Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

Size: px
Start display at page:

Download "Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest"

Transcription

1 Product Data FA4A FB4A Direct Expansion Fan Coil Sizes 08 thru 070 Air Handling Technology At Its Finest Carrier s FA4A, FB4A, and direct expansion multipoise fan coils are designed to cover a wide range of air handling requirements. They are compact and ready to fit where needed in the basement, crawlspace, attic, utility room, or closet. All units come with solid-state power board controls, -in. insulation with an R value of 4.2, super-quiet multispeed motors, and fully wettable coils. Units can accommodate factoryor field-installed heaters from 3 to 30 kw. The FA4A is the residential new construction (RNC) model in the line-up. It is available with or without factory installed disconnects. It has an embossed galvanized steel casing, 2-speed motor in 08 through 036 sizes and 3-speed motor in 042 through 060 sizes. The FA4A is equipped with an AccuRater metering device. The FB4A is the standard of Carrier fan coils. It comes in a prepainted galvanized steel casing with foil-faced insulation and has a 3-speed motor in the full range of sizes 08 through 070. All units are equipped with an AccuRater metering device and are also shipped with a cleanable, permanent framed filter. The is the deluxe design in the fan coil group. It incorporates all the features found in the FB4A. In addition, it has a hard shut-off thermostatic expansion valve (TXV) metering device with internal check valves for reverse-flow bypass capability. The is available in sizes 024 through 070. Copyright 997 Carrier Corporation Form FA4A-6PD

2 Standard features Grooved copper tubing Lanced sine-wave aluminum fin Fully wettable coils High-impact thermoplastic condensate pan Primary and secondary drain connection with brass inserts Multipoise design for maximum versatility Field-installed heater packages from 3 30 kw (fused, circuit breaker, or non-fused) Control board with built-in, replaceable 5-amp blade-type auto fuse Cooling controls Time-delay relay (TDR) High-density, super thick R 4.2 insulation Sweat connections Inspection plate for cleaning A-coil design HUD approved for manufactured housing 40-va, 208/230-v transformer All models listed with UL, cul, ARI, and RADCO Additional features FA4A sizes available with and without factory installed disconnect Embossed galvanized steel cabinet Foil faced high density insulation 2-speed motor in 08 through 036 sizes 3-speed motor in 042 through 060 sizes AccuRater metering device Factory-installed heaters available FB4A sizes Prepainted galvanized steel cabinet 3-speed motor on all sizes 08 through 070 Modular version available in 042 through 070 sizes AccuRater metering device Foil-faced, high density insulation Factory-supplied, cleanable, permanent framed filter Factory-installed heaters available Factory-supplied power plug Multiple electric entry sizes TXV Prepainted galvanized steel cabinet 3-speed motor on all sizes 024 through 070 Modular version available in 054 through 070 sizes Foil-faced, high-density insulation Factory-supplied, cleanable, permanent framed filter Factory-supplied power plug Multiple electric entry 2

3 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH EQUIPMENT EQUIPMENT STANDARD STANDARD Model number nomenclature F C 4 B N F AEAA A Common Unit E Minor Engineering Change A Standard Unit A Standard Unit Electric Heater (kw) Nominal Capacity (Btu) 08 8, , , , , , , ,000 B Modular with in. Super Thick Insulation C Factory Installed Disconnects F Single Piece Cabinet with in. Super Thick Insulation F Fan Coil A RNC B Standard C Deluxe 4 Multipoise N 208/ A Original Series B Second Series HEAT PUMP UNITARY UNITARY AIR CONDITIONING 240 ARI ARI 20 CERTIFICATION LISTING TESTING INSPECTION CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. 3

4 Dimensions TOP VIEW 7 8 DIA KNOCKOUTS FOR LOW VOLTAGE CONTROL WIRING 7 8 NOTE: Series designation is the 4th position of unit model number C B , 3 32, 2 DIA KNOCKOUTS FOR HIGH VOLTAGE POWER WIRING NOTE: Allow 2 In. from front for service OUTLET AIR 7 8 DISCONNECT OR CIRCUIT BREAKER LOCATION BLOWER, CONTROL, & ELECTRIC HEATER ACCESS PANEL COIL ACCESS PANEL LIQUID LINE CONNECTION LIQUID LINE CONNECTION ALTERNATE 7 8 DIA KNOCKOUT FOR LOW VOLTAGE CONTROL WIRING INLET AIR ALTERNATE 7 8, 3 32, 2 DIA KNOCKOUTS FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE OPTIONAL FILED COPNVERTED RIGHT SIDE RETURN OPENING (SLOPE COIL UNITS ONLY) LIQUID LINE CONNECTION FITTING PANEL SUCTION LINE CONNECTION E A 4 6 NOTE: Modular units will have a two-piece cabinet. 2 J MAX. H FOR MODULAR UNITS OPENING D INLET AIR FRONT VIEW SHOWN WITH "A" COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR HORIZ APPLICATIONS FILTER ACCESS PANEL SUCTION LINE CONNECTION ACCESS PANEL CONFIG FOR SLOPE COIL DETAILS SLOPE COILS CONNECTION LOCATIONS DOWNFLOW OR HORIZ SHOWN FOR UPFLOW RIGHT APPLICATIONS OR HORIZ LEFT APPLICATIONS AND "A" COILS DOWNFLOW APPLICATIONS RIGHT SIDE VIEW INLET AIR OPENING 2 2 A95535 UNIT COIL A B C D E H J SIZE* E In. mm In. mm In. mm In. mm In. mm In. mm In. mm 08, 024 Slope 42-/ / / / / Slope 47-/ / / / / Slope 49-5/ / / / / Slope 53-7/ / / / / / A 49-5/ / / / / / , 060 A 53-7/ / / / / / , 070 A 59-3/ / / / / / * Descriptions and dimensions apply to all versions (FA4A, FB4A, and ), unless otherwise specified. Applicable for modular units only. 4

5 Dimensions continued SLOPE COIL AIRFLOW 7 6 (4 PLACES)* AIRFLOW (2 PLACES)* PRIMARY DRAIN SECONDARY DRAIN SECONDARY DRAIN 3 6 * PRIMARY DRAIN (2 PLACES)* F G 5 6 * SECONDARY DRAIN PRIMARY DRAIN * (2 PLCS) SECONDARY DRAIN PRIMARY DRAIN 2 * 7 8 * HORIZ LEFT (AS SHIPPED) * * HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM, HOLES PROVIDED.36 IN. DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. PRIMARY DRAIN SECONDARY DRAIN 3 6 * 6 SECONDARY DRAIN PRIMARY DRAIN UPFLOW (AS SHIPPED) AIRFLOW (2 PLACES)* (4 PLACES)* (2 PLACES)* F /6 (4 PLACES)* DOWNFLOW (FIELD CONVERTED) AIRFLOW 3 6 * (2 PLACES)* G 5 6 * 2 F SECONDARY DRAIN * 6 HORIZ RIGHT (FIELD CONVERTED) PRIMARY DRAIN SECONDARY DRAIN 7 8 * PRIMARY DRAIN (2 PLACES)* 7 8 * 2 * 4 HORIZ LEFT (AS SHIPPED) * (2 PLACES)* UPFLOW (AS SHIPPED) (4 PLACES)* 3 6 * 4 2 HORIZ RIGHT (FIELD CONVERTED) 2 * 7 8 * A COIL A DOWNFLOW (FIELD CONVERTED) UNIT SIZE* COIL E F G In. mm In. mm 08, 024 Slope 8-/ / Slope 23-/ / Slope 23-/ / Slope 26-5/ / A 23-7/ / , 060 A 27-/ / , 070 A 32-5/ / * Descriptions and dimensions apply to all versions (FA4A, FB4A, and ), unless otherwise specified. 5

6 Physical data MODEL FA4A FB4A * SHIPPING WT (Lb) FA FB/FC REFRIGERANT METERING DEVICE Bypass AccuRater (FA4A, FB4A); TXV Factory Installed on PISTON SIZE TXV SIZE 2 ton 2-/2 ton 3 ton 3 ton 4 ton 3 ton 5 ton 4 ton 5 ton COIL Rows and Fins Per In. 2 and and and and and and and and and and 4.5 Face Area (Sq Ft) Configuration Slope Slope Slope Slope Slope A A A A A FAN Air Discharge CFM (Nominal) Motor Hp (PSC) /5** /4 /3** /3 /2 3/4 /3 3/4 /2 3/4 FILTER 2-/2 x 3 2-/2 x 6-3/8 2-/2 x 9-7/8 2-/2 x 23-5/6 * Fan coil units with hard shut-off TXV may require compressor hard start components. Refer to outdoor unit specifications. factory-installed TXV is hard shut-off, bypass flow-type for heat pump application. Filter must be field supplied for FA4A units. (See Accessory Kits.) ** FA4A08 fan coil has a /0 Hp motor FA4A030 fan coil has a /4 Hp motor NOTE: Descriptions and dimensions apply to all versions (FA4A, FB4A,, etc.), unless otherwise specified. 6

7 Performance data MODEL AND SIZE FA4A 08 FB4A 08 FA4A 024 FB4A, 024 FA4A 030 FB4A, 030 FA4A 036 FB4A, 036 FA4A, FB4A, 042 FA4A, FB4A, 048 FA4A, FB4A, 060 FB4A, AIRFLOW PERFORMANCE (CFM) EXTERNAL STATIC PRESSURE (IN. WC) BLOWER MOTOR SPEED 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V High Low High Medium Low High Low High Medium Low High Low High Medium Low High Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low NOTES:. Airflow based upon dry coil at 230v with factory approved filter and electric heater (2 element heater, sizes 08 through 036; 3 element heater, sizes 042 through 060). 2. Not recommended for use above 0.60 in. external static pressure. Airflows in this region have the potential for condensate to blow out of the drainpan. If usage in this region is desired, consult duct static pressure graph for allowable return and supply duct static pressures. Airflows in this region are outside recommended airflow for all applications. Usage at these airflows could result in condensate blowing out of the drainpan. 7

8 TOO HIGH TOTAL STATIC PRESSURE (AIRFLOW TOO LOW) SUPPLY STATIC PRESSURE, IN.W.C ACCEPTABLE RANGE TOO HIGH RETURN STATIC PRESSURE (DIFFICULT TO MAKE TRAP) 0. TOO HIGH AIRFLOW* (WATER MAY BLOW OUT OF PAN PRIOR TO MAKING TRAP] RETURN STATIC PRESSURE, IN.W.C. A96027 ACCEPTABLE DUCT CONDITIONS For satisfactory operation (specifically making dry secondary trap), subject fan coils must be installed witth duct systems which fall within the Acceptable Range illustrated above. * Operation in this Too High Airflow range (below 0.2 supply static) applies only to horizontal applications of the following: All other applications (the above units on low speed. FK units, 08 thru 042 units, all units in vertical applications, etc.) are acceptable to use below the 0.2 supply static boundary. 048 medium and high blower speeds 060 medium and high blower speeds 070 high blower speeds 8

9 Performance data continued * Indicates medium speed (blue). All other motor speeds at low tap. MINIMUM CFM AND MOTOR SPEED SELECTION FAN COIL SIZES HEATER KW FA, FB, FC * * * 036, , , FILTER STATIC PRESSURE DROP (IN. WC) UNIT CFM SIZE , 038, , ELECTRIC HEATER STATIC PRESSURE DROP (IN. WC) HEATER ELEMENTS EXTERNAL STATIC PRESSURE CORRECTION KW , , , HEATER ELEMENTS EXTERNAL STATIC PRESSURE CORRECTION KW , , , 24, 30.0 The airflow performance data was developed using fan coils with 0-kw electric heaters (2 elements) in the 08 through 036 size units and 5-kw heaters (3 elements) in the 042 through 070 size units. For fan coils with heaters of a different number of elements, the external available static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN. WC) AT INDICATED AIRFLOW (DRY-TO-WET COIL) UNIT CFM SIZE NOTE: UNIT CFM SIZE , , , Subtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system. 9

10 Performance data continued UNIT FA4A, FB4A 08 FA4A, FB4A, 024 FA4A, FB4A, 030 FA4A, FB4A, 036 FA4A, FB4A, 042 FA4A, FB4A, 048 See notes on pg.. EVAPORATOR AIR CFM AND BF GROSS COOLING CAPACITIES (MBH) COIL REFRIGERANT TEMPERATURE ( F)* Evaporator Air Entering Wet-Bulb Temp ( F)

11 UNIT FA4A, FB4A , 060 FB4A , 070 EVAPORATOR AIR CFM AND BF * Saturated suction leaving evaporator coil. Sensible Heat Capacity (000 Btuh) BF Bypass Factor NOTES:. Contact manufacturer for cooling capacities at conditions other than shown in table. 2. Formulas: sensible heat cap. Leaving db = entering db.09 x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (h lwb ) h lwb = h ewb total capacity (Btuh) 4.5 x CFM where h ewb = enthalpy of air entering coil. 3. Direct interpolation is permissible. Do not extrapolate. GROSS COOLING CAPACITIES (MBH) continued COIL REFRIGERANT TEMPERATURE ( F)* Evaporator Air Entering Wet-Bulb Temp ( F) SHC is based on 80 F db temperature of air entering coil. Below 80 F subtract (corr factor x CFM) from SHC. Above 80 F db, add (corr factor x CFM) to SHC. BYPASS FACTOR SHC CORRECTION FACTOR ENTERING AIR DRY-BULB TEMPERATURE ( F) Under Over 85 Correction Factor Interpolation is permissible. Correction Factor =.09 x ( BF) x (db 80) Use formula shown below Carrier accessories ITEM ACCESSORY PART NO.* FAN COIL SIZE USED WITH Disconnect Kit KFADK00DSC Cooling controls and heaters 3 kw through 0 kw Downflow Base Kit KFACB00CFB 08, 024 KFACB020CFB 030, 036 KFACB030CFB 038, 042, 048, 060 KFACB040CFB 054, 070 Downflow Conversion Kit KFADC020SLP Slope Coil Units 08, 024, 030, 036, 042 KFADC040ACL A-Coil Units 038, 048, 054, 060, 070 Single-Point Wiring Kit KFASP00SPK 5 and 20 kw Fused Heaters Filter Kit (2 Pack) KFAFK02SML 08, 024 KFAFK022MED 030, 036 KFAFK032LRG 038, 042, 048, 060 KFAFK042XXL 054, 070 Power Plug Kit (25 Pack) KFAPP025PLG FA4A * Factory-authorized and listed, field installed.

12 Accessory Kits Description Suggested and Required Use. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: FC4, FB4, and FA4 units for 3kw through 0kw electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a -in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap free seal with the floor. REQUIRED USE: This kit must be used whenever FC4, FB4, and FA4 fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A-coils. REQUIRED USE: This kit must be used whenever FC4, FB4, and FA4 fan coils are used in downflow applications. 4. Single Point Wiring Kit The single point wiring kit acts as a jumper between L and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run 2 heavy-gage, highvoltage wires into the fan coil rather than 4 light-gage, high-voltage wires. SUGGESTED USE: FC4, FB4, and FA4 fan coils only with 5kw and 20kw heaters. 5. Fan Coil Filter The kit consists of 2 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and in turn the efficiency of the system. SUGGESTED USE: To replace filters in FC4, FB4, and FA4 fan coils. REQUIRED USE: All FA4A units unless a filter grille is used. 6. Power Plug Kit The kit consists of 25 wire harness assemblies. Each plug provides the high-voltage power connection to the fan coil in the absence of electric heat. REQUIRED USE: FA4A units installed without electric heat. Accessory electric heaters Smart heat 2 FACTORY INSTALLED HEATER OPTIONS MODEL FA4ANF 5, 8, 0 5, 8, 0 5, 8, 0, 5 5, 8, 0, 5 8, 0, 5 8, 0, 5 0 FA4ANC 5, 8, 0 5, 8, 0 5, 8, 0 5, 8, 0 8, 0 8, 0 0 FB4ANF 5, 8, 0 5, 8, 0 5, 8, 0, 5 5, 8, 0, 5 8, 0, 5 8, 0, 5 0 HEATER PART NO. 240V VOLTS/PH KW/STAGE INTERNAL CIRCUIT PROTECTION FAN COIL SIZE USED WITH HEATING 230V KFAEH00N / 3 None ,400 KFAEH020N / 5 None ,700 KFAEH030N / 8 None ,00 KFAEH040N / 0 None ,400 KFAEH060F / 0, 0 Fuse ,800 KFAEH /3 5, 0 None ,00 KFAEH /3 6, 6, 6 None ,500 KFAEH00F /3* 8, 8, 8 Fuse 048, 060, ,300 KFAEH0F /3* 0, 0, 0 Fuse 048, 060, ,00 KFAEH30C / 5 Circuit Breaker ,700 KFAEH40C / 8 Circuit Breaker ,00 KFAEH50C / 0 Circuit Breaker ,400 KFAEH70C / 0, 0 Circuit Breaker ,800 KFAEH90S / 0, 0 Fuse ,800 KFAEH250N / 3, 6 None ,200 KFAEH260F / 5, 0 Fuse ,00 KFAEH270S / 5, 0 Fuse ,00 KFAEH280C / 5, 0 Circuit Braker ,00 HEATER PART NO. 240V VOLTS/PH KW/STAGE INTERNAL CIRCUIT PROTECTION FAN COIL SIZE USED WITH HEATING 230V KFAEH220H / 4, 6 None ,400 KFAEH230H / 3, 8, 4 Fuse ,00 KFAEH240H / 5, 0, 5 Fuse ,800 * Field convertible to phase. Field convertible to 3 phase. Approved for Canadian application. ** Blower motor heat not included. When using units with 20-, 24-, and 30-kw electric heaters, maintain a -in. clearance from combustible materials to discharge plenum and ductwork and maintain a distance of 36 in. from the unit. Use an accessory downflow base to maintain proper clearance on downflow installations. Use flexible connectors between ductwork and unit to prevent transmission of vibration. When electric heater is installed, use heat resistant material for flexible connector between ductwork and unit at discharge connection. Ductwork passing through unconditioned space must be insulated and covered with vapor barrier.

13 UNIT SIZE VOLTS ( PHASE) FLA FAN COIL ELECTRICAL DATA (UNITS WITHOUT ELECTRICAL HEAT) MIN CKT AMPS Min Wire Size* Awg BRANCH CIRCUIT Max Wire Length (Ft) / / / , / , / / , / * Use copper wire only. Use 75 C only in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60 C conductors, instead of wire sizes shown in table above per NEC 996 Article Length shown is as measured one way along wire path between unit and service panel for a voltage drop not to exceed 2%. FLA Full Load Amps 208v 230v Fuse Amps HEATER KW ELECTRIC HEATER INTERNAL PROTECTION PHASE FUSE QTY/SIZE CKT BKR QTY/SIZE 3 5 /60 8 /60 0 /60 5 2/30 2/60 2/ /60 2/ / / 0 9 / CONDITIONS ESTIMATED SOUND POWER LEVEL OCTAVE BAND CENTER FREQUENCY* UNIT Ext Static Motor SIZE CFM Pressure Rpm , , , * Estimated sound power levels have been derived using the method described in the 987 ASHRAE HVAC Systems & Applications Handbook, Chapter 52, p

14 ELECTRIC HEATER ELECTRICAL DATA BRANCH CIRCUIT HEATER KW INTERNAL CIRCUIT PART NO. 240V 208V PHASE PROTECTION CIRCUIT L, L2 L3, L4 CIRCUIT L, L2 L3, L4 CIRCUIT L, L2 L3, L4 CIRCUIT L, L2 L3, L4 CIRCUIT L, L2 L3, L4 KFAEH00N None 0.9/ /7.5 2/2 2/2 20/20 63/65 KFAEH020N None 8./ / /30 8/85 KFAEH020N None 8./ / /40 8/85 KFAEH30C Ckt Bkr 8./ / /30 8/85 KFAEH30C Ckt Bkr 8./ / /40 8/85 KFAEH030N / / /50 2 KFAEH40C / / /50 2 KFAEH250N09 *** / /5.9 50/60 94/96 3 KFAEH040N0 KFAEH50C0 KFAEH260F5*** KFAEH270S5*** KFAEH280C5*** KFAEH08035 KFAEH09038 KFAEH060F20 KFAEH70C20 KFAEH90S None Ckt Bkr None None None Ckt Bkr Fuse Fuse* Ckt Bkr None None Fuse Ckt Bkr Fuse* 8.8/ / / / / / /79.9 HEATER AMPS 208/230V 8./ / / / / / / / / / / /06.8 MIN AMPACITY 208/230V** 52.2/ / / / / / / / / / / /50.0 MIN WIRE SIZE (AWG) 208/230V 4/4 4/4 8/6 3/2 3/2 MIN GND WIRE SIZE 208/230V FUSE/CKT BKR AMPS 208/230V 35/35 60/60 60/60 80/90 80/90 50/50 60/60 00/0 00/0 60/60 25/25 60/60 25/25 60/60 25/25 60/60 50/50 60/60 60/60 50/50 50/50 MAX. WIRE LENGTH 208/230V (FT) CIRCUIT L, L2 L3, L4 08/ 86/87 86/87 7/2 94/95 84/06 84/06 58/58 58/58 58/58 KFAEH00F24 *** KFAEH0F30 *** Fuse Fuse Fuse Fuse 50./ / / / / / / /4 / 3/3 0/00 80/80 25/50 90/00 50/75 6/7 2/3 20/2 4/45 SMART HEAT ELECTRICAL DATA BRANCH CIRCUIT HEATER PART NO. KFAEH220H0 KFAEH230H5 KFAEH240H20 HEATER AMPS 208/230V MIN AMPACITY 208/230V** MIN WIRE SIZE (AWG) 208/230V MIN GND WIRE SIZE 208/230V FUSE/CKT BKR AMPS 208/230V MAX. WIRE LENGTH 208/230V (FT) KW INTERNAL CIRCUIT 240V 208V PHASE PROTECTION CIRCUIT L, L2 L3, L4 CIRCUIT L, L2 L3, L4 CIRCUIT L, L2 L3, L4 CIRCUIT L, L2 L3, L4 CIRCUIT L, L2 L3, L4 CIRCUIT L, L2 L3, L None 32.5/ / /50 0/ Fuse 54.2/ / / / / /26.8 4/4 80/90 50/60 30/30 90/9 9/9 69/ Fuse 72.3/ / / /50.0 3/2 00/0 60/60 50/50 84/06 58/58 FIELD MULTIPOINT WIRING OF 24- AND 30-KW PHASE HEATER PART NO. KFAEH00F24 KFAEH0F30 HEATER AMPS MIN AMPACITY MIN WIRE SIZE (AWG) KW MIN GND FUSE/CKT BKR AMPS MAX. WIRE LENGTH 208/230V 208/230V** 208/230V WIRE SIZE 208/230V 208/230V (FT) 240V 208V PHASE L,L2 L3,L4 L5,L6 L,L2 L3,L4 L5,L6 L,L2 L3,L4 L5,L6 208/230V L,L2 L3,L4 L5,L6 L,L2 L3,L4 L5,L / / / / / / / / / /50 60/60 40/45 50/60 40/45 50/ /73 58/58 73/73 58/58 NOTE: * ** Approved for Canadian application. Field convertible to phase, single or multiple supply circuit. Field convertible to 3 phase. Includes blower motor amps of largest fan coil used with heater. Copper wire must be used. If other than uncoated (non-plated), 75 C ambient, copper wire (solid wire for 0 AWG and smaller, stranded wire for larger than 0 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). Length shown is as measured way along wire path between unit and service panel for a voltage drop not to exceed 2%. *** Heaters are smart capable when used with the FK fan coil and corporate 2-speed programmable thermostat (TSTATXXP2S0-A).. For fan coil sizes For fan coil sizes Single circuit application of F5 and F20 heaters requires single-point wiring kit accessory. A

15 Matched system OUTDOOR UNIT HUMIDIFIER FAN COIL AIR FLOW ELECTRONIC AIR CLEANER A9646 5

16 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG [ ] Packaged Service Training [ ] Classroom Service Training A94328 Copyright 997 Carrier Corporation Indianapolis, IN Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 4 Page 6 Catalog No FA-4A7C Printed in U.S.A. PC 0 Form FA4A-6PD Tab 3d 2e Replaces: FA4A-5PD

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR:

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

Product Data. FX4C, FC4D Comfort Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FX4C, FC4D Comfort Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST , Comfort Series Fan Coil Sizes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST The and the fan coils combine the proven technology of Carrier fan coil units with either Puron, the environmentally

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil

More information

FEM4X, FSM4X, FSU4X. Product Specifications

FEM4X, FSM4X, FSU4X. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT, FSU4X Product Specifications FAN COILS ALL MODELS Available for Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin

More information

FMU4X, FMC4X FMU4Z, FMC4Z

FMU4X, FMC4X FMU4Z, FMC4Z HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,

More information

EBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES. Model Number

EBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES. Model Number ENVIRONMENTALLY SOUND REFRIGERANT EBP Product Specifications EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES Multipoise design for maximum versatility 2 speed motor in 24 and 36 sizes 3 speed motor in

More information

135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944)

135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944) ENVIRONMENTALLY SOUND REFRIGERANT Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for Environmentally Sound R 410A systems Bolt

More information

STANDARD FEATURES S S S S S S S S S S S S S S S S S S S S S S S S

STANDARD FEATURES S S S S S S S S S S S S S S S S S S S S S S S S TANDARD FEATURE Multi -tap ECM (electronic commutating motor) motors - all sizes Integrated motor controls, with 90 -sec off TDR function, have replaced integrated circuit board Five available speed tags

More information

Dimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT

Dimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT ENVIRONMENTALLY SOUND REFRIGERANT B Series Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two--stage outdoor units Available for Environmentally Sound R--410A systems

More information

FEM4P, FSM4P, FSU4P. Product Specifications

FEM4P, FSM4P, FSU4P. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P, FSU4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering

More information

CFM Range Tons x 21 1 / 8 x x 21 FVM*X4800A 48, FVM*X6000A 60, x 24 x x

CFM Range Tons x 21 1 / 8 x x 21 FVM*X4800A 48, FVM*X6000A 60, x 24 x x FVM Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for R 22 or Environmentally Sound R 410A systems Bolt on, hard shut off TXV

More information

FEM, FSM, FSU. Product Specifications FAN COILS

FEM, FSM, FSU. Product Specifications FAN COILS FEM, FSM, FSU Product Specifications FAN COILS ALL MODELS 1½ thru 5 tons Available for R 22 or Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin coil

More information

FEM, FSM, FSU. Product Specifications

FEM, FSM, FSU. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS ALL MODELS 1½ thru 5 tons Available for R 22 or Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin coil Sweat

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.   DESCRIPTION FEATURE TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.     DESCRIPTION TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information

Typical Applications. Horizontal Installation

Typical Applications. Horizontal Installation ENGINEERING DATA COILS COIL UNITS CB19 AND CBH19 SERIES UP-FLOW, DOWN-FLOW AND HORIZONTAL COIL UNITS *12,600 to 65,500 Btuh (3.7 to 19.2 kw) Cooling Capacity 11,500 to 60,000 Btuh (3.4 to 17.6 kw) Heat

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

ELECTRIC HEAT AIR HANDLERS

ELECTRIC HEAT AIR HANDLERS ELECTRIC HEAT AIR HANDLERS 208/230V 1 1 /2 to 5 TONS High efficiency series for R-22 Certain models feature GE s new X-13 motor for enhanced SEER performance with most outdoor condensing units Multi-position

More information

Product Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 13 SEER Features/Benefits One-piece

More information

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

MERIT Series R-410A - Upflow / Horizontal - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING (598) STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING HEAT PUMP S: F2RP / F2FP018 THRU 060 COOLING S: F2RC / F2FC018 THRU 036 VARIABLE SPEED : F2FV060 DESCRIPTION This fan coil

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

Installation Instructions

Installation Instructions Installation Instructions Downflow Conversion Kit KFADC NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS

More information

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY PRODUCT SPECIFICATIONS APPLICATION 2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (11/2018) INSTALLATION One piece design Smaller profile for closet

More information

FORM NO. HSC-543 AIR HANDLERS

FORM NO. HSC-543 AIR HANDLERS FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES TECHNICAL GUIDE MODELS: N*AH Modular Air Handlers For use w / Split System Cooling & Heat Pump 600-2000 CFM Blowers 2-5 Ton Coils Optional 1 & 3 Electric Heaters DESCRIPTION This unique modular system

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler /RHT- Series Constant Torque (ECM) Efficiencies up to 16 SEER /RHT feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60 TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous

More information

N4A4 C. Product Specifications

N4A4 C. Product Specifications COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier

More information

Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number *

Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number * COMMERCIAL PAE Product Specifications Ashrae 90. EFFICIENCY PACKAGE A/C UNIT - 80 to 232 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual,

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency

More information

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit

More information

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification

More information

Ruud High Efficiency Air Handler

Ruud High Efficiency Air Handler Air Handlers Ruud High Efficiency Air Handler RHLL- Series X-1 (ECM) Efficiencies up to 16 SEER RHLL feature an X-1 (ECM) motor which provides enhanced SEER performance with most Ruud outdoor units. Versatile

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806 TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS HEAT PUMP MODELS: F2RP/F2FP018 THRU 060 F3RP/F3FP018 THRU 060(T) FXRP024 THRU 060 COOLING MODELS F2RC/F2FC024 THRU

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: 15SEERSplitHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal

More information

TSA6. Product Specifications. SmartComfort TXC 5600

TSA6. Product Specifications. SmartComfort TXC 5600 ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230

More information

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal

More information

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

Product Data. 42D Ducted Fan Coil Air Conditioners cfm Product Data 42D Ducted Fan Coil Air Conditioners 600-2000 cfm Carrier s 42D series ducted fan coil units offer design and equipment location flexibility Choice of 5 models, each available in 8 sizes For

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY PRODUCT SPECIFICATIONS APPLICATION 1 1/2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (12/2018) INSTALLATION 1 piece design Smaller profile for

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHLP- Standard Efficiency X-13 (ECM) Motor RHLP features an X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 1 1 /2 ton [.3 kw] through

More information

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) TECHNICAL SPECIFICATIONS HMG*T Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG*T series of air handlers, when combined with our heat pump or air conditioner, offer

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) TECHNICAL SPECIFICATIONS HMG Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG Series of air handlers, when combined with our heat pump or air conditioner,

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: PH13PA 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design

More information

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh TECHNICAL SPECIFICATIONS P3R(A,C) Series Single Packaged Air Conditioner, Single Phase P3RA-10 SEER 2 thru 5 Ton Units Cooling: 24,000 to 59,000 Btuh P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800

More information

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) TECHNICAL GUIDE TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE S: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) LISTED Due to continuous product improvement, specifications are subject

More information

Product Data. FX4C (50 Hz) Direct Expansion Fan Coil Sizes 024 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FX4C (50 Hz) Direct Expansion Fan Coil Sizes 024 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST FX4C (50 Hz) Direct Expansion Fan Coil izes 024 thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The FX4C fan coil is the latest in air handling technology. It s the one to choose for high efficiency

More information

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on

More information