Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number *

Size: px
Start display at page:

Download "Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number *"

Transcription

1 COMMERCIAL PAE Product Specifications Ashrae 90. EFFICIENCY PACKAGE A/C UNIT - 80 to 232 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, electrically and mechanically independent circuits. Refrigerant filter drier and evaporator freeze thermostat High and low pressure switches for excellent compressor protection. BUILT TO LAST Pre--painted galvanized steel cabinet for long life and quality appearance. Commercial strength base rails with built--in rigging capability. Non--corrosive, sloped condensate drain pan, meets ASHRAE EASY TO INSTALL AND SERVICE Electric cooling, self contained for year-round comfort. Unit shipped ready for downflow applications with conversion to horizontal airflow accomplished with accessory horizontal discharge roof curb. Thru--the--base utility connections. 2% Manual outside air damper. Two inch return air filters. WARRANTY Year compressor limited warranty Year parts limited warranty UNIT PERFORMANCE DATA COOLING Rated Unit Model Capacity Unit Dimensions Weight Number * BTUH E.E.R IPLV HXWXL PAE80H000A 80, x 86 -/8 x 87-3/8 0 PAE80L000A 80, x 86 -/8 x 87-3/8 0 PAE80S000A 80, x 86 -/8 x 87-3/8 0 PAE20H000A 204, x 86 -/8 x 87-3/8 70 PAE20L000A 204, x 86 -/8 x 87-3/8 70 PAE20S000A 204, x 86 -/8 x 87-3/8 70 PAE240H000A 232, /4 x 86 -/8 x 87-3/8 770 PAE240L000A 232, /4 x 86 -/8 x 87-3/8 770 PAE240S000A 232, /4 x 86 -/8 x 87-3/8 770 * Unit voltage: H = 208/230v, L = 460v, S = 7v /24/07

2 Table of Contents Page Features/Benefits... Model Number Nomenclature... 2 Unit Specifications Dimensions Performance Data Typical Installations... 4 Accessories Operating Sequence and Application Data Guide Specifications MODEL NUMBER IDENTIFICATION GUIDE MODEL NUMBER P A E 80 H 000 A PRODUCT FAMILY Package Units TYPE H= Heat Pump G = Gas/Electric A = Air Conditioner OPTIONS VOLTAGE / PHASE / HERTZ H = 208/ Sales Code DESIGN SERIES L = S = COOLING CAPACITY (NOMINAL BTUH) 80 = Ton 20 = 7--/2 Ton 240 = 20 Ton 2

3 UNIT SPECIFICATIONS - MODELS COOLING PAE80H PAE80L PAE80S PAE20H PAE20L PAE20S ARI Rated Capacity Btuh (Net) 80, ,000 Nominal Tons 7 -/2 Standard CFM EER IPLV.6 0. Sound Rating (Bels) Base Unit Operating Weights (lbs) 0 70 ELECTRICAL Volts/ 3 Phase/ 60Hertz 208/ / Voltage Range Min/Max 87 / / 08 8 / / / 08 8 / 633 Power Supply MCA 82 / / Power Supply MOCP* 0 / / COMPRESSOR SCROLL / COPELAND Quantity...Model...ZR49KC /...ZR72KC...ZR08KC /...ZR94KC No.ofCircuits 2 2 RLA / LRA Circuit # 32. / / / / 22. / 4 2. / 80 Circuit # / / / / / / 80 Oil (Oz.) per circuit 8, 60 06, 8 REFRIGERATION TYPE R-22 Expansion Device TXV TXV Operating Charge (lb. oz. ) * CKT = 9-6 CKT 2 = 3-4 CKT = 9-8 CKT 2 = 9-2 CONDENSER FAN Propeller Type Nominal CFM 0,00 0,00 Quantity..Diameter (in.) Motor Hp...RPM (each) / / Watts Input (Total) FLA CONDENSER COIL Cross Hatched 3/8 in. Copper Tubes, Aluminum Lanced Rows...Fin/In Total Face Area (Sq. Ft..) EVAPORATOR COIL Cross Hatch 3/8 in. Copper Tubes, Aluminum Lanced, Face Split Rows...Fins/Inche Total Face Aea (sq. ft.) EVAPORATOR FAN Centrfugal Type Quantity...Size (in.) x x 2 Type Drive Belt Belt Nominal CFM Motor Hp, RPM, Max. Continuous Bhp, 74, 6.3, 74, 6.3, 74, 6.3, 74,.9, 74,.9, 74,.9 FLA (Each).8 / / Motor Frame Size 84T 84T Fan RPM Range Motor Bearing Ball Ball Maximum Allowable RPM 0 0 Motor Pulley Pitch / Diameter Min/Max. (in.) Motor Shaft Diameter (in.) -/8 -/8 Fan Pulley Pitch Diam (in) Belt, Quantity...Type... Length (in.).bx.0.bx.0 Pulley Center Line Distance (in) Speed Change per Full Turn of Movable Pulley Flange (RPM) Pulley Max. full Turns From Closed Postion 4 Factory Setting Factory Speed Setting RPM Fan Shaft Diam. at Pulley -7/6-7/6 SEE LEGENDS AND NOTES ON FOLLOWING PAGES 3

4 UNIT SPECIFICATIONS - MODELS COOLING PAE240H PAE240L PAE240S ARI Rated Capacity Btuh (Net) 232,000 Nominal Tons 20 Standard CFM 6600 EER 9.7 IPLV 0.3 Sound Rating (Bels) 9. Base Unit Operating Weights (lbs) 700 ELECTRICAL Volts/ 3 Phase/ 60Hertz 208/ Voltage Range Min/Max 87 / / 08 8 / 633 Power Supply MCA 24 / Power Supply MOCP* 0 / COMPRESSOR SCROLL / COPELAND Quantity...Model...ZR2KC /...ZR08KC No.ofCircuits 2 RLA / LRA Circuit # 42.0 / / / 80 Circuit # / / 4 3. / 80 Oil (Oz.) per circuit 06, 06 REFRIGERATION TYPE R-22 Expansion Device TXV Operating Charge (lb. oz. ) * CKT = 9-7 CKT 2 = 3-9 CONDENSER FAN Propeller Type Nominal CFM 4,200 Quantity..Diameter (in.) Motor Hp...RPM (each)...07 Watts Input (Total) 3400 FLA CONDENSER COIL Cross Hatched 3/8 in. Copper Tubes, Aluminum Lanced Rows...Fin/In Total Face Area (Sq. Ft..) 2.7 EVAPORATOR COIL Cross Hatch 3/8 in. Copper Tubes, Aluminum Lanced, Face Split Rows...Fins/Inche 4... Total Face Aea (sq. ft.) 7. EVAPORATOR FAN Centrfugal Type Quantity...Size (in.) x 2 Type Drive Belt Nominal CFM 8000 Motor Hp, RPM, Max. Continuous Bhp 7., 74, , 74, 9. 7., 74, 8.7 FLA (Each) 2.0 / Motor Frame Size 23T Fan RPM Range Motor Bearing Ball Maximum Allowable RPM 0 Motor Pulley Pitch / Diameter Min/Max. (in.) Motor Shaft Diameter (in.) -3/8 Fan Pulley Pitch Diam (in) 9.4 Belt, Quantity...Type... Length (in.).bx.3 Pulley Center Line Distance (in) Speed Change per Full Turn of Movable 37 Pulley Flange (RPM) Pulley Max. full Turns From Closed Postion Factory Setting 3. Factory Speed Setting RPM 20 Fan Shaft Diam. at Pulley -7/6 SEE LEGENDS AND NOTES ON FOLLOWING PAGES 4

5 UNIT SPECIFICATIONS (CONT) MODELS PAE80 PAE20 PAE240 HIGH- PRESSURE SWITCH (psig) Internal Relief (Differential) Cutout Reset (Auto.) LOSS- OF- CHARGE SWITCH (psig) (LOW- PRESS.) Cutout Reset (Auto.) FREEZE PROTECTION THERMOSTAT (F) Opens 30 +/ / /-- Closes 4 +/-- 4 +/-- 4 +/-- RETURN- AIR FILTERS (THROWAWAY) Quantity...Size (in.) x 20 x x 20 x x 20 x x 20 x x 20 x x 20 x 2 Bhp = Brake Horsepower Legend Bels -- Sound Levels EER -- Energy Efficiency Ratio IPLV -- Integrated Part Load Values MCA -- Minimum Circuit Amps MOCP -- Maximum Over--current Protection FLA -- Full Load Amps LRA -- Locked Rotor Amps * -- Fuse or HACR circuit breaker RLA -- Rated Load Amps NOTES:. In compliance with NEC requirements for multimotor and combina-- tion load equipment (refer to NEC Articles 430 and 440), the over-- current protective device for the unit shall be fuse or HACR breaker. Canadian units may be fuse or circuit breaker. 2. Unbalanced 3 -Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent voltage imbalance. % Voltage Imbalance = 00 x max voltage deviation from average voltage average voltage LEGENDS AND NOTES NOTES:. Rated in accordance with ARI Standards 20/240, latest revision (for sizes 090 & 20) or 360, latest revision (for size 0). 2. ARI ratings are net values, reflecting the effects of circulating fan heat. 3. Ratings are based on: Cooling Standard: 80F db, 67F wb indoor entering air temperture and 9F db air entering outdoor unit. IPLV Standard: 80F db, 67F wb indoor entering air temperture and 80F db entering air temperature. EXAMPLE: Supply voltage is AB = 42 v Average Voltage = BC = 464 v 3 AC = 4 v 37 = 3 = 47 Determine maximum deviation from average voltage. (AB) = V (BC) = 7 V (AB) = 2 V Maximum deviation is 7 v. Determine percent voltage imbalance. % Voltage Imbalance = 00 x 7 47 =.3% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT : If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

6 BASE UNIT DIMENSIONS - PAE80,20 Unit Total Weight Corner A Corner B Corner C Corner D Dim A Dim B Dim C lb kg lb kg lb kg lb kg lb kg inches mm inches mm inches mm PAE PAE NOTES:. Dimensions in () are in millimeters. 2. Center of Gravity. 3. Direction of Airflow 4. Ductwork to be attached to accessory roof curb only.. Minimum clearance: Rear: 84 (234) for coil removal. This dimension can be reduced to 48 (29) if conditions permit coil removal from the top. Left side: 48 (29) for proper condenser coil airflow. Front: 48 (29) for control box access. Right Side: 48 (29) for proper operation of damper and power exhaust if so equipped. Top: 72 (829) to assure proper condenser fan operation. Local Codes jurisdiction may prevail. 6. With the exception of clearance for the condenser coil and the damper/power exhaust as stated in Note #, a removeable fence or barricade requires no clearance. 7. Dimensions are from outside of corner post. Allow 0--/6 (8) on each side for top cover drip edge. 7 3 /8 83 / 2 3 / 8 30 / 6 /6 DIA. Hole 8 / / 6 6 / / 6 3 / 6 4 /6 / 6 2 / DIA. HOLE TYPICAL 2 TYPICAL 4 CORNERS / 4 DIA. HOLE TYPICAL 2 / 6 (B) 3 67 / 6 Condensing Coil 0 3 / 6 (A) Supply Air & 3 3 K.o. 2 DIA. K.o. 3 / 8 Return Air 69 7 /8 DIA. Hole 7 7 / 8 / 6 3 / / 8 0 / / / 8 3 & 7 / 8 DIA. K.o. (Field Power) 3 / 8 & 3 / 8 DIA. K.o. (Field Power) 7 /8 DIA. K.o. (Controls) Control Box Access 22 / 6 4 TYP (C) / 2 2 TYP Evaporator Coil 3 / Filters Access Far Side FTP Drain Connection 4 Far Side Only 3 / / / / 6 Alternate Return a 3 3 6

7 BASE UNIT DIMENSIONS - PAE240 Unit Total Weight Corner A Corner B Corner C Corner D Dim A Dim B Dim C lb kg lb kg lb kg lb kg lb kg inches mm inches mm inches mm PAE NOTES:. Dimensions in () are in millimeters. 2. Center of Gravity. 3. Direction of Airflow 4. Ductwork to be attached to accessory roof curb only.. Minimum clearance: Rear: 84 (234) for coil removal. This dimension can be reduced to 48 (29) if conditions permit coil removal from the top. Left side: 48 (29) for proper condenser coil airflow. Front: 48 (29) for control box access. Right Side: 48 (29) for proper operation of damper and power exhaust if so equipped. Top: 72 (829) to assure proper condenser fan operation. Local Codes jurisdiction may prevail. 6. With the exception of clearance for the condenser coil and the damper/power exhaust as stated in Note #, a removeable fence or barricade requires no clearance. 7. Dimensions are from outside of corner post. Allow 0--/6 (8) on each side for top cover drip edge. 8 / / / 3 / 8 DIA. Hole 3 9 / 6 6 / 6 30 / / 6 3 / 6 /6 4 /6 / 6 2 / DIA. HOLE TYPICAL 2 / 4 DIA. HOLE TYPICAL 2 / 6 TYPICAL 4 CORNERS (B) 3 67 / 6 (A) Supply Air Return Air / 8 86 / / 3 & 7 DIA. K.o. (Field Power) / 8 Condensing Coil 0 3 / 6 & 3 3 K.o. 2 DIA. K.o. 3 / 8 7 /8 DIA. Hole / 6 3 / / / 8 3 / 8 & 3 / 8 DIA. K.o. (Field Power) 7 /8 DIA. K.o. (Controls) 4 / 4 2 / Control Box Access 22 / 6 47 / 4 TYP (C) / 2 2 TYP Evaporator Coil 3 / Filters Access Far Side FTP Drain Connection 4 Far Side Only 7 3 / / 6 3 / / 6 Alternate Return

8 EXPANDED PERFORMANCE DATA (COOLING) Ton (GROSS Capacity) Outdoor Ambient Temperature - Degrees F, Dry Bulb Airflow CFM Entering Indoor Air Temperature - Degrees F, Wet Bulb IDB (BF) MBH S/T (0.) KW MBH S/T (0.4) KW MBH S/T (0.2) KW FORMULAS AND NOTES FOR USING EXPANDED PERFORMANCE DATA To find leaving wet bulb and dry bulb from the expanded performance charts, use the following formulas.. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: t /db = t edb - sensible capacity Btuh / (.0 x cfm) t /wb = Wet bulb temp. corresponding to enthalpy of air leaving evaporator coil (h /wb) h /wb = h ewb - total capacity Btuh / (4. x cfm) where h ewb = Enthalpy of air entering evap. coil MBH = Total Capacity (Gross) S/T = Sensible to Total Ratio KW = Compressor Motor Power Input. IDB = Indoor Dry Bulb edb = Entering Dry Bulb ewb = Entering Wet Bulb t /db = Leaving Dry Bulb t /wb = Leaving Wet Bulb h /wb = Enthalpy of Leaving Wet Bulb 3. The SHC is based on 80F edb of air entering evap coil. SHC = Sensible Heat Capacity Below 80F edb, subtract (corr factor x cfm) from SHC. Above 80F edb, add (corr factor x cfm) to SHC. BYPASS FACTOR (BF) LEGEND ENTERING AIR DRY BULB Correction Factor Use formulas shown below Correction Factor =.0 x (-BF) x (edb-80). under 7 over 8 8

9 EXPANDED PERFORMANCE DATA (COOLING) 7 -/2 Ton (Gross Capacity) 9

10 EXPANDED PERFORMANCE DATA (COOLING) 20 Ton (GROSS Capacity) Outdoor Ambient Temperature - Degrees F, Dry Bulb Airflow CFM Entering Indoor Air Temperature - Degrees F, Wet Bulb IDB (BF) MBH S/T (0.0) KW MBH S/T (0.00) KW MBH S/T (0.08) KW FORMULAS AND NOTES FOR USING EXPANDED PERFORMANCE DATA To find leaving wet bulb and dry bulb from the expanded performance charts, use the following formulas.. Direct interpolation is permissible. Do not extrapolate. LEGEND 2. The following formulas may be used: MBH = Total Capacity (Gross) t /db = t edb - sensible capacity Btuh / (.0 x cfm) S/T = Sensible to Total Ratio KW = Compressor Motor Power Input. t /wb = Wet bulb temp. corresponding to enthalpy of IDB = Indoor Dry Bulb air leaving evaporator coil (h /wb) edb = Entering Dry Bulb ewb = Entering Wet Bulb h /wb = h ewb - total capacity Btuh / (4. x cfm) t /db = Leaving Dry Bulb where h ewb = Enthalpy of air entering evap. coil t /wb = Leaving Wet Bulb h /wb = Enthalpy of Leaving Wet Bulb 3. The SHC is based on 80F edb of air entering evap coil. SHC = Sensible Heat Capacity Below 80F edb, subtract (corr factor x cfm) from SHC. Above 80F edb, add (corr factor x cfm) to SHC. ENTERING AIR DRY BULB BYPASS FACTOR (BF) Correction Factor Use formulas shown below Correction Factor =.0 x (-BF) x (edb-80). under 7 over 8 0

11 PAE SERIES EVAPORATOR FAN PERFORMANCE Airflow CFM CIRCULATING BLOWER PERFORMANCE - PAE80 - Standard Motor (Belt Drive)* EXTERNAL STATIC PRESSURE (in. wg) RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts CIRCULATING BLOWER PERFORMANCE - PAE80 (CONTINUED) - Standard Motor (Belt Drive)* Airflow CFM EXTERNAL STATIC PRESSURE (in. wg) RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts LEGEND Watts = Input Watts to motor. Airflow based on dry coil with filters. Standard low--medium static drive range is 873 to 02 rpm. Alternate high--static drive range is 02 to 200. Other rpms require a field--supplied drive. Airflow CFM CIRCULATING BLOWER PERFORMANCE - PAE20 - Standard Motor (Belt Drive)* EXTERNAL STATIC PRESSURE (in. wg) RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts , LEGEND Watts = Input Watts to motor. Airflow based on dry coil with filters. Standard low--medium static drive range is 90 to 09 rpm. Alternate high--static drive range is 069 to 287rpm. Other rpms require a field--supplied drive.

12 PAE SERIES EVAPORATOR FAN PERFORMANCE (CONT.) Airflow CFM CIRCULATING BLOWER PERFORMANCE - PAE240 - Standard Motor (Belt Drive)* EXTERNAL STATIC PRESSURE (in. wg) RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts , CIRCULATING BLOWER PERFORMANCE - PAE240 (CONTINUED) - Standard Motor (Belt Drive)* Airflow CFM EXTERNAL STATIC PRESSURE (in. wg) RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts , LEGEND Watts = Input Watts to motor. Standard low--medium static drive range is 002 to rpm. Alternate high--static drive range is 93 to 369. Other rpms require a field--supplied drive. 2

13 EVAPORATOR FAN DATA FOR PAE80, 20, 240 UNIT PAE80 PAE20 PAE240 EVAPORATOR FAN MOTOR DATA FOR PAE80, 20, 240 Maximum Acceptable Maximum Acceptable Unit Voltage Continuous BHP Operating Watts Maximum Amp Draw 208/ , , , /230.90, , , / , , ,9 0.0 FAN RPM AT MOTOR PULLEY SETTINGS FOR PAE80, 20, 240 MOTOR PULLEY TURNS OPEN* UNIT -/2 2 2-/2 3 3-/2 4 4-/2 -/2 6 PAE80H,L,S * * PAE20H,L,S PAE240H,L,S * * * Due to belt and pulley size, pulley cannot be set to 0 or /2 or this number of turns open. AIR QUANTITY LIMITS FOR PAE80, 20, 240 UNIT Minimum Airflow (Cfm) Maximum Airflow (Cfm) PAE PAE PAE ,000 EVAPORATOR FAN MOTOR EFFICIENCY UNIT Motor Efficiecny % PAE PAE PAE OUTDOOR SOUND POWER SOUND RATING OCTAVE BANDS UNIT (db) PAE80 88 Bels PAE20 88 Bels PAE Bels

14 Disconnect Per NEC. 2% Air Or Economizer Hood TYPICAL INSTALLATIONS Control Wiring Power Wiring Condensate Drain Roof Curb Return Air Supply Air b 4

15 PAE Series ELECTRICAL DATA - ELECTRIC HEAT ACCESSORY Evap. Fan Motor Electric Heater * Power Supply Unit Voltage Qty Model Number HP FLA kw FLA MCA MOCP ** PAE80 AES034EHA AES06EHA AES07EHA PAE80 AES034EHA AES06EHA AES07EHA PAE80 AES32ELA AES0ELA AES080ELA PAE20 AES034EHA AES06EHA AES07EHA PAE20 AES034EHA AES06EHA AES07EHA PAE PAE PAE PAE AES32ELA AES0ELA AES080ELA AES034EHA AES06EHA AES07EHA AES034EHA AES06EHA AES07EHA AES32ELA AES0ELA AES080ELA * Heater capacity (kw) is based on heater voltage of 208 v, 240 v, and 480 v. Heaters are rated at 240 v and 480 v. If power distribution voltage to unit varies from rated heater voltage, heater kw will vary accordingly. To determine heater capacity at actual unit voltage, multiply 240v, 480v capacity by multipliers found at bottom of page. ** Fuse or HACR circuit breaker. MULTIPLICATION FACTORS Heater Rating Voltage ACTUAL HEATER VOLTAGE NOTE: The following equation converts kw of heat energy to Btuh: kw x 3.42 = Btuh. LEGEND FLA - Full Load Amps MCA - Minimum Circuit Amps MOCP - Maximum Overcurrent Protection LRA - Locked Rotor Amps NEC - National Electrical Code NOTES. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker. Canadian units may be fuse or circuit breaker. 2. Ubalanced 3 -Phase Supply Voltage - Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percent of voltage imbalance. % Voltage Imbalance = 00 x (max voltage deviation from average voltage / average voltage) IMPORTANT: If the supply voltage phase imbalance is more than 2 %, contact your local electric company immediately.

16 ACCESSORIES VERTICAL DISCHARGE ROOF CURBS Description Model Number Where Used 4 High AXB060CMA 80, 20, High AXB060CHA 80, 20, 240 HORIZONTAL DISCHARGE ROOF CURBS Description Model Number Where Used 24 High AXB06CHA 80, 20, High w/ Duct AXB6CHA 80, 20, / 6 72 / 6 ECONOMIZER - HORIZONTAL / DOWNFLOW Description Model Number Where Used Fully Modulating AXB060EMA 80, 20, 240 Three Position AXB060EPA 80, 20, 240 6

17 ACCESSORIES (CONT.) COIL PROTECTION Description Model Number Where Used Coil Guard AXB060CGA 80, 20, 240 Hail Guard AXB060HGA 80, 20, 240 AXB060HGA AXB060CGA POWER EXHAUST Description Model Number Where Used 208/230 Volt AXB060PEH 80, 20, Volt AXB060PEL 80, 20, Volt AXB060PES 80, 20, 240 POWER EXHAUST PERFORMANCE DATA Motor Unit Model Volt/Phase/ Hertz Qty HP RPM Cir. Qty LRA FLA MCA Fuse CFM AXB060PEH /3/60 2 3/ ,600 AXB060PEL 460/3/60 2 3/4 07 N/A ,600 AXB060PES 7/3/60 2 3/4 00 N/A ,600 7

18 ACCESSORIES (CONT.) CONCENTRIC DUCT KIT Description Model Number Where Used 8 x 36 AXB60CTA 80, x 48 AXB260CTA 240 CONCENTRIC DIFFUSER Description Model Number Used With Flush Mount AXB0CFA 80, 20 Flush Mount AXB08CFA 240 Step Down AXB0CSA 80, 20 Step Down AXB08CSA 240 G F E 4/2 H D C SEE PERFORMANCE DATA ON NEXT PAGE 2.2 DIFFUSER BOX TRANSITION BOOT 2 B A ANTI-SWEAT GASKET RETURN EGGCRATE GRILLE ALUMINUM DIFFUSER AXB0-8CFA ANTI-SWEAT GASKET F E H D DIFFUSER BOX DOUBLE DEFLECTION GRILL G C TRANSITION BOOT I J B A K RETURN EGGCRATE GRILL AXB0-8CSA DIMENSIONS Model Number A B C D E F G H I J K AXB0CFA 47-/8 47-/8 29-/ /4 38 N/A N/A N/A 8 x 36 AXB08CFA 9-/8 9-/8 3-/ /4 48 N/A N/A N/A 24 x 48 AXB0CSA 47-/8 47-/8 24-/ / /8 4-/2 4-/2 8 x 36 AXB08CSA 9-/8 9-/8 30-/8 7-/2 7-/ /2 48 -/8 7-/2 7-/2 24 x 48 Duct Size 8

19 ACCESSORIES (CONT.) CFA SERIES PERFORMANCE DATA Part No. AXB CFM Static Pressure In. WC Throw Feet Neck Velocity FPM Jet Velocity FPM db Sound Level 0CFA CFA CSA SERIES PERFORMANCE DATA Part No. AXB CFM Static Pressure In. WC Throw Feet Neck / Jet Velocity FPM db Sound Levels 0CSA CSA CSA/CFA NOTES:. All data is based on the Air Diffusion Council guidelines. 2. Throw data is based on Terminal Velocities of 7 FPM using isothermal air. 3. Throw is based on diffuser blades being directed in a straight pattern. 4. Actual sound levels are less than those shown.. Minimum height 9 above floor. FRESH AIR DAMPERS Description Model Number Used With 3% Motorized AXB060FMA 80, 20, DAY PROGRAMMABLE COMMERCIAL THERMOSTAT Model Number Used With , 20, 240 LOW AMBIENT KIT Model Number Used With AXB60LAA 80, 20 AXB260LAA 240 PART NUMBERS FOR APPROVED HIGH STATIC CONVERSIONS* Unit Size (Tons) Voltage Motor Motor Pulley Blower Pulley & 7 -/2 208/230 & 460 No Change Belt Circuit Breaker Circuit Breaker Bracket No Change N/A N/A 7 N/A N/A N/A N/A N/A N/A 20 All Voltages No Change N/A N/A * Available thru service parts only. 9

20 OPERATING SEQUENCE Cooling, Units Without Economizer When thermostat calls for cooling, terminals G and Y are energized. The indoor (evaporator) fan contactor (IFC) and compressor contactor no. (C) are energized, and evaporator--fan motor (IFM), compressor no., and condenser fan(s) start. The condenser fan motor(s) runs continuously while unit is cooling. When the thermostat calls for a second stage of cooling by energizing Y2, compressor contactor no. 2 (C2) is energized and compressor no. 2 starts. Heating, Units Without Economizer -- If Accessory or Optional Heater is Installed) Upon a call for heating through terminal W, IFC and heater contactor no. (HC) are energized. On units equipped for 2 stages of heat, when additional heat is needed, HC2 is energized through W2. APPLICATION DATA. DUCTWORK Ductwork should be attached to the curb on all units. Interior installation may proceed before unit is set in place on roof. If ductwork will be attached to the unit, do not drill in condensate drain pan area leaks may result. See figures below for information on field--installed concentric ductwork when applicable. 2. THRU -THE -CURB SERVICE CONNECTIONS Roof curb connections allow field power wires, control wires, and gas supply to enter through the roof curb opening. 3. THERMOSTAT - Use of 2--stage cooling thermostat is recommended for all units. A 2--stage cooling thermostat is required on units with accessory economizer to provide integrated cooling. 4. HEATING -TO -COOLING CHANGEOVER All units are automatic changeover from heating to cooling when automatic changeover thermostat and subbase are used.. AIRFLOW Units are draw--thru on cooling and blow--thru on heating. 6. MAXIMUM AIRFLOW - To minimize the possibility of condensate blow--off from evaporator, airflow through units should not exceed 00 cfm/nominal ton on size units. 7. MINIMUM AIRFLOW The minimum airflow for cooling is 300 cfm/nominal ton on size units. 8. MINIMUM AMBIENT COOLING OPERATION TEMPERATURE - Units are designed to operate at outdoor temperatures down to 40 F. To operate at lower outdoor--air temperatures, see Trade Prices or contact your local representative for appropriate accessory combinations for specific applications. 9. MAXIMUM OPERATING OUTDOOR -AIR TEMPERATURE -- For cooling, this temperature is 20 F for 80, 2 F for 240 size, and 2 F for 300 size. Refer to Cooling Capacities tables on pages 20 and 2 for further details. 0. INTERNAL UNIT DESIGN Due to the internal unit design (draw--thru over the motor), air path, and specially designed motors, the full horsepower (maximum continuous bhp) listed in the Physical Data table and the notes following each Fan Performance table can be utilized with extreme confidence. Using motors with the values listed in the Physical and Fan Performance Data tables will not result in nuisance tripping or premature motor failure. The unit warranty will not be affected. GUIDE SPECIFICATIONS: PAE CABINET: The cabinet shall be made of sturdy baked enamel coated galvanized steel. Base rails shall be 6 gauge steel and have fork lift slots and holes provided for lifting shackles. Unit shall be designed with convertible airflow and shipped ready for downflow applications with conversion to horizontal air flow accomplished by relocating two panels. Return air compartments shall be insulated with not less than /2 of water resistant coated glass fiber and not less than /2 of aluminum foil faced glass fiber in the furnace/supply compartments. COOLING SECTION: Units shall be factory charged and operationally ready. Each refrigeration circuit shall have a compressor, with internal overload protection, high and low pressure switches, filter drier and copper tube/aluminum fin evaporator and condenser coils. Units shall be capable of cooling operation down to 2ºF as shipped from the factory. COILS: The evaporator and condenser coils shall be fabricated with aluminum fins mechanically bonded to copper tubing. Both coils shall be pressure tested prior to assembly into the unit and electronically leak tested after assembly onto the unit. The evaporator coil shall be protected from dust and debris on the return air side by factory installed 2 air filters. CONDENSER FAN: The unit shall have a single direct drive propeller fan/motor assembly mounted directly to a vertical--discharge grille panel that is easily removable. Motors shall have permanently lubricated sleeve bearings and inherent overload protection. EVAPORATOR BLOWER: The units shall have a single belt driven evaporator blower. The motor shall have permanently lubricated ball bearings and internal overload protection. An adjustable motor drive sheave for matching air flow requirements shall be standard. Additionally high static accessory kits shall be available for air flows above the standard requirement. 20

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt)

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) PAH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP TONS (3 PHASE)

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP TONS (3 PHASE) PGS Product Specifications COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP -2 TONS ( PHASE) REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll

More information

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS/ELECTRIC UNIT R 22 SINGLE PACKAGE ROOFTOP TONS (3 Phase)

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS/ELECTRIC UNIT R 22 SINGLE PACKAGE ROOFTOP TONS (3 Phase) PGS Product Specifications COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS/ELECTRIC UNIT R 22 SINGLE PACKAGE ROOFTOP 6 12.5 TONS (3 Phase) REFRIGERATION CIRCUIT Scroll compressors on most models. High and low

More information

COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase)

COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase) PAE Product Specifications COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

PHB SERIES 7-1/2 and 10 TON

PHB SERIES 7-1/2 and 10 TON PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard

More information

RGMA Series Package Gas Electric SPECIFICATIONS

RGMA Series Package Gas Electric SPECIFICATIONS RGMA Series Package Gas Electric SPECIFICATIONS CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC COMMERCIAL GAS/ELECTRIC UNIT FEATURES EFFICIENCY 7-1/2 thru 20 ton Cooling, 200,000 thru 270,000 BTUH Heating SINGLE

More information

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions PHH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE HEAT PUMP UNITS R 22, SINGLE PACKAGE ROOFTOP, 3 15 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency heat

More information

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON 14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech

More information

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh PGF3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency Copeland scroll compressor, 4 & 5 ton have two--stage

More information

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP 400v- 3-50 Hz FOR EXPORT USE Combination heating and cooling, self-contained for year-round comfort. Systems install on rooftop

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only

More information

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No PGMD Series 10 SEER PACKAGE COOLING 1-1/2THRU5TONSINGLEPHASE CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained

More information

Model 558D/559F Sizes

Model 558D/559F Sizes Bryant Air Conditioning COMMERCIAL SINGLE-PACKAGE ROOFTOP ELECTRIC COOLING UNITS Model 558D/559F Sizes 036-300 3to25Tons Model 558D036-072 Model 559F180,216 Model 558D090-150 Model 559F240,300 DESCRIPTION

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration

More information

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGAA SERIES 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained for year-round comfort. Systems

More information

CAC SERIES 12-1/2 Thru 20 Ton

CAC SERIES 12-1/2 Thru 20 Ton CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer

More information

S/T Ratio. Input BTU/h

S/T Ratio. Input BTU/h SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

Product Data. Features/Benefits. 50TFQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons

Product Data. Features/Benefits. 50TFQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons Product Data 50TFQ004-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 3 to 10 Nominal Tons Single-package standard efficiency rooftop heat pumps with: State-of-the-art defrost system Dependable

More information

Product Data. Features/Benefits. 50TJQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons

Product Data. Features/Benefits. 50TJQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons Product Data 50TJQ004-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 3 to 10 Nominal Tons Single-package standard efficiency rooftop heat pumps with: State-of-the-art defrost system Dependable

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase COMMERCIAL SOUND REFRIGERANT ENVIRONMENTALLY PAD4 Product Specifications 14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/230 1 60 Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Product Data. Features/Benefits

Product Data. Features/Benefits Product Data 50TFF007-014 Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz Nominal Capacity: 17.6 kw to 35.9 kw (5 to 10.2 Tons) Single-Package Rooftop Units with: Galvanized

More information

Product Data. Features/Benefits. 50TFF Single-Package Rooftop Units Electric Cooling with Electric Heat Option. 3 to 12.

Product Data. Features/Benefits. 50TFF Single-Package Rooftop Units Electric Cooling with Electric Heat Option. 3 to 12. Product Data 50TFF004-014 Single-Package Rooftop Units Electric Cooling with Electric Heat Option 3 to 12.5 Nominal Tons Standard-Efficiency Rooftop Units with: Pre-painted galvanized steel cabinet for

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

Product Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 13 SEER Features/Benefits One-piece

More information

Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz, CE Units

Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz, CE Units Product Data 50TJ008-014 Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz, CE Units Nominal Capacity: 21.5 kw to 35.9 kw (6.1 to 10.2 Tons) Single-Package Rooftop Units with:

More information

14 SEER R -410A PACKAGE DUAL FUEL HEAT PUMP 2 to 5 TONS Two -Stage, Gas Heating / Electric Heating and Cooling Unit

14 SEER R -410A PACKAGE DUAL FUEL HEAT PUMP 2 to 5 TONS Two -Stage, Gas Heating / Electric Heating and Cooling Unit SOUND REFRIGERANT ENVIRONMENTALLY As an Energy Star Partner, International ComfortProducts hasdetermined thatthis product meets the ENERGY STAR guidelines for energy efficiency. PDX4 Product Specifications

More information

PGB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGB SERIES 3thru6-/3Ton SEER C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be

More information

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

Product Data. Features/Benefits

Product Data. Features/Benefits Product Data 50TFQ008-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 50 Hz Nominal Capacities: 26.4 to 35.2 kw (7 1 / 2 to 10 Nominal Tons) Single-package standard efficiency rooftop heat

More information

PGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT. PGF = Standard Models PGC = California Models with NOX baffles

PGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT. PGF = Standard Models PGC = California Models with NOX baffles PGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF = Standard Models PGC = California Models with NOX baffles C 1-1/2 THRU 5 TON, SINGLE PHASE Efficiency: PGF / PGC - 10 SEER. Combination

More information

Models 542J, 548F, 549B, 549C SINGLE PACKAGE ROOFTOP

Models 542J, 548F, 549B, 549C SINGLE PACKAGE ROOFTOP COMMERCIAL Models 542J, 548F, 549B, 549C SINGLE PACKAGE ROOFTOP Sizes 024-180 STANDARD AND HIGH EFFICIENCY DuraPac and DuraPac Plus HEAT PUMP UNITS 2 to 15 Tons 50-1219 548F036-072 549B036-072 50-1304

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS GR4GN Series Single Packaged Gas/Electric Units GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units The GR4GN is designed specifically for retrofit applications and compatibility

More information

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification

More information

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units TECHNICAL SPECIFICATIONS GP4SN Series Single Packaged Electric Cooling Units P4SN 10.3 EER Commercial System 7½ and 10 Ton Units These 7½ and 10 ton units are designed specifically for retrofit applications

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

Model 581B Sizes

Model 581B Sizes Bryant Air Conditioning COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEAT/ELECTRIC COOLING UNITS Model 581B Sizes 036-150 3to12 1 2Tons DESCRIPTION Unit 581B (Size 072 Shown) Unit 581B (Size 150 Shown) Specifically

More information

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GN Series Single Packaged Gas/Electric Units with R-410A R6GN 10.8 EER Commercial System 12½ and 15 Ton Units These units offer flexibility in the replacement market. The 12½

More information

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS 07---25 SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz Product Data 07-12 16-25 C10887 Carrier s versatile packaged heat pump air-handling units satisfy design requirements

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01 PAB SERIES 3thru6-1/3Ton Belt Drive CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT 10 SEER SINGLE PACKAGE Electric cooling, self contained for year-round comfort. Systems can be installed on roof top

More information

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP The new Goodman CPH Commercial Packaged Heat Pump features the environmentally friendly refrigerant R-410A, which is chlorine-free to help

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506 TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & 060 3, 4 & 5 NOMINAL TONS 10.0 SEER DESCRIPTION BCB Series heat pumps are convertible single package units with a common cabinet and a common

More information

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES 530.18-TGY (598) SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D3CE/D3CG10 & D4CE/D4CG090, 10 & 150 7-1/, 8-1/, 10 AND 1-1/ NOMINAL TONS 8.5-9.0 EER DCG MODEL SHOWN SUNLINE 000

More information

SINGLE PACKAGE ROOFTOP

SINGLE PACKAGE ROOFTOP COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS Model 580F The DuraPac Series Sizes 036-150 3 to 12 1 / 2 Tons 580F036-072 580F090-150 Standard-Efficiency Rooftop Units with: Exclusive

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

N4A4 C. Product Specifications

N4A4 C. Product Specifications COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier

More information

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207 TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 3, 4, 5 & 6 NOMINAL TONS 10.0 SEER (3, 4, & 5 Ton), 9.0 EER (6 Ton) DESCRIPTION YORK

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR:

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

Advance Product Data. Features/Benefits. 48HG HG Single Package Rooftop Units with ComfortLink Control / 2 to 25 Nominal Tons

Advance Product Data. Features/Benefits. 48HG HG Single Package Rooftop Units with ComfortLink Control / 2 to 25 Nominal Tons Advance Product Data 48HG014-028 50HG014-028 Single Package Rooftop Units with ComfortLink Control 12 1 / 2 to 25 Nominal Tons High Performance, Single Package Rooftop Units with: Cooling EERs up to 11.5

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower TECHNICAL SPECIFICATIONS R6GF Series Rev B Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower R6GF 15 SEER, 81% AFUE 2-5 Ton Units These single packaged gas/electric systems

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Three Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information