Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig.3 Slip-InDamper. Fig.1 RoundDamper

Size: px
Start display at page:

Download "Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig.3 Slip-InDamper. Fig.1 RoundDamper"

Transcription

1 CLS COM OPN CLS COM OPN CLS COM OPN ZONE ERS Product Data IRFLOW IRFLOW Fig.3 Slip-InDamper Fig.1 RoundDamper FETURES/ENEFITS Carrier zone dampers are the latest in design and were developed to fit field requirements for a variety of ductwork shapes and sizes. These dampers use 24vac, direct -drive actuators for smooth, quiet performance. novel shaft design provides both automatic alignment of the damper with the shaft and a position indicator. spring -loaded disengagement button to momentarily release main gear and damper blade allows for manual positioning of installed dampers. Recessed electrical connections provide protection, as well as visibility and easy access for wiring without removing a cover. Permanently -lubricated bushings, with a split-shaft design for round and rectangular style dampers, align the damper blade to the shaft for efficient reliable service. The actuator is smaller and round dampers are shorter to better fit in tight locations Fig. 2 Rectangular Damper 1

2 MODEL NUMER NOMENCLTURE SLS 08x10 Damper Length x Width, Diameter - INC for Round Slip-In Side Mount (SLS) Slip-In ottom Mount (SL) Round (RND) Rectangular (REC) arometric (R) 2

3 OPEN CLOSED DIMENSIONS IR DUCT SIDE RIL LISTED ER HEIGHT QUICK LDE RELESE UTTON (RED) SIDE RIL Fig. 4 Side-Mount Configuration SIDE RIL SIDE RIL IR DUCT OPEN CLOSED LISTED ER WIDTH 1 QUICK LDE RELESE UTTON (RED) See dimensions on next page. Fig. 5 ottom -Mount Configuration

4 DIMENSIONS CONTINUED SLIP -IN ER DIMENSIONS (IN.) Catalog number Description SLS08X08--- SIDE MOUNT 8X8 7 13/ /16 SL08X08--- OTTOM MOUNT 8X8 7 13/ /16 SLS08X10--- SIDE MOUNT 8X10 97/8 7 13/16 SL08X10--- OTTOM MOUNT 8X /16 97/8 SLS08X12--- SIDE MOUNT 8X /8 7 13/16 SL08X12--- OTTOM MOUNT 8X / /8 SLS08X14--- SIDE MOUNT 8X /8 7 13/16 SL08X14--- OTTOM MOUNT 8X / /8 SLS08X16--- SIDE MOUNT 8X /8 7 13/16 SL08X16--- OTTOM MOUNT 8X / /8 SLS08X18--- SIDE MOUNT 8X /8 7 13/16 SL08X18--- OTTOM MOUNT 8X / /8 SLS08X20--- SIDE MOUNT 8X / /8 SL08X20--- OTTOM MOUNT 8X /8 7 13/16 SLS08X22--- SIDE MOUNT 8X / /8 SL08X22--- OTTOM MOUNT 8X /8 7 13/16 SLS08X24--- SIDE MOUNT 8X / /8 SL08X24--- OTTOM MOUNT 8X /8 7 13/16 SLS10X10--- SIDE MOUNT 10X10 97/8 9 13/16 SL10X10--- OTTOM MOUNT 10X /16 97/8 SLS10X12--- SIDE MOUNT 10X /8 9 13/16 SL10X12--- OTTOM MOUNT 10X / /8 SLS10X14--- SIDE MOUNT 10X /8 9 13/16 SL10X14--- OTTOM MOUNT 10X / /8 SLS10X16--- SIDE MOUNT 10X /8 9 13/16 SL10X16--- OTTOM MOUNT 10X / /8 SLS10X18--- SIDE MOUNT 10X /8 9 13/16 SL10X18--- OTTOM MOUNT 10X / /8 SLS10X20--- SIDE MOUNT 10X /8 9 13/16 SL10X20--- OTTOM MOUNT 10X / /8 SLS10X22--- SIDE MOUNT 10X /8 9 13/16 SL10X22--- OTTOM MOUNT 10X / /8 SLS10X24--- SIDE MOUNT 10X /8 9 13/16 SL10X24--- OTTOM MOUNT 10X / /8 SLS12X12--- SIDE MOUNT 12X / /16 SL12X12--- OTTOM MOUNT 12X / /8 SLS12X14--- SIDE MOUNT 12X / /16 SL12X14--- OTTOM MOUNT 12X / /8 SLS12X16--- SIDE MOUNT 12X / /16 SL12X16--- OTTOM MOUNT 12X / /8 SLS12X18--- SIDE MOUNT 12X / /16 SL12X18--- OTTOM MOUNT 12X /16 77/8 SLS12X20--- SIDE MOUNT 12X / /16 SL12X20--- OTTOM MOUNT 12X / /8 SLS14X14--- SIDE MOUNT 14X / /16 SL14X14--- OTTOM MOUNT 14X / /8 SLS14X16--- SIDE MOUNT 14X / /16 SL14X16--- OTTOM MOUNT 14X / /8 SLS14X20--- SIDE MOUNT 14X / /16 SL14X20--- OTTOM MOUNT 14X / /8 SLS16X16--- SIDE MOUNT 16X / /16 SL16X16--- OTTOM MOUNT 16X / /8 SL16X20--- OTTOM MOUNT 16X / /16 4

5 DIMENSIONS CONTINUED C 2 3/4" OPEN CLOSED 2 1/4" 4 1/4" ROUND ER DIMENSIONS (IN.) PRT NO. C RND06INC /4 RND08INC /4 RND10INC /4 RND12INC /4 RND14INC /4 RND16INC /4 5

6 DIMENSIONS CONTINUED C D OPEN CLOSED E 7 4 1/2" 2 3/4" 2 1/4" PLCES RECTNGULR ER DIMENSIONS (IN.) PRT NO. C D E REC08x /4 13-1/2 12-1/4 REC08x /4 13-1/2 12-1/4 REC08x /4 13-1/2 12-1/4 REC08x /4 13-1/2 12-1/4 REC10x /4 15-1/2 14-1/4 REC10x /4 15-1/2 14-1/4 REC10x /4 15-1/2 14-1/4 REC10x /4 15-1/2 14-1/4 6

7 DIMENSIONS CONTINUED 2 5/ 8" D 1" 1/ 2" 1 5/ 8" 10 1/ 8" C 4 1/ 4" 6" 1/ 2" 4 PLCES RECTNGULR ROMETRIC -YPSS ER DIMENSIONS (IN.) PRT NO. C D MX IRFLOW R08x /4 13-1/ CFM R08x / CFM D SHFT E LDE WEIGHT RM C WEIGHT ROUND ROMETRIC -YPSS ER DIMENSIONS (IN.) PRT NO. C D E NUMER OF WEIGHTS MX IRFLOW R08INC /16 1-1/ R10INC /8 9-15/16 1-1/ R12INC / /16 1-1/ R14INC / /16 1-1/ R16INC / /16 1-1/

8 PHYSICL DT Input Voltage 24vac Nominal Input Power 2va Damper Output Torque 10 in. - Lb. mbient Temperatures 0 F to 158 F or 18 C to70 C Wire Connections Common, Open, Close Wire Connectors Plated Screw Terminals For WG Stroke Time ngular Rotation per Sec CT45DEG 3 per Sec CT90DEG 6 per Sec Travel Time 15 Sec arometric ypass Pressure Range in. wc 8

9 ER PRESSURE DROP IRFLOW DT ER 400 FPM 600 FPM 800 FPM DESIGN UNIT MXIMUM In. In. In. (CFM) (CFM) SLS08X SL08X SLS08X SL08X SLS08X SL08X SLS08X SL08X SLS08X SL08X SLS08X SL08X SLS08X SL08X SLS08X SL08X SLS08X SL08X SLS10X SL10X SLS10X SL10X SLS10X SL10X SLS10X SL10X SLS10X SL10X SLS10X SL10X SLS10X SL10X SLS10X SL10X SLS12X SL12X SLS12X SL12X SLS12X SL12X SLS12X SL12X SLS12X SL12X SLS14X SL14X SLS14X SL14X SLS14X SL14X SLS16X SL16X SL16X RND06INC RND08INC RND10INC RND12INC RND14INC RND16INC REC08X REC08X REC08X REC08X REC10X REC10X REC10X REC10X NOTE: s the design airflow for dampers is exceeded, the potential for airflow noise problems increases. HOW TO USE PRESSURE DROP DT 1. Calculate airflow for each zone based on load and number of zones. 2. s duct system is designed, calculate pressure losses in each duct run and in the air handler (filter and cooling coil). 3. ased on the duct size and amount of airflow required in each zone, calculate a duct velocity for the air through the damper. 4. Use the chart to find the pressure drop for the damper and the calculated velocity in each duct run. 5. Put the damper pressure drop data into the duct losses for each run and calculate a total system pressure loss. 6. Make sure that the unit specified for the application will supply the required amount of air for the calculated system pressure loss. 7. Make sure that the maximum airflow for each damper is not exceeded. Example: ssume an installation requires a maximum airflow of 600 CFM per zone. If 8 -in. X 18 -in. ducts are used in the house the duct area is 8 -in. X 18-in. /(144 sq in. per sq ft) gives 1.0 sq ft of duct area. Dividing the airflow for each zone (600 CFM) by the duct area (1.0 sq ft) gives 600 fpm. REC08X18: in. SLS08X18: in. SL08x18: in. 9

10 SERVICE TRINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence large selection of product, theory, and skills programs is available, using popular video-based formats and materials. ll include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CLL FOR FREE CTLOG [ ] Packaged Service Training [ ] Classroom Service Training Copyright 2005 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN Printed in U.S.. Edition Date: 11/05 Catalog No: --- 4PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: ---3PD 10

Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig. 3 - Slip -In Damper. Fig. 1 - Round Damper

Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig. 3 - Slip -In Damper. Fig. 1 - Round Damper CLS COM OPN CLS COM OPN ZONE ERS Product Data IRFLOW IRFLOW Fig. 3 - Slip -In Damper 05253 Fig. 1 - Round Damper 05251 FETURES/ENEFITS CLS COM OPN Carrier zone dampers are the latest in design and were

More information

Product Data. Residential Zone Dampers FEATURES/BENEFITS

Product Data. Residential Zone Dampers FEATURES/BENEFITS Product Data Residential Zone Dampers FETURES/ENEFITS IRFLOW CLS COM OPN IRFLOW 90 0 45 ROUND DMPER CLS COM OPN 90 0 45 RECTNGULR DMPER Carrier residential zone dampers are the latest in design and were

More information

ZONE DAMPERS. Form No. PDS DAMP.0.3

ZONE DAMPERS. Form No. PDS DAMP.0.3 90 ZONE DMPERS IRFLOW IRFLOW 90 45 0 CLS COM OPN ROUND DMPER FETURES/ENEFITS ryant zone dampers are the latest in design and were developed to fit field requirements for a variety of duct work shapes and

More information

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a

More information

Installation Instructions

Installation Instructions Installation Instructions Downflow Conversion Kit KFADC NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS

More information

SD-1250 and SD-1600 Series Smoke Dampers

SD-1250 and SD-1600 Series Smoke Dampers SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke

More information

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System Product Data ZONEKIT4ZCAR Comfort Zone Residential Zoning System Comfort Zone is a residential 4-zone system integrated for home comfort. The Comfort Zone kit includes the Comfort Zone Center, 4-zone controller,

More information

Installation and Start-Up Instructions

Installation and Start-Up Instructions Visit www.carrier.com SYSTXCC4ZC01 Infinity Control Installation and Start-Up Instructions Infinity Control SYSTXCC4ZC01 A97040 NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Instructions

Installation Instructions Motor Master ontrol Kit ancels: IIK 561A-18-1 IIK 561-18-1 11-95 Installation Instructions Part No. 32LT660004 and 005 This symbol indicates a change since last issue. INTRODUTION These instructions cover

More information

Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL

Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL SYSTXCCUIZ01-- V Infinityt Zone Control Product Data A07258 NOTE: Infinityt Zone Control compatible with Infinity rated indoor equipment only. INFINITY t ZONE CONTROL Carrierr specializes in creating a

More information

Installation and Start Up Instructions

Installation and Start Up Instructions SYSTXCC4ZC01 Infinityr Control Installation and Start Up Instructions A97040 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment,

More information

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

Air Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation

Air Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation ir Flow Factors Model: TDC irflow Measurements Procedure 1. Record diffuser velocities with lnor probe in the locations and orientation shown the velocity Measurement Location Chart. Note: Each diagram

More information

PIM Pressure Independence Module

PIM Pressure Independence Module PIM Pressure Independence Module PIM : Product Overview BENEFITS AT A GLANCE QUIET VAV DIFFUSER OPERATION The PIM Pressure Independence Module is a modulating static pressure controller/actuator that allows

More information

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD60, FSD60LP CoMINAtIoN FIRe AND SMoKe DAMPeR 1 1 /2 HoUR UL555 RAteD, UL555S LeAKAge CLASS 1 APPLICAtIoN Ruskin FSD60 Series

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers

More information

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD60, FSD60LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 1 PPLICTION Ruskin FSD60 Series ultra

More information

RPD ROUND PLAQUE DIFFUSER

RPD ROUND PLAQUE DIFFUSER ROUND PLAQUE DIFFUSER s (RPD) provide a balance between engineering and architectural needs, with a flush appearance and superior VAV performance in both ceiling and exposed duct mounting applications.

More information

CCS Zone/Bypass Damper Assembly

CCS Zone/Bypass Damper Assembly Code No. LIT-1900539 Issued July 15, 2011 UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x CCS Zone/Bypass Damper Assembly Description The Commercial Comfort System (CCS) Zone/Bypass Damper are zone control

More information

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES 30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS INSTALLATION OPERATION & MAINTENANCE New Release Form 130.13-NOM4 (908) In conjunction with the use of these instructions, obtain and refer to the construction,

More information

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest Product Data FA4A FB4A Direct Expansion Fan Coil Sizes 08 thru 070 Air Handling Technology At Its Finest Carrier s FA4A, FB4A, and direct expansion multipoise fan coils are designed to cover a wide range

More information

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD36, FSD36LP COMINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 APPLICATION Ruskin FSD36 Series

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of

More information

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS BY JOHNSON CONTROLS INSTALLATION OPERATION & MAINTENANCE MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS New Release Form ET130.13-NOM4 (908) In conjunction with the use of these instructions, obtain

More information

FOR USE IN SOLUTION AIR HANDLING UNITS

FOR USE IN SOLUTION AIR HANDLING UNITS AMS-60 AIRFLOW MONITORING DEVICE APPLICATION GUIDE Supersedes: NOTHING Form 102.20-AG1 (303) FOR USE IN SOLUTION AIR HANDLING UNITS GENERAL The YORK AMS-60 is an airflow monitoring device which combines

More information

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION DRUM LOUVERS 45DL SERIES HIH CAPACITY LON THROW ALUMINUM CONSTRUCTION Models: Single Vanes 45DL2 Split Vanes Suffix '-O' adds a steel opposed blade damper Models -O and 45DL2 Model Series 45DL Drum Louvers

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION FIERGLSS ROUND CONTROL S INTRODUCTION The M.K. Plastics series K-RD are manufactured to meet the needs of the odor control and corrosive HVC industries by providing a corrosion-resistant FRP Damper that

More information

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions SYST0101ZP Ion Control Installation and Start---Up Instructions A97040I NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment,

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -HS, Vektor -MS and Vektor -CS with Variable Geometry Nozzle September 017 Vektor -HS, Vektor -MS and Vektor -CS Greenheck s Variable Geometry Nozzle exhaust systems allow

More information

ATP-2040 Electric Damper Actuator/Transmitter

ATP-2040 Electric Damper Actuator/Transmitter ATP-2040 Electric Damper Actuator/Transmitter Kit Includes 1. Actuator/Transmitter package: factory assembled Actuator (EDA-2040) and Transmitter (DPT-2000). Product Code Number Coupler Size Differential

More information

Owner s Information Manual

Owner s Information Manual 50ES---A and 50VL---C Comfort 13SEERThreePhase2½---5NominalTons (Sizes 30---60) Comfort 14 SEER Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Single Packaged Air Conditioner System With Puronr

More information

Demand Based Static Pressure Reset Control for Laboratories

Demand Based Static Pressure Reset Control for Laboratories Accutrol, LLC Product Sheet Demand Based Static Pressure Reset Control for Laboratories Accutrol, LLC 21 Commerce Drive, Danbury, CT 06810 203-445-9991 www.accutrolllc.com Contents and specifications are

More information

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm Product Data 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems 40 to 3700 cfm The 35J retrofit terminal units offer: Unit casing of 22-gage galvanized steel construction (optional

More information

Installation Instructions

Installation Instructions 010A00 011A00 014A00 SMALL ROOFTOP UNITS TWO POSITION OUTDOOR AIR DAMPER 2to15TONS (50/60 Hz) Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... 1 PACKAGE USAGE... 1 SAFETY CONSIDERATIONS...

More information

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD36, FSD36LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 2 PPLICTION Ruskin FSD36 Series low leakage

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air

More information

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction. Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Volume Flow Limiters Type VFL

Volume Flow Limiters Type VFL X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered

More information

INFINITY ZONING QUICK START GUIDE

INFINITY ZONING QUICK START GUIDE Infinity Zoning Quick Start Page 1 of 7 INFINITY ZONING QUICK START GUIDE INTRODUCTION Infinity Zoning incorporates cutting edge technology that sets it apart from any other zoning system on the market

More information

RM-1200 Slim Round Control Damper

RM-1200 Slim Round Control Damper RM-1200 Slim Round Control Damper Product Bulletin Code No. LIT-12011358 Issued June 16, 2008 Since 1905, Johnson Controls has developed and refined air control products by providing the highest quality

More information

PIM Pressure Independent Module

PIM Pressure Independent Module PIM Pressure Independent Module PIM : Product Overview BENEFITS AT A GLANCE QUIET VAV DIFFUSER OPERATION The PIM Pressure Independent Module is a modulating static pressure controller/actuator that allows

More information

RD-2000 Round Control Dampers

RD-2000 Round Control Dampers RD-000 Round Control Dampers Product Bulletin Code No. LIT-8105 Issued February 5, 010 Supersedes July, 009 Johnson Controls provides top-quality, low-leakage RD-000 Round Control Dampers for use in Heating,

More information

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh) Product Data WEATHERMASTER 36S Water Control Induction Air Terminals 19.4 to 131.9 cfm (1770 to 8900 Btuh) Induction air terminals offer: Heating and cooling operation 2-pipe or 4-pipe system options Automatic

More information

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter Product Data FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration Sizes 014, 017, 021 & 024 FNCCAB Filter Cabinet FILCCFNC Media Filter Copyright 2004 Carrier Corporation Form FNCB-1PD FNCCAB Model number

More information

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation

More information

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply

More information

FNCCAB and FILXXFNC High Efficiency Fan Coil Filtration Sizes 14, 17, 21 and 24. Product Data A FNCCAB Filter Cabinet

FNCCAB and FILXXFNC High Efficiency Fan Coil Filtration Sizes 14, 17, 21 and 24. Product Data A FNCCAB Filter Cabinet FNCCAB and FILXXFNC High Efficiency Fan Coil Filtration Sizes 14, 17, 21 and 24 Product Data A10045 FNCCAB Filter Cabinet FILTER CABINET (FNCCAB) MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 F

More information

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL SYSTXCCITC01---B Infinityr System Control Product Data A11577 NOTE: Infinityr System Control compatible with Infinityr rated indoor equipment only. US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr

More information

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL FAN COILS ACCESSORY ELECTRIC HEATERS WIRING DIAGRAMS FIG. FIELD-INSTALLED HEATER MODEL FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL 1 KFCEH0401N03A 18,24 x 001 x 19,25 18,24 18,19,24,25 x 340816-101

More information

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should

More information

FSD60/MFSD60 Multi-blade Fire Damper

FSD60/MFSD60 Multi-blade Fire Damper DAMPER FSD60/MFSD60 Multi-blade Fire Damper Tested and conform to Tested and conform to BS476:Part20:1987 The ASLI Multi-Blade Fire Dampers have been developed to provide the versatility required for today

More information

LOUVERED FACE GRILLES AND REGISTERS

LOUVERED FACE GRILLES AND REGISTERS Performance Notes for Supply rilles and Registers, 6 and 67 Series Throw, Spread and Drop The isovel diagrams shown below, illustrate in plan view, the relationship of horizontal spread to throw for three

More information

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 APPLICATION Ruskin model TED50XT is a low leak, thermally efficient damper with insulated extruded aluminum blades specially

More information

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

PC-125x Counter-Balanced Backdraft Damper

PC-125x Counter-Balanced Backdraft Damper PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls

More information

Start-Up, Operation and Service Instructions

Start-Up, Operation and Service Instructions Article I. Krueger Proportional LineaHeat W/ Discharge Temperature Start-Up, Operation and Service Instructions SAFETY NOTE Air-handling equipment will provide safe and reliable service when operated within

More information

Variable Air Volume Dampers

Variable Air Volume Dampers OVAV 2000 SERIES OPTIMA VAV DAMPERS Overview OPTIMA make Variable Air Volume (OVAV) box is a part of an Air Conditioning system. It is located inside the duct work. VAV Dampers are designed to control

More information

Introduction to Johnson Controls Dampers

Introduction to Johnson Controls Dampers Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader

More information

INLET BOXES AND INLET-BOX DAMPERS

INLET BOXES AND INLET-BOX DAMPERS INLET BOXES AND INLET-BOX DAMPERS Available on these Arrangement 1, 4, 8, 9, 9F, and 10 fans: GENERAL PURPOSE FANS ACOUSTAFOIL/PLR FANS CLASS IV FANS AF FANS RTS FANS GI FANS HPBC FANS BC FANS BCPB FANS

More information

Air Quality Solutions

Air Quality Solutions Air Quality Solutions Installation & Maintenance Manual Model: IAQ50X Air Measuring Station Indoor Air Quality Damper II-IAQ50X-818/Replaces II-IAQ50X-612 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Product Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL

Product Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL SYSTXBBUIZ01 -D Evolutiont Zone Control Product Data A10287 NOTE: Evolutiont Zone Control compatible with Evolution rated indoor equipment only. EVOLUTION t ZONE CONTROL Bryantr specializes in creating

More information

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers

More information

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1. LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE TALE OF CONTENTS RETROFIT/YPASS TERMINAL UNITS RVE This retrofi t terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable volume systems and also

More information

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM 42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette

More information

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

CONTROL DAMPERS. Models 1810 & Model Model Model 1370 CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

AD-1251 Probe with Differential Pressure Transducer

AD-1251 Probe with Differential Pressure Transducer AD-1251 Probe with Differential Pressure Transducer Product Bulletin Code No. LIT-12011473 Issued October 31, 2011 Supersedes September 6, 2011 The AD-1251 Probe with Differential Pressure Transducer (DPT)

More information

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control GC Infinityr Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.8-4.7, 18.5-32.0 EER (Closed Loop) S 4.5-5.2, 23.1-37.0 EER (Open Loop) S Optional

More information

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101) 500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Installation Instructions

Installation Instructions CRPWREXH08A0, CRPWREXH09A0, CRPWREXH08A00, CRPWREXH08A00 For Use With Horizontal EconoMi$er IV, EconoMi$er, or EconoMi$er X (W70) Installation Instructions TABLE OF CONTENTS PACKAGE CONTENTS... PACKAGE

More information

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter Product Data FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner Sizes 016, 020, 024 FILCAB Filter Cabinet EZ Flex Expandable Filter FILCAR Media Filter Copyright 2002 Carrier Corporation Form FLCB-1PD

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control Product Data A12479 NOTE: Evolutionr Connext Control compatible with Evolutionr rated equipment only. US Patents: Carrierr U.S.

More information

YCCS Zone/Bypass Damper Assembly

YCCS Zone/Bypass Damper Assembly YCCS Zone/Bypass Damper Assembly UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x The York Commercial Comfort System (YCCS) Zone/Bypass Damper Assemblies are zone control and pressure control devices that

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Venturi FX VFX Series v100 Issue Date: 11/22/16 2016 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Safety Precautions... 1 Caution to Contractors...1

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Product Information. Applications. Warranty. Lab Calibrated. Residential, Commercial, OEM. ABV Sizes Available Airflow Range THE USA PROUDLY MADE IN

Product Information. Applications. Warranty. Lab Calibrated. Residential, Commercial, OEM. ABV Sizes Available Airflow Range THE USA PROUDLY MADE IN PROUDLY MADE IN R38089 THE USA Classified by UL to UL 2043 for heat release rate and smoke optical density. ABV-4 ABV-5 ABV-6 Product Information The ABV Automatic Balancing Valves maintain a constant

More information

MOTORIZED VOLUME DAMPER

MOTORIZED VOLUME DAMPER MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers

More information

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated

More information

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS D2 RETROFIT/YPASS TERMINA UNITS Table of Contents RETROFIT/YPASS TERMINA UNITS RVE This retrofit terminal unit is designed to convert high pressure mechanical constant volume systems to low pressure variable

More information

Solutions from SPTT-3

Solutions from SPTT-3 Solutions from SPTT-3 System Principle Of Operation Sdhv 21 60000 BTU 9 9 2000 BTU 10 2 Conventional D/T/R Diffusion, Throw & Return. Air change. Works for heating OR cooling, NOT BOTH. Aspiration Static

More information

EGG CRATE RETURN GRILLE

EGG CRATE RETURN GRILLE 80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders

More information

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section SECTION 15910 DUCT ACCESSORIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division-1 Specification Sections,

More information

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control GZ Infinityr Series Geothermal Split Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.3-4.6, 14.8-28.8 (Closed Loop) S 3.8-5.2, 19.2-29.1 (Open Loop) S Optional

More information

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information