INDIRECT FIRED FURNACE PARTS
|
|
- Avis Harmon
- 6 years ago
- Views:
Transcription
1 INDIRECT FIRED FURNACE PARTS Power Venter (Combustion Blower) Assembly ** S **Includes: Fan, Motor, Housing, etc. (Fasco) Igniter S Flame Sensor S H.S.I. Module 50E47-XXX w/ "F" Chip for IDF & Modulating Burners S H.S.I. Wiring Harness F115 L Fan Limit Switch - (60T12) S High Limit Switch - (60T11)** S **Please Order 2 Per Furnace Duct Stat - 2-Stage L Duct Stat - Modulating L Small Heat Exchanger 409 Stainless Steel** S ** For Unit Models 175, 200, Large Heat Exchanger 409 Stainless Steel** S ** For Unit Models 300, 350, Furnace Burner Tube** L **Please Order 23 Tubes for Large Furnace, 13 Tubes for Small Furnace Heat Exchanger Baffle Plate** L **Please Order 23 Tubes for Large Furnace, 13 Tubes for Small Furnace Insulated Collection Box Assembly; (ships fully assembled)** L ** For Unit Models 175, 200, Insulated Collection Box Assembly; (ships fully assembled)** L ** For Unit Models 300, 350, Small Burner Assembly ** L Large Burner Assembly ** L ** Burner Assembly Does Not Include Gas Pipe Manifold or Orifices Small Gas Pipe Manifold ** L Large Gas Pipe Manifold ** L ** Gas Pipe Manifold Does Not Include Orifices #47 1/8 NPT Orifice L #48 1/8 NPT Orifice L #49 1/8 NPT Orifice L #50 1/8 NPT Orifice L #51 1/8 NPT Orifice L #52 1/8 NPT Orifice L #53 1/8 NPT Orifice L #56 1/8 NPT Orifice L #57 1/8 NPT Orifice L #58 1/8 NPT Orifice L #59 1/8 NPT Orifice L Page 1 Effective Sep 15, 2014
2 INDIRECT FIRED FURNACE PARTS #60 1/8 NPT Orifice L #61 1/8 NPT Orifice L #62 1/8 NPT Orifice L #63 1/8 NPT Orifice L Stage Natural Gas Valve S Stage Natural or Liquid Propane Gas Valve** S ** Includes Liquid Propane Conversion Kit Stage Liquid Propane Gas Valve S Stage Liquid Propane Gas Valve ****Please Use O Modulating Natural Gas Valve** L ** For Unit Models 175, 200, Modulating Natural Gas Valve** L ** For Unit Models 300,350, Modulating Liquid Propane Gas Valve** L ** For Unit Models 175, 200, Modulating Liquid Propane Gas Valve** L ** For Unit Models 300,350, Combustion Duct Access Door Panel O Burner Access Door Panel O Furnace Control Access Door Panel O Power Venter Rain Hood (Outdoor Kit) L Adapter Flue for Power Venter - Square to 6" Round Adapter (Indoor Kit) L Combustion Blower Assembly (includes Power Venter) S Combustion Blower Assembly (includes Power Venter) S Combustion Blower Assembly (includes Power Venter) S Combustion Blower Assembly (includes Power Venter) S Combustion Blower Assembly (includes Power Venter) S Combustion Blower Assembly (includes Power Venter) S Combustion Blower Plate for 175 (2-1/2") O Combustion Blower Plate for 200 (2-11/16") O Combustion Blower Plate for 225 ( 2-7/8" ) O Combustion Blower Plate for 300 (3-5/16") O Combustion Blower Plate for 350 (3-5/8') O Combustion Blower Plate for 400 (3-7/8") O Combustion Blower Boot (All Sizes) O Combustion Blower Top (All Sizes) O CSL Silicone 503 Hi-Temp Red Silicone Sealant O Page 2 Effective Sep 15, 2014
3 BLOWER ASSEMBLY PARTS (ALL UNITS) Blower Assembly: 15x15x1" Bore** S **Includes: Blower Wheel, Shaft and (2) Bearing Brackets Blower Assembly: 18x18x1" Bore** S **Includes: Blower Wheel, Shaft and (2) Bearing Brackets Blower Assembly: 18x18x1-3/16" Bore** L **Includes: Blower Wheel, Shaft and (2) Bearing Brackets SC3A (DLB-2) Blower Assembly: 2-15x15x1" Bore - 3 to 5 HP Motor L SC3B (DLB-2) Blower Assembly: 2-15x15x1-11/16" Bore HP+ Motor N SC4A (DLB-925) Blower Assembly: 25x25x1-7/16" Bore N SC4B (DLB-925) Blower Assembly: 25x25x1-11/16" Bore N Blower Wheel: 15"x15"x1" S Blower Wheel: 18x18x1" S Blower Wheel: 18x18x1-3/16" N Shaft: 15x15x1" - Delhi S Shaft: 18x18x1" - Delhi S Shaft: 18x18x1-3/16" - Delhi N Shaft: 15x15x1" - Lau O Shaft: 18x18x1" - Lau O Shaft: Dual Blower, 1"X59" - Old Style - Delhi O Shaft: Dual Blower,1-11/16"x59" - New Style - Delhi O K15151 Kit: 1 Bearing Bracket w/ 1 Bearing - 15"x15"x1" Bore - Delhi** S ** Please order 2 Kits per blower K18181 Kit: 1 Bearing Bracket w/ 1 Bearing - 18"x18"x1" Bore- Delhi** S ** Please order 2 Kits per blower K Kit: 1 Bearing Bracket w/ 1 Bearing - 18"x18"x1-3/16" Bore - Delhi** L ** Please order 2 Kits per blower Bearing Bracket - 15"x15"x1" Bore - Delhi (See Kit above) O Bearing Bracket - 18x18"x1" Bore - Delhi (See Kit above) O Bearing Bracket - 18x18"x1-3/16" Bore - Delhi (See Kit above) O Bearing: 1 Bore (OD 2-1/4") - Delhi (See Kit above) O Bearing: 1 3/16" Bore (OD 2-1/4" ) - Delhi (See Kit above) O Bearing Bracket: 15"x15"x1" Bore - Lau O Bearing Bracket: 18x18"x1" Bore - Lau O Bearing: 1 Bore (OD 2-9/16") - Lau (SKF Model# R-1-FM) O Bearing: DLB-2 Dual Blower (ID 1-11/16") - New Style O Blower Assembly: ADF9-9x9 (Direct Fired) O Blower Assembly: ADF15-15x15 (Direct Fired) O Blower Assembly: ADF20-20x20 (Direct Fired) O Bearing: ADF9 (SKF Model# YAR F) (Direct Fired) O Bearing: ADF15 (SKF Model# YAR-103-2F) (Direct Fired) O Bearing: ADF20 (SKF Model# YAR-107-2F) (Direct Fired) O Page 3 Effective Sep 15, 2014
4 EVAP COOLER PARTS & ACCESSORIES O7400 Galvanized Pad Frame (Inlet Louver) Assembly** L **Includes CoolPad Media for NON-Evap Units O7405 Galvanized Pad Frame (Inlet Louver) Assembly** S ** Includes 2" CelDEK Media for EVAP Units O Stainless Steel Pad Frame (Inlet Louver) Assembly** L **Includes CoolPad Media for NON-Evap Units O Stainless Steel Pad Frame (Inlet Louver) Assembly** L **Includes 2" CelDEK Media for EVAP Units Stainless Steel Evap Blower Bottom (SE1, SE2 Evap Blowers ) L Galvanized Motor Base (IDF Units) L Galvanized Motor Base for Dual Blower (IDF Units) L CoolPad Replacement Media 36" x 34" (SC1/SC2)** S **3 Media Pads Required Per Unit, One Pad Per Door CoolPad Replacement Media 36" x 20 Feet (Whole Roll) (SC1/SC2) O O5915 2" Rigid CelDEK Media Set (SE1/SE2 Evap Units)** S **3 Sets Required Per Unit, One Set Per Door O5930 CEV6000 CelDEK Media Set S O5931 CEV6000 CelDEK Media Set (For Serial # A8006 and after) S O5940 CEV6000 Fiberglass Media Set L CEV x 20 x 2 Power Guard Filter (6 required) L CEV6000 Inlet Louver L O5935 CEV12000 CelDEK Media Set L O5945 CEV12000 Fiberglass Media Set L CEV x 18 x 2 Power Guard Filter (9 required) L CEV12000 Inlet Louver L Sump Pump 115V (SE1, SE2, CEV6000) S Sump Pump 115V (CEV12000) S O A Automatic Fill & Drain Kit** L **Includes 2 & 3 Way Valve w/solenoids, Auto-Freeze T'stat O Manual Fill & Drain Kit** L **Includes 2 Way & 3 Way Valve w/ Solenoids SE Evap Bag Assy** L **Float , Overflow , Drain , Bleed , Bleed Adj CEV Evap Bag Assembly L SE Evap Drain Assembly (SE1/SE2) L Float Assembly S ¾ Overflow (Stand Pipe) Assembly L Standard Evap Drain Assembly L Rubberized Undercoating Spray (for EVAP. Bottom Pan) O Page 4 Effective Sep 15, 2014
5 INDIRECT FIRED ELECTRICAL PARTS, THERMOSTATS, & LOOSE OPTIONS KVA Transformer 208/3 TO 120/1 L KVA Transformer 230/460/3 TO 120/1 L KVA Transformer 208/3 TO 120/1 (Dual Furnace) L KVA Transformer 230/460/3 TO 120/1 (Dual Furnace) L Contactor 1210 / 24 Volt ** L Contactor 2510 / 24 Volt ** L Contactor 24 Volt - 2 Speed O Contactor 24 Volt- 2 Speed O Mechanical Interlock DPBF 1210 / 2510 Contactors O Overload ( A) ** L Overload (3-5A) ** L Overload (6-10A) ** L Overload (9-15A) ** L Overload (14-23A) ** L Overload (2-3.3A) ** L Overload ( A) ** L Overload (20-30A) ** L Overload (28-42A) ** L Overload (42-50A) ** L Customer must provide Unit Serial # and/or Motor FLA to properly size Contactor/Overloa Auxiliary Contact L Fuse (10 Amp) L ALL ARES Relays -Cool, Heat, Damper, Fire Interlock, etc. (See note below) L B ALL ARES Relays -Cool, Heat, Damper, Fire Interlock (1 Required When Ordering ) L Time Delay (Ignition) L Time Delay (Freeze Thermostat) TS V L Control Transformer 75VA 120/208/240/460-24V L Air Proving Switch (Indoor Units) L A1010U Amplifier for Single, Dual or Triple Modulating Furnace L A1011B Amplifier for Dual or Triple Modulating Furnace O SC11 (A200) Signal Conditioner (4-20 MA or 0-10V Signal) L Bridge Rectifier (Modulating Gas Only) L Room Sensing Thermostat for Modulating Gas, T120 Selectrastat L Remote Temperature Selector - Modulating (TD121) L Room Override Thermostat - Modulating (T115 ) L O5280 Room Override Thermostat - 2 Stage L Room Override Thermostat - Direct Fired Units Only O O2905 Freeze Thermostat L Page 5 Effective Sep 15, 2014
6 INDIRECT FIRED ELECTRICAL PARTS, THERMOSTATS, & LOOSE OPTIONS O2905 Mild Weather Lock Out (Ambient) Thermostat L O2905 Cool Enable Thermostat L Day Time Clock 120V, V Input Signal O Clogged Filter Indicator (CF-1) L Belimo 2 Position Inlet Damper Actuator O Belimo Modulating Inlet Damper Actuator O Potentiometer SGA24 (for Modulating Damper) O Position Discharge Damper Actuator O O5240 Perforated Ceiling Outlet Box - Stainless Steel (951M1) O Page 6 Effective Sep 15, 2014
7 PUSH BUTTON REMOTE CONTROL PANELS R1129 Off / Cool / Vent / Heat 24 Volt S R1130 Off / Cool / Vent / Heat / 2 Speed 24 Volt O R1135 Off / Cool / Vent / Heat / R/A 24 Volt L R1140 Off / Cool / Vent / Heat / Modulating 24 Volt L R1145 Off / Cool / Vent / Heat / R/A / Modulating L R1150 Off / Cool / Vent / Heat / 2 Speed / Modulating O R1155 Off / Cool / Vent / Heat / R/A / 2 Speed O R1160 Off / Cool / Vent / Heat / R/A / 2 Speed / Modulating O R1165 Off / Vent / Heat 24 Volt L R1170 Off / Vent / Heat / 2 Speed O R1175 Off / Vent / Heat / R/A L R1180 Off / Vent / Heat / Modulating L R1185 Off / Vent / Heat / R/A / 2 Speed O R1190 Off / Vent / Heat / R/A / Modulating L R1195 Off / Vent / Heat / Modulating / 2 Speed O R1200 Off / Vent / Heat / R/A / Modulating / 2 Speed O R1514 Off / Vent / Cool 24 Volt L R1515 Off / Vent / Cool 115 Volt L R1516 Off / Vent / Cool 220 Volt L R1511 Off / Vent 24 Volt L R1512 Off / Vent 115 Volt L R1513 Off / Vent 220 Volt L Push Buttons for Remote (Set of 4) L Page 7 Effective Sep 15, 2014
8 MOTORS (CONTACT FACTORY FOR AVAILABILITY) (ALL UNITS) MOTOR: ODP; 1/2 HP, /460, 3 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: ODP; 3/4 HP, /460, 3 PH, 1 SPEED- STANDARD EFFICIENCY N MOTOR: ODP; 1 HP, /460, 3 PH, 1 SPEED- STANDARD EFFICIENCY N MOTOR: ODP; 1-1/2 HP, /460, 3 PH, 1 SPEED- STANDARD EFFICIENCY N P MOTOR: ODP; 2 HP, /460, 3 PH 1 SPEED- PREMIUM EFFICIENCY N P MOTOR: ODP; 3 HP, /460, 3 PH, 1 SPEED - PREMIUM EFFICIENCY N P MOTOR: ODP; 5 HP, /460, 3 PH, 1 SPEED - PREMIUM EFFICIENCY N P MOTOR: ODP; 7-1/2 HP, /460, 3 PH, 1 SPEED - PREMIUM EFFICIENCY N P MOTOR: ODP; 10 HP, /460, 3 PH, 1 SPEED - PREMIUM EFFICIENCY N P MOTOR: ODP; 15 HP, /460, 3 PH, 1 SPEED - PREMIUM EFFICIENCY N P MOTOR: ODP; 20 HP, /460, 3 PH, 1 SPEED - PREMIUM EFFICIENCY N MOTOR: ODP; 1/2 HP, 115/ , 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: ODP; 3/4 HP, 115/ , 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: ODP; 1 HP, 115/ , 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: ODP; 1-1/2 HP, 115/ , 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: ODP; 2 HP, 115/ , 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: ODP; 3 HP, 115/ , 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: ODP; 5 HP, 115/ , 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: ODP; 7-1/2 HP, V, 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: ODP; 10 HP, 230V, 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 1/2 HP, /460, 3 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 3/4 HP, /460, 3 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 1 HP, /460, 3 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 1-1/2 HP, /460, 3 PH, 1 SPEED -STANDARD EFFICIENCY N MOTOR: TEFC; 2 HP, /460, 3 PH, 1 SPEED - STANDARD EFFICIENCY N P MOTOR: TEFC; 3 HP, /460, 3 PH, 1 SPEED - PREMIUM EFFICIENCY N P MOTOR: TEFC; 5 HP, /460, 3 PH, 1 SPEED - PREMIUM EFFICIENCY N P MOTOR: TEFC; 7-1/2 HP, /460, 3 PH, 1 SPEED - PREMIUM EFFICIENCY N MOTOR: TEFC; 1/2 HP, 115/230, 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 3/4 HP, 115/230, 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 1 HP, 115/230, 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 1-1/2 HP, 115/230, 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 2 HP, 115/230, 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 3 HP, 115/230, 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 5 HP, 230, 1 PH, 1 SPEED - STANDARD EFFICIENCY N MOTOR: TEFC; 7 HP, 230, 1 PH, 1 SPEED - STANDARD EFFICIENCY N **CONTACT FACTORY FOR PRICING & AVAILABILITY ON ALL MOTORS NOT LISTED** Page 8 Effective Sep 15, 2014
9 PULLEYS & BELTS (ALL UNITS) Pulley: 9 x 1 Bore S Pulley: 9 x 1 Bore 2 Groove L Pulley: 11 x 1 Bore S Pulley: 11 x 1 Bore 2 Groove L Pulley: 14 x 1 Bore S Pulley: 14 x 1 Bore 2 Groove L Pulley: 6 x 1-3/16 Bore **Bushing not included. Order separately. L Pulley: 6 x 1-3/16 Bore 2 Groove L Pulley: 9 x 1-3/16 Bore L Pulley: 9 x 1-3/16 Bore 2 Groove L Pulley: 11 x 1-3/16 Bore L Pulley: 11 x 1-3/16 Bore 2 Groove L Pulley: 14 x 1-3/16 Bore L Pulley: 14 x 1-3/16 Bore 2 Groove L Bushing: 1 L Bushing: 1-3/16" L Sheave: 3-1/4 x 5/8 Bore L Sheave: 3-3/4 x 5/8 Bore L Sheave: 3-3/4 x 7/8 Bore L Sheave: 4-1/4 x 5/8 Bore L Sheave: 4-1/4 x 7/8 Bore L Sheave: 4-1/4 x 1-1/8 Bore L Sheave: 4-3/4 x 5/8 Bore L Sheave: 4-3/4 x 7/8 Bore L Sheave: 4-3/4 x 1-1/8 Bore L Sheave: 6" x 1-1/8" Bore L Sheave: 6 x 1-1/8 Bore 2 Groove L Sheave: 6 x 1-3/8 Bore 2 Groove L Sheave: 6" x 1-5/8" Bore 2 Groove L Vee Belt A-58 L Vee Belt A-61 L Vee Belt A-62 L Vee Belt A-63 L Vee Belt A-64 L Vee Belt A-67 L Vee Belt A-68 L Vee Belt A-65 L Vee Belt A-66 L Vee Belt A-69 L Vee Belt A-70 L Vee Belt A-71 L Page 9 Effective Sep 15, 2014
ARES PARTS ORDERING INFORMATION
ARE PART ORDERIG IFORMATIO A. ORDERIG: (ALL HIPMET F.O.B. Anthony, M) For prompt and accurate handling of your parts order, always include the following information. hipment of parts may be delayed without
More informationTGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.
TGIF-3 Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of
More informationMODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER
L (Housing Arr. H) 4" 6" A=Blower B=Filter C=Intake Downturn Plenum W Intake damper (Optional) H Birdscreen " Curb Cap D Electrical connection H Housing V-bank filters intake hood Gas connection E Lifting
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL MOUNTED GAS/ELECTRIC Models: WG-A WG-B WG-C W0G-A W0G-B W0G-C W6G-A W6G-B W6G-C Contents Description Page Cabinet Components Exploded View... Usage List... Usage List... Functional
More informationDirect Gas-Fired Heating
Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL MOUNTED GAS/ELECTRIC WG-A WG-B WG-C Models: W8G-A W8G-B W8G-C W60G-A W60G-B W60G-C Contents Description Page Cabinet Components Exploded View... Usage List... Usage List...
More informationQuantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP)
Mark: ASP 1 Model: ASP - 52.00 - S ASP Air Curtain Supply (ASP) Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP) 52 14 10 740 0.13 Supply Collar
More informationSECTION 6 PARTS LIST
SECTION FIGURE NO. DESCRIPTION PAGE NO. -1 - - -4-5 - - -8-9 Oven Panels, Window and Legs Exploded Drawing Air Finger Exploded Drawing Control Panel Exploded Drawing Blower and Shroud Exploded Drawing
More informationRAYPAK ILLUSTRATED PARTS LIST
RAYPAK ILLUSTRATED PARTS LIST The parts listed are for standard equipment for this model type. Raypak reserves the right to substitute, delete or change any part without notification. The addition of options
More informationContents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506
REPLACEMENT PARTS MANUAL WALL MOUNTED GAS/ELECTRIC MODELS: W2G-A W2G-B W2G-C W8G-A W8G-B W8G-C W60G-A W60G-B W60G-C General Notes Contents Revised and/or additional pages may be issued from time to time.
More informationPredator Model Number Nomenclature
DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20
More informationNON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP
Item :A Prep Room NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG-200830-C-PREP Booth Working Dimensions: 20'0 Wide x 8'0 High x 30'0 Working Depth Approx. Booth Overall Dimensions: 20'4 Wide x 8'10
More informationHVAC INDOOR MAKE-UP AIR HANDLERS
GIAC-8 HVAC INDOOR MAKE-UP AIR HANDLERS Application Manual PACKAGED INDOOR ARRANGEMENTS FOR MAKE-UP AIR, HEATING AND COOLING Contents 2 PAGE GENERAL INFORMATION 2, 3 MODEL NUMBER DESCRIPTION 4 INDOOR DUCT
More informationCOMMERCIAL and POOL MODELS: 302C THROUGH 902C
COMMERCIAL and POOL MODELS: 302C THROUGH 902C CATALOG NO. 9300.753 Effective: 12-01-17 Replaces: 12-01-16 RAYPAK REPLACEMENT PARTS MODEL SIZES: 302C, 402C, 502C, 652C, 752C & 902C MODEL TYPES: HI DELTA
More informationXIII. Repair Parts 106
XIII. Repair Parts All Alpine Repair Parts may be obtained through your local authorized U.S. Boiler Company representatives or outlets. Should you require assistance in locating a U.S. Boiler Company
More informationContents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506
REPLACEMENT PARTS MANUAL WALL MOUNTED GAS/ELECTRIC MODELS: WG2-A WG2-B WG2-C WG82-A WG82-B WG8-C WG602-A WG602-B WG60-C General Notes Contents Revised and/or additional pages may be issued from time to
More informationMcQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996
Replacement Parts List No. 779200600 Revision B 07/2007 McQuay Climate Control Singer Rooftop Unit ER, R 160 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS MINI RACK OVEN OV310G ML-132515 A product of BAXTER MFG. CO., INC. 19220 STATE ROUTE 162 EAST, ORTING, WA 98360 FORM 43242 (October 2011) Table of Contents 3 ADVANCED CONTROL
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS OV210 GAS RACK OVENS ML-132113 ML-132115 OV210G-M1B OV210G-M2B A product of BAXTER MFG. CO., INC. 19220 STATE ROUTE 162 EAST, ORTING, WA 98360 FORM 43047 Rev. C (July 2017)
More informationELECTRICAL 2 6 BOARD, CONTROL CAP, RUN, 50.0/5.0MFD [1RC]
D1NP-*048 (13 SEER) SINGLE PACKAGE GAS HEAT REPLACEMENT PARTS Supersedes: Nothing e 035-18923-001 Rev. A (0502) 1 of 16 38 5 37 36 35 63 61 72 51 54 65 23 72 59 1 13 47 31 68 2 3 69 46 29 30 14 4 32 33
More informationMcQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002
Replacement Parts List No. 779200800 Revision C 04/2002 McQuay Climate Control Singer Rooftop Unit ER, R 250 Vintage C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationReplacement Parts List
Replacement Parts List Single Package Cool/Heat 15 to 16.5 SEER D1NX024 D1NX024N036* COMPRESSOR Compressor, ZPS20K4E-PFV-230 S1-015-03668-004 - 1 - CONDENSER FAN MOTOR & COMPONENTS Roof, Unit S1-073-19411-001
More informationMcQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996
Replacement s List No. 055236800 Revision C 11/2016 McQuay Climate Control Commercial Unitary Rooftop CUR 075-150 Vintage F Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationRP6.52Y (ERRATA 1) (202) 2 of 12
530.18-RP6.52Y (ERRATA 1) (202) 2 of 12 ELECTRICAL (Cont.) FIG ITEM UNIT D4CG150N16525 D4CG150N16546 D4CG150N16558 DESCRIPTION STYLE 5-BURNER 5-BURNER 5-BURNER * 18 CONNECTOR, CAP (6-CIRCUIT) 025-20963-000
More informationCOMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A
COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A CATALOG NO. 9300.90 Effective: 12-13-13 Replaces: NEW RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 1005A, 1505A & 2005A MODEL TYPES: MODULATING VERTICAL BOILER
More informationCOS-8G & COS-8GDS COMBI OVENS BCS-G STEAMER CNV-8G CONVECTION OVEN REPLACEMENT PARTS LIST
COS-G & COS-GDS COMBI OVENS BCS-G STEAMER CNV-G CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 0, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in
More informationThis parts list is current as of the above revision date. See for the current revision.
Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Package Gas-Electric - Commercial Table of Contents Model
More informationMcQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996
Replacement Parts List No. 779200300 Revision C 04/2011 McQuay Climate Control Singer Rooftop Unit ER, R 080 Vintage A, B, C, D Last Manufactured: 1996 To find your Daikin Applied parts distributor, call
More informationCGa - Series 1 & 2 Section Assembly Parts
CGa - Series & Section Assembly Parts 0 Part Description Mfr. Mfr. s Part Boiler -0-0 End Section, Left Hand, Cast # -0- End Section, Right Hand, Cast # -0- Intermediate Section, Cast #, -- -- Replacement
More information15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS
Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.
More informationRAYPAK ILLUSTRATED PARTS LIST
RAYPAK ILLUSTRATED PARTS LIST The parts listed are for standard equipment for this model type. Raypak reserves the right to substitute, delete or change any part without notification. The addition of options
More informationPARTS MANUAL. American Dish Service MODELS: ADC-44 L-R/R-L ADS CONVEYOR DISHWASHER EFFECTIVE: MAY, 2008
EFFECTIVE: MAY, 2008 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2 211-0044L-R
More informationParts List Charging Charts & Wiring Diagrams
Parts List Charging Charts & Wiring Diagrams Models PGE300H275A PGE300L275A PGE300H360A PGE300L360A PGE300S360A Table of Contents Page Parts Drawings 2 to 7 Parts list 8 to 13 Charging data 14 & 15 Wiring
More informationWarm. SDFI Direct Fired Gas Heating System. Sterling. Keeps You. Technical Guide for: Indoor Mounted Units To 64,000 CFM And 9M BTUH
TGSDFI- SDFI Direct Fired Gas Heating System Technical Guide for: Indoor Mounted Units To 64,000 CFM And 9M BTUH Sterling Keeps You Warm Featuring the Patented AirTrak controlled Air Circulation System
More informationCrest Heating Boilers FBN(L)
Replacement Parts List S & SERVICE DEMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 2500-6000 69 67 59 62 79 18 26 66 76
More informationHE, HEII and VHE Section and Base Assembly
HE, HEII and Section and Base Assembly 68 Discontinued Service s HE, HEII and Section and Base Assembly GAS s not listed below are obsolete and no longer available. s listed below may become obsolete.
More informationComfort Pack Archived Part Lists PARTS LISTS
Comfort Pack Archived Part Lists PARTS LISTS CPGXX38-X Description 14208336 Natural Gas Orifice - 38 14208343 LP Gas Conversion Kit - 38 14208329 Heat Exchanger Assembly - 38 14208332 Full Burner Body
More informationIMPORTANT: When ordering parts, please provide the model, gas type and serial number of the oven The identification plate is located on the back of th
MG3270 & MG-32 CONVEYOR OVEN REPLACEMENT PARTS LIST EFFECTIVE SEPTEMBER 13, 2001 BLODGETT OVEN COMPANY, 50 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 860-3700 (800) 331-5842 Fax: (802)
More informationHeater Parts. LXi Low NOx. See Detail on next page Zodiac Pool Systems, Inc. Product Catalog. Heater Parts. After. July Before.
LXi Low NOx 47 23 After July 2009 23 65 48 33 28 65 50 49 Before July 2009 22 26 Detail 22 63 64 25 67 25 9 62 33 27 6 34 35 62 4 36 2 32 20 57 60 8 72 58 59 7 52 56 4 54 53 7 68 70 69 90 55 6 See Detail
More informationFigure 1-1(d) Tft Installation Kit
TRINITY TFT60-399 PARTS LIST For a list of parts that corresponds to the item numbers in the callouts, refer to Table 1-1. Note that some item numbers may appear more than once in the parts list depending
More informationENGINEERED PRODUCTS. Project: Unit Tag: MS-80-D-3 Page 1 of 5
ENGINEERED PRODUCTS Model - Unit Type (UT) - MS, Separated Combustion Indoor Unit Capacity (CA) - (50-80) (500-800 mbtu) Furnace Type (FT) - A, B Standard Temperature Rise (30-80)F Indoor Arrangement (IA)
More informationCGi Series 2 Section Assembly
CGi Series 2 Section Assembly 8 0 2 9 9 Current Service Parts CGi Series 2 Section Assembly Part Description Mfr. Mfr. s Part -0-80 End section, left hand, cast #2 Weil-McLain 2-0-82 End section, right
More informationWestinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975
Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS OV310G MINI RACK OVEN ML-132515 OV310G A product of BAXTER MFG. CO., INC. 19220 STATE ROUTE 162 EAST, ORTING, WA 98360 FORM 43242 Rev. D (January 2018) F-43242 Rev. D (January
More informationInterior Tankless Models
GAS REPLACEMENT PARTS LIST Interior Tankless Models TG-15OI-(N,X) TG-180I-(N,X) TG199I-(N,X) TG-237I-(N,X)(A) Effective: May, 2013 ECO 7853 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING
More informationRAYPAK ILLUSTRATED PARTS LIST
COMMERCIAL and POOL MODELS: 992B THRU 2342B CATALOG NO. 9300.762 Effective: 11-30-12 Replaces: 05-13-11 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 992B, 1262B, 1532B, 1802B, 2002B, 2072B & 2342B MODEL
More informationDrying Tumblers 120 Pound Capacity Refer to Page 3 for Model Numbers Cover
HIGH LOAD READY MEDIUM TEMPERATURE LOW LOW AIR FLOW NON REV REV PUSH TO START 0 5 5 0 50 40 60 0 30 0 0 Drying Tumblers 0 Pound Capacity Refer to Page 3 for Model Numbers Cover Parts COOLING DRYING T0C
More informationIntroduction. System Components
The Selectra SERIES 94 is for use with either direct or indirect gas fired units (furnaces, ovens, etc.). The system may be field installed on existing equipment or specified for new equipment installation.
More informationModels. Save This Manual For Future Reference. International Comfort Products Corporation (USA) Lewisburg, TN USA LP1 5/16/
Models NTC7050BFG / GNL050NG NTC7075BFG / GNL075NG NTC700BHG / GNL00N6G NTC75BKG / GNL5N0G NDC7050BFG / GDL050NG NDC7075BFG / GDL075NG NDC700BHG / GDL00N6G NDC75BKG / GDL5N0G Manufactured by: International
More informationParts Manual. with Wiring Diagrams for domestic ovens PS870 WOW SERIES GAS FIRED: Table of Contents: Page 2.
A MIDDLEBY COMPANY PS870 WOW SERIES GAS FIRED: SPL062506-PF-BD June 25, 2006 Parts Manual with Wiring Diagrams for domestic ovens Serial # Code First 4 digits - order of production Fifth digit - model
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS HBA SERIES GAS RACK OVEN HBA1G HBA2G ML-132358 ML-132280 A product of HOBART 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43070 Rev. C (June 2008) - 2 - HOBART Table of Contents
More information15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE
Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.
More information60Hz UP6 15, UP6 20, UP6 25, UP6 30
60Hz UP6 15, UP6 20, UP6 25, UP6 30 en fr pt es PARTS CATALOGUE CATALOGUE DE PIÈCES DÉTACHÉES LISTA DE PEÇAS LISTA DE REPUESTOS zh C.C.N : 80445166 REV. : A DATE : OCTOBER 2008 CONTENTS Page T N o Page
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE
COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct
More informationLIST PRICES WAC AIR CURTAINS
PRICE SHEET PSWAC-2 EFFECTIVE: March 1, 2011 SUPERSEDES: PSWAC-1 LIST PRICES WAC AIR CURTAINS 4830 TRANSPORT DRIVE, DALLAS, TX 75247 PHONE: 214-638-6010 FAX: 214-905-0806 WAC AIR CURTAINS Basic Unit ITEM
More informationLow BTU Copper Brute TM II Series Models: BWCV0200 BWCV0300 BWCV0400
COMMERCIAL GAS REPLACEMENT PARTS LIST Low BTU Copper Brute TM II Series Models: BWCV0200 BWCV0300 BWCV0400 Effective: March, 2007 ECO 7206 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING
More informationClimas y Proyectos Leyco, S.A. de C.V.
GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS COMBI GAS OVENS MODELS ML-126836 ML-126837 ML-126838 VCG10H VCG10F VCG20H For additional information on Vulcan-Hart Company or to locate an authorized parts and service provider
More informationDaikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)
Replacement Parts List No. 700018700 Revision E 04/2015 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design C (3) To find your Daikin Applied parts distributor,
More informationRAYPAK ILLUSTRATED PARTS LIST
COMMERCIAL/POOL MODELS: MVB 504A THRU 2004A CATALOG NO. 9300.745 Effective: 11-01-18 Replaces: 12-01-17 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 504A, 754A, 1104A, 1504A & 2004A MODEL TYPES: MODULATING
More informationBG2136 CONVEYOR OVEN REPLACEMENT PARTS MANUAL (with WIRING DIAGRAMS)
SPL102505-PF-BD October 25, 2005 BG2136 CONVEYOR OVEN REPLACEMENT PARTS MANUAL (with WIRING DIAGRAMS) Serial Tag Location EFFECTIVE with SERIAL #401811005 and AFTER Serial # Code First 4 digits - order
More informationDaikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018
Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationICEMINI & Vertical MTI Units
ICEMINI & Vertical MTI Units ICEMINI Units......K-1 ICEMINI-8MPN (Dimension Information)....... K-2 ICEMINI-8MPN (Horizontal Small)....... K-3 ICEMINI-8MPN (Vertical Small)........ K-4 ICEMINI-8MPN (Vertical
More informationPart List: Jandy LXI Series Heaters
Part List: Jandy LXI Series Heaters Models LXI250, LXI400 For pool heater parts, equipment and any pool accessories, visit www.torontopoolsupplies.ca 1-844-416-7665 416-623-9334 info@torontopoolsupplies.ca
More informationREPAIR PARTS. DCG 12.5 Ton Package Gas Unit. This manual is to be used by qualified technicians only. This manual replaces RP-D1011E.
REPAIR PARTS DCG 12.5 Ton Package Gas Unit DCG1502103BAXGAA DCG1502103BAXXAA DCG1502103BAXYAA DCG1502103BHXAAA DCG1502103BHXXAA DCG1502103BJXAAA DCG1502103BXSXAA DCG1502103BXXCAA DCG1502103BXXNAA DCG1502103BXXXAA
More informationWestinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975
Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call
More informationAir Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011)
Air Handlers ACBX32CM 3 Phase Multi-Position ACBX32CM-100 (07/2011) FEATURES AND BENEFITS Application Environmentally friendly R410A refrigerant 3, 4, and 5 ton nominal capacities Multi-position applications
More informationMcQuay Package System MPS062E, MPS070E, MPS075E PL
McQuay Package System 062E, 070E, 075E PL-1003-8 062E / 070E / 075E 1 062E / 070E / 075E 2 062E / 070E / 075E 3 062E / 070E / 075E 4 062E / 070E / 075E 5 062E / 070E / 075E 6 062E / 070E / 075E 7 8 Section
More informationReplacement Parts List
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Copper-Fin II Boilers Water Heaters CH CF 992-2072 50 17
More informationSUBMITTAL COVER SHEET
SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg.
More informationDrying Tumblers 110 Pound Capacity Refer to Page 3 for Model Numbers. Parts
Drying Tumblers 0 Pound Capacity Refer to Page 3 for Model Numbers Parts Part No. M444R April 000 Table of Contents Title Page Parts Ordering Information... Nameplate Location... Model Identification...
More informationnufacturing Company, L.P San Felipe, Suite 500
Commercial 20 Ton Package Gas Units DCG2404003BAXAAA DCG2404003BXXXAA DCG2404004BXXXAA DCG2404004BXXXAB DCG2404007BXXXAA REPAIR PARTS nufacturing Company, L.P. 5151 San Felipe, Suite 500 www.amana-hac.com
More informationX4 Installation and Operation Manual - POWER FLAME INCORPORATED
7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice
More informationSECTION 8. PARTS INFORMATION
SECTION 8. PARTS INFORMATION 8-1. INTRODUCTION This section lists the replaceable parts of the Henny Penny Model LVG fryer. 8-2. GENUINE PARTS Use only genuine Henny Penny parts in your fryer. Using a
More informationSubmittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]
BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing
More informationac-500 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven
ac-00 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven REPLACEMENT PARTS LIST Effective june, 0 Superseding All Previous Parts Lists. The Company reserves the right to make
More informationSeries 20 Installation Instructions
Series 20 Installation Instructions Installation Instructions and field service checklist Read these instructions carefully. Failure to follow them could result in a fire or explosion causing property
More informationParts Manual. with Wiring Diagrams for domestic and standard export ovens PS536GS SERIES GAS FIRED: Table of Contents: Page 2.
A MIDDLEBY COMPANY PS536GS SERIES GAS FIRED: SPL090205-PF-BD September 9, 2005 Replaces PMD-15-006 Rev. B V1 2/03 Parts Manual with Wiring Diagrams for domestic and standard export ovens Serial # Code
More informationReplacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev V
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 615-889-8900 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Armor Condensing Water Heater AW 151 thru 801 41 4 10 38
More informationRAYPAK ILLUSTRATED PARTS LIST
COMMERCIAL MODELS: MVB 503A THRU 2003A CATALOG NO. 9300.744 Effective: 12-01-17 Replaces: 03-01-17 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 503A, 753A, 1003A, 1253A, 1503A, 1753A & 2003A MODEL TYPES:
More informationUB Series 2 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER. Models UB90-50 UB90-75 UB90-100
UB90-100 Series 2 Models UB90-50 UB90-75 UB90-100 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model
More informationMDG78 Complete Dryer Assembly Piece Back Guard Assembly (gas and electric) Top Back Guard (gas and electric) Bottom Bac
Complete Dryer Assembly MDG78 4 Maytag 450662-1 MDG78 Complete Dryer Assembly 1 822363 1 2-Piece Back Guard Assembly (gas and electric) 320674 1 Top Back Guard (gas and electric) 323372 1 Bottom Back Guard
More informationAC-500 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST
AC-00 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 9, 0 Superseding All Previous Parts Lists. The Company reserves the right to
More informationWarm. SDR Direct Fired Gas Heating System. Sterling. Keeps You. Technical Guide for: Outdoor or Indoor Mounted Units To 16,000 CFM And 1.
TGSDR- SDR Direct Fired Gas Heating System Technical Guide for: Outdoor or Indoor Mounted Units To 16,000 CFM And 1.97M BTUH Sterling Keeps You Warm Featuring the Patented AirTrak controlled Circulation
More informationA.O. SMITH WATER PRODUCTS CO., INC W. 115TH STREET ALSIP, ILLINOIS Phone: Fax: Website:
PSD-3-152/a WIRING/HARNESS & PROBES See page 8 PROPANE GAS TRAIN ASSEMBLY See page 6 COMMERCIAL POWER BURNER BOILER REPLACEMENT PARTS LIST COPPER BOILERS FOR HYDRONIC HEATING & HOT WATER SUPPLY LEGEND
More informationMT3270 & MT3255 SERIES CONVEYOR OVEN REPLACEMENT PARTS LIST
APRIL 1999 MT3270 & MT3255 SERIES CONVEYOR OVEN REPLACEMENT PARTS LIST MT3255 A Division of G.S. Blodgett Corporation Superseding All Previous s Lists. The Company reserves the right to make substitution
More informationProduct Data. that this product meets the S 95% AFUE S Two -stage operation
DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling
More informationQ90-50/75/100 Series 4
Q90-50/75/100 Series 4 Models Q90-50 Q90-75 Q90-100 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS AND OPTIONAL ACCESSORIES Ordering Instructions Order Parts through your nearest supplier.
More informationPGC COMMERCIAL PACKAGED GAS/ELECTRIC
PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationUB90-50/75/100 Series 4
Models UB90-50 UB90-75 UB90-100 UB90-50/75/100 Series 4 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS AND OPTIONAL ACCESSORIES Ordering Instructions Order Parts through your nearest
More informationULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION
RESIDENTIAL AND COMMERCIAL GAS REPLACEMENT PARTS LIST ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION EFR160T120*(EN,SX) EF(60,100)T(125-300)(E*N)(*X)(A)2 (Serial Number GB13006174 and AFTER) Includes
More informationAF90. AF90 Gas Furnace High Efficiency. Features
AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948
More informationQ90-50/75/100 Series 2 Q Series 3
Models Q90-50 Q90-75 Q90-100 Q90-50/75/100 Series 2 Q90-100 Series GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS AND OPTIONAL ACCESSORIES Ordering Instructions Order Parts through your
More informationReplacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Armor Condensing Water Heater AW 151 thru 801 41 4 10 38
More informationXC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace
TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VA, TDHMB060BCV3VA TUHMB080ACV3VA, TDHMB080ACV3VA
More informationKalahari & GlowPlus. Kalahari and GlowPlus Heaters Issue 1. Nov 09
Kalahari & GlowPlus Kalahari Room Heater Natural Gas Models: Kalahari-18-NG and Kalahari-25-NG Kalahari Room Heater Natural Gas Item Description Part No. 1 Front Cover Assembly 05-27715- 2 Filter Assembly
More informationnufacturing Company, L.P San Felipe, Suite 500
Commercial 10 Ton Package Gas Unit DCG1202103BHXBAA DCG1202103BHXXAA DCG1202103BJXVAA DCG1202103BXXHAA DCG1202103BXXXAA DCG1202104BXXXAA DCG1202104BXXXAB DCG1202107BXXXAA REPAIR PARTS nufacturing Company,
More informationG21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993
ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE GAS FURNACES SYSTEMS 50hz G21Q PULSE21 SERIES UP-FLO GAS FURNACES 11.4 to 27.8 kw (39 000 to 95 000 Btuh) Output Add-On Cooling 5.3 thru 17.6 kw (1-1/2
More information