Product Data 58GFA. Induced-Combustion Upflow Furnace Heating Inputs: 65,000 thru 150,000 Btuh. 78% AFUE With Continuous- Pilot Ignition

Size: px
Start display at page:

Download "Product Data 58GFA. Induced-Combustion Upflow Furnace Heating Inputs: 65,000 thru 150,000 Btuh. 78% AFUE With Continuous- Pilot Ignition"

Transcription

1 Product Data 58GF Induced-ombustion Upflow Furnace Heating Inputs: 65,000 thru 150,000 Btuh 78% FUE With ontinuous- Pilot Ignition arrier is the first manufacturer to provide a 78% nnnual Fuel Utilization Efficiency (FUE) gas furnace for the budget conscious consumer and builder. The 58GF offers the same high quality you demand from arrier. The superior attention to cabinet detail is obvious. The arrier 58GF features 1-piece, seamless, wrap-around construction. There are no spot welds on the exterior surfaces of the furnace. There is also double protection for the cabinet. First, a galvanized steel substrate provides resistance to rusting; then the cabinet is constructed of prepainted steel the same highquality finish found on refrigerators and dishwashers. The 58GF offers a proven continuous-pilot ignition system which provides superior reliability. arrier s patented Super-S heat exchanger improves heat transfer and enables downsizing of this furnace to only 40-in. tall. It is covered by a 10-year heat exchanger Limited Warranty. The solid-state control board is the brain of this induced-combustion gas furnace. The control board features a -amp fuse which protects the 24-v control transformer. opyright 1996 arrier orporation Form 58GF-PD

2 1 OM PR-2 L2 E-2 FR LO HI E-1 HFR L1 PR PL SPRE-1 IDR SPRE-2 SE-2 SE-1 W Y1 R G FU -MP FUSE GROUND SREW ES V OMMON BLOWER OFF-DELY REQUIRED HET EXHNGER PRINTED-IRUIT BORD INDUER BLOWER ama NDIN GS SSOITION R PPROVED MEETS DOE RESIDENTIL ONSERVTION SERVIES PROGRM STNDRDS. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Model number nomenclature Induced-ombustion Upflow Furnace Input apacity 065 6,000 Btuh ,000 Btuh ,000 Btuh ,000 Btuh ,000 Btuh 58GF Series Number ooling Size (irflow) (400 FM per 12,000 Btuh) FM FM FM FM FM FM 2

3 NOTES: 1. The 58GF Furnaces are for use with natural gas. These furnaces can be field converted for propane gas with a factory-authorized and listed accessory conversion kit. 2. ontrol location and actual control may be different than shown above. 1 Relief Box 7 Blower and Blower Motor 2 Gas Valve ontrol Knob (On, Pilot, Off) 8 Draft Safeguard Tube and Switch Gas Valve 9 Rating Plate (Behind Junction Box) 4 Gas Burner 10 Gas Manifold 5 Pilot Burner and Thermocouple 11 Filter Retainer 6 Blower Door Safety Switch 12 ir Filter

4 arrier accessories* 5 8 FILTER FRME FILTER B FILTER FILTER B FURNE 9067 RETURN-IR PLENUM ustom-made return-air plenum can be mounted on either side of the furnace. Includes washable filters. B 25 in. 16 in. 9-7/8 in. FURNE DOOR 9068 SIDE FILTER RK ustom made filter rack for easy connection when a return plenum already exists. Provides easy access for cleaning filter. B 2-1/8 in. 2-/8 in. 14-1/2 in MEHNIL OR ELETRONI IR LENER leans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Mechanical air cleaner is shown MODEL 49FH HUMIDIFIER By adding moisture to winter-dry air, a arrier humidifier can often improve the comfort and keep furniture, rugs, and draperies in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures. UNIT SIZE & & , 16, & & IR LENER Model IR, KE, 1MF, or MEH HUMIDIFIER Model 49BF, 49BG, 49FH, 49FP, or 49WS VENTILTOR Model VB, VB5B, V5B, or VL THERMOSTT NON-PROGRMMBLE For Use with ir onditioner TSTTN01- For Use with Heat Pump TSTTNHP01- THERMOSTT PROGRMMBLE For Use with ir onditioner TSTTP01- For Use with Heat Pump TSTTPHP01- RETURN-IR PLENUM (With Washable Filters) KGRP0201LL SIDE FILTER RK (ccepts Filter) KGFR0206LL TWINNING KIT KGTW0501STP GS ONVERSION KIT Natural-To-Propane KGNP2001LL Propane-To-Natural KGPN1601LL *Factory-authorized and field installed. Gas conversion kits are.g.. recognized. Physical data UNIT SIZE OUTPUT PITY BTUH Nonweatherized IS** 51,000 51,000 67,000 68,000 85,000 85,000 84, , , ,000 INPUT BTUH* 6,000 6,000 84,000 84, , , , , , ,000 SHIPPING WEIGHT (Lb) ERTIFIED TEMP RISE RNGE ( F) ERTIFIED EXT STTI PRESSURE (In. wc) Heating ooling IRFLOW FM Heating LIMIT ONTROL HETING BLOWER ONTROL ooling * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4% for each 1000 ft above sea level. apacity and FUE in accordance with U.S. Government DOE test procedures. ir delivery above 1800 FM requires that both sides, or a combination of 1 side and bottom, or bottom only of the furnace be used for return air. filter is required for each return-air supply. ** Isolated ombustion System SPST Solid-State Time Operation BURNERS (Monoport) GS ONNETION SIZE GS VLVE (Redundant) Manufacturer Minimum Inlet Pressure (In. wc) Maximum Inlet Pressure (In. wc) IGNITION DEVIE 1/2-in. NPT Honeywell 4.5 (Natural Gas) 1.6 (Natural Gas) Thermocouple-Type ontinuous Pilot 4

5 Dimensions LERNES (In.) UNIT SIZE Sides Single-Wall Vent 1 0 Type B-1 Double-Wall Vent 0 0 Back 0 0 Top of Plenum 1 1 Vent onnector Single-Wall Vent 6 6 Type B-1 Double- Wall Vent 1 1 Front* Single-Wall Vent 6 6 Type B-1 Double-Wall Vent Service 0 0 * The -in. front clearance is needed for combustion-air and ventilationair entry. DIMENSIONS (In.) UNIT SIZE D E VENT ONN* / / / / / / /2 15-7/ /8 18-1/ /2 15-7/ /8 18-1/ /2 22-7/ /8 18-/ /2 22-7/ /2 22-7/ * Refer to the furnace Installation Instructions for proper venting procedures. IRFLOW FLUE OLLR D OUTLET IN. DI HOLE POWER ENTRY 7 8-IN. DI ESSORY IN. DI POWER ENTRY IN. DI R.H. GS ENTRY IN. DI HOLE GS ENTRY 1 2-IN. DI HOLE THERMOSTT WIRE ENTRY IN. DI ESSORY 1 2-IN. DI THERMOSTT WIRE ENTRY SIDE INLET SIDE INLET TYP IR INLET E TYP SIDE RETURN DUT LOTION NOTES: 1. Two additional 7 8-in. dia holes are located in the top plate. 2. Minimum return-air opening at furnace: a. For 800 FM 16-in. round or x 12-in. rectangle. b. For 1200 FM 20-in. round or x in. rectangle. c. For 1600 FM 22-in. round or x in. rectangle. d. For airflow requirements above 1800 FM, use both side inlets, a combination of 1 side inlet and the bottom, or the bottom only Performance data UNIT SIZE DIRET-DRIVE MOTOR Hp (PS) 1/5 1/ 1/ 1/2 1/ 1/2 /4 1/2 /4 /4 MOTOR FULL LOD MPS RPM (Nominal) SPEEDS BLOWER WHEEL DIMETER x WIDTH (In.) 10 x 6 10 x 6 10 x 7 10 x 8 10 x 7 10 x 8 11 x x 8 11 x x 10 WSHBLE 16 x 25 x 1-In. FILTER No WSHBLE 20 x 25 x 1-In. FILTER No WSHBLE 24 x 25 x 1-In. FILTER No PS Permanent Split apacitor 5

6 ENERGY EFFIIENY UNIT SIZE PITY* Nonweatherized IS 51,000 51,000 67,000 68,000 85,000 85,000 84, , , ,000 FUE %* Nonweatherized IS * apacity and FUE in accordance with U.S. Government DOE test procedures. Isolated ombustion System IR DELIVERY FM (WITH FILTER)* UNIT SIZE EXTERNL STTI PRESSURE (IN. W) SPEED High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low High Med-High Med-Low Low * ir delivery above 1800 FM requires that both sides, or a combination of 1 side and bottom, or bottom only of the furnace be used for return air. filter is required for each return-air supply. Indicates unstable operating conditions. 6

7 Typical wiring schematic FIELD 24-VOLT WIRING FIELD 115-, 208/20-, 460-VOLT WIRING FTORY 24-VOLT WIRING FTORY 115-VOLT WIRING FIVE WIRE NOTE 2 W R G Y THERMOSTT TERMINLS FIELD-SUPPLIED FUSED DISONNET BLK BLK THREE-WIRE HETING- ONLY W 208/20- OR 460-VOLT THREE PHSE WHT GND WHT 115-VOLT FIELD- SUPPLIED FUSED DISONNET GND UXILIRY J-BOX ONTROL BOX R G Y 24-VOLT TERMINL BLOK FURNE NOTE 1 NOTES: ONDENSING UNIT TWO WIRE GND 208/20- VOLT SINGLE PHSE 1. onnect Y-terminal as shown for proper operation. 2. Some thermostats require a "" terminal connection as shown.. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire Electrical data UNIT SIZE UNIT VOLTS HERTZ PHSE MINIMUM WIRE SIZE MXIMUM WIRE LENGTH* (Ft) MXIMUM UNIT MPS OPERTING VOLTGE RNGE (Min Max) MXIMUM FUSE SIZE OR HR-TYPE KT BKR (mps) TRNSFORMER (24v) 40va EXTERNL ONTROL POWER VILBLE Heating 21va ooling 2va IR ONDITIONING BLOWER RELY Standard * Length shown is as measured 1 way along wire path between unit and service panel for maximum 2% voltage drop. Permissible limits of the voltage range at which the unit will operate satisfactorily. Time-delay fuse is recommended. 7

8 Typical installations ONDENSING UNIT HUMIDIFIER ELETRONI IR LENER GS-FIRED WTER HETER IRFLOW SERVIE TRINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence large selection of product, theory, and skills programs is available, using popular video-based formats and materials. ll include video and/or slides, plus companion book. lassroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. ourse descriptions and schedules are in our catalog. LL FOR FREE TLOG [ ] Packaged Service Training [ ] lassroom Service Training 9428 opyright 1996 arrier orporation Syracuse, New York Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Page 8 atalog No Printed in U.S.. P 101 Form 58GF-PD Tab 6a 8a Replaces: 58GF-2PD

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

TECHNICAL GUIDE MODELS: MA MODULAR AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MA MODULAR AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TEHNIL GUIDE MODELS: MODULR IR HNDLERS FOR USE WITH SPLIT SYSTEM OOLING & HET PUMP 600-2000 FM BLOWERS 2-5 TON OILS OPTIONL 1 & 3φ ELETRI HETERS ISO 9001 ertified Quality Management System Due to continuous

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

G8MVL. Product Specifications

G8MVL. Product Specifications 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

F8MTL. Product Specifications

F8MTL. Product Specifications 80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115

More information

U L OIL-FIRED FURNACES. Stellar MBH OUTPUT 80 AFUE DESCRIPTION FEATURES MULTI-POSITION MODELS - P1FM DOWNFLOW/HORIZONTAL MODELS - P1FH

U L OIL-FIRED FURNACES. Stellar MBH OUTPUT 80 AFUE DESCRIPTION FEATURES MULTI-POSITION MODELS - P1FM DOWNFLOW/HORIZONTAL MODELS - P1FH 660.06-TGY (795) MULTI-POSITION S - PFM Stellar 2000 OIL-FIRED FURNES 55-200 MH OUTPUT 80 FUE U L DOWN/HORIZONTL S - PFH DESRIPTION These oil-fired furnaces are compact, decorator-styled warm air heating

More information

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TEHNIL GUIDE MODELS: MV MODULR VRIBLE SPEED IR HNDLERS FOR USE WITH SPLIT SYSTEM OOLING & HET PUMP 1200-2000 FM BLOWERS 3-5 TON OILS OPTIONL 1 & 3 ELETRI HETERS Due to continuous product improvement, specifications

More information

WFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. F verification of certification f individual products, go to www.ahridirecty.g.

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Product Data. Residential Zone Dampers FEATURES/BENEFITS

Product Data. Residential Zone Dampers FEATURES/BENEFITS Product Data Residential Zone Dampers FETURES/ENEFITS IRFLOW CLS COM OPN IRFLOW 90 0 45 ROUND DMPER CLS COM OPN 90 0 45 RECTNGULR DMPER Carrier residential zone dampers are the latest in design and were

More information

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved

More information

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a

More information

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Product Data. that this product meets the S 95% AFUE S Two -stage operation DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling

More information

Upflow, Upflow / Horizontal, Counterflow / Horizontal

Upflow, Upflow / Horizontal, Counterflow / Horizontal Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long

More information

AF90. AF90 Gas Furnace High Efficiency. Features

AF90.   AF90 Gas Furnace High Efficiency. Features AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty

More information

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

Installation Instructions

Installation Instructions Motor Master ontrol Kit ancels: IIK 561A-18-1 IIK 561-18-1 11-95 Installation Instructions Part No. 32LT660004 and 005 This symbol indicates a change since last issue. INTRODUTION These instructions cover

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES TEHNIAL GUIDE SINGLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLING & HEAT PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 DESRIPTION This fan coil line offers the ultimate in application flexibility.

More information

TSTAT0101SC Recommended (sold separately)

TSTAT0101SC Recommended (sold separately) Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor 80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor A80-1E Form No. A80-1E-100 (10/2011) Features and Benefits CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped

More information

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS 80% Gas Furnace Single Stage - High Efficiency (Constant Torque) Motor 80G1-E Features and Benefits Form No. R80G1-E-100 (11/2011) CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped

More information

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal

More information

TECHNICAL GUIDE 80 AFUE MULTI-POSITION GAS FURNACES MODELS: G8C SERIES 4-POSITION MBH INPUT 3-POSITION 150 MBH INPUT DESCRIPTION WARRANTY

TECHNICAL GUIDE 80 AFUE MULTI-POSITION GAS FURNACES MODELS: G8C SERIES 4-POSITION MBH INPUT 3-POSITION 150 MBH INPUT DESCRIPTION WARRANTY TEHNIAL GUIE 80 AFUE MULTI-POSITION GAS FURNAES MOELS: G8 SERIES 4-POSITION 50-125 MH INPUT 3-POSITION 150 MH INPUT EFFIIENY RATING ERTIFIE ISO 9001 ertified Quality Management System ESRIPTION These compact

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

Upflow, Upflow / Horizontal, Counterflow

Upflow, Upflow / Horizontal, Counterflow , / Horizontal, 90/92 Gas Furnace CG90/92 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long life AL29-4C Stainless

More information

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING 92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h / Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing

More information

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized

More information

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FGT (A and K Series) Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The high efficiency

More information

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140 PERFORMANCE 80 TWO --- STAGE 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140 Product Data A10249 THE PERFORMANCE 80 GAS FURNACE The Two-Stage,

More information

93% Gas Furnaces Single Stage

93% Gas Furnaces Single Stage Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 93% Gas Furnaces Single Stage Form No. AA931A-100 (05/2012) HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped

More information

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev. TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose

More information

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace RGPT- Series 80% A.F.U.E. Input Rates 50-125 kbtu ENER UIDE Annual Fuel Utilization Efficiency

More information

Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig. 3 - Slip -In Damper. Fig. 1 - Round Damper

Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig. 3 - Slip -In Damper. Fig. 1 - Round Damper CLS COM OPN CLS COM OPN ZONE ERS Product Data IRFLOW IRFLOW Fig. 3 - Slip -In Damper 05253 Fig. 1 - Round Damper 05251 FETURES/ENEFITS CLS COM OPN Carrier zone dampers are the latest in design and were

More information

Rheem Value Series Upflow/Horizontal Gas Furnace

Rheem Value Series Upflow/Horizontal Gas Furnace THIS MODEL Gas Furnaces Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE 80.0% MID HIGH 78% 82% 88%

More information

Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig.3 Slip-InDamper. Fig.1 RoundDamper

Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig.3 Slip-InDamper. Fig.1 RoundDamper CLS COM OPN CLS COM OPN CLS COM OPN ZONE ERS Product Data IRFLOW IRFLOW 05253 Fig.3 Slip-InDamper Fig.1 RoundDamper 05251 FETURES/ENEFITS Carrier zone dampers are the latest in design and were developed

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-485 REV. 4 Supersedes Form No. G22-485 Rev. 3 GAS FURNACES UGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 1 Supersedes Form No. G66-478 Rev. 0 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing line of upflow/horizontal gas furnaces are designed for utility rooms, closets,

More information

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

FG7S (C and L Series)

FG7S (C and L Series) TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE / SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel

More information

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE FORM NO. G22-448 REV. 10 Supersedes Form No. G22-448 Rev. 9 GAS FURNACES UGPH- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

DM96HS / DC96HS. Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DM96HS / DC96HS. Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 10,000 BTU/h Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... 3 Dimensions... 5 Airflow Specifications... 7 Wiring Diagram...

More information

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h // Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units

More information

Cabinet Features. upflow, horizontal left or right matically adjusts to high or low stage

Cabinet Features. upflow, horizontal left or right matically adjusts to high or low stage Two-Stage, onvertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 140,000 BTU/h ontents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8

More information

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN A951E PRODUCT SPECIFICATIONS SINGLE STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A951E-100 (10/2018) CONTROLS Single stage gas valve Durable silicon nitride ignitor Self diagnostics saves

More information

AMVC8/ADVC8. Heating Input: 60, ,000 BTU/h

AMVC8/ADVC8. Heating Input: 60, ,000 BTU/h MV8/DV8 Heating Input: 60,000 00,000 TU/h Two-Stage Variable Speed Gas Furnace 80% FUE Standard Features Two-stage gas valve operates on twostage or single-stage thermostats omfortnet ommunications System

More information

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-486 REV. 3 Supersedes Form No. G11-486 Rev. 2 GAS FURNACES RGPP- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303) TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION DESCRIPTION These high efficiency, dedicated downflow compact units employ induced

More information

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces THIS MODEL 78% 82% 88% 92.0% 97% Air Gas Furnaces Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces RGPQ- Series 80% A.F.U.E. Models with Input Rates from 45-105 kbtu (U.S. & Canadian Models)

More information

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest Product Data FA4A FB4A Direct Expansion Fan Coil Sizes 08 thru 070 Air Handling Technology At Its Finest Carrier s FA4A, FB4A, and direct expansion multipoise fan coils are designed to cover a wide range

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS

A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE FORM NO. A97MV-100 (06/2014) CONTROLS Communicating control enabled Modulating gas valve Thermostat flexibility: works with the Comfort

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G66-496 REV. 5 Supersedes Form No. G66-496 Rev. 4 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 96G1E-100 (04/2018) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS

93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS 93% Single Stage Gas Furnace Form No. JA931A-100 (08/2010) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped no

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FG7T (A and K Series), Smartlite Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The

More information

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11

More information

Product Data PG9UAA DEDICATED UPFLOW VARIABLE-SPEED 95% AFUE CONDENSING GAS FURNACE FEATURES

Product Data PG9UAA DEDICATED UPFLOW VARIABLE-SPEED 95% AFUE CONDENSING GAS FURNACE FEATURES DEDICATED UPFLOW VARIABLE-SPEED 95% AFUE CONDENSING GAS FURNACE Product Data FEATURES This intelligent heating control constantly monitors operating conditions to adjust for greater efficiency and comfort.

More information

FG7T (E and N Series)

FG7T (E and N Series) TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICL GUIDE SPLIT-SYSTEM EVPORTOR LOWERS K*ES120 10 NOMINL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling coil

More information

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) C9MVX SoftSound VS90 Product Specifications 95% Variable Speed Two Stage Heating Furnace FLEXIBILITY Supports two stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40in (1016mm)

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG) MODEL NO. THV1C072A948SA (BECKETT AFG) THV1C072A9V4SA (BECKETT AFG) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000

More information

KG7S (A and K Series)

KG7S (A and K Series) TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed

More information

L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE VENTING WARRANTY GENISYS ADVANCED BURNER CONTROL CONFIGURATIONS HEAT EXCHANGER CABINET BLOWER BURNER

L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE VENTING WARRANTY GENISYS ADVANCED BURNER CONTROL CONFIGURATIONS HEAT EXCHANGER CABINET BLOWER BURNER L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE FORM NO. L83-100 (07/2014) VENTING Includes field installed barometric damper Optional sidewall vent kit available WARRANTY 10 year limited parts warranty / lifetime

More information

Rheem Value Series Downflow Gas Furnace

Rheem Value Series Downflow Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Value Series Downflow Gas Furnace RGLS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID A.F.U.E.

More information