1 Air Handlers Rheem High Efficiency Air Handler /RHT- Series Constant Torque (ECM) Efficiencies up to 16 SEER /RHT feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile -way convertible design for upflow, downflow, horizontal left and horizontal right applications. Factory-installed indoor coil. Sturdy cabinet construction with 1.0 inch [. mm] of foil faced insulation for excellent sound and insulating characteristics. Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L. and cul requirements for service disconnect. 1 1 / ton [. kw] through ton [17.6 kw] models are between 1 / to 7 inches [1080 to 18 mm] tall and inches [9 mm] deep. All models meet or exceed 0 to 00 CFM [16 to 189 L/s] per ton at. inches [.7 kpa] of external static pressure. Enhanced airflow up to.7" external static pressure. Evaporator is constructed of aluminum fins bonded to internally grooved aluminum tubing. Suitable for application in mobile homes. Cabinet air leakage less than.0% at 1.0 inch H O when tested in accordance with ASHRAE Standard 19. FORM NO. H11- REV.
2 Engineering Features Engineering Features /RHT- Series The most compact unit design available, all standard heat air handler models only 1 / to 7 inches [1079 to 18 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check. Coils have copper sweat refrigerant connections. Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to inches [1 mm] for 1 1 / inch [8 mm] conduit. Front refrigerant and drain connections.
3 Number Identification R H 1 T 17 S T A N A A *** Option Code (see ADS-80) Blank = None Minor Series A = First Voltage A = 11/1/60 D = 80V//60 J = 08/0/1/60 Controls C = Communicating N = Non-Communicating Major Series A = First Metering Device T = TEV E = EEV P = Piston Coil Efficiency S = Standard M= Medium H = High Width 17 = 17." [1.8 mm] ( CFM) 1 = 1" [. mm] ( CFM) =." [609.6 mm] ( CFM) Nominal Capacity = 18,000 [.7 kw]-,000 [7.0 kw] BTU/H 6 = 0,000 [8.79 kw]-6,000 [10. kw] BTU/H 8 =,000 [1.1 kw]-8,000 [1.06 kw] BTU/H 60 = 60,000 [17.8 kw] BTU/H Type T = Constant Torque (ECM) Stages of Air Flow 1 = Single = Two Stage Product Category H = Air Handler Rheem Available s at 11V A Voltage 17STANAA 617STANAA 61MTANAA 61HTANAA 81STANAA 81MTANAA 601STANAA 8STANAA 60STANAA Available s at 08V J Voltage 17STANJA 617STANJA 61MTANJA 61HTANJA 81MTANJA 81STANJA 8STANJA 601STANAA 60STANJA RHT1MTANJA RHT61MTANJA RHT8MTANJA RHT60STANJA Available s at 80V D Voltage 60STANDA
4 Unit Dimensions ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE HIGH VOLTAGE CONNECTION 7/8 [. mm], 1/ [7.8 mm], 11/ [0 mm] DIA. KNOCKOUTS. SUPPLY AIR 10 /16 [6 mm] NOTE: CLEARANCE REQUIRED IN FRONT OF UNIT FOR FILTER AND COIL MAINTENANCE. W Air Dimensional Data LOW VOLTAGE CONNECTION /8 [1.9 mm] AND 7/8 [. mm] KNOCKOUT A Return Air Opening Dimensions Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches) /8 19 / 1 19 /8 19 / 7 /8 19 / H AUXILIARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) HORIZONTAL APPLICATION ONLY PRIMARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) AUXILIARY DRAIN CONNECTION / [19.1 mm] FEMALE PIPE THREAD (NPT) UPFLOW/DOWNFLOW APPLICATION ONLY LIQUID LINE CONNECTION COPPER (SWEAT) 19 1 / [9 mm] RETURN AIR OPENING 1 11 /16 [1 mm] VAPOR LINE CONNECTION COPPER (SWEAT) UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. HORIZONTAL ADAPTER KIT VAPOR LINE CONNECTION AUXILIARY HORIZONTAL DRAIN CONNECTION 1 /16 [11 mm] 1 /8 [10 mm] 1 /16 [76 mm] 1 /16 [8 mm] 11 /8 [9 mm] 1 1 /16 [7 mm] 1 /8 [ mm] 1 /16 [71 mm] 1 / [1 mm] /8 [16 mm] UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. ( ) Designates Unit with Double Coil Cabinet PRIMARY DRAIN CONNECTION AUXILIARY UPFLOW/DOWNFLOW DRAIN CONNECTION LIQUID LINE CONNECTION VERTICAL DRAIN PAN
5 Dimensional Data Unit Dimensions & Weights Refrigerant Connections [ ] Air Designates Flow Metric Conversions Unit Weight/Shipping Weight Sweat (In.) [mm] ID Unit Unit Supply CFM (Nom.) [L/s] (Lbs.) [kg] Size Width Height Duct ( ) Designates Unit with Double Coil Cabinet W In. [mm] H In. [mm] A In. [mm] Unit With Unit Dimensions Liquid & WeightsVapor Lo Hi Coil (Max. KW) 17ST /8 [9.] / [19.0] 17 1 / [] 1 / [1080] 16 1 / [06] 600 [8] 800 [78] 9/106 [/8] 617ST /8 [9.] / [19.0] 17 1 / [] 1 / [1080] 16 1 / [06] 1000 [7] 100 [66] 96/110 [/0] 61HT /8 [9.] 7/8 [.] 1 1 / [] 7 1 / [18] 19 1 / [9] 1000 [7] 100 [66] 17/19 [6/68] 61MT /8 [9.] 7/8 [.] 1 1 / [] 0 1 / [18] 19 1 / [9] 1000 [7] 100 [66] 16/1 [7/6] 81MT /8 [9.] 7/8 [.] 1 1 / [] 7 1 / [18] 19 1 / [9] 100 [661] 1600 [7] 19/11 [6/68] 81ST /8 [9.] 7/8 [.] 1 1 / [] 0 1 / [18] 19 1 / [9] 100 [661] 1600 [7] 18/1 [6/6] 8ST /8 [9.] 7/8 [.] 1 / [6] 1 / [110] 1 / [8] 1600 [7] 1/160 [6/7] 601ST /8 [9.] 7/8 [.] 1 1 / [] 7 1 / [18] 19 1 / [9] 1600 [7] 17 [81] 19/11 [6/68] 60ST /8 [9.] 7/8 [.] 1 / [6] 1 / [110] 1 / [8] 1800 [80] 19/176 [7/80] *Maximum dehumidification airflow. Unit Dimensions & Weights Size RHT Refrigerant Connections Air Flow Sweat (In.) [mm] ID Unit Unit Supply CFM (Nom.) [L/s] Width Height Duct Liquid Vapor W In. [mm] H In. [mm] A In. [mm] Lo Hi Unit Weight/Shipping Weight (Lbs.) [kg] Unit With Coil (Max. KW) 1MT /8 [9.] / [19.0] 1 1 / [] 1 / [1080] 19 1 / [9] [8] 700 [0] 111/16 [0/7] 61MT /8 [9.] 7/8 [.] 1 1 / [] 0 1 / [18] 19 1 / [9] 800 [77] 100 [9] 19/1 [9/66] 8MT /8 [9.] 7/8 [.] 1 / [6] 1 / [110] 1 / [8] 100 [9] 100 [660] 18/16 [8/66] 60ST /8 [9.] 7/8 [.] 1 / [6] 1 / [110] 1 / [8] 100 [66] 1600 [7] 161/178 [7/81] 6
6 Airflow Directional Data Airflow Directional Data UPFLOW DOWNFLOW HORIZONTAL LEFT HAND AIRFLOW HORIZONTAL RIGHT HAND AIRFLOW 7
7 Airflow Performance Data Airflow Performance Airflow performance data is based on cooling performance with a coil and no filter in place. Select performance table for appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows operation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. For optimum blower performance, operate the unit in the. [8 mm] to.7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of.1 inch [ mm] W.C. external static range. Airflow Operating Limits Cabinet Width 17 17/1 Cooling BTUH x 1,000 Cooling Tons Nominal Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (7. CFM [18 L/s]/1,000 BTUH) (0 CFM [1 L/s]/Ton Nominal) Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (. CFM [16 L/s]/1,000 BTUH) (00 CFM [189 L/s]/Ton Nominal) Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (0.0 CFM [1 L/s]/1,00 BTUH) (60 CFM [170 L/s]/Ton Nominal) Maximum kw Electric Heating & Minimum Electric Heat CFM [L/s] [19] 600 [8] 0 [] 1 87 [0] [] 800 [78] 70 [0] [91] [1] 1000 [7] 900 [] [8] [67] 100 [66] 1080 [10] [97] [7] 100 [661] 160 [9] [] [80] 1600 [7] 10 [680] 10 [709] [80] 1600 [7] 10 [680] 10 [709] Maximum Electric Heat Rise F [ C] 80 [6.7] 6 [17.] 66 [18.9] 1 [10.6] 9 [9.] 0 [10] 0 [10] [911] 1800 [80] 160 [76] [786] [1.] 8
8 Airflow Performance Data 11V/08V/0V/60V Airflow Performance Data (Constant Torque (ECM) ) No. 17ST 17ST with 1 kw 17ST 17ST with 1 kw 617ST No 617ST with 18 kw 617ST No 617ST with 18 kw Tonnage Application 1. Ton 1. Ton Ton Ton. Ton. Ton Ton Ton From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 68/8 [/9 L/s] 68/8 [/9 L/s] 88/697 [0/9 L/s] 68/8 [/9 L/s] 9/108 CFM [1/1 L/s] 910/109 CFM [9/00 L/s] 110/17 CFM [/60 L/s] 110/10 CFM [1/90 L/s] Blower Size/ HP [W] CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] # of 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM 87 [9] 71 [66] 608 [87] [61] 8 [9] RPM Watts / HP [9] CFM 68 [] 61 [90] 7 [70] RPM Watts CFM 81 [8] 69 [6] 89 [78] [] 67 [0] RPM Watts / HP [9] CFM 808 [81] 69 [97] 8 [76] RPM Watts CFM 90 [6] 86 [99] 788 [7] 7 [0] 679 [0] RPM Watts / HP [9] CFM 88 [76] 816 [8] 770 [6] RPM Watts CFM 88 [16] 87 [90] 769 [6] 7 [1] 661 [1] RPM Watts / HP [9] CFM 8 [9] 791 [7] 76 [] RPM Watts CFM 109 [16] 100 [96] 1017 [80] 977 [61] 9 [1] RPM Watts / HP [7] CFM 108 [1] 100 [91] 1001 [7] RPM Watts CFM 1068 [0] 10 [8] 99 [68] 9 [9] 910 [9] RPM Watts / HP [7] CFM 109 [00] 101 [79] 976 [61] RPM Watts CFM 170 [99] 17 [8] 1199 [66] 116 [0] 110 [] RPM Watts / HP [7] CFM 17 [60] 1 [87] 111 [71] RPM Watts CFM 1 [88] 11 [7] 117 [] 110 [8] 110 [1] RPM Watts / HP [7] CFM 10 [90] 119 [7] 1186 [60] RPM Watts
9 Airflow Performance Data 11V/08V/0V/60V Airflow Performance Data (Constant Torque (ECM) ) (con t.) No. 61MT No 61MT with 18 kw 61MT No 61MT with 18 kw Tonnage Application. Ton. Ton &. Ton &. Ton From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 8/110 CFM [0/1 L/s] 88/1016 CFM [91/79 L/s] 1070/188 CFM [0/608 L/s] 10/17 CFM [9/9 L/s] Blower Size/ HP [W] # of 1/ HP [7] 1/ HP [7] 1/ HP [7] 1/ HP [7] CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM 107 [06] 1016 [79] 96 [] 906 [8] 8 [0] RPM Watts CFM 110 [1] 109 [00] 1000 [7] RPM Watts CFM 10 [9] 988 [66] 96 [] 880 [1] 88 [91] RPM Watts CFM 1016 [79] 961 [] 90 [7] RPM Watts 6 CFM 16 [97] 1 [77] 1171 [] 111 [] 1070 [0] RPM Watts CFM RPM 97 [608] 101 [87] 10 [66] Watts 6 71 CFM 1 [8] 119 [6] 11 [9] 108 [1] 10 [9] RPM Watts CFM 17 [9] 11 [7] 1169 [] RPM Watts Notes: Constant Torque motor speed changes. All Constant Torque motors have speed tabs. tab 1 is for continuous fan. tab (low static) and tab (high static) are for lower tonnage. tab (low static) and tab (high static) are for higher tonnage. Constant Torque air handlers are always shipped from factory at tab, except for -8, which is set at tab. For instance, (-)H1T-HM17JA is always shipped at high static -ton airflow ( tab ). To change to 1.-ton airflow, move the blue wire to tab or on the Constant Torque motor. The low static tab (lower tonnage) and (higher tonnage) are used for external static below 0." WC. The high static tab (lower tonnage) and (higher tonnage) are used for external static exceeding 0." WC. Move the blue wire to the appropriate tab as required by the application needs. The airflow for continuous fan ( tab 1) is always set at 0% of the tab. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater (Airflow without heater Airflow with maximum heater) x (N kw/maximum heater kw) 10
10 Airflow Performance Data 11V/08V/0V/60V Airflow Performance Data (Constant Torque (ECM) ) (con t.) No. 81ST No 81ST with 0 kw 81ST No 81ST with kw 8ST No 8ST with kw 60ST No 60ST with 0 kw Tonnage Application. Ton. Ton Ton Ton Ton Ton Ton Ton From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 17/17 CFM [61/68 L/s] 197/1 CFM [61/69 L/s] 1/16 CFM [7/781 L/s] 19/161 CFM [706/76 L/s] 1/17 CFM [79/817 L/s] 10/169 CFM [710/798 L/s] 179/190 CFM [81/899 L/s] 1699/186 CFM [80/880 L/s] Blower Size/ HP [W] # of / HP [9] / HP [9] / HP [9] / HP [9] 11x11 / HP [9] 11x11 / HP [9] 11x11 / HP [9] 11x11 / HP [9] CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM 17 [69] 1 [681] 101 [661] 17 [68] 17 [61] RPM Watts CFM 17 [68] 1 [676] 10 [66] RPM Watts CFM 1 [676] 10 [66] 161 [6] 1 [69] 197 [61] RPM Watts CFM 1 [69] 100 [61] 167 [98] RPM Watts CFM 166 [786] 161 [770] 1601 [76] 17 [7] 1 [7] RPM Watts CFM 16 [781] 16 [766] 16 [78] RPM Watts 00 1 CFM 16 [767] 191 [71] 161 [77] 1 [7] 19 [706] RPM Watts CFM 161 [76] 18 [78] 1 [719] RPM Watts CFM 178 [8] 1669 [788] 169 [77] 199 [7] 1 [79] RPM Watts CFM 17 [817] 168 [79] 160 [769] RPM Watts CFM 1708 [806] 169 [769] 199 [7] 19 [76] 10 [710] RPM Watts CFM 169 [798] 16 [77] 190 [70] RPM Watts CFM 190 [898] 186 [879] 1809 [8] 1781 [80] 179 [81] RPM Watts CFM 190 [899] 1866 [881] 18 [86] RPM Watts CFM 186 [879] 18 [860] 1769 [8] 171 [8] 1699 [80] RPM Watts CFM 186 [880] 186 [86] 179 [86] RPM Watts
11 Airflow Performance Data 11V/08V/0V/60V Airflow Performance Data (Constant Torque (ECM) ) (con t.) No. 60ST No 60ST with 0 kw Tonnage Application & Ton & Ton From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 117/1699 CFM [716/801 L/s] 18/1661 CFM [700/78 L/s] Blower Size/ CFM [L/s] Air Delivery/RPM/Watts (No Filter) HP [W] External Static Pressure Inches W.C. [kpa] # of 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM 170 [800] 1661 [70] 16 [770] 17 [71] 117 [91] RPM x11 Watts / HP [9] CFM 1697 [801] 166 [777] 1601 [76] RPM Watts CFM 1669 [788] 16 [767] 196 [7] 17 [7] 18 [700] RPM x11 Watts / HP [9] CFM 1661 [78] 1611 [760] 166 [79] RPM Watts Notes: All 08/0V PSC motors have voltage taps for 08 and 0 volts. All 08/0V PSC motors are shipped on high speed and 0 volts. If the application external static is less than 0." WC, adjust the motor speed to the low static speed as described below: Unplug the black motor wire off the relay on the control board and plug in the red motor wire. Replace the cap on the black motor wire. Voltage change (08/0V motors): Move the orange lead to transformer 08V tap from 0V tap. Replace the wire cap on 0V tap. Unplug the purple motor wire off the transformer and plug in the yellow motor wire. Replace the cap on the purple motor wire. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater - (Airflow without heater - Airflow with maximum heater) x (N kw/maximum heater kw) 1
12 Airflow Performance Data 11V/08V/0V/80V Airflow Performance Data (Constant Torque (ECM) ) (con t.) No. 61H 61H 18 Kw Heat 61H 61H 18 Kw Heat 81M 81M 0 Kw Heat 81M Nonimal Cooling Capacity Tons.... Manufacturer Recommended Air-Flow Range (Min/Max) CFM Blower Size/ HP [W] # of 1/ HP [7] 1/ Hp [7] 1/ Hp [7] 1/ Hp [7] / Hp [9] / Hp [9] / Hp [9] From Factory CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts
13 Airflow Performance Data 11V/08V/0V/80V Airflow Performance Data (Constant Torque (ECM) ) (con t.) No. 81M 0 Kw Heat 601S 601S 0 Kw Heat 601S 601S 0 Kw Heat Nonimal Cooling Capacity Tons & & Manufacturer Recommended Air-Flow Range (Min/Max) CFM Blower Size/ HP [W] # of / Hp [9] / Hp [9] / Hp [9] / Hp [9] / Hp [9] From Factory CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.0] 0. [.0] 0. [.07] 0. [.10] 0. [.1] 0.6 [.1] 0.7 [.17] CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts CFM RPM Watts
14 Electrical Data Electrical Data Blower Only No Electric Heat Voltage Application Phase* Hertz HP [W] RPM s Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector 17ST 1/ [9] ST 1/ [7] MT/61H 08/0 1 & 60 1/ [7] ST/81M/601S / [9] ST/8ST / [9] ST 1/ [9] ST 1/ [7] MT/61H / [7] ST/81M/601S / [9] ST / [9] ST / [9] * Blower motors are all single phase motors. 1
Rheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable
More informationFORM NO. HSC-543 AIR HANDLERS
FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure
More informationRuud High Efficiency Air Handler
Air Handlers Ruud High Efficiency Air Handler RHLL- Series X-1 (ECM) Efficiencies up to 16 SEER RHLL feature an X-1 (ECM) motor which provides enhanced SEER performance with most Ruud outdoor units. Versatile
More informationRheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor
Air Handlers Rheem Air Handlers RHLP- Standard Efficiency X-13 (ECM) Motor RHLP features an X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 1 1 /2 ton [.3 kw] through
More informationAIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.
FORM NO. H22-523 REV. 4 Supersedes Form No. H22-523 Rev. 3 AIR HANDLERS AIR HANDLERS UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant Features earth friendly
More informationAIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features
FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient
More informationELECTRIC HEAT AIR HANDLERS
ELECTRIC HEAT AIR HANDLERS 208/230V 1 1 /2 to 5 TONS High efficiency series for R-22 Certain models feature GE s new X-13 motor for enhanced SEER performance with most outdoor condensing units Multi-position
More informationAIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just
More informationAIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available
More informationAIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal
More informationAIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION
FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal
More informationHEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H66-515 Supersedes Form No. H66-5 Rev. 1 HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35 inches [889 mm] tall and 22 inches
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)
FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationCFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationBCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY
PRODUCT SPECIFICATIONS APPLICATION 2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (11/2018) INSTALLATION One piece design Smaller profile for closet
More information12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT
Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available
More informationCased/Uncased Coils For Gas And Oil Furnaces
MODEL: TCF Cased/Uncased Coils For Gas And Oil Furnaces FORM NO. CSC-224 REV. 1 Sure Comfort TCF Cased/Uncased Coils For Gas And Oil Furnaces (TXV Metering Device Shown) Featuring Industry Standard R-410A
More informationProduct Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationCFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)
ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV
More informationModular Variable Speed Air Handlers
Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS
FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed
More informationHMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS HMG Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG Series of air handlers, when combined with our heat pump or air conditioner,
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFP- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,600 CFM [283-755 L/s] Rheem Indoor Coils are designed for use
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More informationProduct Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES
FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system
More informationMERIT Series R-410A - Upflow / Horizontal - Variable Speed
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit
More informationRCBA- MULTIFLEX INDOOR COILS
FORM NO. C11-207 REV. 3 Supersedes Form No. C11-207 Rev. 2 RCBA- MULTIFLEX INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Rheem Value Series Indoor Coils are designed for use with Rheem Value Series
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationAVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...
More informationINDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]
FORM NO. C11-206 REV. 13 Supersedes Form No. C11-206 Rev. 12 INDOOR S RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Rheem Indoor Coils are designed
More informationA I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S
P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS
COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed
More informationBCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY
PRODUCT SPECIFICATIONS STANDARD AIR HANDLER FORM NO. -100 (05/2014) APPLICATION 1 1/2-5 ton systems Upflow and horizontal (counterflow capable with kits) Sequenced for demand management External access
More informationBCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY
PRODUCT SPECIFICATIONS APPLICATION 1 1/2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (12/2018) INSTALLATION 1 piece design Smaller profile for
More informationFEM4P, FSM4P, FSU4P. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P, FSU4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering
More informationINDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
More informationINDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]
FORM NO. C22-206 REV. 14 Supersedes Form No. C22-206 Rev. 13 INDOOR S RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR S AIRFLOW CAPACITIES 600-2000 CFM [218-944 L/s] Ruud Indoor Coils are designed
More informationHMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS HMG*T Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG*T series of air handlers, when combined with our heat pump or air conditioner, offer
More informationELITE Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX7UH ELITE Series R-0A - Upflow / Horizontal Bulletin No. 08 March 0 Supersedes October 0 Nominal Capacity -. to Tons Optional Electric Heat -. to kw MODEL NUMBER
More informationINDOOR COILS. RCFM- featuring New Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-212 REV. 4 Supersedes Form No. C11-212 Rev. 3 INDOOR COILS RCFM- featuring New Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900
More informationMulti-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor
Multi-Position Air Handler with Energy-Saving Motor ½ to Tons Standard Features Suitable for use with refrigerants R-0A and R- All-aluminum evaporator coil Check flowrater expansion device for cooling
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More informationFEM4X, FSM4X, FSU4X. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT, FSU4X Product Specifications FAN COILS ALL MODELS Available for Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin
More informationDimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT
ENVIRONMENTALLY SOUND REFRIGERANT B Series Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two--stage outdoor units Available for Environmentally Sound R--410A systems
More information135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944)
ENVIRONMENTALLY SOUND REFRIGERANT Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for Environmentally Sound R 410A systems Bolt
More informationB6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS B6BMMX Series Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The B6BMMX series of air handlers, when combined with our heat pump or air conditioner,
More informationFMU4X, FMC4X FMU4Z, FMC4Z
HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,
More informationProduct Data. Convertible Air Handlers 1 1/2 5 Ton D-EN. September 2016
Product Data Convertible Air Handlers 1 1/2 5 Ton TEM6A0B24H21S TEM6A0B30H21S TEM6A0C36H31S TEM6A0C42H41S TEM6A0C48H41S TEM6A0D48H41S TEM6A0C60H51S TEM6A0D60H51S The TEM6 series air handler is designed
More informationProduct Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil
FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil
More informationPHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only
More informationDESCRIPTION FEATURES
TECHNICAL GUIDE MODELS: N*AH Modular Air Handlers For use w / Split System Cooling & Heat Pump 600-2000 CFM Blowers 2-5 Ton Coils Optional 1 & 3 Electric Heaters DESCRIPTION This unique modular system
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFN- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Ruud Indoor Coils are designed for use
More informationQ7RE Series Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Ruud Indoor Coils are designed for use
More informationMB6(B,E,V)M Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Modular Indoor Blower 13+ SEER Residential System. Additional MB6EM Features:
TECHNICAL SPECIFICATIONS MB6(B,E,V)M Series Modular Indoor Blower 13+ SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The MB6 Series Modular Indoor Blower offers exceptional flexibility
More informationBCE3V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY
PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER FORM NO. -100 (03/2017) APPLICATION 1.5-5 ton systems Upflow and horizontal Sequenced for demand management External access to heater circuit breakers INSTALLATION
More informationMF Product Specifications
Product Specifications MODULAR ELECTRIC FURNACE 2, 3, 4, and 5 TONS FEATURES Modular Blower Cabinet, Air Conditioning or Heat Pump ready Upflow, horizontal right or left applications Downflow requires
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCF- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] (TXV Metering Device Shown) Ruud Indoor
More informationB6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS 6EMMX Series Air Handler with TXV 14-15 SEER Residential System 18,000-60,000 tuh (Heat Pump & Air Conditioner) R-410A Refrigerant The 6EMMX Series of air handlers, when combined
More informationCFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH
CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool
More informationCASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. CFJ-224 Supersedes Form No. PTZ-789 CASED/UNCASED COILS FOR GAS AND OIL FURNACES FCC SERIES featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] (TXV Metering
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM6A0B24H21SB TEM6A0B30H21SB TEM6A0C36H31SB TEM6A0C42H41SB TEM6A0C48H41SB TEM6A0D48H41SB TEM6A0C60H51SB TEM6A0D60H51SB The TEM6 series air handler is designed
More information14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON
14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech
More informationB Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor
SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features
More informationProduct Data. Convertible Air Handlers 1 1/2 5 Ton B-EN. August 2015
Product Data Convertible Air Handlers 1 1/2 5 Ton TEM6A0B24H21S TEM6A0B30H21S TEM6A0C36H31S TEM6A0C42H41S TEM6A0D48H41S TEM6A0D60H51S The TEM6 series air handler is designed for installation in a closet,
More information13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh
PGF3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency Copeland scroll compressor, 4 & 5 ton have two--stage
More informationRPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.
RPGE13 Product Specifications 13 SEER Gas / Electric Residential Packaged Unit Form No. RPGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin
More informationP7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner
TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency
More informationModular Variable Speed Air Handlers
Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 2 1/2-5 Ton 2TEE3C31A1000A 2TEE3C37A1000A 2TEE3C40A1000A 2TEE3C49A1000A 2TEE3C65A1000A 4TEE3C31A1000A 4TEE3C37A1000A
More informationAIR CONDITIONERS WA16 SERIES
FORM NO. A66-222 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM6A0B24H21S TEM6A0B30H21S TEM6A0C36H31S TEM6A0C42H41S TEM6A0C48H41S TEM6A0D48H41S TEM6A0C60H51S TEM6A0D60H51S The TEM6 series air handler is designed
More informationEBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES. Model Number
ENVIRONMENTALLY SOUND REFRIGERANT EBP Product Specifications EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES Multipoise design for maximum versatility 2 speed motor in 24 and 36 sizes 3 speed motor in
More informationCFM Range Tons x 21 1 / 8 x x 21 FVM*X4800A 48, FVM*X6000A 60, x 24 x x
FVM Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for R 22 or Environmentally Sound R 410A systems Bolt on, hard shut off TXV
More informationPHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP 400v- 3-50 Hz FOR EXPORT USE Combination heating and cooling, self-contained for year-round comfort. Systems install on rooftop
More informationP7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner
TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self
More informationGPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER
Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit
More informationUp to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL
N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS HEAT PUMP MODELS: F2RP/F2FP018 THRU 060 F3RP/F3FP018 THRU 060(T) FXRP024 THRU 060 COOLING MODELS F2RC/F2FC024 THRU
More informationGQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged
More informationP3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh
TECHNICAL SPECIFICATIONS P3R(A,C) Series Single Packaged Air Conditioner, Single Phase P3RA-10 SEER 2 thru 5 Ton Units Cooling: 24,000 to 59,000 Btuh P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800
More informationPA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE
PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on
More informationGPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h
Cooling Capacity: 23,000-56,000 BTU/h GPC14M Packaged Air Conditioner 2 through 5 Tons / 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heat
More informationQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS
TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged
More informationASPT Multi-Position Air Handler
Multi-Position Air Handler with Energy-Saving Motor ½ to Tons Standard Features Direct-drive, multi-speed ECM motor Internal factory-mounted TXV valve Transformer and blower time-delay on all units All-Aluminum
More informationB6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS 6VMMX Series Air Handler with TXV 18,000-60,000 tuh (Heat Pump & Air Conditioner) The 6VMMX Series of air handlers, when combined with our heat pump or air conditioner, offers
More informationMV Product Specifications
Product Specifications MODULAR VARIABLE SPEED BLOWER CABINET 2, 3, 4, and 5 TONS FEATURES Variable Speed modular blower Supports two stage outdoor units Dehumidification Speed: 80% Airflow Efficient low
More informationBCS2**V. Enhanced Air Handler APPLICATION INSTALLATION CABINET ACCESSORIES COMPONENTS
Enhanced Air Handler BCS2**V APPLICATION 2-5 ton sizes Upflow and horizontal (counterflow capable with kit) Sequenced for demand management External access to heater circuit breakers INSTALLATION 1 Piece
More informationARUF. Multi-Position Air Handler. 1½ to 5 Tons. Construction
½ to 5 Tons Multi-Position Air Handler with new SmartFrame Construction Standard Features All-aluminum evaporator coil Check flowrater expansion device for cooling-only and heat pump applications Direct-drive,
More informationSTELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING
(598) STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING HEAT PUMP S: F2RP / F2FP018 THRU 060 COOLING S: F2RC / F2FC018 THRU 036 VARIABLE SPEED : F2FV060 DESCRIPTION This fan coil
More informationBCS2S. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS ACCESSORIES.
Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION 2-5 ton sizes Upflow and horizontal (counterflow capable with kit) Sequenced for demand management External access to heater
More informationP6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES
TEHNIAL GUIDE SINGLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLING & HEAT PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 DESRIPTION This fan coil line offers the ultimate in application flexibility.
More information