Product Data. FX4C (50 Hz) Direct Expansion Fan Coil Sizes 024 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST
|
|
- Rosalyn Hunter
- 5 years ago
- Views:
Transcription
1 FX4C (50 Hz) Direct Expansion Fan Coil izes 024 thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The FX4C fan coil is the latest in air handling technology. It s the one to choose for high efficiency operation, application versatility, ease of installation, and high -tech performance. FX4C fan coils are encased, 1 -piece units, designed for vertical (upflow or downflow) and horizontal installations. Downflow installations require an accessory adapter package. The FX4C is compact, designed for upflow, downflow, and horizontal installations, and ready to fit right where you need it. The solid construction of the pre -painted metal cabinet ensures years of rugged service, and it s packed with the most advanced components so you know it s going to perform like a deluxe fan coil should. Inside, you ll find grooved tube/lanced fin coils. olid -state cooling controls are included with every unit. Efficient and dependable metering of the refrigerant is provided by our AccuRater, a device which improves overall system reliability and is easily accessible for piston changeout and routine maintenance. Carrier also engineered the FX4C with dedicated refrigerant circuitry, and high -density insulation. For leak -free connections, the FX4C is equipped with sweat connections. The FX4C offers superior versatility with its -speed PC motor. Electric heaters are not offered as accessories for CE mark units. Compact and attractive with a low -maintenance, easy -to -clean, permanent filter, the FX4C is a favorite for contractors and homeowners. Just consider the first -cost affordability and Carrier performance and it s easy to see why it s the fan coil of choice. A10082
2 TANDARD FEATURE 4 models available All units multipoise install upflow, horizontal, or downflow Unique cabinet design that meets new stringent regulations for air leakage. Meets requirements of a 2% cabinet leakage rate when tested at 25 mm of static pressure Grooved tubes Lanced sine wave aluminum fins Fully wettable coil Cooling controls on every unit 40va control power transformer Replaceable 5 -amp blade -type automotive fuse protects against transformer secondary short olid -state control board -speed motor Easy access filter for cleaning no tools required Newly improved filter rack area filter door insulation added for an improved air seal Prepainted galvanized steel sheetmetal High -density insulation weat connections AccuRater piston Multiple electric entry Reinforced plastic condensate pan with brass drain connection inserts econdary drain connection 2
3 NOMENCLATURE CHART CARRIER FAN COIL , 8, 9 10, 11, F X 4 C X A A A A Product eries Type Position Major eries Electrical Cabinet/Insulation Nominal Capacity (Btu) Coil Type Variations F = Fan Coil x = R410---A 4 = Multipoise C = 20v 1ph---50hz X=Exportwith CE Mark 024 = 24, = 6, = 48, = 60, Copper L Aluminum Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to IP20
4 DIMENION 7/8", 1 /2" 2" DIA. K.O.'s FOR HIGH VOLTAGE POWER WIRING 7/8" DIA. K.O. 1 7/8" FOR LOW VOLTAGE CONTROL WIRING 1 15/16" TOP VIEW NOTE: NOTE: ALLOW 21" FROM FRONT 1" 1. ERIE DEIGNATION I THE 14TH POITION FOR ERVICE. OF UNIT PRODUCT NUMBER. 1 /8" 22 1/16" 10 /16" 11" 7/8" B 1" /4" 2 1/8" 15/16" OUTLET AIR C DICONNECT OR CIRCUIT BREAKER LOCATION ALTERNATE UNIT CONNECTION IZE BLOWER, CONTROL, 7/8", 1 /2", 2" DIA. K.O.' & ELECTRIC HEATER FOR HIGH VOLTAGE UCTION: 024-5/8" I.D. WEAT ALTERNATE ACCE PANEL POWER WIRING 06 - /4" I.D. WEAT 7/8" DIA. K.O. OPPOITE IDE 048 & 060-7/8" I.D. WEAT FOR LOW VOLTAGE LIQUID: /8" I.D. WEAT CONTROL WIRING CONDENATE: /4" FIT OPTIONAL FIELD CONVERTED RIGHT IDE RETURN OPENING INLET AIR (LOPE COIL UNIT ONLY) COIL ACCE A 1 1/2" PANEL 2 5/8" 4 11/16" E FITTING LIQUID LINE LIQUID LINE CONNECTION LIQUID LINE PANEL 1/16" CONNECTION CONNECTION UCTION LINE CONNECTION 1 /16" J MAX 19" 10 7/16" UCTION LINE 10 /4" CONNECTION 6 /16" 9 1/2" 1 /4" 5" FILTER ACCE PANEL OPENING 1" D INLET AIR FRONT VIEW HOWN WITH "A" COIL DETAIL CONNECTION LOCATION FOR UPFLOW OR HORIZ. APPLICATION LOPE COIL DETAIL CONNECTION LOCATION HOWN FOR UPFLOW OR HORIZ. LEFT APPLICATION OPENING ACCE PANEL CONFIG. FOR 1 1/4" 19 1/16" 2 1/2" LOPE COIL RIGHT IDE VIEW DOWNFLOW OR HORIZ. RIGHT APPLICATION INLET AIR AND "A" COIL DOWNFLOW APPLICATION A04165 UNIT IZE COIL TYPE A B C D J IN. MM IN. MM IN. MM IN. MM IN. MM 024 lope / / / / lope 5---7/ / / / A / / / / A 5---7/ / / /
5 DIMENION (CONT.) A0229 UNIT IZE COIL TYPE F G IN. MM IN. MM 024 lope 2---1/ / lope / / A 2---7/ / A / /
6 UNIT IZE 024 PHYICAL DATA NOMINAL CAPAC TR KILOWATT * OPERATING WEIGHT KG DIMENION (VERT) HEIGHT WIDTH DEPTH REFRIGERANT REFRIG CONTROL UNIT ARRANGEMENT MM MM MM R-22 Bypass AccuRater Upflow/Downflow/Horizontal (LH) FAN AIRFLOW/NOM. L/ MOTOR TYPE NOMINAL KW PC PEED RPM 1000/900/800 INDOOR COIL Copper Tube / Aluminum Tube / Aluminum Fin with Lanced ine Wave FACE AREA Q M ARRANGEMENT lope lope A A ROW FIN DENITY /M FILTER Permanent Type/25 mm (1 in.) Thick COIL CONNECTION VAPOR (OD) IN LIQUID (OD) IN * Based on nominal airflow rates, 19.4 C entering wet bulb and 7.2 C sat suction temp. weat-type METRIC A14210 UNIT IZE 024 NOMINAL CAPAC TR BTU/HR ** OPERATING WEIGHT LB DIMENION (VERT) HEIGHT WIDTH DEPTH REFRIGERANT REFRIG CONTROL UNIT ARRANGEMENT IN. IN. IN / /8 22-1/ / /8 22-1/16 R-22 Bypass AccuRater / /8 22-1/16 Upflow/Downflow/Horizontal (LH) ENGLIH / /8 22-1/16 FAN AIRFLOW/NOM. CFM MOTOR TYPE NOMINAL HP 1/ 1/ PC /4 / 4 PEED RPM 1000/900/800 INDOOR COIL Copper Tube / Aluminum Tube /Aluminum Fin with Lanced ine Wave FACE AREA Q FT ARRANGEMENT ROW FIN DENITY /IN. lope 14-1/2 lope 14-1/2 A 14-1/2 A 14-1/2 FILTER Permanent Type/25 mm (1 in.) Thick COIL CONNECTION weat-type VAPOR (OD) IN. 5/8 /4 LIQUID (OD) IN. /8 /8 ** Based on nominal airflow rates, 67 F entering wet bulb and 45 F sat suction temp. 7/8 /8 7/8 /8 A
7 UNIT IZE L/ BPF PERFORMANCE DATA COOLING CAPACITIE (Kw) COIL REFRIGERANT TEMPERATURE* ( C) METRIC Evaporator Air Entering Wet-Bulb Temp ( C) TC C TC C TC C TC C TC C TC C TC C TC C TC C TC C TC C TC C LEGEND L/ Liters per second BF Bypass factor ensible heat capacity (kw) 1. Gross capacities shown do not include a deduction for evaporator fan motor heat. 2. Direct interpolation is permissible. Do not extrapolate.. HC is based on 26.7 C temperature of air entering the indoor unit. At any other temperature, correct the HC read from the table of cooling capacities as follows: Corrected HC KW = HC + [1.2 x 10 x (1-BF) x (Cdb-26.7) x L/s] Observe the rule of signs. Above 26.7 C, HC correction will be positive; add it to HC. Below 26.7 C, HC correction will be negative; subtract it from HC. 4. Formula: HCkW Cldb = Cedb 1.2 x 10 x (L/s) Leaving wet bulb = wet bulb temperature corresponding to enthalpy of air leaving coil (hlwb). TCkW hlwb = hewb 1.20 x 10 x (L/s) Where hewb is enthalpy of air entering evaporator coil (kj/kg). Airflow Performance, Airflow Rate - L/s UNIT IZE BLOWER MOTOR PEED EXTERNAL TATIC PREURE (PA) HIGH MED LOW HIGH MED LOW HIGH MED LOW HIGH MED LOW NOTE: Fan performance based on wet coil with factory-supplied filter; no internal heaters. Not recommended for use above 150 Pa external static pressure. A14205 METRIC A
8 UNIT IZE CFM BF PERFORMANCE DATA (CONT.) COOLING CAPACITIE (MBtuh) COIL REFRIGERANT TEMPERATURE* ( F) ENGLIH Evaporator Air Entering Wet-Bulb Temp ( F) TC C TC C TC C TC C TC C TC C TC C TC C TC C TC C TC C TC C LEGEND BF Bypass factor CFM Cubic Feet per Minute TC Total Capacity, 1000 Btu/hr C ensible Capacity, 1000 Btu/hr 1. Gross capacities shown do not include a deduction for evaporator fan motor heat. 2. Direct interpolation is permissible. Do not extrapolate.. HC is based on 80 F db temperature of air entering the indoor unit. At any other temperature, correct the HC read from the table of cooling capacities as follows: Corrected HC Btu/h = HC + [1.10 x (1-BF) + (Fdb-80) x cfm] Observe the rule of signs. Above 80 F, HC correction will be positive; add to it HC. Below 80 F, HC correction will be negative; subtract it from HC. 4. Formula: HCBtu/h Fldb = Fedb 1.10 x (cfm) Leaving wet bulb = wet bulb temperature corresponding to enthalpy of air leaving coil (hlwb). TCBtu/h hlwb = hewb 4.50 x (cfm) Where hewb is enthalpy of air entering evaporator coil (Btu/pound). A
9 Airflow Performance, Airflow Rate - CFM UNIT IZE BLOWER MOTOR PEED PERFORMANCE DATA (CONT.) NOTE: Fan performance based on wet coil with factory-supplied filter; no internal heaters. Not recommended for use above 0.60-in. wg external static pressure. EXTERNAL TATIC PREURE In. wc ENGLIH HIGH MED LOW HIGH MED LOW HIGH MED LOW HIGH MED LOW ACCEORIE A14207 ITEM ACCEORY PART NO.* FAN COIL IZE UED WITH 1. Disconnect Kit KFADK0201DC ALL 2. Downflow Base Kit KFACB0201CFB 024 KFACB001CFB 06, 048, 060. Downflow Conversion Kit KFADC0201LP lope Coil Units 024, 06 KFADC0401ACL A--- Coil Units 048, ingle--- Point Wiring Kit KFAP0101PK Only with and kw Fused Heaters 5. Filter Kit (12 Pack) KFAFK0212MED 024 KFAFK012LRG 06, 048, PVC Condensate Trap Kit (50 pack) KFAET0150ETK All 7. Air Cleaner volt Conversion Kit KEAVC All 8. Downflow/Horizontal Conversion Gasket Kit KFAHD0101LP All 9. Horizontal Water Management Kit (25 pack) KFAHC0125AAA All 10. tandard Filter Rack Kit KFAFR0201FRM 024 KFAFR001FRM 06, 048, 060 * Factory authorized and listed, field---installed. Accessory Kits Description uggested and Required Use. 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. UGGETED UE: Units for - through 10 -kw electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1 -in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap -free seal with the floor. REQUIRED UE: This kit must be used whenever fan coils are used in downflow applications.. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. eparate kits are available for slope coils and A -coils. REQUIRED UE: This kit must be used whenever fan coils are used in downflow applications. 4. ingle Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L lugs, and between the L2 and L4 lugs. This allows the installer to run two heavy -gauge, high -voltage wires into the fan coil rather than 4 light-gauge, high -voltage wires. UGGETED UE: Fan coils with 15 - and 20 -kw fused heaters only. 5. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. UGGETED UE: To replace filters in fan coils. REQUIRED UE: All units unless a filter grille is used. 6. Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps. Each trap is pre-formed and ready for field installation. This deep trap helps the system make and hold proper condensate flow even during blower initiation. UGGETED UE: All fan coils. 9
10 ACCEORIE (CONT.) 7. Air Cleaner 240 -volt Conversion Kit The AIRA electronic air cleaner comes ready for 115 -v operation. REQUIRED UE: This kit is required when running 240 -volt circuit to air cleaner. 8. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED UE: Fan coils in either downflow or horizontal applications. 9. Horizontal Applications - Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidity. UGGETED UE: All fan coils. 10. tandard Filter Rack Kit This kit mounts in fan coil filter rack area and modifies the existing filter rack to support standard 1 -in. filter sizes. UGGETED UE: Fan coils using standard filter sizes. Electric Heaters ACCEORY ELECTRIC HEATER HEATER PART NO. VOLT/ TAGE (KW INTERNAL CIRCUIT FAN COIL IZE HEATING CAP.** 240V PH OPERATING) PROTECTION UED 20V KFCEH0401N0 20/1 None 024 9,400 KFCEH0501N /1 5 None ,700 KFCEH0801N /1 8 None ,100 KFCEH0901N /1 10 None ,400 KFCEH / 5, 15 None ,100 KFCEH / 6, 12, 18 None 048, ,500 KFCEH2401C /1 5 Circuit Breaker ,700 KFCEH2501C /1 8 Circuit Breaker ,100 KFCEH2601C /1 10 Circuit Breaker ,400 KFCEH2901N /1, 9 None ,200 KFCEH001F /1 5, 15 Fuse ,100 KFCEH101C /1 5, 15 Circuit Breaker ,100 KFCEH201F /1 5, 20 Fuse ,800 KFCEH01C /1 5, 20 Circuit Breaker ,800 KFCEH401F /* 8, 16, 24 Fuse 048, ,00 KFCEH501F0 0 20/* 10, 20, 0 Fuse 048, ,100 * Field convertible to 1 phase. { Field convertible to phase. } ingle point wiring kit required for these heaters in Canada. ** Blower motor heat not included. Fan Coil Electrical Data (Units Without Electrical Heat) UNIT IZE VOLT (1-PHAE) FLA MCA Min Wire ize* AWG BRANCH CIRCUIT Max Wire Length (Ft/M) /64 225/ /8 150/ /27 100/ /27 100/0 15 * Use copper wire only to connect unit. If other than uncoated (nonplated), 75 C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANI/NFPA 70, U..A.). Length shown is as measured 1 way along wire path between unit and service panel for a maximum 2% voltage drop. FLA Full Load Amps; Rated in accordance with UL/U..A. tandard MCA Minimum Circuit Amps; Calculated in accordance with NEC/U..A. Article V 20V Fuse Amps A
11 Electric Heater (kw) / Elements ACCEORY ELECTRIC HEATER (CONT.) PHAE kw ELEMENT QTY
12 ACCEORY ELECTRIC HEATER ELECTRICAL DATA HEATER PART NO. KW P H A E INTERNAL CIRCUIT PROTEC- TION ingle Circuit HEATER AMP 208/20V Dual Circuit ingle Circuit Min Ampacity 208/20V** Dual Circuit 240v 208v L1,L2 L,L4 L1,L2 L,L4 Min Wire ize (AWG) 208/20V ingle Circuit Dual Circuit L1,L L,L 2 4 BRANCH CIRCUIT ingle Circuit Min Gnd Wire ize 208/20V Dual Circuit L1,L L,L 2 4 Max Fuse/Ckt Bkr Amps 208/20V ingle Circuit Dual Circuit ingle Circuit Max Wire Length 208/20V (Ft) Dual Circuit L1,L2 L,L4 L1,L2 L,L4 KFCEH0401N None 10.9/ /17. 12/12 12/12 20/20 67/68 KFCEH0501N None 18.1/ / /10 10/10 0/0 66/66 KFCEH0501N None 18.1/ /.5 8/8 10/10 5/5 85/88 KFCEH2401C Ckt Bkr 18.1/ / /10 10/10 0/0 66/66 KFCEH2401C Ckt Bkr 18.1/ /.5 8/8 10/10 5/5 85/88 KFCEH0801N None 28.9/ /48.5 8/8 10/10 45/50 59/60 KFCEH2501C Ckt Bkr 28.9/ /48.5 8/8 10/10 45/50 59/60 KFCEH2901N09* None 2.8/ /5.5 8/6 10/10 50/60 54/87 KFCEH2901N09 * None 18.8/ /4.5 8/8 10/10 5/5 8/85 KFCEH0901N None 6.2/ /58.5 6/6 10/10 60/60 78/80 KFCEH2601C Ckt Bkr 6.2/ /58.5 6/6 10/10 60/60 78/80 KFCEH001F15* Fuse 54.2/ / / / / /25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76 KFCEH101C15* Ckt Bkr 6.2/ / / /25.0 6/6 10/10 10/10 10/10 60/60 25/25 78/80 75/76 KFCEH None 1./ /51.8 8/6 10/10 50/60 56/90 KFCEH None 7.6/ /60.4 6/6 10/8 60/70 76/77 KFCEH201F20* Fuse 72./ / / / / /50.0 /2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59 KFCEH01C20* Ckt Bkr 6.2/ / / /50.0 6/6 8/8 10/10 10/10 60/60 50/50 78/80 59/59 KFCEH401F24 * KFCEH501F0 * Fuse 50.1/ /77.8 4/4 8/8 80/80 94/ Fuse 86.7/ / /1 6/6 125/ / Fuse 62.6/ /95.0 / 8/8 90/100 97/ Fuse 109.0/ / /00 6/6 150/ /150 FIELD MULTIPOINT WIRING OF 24 -AND 0 -KW INGLE PHAE HEATER PART NO. HEATER AMP MIN AMPACITY MIN WIRE IZE (AWG) KW MIN GND MAX FUE/CKT BKR AMP MAX WIRE LENGTH PHAE 208/20V 208/20V** 208/20V WIRE IZE 208/20V 208/20V (FT) 240V 208V L1,L2 L,L4 L5,L6 L1,L2 L,L4 L5,L6 L1,L2 L,L4 L5,L6 208/20V L1,L2 L,L4 L5,L6 L1,L2 L,L4 L5,L6 KFCEH401F24 * / / / / / /40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 7/7 7/7 KFCEH501F0 * / / / / / /50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59 { Field convertible to 1 phase, single or multiple supply circuit. } Field convertible to phase. ** Includes blower motor amps of largest fan coil used with heater. {{ Copper wire must be used. If other than uncoated (non---plated), 75_C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANI/NFPA 70). }} Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. NOTE: 1. For fan coil sizes For fan coil sizes ingle circuit application of F15 and F20 heaters requires single--- point wiring kit accessory. 12
13 Fan Coil Electrical Data (Units Without Electrical Heat) UNIT IZE Lw (db) English I Octave Band Center Frequency (HZ) CFM EP L/ EP FX4CX Hz FX4CX Hz FX4CX Hz FX4CX Hz METHOD: Estimated Fan ound Power (in decibels 10E-12 watts) is calculated in accordance with procedure described in AHRAE 1987 HVAC ystems and Applications Handbook, Chapter 52, ound and Vibration Control, using the pecific ound Power Level approach. ACCURACY: This is a prediction method, based on an accepted method which has demonstrated satisfactory results in field applications. However, field test results may generate sound pressure values which differ from these predicted values, as the current state of the art in determining sound power varies in accuracy from 0.2 db in mid-range (250 to 4000 Hz bands) to to 4 db in 125 and 8000 Hz bands and up to 6 to 8 db in 6 Hz band. MINOR CHANGE: Use for estimating sound power at other conditions of airflow and external static pressure. CONVERION FACTOR A14209 METRIC TECH X = ENGLIH UNIT X = I UNIT Area cm 100 mm cm in mm m 1.0 m m ft m Length µm 1.0 µm µm 9.7 micro-in µm mm 1.0 mm mm in mm mm ft 04.8 mm m 1.0 m m.281 ft m m yd m Mass g 1.0 g g oz 28.5 g kg 1.0 kg kg lb kg tonne. Mg 1.0 tonne. Mg tonne. Mg U.. ton tonne. Mg (2000 lb) Power kcal/h 1.16 W kcal/h.968 Btu/h W HP metric kw lb ft HP metric HP (550 s ) kw Mcal/h 1.16 kw Mcal/h 0.07 Ton ref..517 kw Pressure mm w.g 4 C Pa mm w.g 4 C in H 2 O 9.2 F Pa mm Hg 0 C 0.1 kpa mm Hg 0 C in Hg 2 F.86 kpa kg f /cm kpa kg f /cm psi kpa mh 2 O.281 ft H 2 O kpa METRIC TECH X = Temperature ENGLIH UNIT X = I UNIT Interval C 1.0 k C 1.8 F C Velocity m/s 1.0 m/s m/s.281 ft/s m/s m/s ft/min m/s Volume mm 1.0 x 10 6 L mm 6.102x10 in L L 1.0 L L ft 28.2 L m 1.0 m m 1.08 yd m L U.. gal.785 L L 2.11 U.. pint L ml. cm 1.0 ml ml. cm U.. oz ml Volume/Time m /h L/s m /h ft /min L/s m /h 4.40 U.. gal/min L/s L/h 2.778x10 4 L/s L/h 4.0x10 U.. gal/min L/s (m /h)/ (1000 kcal/h) cfm/ton L/s kw METRIC TECH Temperature C CONVERION FACTOR ENGLIH UNIT CONVERION FACTOR C K C ( Cx1.8) + 2 F ( F 2) 1.8 C I UNIT APPLICATION Install these units in the conditioned space or in an unconditioned space. They are tested and approved for installation in unconditioned space per ARI tandards (27 C; 80 F db, 24 C; 75 F wb indoor temperature; 27 C; 80 F db outdoor temperature). Insulate supply and return air ductwork in unconditioned space. It is recommended that insulation with vapor barrier be used. ound For acoustical treatment of ductwork, see FX4C Installation, tart-up, and ervice Instructions A
14 MATCHED YTEM OUTDOOR UNIT HUMIDIFIER FAN COIL AIR FLOW ELECTRONIC AIR CLEANER A0206 Copyright 2014 Carrier Corp. 710 W. Morris t. Indianapolis, IN 4621 Edition Date: 02/14 U.. Export Classification: EAR99. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: FX4C---C02PD Replaces: FX4C --- C1PD 14
Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:
PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR:
More informationSTANDARD FEATURES S S S S S S S S S S S S S S S S S S S S S S S S
TANDARD FEATURE Multi -tap ECM (electronic commutating motor) motors - all sizes Integrated motor controls, with 90 -sec off TDR function, have replaced integrated circuit board Five available speed tags
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationProduct Data. FX4C, FC4D Comfort Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST
, Comfort Series Fan Coil Sizes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST The and the fan coils combine the proven technology of Carrier fan coil units with either Puron, the environmentally
More informationProduct Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES
FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system
More informationProduct Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits
More informationProduct Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest
Product Data FA4A FB4A Direct Expansion Fan Coil Sizes 08 thru 070 Air Handling Technology At Its Finest Carrier s FA4A, FB4A, and direct expansion multipoise fan coils are designed to cover a wide range
More informationProduct Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil
FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)
FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air
More informationCFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)
ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV
More informationCFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More information135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944)
ENVIRONMENTALLY SOUND REFRIGERANT Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for Environmentally Sound R 410A systems Bolt
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air
More informationFEM4X, FSM4X, FSU4X. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT, FSU4X Product Specifications FAN COILS ALL MODELS Available for Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin
More informationFEM4P, FSM4P, FSU4P. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P, FSU4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering
More informationDimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT
ENVIRONMENTALLY SOUND REFRIGERANT B Series Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two--stage outdoor units Available for Environmentally Sound R--410A systems
More informationProduct Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES
LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air
More informationEBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES. Model Number
ENVIRONMENTALLY SOUND REFRIGERANT EBP Product Specifications EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES Multipoise design for maximum versatility 2 speed motor in 24 and 36 sizes 3 speed motor in
More informationFMU4X, FMC4X FMU4Z, FMC4Z
HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,
More informationCFM Range Tons x 21 1 / 8 x x 21 FVM*X4800A 48, FVM*X6000A 60, x 24 x x
FVM Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for R 22 or Environmentally Sound R 410A systems Bolt on, hard shut off TXV
More informationFEM, FSM, FSU. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS ALL MODELS 1½ thru 5 tons Available for R 22 or Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin coil Sweat
More informationËÕߪ Õ» ç åé. 50BY/BL Series. Single-Package Cooling Units 90, ,500 BTUH. World's No.1 Air Conditioning Expert
ËÕߪ Õ» ç åé BY/BL Series Single-Package Cooling Units 90,000-895,0 BTUH World's No.1 Air Conditioning Expert www.carrier.co.th BY/BL Series Features Commercial or Industrial Applications Single- or Multiple-Unit
More informationProduct Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )
13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation
More informationDIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS
Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without
More informationFEM, FSM, FSU. Product Specifications FAN COILS
FEM, FSM, FSU Product Specifications FAN COILS ALL MODELS 1½ thru 5 tons Available for R 22 or Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin coil
More informationFORM NO. HSC-543 AIR HANDLERS
FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationOperating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16
SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT
More informationAIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS
FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed
More informationN4A4 C. Product Specifications
COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationRheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor
Air Handlers Rheem Air Handlers RHLP- Standard Efficiency X-13 (ECM) Motor RHLP features an X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 1 1 /2 ton [.3 kw] through
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationRuud High Efficiency Air Handler
Air Handlers Ruud High Efficiency Air Handler RHLL- Series X-1 (ECM) Efficiencies up to 16 SEER RHLL feature an X-1 (ECM) motor which provides enhanced SEER performance with most Ruud outdoor units. Versatile
More informationTons BTU/h S.E.E.R* E.E.R** HSPF
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum
More informationARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit
More informationProduct Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz
18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationAIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features
FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler /RHT- Series Constant Torque (ECM) Efficiencies up to 16 SEER /RHT feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most
More informationTSA6. Product Specifications. SmartComfort TXC 5600
ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230
More information12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT
Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS
COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed
More informationAIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.
FORM NO. H22-523 REV. 4 Supersedes Form No. H22-523 Rev. 3 AIR HANDLERS AIR HANDLERS UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant Features earth friendly
More informationProduct Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons
SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 13 SEER Features/Benefits One-piece
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationA I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S
P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric
More informationELECTRIC HEAT AIR HANDLERS
ELECTRIC HEAT AIR HANDLERS 208/230V 1 1 /2 to 5 TONS High efficiency series for R-22 Certain models feature GE s new X-13 motor for enhanced SEER performance with most outdoor condensing units Multi-position
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationModular Variable Speed Air Handlers
Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A
More informationCAC SERIES 12-1/2 Thru 20 Ton
CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationAIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal
More information6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH
CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationProduct Data. 40RUA / 40RUS 6to30TonDirectExpansionwithPuron R Refrigerant 7.5to30TonChilledWater Packaged Air---Handling Units 60 Hz
/ 6toTonDirectExpansionwithPuron R Refrigerant 7.5toTonChilledWater Packaged Air---Handling Units 60 Hz Product Data 07 --- 12 --- C09035 C09036 Carrier s versatile packaged air-handling units satisfy
More informationDIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi--position design for horizontal or vertical installation without
More informationR4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors
More informationPACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE
COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationProduct Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)
SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece
More informationS3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant
TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from
More informationHMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS HMG*T Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG*T series of air handlers, when combined with our heat pump or air conditioner, offer
More informationB6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS B6BMMX Series Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The B6BMMX series of air handlers, when combined with our heat pump or air conditioner,
More informationHMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS HMG Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG Series of air handlers, when combined with our heat pump or air conditioner,
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationUARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60
TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationDIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
FAS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without
More informationPACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification
More informationDIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without
More informationGPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER
Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit
More informationBCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY
PRODUCT SPECIFICATIONS APPLICATION 1 1/2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (12/2018) INSTALLATION 1 piece design Smaller profile for
More informationCPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners
CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor
More informationAIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationProduct Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES
Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a
More informationPrecision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz
Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0
More informationProduct Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons
Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built
More informationProduct Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:
PH13PA 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory
More informationMERIT Series R-410A - Upflow / Horizontal - Variable Speed
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFN- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Ruud Indoor Coils are designed for use
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More information