1 Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas) Min. Input MM BTU/hr (MW) # Oil 0.3 (0.).0 (0.3) Gas Inlet Pressure Required, " w.c. (mbar) Air Inlet Pressure Required " w.c. (mbar) (5) Combustion Air Flow, 7 scfm (m 3 /min) (3) Natural Gas Flow scfh x 00 (m 3 /hr) (69) No. Fuel Oil 3 Atomizing Air Atomizing Steam 5 Oil Flow GPH (m 3 /hr) Nozzle P psig (bar) Flow scfm (m 3 /hr) 3 (0.6) 5 (.7) 5 () ).5 (0.) 97 (56).5 (96) 75 (0.8) (.) 39 (66) 0.8 (0.).5 (0.7) 393 (90) 7.0 (79) (0.6) (3.8) 63 (7).0 (0.3) 3.0 (0.9) 3 () 3 (69) 6 (0.6) (3.8) 85 ().3 (0.).0 (.) (70) 3 (903) 9 (0.87) (3.8) 8 (0).5 (0.) 5.5 (.6) 7889 (3) (85) 0 (.) (63).0 (0.6) 7.0 (.) 33 (9) () 393 (.9) (33).7 (0.8) (.9) 65 (5) 78 (0) 7 (.) 88 (89) 3.0 (0.9) (3.5) 6905 (79) 90 (538) 63 (.3) 33 (56) 5.0 (.5) 6 (.7) 379 (665) 5 (6) 893 (3.38) 6 (783) (.8) (5.9) 053 (85) (3) 3 (.33) 590 (0) 7.0 (.) (7.6) 39 (7) (593) 500 (5.68) 775 (36) P psig (bar) (3.) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) Flow lbs/hr (kg/hr) 7 (33) 3 (5) 8 (83) 8 3 (56) (6) 59 (69) 8 (38) 97 () 0 (6) 78 (78) 68 (9) P psig (bar) (3.) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) (3.8) Combustion Air Temp., F ( C) 6 < 500 () Process Temperature, F ( C) Refractory Lined Combustor <,0 (0) High Fire Flame Length, 5.0 Feet (m) 7 (.6) High Fire Flame Diameter, Inches (m) (0.8) (.9) 3 (0.8) 7.0 (.) 36 (0.9) 8.0 (.5) 0 (.0) Fuel Lance Configurations Gas Only Gas lance only supplied. Fuel ports sized for natural gas. For other gases, contact Eclipse. Oil Only Oil lance is supplied with support tube arrangement. Gas and Oil CGO (Combined Gas and Oil) lances are provided for burning both gas and oil. Pilot All Burners Natural gas or propane 8 Approvals 9.0 (.8) 6 (.) (3.) 5 (.3) (3.) (.5) 3 (.0) 6 (.6) (.3) 68 (.8) 6 (.9) 78 (.0) Datasheet 8-7/6/ Eclipse Vortometric Burners Series HI 7 (5.) 86 (.) (6.) 96 (.5). Natural gas capacities are based on gross heating value (00 BTU/scf, 0.6 specific gravity).. Combustion air flows and pressure drops at 5% excess air through the mixing tube at standard conditions (70 F,.7 psia). 3. Oil firing capacities for No. fuel oil with gross heating value of 0,000 BTU/gal. Maximum 50 SSU viscosity required for all oils.. Atomizing air must be supplied in a clean/dry condition. 5. Steam must be supplied at a minimum F (-6.7 C) above saturated temperature. 6. Contact Eclipse for burner sizing and recommendations for preheated air over 0 F (50 C). 7. Flame lengths provided are estimates based on general operating conditions and are useful for design purposes. Actual flame lengths will depend on chamber size and presence of secondary air. 8. See Design Guide 8 for more information about typical fuel composition and properties. Burner minimum inputs stated for modulating combustion air. Air and natural gas pressure drops should be taken as a differential pressure between the air/gas at the burner and the chamber pressure. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obligated to adjust earlier supplies accordingly.
2 00 Operational Envelope Performance Graphs 0 NO X Emissions, Natural Gas vs. Firing Rate Excess Air (%) 0 Typical NO X 3% O 80 Typical Firing Rate (% of High Fire) Firing Rate (%) Burner emissions depend on and are affected by operational and applicational conditions. Contact Eclipse for specific emissions estimates for your application. 6V 8V V V V 6V 8V V V 8V 3V 36V Combustion Air Pressure Drop vs. Burner Heat Input for High Intensity Burners (HI) Operation with 5% excess air on natural gas or # oil under standard conditions,.7 psia, 70 F (3 mbar, C) Pressure drop should be taken between the chamber and windbox pressure tap (tap A) Combustion Air Pressure Drop (mbar) Combustion Air Pressure Drop (" w.c.)* Burner Gross Heat Input (MM BTU/hr) 0. 0 Eclipse Vortometric Series HI, V3, Datasheet 8-, 7/6/
3 Gas Lance Pressure Drop vs. Burner Heat Input Pressure drops for natural gas,,000 BTU/scf gross(0.8 kw/m²), 0.6 specific gravity. Pressure drop should be taken as differential between the chamber and gas lance pressure tap (tap B). Note: Fuel pressure drop curves should be used as a guide for setting up burner. It is recommended to use a direct fuel flow measurement (orifice plate or flow meter) for determining actual fuel flows. 70 6V 8V V V V 6V Gas Lance Pressure Drop (mbar) Gas Lance Pressure Drop (" w.c.) Burner Gross Heat Input (MMBTU/hr) V V V 8V 3V 36V 0 Gas Lance Pressure Drop (mbar) Gas Lance Pressure Drop (" w.c.) Burner Gross Heat Input (MMBTU/hr) 0 Eclipse Vortometric Series HI, V3, Datasheet 8-, 7/6/ 3
4 5 Oil Nozzle Pressure Drop Vs. Burner Heat Input Pressure drops for # Oil with 0,000 BTU/gal (3,500 kj/l). gross heating value (tap C). V 8V 6V V V V 3V 8V 36V Oil Nozzle Pressure (bar) Oil Nozzle Pressure Drop (psig) V 8V V Burner Gross Heat Input (MMBTU/hr) S P Holes of R Dia. Equally Spaced on FF Bolt Circle NOTE: Fuel pressure drop curves should be used as a guide for setting up burner. It is recommended to use a direct fuel flow measurement (orifice plate or flow meter) for determining actual fuel flows. A A Tap A Windbox Pressure Tap 3/" NPT 5 Pilot UV Scanner (Typ. Locations) N O.D. of Windbox C NPT/BSP Oil Inlet Tap C M Space Req d. to Remove Oil Lance AIR INLET - TOP VIEW AA Dia. x MM Z Holes -/ NPT Peepsight (Typ. Locations) Dimensions D NPT/BSP Pilot Gas Inlet B NPT/BSP Atomizing Air or Steam Outlet Gas Lance NN SECTION A-A REFRACTORY COMBUSTOR CC T K Air Inlet A Gas Inlet Tap B L LL I.D. F KK ±" to suit wall JJ I.D. Hold ±/" GG Combustor O.D. FF Bolt Circle Dia. EE Flange O.D. W V 3 U T BB Atomizer (For Oil Only) X 3 Y J H G Eclipse Vortometric Series HI, V3, Datasheet 8-, 7/6/
5 Burner Size Dim 6V 8V V V V 6V 8V V V 8V 3V 36V A -/ (DIN0) (DIN0) (DIN0) 6 (DIN50) 6 (DIN50) 6 (DIN50) 8 (DIN0) B 3/ 3/ -/ -/ C / / 3/ 3/ 3/ -/ -/ -/ -/ D 3/ 3/ 3/ 3/ 3/ 3/ 3/ -/ -/ -/ -/ -/ F 5 (7) G 3-3/ (39) H 3 (90) J 9-/ (9) K 5-5/6 () L 9 (7) M 8 (708) N 9 (737) -5/8 (3) -5/8 (3) 3-/8 (9) -3/8 (568) 5-5/6 () -3/ (98) 9-/ (750) 3 (86) 7-/8 () 5-7/8 (03) 7-/8 (97) 3 () 5-5/6 () -/ (3) 33-/ (88) 0 (6) -5/8 (5) 8-/8 (6) 9 (6) 3-/8 (7) 5-5/6 () -3/ (96) 36-/ (9) (3) 5-/ (68) -3/ (3) -/8 (0) -5/8 (59) 5-5/6 () -/8 (8) 38 (96) 5 (3) 8-5/8 (76) -/ (63) (5) -/8 (6) 7-3/ (97) -3/ (98) 3-/ (0) 57 (8) Burner size 8V through V are NPT or BSP threaded; all other sizes are ANSI, RF, or DIN 50 lbs flanged. These dimensions can vary ±.5" (38 mm)since gas lance position is adjustable. Indicates number of spaces, " ( mm) apart. Ensure that furnace wall inside diameter is " (5 mm) greater than GG. See Section 3 of Installation Guide 8. An ultraviolet flame sensing device (UV scanner) may be mounted to two locations. Two scanner mounting ports (3/" NPT) are located near the gas assembly adjacent to the pilot. The pilot scanner location can be used to prove both the pilot and the main flame. 33-5/8 (85) 7-3/8 (695) 6 (67) 5-/ (6) 9-/8 (3) -7/8 () 6-/ (75) 6-/8 (69) 0-5/8 (3) 3-3/8 (8) 70-7/8 (800) 7-3/8 (696) -/ (67) () 50-/ (8) 75 (905) 3 (9) (887) 76 (9) 9-5/8 (75) (5) -/ (3) 56-/ (37) 80 (3) 50-/ (83) -3/8 (50) 8-7/8 (56) 8 (7) -/ (3) 3-/8 (3) 6 (57) 9-/8 (39) -3/ (6) 6-5/8 (85) 9 (3) 9-3/8 (7) -3/ (98) -3/8 (365) 68 (78) (6) 65 (65) 53 (37) (590) 3-3/ (853) 3-/ (337) (3) 77 (950) 8 (997) P R /6 (7) /6 (7) /6 (7) /6 (7) /6 (7) /6 (7) /6 (7) /6 (7) /6 (7) /6 (7) /6 (7) /6 (7) S 8 (7) T 9 (9) -3/ (57) 9 (9) -/ (6) (5) 8 (7) 5 (38) 3 (83) 8 (7) (889) (533) 39 (99) -/ (6) 6-/ (8) (76) 9 () 33 (838) (73) 38-/ (978) 65 (65) (3) 7 (880) 5-/ (8) U (533) (533) 5 (6) 8 (7) 3 (83) 36 (9) 0 (6) 7 (9) 50 (70) 59 (99) 65 (65) 7 (880) V W -3/ (73) -3/ (73) 3-3/ (39) 6-3/ (5) -/ (5) 3-/ 6-3/ (679) 3-3/ (83) -3/ (908) -/ (8) 7-3/ (3) X Y -3/ (578) -3/ (578) 6-3/ (679) 9-3/ (756) 3-/ (870) 38-/ (97) -/ (73) 9-3/ (6) 5-3/ () 6-3/ (568) 67-3/ (7) 5-/ (378) 79 (07) Z (6) (6) 8 (7) 3 (787) 36 (9) 0 (6) (8) 5 (3) (3) 6 (66) 6 (66) 69 (75) AA 7/6 () 7/6 () 7/6 () 7/6 () 7/6 () 7/6 () 7/6 () 9/6 () 9/6 () 9/6 () 9/6 () 9/6 () BB (5) CC 8-3/ (76) EE 3 (86) FF 3-/ (800) GG -/ (66) (5) 5-/ (6) 39 (99) 36-/ (97) -3/8 (77) 5 (38) 33 (838) (3) -/ (80) -3/8 (899) 8 (7) 38-3/ (98) 50 (70) 7-/ (7) 39-3/8 (00) (9) 7-3/8 (3) (73) (397) -3/8 (53) 5 (6) 53-/8 (39) 63 () (5) 50-3/8 (80) 8-/ (7) 6-5/6 (7) 70 (778) 67 (70) -3/8 (07) (889) 73-3/6 (859) 8 (57) 78 (98) 6-3/8 (6) 38 (965) 77-7/8 (978) 89 (6) 83 (8) 67-3/8 (7) 3-/ (5) 9-3/ (3) 0 (50) 97 (6) 80-3/8 () 50 (70) -/ () (79) 7 (78) 88-3/8 () 56-/ (36) 8 (998) (0) (73) 98-/3 (98) JJ 6 (06) (533) 6 (6) (76) 36 (9) () 6 (68) (397) (73) 68 (77) 76 (9) 86 (8) KK -/ (368) (9) 6-/ (673) (76) 36 (9) () 6 (68) (397) (73) 68 (77) 76 (9) 7 (880) LL 6 (5) 8 (3) (5) (5) (6) 6 (06) 8 (8) (9) (6) 8 (7) 3 (83) 36 (9) MM NN 3 (8) 5 (9) 5.75 (7) 5.75 (7) (5) (5) (5) (5) (80) (5) (5) (6) Eclipse Vortometric Series HI, V3, Datasheet 8-, 7/6/ 5
6 Burner Size Pilot Capacity Burner Input BTU/hr (kw) Size Main Burner Pilot 6V 6,000,000 (,757),000 (7.6) 8V,500,000 (3,075) 5,000 (.7) V 3,000,000 (6,7),000 (67.3) V 3,000,000 (9,370) 3,000 (93.7) 6V,000,000 (,98),000 (3.0) 8V,000,000 (6,5) 0,000 () V 78,000,000 (,839) 780,000 (8.) V 90,000,000 (6,3) 900,000 (63.5) 8V 5,000,000 (36,),50,000 (36) 3V,000,000 (6,850),0,000 (68.5) 36V,000,000 (6,90),0,000 (6.9) Burner Weights Less Refractory/Air Cooled lbs (kg) Refractory lbs (kg) 6V 0 (0) 98 () 8V 6 (88) 673 (759) V 85 (386) 390 (8) V 0 (99) (06) V 68 (666) 9 (97) 6V 8 (8) 500 (9) 8V 85 (7) 7 (37) V 33 (5) 98 (65) V (9) 365 (5) 8V 5 (50) 8 (89) 3V 690 (9) 6 (05) 36V 83 (3893) 998 (3) Datasheet 8-, 7/6/
Eclipse RatioAir Burners
Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire
More informationRatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750
Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact
More informationRatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000
Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.
More informationEclipse RatioAir Burners
Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged
More informationData 330-3 9/15/07 Eclipse ImmersoJet Burners Model 3 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr)
More informationData /1/07 Eclipse RatioAir Burners Model RA0040
Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged Minimum input, () Lower inputs may be achieved. Contact factory. Main Gas Inlet
More information1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER
CAPABILITIES Industry leading low NOx emissions High momentum. luminous flames at all furnace temperatures High release rates with moderate main combustion air pressure Good turndown with flame characteristics
More informationMULTIFIRE. High temperature dual fuel burner
MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,
More informationDesign and Application Details
Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.
More informationCapacities and Operating Data
CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000
More informationBurner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110
NOTES: Burner Capacity Information, BBC 111/211 NATURAL GAS, AMBIENT COMBUSTION AIR OPERATION, LOW PRESSURE ATOMIZATION Capacity (at 1% Excess Air) Gas Inlet Pressure Flame Length (at 1% Excess Air) Flame
More information1470 SERIES HOT AIR GAS BURNER
1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light
More information1466 SERIES COLD AIR GAS/OIL BURNER
CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light wall construction FEATURES
More informationS1 SERIES TECHNICAL DATA INFORMATION PACKET
S1 SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions S1G, S1L, S1LG Technical Data Sheet...3 Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions S1E, S1EG Technical
More informationField proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility
-.9- KINEDIZER LE High capacity low NOx gas burners Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility Lower NOx and less excess air than standard KINEDIZER
More informationKINEMAX. Medium velocity gas or oil burners
KINEMAX Medium velocity gas or oil burners High Temperature Burners - KINEMAX -.- Exit velocities up to 00 km/h (8 m/s) to promote workload heat penetration and better furnace temperature uniformity Operate
More information1070 SERIES ULTRA LOW NO X
CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing
More informationProduct Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT
The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures
More informationDesign and Application Details
Model 400 OVENPAK -II Gas Page 2153 Design and Application Details OVENPAK -II s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are
More informationNorth American 4575 HiRAM
Combustion North American 4575 HiRAM The quality and performance of our Tempest, but bigger. Low NOx burner High Velocity - High Turndown Inputs to 4-25 million Btu/hr Direct Spark or Pilot Lighting Furnace
More informationModel CBLE Boilers HP
Boilers 125-800HP CONTENTS FEATURES AND BENEFITS.....................................................4 True Boiler/Burner/Low NOx Package................................................4 PRODUCT OFFERING.........................................................4
More informationTriOx Triple Air Staged Ultra Low NOx Burner
Triple Air Staged Ultra Low NOx Burner TriOx-1 Edition 09-08 Ultra low NOx emissions of 20 ppm or less Invisiflame mode offers positive UV flame supervision throughout entire operating range for excellent
More informationNOx-Beta Ultra Low NOx Burners
NOx-Beta Ultra Low NOx s February NOx-Beta Features Ultra low NOx without any performance loss Staged air principle no external NOx reducing devices or FGR needed Robust, well engineered construction Cost
More informationDesign and Application Details
LO-NOX Line Burners Page 5803 Design and Application Details Total heat release and LO-NOX Burner footage are normally selected from the tables given in the Series HG Mixing Tube section of the Maxon catalog
More informationPROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET
PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET Technical Data Uncontrolled Emissions Configuration (EG, EL, ELG) 8.4-42.0 MM BTU/H NG; 60-300 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and
More informationNorth American 4485 Tempest SE
Combustion North American 4485 Tempest SE Medium/High Velocity Gas Burner Low NOx gas burner, durable construction and flexible desgin to fit a variety of applications. NPT or BSP air/gas inlets, adjustable
More information1200 SERIES FTR HOT AIR BAFFLE BURNER
CAPABILITIES High release rates with moderate air pressure Good turn down with flame characteristics and direction maintained Stable flames tailored to the job applications can be from highly oxidizing
More informationM SERIES TECHNICAL DATA INFORMATION PACKET
M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data
More information1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER
CAPABILITIES Short, compact, clear and bushy flame Suitable for rich gases and most oils 10% to 300% excess air through burner with rich gaseous fuels and light oils 10% to 100% excess air through burner
More informationBBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction
BBG Gas Beta Burner BBG-1 Edition 02-08 BBG shown with pilot ignition and converging tile options. Designed for low pressure air operation Rugged heavy gauge steel construction Alloy or refractory tile
More informationPROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.
PROFIRE xl Series burners 37.8 TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications. Innovative Technology. Superior performance a technician can trust. The ProFire XL series,
More informationDesign and Application Details
Model 400 OVENPAK Gas Page 2153 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.
More informationINDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS
Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Models MD-25-OG MD-7500-OG December 2012 Copyright 2012 Periflame, Design Guide 113 Industrial Dual-Fuel Burners, 12/01/2012
More informationPROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET
PROFIRE V SERIES TEHNIA DATA INFORMATION PAKET Technical Data Uncontrolled Emissions onfiguration (VG, V, VG) 1.3-16.8 MM BTU/H NG; 9.3-120 GPH #2 OI U listed with choice of NFPA, SD-1, GAP, and FM for
More informationTORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB
TORCH BURNERS LOW, MEDIUM, AND HIPRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB Revision: 0 BULLETIN 325, 32, 327 2 ET 2 RETB DESCRIPTION Torches are made up in three series LowPressure,
More informationBurner Selection Criteria
UNI-RAD Radiant Tube Burners Page 4803 Burner Selection Criteria Combustion Air View Port/Optic Flame Sensor Mount Gas Inlet 3"- 4" Burner Selection The UNI-RAD Burner can be used with various radiant
More informationLow emissions, high performance natural gas burners
-.6- OVENPAK LE Burners Low emissions, high performance natural gas burners Burns any clean fuel gas Operates on low gas supply pressures Provides clean combustion with low NOx and CO levels Compact burner
More informationCOMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners
W 8ST R COMBUSTION A Selas Heat Technology Company Model HDR - RF Manual Addendum (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners With and without Low NOx Flue Gas Recirculation
More informationEclipse Vortometric Burners
Installation Guide 128 8/12/2011 Eclipse Vortometric Burners Models HI and MI Version 4 Copyright Copyright 2007 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal
More informationIMMERSION FIRED HOT WATER BOILER
918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY VLF-CBP (Front Flue) or VLR-CBP (Rear Flue) High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000
More informationUNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE
SERIES 4223, 4323 (API 682 Seal) Section 304 Page 304. TABLE OF CONTENTS Features & Benefits...2 Revolvable Pump Casings...2 Materials of Construction...2 Cutaway View & Pump Features...3 Key...4 Specifications...4
More informationCBLE HP. Boiler Book 05/2017
CBLE 15-800 HP Boiler Book 05/017 CONTENTS FEATURES AND BENEFITS.................................................................3 PRODUCT OFFERING.....................................................................3
More informationECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH
Info 140 11/4/03 ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower
More informationBurner Company OIL GUNS. Bulletin IG-1. Bulletin OG-1A
Burner Company OIL GUNS Bulletin IG-1 Bulletin OG-1A FABER OIL GUNS Faber Burner Company has a complete line of oil guns, ranging from 2.1 to MMBTU/hr. heat input. Any liquid fuel may be burned with either
More informationUNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE
Page 1602.1 TABLE OF CONTENTS Features & Benefits...2 Porting & Sealing...2 Jacketing...2 Revolvable Pump Casings...2 Cutaway View & Pump Features...3 Model Number Key...4 Standard Materials of Construction...4
More informationEclipse Single-Ended Radiant Tube Burners
325 Design Guide 3/8/2011 Eclipse Single-Ended Radiant Tube Burners Models SER450, SER600, & SER800 Version 5 Metallic Ceramic Copyright Copyright 2007 by Eclipse, Inc. All rights reserved worldwide. This
More informationInfo 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes
Info 110 4/98 RatioMatic Burners RM Series version 1.01 50 through 600 Sizes 750 through 2000 Sizes For Ratiomatic Serial Numbers 95-5500 and Above Version 1.01 7/97 Contents 1.0 Operating Parameters &
More informationXID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE
IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner
More informationSpecifications of OPTIMA SLS Burners
1.1.9-4 Low emperature urners - PIM L pecifications of PIM L urners ypical burner data Fuel: natural gas at 60 F with 1000 tu/ft 3 (st) HH - sg = 0.6 (1) ombustion air: 60 F - 21% 2-50% humidity - sg =
More information1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X
1500 SERIES LRGE CPCITY ULTR 2 LOW NO X URNER CPILITIES High release rates with moderate air pressure Good turndown with flame characteristics and direction maintained Stable flames can range from highly
More informationUNI-RAD GAS FIRED RADIANT TUBE BURNER SYSTEM TECHNICAL CATALOG 32M
UNI-RAD GAS FIRED RADIANT TUBE BURNER SYSTEM TECHNICAL CATALOG 32M-02007-01 TABLE OF CONTENTS Product Description... 3 Features and Benefits... 3 Applications... 3 Modes of Operation... 3 Burner Selection
More informationPREMIX TUNNEL BURNERS
FOR ENCLOSED GASAIR COMBUSTION MODEL: 01, 0, 06 Revision: 0 BULLETIN 01, 0, 06 EXPLODED VIEW Pyronic Tunnel Burners will burn any standard fuel gas at mixture pressures ranging from 0.1 to 60 W. C. Exclusive,
More informationLVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1
Gas Limiting Orifice Valve Features Precision machined valve flow piston Rugged cast iron body Replaceable cartridge assembly for LVG 55-5 Straight through valve design; right angle valve option Pressure
More informationUNIVERSAL PRODUCT LINE: STAINLESS STEEL JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE
UNIVERSAL PRODUCT LINE: SERIES 227A, 4227A, 327A, 4327A Section 1702 Page 1702.1 Issue B TABLE OF CONTENTS Features & Benefits...2 Jacketing...2 Relief Valve Configurations...3 Porting & Sealing...3 Revolvable
More informationSITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369
and annular chambers Application Suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -10 to +00 C. Design Orifice plate with annular chambers consisting
More informationUNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE
SERIES 223A, 4223A, 323A, 4323A Page 1302.1 Issue B TABLE OF CONTENTS Features & Benefits...2 Jacketing...2 Relief Valve Configurations...3 Porting & Sealing...3 Revolvable Pump Casings...3 Cutaway View
More informationSV418 Series Bronze Safety Valves ASME Section VIII - NB Certified for Air, Gas, Steam, and Liquid
Safety SV418 Series Bronze Safety Description Spirax Sarco's SV418 safety and relief valve is designed for accuracy and reliability. Engineered for heavy-duty industrial usage. Multiple purpose safety
More informationBBC Multi-fuel Combination Beta Burner
BBC Multi-fuel Combination Beta Burner BBC-1 Edition 11-08 Designed for low pressure air operation Rugged heavy gauge steel construction Converging tile provides higher velocity flames for higher convective
More informationModel CBEX Elite HP
Model CBEX Elite 100-800 HP TABLE OF CONTENTS FEATURES AND BENEFITS.....................................................3 PRODUCT OFFERING.........................................................3 DIMENSIONS
More informationPROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.
PROFIRE D Series burners 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Cleaver-Brooks offers complete boiler
More informationPerformance Selection Data
Series "NP" & "RG" AIRFLO Burners Page 5505 Performance Selection Data Operation in shaded area requires special considerations Optimum Design Area Operation in shaded area requires special considerations
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948
More informationSpecifications of STICKTITE and PILOTPAK Nozzles
-.-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure for STICKTITE and PILOTPK nozzles when fed with an
More informationSurefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual
SF-200 APRIL 10, 2018 Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-32-NG/PG-FD gas
More informationKINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS PRODUCT DESCRIPTION TECHNICAL CATALOG
KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS TECHNICAL CATALOG PRODUCT DESCRIPTION The KINEMAX burner is a nozzle-mixing, medium velocity burner. It provides a stream of hot combustion gases that promote
More informationD SERIES BURNERS 4.2 TO 42.0 MMBTU/HR
D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Industrial Combustion offers complete boiler
More informationNorth American Combustion Burners
Combustion North American Combustion Burners 4441 North American Tempest High Velocity Gas Burner Jet action burner offering superior recirculation Slotted tile produces exceptional temperature uniformity
More informationP200 Pressure Regulator
P200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P202 has internal relief valve for overpressure protection The P200 series pressure regulator is a manual, direct acting,
More informationECLIPSE TURBO BLOWERS SERIES SMJ
Bulletin /0 ECLIPSE TURBO BLOWERS SERIES SMJ High efficiency Heavy gauge steel base and housing Aluminum impellers balanced statically and dynamically Matching air fi lters available Changeable outlet
More information2.0 Burner Operating Parameters and Requirements
ECLIPSE INFORMATION GUIDE Silicon Carbide Radiant Auto-Recupes Info 322 2/99 WARNING Handle silicon carbide tubes carefully. Do not drop them or hammer on them. Although they feature excellent mechanical
More informationModels. Save This Manual For Future Reference. International Comfort Products Corporation (USA) Lewisburg, TN USA LP1 5/16/
Models NTC7050BFG / GNL050NG NTC7075BFG / GNL075NG NTC700BHG / GNL00N6G NTC75BKG / GNL5N0G NDC7050BFG / GDL050NG NDC7075BFG / GDL075NG NDC700BHG / GDL00N6G NDC75BKG / GDL5N0G Manufactured by: International
More informationNorth American Combustion Burners
Combustion North American Combustion Burners 4441 North American Tempest High Velocity Gas Burner Jet action burner offering superior recirculation Slotted tile produces exceptional temperature uniformity
More information97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel
97311T Designed for complete automatic operation of the entire Burner System, the S&J 97311T Enclosed Flare and Touch Screen Control Panel is specifically designed to operate efficiently with low BTU anaerobic
More information420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS
MDEL C/C S IR R STEM LIHT IL TMIZIN FRCED DRFT BURNERS Power Flame s Versatile High Performance ir or Steam tomizing Light il Burner djustable Premix Firing Head Produces optimum fuel/air mixture within
More informationSpecifications of STICKTITE and PILOTPAK Nozzles
Low Temperature urners - STICKTITE and PILOTPK Nozzles 1-1.1-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure
More informationMAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS
LOW EMIION, HIGH PERFORMANCE GA BURNER TECHNICAL CATALOG Fuel and air pressures for the burner are balanced (always equal). This unique design provides simple operation and adjustment throughout the operational
More informationP200 Pressure Regulator
P200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P202 has internal relief valve for overpressure protection The P200 series pressure regulator is a manual, direct acting,
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000
More informationLANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM
LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM Part 1. General 1.01 Description A. This section describes a candlestick flare system for the combustion of landfill gases. The flare system must be of
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTUH
More informationFlame Arrestor Design and Application Data
Flame Arrestor Design and Application Data Please print it, fill it out and fax it to 1-352-493-2111 or scan & email to info@paradoxintellectual.com Items marked with an asterisk (*) are required fields.
More informationSeries Low Pressure Steam Heating Boiler Safety Valves
12-200 Series Low Pressure Steam Heating Boiler Safety Valves Section IV Heating Boilers Medium capacity safety valves protect ASME Section IV low pressure steam heating boilers. Cast bronze, full nozzle
More informationSureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION
SF-200 OCTOBER 10, 2016 SureFire II TM Pilot Forced Draught Gas Pilot type SP-32-xx-FD Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-32-xx-FD gas pilot
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000
More informationP200 Pressure Regulator
P200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P202 has internal relief valve for overpressure protection The P200 series pressure regulator is a manual, direct acting,
More informationD I V I S I O N O F M A R S H B E L L O F R A M
PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil
More informationFeatures Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design
97311 The S&J 97311 Enclosed burner incinerates harmful emissions from waste gas streams. Typical applications include fermentation off gas piping systems such as anaerobic digesters or landfill gas. This
More informationClean Burning Technology
The MTC Clean and Superclean burners were developed to provide the Well testing market with a compact, lightweight and practical clean up and separated oil burning solution with a complete combustion system
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG)
MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) VHF-ANP / VHF-ANE (BECKETT NX) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250
More informationLow Temperature Burners - STICKTITE and PILOTPAK Nozzles
Low Temperature Burners - STICKTITE and PILOTPK Nozzles STICKTITE & PILOTPK Flame retention nozzles -.- For open-port firing or open environment firing Provides positive flame retention and stable clean
More informationSTEAM TRAPS. Inverted Bucket Steam Traps (continued) Series B. Dimensions in. (mm)
X X X X X X X X X X X X X X TEMP. PRESS. PRESS OFF TEMP. PRESS. PRESS OFF DATE CODE Hoffman ITT DATE CODE Hoffman ITT STEAM TRAPS Inverted Bucket (continued) 3 Available in sizes 3 4" and 1" NPT and BSPT
More informationSECTION Pressure & Temperature Control
16 Pressure & Temperature Control ARMSTRONG PRODUCT CATALOGUE 70 Pressure Reducing s Pressure Reducing s Armstrong pressure reducing valves (PRVs) and temperature regulators help you manage steam, air
More informationSureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual
SF-500 September 10, 2018 SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-48-NG/PG-ND gas pilot
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED BOY FURNACE SPECIFICATIS MODEL NO. HEATING CAPACITY TLF1M087C942SA TLR1M087C942SA High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire High Fire Med-High Fire TLF1M087D9V5SA [6] TLR1M087D9V5SA
More informationMaxon Shut-Off and Vent Valves General Purpose
Maxon Shut-Off and Vent Valves General Purpose Bulletin 60 " Series 808 position "TO" 2" Series 00-CP position L with stainless steel body " Series STO-ACP position R Electrically actuated valves shut
More informationP95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients
PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. VH8FA119P60B VH8FA119T60B (BECKETT AFG) HEATING CAPACITY High Fire * Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 OUTPUT BTUH 1 132,000 119,000 101,000 SEASONAL EFFICIENCY
More information