PREMIX TUNNEL BURNERS

Size: px
Start display at page:

Download "PREMIX TUNNEL BURNERS"

Transcription

1 FOR ENCLOSED GASAIR COMBUSTION MODEL: 01, 0, 06 Revision: 0 BULLETIN 01, 0, 06 EXPLODED VIEW Pyronic Tunnel Burners will burn any standard fuel gas at mixture pressures ranging from 0.1 to 60 W. C. Exclusive, patented design of refractory plug E and combustion tunnel insures smooth stable operation. The long annular orifice F reduces back firing even at very low mixture pressures. Turbulence created by the nose plug and the stepped burner block G provides positive flame retention at high mixture pressures with shorter flame length and higher heat release (on std. block only). Pyronic Tunnel Burners are easily lighted at stated mixture pressure. The pilot tip H is screwed into the body to insure permanent and correct location of the pilot flame. A second threaded hole is provided for accurate location of flame electrodes at the junction of the pilot and main flame. DESCRIPTION Integral flanged units are available for pressurized furnaces (see pg. 6). Flange connection of insert D and support spider B with flange C provides: 1. Capacity changes with out removing burner from furnace.. Simplified piping... no unions required.. Mixture pressure test tapping at each burner. 4. Combustion tunnel inspection without removing burner from furnace. 1 Amber St #, Markham Ontario Canada LR 4Z Tel: (0) 47 Fax: (0) 47

2 SELECTION DATA BULLETIN 01, 0, 06 PAGE NO. SELECTION 1. Determine the number of Pyronic Burners required for proper heat distribution.. Divide the total heat required by the number of burners for BTU/hr input to each burner.. Locate Mixture Pressure at burners on Table I under available Air Pressure column. 4. Select Pyronic Burner size required from Table II using BTU/hr per burner and mixture pressure from steps and.. Add letter designating wall mounting assembly to burner catalog number. Example: 101 A (see pg. 4) Burner Model No. Mounting Arrangement Insert (see F008) TABLE I BURNER MIXTURE PRESSURE (INCHES W. C. ) USING FLOMIXERS Air Pressure at Flomixer 4 oz. 8 oz. 1 oz. 16 oz. 0 oz. 4 oz. oz. Mixture Pressure at Burners TABLE II PYRONIC BURNER CAPACITIES Actual * 1000 BTU/hr at Various Mixture Pressures at Burner Inches W. C. (see Table I) Model No. Burner Area Sq. Inches *Coefficient of discharge 0.0 Average

3 BULLETIN 01, 0, 06 PAGE NO. PREMIX TUNNEL BURNERS FLOWMIXER SELECTION DATA A group of Pyronic Tunnel burners may be manifolded to a single Flomixer. Table III below shows the correct Flomixer for various combinations of the same size burners. On applications that require long mixture piping, use several Flomixers to reduce pressure losses. Mixture piping must be at least as large as the Flomixer outlet size. HIGH PRESSURE GASES For selection of proper Hijector for combinations of Pyronic Burners, refer to Hijector Bulletin 01. Use total port area for mixer selection. No. HPST Pilot (Bulletin 70) can be used for all gases when single burner is required. Model No TABLE III FLOWMIXER SELECTION ALL GASES Model Number of Flomixer (No. 4 Ass'y.) To Supply Number of Burners Shown Select number of burners required using capacity table II and mixture pressure table I. 1 Amber St #, Markham Ontario Canada LR 4Z Tel: (0) 47 Fax: (0) 47

4 PILOT ASSEMBLIES MOUNTING ARRANGEMENTS BULLETIN 01, 0, 06 PAGE NO. 4 BLAST PILOT SELECTION Model No. Description Pilot Tips and Mixers 16BTSA Spark alloy blast tip only 1/ pipe connection with 8 Flexible Tubing. Pipe Connections Mixer for number of Tips below Air Gas Mix 1MMCR 1MMCR 14MMCR 16MMCR 1 only 4 6 1/4 1/ /4 Reversible mounting flanges permit application to a wide variety of wall thickness. 1/4 1/ /4 MOUNTING ARRANGEMENTS Midget Mixer Assembly including Air Cock, Combination gas cock ratio adjuster, gas regulator and midget mixer sized to handle number of pilot tips shown. A assemblies are held in place by cementing into the wall. All other assemblies are normally attached to the wall by bolts or studs in the slotted openings provided on the flange periphery. SELECTION OF MOUNTING ASSEMBLY TO FIT WALL THICKNESS Pyronic Letter Indicates Type of Wall Mounting Above Wall Thickness Inches Burner B B C C D D E* E E B B C C D D E* E E 16 B B B C C D D E E E 0 B B C C C K* K K K 4 B B C C C K* K K K Blocks Flush or Slightly Recessed. *Blocks Extend Beyond Furnace Wall up to 1/. Flame Detectors adaptable to A, B, & C mountings only.

5 DIMENSIONS BULLETIN 01, 0, 06 PAGE NO. A ASSEMBLY DIMENSIONS (IN INCHES) P Q S X Y Z No. 101 B 101 C B C 16 B 16 C 0 B 0 C 0 K 4 B 4 C 4 K Inlet Pipe Size No. 101 A A 16 A 0 A 4 A Inlet Pipe Size /4 / 1/ Pilot & Flame Electrode Conn. () 1/ 1/ 1/16 17/ 17/ Min. Wall Thickness 1/4 1/4 7/4 81/8 81/8 Overall Length ± 1/8 14 Block Square P Q R S T U W X Y Z Overall Min. Wall Bolt Size Length ± Thickness 1/8 /4 /4 / / 1/ 1/ 1/ For Shell Cutout Add 1/4 to Z B, C, K ASSEMBLY DIMENSIONS (IN INCHES) 4/8 4/8 1/4 1/4 For Shell Cutout Add 1/4 to W Only One U Notch Centered On Side. Pilot And Flame Electrode Connection (). 71/ 71/ 71/ 71/ /4 / /4 /4 6/4 /4 6/4 6/4 8/4 71/8 1/8 71/8 1/ Block Square 7 7 Lbs. / / Lbs. / / / / D, E ASSEMBLY DIMENSIONS (IN INCHES) No. 101 D 101 E D E 16 D 16 E P Q R S T U W X Y Z Pilot & Wall Overall Flame See Note Min. Wall Bolt Size Bracket Length ± Electrode Thickness Square 1/8 Conn. () Inlet Pipe Size / / / / / Pipe For Shell Cutout Add 1/4 to W or Z 71/ 101/ 71/ 101/ 10/8 1/8 1 1 Block Square Amber St #, Markham Ontario Canada LR 4Z Tel: (0) 47 Fax: (0) 47

6 GAR & GA DIMENSIONS BULLETIN 01, 0, 06 PAGE NO. 6 Style GAR & GA Burners having the same capacities and Flange surface is machined for gasket tight seal of construction are available with an integral mounting flange pressures up to 10 PSIG. Applications include especially designed for pressurized combustion chambers. pressurized air heaters, atmosphere generators and other sealed furnaces or retorts. GAR (0) Model No. A B C D E Lbs. Kgs. 101 GAR 4 41/4 8/4 1/ / GAR 4 41/4 8/4 1/ / GAR 1/ 6/4 1/ GAR 7 81/4 1/4 8 1/ GAR 7 81/4 1/ GA (06) Model No. A B C D E F G H Lbs. Kgs. 16 GA 1/ /8 6/ GA 6 1 1/ 8 7 1/ GA /8 87.4

7 ASSEMBLIES FOR PREMIX TUNNEL BURNERS F008 ASSEMBLIES MODEL NO. 101 & TUNNEL BURNERS MODEL NO. PART NUMBER DIA. 4770C C C C C C C C C C C * 1784C * 1784C 0.6 1* 1784C * 1784C MODEL NO. ASSEMBLIES MODEL NO. 16 TUNNEL BURNERS PART NUMBER DIA C C C C C C C * 17C * 17C * 17C * 17C * 17C * 17C * 17C * 17C * 17C0 1.4 * 17C10 ASSEMBLIES MODEL NO. 0 & 4 TUNNEL BURNERS MODEL NO. PART NUMBER DIA C C C C C C C C C C C.47 1* 1718C * 1718C0.7 1* 1718C0.4 * 1718C04.1 * 1718C0.81 4* 1718C06.0 * 1718C * 1718C NOTE: 1. Insert sizes listed are the maximum to minimum diameters allowed per tunnel burner size.. Insert model numbers marked with asterisks (*) indicate SPECIAL ASSEMBLIES and are to be priced accordingly.. Insert diameters are in inches. 1 Amber St #, Markham Ontario Canada LR 4Z Tel: (0) 47 Fax: (0) 47

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB TORCH BURNERS LOW, MEDIUM, AND HIPRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB Revision: 0 BULLETIN 325, 32, 327 2 ET 2 RETB DESCRIPTION Torches are made up in three series LowPressure,

More information

1200 SERIES FTR HOT AIR BAFFLE BURNER

1200 SERIES FTR HOT AIR BAFFLE BURNER CAPABILITIES High release rates with moderate air pressure Good turn down with flame characteristics and direction maintained Stable flames tailored to the job applications can be from highly oxidizing

More information

1466 SERIES COLD AIR GAS/OIL BURNER

1466 SERIES COLD AIR GAS/OIL BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light wall construction FEATURES

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire

More information

Design and Application Details

Design and Application Details LO-NOX Line Burners Page 5803 Design and Application Details Total heat release and LO-NOX Burner footage are normally selected from the tables given in the Series HG Mixing Tube section of the Maxon catalog

More information

1070 SERIES ULTRA LOW NO X

1070 SERIES ULTRA LOW NO X CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing

More information

MULTIFIRE. High temperature dual fuel burner

MULTIFIRE. High temperature dual fuel burner MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,

More information

2.0 Burner Operating Parameters and Requirements

2.0 Burner Operating Parameters and Requirements ECLIPSE INFORMATION GUIDE Silicon Carbide Radiant Auto-Recupes Info 322 2/99 WARNING Handle silicon carbide tubes carefully. Do not drop them or hammer on them. Although they feature excellent mechanical

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK -II Gas Page 2153 Design and Application Details OVENPAK -II s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are

More information

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2153 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures

More information

1470 SERIES HOT AIR GAS BURNER

1470 SERIES HOT AIR GAS BURNER 1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light

More information

North American 4575 HiRAM

North American 4575 HiRAM Combustion North American 4575 HiRAM The quality and performance of our Tempest, but bigger. Low NOx burner High Velocity - High Turndown Inputs to 4-25 million Btu/hr Direct Spark or Pilot Lighting Furnace

More information

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles Low Temperature Burners - STICKTITE and PILOTPK Nozzles STICKTITE & PILOTPK Flame retention nozzles -.- For open-port firing or open environment firing Provides positive flame retention and stable clean

More information

Eclipse Vortometric Burners Series HI

Eclipse Vortometric Burners Series HI Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas)

More information

Introduction. System Components

Introduction. System Components The Selectra SERIES 94 is for use with either direct or indirect gas fired units (furnaces, ovens, etc.). The system may be field installed on existing equipment or specified for new equipment installation.

More information

KINEMAX. Medium velocity gas or oil burners

KINEMAX. Medium velocity gas or oil burners KINEMAX Medium velocity gas or oil burners High Temperature Burners - KINEMAX -.- Exit velocities up to 00 km/h (8 m/s) to promote workload heat penetration and better furnace temperature uniformity Operate

More information

North American Combustion Burners

North American Combustion Burners Combustion North American Combustion Burners 4441 North American Tempest High Velocity Gas Burner Jet action burner offering superior recirculation Slotted tile produces exceptional temperature uniformity

More information

North American Combustion Burners

North American Combustion Burners Combustion North American Combustion Burners 4441 North American Tempest High Velocity Gas Burner Jet action burner offering superior recirculation Slotted tile produces exceptional temperature uniformity

More information

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles -.-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure for STICKTITE and PILOTPK nozzles when fed with an

More information

Burners. Pilot Heads BTC & BTSA (E3121 rev /04/2018)

Burners. Pilot Heads BTC & BTSA (E3121 rev /04/2018) Burners Pilot Heads BTC & BTSA (E3121 rev. 02-24/04/2018) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the norms present

More information

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles Low Temperature urners - STICKTITE and PILOTPK Nozzles 1-1.1-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure

More information

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility -.9- KINEDIZER LE High capacity low NOx gas burners Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility Lower NOx and less excess air than standard KINEDIZER

More information

IMMERSION FIRED HOT WATER BOILER

IMMERSION FIRED HOT WATER BOILER 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series

More information

Pilot Capacities/Specifications

Pilot Capacities/Specifications s Page 9505 Capacities/Specifications Maxon offers a wide range of gas pilots to meet the specific needs of each of its burner product lines. In most cases, the appropriate burner catalog section will

More information

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING HIGH EFFICIENCY BURNER ASSEMBLY HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING This manual must be read in its entirety before installation of this burner. Installation must be performed by a

More information

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes Info 110 4/98 RatioMatic Burners RM Series version 1.01 50 through 600 Sizes 750 through 2000 Sizes For Ratiomatic Serial Numbers 95-5500 and Above Version 1.01 7/97 Contents 1.0 Operating Parameters &

More information

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign 3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot

More information

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750 Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact

More information

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION SF-200 OCTOBER 10, 2016 SureFire II TM Pilot Forced Draught Gas Pilot type SP-32-xx-FD Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-32-xx-FD gas pilot

More information

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

X4 Installation and Operation Manual - POWER FLAME INCORPORATED 7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice

More information

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000 Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged

More information

North American 4485 Tempest SE

North American 4485 Tempest SE Combustion North American 4485 Tempest SE Medium/High Velocity Gas Burner Low NOx gas burner, durable construction and flexible desgin to fit a variety of applications. NPT or BSP air/gas inlets, adjustable

More information

Economite RE Series. Power Gas Burners. MADE in the USA

Economite RE Series. Power Gas Burners. MADE in the USA Economite RE Series MADE in the USA Economite RE 4000 Series MADE in the USA Midco s Economite Family of Burners Backed by 60 Years of Experience 4.00" 6.00" 12.00" RE 4400DS 9.00" 15.75" 20.50" 8.44"

More information

Start-up Instructions

Start-up Instructions RadMax Burners Page 400-S- Start-up Instructions Read complete instructions before proceeding and familiarize yourself with all the system s equipment and components. Verify that all equipment has been

More information

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual SF-200 APRIL 10, 2018 Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-32-NG/PG-FD gas

More information

Specifications of OPTIMA SLS Burners

Specifications of OPTIMA SLS Burners 1.1.9-4 Low emperature urners - PIM L pecifications of PIM L urners ypical burner data Fuel: natural gas at 60 F with 1000 tu/ft 3 (st) HH - sg = 0.6 (1) ombustion air: 60 F - 21% 2-50% humidity - sg =

More information

7. SERVICING AND COMPONENT ADJUSTMENTS

7. SERVICING AND COMPONENT ADJUSTMENTS 7. SERVICING AND COMPONENT ADJUSTMENTS General Information on Internal Bypass Oil Systems 1. The system is designed to use 300 PSI pressure at the nozzle inlet at low and high fire (and throughout the

More information

Specifications of MAXON VALUPAK burners for 50 Hz operation

Specifications of MAXON VALUPAK burners for 50 Hz operation 1-1.5-7 Specifications of MAXON VALUPAK burners for 50 Hz operation Capacity data in kw Gross heating value = 10.9 kwh/m 3 (st), d = 0.6. All figures are for balanced - 0 mbar - duct pressure VALUPAK size

More information

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH Info 140 11/4/03 ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X

1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X 1500 SERIES LRGE CPCITY ULTR 2 LOW NO X URNER CPILITIES High release rates with moderate air pressure Good turndown with flame characteristics and direction maintained Stable flames can range from highly

More information

SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual

SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual SF-500 September 10, 2018 SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-48-NG/PG-ND gas pilot

More information

TECHNICAL SERVICE BULLETIN

TECHNICAL SERVICE BULLETIN INTERNATIONAL, INC. 159 PARIS AVENUE NORTHVALE, NJ 07647 PHONE 201-768-2400 TECHNICAL SERVICE BULLETIN Date: 08/19/05 Number: 2005-03 Subject: KC1000 LOW NOx CONVERSION KIT INSTRUCTIONS Page 1 of 42 1.

More information

Metrovick F2/4 Beryl. Turbo-Union RB199

Metrovick F2/4 Beryl. Turbo-Union RB199 Turbo-Union RB199 Metrovick F2/4 Beryl Development of the F2, the first British axial flow turbo-jet, began in f 940. After initial flight trials in the tail of an Avro Lancaster, two F2s were installed

More information

Burners. Pilot Heads BTC & BTSA (E3121 rev /09/2010)

Burners. Pilot Heads BTC & BTSA (E3121 rev /09/2010) Burners Pilot Heads BTC & BTSA (E3121 rev. 01-06/09/2010) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the norms present

More information

Assembly Numbers Style A, B & C LINOFLAME Burners

Assembly Numbers Style A, B & C LINOFLAME Burners Premix-type Line Burners Page 00-A/P-1 Style A, B & C LINOFLAME Burners S tyle A, B & C LINOFLAME Burners with cast iron ignition rails L INOFLAME Burner Section Description straight section (Code) S tyle

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-06EN - Edition 06-01/12/2010 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

Top M37 Truck, Cargo. Assy Tree for: M37 Printed 12/27/ /4t 4x4 M37. Item Qty P/N Title Detail Ref(m) 1 1 M37 GROUP 01

Top M37 Truck, Cargo. Assy Tree for: M37 Printed 12/27/ /4t 4x4 M37. Item Qty P/N Title Detail Ref(m) 1 1 M37 GROUP 01 Assy Tree for: Type Revision Status Date By CAT U 11/5/2006 G741.ORG NSN Serial # Bumper # Reference # User5 Top 1 1 GROUP 01 Engine 1 1 0100 Engine assembly Engine installation hardware 1 1 2805-621-5566

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-04EN - Edition 04-01/04/2008 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER CAPABILITIES Industry leading low NOx emissions High momentum. luminous flames at all furnace temperatures High release rates with moderate main combustion air pressure Good turndown with flame characteristics

More information

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER CAPABILITIES Short, compact, clear and bushy flame Suitable for rich gases and most oils 10% to 300% excess air through burner with rich gaseous fuels and light oils 10% to 100% excess air through burner

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS COMBI GAS OVENS MODELS ML-126836 ML-126837 ML-126838 VCG10H VCG10F VCG20H For additional information on Vulcan-Hart Company or to locate an authorized parts and service provider

More information

Table of Contents. 1900/P3 Series Exposed spring design - The spring in this design is exposed for atmospheric cooling. D through T orifice sizes.

Table of Contents. 1900/P3 Series Exposed spring design - The spring in this design is exposed for atmospheric cooling. D through T orifice sizes. Scope of Design Table of Contents Scope of Design...............................................................1900P.1 Materials 1900/P1 (Conventional)......................................................1900P.3

More information

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction BBG Gas Beta Burner BBG-1 Edition 02-08 BBG shown with pilot ignition and converging tile options. Designed for low pressure air operation Rugged heavy gauge steel construction Alloy or refractory tile

More information

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS MDEL C/C S IR R STEM LIHT IL TMIZIN FRCED DRFT BURNERS Power Flame s Versatile High Performance ir or Steam tomizing Light il Burner djustable Premix Firing Head Produces optimum fuel/air mixture within

More information

Doing more for clean environment and energy saving

Doing more for clean environment and energy saving Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one

More information

Low emissions, high performance natural gas burners

Low emissions, high performance natural gas burners -.6- OVENPAK LE Burners Low emissions, high performance natural gas burners Burns any clean fuel gas Operates on low gas supply pressures Provides clean combustion with low NOx and CO levels Compact burner

More information

Size: 57 (140 cm) W. x 30 (75 cm) D. x 75 (190 cm) H.

Size: 57 (140 cm) W. x 30 (75 cm) D. x 75 (190 cm) H. Model TF-1100 6 DIA. X 18 Work Area Inconel Retort Furnace For programmed continuous operation to 1100 o C in dry or wet Hydrogen. Size: 57 (140 cm) W. x 30 (75 cm) D. x 75 (190 cm) H. Standard Features

More information

REPLACEMENT PARTS LIST. M1 Series

REPLACEMENT PARTS LIST. M1 Series REPLACEMENT PARTS LIST M Series Model MG(*) Item Description MGH MG(B,C,D) 056 070 077 090 056 070 077 090 Louvered Door (White) 9007 9007 9007 9007 9007 9007 9007 9007 Coil Door (White) 9009 9009 9009

More information

Performance Selection Data

Performance Selection Data Series "NP" & "RG" AIRFLO Burners Page 5505 Performance Selection Data Operation in shaded area requires special considerations Optimum Design Area Operation in shaded area requires special considerations

More information

GEMINI GAS CONTROL PRODUCT INFORMATION

GEMINI GAS CONTROL PRODUCT INFORMATION GEMINI GAS CONTROL PRODUCT INFORMATION The Gemini (6G) combination gas control valve is a versatile multifunction control designed to meet the requirements for use with non-piloted intermittent ignition

More information

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF

More information

Table of Contents Click to go to section

Table of Contents Click to go to section Table of Contents Click to go to section Section I Product Bulletin Section II Safety Statement Safety and Hazard Recognition Hazard Recognition Basic Safety Guidelines Hazardous Work Permit Flammable

More information

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12) VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT RULE 74.15.1 - BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12) A. Applicability The provisions of this

More information

Crest Heating Boilers FBN(L)

Crest Heating Boilers FBN(L) Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 59 IMG01113 52 65

More information

J Series Pilot Burners/Y90 Series Inlet Fittings

J Series Pilot Burners/Y90 Series Inlet Fittings Product Bulletin Issue Date September 8, 2008 J Series Pilot Burners/Y90 Series Inlet Fittings J Series Pilot Burners/Y90 Series Inlet Fittings are used with Intermittent Pilot Ignition (IPI) and Standing

More information

Q345A, Q3451, Q3481, Q348A, Q348B, Q362A, Q373A, Q381A and Q3452 Intermittent Pilot Burner/Igniter-Sensors PRODUCT DATA

Q345A, Q3451, Q3481, Q348A, Q348B, Q362A, Q373A, Q381A and Q3452 Intermittent Pilot Burner/Igniter-Sensors PRODUCT DATA QA, Q, Q8, Q8A, Q8B, Q6A, QA, Q8A and Q Intermittent Pilot Burner/Igniter-Sensors PRODUCT DATA FEATURES QA, Q8A, Q8B and QA Intermittent Pilot Burner/Igniter-Sensors are compatible with all Honeywell intermittent

More information

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM).

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM). Page 1 of 8 Published : Apr 22, 2004 Auxiliary Heater COMPONENT LOCATIONS Item Part Number Description 1 - Fuel line connection with fuel tank 2 - Auxiliary fuel pump 3 - Fuel fired booster heater GENERAL

More information

Installation Instructions for. For Use When Converting Model (V)M42(B) Vented Decorative Fireplace. Fold Bi-Fold Door After Releasing

Installation Instructions for. For Use When Converting Model (V)M42(B) Vented Decorative Fireplace. Fold Bi-Fold Door After Releasing Installation Instructions for PCBM-42 conversion kit Converting from Natural Gas to Propane/LP Gas For Use When Converting Model (V)M42(B) Vented Decorative Fireplace This conversion kit must be installed

More information

Turbo Pressure Blowers

Turbo Pressure Blowers www.americanfan.com Bulletin VP4 Turbo Pressure Blowers Howden Industrial Fan Group American Fan / Joy Fan / Garden City Fan Features Heavy gauge continuously welded housings, reversible and rotatable

More information

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators 627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated reducing regulators (Figure 1) are for low and high systems. These regulators can be used with natural gas, air, or a

More information

SPARE PARTS LIST - July

SPARE PARTS LIST - July Versions for CANADA SPARE PARTS LIST - July 2005 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is

More information

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Models MD-25-OG MD-7500-OG December 2012 Copyright 2012 Periflame, Design Guide 113 Industrial Dual-Fuel Burners, 12/01/2012

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL OIL FIRED FURNACE Models: FH05V4A FH110V4A General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of pages shown

More information

Lecture 27: Principles of Burner Design

Lecture 27: Principles of Burner Design Lecture 27: Principles of Burner Design Contents: How does combustion occur? What is a burner? Mixing of air and gaseous fuel Characteristic features of jet Behavior of free (unconfined) and confined jet

More information

Data 330-3 9/15/07 Eclipse ImmersoJet Burners Model 3 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr)

More information

SECTION 4 - FUEL SYSTEMS AND CARBURETION

SECTION 4 - FUEL SYSTEMS AND CARBURETION SECTION - FUEL SYSTEMS AND CARBURETION FUEL SYSTEMS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -62 FUEL PUMP - - - - - - -

More information

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP Space Heaters This Parts Listing has been compiled for your benefit. You can be assured your space heater was constructed and designed with quality and performance

More information

PGM Prepiped Gas Manifold

PGM Prepiped Gas Manifold PGM Prepiped Gas Manifold PGM-1 Edition 03-09 Prepiped and assembled for easy installation Suitable for single and multiple burner applications Automatic safety shutoff valves with visual indication and

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. Parts List 0-July-20 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. 9% Gas Furnaces Table of Contents Model Explanation...................................................................................................................

More information

Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A.

Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A. Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A. 2001 South 21st Street Phone 620-421-0480 Parsons, KS 67357 FAX 620-421-0948 Web Site: http://www.powerflame.com E-Mail: CSD@powerflame.com

More information

Replacement parts. Table 6. Item Description Part no. A Regular front section

Replacement parts. Table 6. Item Description Part no. A Regular front section Replacement parts Table 6 Series 3 section and flue collector parts Item Description Part no. A Regular front section 7022 316-700-215 B B C D E Wide intermediate section (WGO-3) 7010 Narrow intermediate

More information

VALUPAK. Packaged gas burners

VALUPAK. Packaged gas burners VALUPAK Packaged gas burners 1-1.5-1 E - i - 11/14 High turndown. Available in 6 sizes. Capacities: 0.007 MBtu/hr - 4 MBtu/hr. Stable and clean combustion. Suitable for UV scanner and flame rod. Natural

More information

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance Features & Benefits Table of Contents Features & Benefits................................................................ 13900.1 Scope of Design...................................................................

More information

OIL FIRED FURNACE REPLACEMENT PARTS MANUAL FLF085D36C FLF110D48C. Models: Contents. General Notes. Important

OIL FIRED FURNACE REPLACEMENT PARTS MANUAL FLF085D36C FLF110D48C. Models: Contents. General Notes. Important REPLACEMENT PARTS MANUAL OIL FIRED FURNACE Models: General Notes Contents Revised and/or additional pages may be issued from time to time. A complete and current manual consists of pages shown in the following

More information

SPARE PARTS CATALOGUE. - July

SPARE PARTS CATALOGUE. - July SPARE PARTS CATALOGUE - July 2008 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is the meaning of

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Product Bulletin Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve The G196 Series valves use the reliable valve body and magnetic operators from

More information

Spare parts list I RSF 22/04/

Spare parts list I RSF 22/04/ Spare parts list 6720620019 28I RSF 22/04/2009 6720620019 1 22/04/2009 6720620019 2 22/04/2009 6720620019 3 Spare parts list 1 Pump / Hydraulic assy 22/04/2009 6720620019 4 Pos description S-Nr ordering

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 Technical Data SD 3001E PRINTED IN U.S.A. SD 3001E/9709 SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 A B TYPE E MAIN VALVE FACE TO FACE DIMENSIONS C D E DIMENSIONS (inches)

More information

ENGINEERED PRODUCTS. Project: Unit Tag: MS-80-D-3 Page 1 of 5

ENGINEERED PRODUCTS. Project: Unit Tag: MS-80-D-3 Page 1 of 5 ENGINEERED PRODUCTS Model - Unit Type (UT) - MS, Separated Combustion Indoor Unit Capacity (CA) - (50-80) (500-800 mbtu) Furnace Type (FT) - A, B Standard Temperature Rise (30-80)F Indoor Arrangement (IA)

More information

A.O. SMITH WATER PRODUCTS CO., INC W. 115TH STREET ALSIP, ILLINOIS Phone: Fax: Website:

A.O. SMITH WATER PRODUCTS CO., INC W. 115TH STREET ALSIP, ILLINOIS Phone: Fax: Website: PSD-3-152/a WIRING/HARNESS & PROBES See page 8 PROPANE GAS TRAIN ASSEMBLY See page 6 COMMERCIAL POWER BURNER BOILER REPLACEMENT PARTS LIST COPPER BOILERS FOR HYDRONIC HEATING & HOT WATER SUPPLY LEGEND

More information

CONVENTIONAL ENGINE CONSTRUCTION

CONVENTIONAL ENGINE CONSTRUCTION CONVENTIONAL ENGINE CONSTRUCTION CYLINDER BLOCKS, HEADS, AND CRANKCASES The cylinder, or the engine block, is the basic foundation of virtually all liquid-cooled engines. The block is a solid casting made

More information

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners W 8ST R COMBUSTION A Selas Heat Technology Company Model HDR - RF Manual Addendum (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners With and without Low NOx Flue Gas Recirculation

More information

Service and installation must be performed by a trained/experienced service technician.

Service and installation must be performed by a trained/experienced service technician. CATALOG Service and installation must be performed by a trained/experienced service technician. All products used with combustible gas must be installed and used strictly in accordance with the instructions

More information

Legacy Combustion Chamber Replacement Kit

Legacy Combustion Chamber Replacement Kit H0324700- Replacement Kit Instructions WARNING FOR YOUR SAFETY - This product must be installed and serviced by authorized personnel, qualifi ed in pool/spa heater installation. Improper installation and/or

More information

Liquid Strainers. Protect nozzles, valves and pumps from damaging debris. Experts in Spray Technology Spray Nozzles. Spray Fabrication.

Liquid Strainers. Protect nozzles, valves and pumps from damaging debris. Experts in Spray Technology Spray Nozzles. Spray Fabrication. Experts in Technology Nozzles Control Analysis Fabrication Liquid Strainers Protect nozzles, valves and pumps from damaging debris. Table of Contents T Strainers Low to Medium Pressure TW...3 TWC...3 TWF...4

More information