Tons BTU/h S.E.E.R* E.E.R** HSPF
|
|
- Jason Wells
- 5 years ago
- Views:
Transcription
1 SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/ and REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin condenser and evaporator coils Scroll compressors standard on all models Short--cycling protection for the compressor is built into the defrost control board EASY TO INSTALL AND SERVICE Installs easily on a rooftop or at ground level Easy single--panel accessibility for maintenance and installation Easily converts to down discharge applications Combination electric heating and cooling BUILT TO LAST Wire Grille Direct drive high efficiency X--13 blower motor on all models Heavy--duty pre--painted steel cabinet Vertical condenser fan discharge Rust--proof base with integral sloping drain High and low pressure switches provide added reliability for the compressor WARRANTY 5--year compressor limited warranty 1--year parts limited warranty UNIT PERFORMANCE DATA COOLING Unit Dimensions Model Nominal Net HEATING* HeightxWidthxDepth Operating Number Tons BTU/h S.E.E.R* E.E.R** HSPF in (mm) Weight lb / kg PHD330000H00A 2--1/2 30, x48x33 (991x1226x831) 307 / 139 PHD336000(H,L)00A 3 35, x48x33 (1041x1226x831) 324 / 147 PHD342000(H,L)00A 3--1/2 40, x48x44 (1091x1226x1123) 382 / 173 PHD348000(H,L)00A 4 47, x48x44 (1091x1226x1123) 415 / 188 PHD360000(H,L)00A 5 57, x48x44 (1193x1226x1123) 434 / 197 * Rated in accordance with U.S. Government DOE (Department of Energy) test procedures and/or ARI Standards 210/240. ** A conditions--80 F (26.6 C) indoor db/67 F (19.4 C) indoor wb & 95 F(35 C) outdoor db. H = 208/ , L = (Voltage--Ph--Hz) Jan. 2009
2 UNIT SPECIFICATIONS MODEL NUMBER Electrical Data Circuit Breaker Volt - Ph - Hz or Fuse Minimum Circuit Ampacity Face Area (ft. 2) Condenser Coil Fan Motor Fan Fins Per Inch / Rows Tube Diameter (inch) Horse Power Full Load Amps Diameter (inches) RPM (Max.) CFM (Design) PHD330000H00A 208/ amps / 2 3/8 1/ PHD336000H00A 208/ amps / 2 3/8 1/ PHD336000L00A amps / 2 3/8 1/ PHD342000H00A 208/ amps / 2 3/8 1/ PHD342000L00A amps / 2 3/8 1/ PHD348000H00A 208/ amps / 2 3/8 1/ PHD348000L00A amps / 2 3/8 1/ PHD360000H00A 208/ amps / 2 3/8 1/ PHD360000L00A amps / 2 3/8 1/ MODEL NUMBER Face Area (ft. 2 ) Evaporator Coil Motor Blower Fins Per Inch / Rows Tube Diam. (inch) HP Full Load Amps Size (inches) RPM (Max) CFM (Rated) Scroll Compressor Rated Load Amps Locked Rotor Amps Factory Refrigerant Charge R -410A (lbs / kg) PHD330000H00A / 3 3/8 1/ x / PHD336000H00A / 4 3/8 3/ x / PHD336000L00A / 4 3/8 3/ x / PHD342000H00A / 3 3/8 3/ x / PHD342000L00A / 3 3/8 3/ x / PHD348000H00A / 3 3/ x / PHD348000L00A / 3 3/ x / PHD360000H00A / 4 3/ x / PHD360000L00A / 4 3/ x / PRESSURE SWITCHES Switch Type Cut -out PSIG Reset (automatic) PSIG High 650 +/ /-- 15 Loss of Charge (Low) 20 +/ /-- 10 UNIT PERFORMANCE DATA - HEATING HEATING Model Number High Heat F (8.3 C) High Heat F (8.3 C) Low Heat F (-8.3 C) Low Heat F (-8.3 C) PHD330000H 30, , PHD336000(H,L) 35, , PHD342000(H,L) 40, , PHD348000(H,L) 47, , PHD360000(H,L) 56, , Sound Ratings dba 2
3 UNIT PERFORMANCE DATA (Cont) Economizer 1 -in. Filter Pressure Drop (in. wc) UNIT PHD3 PRESSURE DROP Multiplicaton Factors HEATER kw RATING VOLTAGE DISTRIBUTION MULTIPLICATION FACTOR Electric Heat Pressure Drop Table, Small Cabinet - PHD kw kw kw kw kw Electric Heat Pressure Drop Table, Large Cabinet - PHD kw kw kw kw kw PHD3 Wet Coil Pressure Drop Standard CFM (S.C.F.M) Unit Size Filter Pressure Drop Table (In. W.C.) FILTER SIZE in. (mm) 20X20X1 (508X508X25) 20X24X1 (508X610x25) 24X30X1 (610X762x25) 24X36X1 (610X914X25) CFM
4 UNIT AIRFLOW, Horizontal and Downflow Discharge, Dry Coil Unit Motor Wire External Static Pressure (IN. W.C.) Speed Color Low Blue CFM Med--Low Pink CFM PHD330 Medium Red CFM Med--High 1 Orange CFM High 1 Black CFM Low Blue CFM Med--Low 1 Pink CFM PHD336 Medium Red CFM Med--High Orange CFM High Black CFM Low Blue CFM Med--Low Pink CFM PHD342 Medium Red CFM Med--High 1 Orange CFM High Black CFM Low Blue CFM Med--Low 1 Pink CFM PHD348 Medium Red CFM Med--High Orange CFM High Black CFM Low Blue CFM Med--Low Pink CFM PHD360 Medium 1 Red CFM Med--High Orange CFM High Black CFM * Air delivery values are without air filter and are for dry coil (See PHD3 Wet Coil Pressure Drop Table). 1 Factory---shipped cooling speed NOTE: Deduct field---supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting. MINIMUM AIRFLOW FOR RELIABLE ELECTRIC HEATER OPERATION (CFM) Model Size: Airflow: ELECTRIC HEATER USAGE CHART Electric Heater Model Number Nominal (kw) Fuses Used With Model Sizes ELECTRIC HEATERS (208 / PHASE 60 Hz) EHNA05H0N EHNA10H0N EHNA10H6F EHNA15H6F EHNA20H6F ELECTRIC HEATERS (460 3 PHASE 60 Hz) EHNA05L0N EHNA10L0N EHNA15L0N EHNA20L0N
5 ELECTRIC HEATER ELECTRICAL DATA MODEL SIZE NOMINAL V --- PH --- HZ VOLTAGE RANGE MIN MAX / / / / / ELECTRIC HEAT POWER SUPPLY NOMINAL kw Full Load Ampacity Minimum Circuit Maximum Over--- Ampacity Current Protection --- / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
6 PERFORMANCE DATA -STANDARD X -13 INDOOR MOTOR PHD330 Cooling Extended Performance Table CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) EVAPORATOR AIR Sens Sens Sens Sens Sens Sens EWB F( C) CFM / BF 57 (13.9) (16.7) * (17.2) (19.4) / (22.2) (13.9) (16.7) * (17.2) / (19.4) (22.2) (13.9) (16.7) * (17.2) / (19.4) (22.2) *At 75_F (23.9 _C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. PHD330 Heating Extended Performance Table 6 OUTDOOR COIL ENTERING AIR TEMPERATURES _F(_C) - 10 (- 23.3) 0 (- 17.8) 10 (- 12.2) 20 (- 6.7) 30 (- 1.1) 40 (4.4) 50 (10) 60 (15.6) INDOOR AIR Integ Integ Integ Integ Integ Integ Integ Integ EDB CFM (18.3) (21.1) (23.9)
7 PERFORMANCE DATA -STANDARD X -13 INDOOR MOTOR PHD336 Cooling Extended Performance Table EVAPORATOR AIR CFM / BF EWB F( C) CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Sens Sens Sens Sens Sens Sens 1050 / / / (13.9) (16.7) * (17.2) (19.4) (22.2) (13.9) (16.7) * (17.2) (19.4) (22.2) (13.9) (16.7) * (17.2) (19.4) (22.2) *At 75_F (23.9 _C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. PHD336 Heating Extended Performance Table INDOOR AIR EDB CFM OUTDOOR COIL ENTERING AIR TEMPERATURES _F(_C) - 10 (- 23.3) 0 (- 17.8) 10 (- 12.2) 20 (- 6.7) 30 (- 1.1) 40 (4.4) 50 (10) 60 (15.6) Integ Integ Integ Integ Integ Integ Integ Integ 65 (18.3) 70 (21.1) 75 (23.9)
8 PERFORMANCE DATA -STANDARD X -13 INDOOR MOTOR PHD342 Cooling Extended Performance Table CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) EVAPORATOR AIR Sens Sens Sens Sens Sens Sens EWB F( C) CFM / BF 57 (13.9) (16.7) * (17.2) (19.4) / (22.2) (13.9) (16.7) * (17.2) / (19.4) (22.2) (13.9) (16.7) * (17.2) / (19.4) (22.2) *At 75_F (23.9 _C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. PHD3042 Heating Extended Performance Table 8 OUTDOOR COIL ENTERING AIR TEMPERATURES _F(_C) - 10 (- 23.3) 0 (- 17.8) 10 (- 12.2) 20 (- 6.7) 30 (- 1.1) 40 (4.4) 50 (10) 60 (15.6) INDOOR AIR Integ Integ Integ Integ Integ Integ Integ Integ EDB CFM (18.3) (21.1) 75 (23.9)
9 PERFORMANCE DATA -STANDARD X -13 INDOOR MOTOR PHD348 Cooling Extended Performance Table EVAPORATOR AIR CFM / BF EWB F( C) CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Sens Sens Sens Sens Sens Sens 1400 / / / (13.9) (16.7) * (17.2) (19.4) (22.2) (13.9) (16.7) * (17.2) (19.4) (22.2) (13.9) (16.7) * (17.2) (19.4) (22.2) *At 75_F (23.9 _C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. PHD348 Heating Extended Performance Table INDOOR AIR EDB CFM OUTDOOR COIL ENTERING AIR TEMPERATURES _F(_C) - 10 (- 23.3) 0 (- 17.8) 10 (- 12.2) 20 (- 6.7) 30 (- 1.1) 40 (4.4) 50 (10) 60 (15.6) Integ Integ Integ Integ Integ Integ Integ Integ 65 (18.3) 70 (21.1) 75 (23.9)
10 PERFORMANCE DATA -STANDARD X -13 INDOOR MOTOR PHD360 Cooling Extended Performance Table CONDENSER ENTERING AIR TEMPERATURES _F(_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) EVAPORATOR AIR Sens Sens Sens Sens Sens Sens EWB F( C) CFM / BF 57 (13.9) (16.7) * (17.2) (19.4) / (22.2) (13.9) (16.7) * (17.2) / (19.4) (22.2) (13.9) (16.7) * (17.2) / (19.4) (22.2) *At 75_F (23.9 _C) entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. PHD360 Heating Extended Performance Table 10 OUTDOOR COIL ENTERING AIR TEMPERATURES _F(_C) - 10 (- 23.3) 0 (- 17.8) 10 (- 12.2) 20 (- 6.7) 30 (- 1.1) 40 (4.4) 50 (10) 60 (15.6) INDOOR AIR Integ Integ Integ Integ Integ Integ Integ Integ EDB CFM (18.3) (21.1) 75 (23.9)
11 LEGEND BF Bypass Factor edb Entering Dry---Bulb Ewb Entering Wet---Bulb kw Unit Power Input SHC Sensible Heat (1000 Btuh) TC (1000 Btuh) (net) rh Relative Humidity COOLING NOTES: 1. Ratings are net; they account for the effects of the evaporator---fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: t ldb = t edb --- Sensible capacity (Btuh) 1.10 x cfm t lwb = Wet---bulb temperature corresponding to enthalpy h lwb = h ewb --- total capacity (Btuh) air leaving evaporator coil ( h lwb) 4.5 x cfm Where: h ewb = Enthalpy of air entering evaporator coil 4. The SHC is based on 80_F (26.7 _C) edb temperature of air entering evaporator coil. Below 80_F (26.7_C) edb, subtract (corr factor x cfm) from SHC. Above 80_F (26.7_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb + 80). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 11
12 ACCESSORIES ROOF CURBS Screw (NO TE A) HVAC unit base Gasketing inner flange* Screw (NOTE A) HVAC unit base Gask eting inner flange* *Gasketing outer flange *Gasketing outer flange Flashing field supplied Wood nailer* Roofcurb* Flashing field supplied Wood nailer* Roofcurb* Roofing material field supplied Insulation (field supplied) Roofing material field supplied Insulation (field supplied) Cant strip field supplied Duct wo rk field supplied Cant strip field supplied Duct wo rk field supplied Roof Roof *Provided with roofcurb *Provided with roofcurb Roof Curb for Small Cabinet Note A: When unit mounting scre w is used, retainer bracke t must also be used. Roof Curb for Large Cabinet Note A: When unit mounting scre w is used, retainer bracket must also be used. G F B Typ. Supply opening (B x C) D C Typ. E G F R/A S/A A E D Gasket around duct Insulated deck pan Long Support Short Support Insulated deck pan Gasket around outer edge UNIT SIZE 30, 36 42, 48, 60 Return opening (B X C) MODEL NUMBER A IN. [MM] B IN. [MM] NPRFCURB006A00 8 [203] 11 [279] NPRFCURB007A00 14 [356] 11 [279] NPRFCURB008A00 8 [203] 16--3/16 [411] NPRFCURB009A00 14 [356] 16--3/16 [411] C IN. [MM] 16--1/2 [419] 16--1/2 [419] 17--3/8 [441] 17--3/8 [441] 12 D IN. [MM] E IN. [MM] F IN. [MM] G IN. [MM] 28--3/4 [730] 30--3/8 [771] 44--5/16 [1126] /16 [1167] 28--3/4 [730] 30--3/8 [771] 44--5/16 [1126] /16 [1167] 40--1/4 [1022] /16 [1065] 44--7/16 [1129] 46--1/16 [1169] 40--1/4 [1022] /16 [1065] 44--7/16 [1129] 46--1/16 [1169] Notes: 1. Seal strip must be applied as required to unit being installed. 2. Roof curb is made of 16 gauge steel. 3. Attach ductwork to curb (flanges of duct rest on curb). 4. Insulated panels: 1---in. thick fiberglass 1 lb. density. 5. When unit mounting screw is used (see Note A), a retainerbracketmustbeusedaswell.thisbracketmustalsobeusedwhenrequiredbycode for hurricane or seismic conditions. This bracket is available through Micrometl.
13 ECONOMIZERS (ALL FULLY MODULATING) ACCESSORIES (continued) Part Number Application Control Use With Model Size NPECOMZR003A00 30 NPECOMZR004A00 Horizontal, convertible to Downflow Dry Bulb (Enthalpy Control optional) 36, 42 NPECOMZR006A00 48, 60 All Economizers include Filter Racks but do not include filters. MANUAL FRESH AIR DAMPERS (use in DOWNFLOW application only) * Model Number Control Use With Model Size NPMANDPR004A00 30 NPMANDPR005A00 Manual 36, 42 NPMANDPR006A00 48, 60 * Unit must have internal filters to protect evaporator coil when Fresh Air Damper is installed. All Manual Fresh Air Dampers shipped with Filter Racks but without Filters. FILTER RACK and FILTER (shipped with 1 filters) Model Number Application Filter Size Use With Model Size 12 x 20 x 1 (quan. 2) or NPFILTRK004A00 30 Horizontal or 12 x 20 x 2 (quan. 1) PLUS 10 x 20 x 2 (quan.1) NPFILTRK005A00 Downflow 12 x 24 x 1 or 2 (3 required) 36, 42 NPFILTRK006A00 12 x 24 x 1 or 2 (3 required) 48, 60 CONCENTRIC DIFFUSER - Fits 2 x 4 Drop Ceiling Grid Model Number Description Use With Model Size AXB030CSA STEP DOWN -- Adapts round duct (18 dia.) to ceiling diffuser ALL AXB030CFA FLUSH MOUNT -- Adapts round duct (18 dia.) to ceiling diffuser ALL SQUARE to ROUND TRANSITION (Set of 2) - Use With Curb Model Number Round Size Square Size Use With Model Size NPDUCFLG002A x 16 ALL LIFTING / RIGGING KIT Model Number Description Use With Model Size NPLIFTBK003A10 Lifting / Rigging Kit (Set of 10) ALL 13
14 UNIT DIMENSIONS, model sizes 30, 36 Model Size UNIT HEIGHT inches [mm] CENTER OF GRAVITY inches [mm] A X Y Z [991] 20 [508] 19 [489] 18.0 [447] [1042] 20 [508] 14 [356] 13 [330] 14
15 UNIT DIMENSIONS, model sizes 42, 48, 60 UNIT HEIGHT inches [mm] CENTER OF GRAVITY inches [mm] Model Size A X Y Z [1092] 21 [533] 21. [533] 17 [422] [1092] 21 [533] 21 [533] 17 [422] [1193] 21 [533] 20 [508] 18 [447] 15
16 GUIDE SPECIFICATIONS CABINET Unit cabinet shall be constructed of phosphated, zinc--coated, pre--painted steel capable of with--standing 500 hours in salt spray. Normal service shall be through a single removable cabinet panel. The unit shall be constructed on a rust proof unit base that has an externally trapped, integrated sloped drain. Evaporator fan compartment top surface shall be insulated with a minimum 1/2--in. thick, flexible fiberglass insulation, coated on the air side and retained by adhesive and mechanical means. The evaporator wall sections will be insulated with a minimum semi--rigid foil--faced board capable of being wiped clean. Aluminum foil--faced fiberglass insulation shall be used in the entire indoor air cavity section. COOLING SECTION The unit is factory charged and operationally ready upon delivery. The unit refrigerant circuit has a high efficiency scrollcompressorwithinternaloverload protection, and copper tube / aluminum fin evaporator and condenser coils. The unit is designed for cooling operation to 40 o F and will be capable of being wired for field installed economizer type accessories. CORNER WEIGHTS and RIGGING DETAILS 1 2 COILS The evaporator and condenser coils are fabricated with aluminum fins mechanically bonded to copper tubing. Both coils are pressure tested prior to assembly into the unit and electronically leak tested after assembly into the unit. CONDENSER FAN The unit has a single direct-drive propeller-fan / motor assembly. The assembly is mounted directly to a vertical-discharge grille that is easily removed for service. Motors are 825 to 1100 RPM with sleeve or ball bearings and internal overload protection. EVAPORATOR BLOWER All units have a direct-drive X--13 evaporator blower motor as a standard. The direct-drive evaporator blower motor has sleeve bearings and internal overload protection. DETAIL A Model Size Operating Weight Corner Weight 1 Corner Weight 2 Corner Weight 3 Corner Weight CORNER WEIGHTS (SMALL CABINET) CORNER WEIGHTS (LARGE CABINET) lb kg lb kg Model Size lb kg lb kg lb kg Operating Weight Corner Weight Corner Weight Corner Weight Corner Weight
17 MODEL NOMENCLATURE MODEL SERIES P H D H 00 A 1 P = Package H = Heat Pump D = R-410A 3=13 SEER 30 = 30,000 BTUH = 2.5 Tons 36 = 36,000 BTUH = 3 Tons 42 = 42,000 BTUH = 3.5 Tons 48 = 48,000 BTUH = 4 Tons NOMINAL 60 = 60,000 BTUH = 5 Tons COOLING BTUH 000 = N/A NOMINAL HEATING BTUH H = 208/ L = VOLTAGE 00 = Standard FACTORY INSTALLED OPTIONS Sales Model Digit Engineering Digit 17
S/T Ratio. Input BTU/h
SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant
More informationProduct Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons
SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 13 SEER Features/Benefits One-piece
More information14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase
COMMERCIAL SOUND REFRIGERANT ENVIRONMENTALLY PAD4 Product Specifications 14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/230 1 60 Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A
More informationProduct Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)
SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece
More informationOperating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16
SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT
More informationProduct Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )
13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation
More informationPHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only
More information13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh
PGF3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency Copeland scroll compressor, 4 & 5 ton have two--stage
More information14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON
14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech
More informationPHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP 400v- 3-50 Hz FOR EXPORT USE Combination heating and cooling, self-contained for year-round comfort. Systems install on rooftop
More informationPHR5. Product Specifications
PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R
More informationCOMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt)
PAH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency
More informationCFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)
ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV
More informationQ6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged
More informationPGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No
PGMD Series 10 SEER PACKAGE COOLING 1-1/2THRU5TONSINGLEPHASE CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained
More informationRGMA Series Package Gas Electric SPECIFICATIONS
RGMA Series Package Gas Electric SPECIFICATIONS CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC COMMERCIAL GAS/ELECTRIC UNIT FEATURES EFFICIENCY 7-1/2 thru 20 ton Cooling, 200,000 thru 270,000 BTUH Heating SINGLE
More information14 SEER R -410A PACKAGE DUAL FUEL HEAT PUMP 2 to 5 TONS Two -Stage, Gas Heating / Electric Heating and Cooling Unit
SOUND REFRIGERANT ENVIRONMENTALLY As an Energy Star Partner, International ComfortProducts hasdetermined thatthis product meets the ENERGY STAR guidelines for energy efficiency. PDX4 Product Specifications
More informationCFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationCONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single
More informationPGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT
PGAA SERIES 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained for year-round comfort. Systems
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More information50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT
50JZ (50Hz.)-C1SB 50JZ 7 to 14 kw (024-048) STANDARD EFFICIENCY SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB
More informationQ6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged
More informationSizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions
PHH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE HEAT PUMP UNITS R 22, SINGLE PACKAGE ROOFTOP, 3 15 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency heat
More informationProduct Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits
More informationCOMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase)
PAE Product Specifications COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency
More informationAshrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number *
COMMERCIAL PAE Product Specifications Ashrae 90. EFFICIENCY PACKAGE A/C UNIT - 80 to 232 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual,
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationProduct Data. Fig. 1 - Unit 48VG -A and 48VG -B
VG---A and VG---B Performancet 16 SEER 2---Stage Packaged Air Conditioner and Gas Furnace System with PuronR (R---0A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig.
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationPRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES
PRODUCT SPECIFICATIONS 4 SEER HEAT PUMP PACKAGED UNIT FORM NO. -00 (03/207) REFRIGERANT SYSTEM Environmentally friendly R40A refrigerant Copper tubing with enhanced fin coils Internal service gauge ports
More informationQ6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY
TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationQ6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units
TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that
More informationSINGLE PACKAGE HEAT PUMPS
SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)
FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-
More informationProduct Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES
FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system
More informationFMU4X, FMC4X FMU4Z, FMC4Z
HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,
More informationGQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY
TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can
More informationProduct Data. Features/Benefits. 50TFQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons
Product Data 50TFQ004-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 3 to 10 Nominal Tons Single-package standard efficiency rooftop heat pumps with: State-of-the-art defrost system Dependable
More informationProduct Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES
LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air
More informationP6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units
TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility
More informationCOMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP TONS (3 PHASE)
PGS Product Specifications COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP -2 TONS ( PHASE) REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll
More informationRPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.
RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More informationCAC SERIES 12-1/2 Thru 20 Ton
CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer
More informationP6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can
More informationQ6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY
TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can
More informationQ4SE Series Single Packaged Heat Pump, Single Phase
TM TECHNICAL SPECIFICATIONS Q4SE Series Single Packaged Heat Pump, Single Phase Q4SE-14 SEER 2-5 Ton Units Cooling: 23,600 to 56,500 Btuh Heating: 22,200 to 55,500 Btuh The Q4SE Series single packaged
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More informationProduct Data. Features/Benefits. 50TJQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons
Product Data 50TJQ004-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 3 to 10 Nominal Tons Single-package standard efficiency rooftop heat pumps with: State-of-the-art defrost system Dependable
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH2SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE
More informationQ6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically
More informationPCB COMMERCIAL SERIES
PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner
More informationP6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS P6SD Series The P6SD Series packaged units are high efficiency self contained cooling units that can be installed on a roof or on a slab. The convertible unit design makes installations
More informationCPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A
CPC Series 15- & 20-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Air Conditioner with R-410A
More informationProduct Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil
FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationPRPAC14 PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER INSTALLATION WARRANTY
PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service
More informationPRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER
PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service gauge
More information13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.
13 SEER Light Commercial 3 Phase Packaged Heat Pump RHP13 Features and Benefits Form No. AC-RHP13-100 (05/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced
More informationP8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Three Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationPRAC14 PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT FORM NO. -100 (01/2017) REFRIGERANT SYSTEM Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils Internal service
More informationRCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.
RCE13 Product Specifications 13 SEER Electric / Electric Residential Packaged Unit Form No. RCE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically
More informationGP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units
TECHNICAL SPECIFICATIONS GP4SN Series Single Packaged Electric Cooling Units P4SN 10.3 EER Commercial System 7½ and 10 Ton Units These 7½ and 10 ton units are designed specifically for retrofit applications
More informationR6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units
TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained heating and cooling units
More informationP6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units
TM TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units
More informationP8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH1SE Series M1200 Product Line Single Packaged Heat Pump 14 SEER - 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE - 12 YEAR
More informationProduct Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons
Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built
More informationDTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER
DTC Series Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model P6SD Series M120 Product Line Single Packaged Air Conditioning, 13 SEER - R-410A, 3, 4 and 5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability
More informationCPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h
CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4
More informationR6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY
TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained cooling units
More informationProduct Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:
PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR:
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationGPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H
GPH13H PACKAGED HEAT PUMP 13 SEER 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H The Goodman GPH13H 13 SEER Packaged Heat Pump provides energy-efficient cooling
More informationR6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY
TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility
More information6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH
CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration
More informationCPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A
CPG Series 3- to 6-Ton Self-Contained Submittal Data Form Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Gas/Electric with R-410A Standard Features
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationDIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS
Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without
More informationQ5RD Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged
More informationGQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY
TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged
More informationDCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE
Submittal Data Form Job Name DCG Series 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Cooling Capacity: 88,000 144,000 BTU/h Heating Capacity (Output): 168,000 BTU/h Purchaser Order No.
More informationProduct Data. Features/Benefits
Product Data 50TFQ008-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 50 Hz Nominal Capacities: 26.4 to 35.2 kw (7 1 / 2 to 10 Nominal Tons) Single-package standard efficiency rooftop heat
More informationZHA/ZHB SERIES WARNING
Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More informationGR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS
TECHNICAL SPECIFICATIONS GR4GN Series Single Packaged Gas/Electric Units GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units The GR4GN is designed specifically for retrofit applications and compatibility
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationQ4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS
TM TECHNICAL SPECIFICATIONS Q4SD Series Single Packaged Heat Pump, Single Phase Q4SD-13 SEER 3-5 Ton Units Cooling: 30,000 to 58,000 Btuh Heating: 29,000 to 59,000 Btuh The Q4 Series single packaged heat
More informationPGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT. PGF = Standard Models PGC = California Models with NOX baffles
PGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF = Standard Models PGC = California Models with NOX baffles C 1-1/2 THRU 5 TON, SINGLE PHASE Efficiency: PGF / PGC - 10 SEER. Combination
More informationZ-Series Rooftop Units 60 HZ
PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS ZH Z-Series Rooftop Units 60 HZ Bulletin No. ZHA-036-060 (0/03) MODEL NUMBER IDENTIFICATION ASHRAE 90. COMPLIANT 3 to 5 Tons Net Cooling Capacity 36,00 to 58,000
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More information