Product Data. FX4C, FC4D Comfort Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Size: px
Start display at page:

Download "Product Data. FX4C, FC4D Comfort Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST"

Transcription

1 , Comfort Series Fan Coil Sizes 018 thru 060 Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST The and the fan coils combine the proven technology of Carrier fan coil units with either Puron, the environmentally sound refrigerant, or R -22 refrigerant.. Both fan coils are loaded with popular features. Factory installed, refrigerant specific, thermostatic expansion valves (TXV) are standard with all these fan coil designs. These designs feature contoured condensate pans with rugged, brass drain connections. These pans ensure that little water is left in the unit after the end of cooling duty cycle. The lack of standing condensate and corrosion free pans improves IAQ and product life, features homeowners appreciate. Standard features for both include grooved copper tubing, louvered aluminum fins. The large face areas of the refrigerant coils provide superior efficiency, for high SEER and HSPF performance. Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners. Also units come with solid state fan controls, 1 -inch thick insulation, with R value of 4.2, super -quiet multi -speed motors, and fully wettable coils. Units can accommodate factory and/or field installed heaters from 3 to 30 kw. The fan coil is the Puron design loaded with popular features. It comes in a pre -painted (Taupe Metallic) galvanized steel casing and is shipped with a cleanable, permanent framed filter and a factory supplied power plug. The units have full range of X13, high efficiency blower motors, available in sizes 018 through 060. The fan coil comes with all those same features as the, but for use with R -22 refrigerant. It also should be noted that the unique cabinet design of these fan coils meet new stringent regulations for cabinet air leakage - a requirement of 2% cabinet leakage rate when tested at 1.0 inches of static pressure.

2 STANDARD FEATURES S Super high efficiency X13 motors - all sizes S Simple control board with blower-off delay, and internal thermostat wire junction box S Large, grooved tube, louvered fin coils S Dedicated refrigerant circuits S Efficient, quiet, time tested blower housings and diffusers S Sturdy, drainable condensate pans S Cabinet construction features innovations designed to prevent cabinet sweating S Brass drain connections S Tested for condensate disposal in much tougher conditions than Air Conditioning and Refrigeration Institute requirements S Super thick R -4.2 insulation with vapor barrier S Pro -painted galvanized steel cabinet (Taupe Metallic) S Cabinet design meets stringent regulations for 2% cabinet leakage rate when tested at 1.0 inches static pressure S Installation -flexible, multipoise units S Horizontal hanging provisions on cabinetry S No tools required to service filter S Factory supplied, cleanable and reusable filter S Newly improved filter rack area -filter door insulation added for improved air seal S 3 - through 30 -kw accessory heaters - Field Installed S Factory supplied power plug S Easy plug -in provisions for heater installation S Entry options for high and low voltage wiring hook -up S Simple, 5 -amp blade fuse (and a spare) to protect 40 VA transformer S Easy coil inspection (removable, snap -in plug on A -coil models) S Leak -preventing sweat connections S Puron, Environmentally Sound Refrigerant S Factory installed Puron thermostatic expansion valves (TXV) S R -22 refrigerant S Factory installed R -22 thermostatic expansion valves (TXV) S Factory installed heater packages available ADDITIONAL FEATURES 2

3 NOMENCLATURE CHART CARRIER FAN COILS , 8, 9 10, 11, F X 4 C N F A A A A Variations Heating Size (kw) Product Series Type Position Major Series Electrical Cabinet/Insulation Nominal Capacity (Btu) no heat kw kw kw kw 018 = 18, = 24, = 30, = 36, = 42, = 48, = 60,000 B = Modular w/ in. super thick insulation 4 = Multipoise N = 208/230v--- 1ph---60hz F = Fan Coil X = Comfort, Puron C=Comfort, R F=Singlepiece cabinet with 1--- in. super thick insulation ISO 9001:2000 Y C ERTIFIED TO AR I A SC WITH O MPLYING N DITIONING A IRCO MANUFACTU RER UN ITAR REGISTERED E QUIPMEN T A RI STANDAR D 210 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI 3

4 036 Puron - 3/4" I.D.SWEAT 036 R-22-7/8" I.D.SWEAT /8"I.D.SWEAT LIQUID: 3/8" I.D. SWEAT CONDENSATE: 3/4" FPT UNIT SIZE FX, FC COIL TYPE DIMENSIONS A B C D E H J In. mm In. mm In. mm In. mm In. mm In. mm In. mm 018* Slope / / / / / * Slope / / / / / * Slope / / / / / * Slope / / / / / * A / / / / / * A / / / / / * A / / / / / ** Slope / / / / / / ** A / / / / / / ** A / / / / / / ** A / / / / / / * Single piece cabinet ** Modular cabinet Applicable to modular units only. A

5 UNIT SIZE FX, FC COIL TYPE DIMENSIONS (CONT.) F G In. mm In. mm 018* Slope / / * Slope / / * Slope / / * Slope / / * A / / * A / / * A / / ** A / / ** A / / ** A / / ** A / / * Single piece cabinet ** Modular cabinet Applicable to modular units only. A

6 ODS CATALOG ORDERING NO. FACTORY INSTALLED HEAT (KW) PHYSICAL DATA NOMINAL COOLING CAPACITY (BTUH) DIMENSIONS Height Width Depth SHIPPING WEIGHT NF , / / / NF , / / / NF , / / / NF , / / / NF , / / / NF , / / / NF , / / / NB , / / / NB , / / / NB , / / / NB , / / / th digit: B --- Modular Cabinet F --- Single piece cabinet ODS CATALOG ORDERING NO. FACTORY INSTALLED HEAT (KW) NOMINAL COOLING CAPACITY (BTUH) DIMENSIONS SHIPPING WEIGHT Height Width Depth NF NF NF , / / / NF NF NF NF , / / / NF NF NF NF , / / / NF NF NF NF NF , / / / NF NF NF NF NF , / / / NF NF NF NF , / / / NF NF NF , / / / NB , / / / NB , / / / NB , / / / NB , / / / th digit: B --- Modular Cabinet F --- Single piece cabinet 6

7 SPECIFICATIONS MODEL COIL Refrigerant Metering Device TXV --- factory installed hard shut --- off, byflow --- type for heat pump application TXV SIZE 2ton 3ton 4ton Rows/Fins Per In. 3 / 14.5 Face Area (Sq Ft) Configuration Slope A FAN CFM (Nominal) Motor Type X X X X X X X Motor Hp 1/3 1/3 1/3 1/2 1/2 3/4 3/4 Filter /2 x / / /16 CABINET CONFIGURATION OPTIONS piece piece piece piece or piece or piece or piece or Modular Modular Modular Modular MODEL COIL Refrigerant Metering Device TXV --- factory installed hard shut --- off, byflow --- type for heat pump application TXV SIZE 3ton 5ton 6ton Rows/Fins Per In. 3 / 14.5 Face Area (Sq Ft) Configuration Slope A FAN CFM (Nominal) Motor Type X X X X X X X Motor Hp 1/3 1/3 1/3 1/2 1/2 3/4 3/4 FILTER /2 x / / /16 CABINET CONFIGURATION OPTIONS piece piece piece piece or piece or piece or piece or Modular Modular Modular Modular PERFORMANCE DATA AIRFLOW PERFORMANCE (CFM) TOTALEXTERNALSTATICPRESSURE Model & Size Blower Speed High , Medium Low High , Medium Low High , Medium Low High , Medium Low High , Medium Low High , Medium Low High , Medium Low Notes: 1. Airflow based upon dry coil at 230v with factory approved filter and electric heater (2 element heater sizes 18 through 36, 3 element heater sizes 42 through 60). 2. To avoid potential for condensate blowing out of drain pan prior to making dran trap: Return static pressure must be less than 0.40 in. wc. Horizontal applications of sizes must have supply static greater than 0.20 in. wc. 3. Shading - Airflow outside 450 cfm/ton. 4. Airflow above 400 cfm/ton on size could result in condensate blowing off coil or splashing out of drain pan. 7

8 Unit Size PERFORMANCE DATA (CONT.) GROSS COOLING CAPACITIES (mbh) INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR (deg F) AIR CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF

9 UNIT SIZE 060 UNIT SIZE PERFORMANCE DATA (CONT.) GROSS COOLING CAPACITIES (mbh) INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR (deg F) AIR CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF GROSS COOLING CAPACITIES (MBH) INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR (deg F) AIR CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF

10 UNIT SIZE PERFORMANCE DATA (CONT.) GROSS COOLING CAPACITIES (mbh) INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR (deg F) AIR CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF CFM - Cubic Ft. per Minute EWB - Entering Wet Bulb (_F) LWB - Leaving Wet Bulb (_F) TC - Gross Cooling Capacity 1000 Btuh SHC - Gross Sensible Capacity 1000 Btuh BF - Bypass Factor MBH Btuh NOTES: 1. Contact manufacturer for cooling capacities at conditions other than SHC CORRECTION FACTOR shownintable. 2. Formulas: Leaving db = entering db -sensible heat cap x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (h lwb ) h lwb =h ewb -total capacity (Btuh) 4.5xCFM where h ewb = enthalpy of air entering coil. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 80_F db temperature of air entering coil. Below80_F db, subtract (Correction Factor x CFM) from SHC. Above 80_F db, add (Correction Factor x CFM) to SHC. 4. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. Interpolation is permissible. Correction Factor = 1.09 x (1 --- BF) x (db ) BYPASS FACTOR ENTERING AIR DRY-- BULB TEMPERATURE (_F) Under Over 85 Correction Factor Use formula shown below MINIMUM CFM AND MOTOR SPEED SELECTION FAN COIL SIZES HEATER KW, * * * *Indicates medium speed (blue). All other motor speeds at low tap. AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN. WC) AT INDICATED AIRFLOW (DRY -TO -WET COIL) FX, FC Size CFM

11 HEATER ELEMENTS ELECTRIC HEATER STATIC PRESSURE DROP (IN. WC) KW EXTERNAL STATIC HEATER PRESSURE ELEMENTS CORRECTION KW EXTERNAL STATIC PRESSURE CORRECTION , , , , , , 24, The airflow performance data was developed using fan coils with 10---kw electric heaters (2 elements) in the 018 through 036 size units and 15---kw heaters (3 elements) in the 042 through 070 size units. For fan coils with heaters of a different number of elements, the external available static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. ACCESSORY ELECTRIC HEATERS HEATER PART NO. 240V VOLTS/PH STAGES (KW OPERATING) INTERNAL CIRCUIT PROTECTION FAN COIL SIZE USED WITH HEATING 230V KFCEH0401N /1 3 None ,400 KFCEH0501N /1 5 None ,700 KFCEH0801N /1 8 None ,100 KFCEH0901N /1 10 None ,400 KFCEH3201F /1 5, 20 Fuse} ,800 KFCEH /3 5, 15 None ,100 KFCEH /3 6, 12, 18 None ,500 KFCEH3401F /3* 8, 16, 24 Fuse 048, ,300 KFCEH3501F /3* 10, 20, 30 Fuse 048, ,100 KFCEH2401C /1 5 Circuit Breaker ,700 KFCEH2501C /1 8 Circuit Breaker ,100 KFCEH2601C /1 10 Circuit Breaker ,400 KFCEH3301C /1 5, 20 Circuit Breaker ,800 KFCEH2901N /1{ 3, 9 None ,200 KFCEH3001F /1 5, 15 Fuse} ,100 KFCEH3101C /1 5, 15 Circuit Breaker ,100 * Field convertible to 1 phase. { Field convertible to 3 phase } Single point wiring kit required for these heaters in Canada. ** Blower Motor heat not included. ESTIMATED SOUND POWER LEVEL (dba) CONDITIONS OCTAVE BAND CENTER FREQUENCY* UNIT SIZE Ext Static FX, FC CFM Pressure * Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, Chapter 52, p

12 Model No. ELECTRICAL DATA FOR UNITS WITH FACTORY -INSTALLED HEATERS Mtr HP Mtr FLA Ph/ Hz Heat Pack Installed Heater Amps Min. Ampacity Max. Overcur. Protect. Heater Amps Min. Ampacity Max. Overcur. Protect. Heater Amps Min. Ampacy Max. Overcur. Protection L1/L2 L1/L2 L1/L2 L3/L4 L3/L4 L3/L4 NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 N/A N/A N/A N/A N/A N/A N/A NB / /60 N/A N/A N/A N/A N/A N/A N/A NB / /60 N/A N/A N/A N/A N/A N/A N/A NB / /60 N/A N/A N/A N/A N/A N/A N/A NB / /60 N/A N/A N/A N/A N/A N/A N/A Model No. Mtr HP Mtr FLA Ph/ Hz Heat Pack Installed Heater Amps Min. Ampacity Max. Overcur. Protect. Heater Amps Min. Ampacity Max. Overcur. Protect. Heater Amps Min. Ampacy Max. Overcur. Protection L1/L2 L1/L2 L1/L2 L3/L4 L3/L4 L3/L4 NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0501N / / /30 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0801N / / /45 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0901N / / /60 N/A N/A N/A N/A N/A N/A NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0501N / / /30 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0801N / / /45 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0901N / / /60 N/A N/A N/A N/A N/A N/A NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0501N / / /30 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0801N / / /45 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0901N / / /60 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH1501F / / / / / / / / /25 NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0501N / / /30 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0801N / / /45 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0901N / / /60 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH1501F / / / / / / / / /25 NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0801N / / /45 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0901N / / /60 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH1501F / / / / / / / / /25 NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0801N / / /45 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0901N / / /60 N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH1501F / / / / / / / / /25 NF / /60 N/A N/A N/A N/A N/A N/A N/A NF / /60 MKFCEH0901N / / /60 N/A N/A N/A N/A N/A N/A NB / /60 N/A N/A N/A N/A N/A N/A N/A NB / /60 N/A N/A N/A N/A N/A N/A N/A NB / /60 N/A N/A N/A N/A N/A N/A N/A NB / /60 N/A N/A N/A N/A N/A N/A N/A Unit Size, Volts (1 Phase) FAN COIL ELECTRICAL DATA (UNITS WITHOUT ELECTRICAL HEAT) FLA MIN CKT AMPS BRANCH CIRCUIT Min Wire Size* AWG Fuse/Ckt Bkr Amps 018, 024, / , / , / *Usecopperwireonly.Use75_C only in this application. When using non---metallic (NM) sheathed cable, wire size required should be based on that of 60_C conductors, instead of wire sizes shown in table above per NEC Article FLA --- Full Load Amps NOTE: If branch circuit wire length exceeds 100 ft, consult NEC to determine maximum wire length. Use 2% voltage drop. 12

13 ACCESSORY ELECTRIC HEATER ELECTRICAL DATA HEATER PART NO. KW P H A S E INTERNAL CIRCUIT PROTEC- TION HEATER AMPS 208/230V Min Ampacity 208/230V** Dual Circuit Min Wire Size (AWG) 208/230V BRANCH CIRCUIT Min Gnd Wire Size 208/230V Max Fuse/Ckt Bkr Amps 208/230V Max Wire Length 208/230V (Ft) Dual Circuit Single Dual Circuit Single Single Dual Circuit Single Dual Circuit Single Dual Circuit Single 240v 208v Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 KFCEH0401N None 10.9/ / /12 12/12 20/20 67/68 KFCEH0501N None 18.1/ / /10 10/10 30/30 66/66 KFCEH0501N None 18.1/ /33.5 8/8 10/10 35/35 85/88 KFCEH2401C Ckt Bkr 18.1/ / /10 10/10 30/30 66/66 KFCEH2401C Ckt Bkr 18.1/ /33.5 8/8 10/10 35/35 85/88 KFCEH0801N None 28.9/ /48.5 8/8 10/10 45/50 59/60 KFCEH2501C Ckt Bkr 28.9/ /48.5 8/8 10/10 45/50 59/60 KFCEH2901N09*** None 32.8/ /53.5 8/6 10/10 50/60 54/87 KFCEH2901N09 *** None 18.8/ /34.5 8/8 10/10 35/35 83/85 KFCEH0901N None 36.2/ /58.5 6/6 10/10 60/60 78/80 KFCEH2601C Ckt Bkr 36.2/ /58.5 6/6 10/10 60/60 78/80 KFCEH3001F15*** Fuse 54.2/ / / / / /25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76 KFCEH3101C15*** Ckt Bkr 36.2/ / / /25.0 6/6 10/10 10/10 10/10 60/60 25/25 78/80 75/76 KFCEH None 31.3/ /51.8 8/6 10/10 50/60 56/90 KFCEH None 37.6/ /60.4 6/6 10/8 60/70 76/77 KFCEH3201F20*** Fuse 72.3/ / / / / /50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59 KFCEH3301C20*** Ckt Bkr 36.2/ / / /50.0 6/6 8/8 10/10 10/10 60/60 50/50 78/80 59/59 KFCEH3401F24 *** KFCEH3501F30 *** Fuse 50.1/ /77.8 4/4 8/8 80/80 94/ Fuse 86.7/ / /1 6/6 125/ / Fuse 62.6/ /95.0 3/3 8/8 90/100 97/ Fuse 109.0/ / /00 6/6 150/ /150 FIELD MULTIPOINT WIRING OF 24 -AND 30 -KW SINGLE PHASE HEATER PART NO. HEATER AMPS MIN AMPACITY MIN WIRE SIZE (AWG) KW MIN GND MAX FUSE/CKT BKR AMPS MAX WIRE LENGTH PHASE 208/230V 208/230V** 208/230V WIRE SIZE 208/230V 208/230V (FT) 240V 208V L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 208/230V L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L5,L6 KFCEH3401F24 *** / / / / / /40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73 KFCEH3501F30 *** / / / / / /50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59 { Field convertible to 1 phase, single or multiple supply circuit. } Field convertible to 3 phase. ** Includes blower motor amps of largest fan coil used with heater. {{ Copper wire must be used. If other than uncoated (non---plated), 75_C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). }} Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. *** Heaters are Intelligent Heat capable when used with the FE, FK and FV fan coils and corporate 2---speed programmable thermostat (TSTATCCP2S01---B), Thermidistatt Control (TSTATCCPRH01---B), or Comfort Zone. NOTES: 1. For fan coil sizes For fan coil sizes and all FE, FK4D, FV4B sizes. 3. Single circuit application of F15 and F20 heaters requires single---point wiring kit accessory 13

14 FACTORY -INSTALLED FILTER STATIC PRESSURE DROP (IN. WC) UNIT SIZE CFM FX, FC FACTORY -INSTALLED HEATER OPTIONS* MODEL NF 5, 8, 10 5, 8, 10 5, 8, 10, 15 5, 8, 10, 15 8, 10, 15 8, 10, * For field---installed heater/fan coil combinations, see Electric Heaters on page 14. ELECTRIC HEATER INTERNAL PROTECTION HEATER KW PHASE FUSE CKT BKR* QTY/SIZE QTY/SIZE 5 1 1/ /60 9 1/ / /30 2/60 2/ /60 2/ /1 6/ /1 6/60 *All circuit breakers are 2 pole. 14

15 ACCESSORIES ITEM ACCESSORY PART NO.* FAN COIL SIZE USED WITH 1. Disconnect Kit KFADK0201DSC Cooling controls and heaters 3--- through kw KFACB0101CFB Downflow Base Kit KFACB0201CFB 024, 030 KFACB0301CFB 036, 042, 048 KFACB0401CFB Downflow Conversion Kit KFADC0201SLP Slope Coil Units 018, 024, 030, 036 KFADC0401ACL A--- Coil Units 042, 048, Single--- Point Wiring Kit KFASP0101SPK Only with and kw Fused Heaters KFAFK0112SML Filter Kit (12 Pack) KFAFK0212MED 024, 030 KFAFK0312LRG 036, 042, 048 KFAFK0412XXL Power Plug Kit (25 Pack) KFAPP0125PLG All 7. PVC Condensate Trap Kit (50 pack) KFAET0150ETK All 8. Air Cleaner volt Conversion Kit KEAVC All 9. Downflow/Horizontal Conversion Gasket Kit KFAHD0101SLP All 10. Horizontal Water Management Kit (25 pack) KFAHC0125AAA All * Factory authorized and listed, field installed. Accessory Kits Description Suggested and Required Use. 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: Units for 3 - through 10 -kw electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1 -in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap free seal with the floor. REQUIRED USE: This kit must be used whenever fan coils are used in Downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A -coils. REQUIRED USE: This kit must be used whenever fan coils are used in Downflow applications. 4. Single Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run 2 heavy -gage, highvoltage wires into the fan coil rather than 4 light-gage, high -voltage wires. SUGGESTED USE: Fan coils with 15 - and 20 -kw fused heaters only. 5. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and in turn the efficiency of the system. SUGGESTED USE: To replace filters in fan coils. REQUIRED USE: All units unless a filter grille is used. 6. Power Plug Kit The kit consists of 25 wire harness assemblies. Each plug provides the high -voltage power connection to the fan coil in the absence of electric heat. REQUIRED USE: Units installed without electric heat. 7. Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps. Each trap is pre-formed and ready for field installation. This deep trap helps the system make and hold proper condensate flow even during blower initiation. SUGGESTED USE: All fan coils. 8. Air Cleaner 240 -volt Conversion Kit The AIRA electronic air cleaner comes ready for 115 -v operation. REQUIRED USE: This kit is required when running 240 -volt circuit to air cleaner. 9. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a Downflow or Horizontal application. REQUIRED USE: Fan coils in either Downflow or Horizonatal applications. 10. Horizontal Applications - Water Management Kit This kit provides proper installation of fan coils under conditions of high static prossure and high relative humidty. SUGGESTED USE: All fan coils. Copyright 2005 Carrier Corp W. Morris St. Indianapolis, IN Printed in U.S.A. Edition Date: 12/05 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: ---2PD Replaces: -1PD 15

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR:

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

STANDARD FEATURES S S S S S S S S S S S S S S S S S S S S S S S S

STANDARD FEATURES S S S S S S S S S S S S S S S S S S S S S S S S TANDARD FEATURE Multi -tap ECM (electronic commutating motor) motors - all sizes Integrated motor controls, with 90 -sec off TDR function, have replaced integrated circuit board Five available speed tags

More information

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest Product Data FA4A FB4A Direct Expansion Fan Coil Sizes 08 thru 070 Air Handling Technology At Its Finest Carrier s FA4A, FB4A, and direct expansion multipoise fan coils are designed to cover a wide range

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

FMU4X, FMC4X FMU4Z, FMC4Z

FMU4X, FMC4X FMU4Z, FMC4Z HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,

More information

FEM4X, FSM4X, FSU4X. Product Specifications

FEM4X, FSM4X, FSU4X. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT, FSU4X Product Specifications FAN COILS ALL MODELS Available for Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin

More information

EBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES. Model Number

EBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES. Model Number ENVIRONMENTALLY SOUND REFRIGERANT EBP Product Specifications EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES Multipoise design for maximum versatility 2 speed motor in 24 and 36 sizes 3 speed motor in

More information

FEM4P, FSM4P, FSU4P. Product Specifications

FEM4P, FSM4P, FSU4P. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P, FSU4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering

More information

135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944)

135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944) ENVIRONMENTALLY SOUND REFRIGERANT Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for Environmentally Sound R 410A systems Bolt

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

Product Data. FX4C (50 Hz) Direct Expansion Fan Coil Sizes 024 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FX4C (50 Hz) Direct Expansion Fan Coil Sizes 024 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST FX4C (50 Hz) Direct Expansion Fan Coil izes 024 thru 060 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The FX4C fan coil is the latest in air handling technology. It s the one to choose for high efficiency

More information

Dimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT

Dimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT ENVIRONMENTALLY SOUND REFRIGERANT B Series Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two--stage outdoor units Available for Environmentally Sound R--410A systems

More information

CFM Range Tons x 21 1 / 8 x x 21 FVM*X4800A 48, FVM*X6000A 60, x 24 x x

CFM Range Tons x 21 1 / 8 x x 21 FVM*X4800A 48, FVM*X6000A 60, x 24 x x FVM Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for R 22 or Environmentally Sound R 410A systems Bolt on, hard shut off TXV

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

FEM, FSM, FSU. Product Specifications FAN COILS

FEM, FSM, FSU. Product Specifications FAN COILS FEM, FSM, FSU Product Specifications FAN COILS ALL MODELS 1½ thru 5 tons Available for R 22 or Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin coil

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.   DESCRIPTION FEATURE TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.     DESCRIPTION TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a

More information

N4A4 C. Product Specifications

N4A4 C. Product Specifications COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

FEM, FSM, FSU. Product Specifications

FEM, FSM, FSU. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS ALL MODELS 1½ thru 5 tons Available for R 22 or Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin coil Sweat

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

Product Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 13 SEER Features/Benefits One-piece

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information

CAC SERIES 12-1/2 Thru 20 Ton

CAC SERIES 12-1/2 Thru 20 Ton CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

FORM NO. HSC-543 AIR HANDLERS

FORM NO. HSC-543 AIR HANDLERS FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed

More information

Q5RD Series Single Packaged Heat Pump, Single Phase

Q5RD Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

Product Data. 40RUA / 40RUS 6to30TonDirectExpansionwithPuron R Refrigerant 7.5to30TonChilledWater Packaged Air---Handling Units 60 Hz

Product Data. 40RUA / 40RUS 6to30TonDirectExpansionwithPuron R Refrigerant 7.5to30TonChilledWater Packaged Air---Handling Units 60 Hz / 6toTonDirectExpansionwithPuron R Refrigerant 7.5toTonChilledWater Packaged Air---Handling Units 60 Hz Product Data 07 --- 12 --- C09035 C09036 Carrier s versatile packaged air-handling units satisfy

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification

More information

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

ELECTRIC HEAT AIR HANDLERS

ELECTRIC HEAT AIR HANDLERS ELECTRIC HEAT AIR HANDLERS 208/230V 1 1 /2 to 5 TONS High efficiency series for R-22 Certain models feature GE s new X-13 motor for enhanced SEER performance with most outdoor condensing units Multi-position

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency

More information

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient

More information

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GP5RD Series Single Packaged Air Conditioner, Single Phase GP5RD-13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 60,000 Btuh The GP5 Series single packaged air conditioners

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

Product Data. 40RUA/40RUS 6to30TonDirectExpansion 7.5to30TonChilledWater Packaged Air- Handling Units FEATURES/BENEFITS

Product Data. 40RUA/40RUS 6to30TonDirectExpansion 7.5to30TonChilledWater Packaged Air- Handling Units FEATURES/BENEFITS / 6toTonDirectExpansion 7.5toTonChilledWater Packaged Air- Handling Units Product Data 40RU07-40RU - C09035 C09036 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY PRODUCT SPECIFICATIONS APPLICATION 1 1/2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (12/2018) INSTALLATION 1 piece design Smaller profile for

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

TSA6. Product Specifications. SmartComfort TXC 5600

TSA6. Product Specifications. SmartComfort TXC 5600 ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230

More information

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60 TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi--position design for horizontal or vertical installation without

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS 07---25 SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz Product Data 07-12 16-25 C10887 Carrier s versatile packaged heat pump air-handling units satisfy design requirements

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY PRODUCT SPECIFICATIONS APPLICATION 2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (11/2018) INSTALLATION One piece design Smaller profile for closet

More information

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology

More information

Ruud High Efficiency Air Handler

Ruud High Efficiency Air Handler Air Handlers Ruud High Efficiency Air Handler RHLL- Series X-1 (ECM) Efficiencies up to 16 SEER RHLL feature an X-1 (ECM) motor which provides enhanced SEER performance with most Ruud outdoor units. Versatile

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH2SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

S/T Ratio. Input BTU/h

S/T Ratio. Input BTU/h SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

BHH Product Specifications

BHH Product Specifications BHH Product Specifications HORIZONTAL BELT DRIVE DIRECT EXPANSION BLOWER COIL UNITS ALL S 3, 4, and 5 Ton 208/230 3 60 and 460 3 60 supply voltage Units are ETL listed to U.S. and Canadian safety standards

More information