Product Data. that this product meets the S 95% AFUE S Two -stage operation

Size: px
Start display at page:

Download "Product Data. that this product meets the S 95% AFUE S Two -stage operation"

Transcription

1 DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling units Product Data S Stainless steel heat exchanger S Stainless steel secondary heat exchanger S High temperature limit control prevents overheating S Direct ignition with Silicon Nitride igniton S Flame roll-out sensors standard S External filter rack with permanent filters! WARNING S Dual Certified venting (1 or 2 pipe), Direct Vent Furnace S 4in (116mm) high with wider cabinets, for ease of installation S Factory shipped for natural gas, with Propane Gas conversion kits available S Four -way multipoise installation UNIT OPERATION HAZARD Failure to follow this warning could result in personal injury, death or property damage. S Vent pipe can be run horizontally or vertically This furnace is not designed for use in mobile homes, trailers, or recreational vehicles. S Internal condensate drain system SERVICE S Self diagnostics S Entire blower assembly removable COMFORT S Adjustable timed blower heating Off ama S Adjustable timed blower cooling On/Off S Thermal lined, one piece steel cabinet for noise reduction S Insulated blower compartment S 24 and 115VAC humidifier terminals As an ENERGY STAR S Electronic air cleaner terminal Partner, Bryant Heating S Dehumidification option & Cooling has determined EFFICIENCY that this product meets the S 95% AFUE S Two -stage operation ENERGY STAR guidelines for energy efficiency. S ECM Variable speed DC motor S Two -stage Induced draft blower S In -shot burners CERTIFIED S California NOx approved QUALITY UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Model Dimensions H x W x D Input Efficiency Cooling Capacity Weight Number Inches Millimeters (MBTUH) Lbs Kg x 19 1 / 8 x x 486 x TON x 19 1 / 8 x x 486 x TON x 22 3 / 4 x x 578 x TON x 24 1 / 2 x x 522 x TON C E D E S R T I G N I F I E D 1

2 FURNACE SPECIFICATIONS Model Number { INPUT HIGH HEAT(BTUH) LOW HEAT (BTUH) 4, 28, 6, 42, 8, 56, 1, 7, { HTG. CAPACITY HIGH HEAT(BTUH) LOW HEAT (BTUH) TEMP. RISE RANGE HIGH HEAT ( o F/ o C) LOW HEAT( o F/ o C) 38, 27, 25-55/ / , 41, 3-6/ / , 54, 3-6/ / , 67, 3-6/ /17-33 VENT SIZE^ in(mm) 2 (51) OD 2-3 (51-76) OD 3 (76) OD 3 (76) OD VOLTS/HZ/PH 115/6/1 115/6/1 115/6/1 115/6/1 RATING PLATE AMPS MIN./MAX. VOLTAGE 14/127 14/127 14/127 14/127 TRANSFORMER (V.A.) GAS PIPE SIZE - inches(mm) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) COOLING CAP. (TONS) HIGH ALTITUDE PRESSURE SWITCH FILTER SIZE - inches(mm) (qty) DIMENSIONS - WxDxH inches(mm) 16X25X1 (46x635x25) (1) 19 1 / 8 x29x4 (486x737x116) 16X25X1 (46x635x25) (1) 19 1 / 8 x29x4 (486x737x116) 16X25X1 (46x635x25) (2) 22 3 / 4 x29x4 (486x737x116) 16X25X1 (46x635x25) (2) 24 1 / 2 x29x4 (622x737x116) WEIGHT - Lbs(kg) 15 (68) 168 (76) 187 (85) 23 (92) ^ Vent size may vary depending on length, number of elbows, standard vent or direct vent. See Installation Instructions. { Gas input ratings are certified for elevations to 2 ft. (61 M). In USA for elevations above 2 ft. (61 M), ratings must be derated 2% (natural gas) or 4% (propane gas) for each ft. (35 M) above sea level. In Canada for altitudes of 2 ft. (61 M) to 45 ft. (1372 M) ratings must be derated 5% (natural gas) and 1% (propane gas). Cabinet to Combustible Clearances - in(mm) TOP BOT RH LH BACK FRNT FLUE 1 (25.4) 3(76.2) 2 1 / 4 (57.2) 13 1 / 4 (336.6) C D TOP GAS VENT F E 7 (177.8) G AIR INTAKE VENT LEFT SIDE 6 11 / 16 ELECTRICAL (177.5) 1 / 4 TRAP (KO) (COUNTERFLOW) (318) AIR INTAKE (KO) (ALTERNATE) 4 13 / 16 TRAP (KO) (122.2) UPFLOW/HORIZONTAL THERMOSTAT (KO) 21 5 / (549.3) / 8 (47.6 ) 24 (69.6) BOTTOM 4 7 / 8 (123.8) 23 1 / / 8 (587.4) (98.4) H 1 / (27) / 16 (347.7) / 16 (34.9) (84.9) 1 3 / (758.8) / / 4 (73.3) 24 1 / (611.2) / /16 (439.7) 1 11 (53.2) / 16 (42.9) A B FRONT KO = KnockOut ALL DIMENSIONS: in (mm) MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR ALL UNITS - in (mm) REAR FRONT (combustion air openings in 3 (76.2) furnace and in structure) Required For Service *24 (69.6) ALL SIDES Of SUPPLY PLENUM 1 (25.4) SIDES VENT TOP OF FURNACE 1 (25.4) *3 (762mm) clearance recommended for furnace removal. Horizontal position: Line contact is permissible only between lines formed by intersections of top and two sides of furnace jacket, and building joists, studs or framing. 1 / 4 (31.7) 2 7 / 8 (73) 4 5 / (19.5) / 8 (6.3 ) 1 / (27) 16 GAS (KO) NOTE: Evaporator A coil drain pan dimensions may vary from furnace duct opening size. Always consult evaporator specifications for duct size requirements. Furnace is designed for bottom return or side return. Return air through back of furnace is NOT allowed / 2 (723.9) 18 1 (19.1) / 2 (469.9) 3 / 4 TYPE RIGHT SIDE TRAP (KO) (COUNTERFLOW) ELECTRICAL (KO) AIR INTAKE (KO) (ALTERNATE) 1 3 / 4 13 / (3.2) (122.2) VENT (KO) TRAP (KO) 1 / 16 UPFLOW/HORIZONTAL 29 7 / 8 (27) (758.8) 7 21 / 27 3 / 4 16 (69.6) 21 5 (177.8) (57.2) / 8 THERMOSTAT 9 13 / 16 (549.3) (249.2) 17 5 / 13 1 / / 16 (439.7) (336.6) (855.7) 1 11 / 16 (KO) (42.9) 4 (116) 47 / 215 / 8 8 (123.8) (549.3) 17 / 8 24 (47.6) (69.6) A9241 2

3 ACCESSORIES Model Number Description Used With Models KGANP4712HW Gas Conversion Kits - Natural gas to propane conversion Kit. Allows field conversion to propane gas. KGAPN412HW Gas Conversion Kits - Propane to natural gas conversion kit. Allows field conversion to natural gas. KGAFR91P16 Filter Kits - External filter frame. 16 x25 (46 x 635 mm) KGAFR11P2 Filter Kits - External filter frame. 2 x 25 (58 x 635 mm) P Condensate neutralizer kit - for condensing gas furnaces All if required KGAVT81CVT KGAVT71CVT 3 (76 mm) Concentric vent kit - allows single wall penetration for 2 pipe direct vent applications (9+). 2 (51 mm) Concentric vent kit - allows single wall penetration for 2 pipe direct vent applications (9+) KGAHA611PSW High Altitude Pressure Switch Kit 364 KGAHA621PSW High Altitude Pressure Switch Kit 366, KGAHA631PSW High Altitude Pressure Switch Kit 8 KGAHA641PSW High Altitude Pressure Switch Kit 61 KGASB31P1 KGASB41P2 Combustible Floor Base without cased coil used KGASB81P6 KGASB51P3 KGASB61P4 Combustible Floor Base with cased coil used KGASB71P5 KGADA11PYN Downflow Coil Adapter Size Size Size Size Size Size 46 Orifice Kit (Qty. 5) Size Size Size Size Size Size 56 + Must be ordered from Service Parts 3

4 Circulation Air Blower Data Cooling Adjustment High in wc(125 Pa) Low Cool (8% of High Cool) ** Adjust Jumper Setting 5&6 L/s L/s 3&4 Heating Adjustment High Heat in wc (5 Pa) Low Heat Change at Resultant Static * *NOM * NOM NOM NOM Airflow performance includes 1 washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 1% reduction in airflow when in Comfort position and a call for low or high cooling is present with the O line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 2% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings. Table 2 Airflow Table 3 SW2 DIP Assignments Continuous in wc (25 Pa) ESP 1&2 L/s * Table 4 DIP SW2-7/8 Timed ON (sec) Blower Parameter 1&2 Cont Fan Adj 3&4 Heat Speed Adj 5&6 Cool Speed Adj 7&8 Cool On/Off Delay Cooling Delay Options (SW2-7, 8) ON DELAY OFF DELAY Airflow during on Timer OFF (sec) Airflow during off * 5 OFF 9 1% 1 5 OFF OFF 1 3 5% 3 1% % 18 5% Airflow % is of High Cool airflow demand determined from SW2--5/6 Table 1 Airflow resumes to 1% after on time is completed Airflow stops (or switches to continuous fan speed) after off time is completed MAX s for Factory Washable Filters Filter Size (in/mm) L/s 14 X25 / 356 x X25 / 46 x X25 / 58 x X25 / 61 x Max based on FPM (3. M/s) NOTE: Disposable filters are typically rated at 3 FPM (1.5 m/s). These filters only allow half the airflow when compared to FPM (3. M/s) filters. EXAMPLE (approx.): 2in X FPM = 3 FPM = 58mm x 3. M/s = M/s = 472 L/s 4

5 Circulation Air Blower Data Cooling Airflow Settings High Cool Airflow 14 + NOM NOM NOM NOM Low Cool Airflow + NOM NOM NOM NOM ESP ( inches of wc) 5

6 Circulation Air Blower Data Cooling Adjustment High in wc(125 Pa) Low Cool (8% of High Cool) ** Adjust Jumper Setting 5&6 L/s L/s 3&4 Heating Adjustment High Heat in wc (5 Pa) Low Heat Change at Resultant Static * *NOM * NOM NOM NOM Airflow performance includes 1 washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 1% reduction in airflow when in Comfort position and a call for low or high cooling is present with the O line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 2% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings. Table 2 Airflow Table 3 SW2 DIP Assignments Continuous in wc (25 Pa) ESP 1&2 L/s * Table 4 DIP SW2-7/8 Timed ON (sec) Blower Parameter 1&2 Cont Fan Adj 3&4 Heat Speed Adj 5&6 Cool Speed Adj 7&8 Cool On/Off Delay Cooling Delay Options (SW2-7, 8) ON DELAY OFF DELAY Airflow during on Timer OFF (sec) Airflow during off * 5 OFF 9 1% 1 5 OFF OFF 1 3 5% 3 1% % 18 5% Airflow % is of High Cool airflow demand determined from SW2--5/6 Table 1 Airflow resumes to 1% after on time is completed Airflow stops (or switches to continuous fan speed) after off time is completed MAX s for Factory Washable Filters Filter Size (in/mm) L/s 14 X25 / 356 x X25 / 46 x X25 / 58 x X25 / 61 x Max based on FPM (3. M/s) NOTE: Disposable filters are typically rated at 3 FPM (1.5 m/s). These filters only allow half the airflow when compared to FPM (3. M/s) filters. EXAMPLE (approx.): 2in X FPM = 3 FPM = 58mm x 3. M/s = M/s = 472 L/s 6

7 Circulation Air Blower Data Cooling Airflow Settings High Cool Airflow chart + NOM NOM NOM NOM Low Cool Airflow chart + NOM NOM NOM NOM

8 Circulation Air Blower Data - 8 Cooling Adjustment High in wc(125 Pa) Low Cool (8% of High Cool) ** Adjust Jumper Setting 5&6 L/s L/s 3&4 Heating Adjustment High Heat in wc (5 Pa) Low Heat Change at Resultant Static * *NOM * NOM NOM NOM Airflow performance includes 1 washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 1% reduction in airflow when in Comfort position and a call for low or high cooling is present with the O line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 2% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings. Table 2 Airflow Table 3 SW2 DIP Assignments Continuous in wc (25 Pa) ESP 1&2 L/s * Table 4 DIP SW2-7/8 Timed ON (sec) Blower Parameter 1&2 Cont Fan Adj 3&4 Heat Speed Adj 5&6 Cool Speed Adj 7&8 Cool On/Off Delay Cooling Delay Options (SW2-7, 8) ON DELAY OFF DELAY Airflow during on Timer OFF (sec) Airflow during off * 5 OFF 9 1% 1 5 OFF OFF 1 3 5% 3 1% % 18 5% Airflow % is of High Cool airflow demand determined from SW2--5/6 Table 1 Airflow resumes to 1% after on time is completed Airflow stops (or switches to continuous fan speed) after off time is completed MAX s for Factory Washable Filters Filter Size (in/mm) L/s 14 X25 / 356 x X25 / 46 x X25 / 58 x X25 / 61 x Max based on FPM (3. M/s) NOTE: Disposable filters are typically rated at 3 FPM (1.5 m/s). These filters only allow half the airflow when compared to FPM (3. M/s) filters. EXAMPLE (approx.): 2in X FPM = 3 FPM = 58mm x 3. M/s = M/s = 472 L/s 8

9 Circulation Air Blower Data - 8 Cooling Airflow Settings High Cool Airflows NOM NOM NOM NOM Low Cool Airflow NOM NOM NOM NOM

10 Circulation Air Blower Data - 61 Cooling Adjustment High in wc(125 Pa) Low Cool (8% of High Cool) ** Adjust Jumper Setting 5&6 L/s L/s 3&4 Heating Adjustment High Heat in wc (5 Pa) Low Heat Change at Resultant Static * *NOM * NOM NOM NOM Airflow performance includes 1 washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 1% reduction in airflow when in Comfort position and a call for low or high cooling is present with the O line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 2% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings. Table 2 Airflow Table 3 SW2 DIP Assignments Continuous in wc (25 Pa) ESP 1&2 L/s * Table 4 DIP SW2-7/8 Timed ON (sec) Blower Parameter 1&2 Cont Fan Adj 3&4 Heat Speed Adj 5&6 Cool Speed Adj 7&8 Cool On/Off Delay Cooling Delay Options (SW2-7, 8) ON DELAY OFF DELAY Airflow during on Timer OFF (sec) Airflow during off * 5 OFF 9 1% 1 5 OFF OFF 1 3 5% 3 1% % 18 5% Airflow % is of High Cool airflow demand determined from SW2--5/6 Table 1 Airflow resumes to 1% after on time is completed Airflow stops (or switches to continuous fan speed) after off time is completed MAX s for Factory Washable Filters Filter Size (in/mm) L/s 14 X25 / 356 x X25 / 46 x X25 / 58 x X25 / 61 x Max based on FPM (3. M/s) NOTE: Disposable filters are typically rated at 3 FPM (1.5 m/s). These filters only allow half the airflow when compared to FPM (3. M/s) filters. EXAMPLE (approx.): 2in X FPM = 3 FPM = 58mm x 3. M/s = M/s = 472 L/s 1

11 Circulation Air Blower Data - 61 Cooling Airflow Settings High Cooling Airflows (+) (NOM) (-) 1(+) 1(NOM) 1(-) 1(+) 1(NOM) 1(-) 11(+) 11(NOM) 11(-) Low Cool Airflow NOM NOM NOM NOM

12 ON = OFF = Variable Speed Tap Select Interface Board (TSIB) A9242 E29 Bryant Heating & Cooling Systems D 731 W. Morris St. D Indianapolis, IN Printed in U.S.A. Edition Date: 4/9 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. PDS--- 1 Replaces: NEW 12

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) C9MVX SoftSound VS90 Product Specifications 95% Variable Speed Two Stage Heating Furnace FLEXIBILITY Supports two stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40in (1016mm)

More information

N9MPD Product Specifications

N9MPD Product Specifications Single Stage Furnace Multiposition FLEXIBILITY Dual certified venting (1 or 2 pipes) Direct Vent furnace 40 (1016mm) high with wider cabinets, for ease of installation Factory shipped as natural gas, with

More information

G8MVL. Product Specifications

G8MVL. Product Specifications 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

TSTAT0101SC Recommended (sold separately)

TSTAT0101SC Recommended (sold separately) Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

F8MTL. Product Specifications

F8MTL. Product Specifications 80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

FG7T (E and N Series)

FG7T (E and N Series) TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different

More information

FG7S (C and L Series)

FG7S (C and L Series) TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization

More information

WFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. F verification of certification f individual products, go to www.ahridirecty.g.

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

Multi-Position, Multi-Speed Gas Furnaces

Multi-Position, Multi-Speed Gas Furnaces Heating Input: 40,000 140,000 BTU/h / Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve control technology allows installer to

More information

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev. TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized

More information

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless

More information

UPFLOW/ HORIZONTAL GAS FURNACE

UPFLOW/ HORIZONTAL GAS FURNACE FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 92% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE / SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel

More information

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FG7T (A and K Series), Smartlite Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE

More information

AF90. AF90 Gas Furnace High Efficiency. Features

AF90.   AF90 Gas Furnace High Efficiency. Features AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty

More information

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE / 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING 92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped

More information

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 96G1E-100 (04/2018) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h / Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FGT (A and K Series) Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The high efficiency

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h // Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 100,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8

More information

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace Gas Furnaces Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace U802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE / Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 7 Wiring Diagram... 10 Accessories... 11 Minimum Filter

More information

GKS9 Series. Upflow Multi-Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h

GKS9 Series. Upflow Multi-Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h Series Upflow Multi-Position, Multi-Speed Gas Furnace up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Standard Features Heavy-duty aluminized-steel, dual-diameter, tubular heat exchanger Stainless-steel

More information

93% Gas Furnaces Single Stage

93% Gas Furnaces Single Stage Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 93% Gas Furnaces Single Stage Form No. AA931A-100 (05/2012) HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped

More information

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) FORM NO. G66-544 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. ) FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and

More information

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VA, TDHMB060BCV3VA TUHMB080ACV3VA, TDHMB080ACV3VA

More information

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h / ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11

More information

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h Heating Input: 40,000 140,000 BTU/h /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic

More information

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace RGPT- Series 80% A.F.U.E. Input Rates 50-125 kbtu ENER UIDE Annual Fuel Utilization Efficiency

More information

Upflow, Upflow / Horizontal, Counterflow / Horizontal

Upflow, Upflow / Horizontal, Counterflow / Horizontal Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long

More information

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity

More information

GKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h

GKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h Series up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Upflow Multi- Position, Multi-Speed Gas Furnace Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

Upflow, Upflow / Horizontal, Counterflow

Upflow, Upflow / Horizontal, Counterflow , / Horizontal, 90/92 Gas Furnace CG90/92 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long life AL29-4C Stainless

More information

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor 80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor A80-1E Form No. A80-1E-100 (10/2011) Features and Benefits CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped

More information

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN A951E PRODUCT SPECIFICATIONS SINGLE STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A951E-100 (10/2018) CONTROLS Single stage gas valve Durable silicon nitride ignitor Self diagnostics saves

More information

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces Heating Input: 40,000 140,000 TU/h //GHS8 Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas valve Norton hot

More information

AKSS92. Single-Stage. Heating Input: 46, ,000 BTU/h. up to 92.1% AFUE

AKSS92. Single-Stage. Heating Input: 46, ,000 BTU/h. up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Single-Stage Multi-Speed Gas Furnace up to 92.1% AFUE Standard Features Stainless-steel secondary heat exchanger Single-stage gas valve Durable Silicon Carbide ignitor

More information

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS 80% Gas Furnace Single Stage - High Efficiency (Constant Torque) Motor 80G1-E Features and Benefits Form No. R80G1-E-100 (11/2011) CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped

More information

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 45,000 1,000 BTUH The GMS8/GDS8/GHS8 single-stage, multi-speed gas furnaces offer installation versatility.

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

Rheem Classic Series Downflow Gas Furnace

Rheem Classic Series Downflow Gas Furnace Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing

More information

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE FORM NO. G22-448 REV. 10 Supersedes Form No. G22-448 Rev. 9 GAS FURNACES UGPH- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces THIS MODEL 78% 82% 88% 92.0% 97% Air Gas Furnaces Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces RGPQ- Series 80% A.F.U.E. Models with Input Rates from 45-105 kbtu (U.S. & Canadian Models)

More information

KG7S (A and K Series)

KG7S (A and K Series) TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed

More information

A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN

A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE FORM NO. A802V-100 (04/2016) VENTING Rotatable draft inducer for venting flexibility INSTALLATION FEATURES Left and right utility connections