Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Size: px
Start display at page:

Download "Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT"

Transcription

1 The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures or high altitude applications. LNVG gas burners, burn gas under a controlled gas/air pressure mix. Gas is emitted from jets surrounding the air stream, producing a turbulent mixture which burns quietly and efficiently. Oil firing features a high pressure atomizing design using simplex nozzles and a separately driven, two stage remote oil pump. Consistent fuel/ air ratio is maintained regardless of firing rate. GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT Product Information Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 Flue gas recirculation (FGR) is drawn through the burner blower assembly properly sized for the required NOx emission levels. An FGR control valve is positioned by the FGR system to provide FGR at all firing rates. An FGR shutoff valve is placed in the FGR line as part of a safety system. This shutoff valve prevents combustible gases from being drawn into the boiler furnace prior to pilot and main flame ignition. Proper operation of this system is proven by three (3) electrical safety interlocks. The system is equipped with ANSI flanges to allow easy installation into the FGR piping. Listed by Underwriters Laboratory. CSD-1, GE Gap, F.M. and other regulatory agency control options are available. Every burner is assembled, wired and tested at the factory. A. CONTROLS 1. Burner mounted control panel /1/60 control circuit 3. Motor starter(s). Panel signal lights (See Note 3) 5. Full Modulation firing 6. Fuel changeover switch (combination gas/oil models) 7. Flame safeguard controls 8. Combustion air proving switch 9. Ignition transformer 10. UV Scanner B. OIL SYSTEM 1. Two stage fuel oil pump, separately driven 2. Simplex oil nozzle 3. Oil solenoid valve. S.S.O. oil solenoid valve 5. Oil metering valve C. MAIN GAS SYSTEM (See Note 1) 1. Butterfly rate control valve 2. Safety shutoff valve(s) per code requirements 3. Gas shutoff cocks (2). Main gas regulator D. GAS PILOT SYSTEM 1. Gas-electric interrupted pilot 2. Shutoff cock 3. Separate pilot regulator and valve F. OPTIONAL EQUIPMENT 1. Control circuit transformer 2. Inverted housing arrangement 3. Totally enclosed and 50 cycle motors. Remote mount control panel NOTES 1. All main gas line valves and accessories upstream of butterfly valve are shipped loose 2. Standard motor voltages are 115/ /1/60 3. Signal lights: Power On, Main Fuel, Ignition, and Flame Failure ORDERING INFORMATION (SPECIFY) 1. Blower motor voltage, phase and cycle 2. Control circuit voltage (120/1/60 is standard) 3. Burner model and actual firing rate. Flame safeguard control 5. Requirements for special state or local codes in detail 6. Insurance requirements 7. Available gas pressure 8. Firing vessel and furnace pressure Type of fuel determines the model designation Model Fuel LNVG Gas LNVLG No. 2 Oil / Gas E. OTHER EQUIPMENT rpm blower motor 2. Burner mounting flange IC /08 Page 1 of 2

2 Product Information BURNER SIZE CAPACITIES & SPECIFICATIONS GAS INPUT (Mbtu/hr) (See Note 1) 1,300 1,500 1,700 2,000 2,100 2,500 OIL INPUT (U.S. GPH) (See Note 2) BOILER 80% EFF. (See Note 3) GAS MANIFOLD PRESSURE ( w.c.) (See Note ) BLOWER MOTOR HP (See Note 5) 3/ 3/ 3/ 3/ 3/ 3/ OIL METERING UNIT MOTOR HP 1/3 1/3 1/3 1/3 1/3 1/3 F.G.R. LINE PIPING SIZE (in.) APPROX. SHIPPING WEIGHT (lbs.) Notes: 1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity 2. Oil input based on No. 2 oil at 10,000 Btu/gal. 3. Boiler overall efficiency of 80% estimated. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furnace pressure. 5. Blower wheel and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications, consult factory 1/" NPT 16 1/ R15 3/ 12 1/8 8 1/ 12 3/ 11 3/8 10 7/8 3 3/ OIL RETURN OUTLET 15 7/8 29 7/ /8 27 3/ 13 3/8 18 1/2 18 1/ 11 GAS PILOT () HOLES 3/" DIA. ON 11 1/" DIA. B.C. X /8 5 1/ / 3 7/ / 8 5/8 (8) HOLES 3/" DIA. ON 7 1/2" DIA. B.C. F.G.R. 25 3/8 3 5/8 13 3/8 NOTE 1 - DIMENSIONS ARE FOR REFERENCE ONLY. DIMENSIONS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. MAIN GAS 1-1/2" NPT 9 7/8 11 1/ DIMENSION DIAGRAM GAS/OIL W/ TOP ELEC. ENCL. LNV-SERIES, MODEL LNVLG, SIZE Page 2 of 2 IC /08

3 The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures or high altitude applications. LNVG gas burners, burn gas under a controlled gas/air pressure mix. Gas is emitted from jets surrounding the air stream, producing a turbulent mixture which burns quietly and efficiently. Oil firing features a high pressure atomizing design using return flow nozzles and a separately driven, two stage remote oil pump. Consistent fuel/ air ratio is maintained regardless of firing rate. GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT Product Information Model: LNVG, LNVLG Burner Sizes: 30, 3, 35, 0, 2, 5, 50 Flue gas recirculation (FGR) is drawn through the burner blower assembly properly sized for the required NOx emission levels. An FGR control valve is positioned by the FGR system to provide FGR at all firing rates. An FGR shutoff valve is placed in the FGR line as part of a safety system. This shutoff valve prevents combustible gases from being drawn into the boiler furnace prior to pilot and main flame ignition. Proper operation of this system is proven by three (3) electrical safety interlocks. The system is equipped with ANSI flanges to allow easy installation into the FGR piping. Listed by Underwriters Laboratory. CSD-1, GE Gap, F.M. and other regulatory agency control options are available. Every burner is assembled, wired and tested at the factory. A. CONTROLS 1. Burner mounted control panel /1/60 control circuit 3. Motor starter(s). Panel signal lights (See Note 3) 5. Full Modulation firing 6. Fuel changeover switch (combination gas/oil models) 7. Flame safeguard controls 8. Combustion air proving switch 9. Ignition transformer 10. UV scanner B. OIL SYSTEM 1. Two stage fuel oil pump, separately driven 2. Return flow oil nozzle 3. Oil solenoid valve. S.S.O. oil solenoid valve 5. Oil metering valve C. MAIN GAS SYSTEM (See Note 1) 1. Butterfly rate control valve 2. Safety shutoff valve(s) per code requirements 3. Gas shutoff cocks (2). Main gas regulator D. GAS PILOT SYSTEM 1. Gas-electric interrupted pilot 2. Shutoff cock 3. Separate pilot regulator and valve E. OTHER EQUIPMENT rpm blower motor 2. Burner mounting flange F. OPTIONAL EQUIPMENT 1. Control circuit transformer 2. Inverted housing arrangement 3. Totally enclosed and 50 cycle motors. Remote mount control panel NOTES 1. All main gas line valves and accessories upstream of butterfly valve are shipped loose 2. Standard motor voltages are 115/ /1/60 3. Signal lights: Power On, Main Fuel, Ignition, and Flame Failure ORDERING INFORMATION (SPECIFY) 1. Blower motor voltage, phase and cycle 2. Control circuit voltage (120/1/60 is standard) 3. Burner model and actual firing rate. Flame safeguard control 5. Requirements for special state or local codes in detail 6. Insurance requirements 7. Available gas pressure 8. Firing vessel and furnace pressure Type of fuel determines the model designation Model Fuel LNVG Gas LNVLG No. 2 Oil / Gas IC /08 Page 1 of 2

4 Product Information BURNER SIZE CAPACITIES & SPECIFICATIONS GAS INPUT (Mbtu/hr) (See Note 1) 3,000 3,00 3,500,000,200,500 5,000 OIL INPUT (U.S. GPH) (See Note 2) BOILER 80% EFF. (See Note 3) GAS MANIFOLD PRESSURE ( w.c.) (See Note ) BLOWER MOTOR HP (See Note 5) OIL METERING UNIT MOTOR HP 1/3 1/3 1/3 1/3 1/3 1/3 1/3 F.G.R. LINE PIPING SIZE (in.) APPROX. SHIPPING WEIGHT (lbs.) Notes: 1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity 2. Oil input based on No. 2 oil at 10,000 Btu/gal. 3. Boiler overall efficiency of 80% estimated. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furnace pressure. 5. Blower wheel and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications, consult factory 1/" NPT R15 3/ 13 1/ /8 9 3/ 3 3/ OIL RETURN OUTLET 17 1/2 3 5/8 30 5/8 1 7/8 27 3/ 12 7/8 23 1/ 21 1/8 GAS PILOT 12 3/8 () HOLES 3/" DIA. ON 13 1/" DIA. B.C. X /8 6 1/8 5 1/8 5 1/ 1 1/ / (8) HOLES 3/" DIA. ON 7 1/2" DIA. B.C. F.G.R. 29 7/8 15 MAIN GAS 2" NPT 10 1/ 11 3/ NOTE 1 - DIMENSIONS ARE FOR REFERENCE ONLY. DIMENSIONS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. DIMENSION DIAGRAM GAS/OIL W/ TOP ELEC. ENCL. LNV-SERIES, MODEL LNVLG, SIZE Page 2 of 2 IC /08

5 The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures or high altitude applications. LNVG gas burners, burn gas under a controlled gas/air pressure mix. Gas is emitted from jets surrounding the air stream, producing a turbulent mixture which burns quietly and efficiently. Oil firing features a high pressure atomizing design using return flow nozzles and a separately driven, two stage remote oil pump. Consistent fuel/ air ratio is maintained regardless of firing rate. GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT Product Information Model: LNVG, LNVLG Burner Sizes: 5, 55, 60, 63, 70, 80, 8, 90 Flue gas recirculation (FGR) is drawn through the burner blower assembly properly sized for the required NOx emission levels. An FGR control valve is positioned by the FGR system to provide FGR at all firing rates. An FGR shutoff valve is placed in the FGR line as part of a safety system. This shutoff valve prevents combustible gases from being drawn into the boiler furnace prior to pilot and main flame ignition. Proper operation of this system is proven by three (3) electrical safety interlocks. The system is equipped with ANSI flanges to allow easy installation into the FGR piping. Listed by Underwriters Laboratory. CSD-1, GE Gap, F.M. and other regulatory agency control options are available. Every burner is assembled, wired and tested at the factory. A. CONTROLS 1. Burner mounted control panel /1/60 control circuit 3. Motor starter(s). Panel signal lights (See Note 3) 5. Full Modulation firing 6. Fuel changeover switch (combination gas/oil models) 7. Flame safeguard controls 8. Combustion air proving switch 9. Ignition transformer 10. UV scanner B. OIL SYSTEM 1. Two stage fuel oil pump, separately driven 3. Return flow oil nozzle 3. Oil solenoid valve. S.S.O. oil solenoid valve 5. Oil metering valve C. MAIN GAS SYSTEM (See Note 1) 1. Butterfly rate control valve 2. Safety shutoff valve(s) per code requirements 3. Gas shutoff cocks (2). Main gas regulator D. GAS PILOT SYSTEM 1. Gas-electric interrupted pilot 2. Shutoff cock 3. Separate pilot regulator and valve F. OPTIONAL EQUIPMENT 1. Control circuit transformer 2. Inverted housing arrangement 3. Totally enclosed and 50 cycle motors. Remote mount control panel NOTES 1. All main gas line valves and accessories upstream of butterfly valve are shipped loose 2. Standard motor voltages are /60/3/60 3. Signal lights: Power On, Main Fuel, Ignition, and Flame Failure ORDERING INFORMATION (SPECIFY) 1. Blower motor voltage, phase and cycle 2. Control circuit voltage (120/1/60 is standard) 3. Burner model and actual firing rate. Flame safeguard control 5. Requirements for special state or local codes in detail 6. Insurance requirements 7. Available gas pressure 8. Firing vessel and furnace pressure Type of fuel determines the model designation Model Fuel LNVG Gas LNVLG No. 2 Oil / Gas E. OTHER EQUIPMENT rpm blower motor 2. Burner mounting flange IC /08 Page 1 of 2

6 Product Information BURNER SIZE CAPACITIES & SPECIFICATIONS GAS INPUT (Mbtu/hr) (See Note 1) 5,00 5,500 6,000 6,300 7,000 8,000 8,00 9,000 OIL INPUT (U.S. GPH) (See Note 2) BOILER 80% EFF. (See Note 3) GAS MANIFOLD PRESSURE ( w.c.) (See Note ) BLOWER MOTOR HP (See Note 5) /2 7 1/2 7 1/2 7 1/2 OIL METERING UNIT MOTOR HP 3/ 3/ 3/ 3/ 3/ 3/ 1 1 F.G.R. LINE PIPING SIZE (in.) APPROX. SHIPPING WEIGHT (lbs.) Notes: 1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity 2. Oil input based on No. 2 oil at 10,000 Btu/gal. 3. Boiler overall efficiency of 80% estimated. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furnace pressure. 5. Blower wheel and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications, 3 1/8 R15 3/ 1 Ø11 1/2 16 3/ 1 3/8 13 7/8 1 1/2 OIL RETURN OUTLET 19 3/ 0 1/ 36 1/ 16 1/8 31 5/8 15 3/8 28 7/8 GAS PILOT 1/2" NPT 25 3/8 15 3/8 () HOLES 3/" DIA. ON 15 1/" DIA. B.C. X /8 7 7/8 18 5/8 7 7/ / 1 5/8 (8) HOLES 3/" DIA. ON 7 1/2" DIA. B.C. F.G.R. 36 7/8 3 3/ 17 1/2 MAIN GAS 2-1/2" NPT 11 1/2 15 1/ NOTE 1 - DIMENSIONS ARE FOR REFERENCE ONLY. DIMENSIONS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. DIMENSION DIAGRAM GAS/OIL W/ TOP ELEC. ENCL. LNV-SERIES, MODEL LNVLG, SIZE Page 2 of 2 IC /08

7 The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures or high altitude applications. LNVG gas burners, burn gas under a controlled gas/air pressure mix. Gas is emitted from jets surrounding the air stream, producing a turbulent mixture which burns quietly and efficiently. Oil firing features a high pressure atomizing design using return flow nozzles and a separately driven, two stage remote oil pump. Consistent fuel/ air ratio is maintained regardless of firing rate. GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT Product Information Model: LNVG, LNVLG Burner Sizes: 100, 105, 110, 120, 126, 17 Flue gas recirculation (FGR) is drawn through the burner blower assembly properly sized for the required NOx emission levels. An FGR control valve is positioned by the FGR system to provide FGR at all firing rates. An FGR shutoff valve is placed in the FGR line as part of a safety system. This shutoff valve prevents combustible gases from being drawn into the boiler furnace prior to pilot and main flame ignition. Proper operation of this system is proven by three (3) electrical safety interlocks. The system is equipped with ANSI flanges to allow easy installation into the FGR piping. Listed by Underwriters Laboratory. CSD-1, GE Gap, F.M. and other regulatory agency control options are available. Every burner is assembled, wired and tested at the factory. A. CONTROLS 1. Burner mounted control panel /1/60 control circuit 3. Motor starter(s). Panel signal lights (See Note 3) 5. Full Modulation firing 6. Fuel changeover switch (combination gas/oil models) 7. Flame safeguard controls 8. Combustion air proving switch 9. Ignition transformer 10. UV scanner B. OIL SYSTEM 1. Two stage fuel oil pump, separately driven 3. Return flow oil nozzle 3. Oil solenoid valve. S.S.O. oil solenoid valve 5. Oil metering valve C. MAIN GAS SYSTEM (See Note 1) 1. Butterfly rate control valve 2. Safety shutoff valve(s) per code requirements 3. Gas shutoff cocks (2). Main gas regulator D. GAS PILOT SYSTEM 1. Gas-electric interrupted pilot 2. Shutoff cock 3. Separate pilot regulator and valve E. OTHER EQUIPMENT rpm blower motor 2. Burner mounting flange F. OPTIONAL EQUIPMENT 1. Control circuit transformer 2. Inverted housing arrangement 3. Totally enclosed and 50 cycle motors. Remote mount control panel NOTES 1. All main gas line valves and accessories upstream of butterfly valve are shipped loose 2. Standard motor voltages are /60/3/60 3. Signal lights: Power On, Main Fuel, Ignition, and Flame Failure ORDERING INFORMATION (SPECIFY) 1. Blower motor voltage, phase and cycle 2. Control circuit voltage (120/1/60 is standard) 3. Burner model and actual firing rate. Flame safeguard control 5. Requirements for special state or local codes in detail 6. Insurance requirements 7. Available gas pressure 8. Firing vessel and furnace pressure Type of fuel determines the model designation Model Fuel LNVG Gas LNVLG No. 2 Oil / Gas IC /08 Page 1 of 2

8 Product Information BURNER SIZE CAPACITIES & SPECIFICATIONS GAS INPUT (Mbtu/hr) (See Note 1) 10,000 10,500 11,000 12,000 12,600 1,700 OIL INPUT (U.S. GPH) (See Note 2) BOILER 80% EFF. (See Note 3) GAS MANIFOLD PRESSURE ( w.c.) (See Note ) TBD BLOWER MOTOR HP (See Note 5) OIL METERING UNIT MOTOR HP 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 F.G.R. LINE PIPING SIZE (in.) APPROX. SHIPPING WEIGHT (lbs.) Notes: 1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity 2. Oil input based on No. 2 oil at 10,000 Btu/gal. 3. Boiler overall efficiency of 80% estimated. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furnace pressure. 5. Blower wheel and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications, consult factory 39 7/8 R 20 1/ /8 Ø13 5/8 17 1/2 1 1/2 13 7/8 OIL RETURN OUTLET 22 5/8 7 5/8 2 5/8 35 1/8 16 1/8 31 5/8 15 3/8 GAS PILOT 1/2" NPT 30 1/ 15 3/8 () HOLES 3/" DIA. ON 15-3/8" DIA. B.C. X /8 19 3/8 7 7/8 12 3/8 1 5/8 Ø13 1/2 (8) HOLES 15/16" DIA. ON 11 3/" DIA. B.C. F.G.R. 2 3/ 21 1/2 NOTE 1 - DIMENSIONS ARE FOR REFERENCE ONLY. DIMENSIONS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. MAIN GAS 2-1/2" NPT 11 1/2 15 1/ DIMENSION DIAGRAM GAS/OIL W/ TOP ELEC. ENCL. LNV-SERIES, MODEL LNVLG, SIZE Page 2 of 2 IC /08

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,

More information

M SERIES TECHNICAL DATA INFORMATION PACKET

M SERIES TECHNICAL DATA INFORMATION PACKET M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical

More information

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET Technical Data Uncontrolled Emissions Configuration (EG, EL, ELG) 8.4-42.0 MM BTU/H NG; 60-300 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and

More information

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET PROFIRE V SERIES TEHNIA DATA INFORMATION PAKET Technical Data Uncontrolled Emissions onfiguration (VG, V, VG) 1.3-16.8 MM BTU/H NG; 9.3-120 GPH #2 OI U listed with choice of NFPA, SD-1, GAP, and FM for

More information

S1 SERIES TECHNICAL DATA INFORMATION PACKET

S1 SERIES TECHNICAL DATA INFORMATION PACKET S1 SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions S1G, S1L, S1LG Technical Data Sheet...3 Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions S1E, S1EG Technical

More information

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications. PROFIRE xl Series burners 37.8 TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications. Innovative Technology. Superior performance a technician can trust. The ProFire XL series,

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948

More information

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF

More information

XL/LNXL SERIES. Installation, Operation, and Service Manual for Vertical Configuration

XL/LNXL SERIES. Installation, Operation, and Service Manual for Vertical Configuration XL/LNXL SERIES Installation, Operation, and Service Manual for Vertical Configuration! WARNING DANGER ONLY FACTORY AUTHORIZED BURNER SERVICE PERSONNEL SHOULD START UP, ADJUST, OR SERVICE THIS EQUIPMENT

More information

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. PROFIRE D Series burners 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Cleaver-Brooks offers complete boiler

More information

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner

More information

MULTIFIRE. High temperature dual fuel burner

MULTIFIRE. High temperature dual fuel burner MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,

More information

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Industrial Combustion offers complete boiler

More information

IMMERSION FIRED HOT WATER BOILER

IMMERSION FIRED HOT WATER BOILER 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series

More information

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign 3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot

More information

KINEMAX. Medium velocity gas or oil burners

KINEMAX. Medium velocity gas or oil burners KINEMAX Medium velocity gas or oil burners High Temperature Burners - KINEMAX -.- Exit velocities up to 00 km/h (8 m/s) to promote workload heat penetration and better furnace temperature uniformity Operate

More information

1070 SERIES ULTRA LOW NO X

1070 SERIES ULTRA LOW NO X CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing

More information

Eclipse Vortometric Burners Series HI

Eclipse Vortometric Burners Series HI Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas)

More information

Model HDS and HDSX Burner

Model HDS and HDSX Burner Price: $50.00 US $75.00 Canadian Webster Engineering & Manufacturing Co., L.L.C. 619 Industrial Road, Winfield, KS 67156 Installation, Startup, Operation and Maintenance Manual Model HDS and HDSX Burner

More information

M/SERIES. Installation, Operation, Service, and Parts Manual

M/SERIES. Installation, Operation, Service, and Parts Manual M/SERIES Installation, Operation, Service, and Parts Manual! WARNING DANGER ONLY FACTORY AUTHORIZED BURNER SERVICE PERSONNEL SHOULD START UP, ADJUST, OR SER- VICE THIS EQUIPMENT IC-993 09/10 M SERIES

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire

More information

BOILER RATINGS. Net Ratings Oil Gas

BOILER RATINGS. Net Ratings Oil Gas POWER BURNER Series TC II Large Commercial s -, Assembled Block or Individual Sections Forced Draft ing Power s - Oil, Gas, Gas/Oil or Hot s Optional Tankless Coils Increased Efficiencies Oil Input GPH

More information

Model CBEX Elite HP

Model CBEX Elite HP Model CBEX Elite 100-800 HP TABLE OF CONTENTS FEATURES AND BENEFITS.....................................................3 PRODUCT OFFERING.........................................................3 DIMENSIONS

More information

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility -.9- KINEDIZER LE High capacity low NOx gas burners Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility Lower NOx and less excess air than standard KINEDIZER

More information

D/LND SERIES. Installation, Operation, and Service Manual

D/LND SERIES. Installation, Operation, and Service Manual D/LND SERIES Installation, Operation, and Service Manual! WARNING DANGER ONLY FACTORY AUTHORIZED BURNER SERVICE PERSONNEL SHOULD START UP, ADJUST, OR SER- VICE THIS EQUIPMENT IC-790 10/10 D/LND SERIES

More information

VALUPAK. Packaged gas burners

VALUPAK. Packaged gas burners VALUPAK Packaged gas burners 1-1.5-1 E - i - 11/14 High turndown. Available in 6 sizes. Capacities: 0.007 MBtu/hr - 4 MBtu/hr. Stable and clean combustion. Suitable for UV scanner and flame rod. Natural

More information

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design 97311 The S&J 97311 Enclosed burner incinerates harmful emissions from waste gas streams. Typical applications include fermentation off gas piping systems such as anaerobic digesters or landfill gas. This

More information

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel 97311T Designed for complete automatic operation of the entire Burner System, the S&J 97311T Enclosed Flare and Touch Screen Control Panel is specifically designed to operate efficiently with low BTU anaerobic

More information

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

X4 Installation and Operation Manual - POWER FLAME INCORPORATED 7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice

More information

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners W 8ST R COMBUSTION A Selas Heat Technology Company Model HDR - RF Manual Addendum (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners With and without Low NOx Flue Gas Recirculation

More information

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750 Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact

More information

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000 Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged

More information

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes Info 110 4/98 RatioMatic Burners RM Series version 1.01 50 through 600 Sizes 750 through 2000 Sizes For Ratiomatic Serial Numbers 95-5500 and Above Version 1.01 7/97 Contents 1.0 Operating Parameters &

More information

1470 SERIES HOT AIR GAS BURNER

1470 SERIES HOT AIR GAS BURNER 1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles Low Temperature Burners - STICKTITE and PILOTPK Nozzles STICKTITE & PILOTPK Flame retention nozzles -.- For open-port firing or open environment firing Provides positive flame retention and stable clean

More information

Doing more for clean environment and energy saving

Doing more for clean environment and energy saving Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one

More information

Data 330-3 9/15/07 Eclipse ImmersoJet Burners Model 3 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr)

More information

PREMIX TUNNEL BURNERS

PREMIX TUNNEL BURNERS FOR ENCLOSED GASAIR COMBUSTION MODEL: 01, 0, 06 Revision: 0 BULLETIN 01, 0, 06 EXPLODED VIEW Pyronic Tunnel Burners will burn any standard fuel gas at mixture pressures ranging from 0.1 to 60 W. C. Exclusive,

More information

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies: Airejet Low NOx Coal Burner Unique low NO X coal burner with center air jet for use with overfire air (OFA) systems. Sleeve Damper Actuator Core Air Inlet Duct and Damper Pitot Grid Outer Spin Vanes Inner

More information

FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP

FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP Features of the FD68 Series RUGGED INDUSTRIAL DESIGN SUPERIOR HOUSING Cylindrical windbox design provides

More information

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM Part 1. General 1.01 Description A. This section describes a candlestick flare system for the combustion of landfill gases. The flare system must be of

More information

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS MDEL C/C S IR R STEM LIHT IL TMIZIN FRCED DRFT BURNERS Power Flame s Versatile High Performance ir or Steam tomizing Light il Burner djustable Premix Firing Head Produces optimum fuel/air mixture within

More information

Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A.

Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A. Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A. 2001 South 21st Street Phone 620-421-0480 Parsons, KS 67357 FAX 620-421-0948 Web Site: http://www.powerflame.com E-Mail: CSD@powerflame.com

More information

Oil, gas and dual fuel burners. Burner series

Oil, gas and dual fuel burners. Burner series Oil, gas and dual fuel burners Burner series 350...450 Group 4B Capacity 700-5500 kw 1 2 Table of contents General 5 Light fuel oil burners 6 Dimensions and PI diagram 6 Technical data 7 Capacity/back

More information

1466 SERIES COLD AIR GAS/OIL BURNER

1466 SERIES COLD AIR GAS/OIL BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light wall construction FEATURES

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Product Bulletin Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve The G196 Series valves use the reliable valve body and magnetic operators from

More information

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING HIGH EFFICIENCY BURNER ASSEMBLY HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING This manual must be read in its entirety before installation of this burner. Installation must be performed by a

More information

Economite RE Series. Power Gas Burners. MADE in the USA

Economite RE Series. Power Gas Burners. MADE in the USA Economite RE Series MADE in the USA Economite RE 4000 Series MADE in the USA Midco s Economite Family of Burners Backed by 60 Years of Experience 4.00" 6.00" 12.00" RE 4400DS 9.00" 15.75" 20.50" 8.44"

More information

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB TORCH BURNERS LOW, MEDIUM, AND HIPRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB Revision: 0 BULLETIN 325, 32, 327 2 ET 2 RETB DESCRIPTION Torches are made up in three series LowPressure,

More information

Model CBLE Boilers HP

Model CBLE Boilers HP Boilers 125-800HP CONTENTS FEATURES AND BENEFITS.....................................................4 True Boiler/Burner/Low NOx Package................................................4 PRODUCT OFFERING.........................................................4

More information

Converting to Natural Gas for MATs Compliance August 7, 2014

Converting to Natural Gas for MATs Compliance August 7, 2014 Converting to Natural Gas for MATs Compliance August 7, 2014 Presented by R. Gifford Broderick CCA Combustion Systems a Division of Peerless Mfg. 884 Main Street, Monroe, Connecticut 06468 Tel: (203) 268-3139

More information

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH Info 140 11/4/03 ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower

More information

Table Of Contents. Profire M Burner. Gas, #2-5 Oil, #2-6 Oil, or Combination. Installation Operation Maintenance Parts

Table Of Contents. Profire M Burner. Gas, #2-5 Oil, #2-6 Oil, or Combination. Installation Operation Maintenance Parts Table Of Contents Profire M Burner Gas, #2-5 Oil, #2-6 Oil, or Combination Installation Operation Maintenance Parts Manual Part No. 750-207 04/2009 M/SERIES Installation, Operation, Service, and Parts

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK -II Gas Page 2153 Design and Application Details OVENPAK -II s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are

More information

Data /1/07 Eclipse RatioAir Burners Model RA0040

Data /1/07 Eclipse RatioAir Burners Model RA0040 Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged Minimum input, () Lower inputs may be achieved. Contact factory. Main Gas Inlet

More information

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles Low Temperature urners - STICKTITE and PILOTPK Nozzles 1-1.1-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure

More information

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER CAPABILITIES Short, compact, clear and bushy flame Suitable for rich gases and most oils 10% to 300% excess air through burner with rich gaseous fuels and light oils 10% to 100% excess air through burner

More information

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Models MD-25-OG MD-7500-OG December 2012 Copyright 2012 Periflame, Design Guide 113 Industrial Dual-Fuel Burners, 12/01/2012

More information

Start-up Instructions

Start-up Instructions RadMax Burners Page 400-S- Start-up Instructions Read complete instructions before proceeding and familiarize yourself with all the system s equipment and components. Verify that all equipment has been

More information

North American 4575 HiRAM

North American 4575 HiRAM Combustion North American 4575 HiRAM The quality and performance of our Tempest, but bigger. Low NOx burner High Velocity - High Turndown Inputs to 4-25 million Btu/hr Direct Spark or Pilot Lighting Furnace

More information

Pilot Capacities/Specifications

Pilot Capacities/Specifications s Page 9505 Capacities/Specifications Maxon offers a wide range of gas pilots to meet the specific needs of each of its burner product lines. In most cases, the appropriate burner catalog section will

More information

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD. I EQUIPMENT : GAS/OIL FIRED INDIRECTLY HEATED ROTARY REACTOR. Technical Data : 01. Type : Indirectly heated. 02. Purpose : Heating / Drying / Calcination etc. 03. Feed Size : 0 25mm. 04. Feeder System

More information

KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS PRODUCT DESCRIPTION TECHNICAL CATALOG

KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS PRODUCT DESCRIPTION TECHNICAL CATALOG KINEMAX MEDIUM VELOCITY GAS OR OIL BURNERS TECHNICAL CATALOG PRODUCT DESCRIPTION The KINEMAX burner is a nozzle-mixing, medium velocity burner. It provides a stream of hot combustion gases that promote

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

Specifications of MAXON VALUPAK burners for 50 Hz operation

Specifications of MAXON VALUPAK burners for 50 Hz operation 1-1.5-7 Specifications of MAXON VALUPAK burners for 50 Hz operation Capacity data in kw Gross heating value = 10.9 kwh/m 3 (st), d = 0.6. All figures are for balanced - 0 mbar - duct pressure VALUPAK size

More information

VALUPAK. Packaged gas burners

VALUPAK. Packaged gas burners VALUPAK Packaged gas burners Low Temperature Burners - VALUPAK 1-1.5-1 High turndown. Available in 6 sizes. Capacities: 2 kw -1124 kw (HHV). Stable and clean combustion. Suitable for UV scanner and flame

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

7. SERVICING AND COMPONENT ADJUSTMENTS

7. SERVICING AND COMPONENT ADJUSTMENTS 7. SERVICING AND COMPONENT ADJUSTMENTS General Information on Internal Bypass Oil Systems 1. The system is designed to use 300 PSI pressure at the nozzle inlet at low and high fire (and throughout the

More information

Design and Application Details

Design and Application Details LO-NOX Line Burners Page 5803 Design and Application Details Total heat release and LO-NOX Burner footage are normally selected from the tables given in the Series HG Mixing Tube section of the Maxon catalog

More information

Maxon Shut-Off and Vent Valves General Purpose

Maxon Shut-Off and Vent Valves General Purpose Maxon Shut-Off and Vent Valves General Purpose Bulletin 60 " Series 808 position "TO" 2" Series 00-CP position L with stainless steel body " Series STO-ACP position R Electrically actuated valves shut

More information

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles -.-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure for STICKTITE and PILOTPK nozzles when fed with an

More information

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung Dr.-Ing. Marco Derksen Contents NOx formation In-furnace NOx reducing measures Application of premixed combustion Experiences in

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2153 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

2.0 Burner Operating Parameters and Requirements

2.0 Burner Operating Parameters and Requirements ECLIPSE INFORMATION GUIDE Silicon Carbide Radiant Auto-Recupes Info 322 2/99 WARNING Handle silicon carbide tubes carefully. Do not drop them or hammer on them. Although they feature excellent mechanical

More information

C C A. Combustion Components Associates, Inc.

C C A. Combustion Components Associates, Inc. C C A Combustion Components Associates, Inc. www.cca-inc.net About CCA CCA is a global provider of combustion control technologies to reduce NOx, particulate matter (PM), unburned carbon and CO emissions

More information

LP BURNER SERIES.

LP BURNER SERIES. LP BURNER SERIES The Limpsfield LP burner series is characterised by a monoblock structure meaning all necessary components can be combined into a single unit, making installation and set-up easier and

More information

North American Automatic Manual Reset and Motorized Valves

North American Automatic Manual Reset and Motorized Valves Combustion North American Automatic Manual Reset and Motorized Valves 1516 Manual Reset 1517 Motorized 1516/1517 Automatic Oil Shutoff Valves Agency approvals: UL, FM, CSA Proof-of-Closure Switch High

More information

HELICAL COIL HEATERS REPLACEMENT PARTS HEATEC AN ASTEC COMPANY HC AND HCS SERIES

HELICAL COIL HEATERS REPLACEMENT PARTS HEATEC AN ASTEC COMPANY HC AND HCS SERIES Publication 9-02-089 rev 1-0 HELICAL COIL HEATERS HC AN HCS SERIES REPLACEMENT PARTS FOR PARTS ON HEATEC PROUCTS uring normal business hours: Phone 800-235-5200 Phone 23-821-5200 After normal business

More information

Eclipse Single-Ended Radiant Tube Burners

Eclipse Single-Ended Radiant Tube Burners 325 Design Guide 3/8/2011 Eclipse Single-Ended Radiant Tube Burners Models SER450, SER600, & SER800 Version 5 Metallic Ceramic Copyright Copyright 2007 by Eclipse, Inc. All rights reserved worldwide. This

More information

Oil, Gas and Dual Fuel Burners

Oil, Gas and Dual Fuel Burners Oil, Gas and Dual Fuel Burners Burner series 130...150 50, 0 Group 3 Capacity 390-3,500 Table of contents General 1 How to choose a burner Light oil burners Technical data and dimensions 3- PI-diagrams

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

FG7T (E and N Series)

FG7T (E and N Series) TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

XIII. Repair Parts 106

XIII. Repair Parts 106 XIII. Repair Parts All Alpine Repair Parts may be obtained through your local authorized U.S. Boiler Company representatives or outlets. Should you require assistance in locating a U.S. Boiler Company

More information

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER CAPABILITIES Industry leading low NOx emissions High momentum. luminous flames at all furnace temperatures High release rates with moderate main combustion air pressure Good turndown with flame characteristics

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

ZEECO BURNER DIVISION

ZEECO BURNER DIVISION ZEECO BURNER DIVISION Enhanced Jet Flat Flame Burners GLSF Series 22151 EAST 91ST STREET BROKEN ARROW OK 74014 USA +1-918-258-8551 SALES@ZEECO.COM ZEECO.COM INTRODUCTION: This document discusses the advantages

More information

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA 1 Description, Types of regulation, Model overview Weishaupt Monarch oil burners are of the fully automatic pressure atomizing type. Their design has

More information

FG7S (C and L Series)

FG7S (C and L Series) TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000

More information

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA TDD-D-1 Vertical boy, boy Front Flue, boy Rear Flue, Downflow/Horizontal Oil-Fired Furnace XP80 / XV80 boy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA Downflow/Horizontal Front Flue TDF1M087A936,V3,SA

More information

Capacities and Operating Data

Capacities and Operating Data CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000

More information

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK Gas burner Dual fuel burner Gas burner Series RG GG MG Dual fuel burner Series MK Series RG Fully automatic gas burner, tested and approved in accordance with DIN EN 676 suitable for the combustion of

More information

Metrovick F2/4 Beryl. Turbo-Union RB199

Metrovick F2/4 Beryl. Turbo-Union RB199 Turbo-Union RB199 Metrovick F2/4 Beryl Development of the F2, the first British axial flow turbo-jet, began in f 940. After initial flight trials in the tail of an Avro Lancaster, two F2s were installed

More information

Model 4WI HP 4 Pass Wet-Back with Integral Burner

Model 4WI HP 4 Pass Wet-Back with Integral Burner Model 4WI 100-800 HP 4 Pass Wet-Back with Integral Burner CONTENTS GENERAL.........................................................................4 FEATURES AND BENEFITS............................................................4

More information