OIL FIRED LOWBOY FURNACE SPECIFICATIONS
|
|
- Jason Bishop
- 5 years ago
- Views:
Transcription
1 OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY VLF-CBP (Front Flue) or VLR-CBP (Rear Flue) High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140, , ,000 84,000 OUTPUT BTUH [1] 114,000 98,000 88,000 70,000 SEASONAL EFFICIENCY [2] LARGEST REC A/C [3] NOMINAL TEMP RISE HEAT EXCHANGER AREA (SQ. FT.) CASING HEIGHT CASING WIDTH CASING DEPTH NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT (LBS) APPROVAL AGENCY QTY AND SIZE OF PERMANENT FILTERS ELECTRICAL REQUIREMENTS TOTAL CURRENT (AMPS) MAX FUSE SIZE (AMPS) HEIGHT FROM FLOOR TO CENTER OF FLUE SUPPLY AIR OUTLET SIZE RETURN AIR INLET SIZE FURNACE PARTS KIT OPTIONAL 4 TON AIRFLOW KIT BURNER FRESH AIR VENT KIT BLOCKED VENT KIT [4] FF / RF 85.00% 4 Tons 70 F 27.8 (front flue) / 30.0 (rear flue) ETL (2) 10 X v / 60hz / 1ph " 20 X x 12.5 ACCESSORY ITEMS AOPS2695 S00S4141 AOPS7482 AOPS2687 / AOPS OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY M ANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTM ENT OF ENERGY TEST PROCEDURES. 3 TO PERM IT LARGEST RECOM M ENDED AIR CONDITIONING (AT.5 STATIC PRESSURE), OPTIONAL BLOWER UGRADE KIT IS REQUIRED. 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIM NEY VENTED. 5 AFUE RATINGS AS SHIPPED. SEE NEXT PAGE FOR MORE DATA- PS ECN 5412-MA
2 OIL FIRED HORIZONTAL/COUNTERFLOW FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 119, ,000 84,000 OUTPUT BTUH[1] 97,000 88,000 69,000 SEASONAL EFFICIENCY[2] LARGEST REC A/C[3] NOMINAL TEMP RISE HEAT EXCHANGER AREA (SQ. FT.) CASING HEIGHT VC-CBP (BECKETT AFG) 85.0% 4 Tons (in horizontal configuration, flue exits horizontally forw ard) (in counterflow /vertical configuration) CASING WIDTH CASING DEPTH NOMINAL FLUE OUTLET DIA. APPROX SHIPPING WEIGHT (LBS) APPROVAL AGENCY QTY AND SIZE OF PERMANENT FILTERS ELECTRICAL REQUIREMENTS TOTAL CURRENT (AMPS) MAX FUSE SIZE (AMPS) HEIGHT FROM FLOOR TO CENTER OF FLUE SIDE/TOP SUPPLY AIR OUTLET SIZE RETURN AIR INLET SIZE FURNACE PARTS KIT COMBUSTIBLE FLOOR BASE OPTIONAL 4 TON AIRFLOW KIT BURNER FRESH AIR VENT KIT BLOCKED VENT KIT[4] (in horizontal configuration) (in counterflow /vertical configuration) ETL NONE SUPPLIED 120v / 60hz / 1ph (in horizontal configuration flue exits horizontally forw ard) 30.5 (in counterflow /vertical configuration, flue exits horizontally) 16 X X 16 ACCESSORY ITEMS AOPS2695 VC-BASE S00S4140 AOPS7482 AOPS OUTPUT BTUH BASED ON ANNUAL FUEL UTILIZATION EFFICIENCY RATED BY MANUFACTURER. 2 SEASONAL EFFICIENCY (ALSO CALLED AFUE - ANNUAL FUEL UTILIZATION EFFICIENCY) RATINGS ARE BASED ON TESTS FOLLOWING U.S. DEPARTMENT OF ENERGY TEST PROCEDURES. 3 TO PERMIT LARGEST RECOMMENDED AIR CONDITIONING (AT.5 STATIC PRESSURE), OPTIONAL BLOWER UPGRADE KIT IS REQUIRED 4 NOT TO BE USED IN SIDEWALL VENT APPLICATIONS, USE ONLY WHEN CHIM NEY VENTED. 5 AFUE RATINGS AS SHIPPED. SEE NEXT PAGE FOR MORE DATA- 2
3 Model Number Digit Model Configuration Flue Design Change Burner Blower Motor Oil Furnace Model Nomenclature Example Model Numbers V L F - C B P V=Product Line Designation L = Lowboy, C = Counterflow/Horizontal F = Front, R = Rear (VL series option only) Design Change Burner Type: B= Beckett AFG Motor Type: P=PSC, T= CTM (Constant torque ECM) V L F - C B P SEE NEXT PAGE FOR MORE DATA- 3
4 OIL FIRED LOWBOY FRONT FLUE FURNACE SPECIFICATIONS 4 SEE NEXT PAGE FOR MORE DATA-
5 OIL FIRED LOWBOY REAR FLUE FURNACE SPECIFICATIONS 5 SEE NEXT PAGE FOR MORE DATA-
6 OIL FIRED HORIZONTAL/COUNTERFLOW FURNACE SPECIFICATIONS COMBUSTIBLE FLOOR BASE 6 SEE NEXT PAGE FOR MORE DATA-
7 BLOWER DATA: VLF-CBP VLR-CBP VC-CBP BLOWER MODEL DIRECT DRIVE MOTOR H.P. MOTOR TYPE & NUMBER OF SPEEDS HIGH SPEED AIRFLOW 0.5 IN. W.G. EXTERNAL STATIC PRESSURE: 10-9R ½ HP Permanent split capacitor, BLOWER DATA: OPTIONAL 4TON AIRFLOW KIT BLOWER MODEL DIRECT DRIVE 10-9R 10-9R 12-9T MOTOR H.P. MOTOR TYPE & NUMBER OF SPEEDS HIGH SPEED AIRFLOW 0.5 IN. W.G. EXTERNAL STATIC PRESSURE: ¾ HP Permanent split capacitor, BURNER DATA AIR TUBE LENGTH (IN.) BURNER HEAD TYPE: FUEL TYPE: R.W. BECKETT pressure atomizing type, Model AFG 5.875, effective Fixed, flame retention #2 distillate (domestic heating oil) NOZZLE RATING (GPH): SPRAY ANGLE (DEG.): SPRAY PATTERN: OIL PUMP PRESSURE (PSIG): COMBUSTION CHAMBER TYPE: 80 HOLLOW 130 PSI Preformed, refractory (ceramic fiber matrix material) CLEARANCES SIDES FRONT (SERVICE ACCESS) REAR FLUE TOP PLENUM SIDES PLENUM VLF-CBP VLR-CBP VC-CBP MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: SEE NEXT PAGE FOR MORE DATA- 7
8 VLF-CBP 3.5 Ton ALTERATIONS REQ D FOR DESIGN EXTERNAL STATIC PRESSURE Heating Speed by Input Recommended CLG COOLING UNIT Low Fire ML Fire MH Fire High Fire Speed 84, , , ,000 24,000 Low ML MH High Low 30,000 Low ML MH High ML 36,000 Low ML MH High MH 42,000 Low ML MH High High 48,000 Low Furnace Airflow (CFM) vs. External Static pressure (in. WC.) ML MH High Blower Motor Current Draw (Amps) vs. External Static (in. WC.) Low ML MH High SEE NEXT PAGE FOR MORE DATA - 8
9 VLF-CBP 3.5 Ton High Fire (140,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-High Fire (119,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-Low Fire (105,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Low Fire (84,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Recommended Operation Range SEE NEXT PAGE FOR MORE DATA - 9
10 VLF-CBP 4 Ton ALTERATIONS REQ D FOR DESIGN EXTERNAL STATIC PRESSURE Heating Speed by Input Recommended CLG COOLING UNIT Low Fire ML Fire MH Fire High Fire Speed 84, , , ,000 24,000 Low ML MH High Low 30,000 Low ML MH High Low 36,000 Low ML MH High ML 42,000 Low ML MH High MH 48,000 Low ML MH High High Furnace Airflow (CFM) vs. External Static pressure (in. WC.) Low ML MH High Blower Motor Current Draw (Amps) vs. External Static (in. WC.) Low ML MH High SEE NEXT PAGE FOR MORE DATA - 10
11 VLF-CBP 4 Ton High Fire (140,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-High Fire (119,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-Low Fire (105,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Low Fire (84,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Recommended Operation Range SEE NEXT PAGE FOR MORE DATA 11
12 VLR-CBP 3.5 Ton ALTERATIONS REQ D FOR DESIGN EXTERNAL STATIC PRESSURE Heating Speed by Input COOLING UNIT Low Fire ML Fire MH Fire High Fire Recommended CLG Speed 84, , , ,000 24,000 Low ML MH High Low 30,000 Low ML MH High ML 36,000 Low ML MH High MH 42,000 Low ML MH High High 48,000 Furnace Airflow (CFM) vs. External Static pressure (in. WC.) Low ML MH High Blower Motor Current Draw (Amps) vs. External Static (in. WC.) Low ML MH High SEE NEXT PAGE FOR MORE DATA 12
13 VLR-CBP 3.5 Ton High Fire (140,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-High Fire (119,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-Low Fire (105,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Low Fire (84,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Recommended Operation Range SEE NEXT PAGE FOR MORE DATA 13
14 VLR-CBP 4 Ton ALTERATIONS REQ D FOR DESIGN EXTERNAL STATIC PRESSURE Heating Speed by Input COOLING UNIT Low Fire ML Fire MH Fire High Fire Recommended CLG Speed 84, , , ,000 24,000 Low ML MH High Low 30,000 Low ML MH High Low 36,000 Low ML MH High ML 42,000 Low ML MH High MH 48,000 Low ML MH High High Furnace Airflow (CFM) vs. External Static pressure (in. WC.) Low ML MH High Blower Motor Current Draw (Amps) vs. External Static (in. WC.) Low ML MH High SEE NEXT PAGE FOR MORE DATA 14
15 VLR-CBP 4 Ton High Fire (140,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-High Fire (119,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-Low Fire (105,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Low Fire (84,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Recommended Operation Range SEE NEXT PAGE FOR MORE DATA 15
16 VC-CBP 3.5 Ton ALTERATIONS REQ D FOR DESIGN EXTERNAL STATIC PRESSURE Heating Speed by Input Recommended COOLING UNIT Low Fire ML Fire MH Fire High Fire CLG Speed 80, , ,000 24,000 Low High MH Low 30,000 Low High MH Low 36,000 Low High MH MH 42,000 Low High MH High 48,000 Furnace Airflow (CFM) vs. External Static pressure (in. WC.) Low ML MH High Blower Motor Current Draw (Amps) vs. External Static (in. WC.) Low ML MH High SEE NEXT PAGE FOR MORE DATA 16
17 VC-CBP 3.5 Ton Med-High Fire (119,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-Low Fire (105,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Low Fire (84,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Recommended Operation Range SEE NEXT PAGE FOR MORE DATA 17
18 VC-CBP 4 Ton ALTERATIONS REQ D FOR DESIGN EXTERNAL STATIC PRESSURE Heating Speed by Input COOLING UNIT Low Fire ML Fire MH Fire High Fire Recommended CLG Speed 84, , ,000 24,000 Low ML MH Low 30,000 Low ML MH Low 36,000 Low ML MH ML 42,000 Low ML MH MH 48,000 Low ML MH High Furnace Airflow (CFM) vs. External Static pressure (in. WC.) Low ML MH High Blower Motor Current Draw (Amps) vs. External Static (in. WC.) Low ML MH High SEE NEXT PAGE FOR MORE DATA 18
19 VC-CBP 4 Ton Med-High Fire (119,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Med-Low Fire (105,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Low Fire (84,000 BTU/HR Input) Temp Rise vs. External Static pressure (in. WC.) Low ML MH High Recommended Operation Range 19
OIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED BOY FURNACE SPECIFICATIS MODEL NO. HEATING CAPACITY TLF1M087C942SA TLR1M087C942SA High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire High Fire Med-High Fire TLF1M087D9V5SA [6] TLR1M087D9V5SA
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
MODEL NO. VL8FA119P60B / VL8RA119P60B (BECKETT AFG) HEATING CAPACITY High Fire * Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 OUTPUT BTUH 1 132,000 119,000 101,000 SEASONAL EFFICIENCY
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. VH8FA119P60B VH8FA119T60B (BECKETT AFG) HEATING CAPACITY High Fire * Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 OUTPUT BTUH 1 132,000 119,000 101,000 SEASONAL EFFICIENCY
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG)
MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) VHF-ANP / VHF-ANE (BECKETT NX) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTUH
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG)
MODEL NO. THV1C072A948SA (BECKETT AFG) THV1C072A9V4SA (BECKETT AFG) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTUH
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. OL6*A072D48/DV5 B OL6*A072D48/DV5 R OL6*A072D48/DV5 C HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 156,250 140,000 119,000 156,250 140,000 119,000
More informationGAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS
GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. CMC1-50D36 (DV3) CMC1-75D36 (DV3) HEAT INPUT RATE (BTUH) 50,000 75,000 OUTPUT (BTUH)
More informationGAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS
GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH) 1 SEASONAL EFFICIENCY 2 LARGEST REC A/C 3 FUEL
More informationMODEL NO. CLHS1-075T42N CLHS1-100T48N
MODEL NO. CLHS1-075T42N CLHS1-100T48N FUEL GAS NAT/LP 4 GAS NAT/LP 4 INPUT BTUH 75,000 100,000 OUTPUT BTUH 1 73,000 96,000 SEASONAL EFFICIENCY 2 95.0% 95.0% LARGEST REC A/C 3 3.5 T 4 T NOMINAL TEMP RISE
More informationXP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA
TDD-D-1 Vertical boy, boy Front Flue, boy Rear Flue, Downflow/Horizontal Oil-Fired Furnace XP80 / XV80 boy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA Downflow/Horizontal Front Flue TDF1M087A936,V3,SA
More informationTECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION
Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This
More informationTECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION
Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This
More information80% Oil Furnace RLBF(R)
80% Oil Furnace Basement-Direct & Belt Drive RLBF(R) FEATURES AND BENEFITS Heavy-duty 14 gauge steel heat exchanger with a long lasting ceramic fiber combustion chamber Easy access large diameter clean
More informationL83 PRODUCT SPECIFICATIONS 83% OIL FURNACE VENTING WARRANTY GENISYS ADVANCED BURNER CONTROL CONFIGURATIONS HEAT EXCHANGER CABINET BLOWER BURNER
L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE FORM NO. L83-100 (07/2014) VENTING Includes field installed barometric damper Optional sidewall vent kit available WARRANTY 10 year limited parts warranty / lifetime
More information83% Oil Furnace. Features. Configurations. Cabinet. Blower. Burner
83% Oil Furnace Features Configurations Upflow / Highboy Basement / Lowboy Horizonal / Counterflow Heat Exchanger Heavy-duty 14 gauge steel with a long lasting ceramic fiber combustion chamber Easy access
More information80% Oil Furnace Basement - Belt & Direct Drive LBF(R) HEAT EXCHANGER CABINET BLOWER BURNER CONTROLS VENTING INSTALLATION ACCESSORIES WARRANTY
80% Oil Furnace Basement - Belt & Direct Drive LBF(R) HEAT EXCHANGER Heavy-duty 4 gauge steel with a long lasting ceramic fiber combustion chamber Easy access large diameter clean out ports CABINET Foil-faced
More informationAvailable in Upflow/Horizontal and Counterflow/Horizontal models
PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow/Horizontal models 80% AFUE 50,000 to 25,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER Aluminized steel
More informationUpflow, Upflow / Horizontal, Counterflow / Horizontal
Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long
More informationOIL FURNACES Clean, Comfortable Oil Heat
OIL FURNACES Clean, Comfortable Oil Heat Features Foil-faced high density fiberglass insulation to minimize noise and heat loss Heavy duty 14 gauge steel heat exchanger engineered for efficiency; covered
More informationOLR Product Specifications
OLR Product Specifications LO BOY OIL FURNACE C Illustrations and photographs are only representative. Some product models may vary. US 85.0 to 86.8 ONLY applies to applications in Canada where the furnace
More informationChinook Gas Furnace Multi-Position High Efficiency Condensing Furnace
Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace 1 stage PSC CXX-1-D 1 stage ECM CXX-1-X 2 stage PSC CXX-2-D 2 stage ECM CXX-2-V Modulating CXX-M-V, CXX-M-S Modulating Compact CC15-M-V
More informationAF90. AF90 Gas Furnace High Efficiency. Features
AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty
More informationDM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h
/ Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11
More informationN9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationUpflow, Upflow / Horizontal, Counterflow
, / Horizontal, 90/92 Gas Furnace CG90/92 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long life AL29-4C Stainless
More informationVMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h
/ Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...
More informationEasily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency
Gas Furnaces PRODUCT SPECIFICATIONS INSTALLATION OPTIONS A vailable in Upflow/Horizontal and Counterflow models 80% AFUE 44,000 to 32,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER A luminized
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE
COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct
More informationUp to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL
N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved
More informationGF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)
FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces
More informationG95V Series Gas-Fired 95% 2-Stage High Efficiency (Condensing) Multi-Positional Furnace w/ ECM Circulator
5/23/07 G95V Service Parts 1 Key No. Description Cabinet Group Top Panel Left Side Panel Assembly Right Side Panel Assembly Rear Panel Blower Division Panel Assembly,,, Base Panel,, Upper Front Door Panel,
More informationOperating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16
SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationCooling Capacity CFM in. w.c. (125 Pa)
95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationCooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)
80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal
More informationCooling Capacity CFM in. w.c. (125 Pa)
95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationGMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h
// Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...
More informationGMH8/GDH8 MULTI-POSITION, MULTI-SPEED GAS FURNACES 80% AFUE HEATING INPUT: 40, ,000 BTU/H. Standard Features. Cabinet Features.
HEATING INPUT: 40,000 140,000 BTU/H /GDH8 MULTI-POSITION, MULTI-SPEED GAS FURNACES 80% AFUE Standard Features - - --- Cabinet Features - - - - Contents 3 5 7 10 11 * -- SS- www.goodmanmfg.com 4/13 Supersedes
More informationCooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)
80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal
More informationAMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h
/ ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11
More information93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS
93% Single Stage Gas Furnace Form No. JA931A-100 (08/2010) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped no
More information93% Gas Furnaces Single Stage
Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 93% Gas Furnaces Single Stage Form No. AA931A-100 (05/2012) HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped
More information95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES
95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)
More informationA95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS
Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for
More informationUPFLOW/ HORIZONTAL GAS FURNACE
FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity
More informationG8MVL. Product Specifications
80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in
More information92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING
92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped
More information80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor
80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor A80-1E Form No. A80-1E-100 (10/2011) Features and Benefits CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped
More information80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS
80% Gas Furnace Single Stage - High Efficiency (Constant Torque) Motor 80G1-E Features and Benefits Form No. R80G1-E-100 (11/2011) CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped
More informationTSTAT0101SC Recommended (sold separately)
Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation
More information95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger
Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized
More informationF8MTL. Product Specifications
80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115
More informationWFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty
95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to
More information95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER
95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe
More informationGMS9/GCS9 SERIES 93% AFUE
/ SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel
More informationWFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN
92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to
More information95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER
95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized
More informationDUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH
FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL
More informationWFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty
92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to
More informationCooling Capacity CFM in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More information95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS
A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless
More informationTable of Contents GF801U Series
FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed
More informationGMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace
Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 92% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage
More informationUPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)
C9MVX SoftSound VS90 Product Specifications 95% Variable Speed Two Stage Heating Furnace FLEXIBILITY Supports two stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40in (1016mm)
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationGMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace
Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage
More informationDD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h
Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 100,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8
More informationAMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h
Heating Input: 40,000 140,000 BTU/h /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic
More information80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal
More informationProduct Data. that this product meets the S 95% AFUE S Two -stage operation
DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling
More informationA962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN
A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains
More informationProduct Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat
PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationTECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES
TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated
More informationMulti-Position, Multi-Speed Gas Furnaces
Heating Input: 40,000 140,000 BTU/h / Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve control technology allows installer to
More informationW801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )
FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features
More informationTECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES
TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated
More informationEclipse Vortometric Burners Series HI
Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas)
More informationRheem Value Series Upflow/Horizontal Gas Furnace
THIS MODEL Gas Furnaces Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE 80.0% MID HIGH 78% 82% 88%
More information80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES
FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing
More informationFORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1
FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential
More informationTZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.
FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark
More informationW801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )
FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and
More informationRuud Achiever Plus Series Upflow/Horizontal Gas Furnace
Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationRuud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace
Gas Furnaces Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace U802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationGKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h
Series up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Upflow Multi- Position, Multi-Speed Gas Furnace Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas
More informationGAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization
More informationRheem Classic Plus Series Upflow/Horizontal Gas Furnace
Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationRheem Classic Plus Series Upflow/Horizontal Gas Furnace
Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationGMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE
/ Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 7 Wiring Diagram... 10 Accessories... 11 Minimum Filter
More informationW801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )
FORM NO. G66-544 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential
More information