U L OIL-FIRED FURNACES. Stellar MBH OUTPUT 80 AFUE DESCRIPTION FEATURES MULTI-POSITION MODELS - P1FM DOWNFLOW/HORIZONTAL MODELS - P1FH

Size: px
Start display at page:

Download "U L OIL-FIRED FURNACES. Stellar MBH OUTPUT 80 AFUE DESCRIPTION FEATURES MULTI-POSITION MODELS - P1FM DOWNFLOW/HORIZONTAL MODELS - P1FH"

Transcription

1 TGY (795) MULTI-POSITION S - PFM Stellar 2000 OIL-FIRED FURNES MH OUTPUT 80 FUE U L DOWN/HORIZONTL S - PFH DESRIPTION These oil-fired furnaces are compact, decorator-styled warm air heating units designed for installation in basements, closets, recreation rooms or garages. The complete selection consists of two types of furnaces with 4 available models. Heating capacities range from 55 through 200 MH bonnet output. ll models are designed to accomodate add-on air conditioning. The capacities, cfm s and performance are matched to meet year-round comfort requirements. fter the installation of an oil-fired furnace, the air conditioner may be added at any time by adding a compact cooling coil to the furnace, and a small quiet condensing section outside the home. FETURES LO-OY S PFL DEORTOR-STYLED SING is 22-gauge pre-painted steel for a long lasting a durable finish. ompletely insulated to keep heat inside, the exterior casing is at room temperature and cool to the touch. PFH models have exposed burner controls. DRWER-TYPE SSEMLY in the air tube of the burner groups oil lines, fittings, and other components into one assembly for easy inspection and flame adjustment. POWERFUL DIRET DRIVE ENTRIFUGL LOWERS are engineered for smooth, whisper-quiet operation. Dynamically and statically balanced, rubber isolator mounted, permanently lubricated, it is ideally suited for both heating and cooling service. MULTI-POSITION S allow all applications with a single unit. Easy conversion with minimum change required. URNER VESTIULE permits total encasement of parts for neat appearance while protecting burner and other parts from dust and dirt. EKETT FLME RETENTION HED URNER is standard on all models, finely atomizes the fuel oil for complete combustion, providing high efficiency. TWO-STGE FUEL PUMPS are standard on 50 MH and larger furnaces. ONSTNT LOW LOWER SPEED OPERTION for maximum comfort (may be turned off if desired). DMIUM SULFIDE FLME DETETOR cuts off burner motor in 45 seconds if the oil fails to ignite. The entire furnace is fitted with the latest in automatic controls to assure safe, continuous operation. ELETRONI FN ONTROL for both comfort and maximum efficiency. HET EXHNGER is constructed of aluminized steel. ll seams are mechanically sealed eliminating welding. OMUSTION HMER is made of alumina silica fibers which will withstand temperatures up to 2600 F to contain the intense flame created by the retention head burner. FOR DISTRIUTION USE ONLY - NOT TO E USED T POINT OF RETIL SLE

2 TGY RTINGS ND PHYSIL DT HETING MH OIL FM UNIT MX. WIRE LOWER DD-ON INPUT OUTPUT RTE 85.5 IWG MP- OVER- SIZE FILTERS OOLING GPH % 2 TEMP E.S.P. 3 ITY URRENT WG SIZE HP QTY. & TONS NOM. RISE PROTET. SIZE FM UP/DOWN/HORIZONTL PFMD2F x 9 /3 () 8 x 25 2,2-/2,3 200 PFMD2F x 9 /3 () 8 x 25 2-/2,3,3-/2 200 PFMD6F x 9 /2 () 20 x 29 3-/2,4 600 PFMD20F x 2 3/4 () 20 x 29 3-/2,4, DOWN/HORIZONTL PFHD2F x 9 /3 () 8 x 25 2,2-/2,3 200 PFHD2F x 9 /3 () 8 x 25 2-/2,3,3-/2 200 PFHD6F x 9 /2 () 20 x 29 3-/2,4 600 PFHD8F x 9 3/4 () 20 x 29 3-/2,4,5 800 UP/HORIZONTL PFMD20F x 2 3/4 N/ 3-/2,4, PFMD20F x 2 3/4 N/ 3-/2,4, LO-OY PFLD2F x 9 /3 () 8 x 25 2,2-/2,3 200 PFLD2F x 9 /3 () 8 x 25 2-/2,3,3-/2 200 PFLD6F x 9 /2 () 20 x 30 3-/2,4 600 PFLD20F x 2 /2 () 20 x 30 3-/2,4, For ltitudes above 2000 feet, reduce ratings 4% for each 000 feet above sea level. 2 FUE (nnual Fuel Utilization Efficiency) determined using DOE test procedure, isolated combustion. 3 vailable external static pressure is at furnace outlet and ahead of cooling unit. PFH DOWN/HORIZONTL PFM - UP/HORIZONTL (50& 200 MH) LOWOY D E 7/8 D IR E 2 ELETRIL WIRING H* (FLUE DI.) H (FLUE DI.) URNER OIL ONNETION OIL INLET ELETRIL WIRING F G I G F IR J * May be field converted to rear flue outlet 2 Unitary Products Group

3 TGY DIMENSIONS - INHES D E F G Ι J H HEIGHT WIDTH DEPTH SUPPLY IR OTTOM RETURN FLUE SIDE RETURN WIDTH DEPTH WIDTH DEPTH HEIGHT WIDTH UP/DOWN/HORIZONTL PFMD2F / /8 7-/ /4 PFMD2F / /8 7-/ /4 PFMD6F / /8 22-/ /4 PFMD20F / /8 22-/ /4 DOWN/HORIZONTL END RETURN PFHD2F /4* PFHD2F /4* PFHD6F /4* PFHD8F /4* UP/HORIZONTL PFMD20F / /8 29-/ /4 PFMD20F / /8 29-/ /4 LO-OY SUPPLY IR RETURN IR PFLD2F / PFLD2F / PFLD6F / PFLD20F / * NOTE: For "FH" models, add 6-5/8" for burner. PFM UP/DOWN/HORIZONTL PFL LOWOY KNOKOUT OTH SIDES & TOP FOR FLUE D IR E 2 H (FLUE DI.) F IR G IR 3 E D 2 OIL INLET ELETRIL WIRING I J G F H (FLUE DI.) ELETRIL WIRING OIL INLET Unitary Products Group 3

4 TGY MINIMUM LERNES TO OMUSTILES LERNES FROM UP DOWN HORIZONTL Top of furnace casing or plenum 2" 2" 2" Top of horizontal warm-air duct within 6 ft. of furnace 2" 2" 3" Flue pipe, measured horizontally or below pipe 4" 4" 4" Flue pipe, measured vertically above pipe 8" 8" 8" ny side of supply plenum and warm-air duct within 6 ft of furnace " 4" " Front of furnace 8" 8" 24" Sides of furnace 0" " 2" Rear of furnace 0" " 0" ottom of furnace 0" 2 0" 0" 2 2 Floor shall be non-combustible, except when installed on non-combustible floor base. floor may be combustible and 4" decreased to 2". Floor may be combustible. FIELD WIRING DIGRM TYPIL WIRING ND PIPING 4 Unitary Products Group

5 TGY LOWER PERFORMNE UP/DOWN/HORIZONTL PFMD2F0550 PFMD2F0850 PFMD6F000 PFMD20F250 LOWER EXTERNL STTI PRESSURE SPEED LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH DOWN/HORIZONTL PFHD2F0550 PFHD2F0730 PFHD6F000 PFHD8F250 LOWER EXTERNL STTI PRESSURE SPEED LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH UP/HORIZONTL PFMD20F500 & PFMD20F200 LOWER EXTERNL STTI PRESSURE SPEED LOW MED HIGH LOW-OY PFLD2F0550 PFLD2F0850 PFLD6F000 PFLD20F250 LOWER EXTERNL STTI PRESSURE SPEED LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH NOTES:. ir flows in FM 2. ir flow measured without filters in place. Unitary Products Group 5

6 TGY ESSORIES - FOR FIELD INSTLLTION THERMOSTTS Remote, wall-mounted, low voltage, for both heating/cooling applications. Refer to Thermostat Price Page. OMUSTILE FLOOR SE For installation of downflow furnaces on a combustible floor. 2-STGE FUEL PUMPS Single stage pump in all 55 thru 23 MH output units. Field convert single stage to two-stage by ordering part number , or latest number. 6 Unitary Products Group

7 TGY NOTES Unitary Products Group 7

8 Unitary Products Group P.O. ox 592, York, Pennsylvania US Subject to change without notice. Printed in U.S.. opyright by York International orporation 995. ll Rights Reserved. EY,EGY TGY (795) Supersedes: TGY (094)

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This

More information

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICL GUIDE SPLIT-SYSTEM EVPORTOR LOWERS K*ES120 10 NOMINL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling coil

More information

TECHNICAL GUIDE MODELS: MA MODULAR AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MA MODULAR AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TEHNIL GUIDE MODELS: MODULR IR HNDLERS FOR USE WITH SPLIT SYSTEM OOLING & HET PUMP 600-2000 FM BLOWERS 2-5 TON OILS OPTIONL 1 & 3φ ELETRI HETERS ISO 9001 ertified Quality Management System Due to continuous

More information

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TEHNIL GUIDE MODELS: MV MODULR VRIBLE SPEED IR HNDLERS FOR USE WITH SPLIT SYSTEM OOLING & HET PUMP 1200-2000 FM BLOWERS 3-5 TON OILS OPTIONL 1 & 3 ELETRI HETERS Due to continuous product improvement, specifications

More information

TECHNICAL GUIDE 80 AFUE MULTI-POSITION GAS FURNACES MODELS: G8C SERIES 4-POSITION MBH INPUT 3-POSITION 150 MBH INPUT DESCRIPTION WARRANTY

TECHNICAL GUIDE 80 AFUE MULTI-POSITION GAS FURNACES MODELS: G8C SERIES 4-POSITION MBH INPUT 3-POSITION 150 MBH INPUT DESCRIPTION WARRANTY TEHNIAL GUIE 80 AFUE MULTI-POSITION GAS FURNAES MOELS: G8 SERIES 4-POSITION 50-125 MH INPUT 3-POSITION 150 MH INPUT EFFIIENY RATING ERTIFIE ISO 9001 ertified Quality Management System ESRIPTION These compact

More information

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units

More information

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21053-001 Rev. A (4/00) DESCRIPTION These high efficiency, dedicated downflow compact units employ induced combustion, reliable hot surface ignition and high heat transfer tubular heat exchangers.

More information

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev. TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose

More information

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303) TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION DESCRIPTION These high efficiency, dedicated downflow compact units employ induced

More information

Product Data 58GFA. Induced-Combustion Upflow Furnace Heating Inputs: 65,000 thru 150,000 Btuh. 78% AFUE With Continuous- Pilot Ignition

Product Data 58GFA. Induced-Combustion Upflow Furnace Heating Inputs: 65,000 thru 150,000 Btuh. 78% AFUE With Continuous- Pilot Ignition Product Data 58GF Induced-ombustion Upflow Furnace Heating Inputs: 65,000 thru 150,000 Btuh 78% FUE With ontinuous- Pilot Ignition arrier is the first manufacturer to provide a 78% nnnual Fuel Utilization

More information

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE / SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel

More information

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

12 SEER CENTRAL AIR CONDITIONING TON

12 SEER CENTRAL AIR CONDITIONING TON 12 SEER ENTRL IR ONDITIONING 1.5-5 TON QULITY FETURES Efficient scroll compressors Full metal louvered coil protection Quiet, top air discharge Galvanized steel cabinet with corrosion resistant powder

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. VL8FA119P60B / VL8RA119P60B (BECKETT AFG) HEATING CAPACITY High Fire * Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 OUTPUT BTUH 1 132,000 119,000 101,000 SEASONAL EFFICIENCY

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) VHF-ANP / VHF-ANE (BECKETT NX) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000

More information

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY VLF-CBP (Front Flue) or VLR-CBP (Rear Flue) High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. VH8FA119P60B VH8FA119T60B (BECKETT AFG) HEATING CAPACITY High Fire * Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 OUTPUT BTUH 1 132,000 119,000 101,000 SEASONAL EFFICIENCY

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES TEHNIAL GUIDE SINGLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLING & HEAT PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 DESRIPTION This fan coil line offers the ultimate in application flexibility.

More information

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces Heating Input: 40,000 140,000 TU/h //GHS8 Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas valve Norton hot

More information

4000-Series ir Handling Systems ooling, Energy Recovery, Heating & Pressurization Dimension and Selection Guide 1.800.536.3461 www.rapidengineering.com ND: 100% OUTSIDE IR ONLY 4000-Series Fan Selection

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

80% Oil Furnace RLBF(R)

80% Oil Furnace RLBF(R) 80% Oil Furnace Basement-Direct & Belt Drive RLBF(R) FEATURES AND BENEFITS Heavy-duty 14 gauge steel heat exchanger with a long lasting ceramic fiber combustion chamber Easy access large diameter clean

More information

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h Heating Input: 40,000 0,000 TU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 96% FUE ontents Nomenclature... ccessories... Product Specifications... imensions... 4 irflow ata... 5 Wiring iagrams...

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG) MODEL NO. THV1C072A948SA (BECKETT AFG) THV1C072A9V4SA (BECKETT AFG) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000

More information

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH) 1 SEASONAL EFFICIENCY 2 LARGEST REC A/C 3 FUEL

More information

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. CMC1-50D36 (DV3) CMC1-75D36 (DV3) HEAT INPUT RATE (BTUH) 50,000 75,000 OUTPUT (BTUH)

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTUH

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

80% Oil Furnace Basement - Belt & Direct Drive LBF(R) HEAT EXCHANGER CABINET BLOWER BURNER CONTROLS VENTING INSTALLATION ACCESSORIES WARRANTY

80% Oil Furnace Basement - Belt & Direct Drive LBF(R) HEAT EXCHANGER CABINET BLOWER BURNER CONTROLS VENTING INSTALLATION ACCESSORIES WARRANTY 80% Oil Furnace Basement - Belt & Direct Drive LBF(R) HEAT EXCHANGER Heavy-duty 4 gauge steel with a long lasting ceramic fiber combustion chamber Easy access large diameter clean out ports CABINET Foil-faced

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED BOY FURNACE SPECIFICATIS MODEL NO. HEATING CAPACITY TLF1M087C942SA TLR1M087C942SA High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire High Fire Med-High Fire TLF1M087D9V5SA [6] TLR1M087D9V5SA

More information

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Product Data Upflow/ Horizontal Left/Right, Downflow Two Condensing Gas Fired Furnace Upflow, Convertible to HorizontalRight or HorizontalLeft S9V2B040U3PSBB S9V2B060U3PSBB S9V2B060U4PSBB S9V2B080U3PSBB

More information

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

FG7T (E and N Series)

FG7T (E and N Series) TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency

More information

OIL FURNACES Clean, Comfortable Oil Heat

OIL FURNACES Clean, Comfortable Oil Heat OIL FURNACES Clean, Comfortable Oil Heat Features Foil-faced high density fiberglass insulation to minimize noise and heat loss Heavy duty 14 gauge steel heat exchanger engineered for efficiency; covered

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTUH

More information

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.

More information

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Cabinet Features. Certified for direct vent (2-pipe) or Two-stage gas valve provides quiet,

Cabinet Features. Certified for direct vent (2-pipe) or Two-stage gas valve provides quiet, 96V omfortnet -ompatible Two-Stage, Variable-Speed EM-based Gas Furnace Up to 96% FUE Heating Input: 0,000 0,000 TU/h ontents Nomenclature... ccessories... Product Specifications... imensions... irflow

More information

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Product Data. that this product meets the S 95% AFUE S Two -stage operation DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling

More information

KG7S (A and K Series)

KG7S (A and K Series) TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed

More information

FG7S (C and L Series)

FG7S (C and L Series) TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000

More information

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized

More information

93% Gas Furnaces Single Stage

93% Gas Furnaces Single Stage Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 93% Gas Furnaces Single Stage Form No. AA931A-100 (05/2012) HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped

More information

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. OL6*A072D48/DV5 B OL6*A072D48/DV5 R OL6*A072D48/DV5 C HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000

More information

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING (598) STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING HEAT PUMP S: F2RP / F2FP018 THRU 060 COOLING S: F2RC / F2FC018 THRU 036 VARIABLE SPEED : F2FV060 DESCRIPTION This fan coil

More information

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS CEW SERIES CEILING EXPOSED HORIZONTL FN COIL UNITS MGIC IRE BMW SERIES FN COILS RE ETLC LISTED IN CCORDNCE WITH UL 1995 ND RE SSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPNY, L.P. 501

More information

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless

More information

G8MVL. Product Specifications

G8MVL. Product Specifications 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE / 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000

More information

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE VENTING WARRANTY GENISYS ADVANCED BURNER CONTROL CONFIGURATIONS HEAT EXCHANGER CABINET BLOWER BURNER

L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE VENTING WARRANTY GENISYS ADVANCED BURNER CONTROL CONFIGURATIONS HEAT EXCHANGER CABINET BLOWER BURNER L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE FORM NO. L83-100 (07/2014) VENTING Includes field installed barometric damper Optional sidewall vent kit available WARRANTY 10 year limited parts warranty / lifetime

More information

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 45,000 1,000 BTUH The GMS8/GDS8/GHS8 single-stage, multi-speed gas furnaces offer installation versatility.

More information

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING 92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped

More information

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) FORM NO. G66-544 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h // Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h / Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) C9MVX SoftSound VS90 Product Specifications 95% Variable Speed Two Stage Heating Furnace FLEXIBILITY Supports two stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40in (1016mm)

More information

XV 80 TDD2B060,080, C100,D120A9V

XV 80 TDD2B060,080, C100,D120A9V Downflow/Horizontal Right or Left 2-Stage Variable Speed Gas-Fired Furnace XV 80 TDD2B060,080, C100,D120A9V Two-Stage Fan Assisted Combustion System PUB. NO. 22-1673-10 General Features NATURAL GAS MODELS

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 1 Supersedes Form No. G66-478 Rev. 0 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing line of upflow/horizontal gas furnaces are designed for utility rooms, closets,

More information

83% Oil Furnace. Features. Configurations. Cabinet. Blower. Burner

83% Oil Furnace. Features. Configurations. Cabinet. Blower. Burner 83% Oil Furnace Features Configurations Upflow / Highboy Basement / Lowboy Horizonal / Counterflow Heat Exchanger Heavy-duty 14 gauge steel with a long lasting ceramic fiber combustion chamber Easy access

More information

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods

Wall Hoods INSTALLING HOOD CANOPY. Island Hoods HEIGHT OF HOOD The bottom of the hood to should be 30 (76.2 cm) to 36 (91.4 cm) above the countertop. This would typically result in the bottom of the hood being 66 (167.6 cm) to 72 (182.9 cm) above the

More information

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces THIS MODEL 78% 82% 88% 92.0% 97% Air Gas Furnaces Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces RGPQ- Series 80% A.F.U.E. Models with Input Rates from 45-105 kbtu (U.S. & Canadian Models)

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE

More information

AMVC8/ADVC8. Heating Input: 60, ,000 BTU/h

AMVC8/ADVC8. Heating Input: 60, ,000 BTU/h MV8/DV8 Heating Input: 60,000 00,000 TU/h Two-Stage Variable Speed Gas Furnace 80% FUE Standard Features Two-stage gas valve operates on twostage or single-stage thermostats omfortnet ommunications System

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FGT (A and K Series) Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The high efficiency

More information

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11

More information

FG7T (A and K Series)

FG7T (A and K Series) TECHNICAL SPECIFICATIONS FG7T (A and K Series), Smartlite Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing

More information

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA TDD-D-1 Vertical boy, boy Front Flue, boy Rear Flue, Downflow/Horizontal Oil-Fired Furnace XP80 / XV80 boy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA Downflow/Horizontal Front Flue TDF1M087A936,V3,SA

More information

SINGLE-WIDTH FANS WITH

SINGLE-WIDTH FANS WITH ULLETIN MV-08 OTOER, 06 SINGLE-WIDTH FNS WITH OUSTFOIL //PLR WHEELS apacities to 00,000 Three wheel choices Static pressures to 4 WG,, 3 construction 7 FTORY STREET L PORTE, INDIN 46350 PHONE: [9] 36-767

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 156,250 140,000 119,000 156,250 140,000 119,000

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor 80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor A80-1E Form No. A80-1E-100 (10/2011) Features and Benefits CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped

More information

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information