15, 16, VL40 7/ K M 18, 19, 20, VL40 7/ K M 2, 3, VL34 5/ K M 5, 6, 7, VL34 5/ K M 5, 6, VL34 5/ K M 8, 9, 10, VL34 5/ K M 7, 8, 9, 10, VL34 5/ K M 12, 13, 14, 15, VL34 5/ K M 9, 10, VL40 5/ K M 12, 13, 14, 15, VL44 5/ K M 17, 18, 19, 20, 21, 22, VL44 5/ K M 9, 10, VL40 7/ K M 12, 13, 14, 15, VL44 7/ K M 17, 18, 19, 20, 21, 22, VL44 7/ K M 9, 10, VL40 7/ K M 12, 13, 14, 15, VL44 7/ K M 17, 18, 19, 20, 21, 22, VL44 7/ K M 13, 14, 15, 16, VL40 7/ K M 18, 19, 20, 21, VM50 7/ K M 2, 3, VL34 5/ K M 5, VL40 5/ K M 3, 4, 5, VL34 5/ K71H M 7, 8, 9, 10, VL34 5/ K M 6, 7, 8, VL40 5/ K71H M 10, 11, 12, VL44 5/ K M 14, 15, 16, 17, VL40 5/ K M 6, 7, 8, VL40 7/ K71H M 10, 11, 12, VL44 7/ K M 14, 15, 16, 17, VL40 7/ K M 9, 10, VL40 7/ K M 12, 13, 14, 15, VL44 7/ K M 17, 18, 19, VL40 7/ K M 9, 10, 11, 12, VL44 7/ K M 14, 15, 16, 17, 18, VL44 7/ K *istance between blower shaft and motor centerline with belts tensioned properly. **Not for Model 200 or 225. Use a 3/4 "H" blower pulley bushing, ; Use a 1" blower pulley bushing, 92203; Use a 1" Q1 motor pulley bushing, Form P-S (03-18) PN269822R13, Page 22

23 rive omponents - Model SE Series 6 with Premium Efficiency Motor (See drive information, top of page 20) *istance between blower shaft and motor centerline with belts tensioned properly. **Not for Model 200 or 225. Use a 3/4 "H" blower pulley bushing, ; Use a 1" blower pulley bushing, 92203; Use a 1" Q1 motor pulley bushing, Unit Sizes 125 Motor Voltage rive M Nos. Motor Pulley lower Pulley elt *Shaft HP Opt Option (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline M 9, 10, 11, 12, 13, 14, VP34 7/ K46 3/ L36 M 16, 17, 18, 19, 20, 21, VL40 7/ K41 3/ M 11, 12, VL44 7/ K64 3/ /2 L37 K5 (208/3); M 14, 15, 16, VL40 7/ K49 3/ K6 (230/3); M 18, 19, 20, 21, VL40 7/ K41 3/ K7 (460/3); M 13, 14, 15, 16, VL40 7/ K49 3/ L38 3 L39 1 L /2 L L38 3 L39 1 L36 1-1/2 L L L39 K5 (208/3); K6 (230/3); K7 (460/3); K5 (208/3); K6 (230/3); K7 (460/3); 1 L36 K5 (208/3); K6 (230/3); K7 (460/3); 1-1/2 L37 2 L38 3 L39 K5 (208/3); K6 (230/3); K7 (460/3); M 18, 19, 20, 21, VL40 7/ K41 3/ M 13, 14, 15, 16, VM50 7/ K140 3/ M 18, 19, 20, 21, 22, 23, VM50 7/ K74 3/ M 7, VP34 7/ K M 9, 10, 11, 12, 13, VP34 7/ K M 15, 16, VL40 7/ K M 9, 10, VL44 7/ K71H M 12, 13, 14, 15, VL44 7/ K M 17, 18, 19, VL40 7/ K M 9, 10, VL40 7/ K M 12, 13, 14, 15, 16, VL44 7/ K M 18, 19, VL40 7/ K M 13, 14, 15, 16, VL40 7/ K M 18, 19, 20, VL40 7/ K M 7, 8, 9, 10, VP34 7/ K M 12, 13, 14, 15, VP34 7/ K M 9, 10, VL40 7/ K M 12, 13, 14, 15, VL44 7/ K M 17, 18, 19, 20, 21, 22, VL44 7/ K M 9, 10, VL40 7/ K M 12, 13, 14, 15, VL44 7/ K M 17, 18, 19, 20, 21, 22, VL44 7/ K M 13, 14, 15, 16, VL40 7/ K M 18, 19, 20, 21, VM50 7/ K M 3, 4, 5, VP34 7/ K71H M 7, 8, 9, 10, VP34 7/ K M 6, 7, 8, VL40 7/ K71H M 10, 11, 12, VL44 7/ K M 14, 15, 16, 17, VL40 7/ K M 9, 10, VL40 7/ K M 12, 13, 14, 15, VL44 7/ K M 17, 18, 19, VL40 7/ K M 9, 10, 11, 12, VL44 7/ K M 14, 15, 16, 17, 18, VL44 7/ K rive omponents - Model SE Series with Two-Speed Motor (See drive information, top of page 20) *istance between blower shaft and motor centerline with belts tensioned properly. **Not for Model 200 or 225. Use a 1" blower pulley bushing, Unit Sizes 125 Motor Voltage rive M Nos. Motor Pulley lower Pulley elt *Shaft HP Opt Option (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline 1 L45 M 9, 10, 11, 12, 13, 14, VP34 7/ K46 3/ M 16, 17, 18, 19, 20, 21, VL40 7/ K41 3/ M 11, 12, VL44 7/ K64 3/ /2 L46 M 14, 15, 16, VL40 7/ K49 3/ M 18, 19, 20, 21, VL40 7/ K41 3/ L47 3 L48 1 L /2 L L L48 1 L45 K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) K1 (115/1); K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3) 1-1/2 L46 2 L47 K5 (208/3); K6 (230/3); K7 (460/3) 3 L48 M 13, 14, VP50 1-1/ K71 3/ M 16, 17, 18, 19, VP50 1-1/ K59 3/ M 21, 22, 23, VP50 1-1/ K57 3/ M 13, 14, VP50 1-1/ K71 3/ M 16, 17, 18,19, VP50 1-1/ K59 3/ M 21, 22 23, VM50 1-1/ K57 3/ M 7, VP34 7/ K M 9, 10, 11, 12, 13, VP34 7/ K M 15, 16, VL40 7/ K M 9, 10, VL44 7/ K71H M 12, 13, 14, 15, VL44 7/ K M 17, 18, 19, VL40 7/ K M 12, 13, 14, 15, VP50 1-1/ K M 17, 18, 19, VP50 1-1/ K M 21, 22, 23, VP50 1-1/ K M 13, 14, 15, VP50 1-1/ K M 17, 18, 19, VP50 1-1/ K M 21, 22, 23, VP50 1-1/ K M 7, 8, 9, 10, VP34 7/ K M 12, 13, 14, 15, VP34 7/ K M 9, 10, VL40 7/ K M 12, 13, 14, 15, VL44 7/ K M 17, 18, 19, 20, 21, 22, VL44 7/ K M 12, 13, 14, 15, VP50 1-1/ K M 17, 18, 19, VP50 1-1/ K M 21, 22, 23, VP50 1-1/ K M 13, 14, 15, VP50 1-1/ K M 17, 18, 19, VP50 1-1/ K M 21, 22, 23, VP50 1-1/ K Form P-S (03-18) PN269822R13, Page 23

24 rive omponents (cont'd) - Model SE Series with Two-Speed Motor (See drive information, top of page 20) Unit Sizes Motor Voltage rive M Nos. Motor Pulley lower Pulley elt *Shaft HP Opt Option (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline 1 L45 M 3, 4, 5, VP34 7/ K71H M 7, 8, 9, 10, VP34 7/ K M 6, 7, 8, VL40 7/ K71H /2 L46 M 10, 11, 12, VL44 7/ K M 14, 15, 16, 17, VL40 7/ K K5 (208/3); M 12, 13, 14, 15, VP50 1-1/ K L47 K6 (230/3); M 17, 18, 19, VP50 1-1/ K K7 (460/3) M 21, 22, 23, VP50 1-1/ K L48 5 L10 M 12, 13, 14, 15, VP50 1-1/ K M 17, 18, 19, VP50 1-1/ K M 21, 22, 23, VP50 1-1/ K M 12, 13, 14, 15, 16, VP42 7/ K M 18, 19, 20, 21, VP50 7/ K rive omponents - Model SSL with Open Motor (See drive information, top of page 20) Unit Sizes Motor rive M Nos. Motor Pulley lower Pulley elt *Shaft Voltage Option HP Opt (See Key, chart page 20) Mfr # ore Mfr # ore Qty Mfr # enterline 1 L6 M 2, 3, VL34 5/ K84 1-3/ M 5, 6, VL34 5/ K71H 1-3/ /2 L7 K1 (115/1); K2 (208/1); M 3, 4, 5, 6, VL34 5/ K71H 1-3/ K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3); M 8, 9, 10, VL44 5/ K74 1-3/ L8 3 L9 5 L10 ll 7-1/2 L11 "L" Units 10 L12 **15 L15 **20 L16 ***15 L15 ***20 L16 K2 (208/1); K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3); K5 (208/3); K6 (230/3); K7 (460/3); K5 (208/3); K6 (230/3); K7 (460/3); M 3, 4, 5, 6, VP34 7/ K71H 1-3/ M 8, 9, 10, VL44 7/ K71H 1-3/ M 12, 13, 14, 15, VL44 7/ K56H 1-3/ M 7, 8, VM50 7/ K / M 10, 11, 12, VL44 7/ K / M 14, 15, 16, 17, VM50 7/ K / M 8,9,10, VP42 7/ K / M 12,13,14, VP36 7/ K / M 16, 17, 18, 19, VP42 7/ K / M 10, VP62 1-3/ K / M 12, VP62 1-3/ K / M 14, 15, VP62 1-3/ T86 1-3/ X M 17, 18, 19, VP65 1-3/ K80H 1-3/ X M 10, VP62 1-3/ K / M 12, VP62 1-3/ K / M 14,15, VP62 1-3/ T86 1-3/ X M 17, 18, 19, VP65 1-3/ K80H 1-3/ X **M 15, 16, 17, 18, 19, MVPP / T66H G 1-7/ **M 21, 22, 23, MVPP / K65H 1-7/ **M 17, 18, 19, 20, 21, 22, 23, MVPP / K65H 1-7/ X ***M 15, 16, E 2MVP7084P 1-5/8" K120H 1-7/ X ***M 18, 19, 20, F 2MVP8094Q 1-5/8" V110 G 1-7/ X ***M 22, 23, E 2MVP7084P 1-5/8" V90 G 1-7/ X ***M E 2MVP7084P 1-5/8" K120H 1-7/ X67 ***M 18, 19, 20, F 2MVP8094Q 1-5/8" V110 G 1-7/ X69 ***M 22, 23, E 2MVP7084P 1-5/8" V90 G 1-7/ X64 *istance between blower shaft and motor centerline with belts tensioned properly. ** Three-Groove rives ***Two-Groove rives Use 1-3/16 "H" lower Pulley ushing, ; Use 1-3/16 "Q1" lower Pulley ushing, 39460; Use 1-7/16 "H" lower Pulley ushing, 89659; Use 1-7/16 "" lower Pulley ushing, ; E Use 1-5/8 "P2" Motor Pulley ushing, ; F Use 1-5/8 "Q2" Motor Pulley ushing, ; G Use 1-7/16 "P1" lower Pulley ushing, ; rive omponents for Totally Enclosed Motors (See drive information, top of page 20) Unit Motor rive M Nos. Motor Pulley lower Pulley elt *Shaft Voltage Option Sizes HP Opt (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline K1 (115/1); K2 (208/1); K3 (230/1); K5 M 2, 3, VL34 5/ K84 1-3/ L23 (208/3); K6 (230/3); K7 (460/3); M 5, 6, VL34 5/ K71H 1-3/ K1 (115/1); K2 (208/1); K3 (230/1); M 3, 4, 5,6, VL34 5/ K71H 1-3/ K5 (208/3); K6 (230/3); K7 (460/3) M 8, 9, 10, VL44 5/ K74 1-3/ /2 L24 M 3, 4, 5,6, VP34 7/ K71H ll 1-3/ M 8, 9, 10, VL44 7/ K74 1-3/ "L" M 3, 4, 5, 6, VP34 7/ K71H 1-3/ K1 (115/1); K3 (230/1); K5 (208/3); 2 L25 M 8, 9, 10, VL44 7/ K71H K6 (230/3); K7 (460/3); 1-3/ M 12, 13, 14, 15, VL44 7/ K56H 1-3/ M 7, 8, VM50 7/ K / K1 (115/1); K3 (230/1); K5 (208/3); M 10, 11, 12, VL44 7/ K / K6 (230/3); K7 (460/3) M 14, 15, 16, 17, VM50 7/ K / M 7, 8, VM50 7/ K / L26 M 10, 11, 12, VL44 7/ K / ll M 14, 15, 16, 17, VM50 7/ K / "L" 5 L27 K3 (230/1); K5 (208/3); K6 (230/3); K7 (460/3); M 8,9, 10, VP42 1-1/ K / M 12, 13, 14, VP50 1-1/ K / M 16, 17, 18, 19, VP42 1-1/ K / Form P-S (03-18) PN269822R13, Page 24

25 Unit Sizes ll Motor rive M Nos. Motor Pulley lower Pulley elt *Shaft Voltage Option HP Opt (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline M 10, VP62 1-3/ K / /2 L32 M 12, VP62 1-3/ K / M 14, 15, VP62 1-3/ T86 1-3/ X K3 (230/1); K5 (208/3); K6 (230/3); M 17, 18, 19, VP65 1-3/ K80H X K7 (460/3); 10 L33 rive omponents for Premium Efficiency Motors (See drive information, top of page 20) Unit Sizes ll "L" Units M 10, VP62 1-3/ K / M 12, VP62 1-3/ K / M 14, 15, VP62 1-3/ T86 1-3/ X M 17, 18, 19, VP65 1-3/ K80H 1-3/ X "L" **15 L34 **M 15, 16, MVP7084P E 1-5/ K120H 1-7/ X Units & 20 L35 **M 18, 19, 20, MVP8094Q F 1-5/ V110 G 1-7/ X **M 22, 23, MVP7084P E 1-5/ V90 G 1-7/ X ***15 L34 ***M 15, 16, E 2MVP7084P 1-5/ K120H 1-7/ X K5 (208/3); K6 (230/3); K7 (460/3); ***M 18, 19, 20, MVP8094Q 1-5/ V110 G 1-7/ X ***M 22, 23, E 2MVP7084P 1-5/ V90 G 1-7/ X ***M E 2MVP7084P 1-5/ K120H 1-7/ X ***20 L35 ***M 18, 19, 20, F 2MVP8094Q 1-5/ V110 G 1-7/ X ***M 22, 23, E 2MVP7084P 1-5/ V90 G 1-7/ X *istance between blower shaft and motor centerline with belts tensioned properly. ** Three-Groove rives ***Two-Groove rives Use 1-3/16 "H" lower Pulley ushing, Use 1-7/16 "" lower Pulley ushing, G Use 1-7/16 "P1" lower Pulley ushing, Use 1-3/16 "Q1" lower Pulley ushing, E Use 1-5/8 "P2" Motor Pulley ushing, Use 1-7/16 "H" lower Pulley ushing, F Use 1-5/8 "Q2" Motor Pulley ushing, Motor Voltage rive M Nos. Motor Pulley lower Pulley elt *Shaft HP Opt Option (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline 1 L36 M 2, 3, VP34 7/ K84 1-3/ M 5, 6, VP34 7/ K71H 1-3/ /2 L37 M 3, 4, 5, 6, VP34 7/ K71H 1-3/ M 8, 9, 10, VL44 7/ K74 1-3/ M 3, 4, 5, 6, VP34 7/ K71H 1-3/ L38 M 8, 9, 10, VL44 7/ K71H 1-3/ M 12, 13, 14, 15, VL44 7/ K56H 1-3/ M 7, 8, VM50 7/ K / L39 M 10, 11, 12, VL44 7/ K / M 14, 15, 16, 17, VM50 7/ K / M 8, 9, 10, VP42 1-1/ K / L40 M 12, 13, 14, VP50 1-1/ K34 1-3/ M 16, 17, 18, 19, VP42 1-1/ K / K5 (208/3); M 10, VP62 1-3/ K / /2 L41 K6 (230/3); M 12, VP62 1-3/ K / K7 (460/3); M 14, 15, VP62 1-3/ T86 1-3/ X M 17, 18, 19, VP65 1-3/ K80H 1-3/ X M 10, VP62 1-3/ K / L42 M 12, VP62 1-3/ K / M 14, 15, VP62 1-3/ T86 1-3/ X M 17, 18, 19, VP65 1-3/ K80H 1-3/ X L43 **M 15, 16, MVP7084P 1-5/ K120H 1-7/ X **15 **M 18, 19, 20, MVP8094Q E 1-5/ V110 F 1-7/ X & 20 L44 **M 22, 23, MVP7084P 1-5/ V90 F 1-7/ X ***M 15, 16, MVP7084P 1-5/ K120H 1-7/ X67 ***15 L43 ***M 18, 19, 20, MVP8094Q E 1-5/ V110 F 1-7/ X69 ***M 22, 23, MVP7084P 1-5/ V90 F 1-7/ X64 ***M MVP7084P 1-5/ K120H 1-7/ X67 ***20 L44 ***M 18, 19, 20, MVP8094Q E 1-5/ V110 F 1-7/ X69 ***M 22, 23, MVP7084P 1-5/ V90 F 1-7/ X64 *istance between blower shaft and motor centerline with belts tensioned properly. ** Three-Groove rives ***Two-Groove rives Use 1-3/16 "H" lower Pulley ushing, ; Use 1-3/16 "Q1" lower Pulley ushing, 39460; Use 1-7/16 "H" lower Pulley ushing, 89659; Use 1-7/16 "" lower Pulley ushing, ; E Use 1-5/8 "P2" Motor Pulley ushing, ; F Use 1-5/8 "Q2" Motor Pulley ushing, ; G Use 1-7/16 "P1" lower Pulley ushing, ; rive omponents for Two- Speed Motors (See drive information, top of page 20) Unit Sizes ll "L" Units Motor Voltage rive M Nos. Motor Pulley lower Pulley elt *Shaft HP Opt Option (See Key, chart on page 20) Mfr # ore Mfr # ore Qty Mfr # enterline 1 L45 M 2, 3, VP34 7/ K84 1-3/ M 5, 6, VP34 7/ K71H 1-3/ /2 L46 M 3, 4, 5, 6, VP34 7/ K71H 1-3/ M 8, 9, 10, VL44 7/ K74 1-3/ M 4, VP50 1-1/ K / L47 M 6, 7, 8, VP44 1-1/ K84 1-3/ M 10, 11, 12, VP44 1-1/ K85H 1-3/ M 14, 15, 16, 17, 18, VP44 1-1/ K60 1-3/ X L48 5 L49 7-1/2 L50 10 L51 K5 (208/3); K6 (230/3); K7 (460/3) M 4, VP50 1-1/ K / M 6, 7, 8, VP44 1-1/ K84 1-3/ M 10, 11, 12, VP44 1-1/ K75H 1-3/ M 14, 15, 16, 17, 18, VP44 1-1/ K60 1-3/ X M 8, 9, 10, VP60 1-3/ K / M 12, 13, 14, VP60 1-3/ K90 1-3/ X M 16, 17, 18, 19, VP60 1-3/ T70 1-3/ M 10, VP62 1-3/ K / M 12, VP62 1-3/ K / M 14, 15, VP62 1-3/ T86 1-3/ X M 17, 18, 19, VP65 1-3/ K80H 1-3/ X M 13, 14, 15, MPV / K80H 1-3/ M 17, 18, 19, 20, 21, MPV / K70H 1-3/ *istance between blower shaft and motor centerline with belts tensioned properly. ** Three-Groove rives ***Two-Groove rives Use 1-3/16 "H" lower Pulley ushing, Use 1-3/16 "Q1" lower Pulley ushing, Form P-S (03-18) PN269822R13, Page 25

26 Exterior abinet Parts - Furnace Section Models S and SE (Quantity not listed in parenthesis is one.) Furnace Section Exterior abinet Parts - Models S uct Furnace and Model SE Furnace/lower Packaged Unit Gray Sealant (3M 900 uct Sealer Fast ond), irflow irflow Model S uct Furnace ode escription pplication Size / / asing Top ssembly with S Series insulation SE Series Right asing Side Panel w/insulation - S SE orner Leg - Right Front S, SE orner Leg - Right Rear S SE Top Front & Top ack (2) w/insulation - S SE Left Rear orner Leg (control side) Left Front orner Leg (control side) ottom Front & Rear Panel ssembly w/insulation (2) Venter Panel ssembly ccess Panel ssembly ottom Left Side Panel with S (with insulation) Grommet & Sight Hole over SE Series Vinyl Grommet ottom Pan ssembly luminized, Stainless Steel Hanger ssembly (2) Mounting Support (below) (4 required) Louver Frame with Horizontal Louvers (Horizontal & vertical louvers are optional on SE.) Horizontal Louver only (5)9923 (5)9887 (5)9847 (5)9808 (10)9769 (10)9733 (10) Vertical Louver only (4)9554 (6)9554 (8)9554 (10)9554 (12)9554 (14) Maroon Touchup Paint for Louvers, 12 oz can ondensate rain Kit same as Opt S ode Mounting Supports for Models S and SE Shipping olt Lug ontrol ccess Panel Retaining Screw Support, (4 required) odes 214, 215, & Horizontal and Vertical Louvers irflow lower Section ode ondensate rain Kit Model SE Furnace Section Model SE as illustrated above may be used at the four corner support locations. o not use this type of support at the center support locations (between the furnace and the blower section). t the center locations, a field-fabricated, angle-iron brace support must extend horizontally, jointly supporting a portion of both the furnace and the blower cabinet. ll supports must be noncombustible. ottom of Furnace asing x 1-1/2 rass olt and Nut Gasket 3/4 Pipe Waste Nut Form P-S (03-18) PN269822R13, Page 26

27 lower abinet and omponents - Model SE SE Rear View Showing Standard Inlet ir Opening, ode 220 (does not accommodate dampers) For blower motor, see pages & For drive components, see pages lower abinet Parts - Model SE (Note: Filter rack & filters are optional and are not part of ode 220 or 220) ode Standard ode Optional lower abinet for lower abinet that Model SE 225 ccommodates beginning ampers 221 7/ ode lower abinet Parts Size escription / / / Standard abinet Shipped knocked down; Optional abinet assembly is required omponents: pplies to: Qty 221 oor without insulation Std abinet oor with insulation Opt abinet Top & ottom without insulation Std abinet Top with insulation Opt abinet Std abinet orner Support Std & Opt (2)Std; (1)Opt Hanger Support Std & Opt Hanger ssembly Std & Opt uct onnecting ngle Opt abinet Hole Plug 1/2" Std & Opt End Panel only (less insulation) Opt abinet End Panel Insulation Opt abinet ottom Left Side Opt abinet ottom Right Side Opt abinet Rear ottom Section Opt abinet Inlet ap Opt abinet ottom Insulation Opt abinet Filter Racks (less filters; assembly required) Filter Support Filter rack is Intermediate Filter Support ssembly optional. It fits either Std or Opt cabinet Filter Stop Filters - See chart below.(only 2" replacement filters are available; 1" filters in sizes listed should be obtained locally) Inlet Screen, no dampers (same as Opt Z3) Inlet Screen, with dampers (same as Opt Z4) Screens for horizontal & bottom openings w/dampers (same as Opt Z5) ode Optional Filters Size / / / Permanent 16x20x2 (2) Permanent 16x25x2 (2) (3) Permanent 20x20x2 (2) (2) (1) Permanent 20x25x2 (2) (2) (3) (2) Pleated 16x20x2 (2) Pleated 16x25x2 (2) (3) Pleated 20x20x2 (2) (2) (1) Pleated 20x25x2 (2) (2) (3) (2) Form P-S (03-18) PN269822R13, Page 27

28 lower abinet and omponents - Model SE (cont'd) ode Motor djustment racket ssembly for less than 1HP motor ode Motor Support for less than 1 HP motor 5/16-18 x 4 lg Hex Head olt 5/16-18 x 4 lg Hex Head olt 5/16-18 Lock Nut 5/16-18 Hex Nut Rubber Grommet ode Replacement Rubber Feet and Hardware odes 253, 254, and Motor Mounting Plate ssy for motors 1HP and larger (2) Rod olts, (2) olt, 16248; (2) Washers, 1087; and (2) Nuts, 6554 ode escription pplication Size / / / lower ack ssembly lower Mtr Mounting racket w/less than 1HP mtr Motor djustment racket ssembly lower Motor Mounting Plate w/1hp & larger mtr lower Motor Mounting Plate Left Support lower Motor Mounting Plate Right Support Rubber Feet and Mounting Hardware lower, omplete with Shaft and earings 1357, Lau , Lau EXT-P lower, Right Side less shaft and bearings , Lau RH , Lau RH lower, Left Side less shaft and bearings , Lau LH , Lau LH lower Shaft 11302, 18x3/ , 19x , 39-1/4x , 44-5/8x1 259 Key 3/16" sq x 1-3/3" lg lower earings (2)7310, all SF-3/4 (2)10437, all SR16-1 Model SSL (parts apply to each furnace section) Model SSL rrangement Model Furnace Sections lower Size Qty S Size abinet L Type L Type L Type L Type L Type L Type Furnace Section Exterior abinet Parts - Model SSL only (parts apply to each furnace section) onnector and Filler Parts (not illustrated) for onnecting Heat Exchangers in Model SSL Systems with Two or Three Furnaces lower abinet (L Type) - see page 25 for parts Furnace Section ode escription ottom Front & Rear Panel (2) Furnace luminized ottom Pan Stainless Steel Top Front & Rear Panel (2) asing Top ssembly Furnace Right Side Panel ssembly Furnace ottom Left Side Panel Vinyl Grommet 15021, 3/4" , 1/2" 15021, 3/4" 277 Furnace enter Left Side Panel Furnace Top Left Side Panel ssembly Left Rear Furnace Leg (not illustrated) Left Front Furnace Leg Right Rear Furnace Leg (not illustrated) Right Front Furnace Leg Top Seal race (not illustrated) SSL Size / Top Filler ssembly -- (1) (1) (1) (2) (2) Side Filler -- (2) Top & tm uct onnector -- (2) (2) (2) (2) (2) Side uct onnector -- (2) Form P-S (03-18) PN269822R13, Page Furnace Section

29 Model SSL lower abinet and lower Parts ode escription 500/ / /800/ 1200 abinet tm - Rt Half - solid (no opening) abinet tm - Lft Half - solid (no opening) abinet tm - Rt Half - return air opening abinet tm - Lft Half - return air opening End Panel ssembly - solid (no opening) End Panel ssembly - solid (no opening) with double-wall construction (Opt Y3) 290 End Panel ssembly - 100% opening End Panel ssembly - 100% opening with double-wall construction (Opt Y3) lower oor - standard (2) lower oor - with double-wall construction (Opt Y3) (2) Filter abinet oor ssembly (2) Filter abinet oor ssembly - with double-wall construction (Opt Y3) (2) Replacement oor Latch lower abinet Front Top Section ssy lower abinet Rear Top Section ssy lower abinet Top Insulation Retainer Filter abinet Top Insulation Retainer L abinet Leg #1, Left L abinet Leg #2, Right orner Post (2) abinet Leg ap Left abinet Leg ap Right abinet Intermediate Post (2) abinet Intermediate Post ap (2) orner Post ap (2) abinet Top Front Panel abinet ottom Front Panel abinet Vertical lower Support Left abinet Vertical lower Support Right abinet Horizontal lower Support (2) abinet and Panel Support abinet Top Support ottom Filter Rack ssy - 1 & 2" filters Rear Filter Rack ssy - 1 & 2" filters (2) (2) (2) Front Filter Rack ssy - 1 & 2" filters (2) (2) (2) Top Filter Rack ssy - 1 & 2" filters Top oor Seal (2) lower abinet dapter ack ssembly Motor Mounting Plate ssembly Motor Mounting olts See illustration, page 26. OE Replacement oor Latch Kit, ssembly sequence for installing replacement door latch. (2) Water Resistant Neoprene Washers Pawl Retainer ross-reference of End and ottom Panel Options to abinet Openings abinet Option End Panel tm Panel Solid 100% Open Solid 100% Open Std X X R-4 X X R-8 X X R-9 X X R-11 X X R-12 X X R-13 X X R-14 X X R-15 X X R-16 X X R-17 X X R-18 X X R-24 X X ode escription 500/ / /800/ 1200 < 15HP motor (2) Motor Mounting Support <15HP w/ (Opt ssembly (support rails 321 P12) vibration (qty changes to one because for motor mounting plate, isolation assembly includes both rails) ode 319) 15 & 20 HP 322 Motor djustment ngle (w/ ode 322 & 322 allows motor to be moved for drive adjustment) < 15HP motor <15HP w/ (Opt P12) vibration isolation 15 & 20 HP Motor djustment olt 3/8-16 x 7" lg (used with 322 & ) 322 djustment olt Hex Nut 3/ (used with 322 & ) 323 lower (Housing and Wheel) Lau 15 x 9, (2) 1-3/ lower (Housing and Wheel ) Lau 15 x 11, 1-3/16 -- (2)14469 lower Shaft 1-3/16 x 37" long lower Shaft 1-3/16 x 42-1/2" long lower Shaft 1-3/16 x 48" long lower earing, 1-3/16", less than 5HP (2) 14474, Fafair #E Vertical lower Support - Right Vertical lower Support - Left earing racket, 1-3/16 (2) 24233, Lau # Heavy uty lower Right Lau 15 x 9 (15-20HP motors) Heavy uty lower Left Lau 15 x 9 (15-20HP motors) Heavy uty lower Right Lau 15 x 11 (15-20HP motors) Heavy uty lower Left Lau 15 x 11 (15-20HP motors) lower Shaft Key (used w/heavy duty blowers) (4) lower Shaft Heavy uty lower 1-7/16 x 42" long lower Shaft Heavy uty lower 1-7/16 x 47-1/2" long lower Shaft Heavy uty lower 1-7/16 x 53" long Pillow lock earing, 1-7/16 ore, odge (2) P2S2107R (replaces ) 337 lass II lower Support - Right Side lass II lower Support - Left Side ir Flow Switch Pitot Sense Probe (part of Option W1) Parts for Motor Support, Mounting, and djusting (see page 26) 322,, 321 Metal Washer Shaft with Slotted Head with irectional rrow Set Screw 1/4 Hole in oor Panel Form P-S (03-18) PN269822R13, Page 29

30 Model SSL lower abinet and lower Parts (cont'd) lower, earing Support, and Motor on unit with up to a 5 HP Motor lower and earing on a unit with a 15 and 20 HP Motor (See OES ) ode Motor Mounting olts Motor Mounting ase Location of Optional ir Flow Switch Sensor, OE 339 Retaining lip, Star Washer Star Washer Replacement Filters/ lockoff Plates - Models SSL and SSL Filter 's - top of page 31 3/8 olt, Motor Mounting ase lockoff Plates Form P-S (03-18) PN269822R13, Page 30 lockoff Plates lockoff Plate Retaining lip, /16 olt, /8" olt 5/16" olt lower Triangular earing Mounting for SSL with a 7-1/2 or 10 HP Motor escription Left earing Support ssy Right earing Support ssy Pillowblock earing Sealmaster 1/16" (2) Grease Fitting /2-13 x 2" ap Screw GR-8 (4) /2-13 Nut GR-8 (4) /2 Lockwasher (4) /4-20 ap Screws (6) /4-20 Lock Nut (6) Filter rrangements for 1" or 2" isposable Filters (Options W2 and W7) 16 x x x x 30 lockoff Plates: (1) ; lockoff Plates lockoff Plates lockoff Plate 16 x x x x 25 lockoff Plates: (1) ; (4) OE Sensing Tube ssembly, lockoff Plates lockoff Plate lockoff Plate irflow IMPORTNT: Sensing tube must point into airflow. (4) SSL 400, 800, 1200; SSL 500, 600; SSL 800, 1600 (2 sets) SSL 1000, 1200 (2 sets) Filter rrangements for 1" or 2" isposable Pleated Filters (Options W10 and W11) SSL 700, 1050; SSL 1400 (2 sets) SSL 400, 800, 1200; SSL 500, 600; SSL 700, 1050; SSL 800, 1600 (2 sets) SSL 1000, 1200 (2 sets) SSL 1400 (2 sets) Filter rrangements for 1" or 2" Permanent Filters (Options W8 and W9) SSL 400, 800, 1200; SSL 800, 1600 (2 sets) 16 x x x x 32 lockoff Plates: (1) ; (4) x x x x 26 lockoff Plate: (1) SSL 500, 600; SSL 1000, 1200 (2 sets) 16 x x x x 25 lockoff Plates: (1) ; (4) x x x x 26 lockoff Plate: (1) SSL 700, 1050; SSL 1400 (2 sets) 1 (25mm) 10 (254mm) 16 x x x 30 lockoff Plates: (1) ; (4) x x x 32 lockoff Plate: (1) x x 26 lockoff Plate: (1)

31 NOTE: If replacing 1" filters, replace with locally supplied filters in the size and type listed. Quantities listed by size and arrangements illustrated on page 30 apply to both 1" and 2" filters. Filter Type Qty Size 2" Filter Qty Size 2" Filter Qty Size 2" Filter Model SSL 400, 800, 1200 SSL 500, 600 SSL 700, x x x isposable 1 16 x x x x x x x x x x x Permanent 8 12 x x x x x x x x x x Pleated 4 12 x x x x x x x x Model SSL 800, 1600 SSL 1000, 1200 SSL x x x isposable 2 16 x x x x x x x x x x x Permanent x x x x x x x x x x Pleated 8 12 x x x x x x x x ampers and ontrols - pplies to Models SE and SSL amper Motor and Linkage Outside ir ampers Return ir ampers ode amper and Frame ssembly for 100% Outside ir or Return ir ampers (includes one frame with damper blades only) Model Sizes 100, , , , , , , 800, ode escription (illustrations on page 28) omponents by Option R for "L" lower abinets (refer to wiring diagram for applicable motorized R Option) * 11* 12* 13* 14* 15 16* * Hand Quadrant # X X 352 Manual amper ontrol racket (replaces ) X X 353 Replacement Kit for other 2-position damper actuators including 66276, 97385, & labeled J/ M9206-G-2) X X X X 2-Position ctuator, M/H MS /U (effective 04/2012 on Model SSL) X X X 354 uxiliary End Switch only for M/H amper Motors, #Q , uxiliary Switch Kit (2 switches), M/H , Modulating amper Motor, #M (no end switch); Motor Support, X X X X X X X 356 Optional Modulating amper Motor, #M (Requires auxiliary switch kit, , ode 354.) X X X X X X X 357 Floating Modulating amper Motor, #M ; Motor Support, X 358 amper Rod, 1/4 x 12 inches long X X X X X 359 amper Rod, 1/4 x 13 inches long X X X X X X 360 amper Rod, 1/4 x 18 inches long X X X X 361 amper Rod, 1/4 x 17 inches long X X X X X X X X 362 amper Rod, ent (drawing, page 28) X 363 amper Rod rm X 364 amper rm, M/H # X X(2) X X(2) X(2) X(2) X(3) X(2) X(2) X(3) X(2) X(2) X(2) 365 all and Socket, M/H # X(2) X(2) X(2) X(4) X(4) X(4) X(4) X(4) X(4) X(4) X(4) X(4) X(4) 366 rank rm M/H # X X X X X X X X 367 amper rm Support Plate X 368 amper rm djustment Plate X X X X X X X 369 amper rm djustment Plate X 370 ir ontroller Support racket X X X X X X 371 Potentiometer, M/H #112894F X X X X 372 Mixed ir ontroller, M/H #T X X X 373 Outdoor ir ontroller, J/#19F X X X 374 Null Switch (pressure), wyer # X 375 (4-20ma) interface module for use with modulating damper motor, Honeywell Q7230, X Form P-S (03-18) PN269822R13, Page 31

32 ampers and ontrols (cont'd) - pplies to Models SE and SSL ode Hand Quadrant, ode Manual amper ontrol racket, ode amper Motor for 2-Position amper (open/closed), J/ M-9206-G-3, ode Kit, , includes motor , a mounting kit, and crankarm to field replace discontinued motors, 66276, 97385, and labeled Model M-9206-G-2. ode uxiliary End Switch, , M/H Q ode Modulating amper Motor used in Option R23, M/H #M , (with pressure null switch) ode Modulating amper Motor, M/H M less end switches, (replaces 53928) ode 357 (illustrated) - Modulating amper Motor, M/H M , , replacement requires auxiliary switch kit, , (ode 354) (replaces motor 96767) ode ent amper Rod 35 7 (178mm) 1/4 (6mm) 9-3/4 (248mm) ent amper Rod NOTE: rank rm ode 366 is used with motors , , and (used in currently manufactured units) Use rank rm (illustrated), M/H #7616R, with motors 53928, 87059, and amper Linkage Parts (see note left) ode Potentiometer, M/H F, ode Mixed ir ontroller, M/H T , Grommet lamp, ode Outside ir ontroller, J/ 19F-120, (replaces 16108) ode Pressure Null Switch, wyer #1640-0, Range.01" to.2" w.c., ode (4-20 ma) interface module for modulating damper motor, , M/H Q7230 Form P-S (03-18) PN269822R13, Page 32 Specifications & illustrations subject to change without notice and without incurring obligations. Nortek Global HV, LL ll rights reserved. ll marks are the property of their respective organizations. O Fallon, MO I Printed in U.S.. Form P-S (03-18) PN269822R13

All Sizes (155ºF), auto. yellow ADFH. All Sizes 50, 75, , (228ºF) , (306ºF) 150, , , 400

All Sizes (155ºF), auto. yellow ADFH. All Sizes 50, 75, , (228ºF) , (306ºF) 150, , , 400 orm P-N&LIMIT (10-15) Obsoletes orm P-N&LIMIT (03-15) IMPORTNT 1. lways include complete heater model and serial number so that any specification change can be considered for parts shipment. It can save

More information

Replacement Parts for Separated- Combustion Models SC, SCA, SCB, SCE, SSCBL, SSCDBL Parts Form P-SC (Version A)

Replacement Parts for Separated- Combustion Models SC, SCA, SCB, SCE, SSCBL, SSCDBL Parts Form P-SC (Version A) ITEMS THAT ARE HIGHLIGHTE ARE POPULAR ITEMS ITEMS WITH ONVERSATION ULE GIVE MORE INFORMATION IMPORTANT 1. Always include complete heater model and serial number so that any specification change can be

More information

Form P-RG/RP/RBL (03-18)

Form P-RG/RP/RBL (03-18) IMPORTANT 1. Always include complete heater model and serial number so that any specification change can be considered for parts shipment. It can save time and expense. 2. Specifications are subject to

More information

Replacement Parts For Model Series RG, RP, HRPD, RGB, RPB, RGBL, RPBL, RPDBL, PGBL, RBA, RBHA, and RBL (including prefixes "C", "H", and "HC")

Replacement Parts For Model Series RG, RP, HRPD, RGB, RPB, RGBL, RPBL, RPDBL, PGBL, RBA, RBHA, and RBL (including prefixes C, H, and HC) ITEMS THAT ARE HIGHLIGHTE ARE POPULAR ITEMS ITEMS WITH ONVERSATION ULE GIVE MORE INFORMATION IMPORTANT 1. Always include complete heater model and serial number so that any specification change can be

More information

No January, Eaton. Dual Self-Level Valve. Parts and Repair Information C D. Model XXX

No January, Eaton. Dual Self-Level Valve. Parts and Repair Information C D. Model XXX F Eaton No. 06-530 January, 000 Parts and Repair Information D Model 39055- Solenoid Valve Optional 4 34 Nm [5 lb-ft] 34 Nm [5 lb-ft] Solenoid Valve Optional 4 or or Unloading Spool Raise 4 3 8 6 7 7 8

More information

SECTION A-A TPA AND ALIGNMENT PLATE IN PRE-SEATED POSITION

SECTION A-A TPA AND ALIGNMENT PLATE IN PRE-SEATED POSITION THIS RWING IS UNPULISHE. OPYRIGHT Y TE ONNETIVITY RELESE FOR PULITION LL RIGHTS RESERVE. P LTR ESRIPTION TE WN PV REVISE PER EO00 MR JMS H REVISE PER EO00 PR JMS H QTY. REQUIRE INEX INEX INEX LIST OF PRTS

More information

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale)

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale) Version 1.0 Grade boundaries June 2018 exams GCSE Reformed (subjects which use the 9 to 1 grade scale) This document presents grade boundaries for the new reformed GCSEs which use the 9 to 1 grade scale.

More information

Replacement Parts for Z Series Model ZQYRA Ventilation Unit. Applies to: DANGER

Replacement Parts for Z Series Model ZQYRA Ventilation Unit. Applies to: DANGER IMPORTANT 1. Always include complete model and serial number so that any specification change can be considered for parts shipment. It can save time and expense. 2. Specifications are subject to change

More information

MPSH03CG-H05CG(D)

MPSH03CG-H05CG(D) H03-H05() Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-H03-H05()

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Package Gas-Electric - Commercial Table of Contents Model

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Package Air onditioners - ommercial Table of ontents Model

More information

INDIRECT FIRED FURNACE PARTS

INDIRECT FIRED FURNACE PARTS INDIRECT FIRED FURNACE PARTS 986964 Power Venter (Combustion Blower) Assembly ** S **Includes: Fan, Motor, Housing, etc. (Fasco) 986365 Igniter S 986725 Flame Sensor S 986982 H.S.I. Module 50E47-XXX w/

More information

refrigeration SHAKE #78RMT ELECTRO FREEZE SHAKE MACHINE BEATER SHAFT ASSEMBLY HEAD ASSEMBLY KEY PART # DESCRIPTION KEY PART # DESCRIPTION

refrigeration SHAKE #78RMT ELECTRO FREEZE SHAKE MACHINE BEATER SHAFT ASSEMBLY HEAD ASSEMBLY KEY PART # DESCRIPTION KEY PART # DESCRIPTION C ETER SHFT HED EF0 Scraper lade EF eater Shaft C EF eater Shaft Seal ssembly EF0 Head Only EF0 eater earing ushing EF0 Head O-Ring EF0 Lower Plunger O-Ring, pkg of EF00 Upper Plunger O-Ring, pkg of EF

More information

READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase.

READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase. SSEMLY MNUL uisinart Gourmet INFRRED 800 85-3058-4 (G52503) Propane 85-3059-2 (G52504) Natural Gas RED ND SVE MNUL FOR FUTURE REFERENE. ssemble your grill immediately. Missing or damaged parts should be

More information

ac-500 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven

ac-500 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven ac-00 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven REPLACEMENT PARTS LIST Effective june, 0 Superseding All Previous Parts Lists. The Company reserves the right to make

More information

B No. Notes COOLING CAPACITY 072 HEATING CAPACITY

B No. Notes COOLING CAPACITY 072 HEATING CAPACITY MOEL OOLING APAITY 10 13 HEAT EXHANGER, URNER/MANIFOL 45 Stk Main Limit - (ondenser ulkhead) E - Electric 47-23610-19 47-23610-19 45 Stk Main Limit - (ondenser ulkhead) X - NOX 47-23610-19 47-23610-19

More information

READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase.

READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase. SSEMLY MNUL uisinart Gourmet INFRRED 800 85-3058-4 (G52507) Propane 85-3059-2 (G52508) Natural Gas RED ND SVE MNUL FOR FUTURE REFERENE. ssemble your grill immediately. Missing or damaged parts should be

More information

Bussmann series IEC cylindrical fuses

Bussmann series IEC cylindrical fuses IE and ritish Standard fuses 5 ontents ussmann series IE cylindrical fuses Section page escription Fuses S Type P and fuses (N, S and PON) HR Form II lass fuses (GL) 3 HRI industrial ceramic body fuses

More information

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h Heating Input: 40,000 0,000 TU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 96% FUE ontents Nomenclature... ccessories... Product Specifications... imensions... 4 irflow ata... 5 Wiring iagrams...

More information

American Round Fuses - Form 101 range

American Round Fuses - Form 101 range Form 0 A5QS - 50 Vac A5QS- D007J 0 A5QS- E007J 0 A5QS- F0074J 0 4 A5QS4- G0075J 0 5 A5QS5- H007J 0 A5QS- J0077J 0 7 A5QS7- K0078J 0 8 A5QS8- L0079J 0 0 A5QS0- N008J 0 A5QS- P008J 0 5 A5QS5- Q008J 0 0 A5QS0-

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Oval shaped armature Encapsulated coil Push pin onded balanced poppet Return spring Manifold mounting Stacking plug-in

More information

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975 Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call

More information

Models WALL MOUNTED CONDENSING GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES DKVLT-075 DKVLT-150 DKVLT-050 DKVLT-200 DKVLT-299

Models WALL MOUNTED CONDENSING GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES DKVLT-075 DKVLT-150 DKVLT-050 DKVLT-200 DKVLT-299 Models DKVLT-050 DKVLT-075 DKVLT-100 DKVLT-150 DKVLT-200 DKVLT-299 WLL MOUNTED CONDENSING GS OILER PRTS, KITS & OPTIONL CCESSORIES Ordering Instructions Order Parts through your nearest supplier. When

More information

Genuine Metaris Gear Product Technical Catalog. Pumps & Components - MH Series Bearing & Bushing Style

Genuine Metaris Gear Product Technical Catalog. Pumps & Components - MH Series Bearing & Bushing Style Genuine Metaris Gear Product Technical Catalog Pumps & Components - MH Series Bearing & Bushing Style www.metaris.com MH365 Series Bushing Pump Features Metaris Bushing Pumps & Motors are available in

More information

Parts List, Technical Labels, & Wiring Diagrams

Parts List, Technical Labels, & Wiring Diagrams Parts List, Technical Labels, & Wiring Diagrams Small hassis Models PGAD4BK6 PGAD4DK6 PGAD0DK6 PGAD6DK6 PGAD6EK6 PGME4G0406 PGME4G0906 PGME0G0906 PGME6G0906 PGME6G56 Package Gas-Electric ombination Units

More information

Product Data 58GFA. Induced-Combustion Upflow Furnace Heating Inputs: 65,000 thru 150,000 Btuh. 78% AFUE With Continuous- Pilot Ignition

Product Data 58GFA. Induced-Combustion Upflow Furnace Heating Inputs: 65,000 thru 150,000 Btuh. 78% AFUE With Continuous- Pilot Ignition Product Data 58GF Induced-ombustion Upflow Furnace Heating Inputs: 65,000 thru 150,000 Btuh 78% FUE With ontinuous- Pilot Ignition arrier is the first manufacturer to provide a 78% nnnual Fuel Utilization

More information

2500/2700 Series Gas Convection Oven

2500/2700 Series Gas Convection Oven MARKET FORGE 2500/2700 Series Gas Convection Oven 2500/2700 Series Gas Convection Oven 2500 2700 2592 2792 Control Panel Assembly 1 99-4209 Control Panel Assembly Complete (Excluding Thermostat) 2 10-6307

More information

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators

3-Way Mixing and Sequencing Globe Valves, Flared (5/8 in. O.D.) with Electric, Hydraulic, and Pneumatic Actuators lectric, Hydraulic, and Pneumatic ctuators TL 1. Select Valve ody including P ode (Valve Size, v Rating, Port ode) or select Valve ssemly correct (refer to Tale 3 and Tale 3 also) less ctuator ode (XXX)

More information

SMP-2 Overload Relay. Product Selection Overview Feature SMP-1 SMP-2 SMP-3 TABLE OF CONTENTS. Description Page Description Page

SMP-2 Overload Relay. Product Selection Overview Feature SMP-1 SMP-2 SMP-3 TABLE OF CONTENTS. Description Page Description Page 3 ulletin 93 ulletin 93 SMP- Overload Relay SMP-3 Overload Relay SMP-2 Overload Relay Product Selection Overview Feature SMP- SMP-2 SMP-3 Self-Powered 3.2: djustment Range Phase Loss Protection Selectable

More information

AC-500 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST

AC-500 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST AC-00 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 9, 0 Superseding All Previous Parts Lists. The Company reserves the right to

More information

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975 Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call

More information

Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494

Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494 Technical ata isconnect Switch and ircuit reaker Mechanism Specifications ulletin Number 1494 Topic Page 1494U isconnect Switch Specifications 2 1494, 1494F, 1494G, 1494R, 1494V isconnect Switch Specifications

More information

36/60/160/260 L Series Gas Ranges

36/60/160/260 L Series Gas Ranges VULCAN L Series Gas Ranges 36/60/160/260 L Series Gas Ranges 34 THRU 41 1 5 51 52 26 42 THRU 49 55-56-57 2-3-4 33 31-32 25 29-30 27 15 PL-53065 14 13 12 28 24 23 22 21 20 19 18 16 17 52 11 10 9 8 7 6 632

More information

READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase.

READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase. SSEMLY MNUL uisinart Gourmet 600S 85-3078-6 (G41803) Propane 85-3079-4 (G41804) Natural Gas R ND SVE MNUL FOR FUTURE REFERENE. ssemble your grill immediately. Missing or damaged parts should be claimed

More information

Models WALL MOUNTED CONDENSING GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES DKVLT-075 DKVLT-150 DKVLT-050 DKVLT-200 DKVLT-299

Models WALL MOUNTED CONDENSING GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES DKVLT-075 DKVLT-150 DKVLT-050 DKVLT-200 DKVLT-299 Models DKVLT-050 DKVLT-075 DKVLT-100 DKVLT-150 DKVLT-200 DKVLT-299 WLL MOUNTED CONDENSING GS OILER PRTS, KITS & OPTIONL CCESSORIES ORDERING INSTRUCTIONS Order Parts through your nearest supplier. When

More information

CONDENSING GAS BOILER Models 075 & 100

CONDENSING GAS BOILER Models 075 & 100 ONDENSING GS OILER Models 075 & 100 PRTS, KITS & OPTIONL ESSORIES Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number from data plate

More information

COS-8G & COS-8GDS COMBI OVENS BCS-G STEAMER CNV-8G CONVECTION OVEN REPLACEMENT PARTS LIST

COS-8G & COS-8GDS COMBI OVENS BCS-G STEAMER CNV-8G CONVECTION OVEN REPLACEMENT PARTS LIST COS-G & COS-GDS COMBI OVENS BCS-G STEAMER CNV-G CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 0, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in

More information

Pump Panels Type 3R Enclosure

Pump Panels Type 3R Enclosure Type R Enclosure Product Family Overview June 6 Product escription The utler-hammer Pump ontrollers from Eaton s electrical business are combination starters with accessories and modifications designed

More information

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6 ATDR (Class CC TD) - 600Vac/300Vdc /4 ATDR/4 W2008J /2 ATDR/2 Q223068J 8/ ATDR8/ K20397J ATDR T2727J -/8 ATDR-/8 Y28820J -/4 ATDR-/4 J2830J -4/ ATDR-4/ K29337J -/2 ATDR-/2 Y2778J -6/ ATDR-6/ K29866J -8/

More information

Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 UBSSC-299 WALL MOUNTED GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 UBSSC-299 WALL MOUNTED GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES Models USSC-050 USSC-075 USSC-100 USSC-150 USSC-200 USSC-299 WLL MOUNTED GS OILER PRTS, KITS & OPTIONL CCESSORIES Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain

More information

FH Fan-Coil Units Low-Profile, Horizontal

FH Fan-Coil Units Low-Profile, Horizontal FH Fan-oil Units Low-Profile, Horizontal FH Fan-oil Units: Innovative design simplifies installation and service Owners HRI Standard 440-certifi cation ensures exacting performance. The FH fan-coil unit

More information

TECHNICAL GUIDE 80 AFUE MULTI-POSITION GAS FURNACES MODELS: G8C SERIES 4-POSITION MBH INPUT 3-POSITION 150 MBH INPUT DESCRIPTION WARRANTY

TECHNICAL GUIDE 80 AFUE MULTI-POSITION GAS FURNACES MODELS: G8C SERIES 4-POSITION MBH INPUT 3-POSITION 150 MBH INPUT DESCRIPTION WARRANTY TEHNIAL GUIE 80 AFUE MULTI-POSITION GAS FURNAES MOELS: G8 SERIES 4-POSITION 50-125 MH INPUT 3-POSITION 150 MH INPUT EFFIIENY RATING ERTIFIE ISO 9001 ertified Quality Management System ESRIPTION These compact

More information

REAR ARM & SUSPENSION

REAR ARM & SUSPENSION A REAR ARM & SUSPENSION JW-F0--00 REAR ARM COMP. JN-F-0-00 BUSH 900-00-00 909-00-00 NUT 90-000-00 BOLT 990-000-00 WASHER, SPRING 990-000-00 WASHER, PLATE JN-F-0-00 BUSH 9 9-0-00 0 90-00-00 NUT, SELF-LOCKING

More information

Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 UBSSC-299 WALL MOUNTED GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 UBSSC-299 WALL MOUNTED GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES Models USSC-050 USSC-075 USSC-100 USSC-150 USSC-200 USSC-299 WLL MOUNTED GS OILER PRTS, KITS & OPTIONL CCESSORIES Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain

More information

Drying Tumblers 110 Pound Capacity Refer to Page 3 for Model Numbers. Parts

Drying Tumblers 110 Pound Capacity Refer to Page 3 for Model Numbers. Parts Drying Tumblers 0 Pound Capacity Refer to Page 3 for Model Numbers Parts Part No. M444R April 000 Table of Contents Title Page Parts Ordering Information... Nameplate Location... Model Identification...

More information

E C N A A F -

E C N A A F - 33-52 NA ontactors & Starters 3-Phase agnetic Starters nclosed Freedom Line January 1 Vol. 2, Ref. No. [0068] Selection Table 33-102. NA Freedom Line nclosed ontrol ing System 33 esign Page N - NA 33-40

More information

12 SEER CENTRAL AIR CONDITIONING TON

12 SEER CENTRAL AIR CONDITIONING TON 12 SEER ENTRL IR ONDITIONING 1.5-5 TON QULITY FETURES Efficient scroll compressors Full metal louvered coil protection Quiet, top air discharge Galvanized steel cabinet with corrosion resistant powder

More information

GCS GCS

GCS GCS ENGINEERING T PKGE GS / ELETRI GS16 024 030 036 048 060 GS20 036 048 060 2 to 5 Ton (7.0 to 17.3 ) FUE 80% SEER up to 12.70 Net apacity 23,200 to 59,000 tuh (6.8 to 17.3 ) Input Heating apacity 50,000

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS GAS CONVECTION OVEN SG4 ML-126610 SG6 ML-126612 VULCAN-HART DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC 3600 NORTH POINT BLVD., BALTIMORE, MD 21222 FORM 45395 Rev. D (June 2017)

More information

Commercial & Industrial Ventilation Complete Line of Sustainable Products

Commercial & Industrial Ventilation Complete Line of Sustainable Products ommercia l Kitchen Ventilation ommercial & Industrial Ventilation omplete Line of Sustainable Products 919.88.4 800.334.956 919.88.504 (fax) www.captiveaire.com ontents entrifugal Upblast xhaust Fans N-F

More information

WALL MOUNTED GAS BOILER. Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 PARTS, KITS & OPTIONAL ACCESSORIES

WALL MOUNTED GAS BOILER. Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 PARTS, KITS & OPTIONAL ACCESSORIES Models USS-050 USS-075 USS-100 USS-150 USS-200 WLL MOUNTED GS OILER PRTS, KITS & OPTIONL ESSORIES H n ISO 9001-2008 ertified ompany 2201 Dwyer venue, Utica NY 13504-4729 web site: www.ecrinternational.com

More information

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View. Horizontal Low Profile oncealed with Plenum FU-RBHR-1.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041]

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS COMBI GAS OVENS MODELS ML-126836 ML-126837 ML-126838 VCG10H VCG10F VCG20H For additional information on Vulcan-Hart Company or to locate an authorized parts and service provider

More information

MT3270 & MT3255 SERIES CONVEYOR OVEN REPLACEMENT PARTS LIST

MT3270 & MT3255 SERIES CONVEYOR OVEN REPLACEMENT PARTS LIST APRIL 1999 MT3270 & MT3255 SERIES CONVEYOR OVEN REPLACEMENT PARTS LIST MT3255 A Division of G.S. Blodgett Corporation Superseding All Previous s Lists. The Company reserves the right to make substitution

More information

WAC Air Curtains Technical Guide

WAC Air Curtains Technical Guide TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2

More information

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac)

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac) MINITUR N MOL S IRUIT RKRS PowerPact ircuit reaker JL 3P ircuit reaker QL 2P 0 250 QL 3P 0 250 Tale.46: mpere - and Q-rame ircuit reakers lass 034, 0500 / Refer to atalogs: 034T0201, 0500T902 PowerPact

More information

WALL MOUNTED GAS BOILER. Models OLSSC-050 OLSSC-075 OLSSC-100 OLSSC-150 OLSSC-200 PARTS, KITS & OPTIONAL ACCESSORIES

WALL MOUNTED GAS BOILER. Models OLSSC-050 OLSSC-075 OLSSC-100 OLSSC-150 OLSSC-200 PARTS, KITS & OPTIONAL ACCESSORIES Models OLSS-050 OLSS-075 OLSS-100 OLSS-150 OLSS-200 WLL MOUNTED GS OILER PRTS, KITS & OPTIONL ESSORIES H n ISO 9001-2008 ertified ompany 2201 Dwyer venue, Utica NY 13504-4729 web site: www.ecrinternational.com

More information

JANDY HEATERS A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS

JANDY HEATERS A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS JANDY HEATERS Heaters H-58 A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS E-Z FIND CHART MARK V XE XE SERIES I SERIES I MILLIVOLT MILLIVOLT ELECTRONIC MILLIVOLT ELECTRONIC DM, DR EG ES, EC EPG EPS,

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,

More information

D F B. DFBH Rooftop Unit DFBV

D F B. DFBH Rooftop Unit DFBV SYSTEM, UAL LOWER MOEL H Rooftop Unit V ive Sizes H - Horizontal Configuration with ull Curb Cap ase and either Horizontal or Vertical (down) ischarge V - Vertical Configuration with Horizontal ischarge,

More information

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com MODEL: MCO-GS/GD-10 MU - CE UNITS Oven Manufactured Up To May 29, 2008 DESCRIPTION

More information

CUISINART C780sR Assembly Manual

CUISINART C780sR Assembly Manual TM Manual Revision #: 23102009 PD CUISINRT C780sR ssembly Manual 85-3032-4 (G51213) Propane 85-3033-2 (G51214) Natural Gas Limited 5-Year Warranty Read and save manual for future reference. ssemble your

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS OV210 GAS RACK OVENS ML-132113 ML-132115 OV210G-M1B OV210G-M2B A product of BAXTER MFG. CO., INC. 19220 STATE ROUTE 162 EAST, ORTING, WA 98360 FORM 43047 Rev. C (July 2017)

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

CENTRO Assembly Manual (G51206) Propane (G51209) Natural Gas LIMITED 5-YEAR WARRANTY

CENTRO Assembly Manual (G51206) Propane (G51209) Natural Gas LIMITED 5-YEAR WARRANTY CENTRO 3900 ssembly Manual -626- (G06) Propane -6-2 (G09) Natural Gas LIMITED -YER WRRNTY Read and save manual for future reference. ssemble your grill immediately. Missing or damaged parts should be claimed

More information

Raytherm Selection Guide

Raytherm Selection Guide The ot Water Management Experts SM Raytherm Selection uide Specifications for ommercial tmospheric: ydronic eating oilers Water eaters Specifications and Dimensions The Raytherm Selection uide is a ready-reference

More information

! WARNING: FIRE OR EXPLOSION HAZARD

! WARNING: FIRE OR EXPLOSION HAZARD Form I-SSL/RPL (Version E.3) Obsoletes I-SSL/RPL (Version E.2) INSTALLATION / OPERATION / MAINTENANE Applies to: Model SSL and Model RPL Packaged Systems USTOMER AGENY PRODUT PROESS QS ONVERGENT QUALITY

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Applies to: Models F, B, FE, and BE with spark pilot

Applies to: Models F, B, FE, and BE with spark pilot Form CP-F/B-GC (11/17) R8 Obsoletes Form CP-F/B-GC (Version A.2) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE with spark pilot NOTE: Units with standing (match - lit) pilots

More information

OEM Solutions & Custom Fans

OEM Solutions & Custom Fans OEM Solutions & ustom Fans E HIGH EFFIIENY IZE IMPELLERS XG & XP IZE XIL FNS (E) E (Electronically ommutated) external rotor motor 1-10 V or PWM motor control Excellent air and sound performance characteristics

More information

Designed for multi-position installation Heavy-duty stainless-steel tubular heat exchanger

Designed for multi-position installation Heavy-duty stainless-steel tubular heat exchanger M97M / 97M Modulating, Variable-Speed EM Gas Furnace Up to 98% FUE Heating Input: 60,000 0,000 TU/h ontents Nomenclature... Product Specifications... imensions... 4 irflow Specifications... 6 Wiring iagram...

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948

More information

SUMG-100. Burner Package & Components

SUMG-100. Burner Package & Components Burner Package & Components Burner Package & Components U_GO_PL_CONVECTION_SUMG100_1.pdf Burner Package & Components 1A 4521462 Burner Pack - DSI MCO - 60K - Natural Gas 1 [1] 1A CK4521468 Burner Pack

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS GAS CVECTI OVENS ML-43856 ML-43859 ML-43853 ML-114731 ML-114732 HGC40 HGC40D DGC1 HGC60 HGC60D A product of HOBART CORPORATI 701 RIDGE AVENUE TROY, OHIO 45374-0001 FORM 33761

More information

CUISINART C790SR Assembly Manual

CUISINART C790SR Assembly Manual TM Manual Revision #: 17052011 PD CUISINRT C790SR ssembly Manual 85-3032-4 (G51217) Propane 85-3033-2 (G51218) Natural Gas LIMITED 5-YER WRRNTY Read and save manual for future reference. ssemble your grill

More information

U L OIL-FIRED FURNACES. Stellar MBH OUTPUT 80 AFUE DESCRIPTION FEATURES MULTI-POSITION MODELS - P1FM DOWNFLOW/HORIZONTAL MODELS - P1FH

U L OIL-FIRED FURNACES. Stellar MBH OUTPUT 80 AFUE DESCRIPTION FEATURES MULTI-POSITION MODELS - P1FM DOWNFLOW/HORIZONTAL MODELS - P1FH 660.06-TGY (795) MULTI-POSITION S - PFM Stellar 2000 OIL-FIRED FURNES 55-200 MH OUTPUT 80 FUE U L DOWN/HORIZONTL S - PFH DESRIPTION These oil-fired furnaces are compact, decorator-styled warm air heating

More information

IMPORTANT: When ordering parts, please provide the model, gas type and serial number of the oven The identification plate is located on the back of th

IMPORTANT: When ordering parts, please provide the model, gas type and serial number of the oven The identification plate is located on the back of th MG3270 & MG-32 CONVEYOR OVEN REPLACEMENT PARTS LIST EFFECTIVE SEPTEMBER 13, 2001 BLODGETT OVEN COMPANY, 50 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 860-3700 (800) 331-5842 Fax: (802)

More information

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards -P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit

More information

Definite Purpose Control. Product Focus

Definite Purpose Control. Product Focus Product Focus Innovation in Eaton s utler-hammer efinite Purpose (P) ontactors are designed to improve control of refrigeration, air conditioning, ventilation and resistance heating applications. The

More information

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996 Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call

More information

WIRING DIAGRAMS 0 CONNECTOR HOUSING AREA WIRING DIAGRAM LEGEND WIRE COLORS WARNING. Wiring diagrams can be found at the end of this subsection.

WIRING DIAGRAMS 0 CONNECTOR HOUSING AREA WIRING DIAGRAM LEGEND WIRE COLORS WARNING. Wiring diagrams can be found at the end of this subsection. Section Subsection 0 WIRING IGRMS (WIRING IGRMS) WIRING IGRMS 0 Wiring diagrams can be found at the end of this subsection. WIRING IGRM LEGEN WRNING Ensure all terminals are properly crimped on the wires

More information

SECTION 8. PARTS INFORMATION

SECTION 8. PARTS INFORMATION SECTION 8. PARTS INFORMATION 8-1. INTRODUCTION This section lists the replaceable parts of the Henny Penny Model LVG fryer. 8-2. GENUINE PARTS Use only genuine Henny Penny parts in your fryer. Using a

More information

Model PCD Indirect-Fired, Vertical/Horizontal, Indoor/Outdoor, Packaged, Makeup Air Heating and Air Conditioning System

Model PCD Indirect-Fired, Vertical/Horizontal, Indoor/Outdoor, Packaged, Makeup Air Heating and Air Conditioning System Model P Indirect-Fired, Vertical/Horizontal, Indoor/Outdoor, Packaged, Makeup Heating and onditioning System USTOMR QS NY ONVRNT QULITY SYSTM PROUT PROSS STRT-UP WRRNTY ontents MOLS P, HP SRIPTION... 2

More information

Leadership driven by innovation

Leadership driven by innovation s Leadership driven by innovation Our innovations are your solutions for enhanced productivity LV Switchgear Motor Control Products Maximum etail Price w.e.f. 23 rd September, 203 Index Contents 2 Page

More information

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF

More information

THIS MANUAL CONTAINS THE ILLUSTRATED PARTS LIST FOR MODELS: SZL36-18FR

THIS MANUAL CONTAINS THE ILLUSTRATED PARTS LIST FOR MODELS: SZL36-18FR IPL 0 0 ILLUSTRTED PRTS MNUL Model SZL Liberty Z THIS MNUL ONTINS THE ILLUSTRTED PRTS LIST FOR MODELS: SZL-FR with a serial number of M0000 to M SZL-FR with a serial number of M000000 to M0 SZL-FR with

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15

More information

READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase.

READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase. SSEMLY MNUL Cuisinart Gourmet 700 85-3056-8 (G52505) Propane 85-3057-6 (G52506) Natural Gas RED ND SVE MNUL FOR FUTURE REFERENCE. ssemble your grill immediately. Missing or damaged parts should be claimed

More information

WALL MOUNTED GAS BOILER. Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 UBSSC-299 PARTS, KITS & OPTIONAL ACCESSORIES

WALL MOUNTED GAS BOILER. Models UBSSC-050 UBSSC-075 UBSSC-100 UBSSC-150 UBSSC-200 UBSSC-299 PARTS, KITS & OPTIONAL ACCESSORIES Models USSC-050 USSC-075 USSC-100 USSC-150 USSC-200 USSC-299 WLL MOUNTED GS OILER PRTS, KITS & OPTIONL CCESSORIES Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain

More information

Midwest Electric Products. AC Disconnects

Midwest Electric Products. AC Disconnects Midwest Electric Products isconnects Midwest Electric Products pplication Information rticle 440 of the National Electrical ode applies to electric motor-driven air conditioning and refrigerating equipment

More information

BC. Materials. Working temperature (Seals) Sectors: Industrial, Agricultural

BC. Materials. Working temperature (Seals) Sectors: Industrial, Agricultural 1 SERI ISO-A Manufactured according ISO 7241-A norm, size meets also ISO 5675 requirements. Poppet Valve or Ball closing system. BSP, NPTF, SAE/ORB threads. Others available upon request. Materials Body:

More information

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h DP14HM ommercial ooling apacity: 34,400-58,000 BTU/h Heating apacity: 33,00-57,000 BTU/h 3-5 TON THREE-PHASE PAKAGED HEAT MPS 14 SEER ontents Nomenclature... Product Specifications...3 Expanded ooling

More information

Bulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)

Bulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C) Installation Instructions ulletin 1494F, 60, Fixed-epth isconnect Switch (at 1494F-N30; 1494F-N60; 1494F-N100; Series ) WRNING: To prevent electrical shock, disconnect from power source before installing

More information

DFG-50 GAS CONVECTION OVEN REPLACEMENT PARTS LIST

DFG-50 GAS CONVECTION OVEN REPLACEMENT PARTS LIST DFG-50 GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 19, 2012 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are

More information

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996 Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Automated Steering Kit Installation Guide

Automated Steering Kit Installation Guide Fits Buhler Versatile and New Holland Tractor Models: 2270 9280 9282 9184 2290 9480 9482 9384 2310 9680 9682 9484 2335 9880 9882 9684 2360 9884 2375 2425 Read and Follow Safety Messages Automated Steering

More information

Designed for multi-position installation Heavy-duty aluminized-steel tubular heat exchanger

Designed for multi-position installation Heavy-duty aluminized-steel tubular heat exchanger / GVM97 Heating Input: 60,000 0,000 TU/h Modulating, Variable-Speed EM Gas Furnace Up to 98% FUE ontents Nomenclature... Product Specifications... imensions... 4 irflow Specifications... 6 Wiring iagram...

More information

CONTENTS ALTERNATE FOR SUN ROOF C2 ALTERNATE FOR WINDSHIELD BATTERY CHARGER BODY 2

CONTENTS ALTERNATE FOR SUN ROOF C2 ALTERNATE FOR WINDSHIELD BATTERY CHARGER BODY 2 SUN ROOF C2 2 FITTING ELECTRICAL 1 0-11 A1 REAR ARM SUSPENSION 1 JW2-F2110-00-00 REAR ARM COMP.......... 1 2 JN6-F2123-10-00 BUSH 1.................. 1 3 90105-13864-00 BOLT, FLANGE............ 1 4 90179-13878-00

More information

MCO HALF SIZE MODELS (electric) MCO-E-5 FROM 2000 AND UP

MCO HALF SIZE MODELS (electric) MCO-E-5 FROM 2000 AND UP MCO HALF SIZE MODELS (electric) MCO-E-5 FROM 2000 AND UP Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com FORM # MCO E5 Elec (Rev

More information