GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace
|
|
- Charleen Stanley
- 6 years ago
- Views:
Transcription
1 Heating Input: 40, ,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage gas valve Durable Silicon Nitride igniter Quiet single-speed induced draft blower Self-diagnostic control board with constant memory fault code history output to a LED Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier All models comply with California Low NOx emissions standards Cabinet Features Designed for multi-position installation : upflow, horizontal left or right : downflow, horizontal left or right Certified for direct vent (2-pipe) or non-direct vent (1-pipe) Easy-to-install top venting with optional side venting Convenient left or right connection for gas and electrical service Cabinet air leakage (Q Leak ) 2% Heavy-gauge steel cabinet with durable finish Fully insulated heat exchanger and blower section Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications... 7 Wiring Diagram...10 Accessories...11 * Complete warranty details available from your local dealer or at To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS- 9/14
2 Nomenclature G M S S B N A A ,6 7,8, Brand Minor Revision G - Goodman A - Initial Release B - 1st Revision Configuration M - Upflow/Horizontal Major Revision C - Downflow/Horizontal A - Initial Release B - 1st Revision Motor V - Variable Speed ECM / ComfortNet NOx E - Multi- Speed ECM N - Low NOx S - Single Speed Cabinet Width Gas Valve B " M - Modulating C - 21" C - 2 Stage D " S - Single Stage AFUE Maximum CFM 92-92% AFUE CFM 96-96% AFUE CFM 97-97% AFUE CFM CFM MBTU/h ,000 BTU/h ,000 BTU/h ,000 BTU/h 2 SS-
3 Specifications BNA 0603BNA 0803BNA 0804CNA 0805CNA 1005CNA 1205DNA Heating Data High Fire Input¹ 40,000 60,000 80,000 80,000 80, , ,000 High Fire Output¹ 38,400 57,600 76,800 76,800 76,800 96, ,200 AFUE² Temperature Rise Range ( F) Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 3" No. of Burners Circulator Blower Available 0.5" ESP Size (D x W) 10" x 8" 10" x 8" 10" x 8" 10" x 10" 11" x 10" 11" x 10" 11" x 11" 1075 RPM ⅓ ⅓ ½ ½ ¾ ¾ ¾ Speed Filter Size (in²) Permanent ,024 Disposable Electrical Data Min. Circuit Ampacity⁴ Max. Overcurrent Device (amps)⁵ Shipping Weight (lbs) ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. ⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½" FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS- 3
4 Specifications BNA 0603BNA 0804CNA 1005CNA 1205DNA Heating Data High Fire Input¹ 40,000 60,000 80, , ,000 High Fire Output¹ 38,400 57,600 76,800 95, ,000 AFUE² Temperature Rise Range ( F) Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 3" No. of Burners Circulator Blower Available 0.5" ESP Size (D x W) 10" x 8" 10" x 8" 10" x 10" 11" x 10" 11" x 11" 1075 RPM ⅓ ⅓ ½ ¾ ¾ Speed Filter Size (in²) Permanent Disposable Electrical Data Min. Circuit Ampacity⁴ Max. Overcurrent Device (amps)⁵ Shipping Weight (lbs) ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. ⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½" FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. 4 SS-
5 Dimensions AIR DISCHARGE AIR DISCHARGE 28¾ AIR INTAKE 2" PIPE LEFT SIDE DRAIN TRAP EXTERI HOLES 6½ 2¾ 2⅝ 2 CENTER DIMPLE F ALTERNATE AIR INTAKE PIPE 3" OD HOLE HIGH VOLTAGE ELECTRICAL OUTLET STANDARD GAS SUPPLY LOCATION A DIM B DISCHARGE C 1⅞ ¾ 2 6½ 19½ VENT/FLUE PIPE 2" PVC ALTERNATE VENT/FLUE ¾ LOCATION RIGHT SIDE DRAIN TRAP EXTERI HOLES HIGH VOLTAGE ELECTRICAL OUTLET ALTERNATE GAS SUPPLY ¾ 34½ 14 1½ SIDE CUT-OUT 5 9¼ 19⅝ 23 24⅞ 31⅞ 26½ 23 21⅛ 19⅝ 9¼ 5 SIDE CUT-OUT 1⅜ LEFT SIDE VIEW LOW VOLTAGE ELECTRICAL OUTLET 23 1⅞ 2⅜ 2½ CONDENSATE DRAIN TRAP EXTERI CONNECTION (RIGHT LEFT SIDE) ¾ PVC FRONT VIEW D FOLDED FLANGES E UNFOLDED FLANGES ⅞ LOW VOLTAGE ELECTRICAL OUTLET 1⅞ 2⅜ 2½ RIGHT SIDE VIEW 22 FOLDED FLANGES 23½ UNFOLDED FLANGES Model A B C D E 0402BNA 17½ 16" 13⅞" 12⅛" 13⅝" 0603BNA 17½ 16" 13⅞" 12⅛" 13⅝" 0803BNA 17½ 16" 13⅞" 12⅛" 13⅝" 0804CNA 21" 19½" 17⅜" 16" 17½" 0805CNA 21" 19½" 17⅜" 16" 17½" 1005CNA 21" 19½" 17⅜" 16" 17½" 1205DNA 24½" 23" 20⅞" 19⅜" 20⅞" Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0" 0" 3" C 0" 1" Horizontal 6" 0" 3" C 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. SS- 5
6 Dimensions 1⅜ 1½ TOP VIEW 23 2⅝ 1⅞ FRONT VIEW A C 1⅝ 2½ 1⅞ LOW VOLTAGE ELECTRICAL OUTLET 6½ RIGHT SIDE VIEW ALTERNATE VENT/ FLUE LOCATION 14 SIDE CUT-OUT LOW VOLTAGE ELECTRICAL OUTLET ALTERNATE GAS SUPPLY LOCATION HIGH VOLTAGE ELECTRICAL OUTLET 34½ 25⅛ ALTERNATE GAS SUPPLY LOCATION SIDE CUT-OUT 14¾ 25⅛ 14⅞ 14¾ 4⅛ 6⅞ 11⅜ 11⅜ 6⅞ LEFT SIDE EXTERI DRAIN TRAP HOLES STANDARD DRAIN TRAP CONNECTION ¾ PVC 28¾ LEFT SIDE VIEW AIR DISCHARGE 2 2½ 3½ D FOLDED FLANGES E UNFOLDED FLANGES FRONT VIEW HIGH VOLTAGE ELECTRICAL OUTLET 2 2⅝ RIGHT SIDE EXTERI DRAIN TRAP HOLES 18⅛ FOLDED FLANGES 20⅛ UNFOLDED FLANGS RIGHT SIDE VIEW AIR DISCHARGE Model A B C D E 0402BNA 17½" 14⅝" 14" 14½" 16" 0603BNA 17½" 14⅝" 14" 14½" 16" 0804CNA 21" 18⅛" 17½" 18" 19½" 1005CNA 21" 18⅛" 17½" 18" 19½" 1205DNA 24½" 21⅝" 21" 21½" 23" Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0" 0" 3" NC 0" 1" Horizontal 6" 0" 3" C 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. 6 SS-
7 Airflow Data Model 0402BNA 0603BNA 0803BNA 0804CNA 0805CNA 1005CNA 1205DNA ¹ at 0.5" ESP Motor Speed Tons AC¹ (CFM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water Column) CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1,478 N/A 1, , , , ,129 1, Med 2.5 1, , , , , , Med-Lo 2 1, , , Low High 3 1, , , , , , Med 2.5 1, , , , , Med-Lo 2 1, , , Low High 3 1, , , , , ,239 1, Med 2.5 1, , , , , ,166 1, Med-Lo 2 1, , , , , ,112 1, Low 1.5 1, , , , ,067 N/A High 4 1, , , , , ,371 1,295 1,160 Med 2.5 1, , , , , , Med-Lo N/A 877 N/A 867 N/A 870 N/A 863 N/A Low N/A 595 N/A 620 N/A 620 N/A 610 N/A High 5 2, , , , , ,850 1,753 1,651 Med 4 1, , , , , ,551 1,485 1,384 Med-Lo 3.5 1, , , , , ,338 1,280 1,204 Low 3 1, , , ,255 N/A 1,208 N/A 1,171 1,104 1,051 High 5 2, , , , , ,775 1,661 1,558 Med 4 1, , , , , ,605 1,514 1,410 Med-Lo 3.5 1, , , , , ,367 1,296 1,219 Low 3 1,390 N/A 1,344 N/A 1,326 N/A 1,268 N/A 1,227 N/A 1,194 1,132 1,071 High 5 2, , , , , ,817 1,724 1,595 Med 4 1, , , , , ,645 1,548 1,454 Med-Lo 3.5 1, , , , , ,409 1,331 1,236 Low 3 1, ,382 N/A 1,345 N/A 1,311 N/A 1,272 N/A 1,215 1,159 1,066 Notes CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. The above chart is for U.S. furnaces installed at feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. SS- 7
8 Airflow Data Model 0402BNA 0603BNA 0804CNA 1005CNA 1205DNA ¹ at 0.5" ESP Motor Speed Tons AC¹ (CFM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water Column) CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1, , , , , , Med 2.5 1, , , , , Med-Lo 2 1, , , Low High 3 1, , , , , , Med 2.5 1, , , , Med-Lo 2 1, Low N/A 788 N/A 765 N/A 720 N/A High 4 1, , , , , ,314 1,226 1,119 Med 3.5 1, , , , , ,282 1, Med-Lo 3 1, , , , , ,199 1, Low 2.5 1, , , , , , High 5 2, , , , , ,659 1,556 1,448 Med 4 1, , , , , ,415 1,335 1,220 Med-Lo 3.5 1, , , , , ,275 1,194 1,093 Low 3 1, , , ,242 N/A 1,173 N/A 1,108 1, High 5 2, , , , , ,739 1,646 1,561 Med 4 1, , , , , ,543 1,436 1,349 Med-Lo 3.5 1, , , , , ,374 1,302 1,204 Low 3 1, , ,371 N/A 1,319 N/A 1,264 N/A 1,208 1,153 1,061 Notes CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. The above chart is for U.S. furnaces installed at feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 8 SS-
9 Temperature Rise Range Chart BTU BTU OUTPUT Output vs Vs. TEMPERATURE Temperature Rise RISE Chart CHART 600 CFM CFM FMULAS BTU BTU/h OUTPUT Output = = CFM x x Rise x RISE RISE Rise = = Formulas BTU OUTPUT BTU/H Output 1.08 CFM x 1.08 CFM OUTPUT Output BTU/h BTU/HR x 1,000 x 1000 TEMPERATURE Temperature Rise RISE SS- 9
10 Wiring Diagram 24V THERMOSTAT CONNECTIONS C G R W RD GND BR BR DIAGNOSTIC LED COL CODES: YL YELLOW ANGE PU PURPLE GN GREEN BLACK 24 VAC 115 VAC 115 VAC HOT AND PARK TERMINALS COOL-H CAPACIT GND ID BLOWER PRESSURE SWITCH HEAT-H BLOWER COMPARTMENT BURNER COMPARTMENT N O 24 VAC HUMIDIFIER FUSE (HI) BL (MED) (MED LOW) RD (LOW) CIRCULAT BLOWER AUTO RESET PRIMARY LIMIT CO NTR O L C2 2 CIRCUIT CONNECT HOT SURFACE IGNITER GAS VALVE YL LINE-H PK PINK BR BROWN ITE BL BLUE GY GRAY RD RED RD 1 PK INDUCED DRAFT BLOWER C Y INTEGRATED CONTROL MODULE 24 VAC HUMIDIFIER GY PK AUXILIARY LIMIT CONTROLS BL PU MANUAL RESET ROLLOUT LIMIT CONTROL(S) ( SINGLE CONTROL ON 40K BTU ) GND RD GR BLOWER COMPARTMENT DO SWITCH (OPEN EN DO OPEN) BL 24V THERMOSTAT CONNECTIONS PK 115 VAC NEUTRAL TERMINALS XFMR-H 40 VA TRANSFMER RD GY PK BL GR YL INTEGRATED CONTROL MODULE LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION EQUIPMENT GND FIELD GND IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE NOTES: 1. SET HEAT ANTICIPAT ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTUR'S SPECIFIED REPLACEMENT PARTS MUST BE USED EN SERVICING. 3. IF ANY OF THE IGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPER CONDUCTS ONLY. 4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CRECT HEATING TEMPERATURE RISE AND THE CRECT COOLING CFM. 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFM TO N.E.C. AND LOCAL CODES. TH (3) XFMR-H EAC-H LINE-H WARNING: DISCONNECT POWER BEFE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. JUNCTION BOX GR GND FLAME SENS DO SWITCH FS IGN IND TR (6) GND (8) MVC (9) HLO (1) RO2 (11) RO1 (5) COOL HEAT-H JUNCTION BOX L GND N INTEGRATED CONTROL MODULE DISCONNECT TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE WARNING:DISCONNECT POWER BEFE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. DISCONNECT AUXILIARY LIMIT CONTROLS FLAME SENS HOT SURFACE IGNITER ID BLWR GND PS (10) C NO PSO (4) HLI (7) MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON 40K BTU) 24 VAC 115 VAC CIRCULAT BLWR 40 VA TRANSFMER N GND L FIELD SPLICE SWITCH (TEMP.) AUTO RESET PRIMARY LIMIT CONTROL INTEGRATED CONTROL MODULE GR RD YL BL STEADY ON = NMAL OPERATION OFF = CONTROL FAILURE 1 FLASH = 2 FLASHES = PRESSURE SWITCH STUCK CLOSED 3 FLASHES = PRESSURE SWITCH STUCK OPEN 4 FLASHES = OPEN HIGH LIMIT 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 6 FLASHES = 7 FLASHES = 7 FLASHES = LOW FLAME SIGNAL 8 FLASHES = 8 FLASHES = CHECK IGNITER IMPROPER GROUNDING CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY SYSTEM LOCKOUT (RETRIES EXCEEDED) OPEN ROLLOUT GY BR MI GY YL NO C PU BR BL GY BR FRONT COVER PRESSURE SWITCH C G Y W R TO MICRO MV(12) HUMIDIFIER N O FRONT COVER PRESSURE SWITCH ELECTRONIC AIR CLEANER C C2 GAS VALVE M1 ID BLOWER PRESSURE SWITCH LINE NEUTRALS TO 115 VAC / 1Ø / 60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 0140F01908-A 10 SS-
11 Accessories / Model Description 0402BNA 0603BNA 0803BNA 0804CNA 0805CNA 1005CNA 1205DNA CVENT-2 Concentric Vent Kit (2") --- CVENT-3 Concentric Vent Kit (3") CFSB17 Downflow Sub-Base 17.5" CFSB21 Downflow Sub-Base 21" CFSB24 Downflow Sub-Base 24" RF Drain Kit -Horizontal Left Vertical Flue EFR01 External Filter Rack with 16"x25" Permanent Filter TBD TBD TBD TBD TBD TBD TBD 0170K00000S Flush Mount Vent Kit - 3" or 2" 0170K00001S Flush Mount Vent Kit - 2" --- AFE18-60A Fossil Fuel (Duel Fuel) Kit High-Altitude Natural Gas Kit TBD TBD TBD TBD TBD TBD TBD High-Altitude Pressure Switch TBD TBD TBD TBD TBD TBD TBD High-Altitude LP Gas Kit TBD TBD TBD TBD TBD TBD TBD LPLP03 Low LP Gas Pressure Switch LPM-07 LP Conversion Kits (Gas Valve) FTK04 Twinning Kit Model Description 0402BNA 0603BNA 0804CNA 1005CNA 1205DNA CVENT-2 Concentric Vent Kit (2") --- CVENT-3 Concentric Vent Kit (3") CFSB17 Downflow Sub-Base 17.5" CFSB21 Downflow Sub-Base 21" CFSB24 Downflow Sub-Base 24" RF Drain Kit -Horizontal Left Vertical Flue EFR01 External Filter Rack with 16"x25" Permanent Filter TBD TBD TBD TBD TBD 0170K00000S Flush Mount Vent Kit - 3" or 2" 0170K00001S Flush Mount Vent Kit - 2" --- AFE18-60A Fossil Fuel (Duel Fuel) Kit High-Altitude Natural Gas Kit TBD TBD TBD TBD TBD High-Altitude Pressure Switch TBD TBD TBD TBD TBD High-Altitude LP Gas Kit TBD TBD TBD TBD TBD LPLP03 Low LP Gas Pressure Switch LPM-07 LP Conversion Kits (Gas Valve) FTK04 Twinning Kit SS- 11
12 Notes Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA SS-
GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace
Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 92% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage
More informationGKS9 Series. Upflow Multi-Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h
Series Upflow Multi-Position, Multi-Speed Gas Furnace up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Standard Features Heavy-duty aluminized-steel, dual-diameter, tubular heat exchanger Stainless-steel
More informationGKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h
Series up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Upflow Multi- Position, Multi-Speed Gas Furnace Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas
More informationAKSS92. Single-Stage. Heating Input: 46, ,000 BTU/h. up to 92.1% AFUE
Heating Input: 46,000 115,000 BTU/h Single-Stage Multi-Speed Gas Furnace up to 92.1% AFUE Standard Features Stainless-steel secondary heat exchanger Single-stage gas valve Durable Silicon Carbide ignitor
More informationDM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h
/ Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11
More informationGMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h
// Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...
More informationGMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE
/ Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 7 Wiring Diagram... 10 Accessories... 11 Minimum Filter
More informationAMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h
/ ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11
More informationDD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h
Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 100,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8
More informationVMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h
/ Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...
More informationAMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h
Heating Input: 40,000 140,000 BTU/h /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic
More informationGMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces
Heating Input: 40,000 140,000 TU/h //GHS8 Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas valve Norton hot
More informationMulti-Position, Multi-Speed Gas Furnaces
Heating Input: 40,000 140,000 BTU/h / Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve control technology allows installer to
More informationGMS9/GCS9 SERIES 93% AFUE
/ SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel
More informationDM96HS / DC96HS. Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 10,000 BTU/h Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... 3 Dimensions... 5 Airflow Specifications... 7 Wiring Diagram...
More informationGMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE
/ 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY
More informationAMEC96. Heating Input: 30, ,000 BTU/h
Heating Input: 30,000 0,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace up to 96% AFUE Standard Features Energy-efficient multi-speed EM blower motor Heavy-duty stainless-steel tubular heat exchanger Stainless-steel
More informationDC96HS TWO-STAGE CONVERTIBLE MULTI-SPEED GAS FURNACE UP TO 96% AFUE. Heating Input: 46, ,000 BTU/h
Heating Input: 46,000 5,000 BTU/h Standard Features Heavy-duty stainless-steel dual-diameter, tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage convertible gas valve automatically
More informationGCEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
GE96 Heating Input: 40,000 00,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... 3 Dimensions... 4 Airflow Specifications... 5 Wiring Diagrams...
More informationDC96VE. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
Heating Input: 40,000-00,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... 3 Dimensions... 4 Airflow Specifications... 5 Wiring Diagram...
More informationGKS9 SERIES PRODUCT SPECIFICATIONS 92.1% AFUE SINGLE-STAGE/MULTI-SPEED GAS FURNACE UPFLOW/MULTI-POSITION HEATING INPUT: 46, ,000 BTU/H
SERIES PRODUT SPEIFIATIONS SINGLE-STAGE/MULTI-SPEED GAS FURNAE The Goodman 92.1% AFUE Single-Stage, Multi-Speed Upflow Gas Furnace features a patented aluminized-steel tubular heat exchanger and energy-efficient
More informationCabinet Features. upflow, horizontal left or right matically adjusts to high or low stage
Two-Stage, onvertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 140,000 BTU/h ontents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8
More informationPRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE
GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 45,000 1,000 BTUH The GMS8/GDS8/GHS8 single-stage, multi-speed gas furnaces offer installation versatility.
More informationGMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h
Heating Input: 0,000 0,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 Airflow Specifications... 6 Wiring Diagrams... 0
More informationGMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h
Heating Input: 0,000 0,000 BTU/h Two-Stage, Multi-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 Airflow Specifications... 5 Wiring Diagrams... 6
More informationA95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS
Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for
More information95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES
95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)
More information96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER
96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 96G1E-100 (04/2018) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe
More information95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS
A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless
More informationA962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN
A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains
More informationUPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)
C9MVX SoftSound VS90 Product Specifications 95% Variable Speed Two Stage Heating Furnace FLEXIBILITY Supports two stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40in (1016mm)
More informationKG7T (E and N Series)
TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas
More information95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger
Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized
More informationFG7T (E and N Series)
TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency
More information95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER
95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe
More information95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER
95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized
More informationGUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE
COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct
More informationN9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationProduct Data. that this product meets the S 95% AFUE S Two -stage operation
DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationCooling Capacity CFM in. w.c. (125 Pa)
95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationUp to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL
N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved
More informationTECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY
TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh
More informationFG7S (C and L Series)
TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000
More informationPGC COMMERCIAL PACKAGED GAS/ELECTRIC
PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationKG7T (C and L Series)
TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency
More informationCooling Capacity CFM in. w.c. (125 Pa)
95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationG9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
More informationAF90. AF90 Gas Furnace High Efficiency. Features
AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty
More informationVG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input
TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationKG7T (C and L Series)
TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency
More informationG9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
More informationN9MPD Product Specifications
Single Stage Furnace Multiposition FLEXIBILITY Dual certified venting (1 or 2 pipes) Direct Vent furnace 40 (1016mm) high with wider cabinets, for ease of installation Factory shipped as natural gas, with
More informationA951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN
A951E PRODUCT SPECIFICATIONS SINGLE STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A951E-100 (10/2018) CONTROLS Single stage gas valve Durable silicon nitride ignitor Self diagnostics saves
More informationGMH8/GDH8 MULTI-POSITION, MULTI-SPEED GAS FURNACES 80% AFUE HEATING INPUT: 40, ,000 BTU/H. Standard Features. Cabinet Features.
HEATING INPUT: 40,000 140,000 BTU/H /GDH8 MULTI-POSITION, MULTI-SPEED GAS FURNACES 80% AFUE Standard Features - - --- Cabinet Features - - - - Contents 3 5 7 10 11 * -- SS- www.goodmanmfg.com 4/13 Supersedes
More informationCooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)
80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal
More informationCooling Capacity CFM in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More information93% Gas Furnaces Single Stage
Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 93% Gas Furnaces Single Stage Form No. AA931A-100 (05/2012) HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped
More informationCooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)
80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal
More information92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING
92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped
More informationTECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.
TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose
More informationTSTAT0101SC Recommended (sold separately)
Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation
More informationTECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.
036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units
More informationGF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)
FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces
More informationWFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty
95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to
More informationG8MVL. Product Specifications
80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in
More informationF8MTL. Product Specifications
80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115
More informationWFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty
92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to
More informationWFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN
92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to
More information80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor
80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor A80-1E Form No. A80-1E-100 (10/2011) Features and Benefits CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped
More informationARUF Series Multi-Position
Series Multi-Position Multi-speed Psc Motor Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed PSC blower motor All-aluminum evaporator coil Coil mounting
More informationDUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH
FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL
More informationFG7T (A and K Series)
TECHNICAL SPECIFICATIONS FGT (A and K Series) Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The high efficiency
More information80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS
80% Gas Furnace Single Stage - High Efficiency (Constant Torque) Motor 80G1-E Features and Benefits Form No. R80G1-E-100 (11/2011) CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped
More informationMulti-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor
Multi-Position Air Handler with Energy-Saving Motor ½ to Tons Standard Features Suitable for use with refrigerants R-0A and R- All-aluminum evaporator coil Check flowrater expansion device for cooling
More informationUpflow, Upflow / Horizontal, Counterflow / Horizontal
Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long
More information93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS
93% Single Stage Gas Furnace Form No. JA931A-100 (08/2010) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped no
More informationW801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )
FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and
More informationRheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace
Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationProduct Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat
PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different
More informationXC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace
TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VA, TDHMB060BCV3VA TUHMB080ACV3VA, TDHMB080ACV3VA
More informationAPD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF
APD14 Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 6 Expanded Heating Data... 20 Airflow Data... 22 Dimensions...
More informationFG7T (A and K Series)
TECHNICAL SPECIFICATIONS FG7T (A and K Series), Smartlite Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80 + AFUE Input 60,000-140,000 Btuh The
More informationAWUF Series. Wall-Mount Air Handler 1½- to 3-Tons
Series Wall-Mount Air Handler 1½- to 3-Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Equipped with a check flowrater for cooling-only and heat pump operation Direct-drive, multi-speed
More informationKG7S (A and K Series)
TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed
More informationUpflow, Upflow / Horizontal, Counterflow
, / Horizontal, 90/92 Gas Furnace CG90/92 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long life AL29-4C Stainless
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationWFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design
80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More informationARPT. Multi-Position 1½ to 5 Tons Construction
Multi-Position ½ to 5 Tons Air Handler with new SmartFrame Construction Standard Features Direct-drive, multi-speed motor Internal factory-mounted TXV valve Transformer and blower time-delay on all units
More informationRheem Classic Plus Series Downflow Gas Furnace
Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
More informationAWUF, AWUT Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features
, AWUT Series Wall-Mount Air Handler 1½ to 3 Tons Contents Nomenclature...2 Accessories...2 Product Specifications...3 Dimensions...7 Airflow Data...9 Wiring Diagram...10 Product Features Models: Equipped
More informationTECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)
TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION DESCRIPTION These high efficiency, dedicated downflow compact units employ induced
More informationARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit
More informationASPT Multi-Position Air Handler
Multi-Position Air Handler with Energy-Saving Motor ½ to Tons Standard Features Direct-drive, multi-speed ECM motor Internal factory-mounted TXV valve Transformer and blower time-delay on all units All-Aluminum
More informationW801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )
FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity
More informationPGB SERIES 10 SEER PRODUCT SPECIFICATIONS. Self-Contained Gas/Electric Packaged Air Conditioner
PGB SERIES 0 SEER SelfContained Gas/Electric Packaged Air Conditioner 2 and 5 Ton Cooling Capacity: 2,600 to 58,000 BTUH Heating Input Rates: 6,000 to 0,000 BTUH The PGB outdoor package unit is a selfcontained
More information