Economite RE Series. Power Gas Burners. MADE in the USA

Size: px
Start display at page:

Download "Economite RE Series. Power Gas Burners. MADE in the USA"

Transcription

1 Economite RE Series MADE in the USA

2 Economite RE 4000 Series MADE in the USA Midco s Economite Family of Burners Backed by 60 Years of Experience 4.00" 6.00" 12.00" RE 4400DS 9.00" 15.75" 20.50" 8.44" 15.19" 6.75" 132,000 to 400,000 Btu/Hr RE 4400DS Direct Spark Ignition 7" 8 7" 8 3 5" 8 2 RAD. 4 3" 4" RAD. 3 3" RAD " " RAD " 4 7" SLOT 16 WIDTH 4 Flange for RE 4000 Series Models - RE 4400DS RE 4700BA RE 4850A RE 4850BA 4" DIA. 4.00" 6.75" RE 4700BA 15.75" 9.00" 21.25" When You Need to Turn On the Heat Choose Midco 230,000 to 700,000 Btu/Hr RE 4700BA

3 Assembled, Factory Fired Tested And Ready for Installation 12.00" 4.00" 6.5" RE 4850BA 23.56" 30.31" 6.75" 9.00" 15.75" 21.00" Flexible, Compact Design 280,000 to 850,000 Btu/Hr RE 4850BA 4.12" 9.5" 9.00" 15.85" RE 4850A 12.00" 9.00" 24.12" 16.00" 280,000 to 850,000 Btu/Hr RE 4850A 120 Volt Control and Gas Train 23.16" 38.90" 15.70" Whether you purchase a standard unit or have us create one to fi t your application, you can be assured of having purchased the fi nest power gas burner in the industry. Quality Designed for Proven Performance

4 16.25" 16.25" BI S BURNER CONTROL Economite RE 6000 Series 6.50" 8.50" 6.75 " 14.25" RE 6700B BI " 15.33" 25.64" 10.30" 6 Flange for RE 6000 Series Models RE 6700B RE 6850 RE 6850B ,000 to 700,000 Btu/Hr 60 RE 6700B 10.0" 6.5" 6" 1.25" 4.2".5".8" 6.50" 8.50" 7.50" 14.25" RE " BI 3152 Honeywell 22.50" " 36.50" 10.25" 6.50" 8.50" 7.50" 14.25" RE 6850B " 22.50" 26.25" 36.50" 10.25" Dependable Performance RE ,000 to 825,000 Btu/Hr RE 6850B - 275,000 to 825,000 Btu/Hr RE 6850 & RE 6850B Control and Gas Train: RE Volt RE6850B - 24Volt

5 Economite RE Series The Economite RE Series retention head shapes the flame into a compact flame pattern. This design concentrates heat to the most efficient heat exchange surfaces Features & Benefits The RE Series Technology Provides a uniform heat throughout the length of the heat exchanger creating consistent heat distribution characteristics... increased combustion effi ciency by reducing the volume of oxygen used for the combustion process RE4400DS... operation under variable draft or positive pressure conditions The RE Series Has sheet metal construction allowing high volume production resulting in competitive pricing and shorter lead-times... a simple removable burner cartridge for easy service... an optional welded fl ange assembly is available to accommodate OEM specifi cations... an external air shutter for easy adjustment... full burner capacity fi ring up to 1/2 W.C. positive combustion chamber pressure... a universal adjustable mounting fl ange making installation fast and easy The RE Series Is pre-piped, pre-wired and factory fi re tested... available with UL / FM / GAP valve trains and controls... customizable in confi gurations to meet your needs Specifications MADE in the USA Applications The RE Series is engineered to serve a wide variety of applications or can be customized to accommodate the OEM s specifi c requirements. Agricultural Processing Baking Ovens Boilers Coffee Roasting Equipment Furnaces Food Service Equipment Pressure Washers Incinerators Micro Brewing Crop Drying Process Ovens Space Heating Spray Booths Water Heaters Contact Midco for gas burner application assistance RE Series 132,000 Btu/hr to 850,000 Btu/hr RE4850BA Model Minimum Maximum Gas Gas Pressure 3 Diameter Maximum Motor Design Primary Shipping Number Firing Firing Connection Required Natural of Nozzle HP Certification or Safety Weight Rating * Rating * Pipe Size or Propane Nozzle Insertion Depth Listed by Voltage RE4400DS 132,000* 400,000* ¾ NPT 7.0 to 14.0 W.C /6 1 U.L./C.U.L Listed 24V 40 lb RE4700BA 230,000* 700,000* 1 NPT 7.0 to 14.0 W.C /6 1 U.L./C.U.L Listed 24V 47 lb RE4850BA 280,000* 850,000* 1 NPT 7.0 to 14.0 W.C /6 1 U.L./C.U.L Listed 24V 55 lb RE4850A 280,000* 850,000* 1 NPT 7.0 to 14.0 W.C /6 1 U.L./C.U.L Listed 120V 59 lb RE6700B 275,000* 700,000* 1 NPT 6.0 to 14.0 W.C /7 2 U.L./C.U.L Listed 24V 47 lb RE6850B 275,000* 825,000* 1 NPT 6.0 to 14.0 W.C /7 2 U.L./C.U.L Listed 24V 50 lb RE ,000* 825,000* 1 NPT 6.0 to 14.0 W.C /7 2 U.L./C.U.L Listed 120V 50 lb * Btu/Hr - Electrical Supply 115 / 1 / 60 1 as standard - Available in Natural and LP - LP requires a conversion kit Gas Burner Draft Motors / 1 / / 1 / 60 Gas Burner Draft Motors / 1 / 60 1 & 2 Contact Midco for 50 Hz Applications (non-ul Listed) 3 For Lower Gas Inlet Capacities Contact Midco The RE Series is an assembled power burner with an ignition control system. For further information please contact sales@midcointernational.com

6 MADE in the USA Quality Designed for Proven Performance Midco International Inc West Victoria Street - Chicago, Illinois toll free: tel: fax: web: sales@midcointernational.com Printed in USA

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign 3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948

More information

M SERIES TECHNICAL DATA INFORMATION PACKET

M SERIES TECHNICAL DATA INFORMATION PACKET M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical

More information

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING HIGH EFFICIENCY BURNER ASSEMBLY HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING This manual must be read in its entirety before installation of this burner. Installation must be performed by a

More information

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Product Bulletin Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve The G196 Series valves use the reliable valve body and magnetic operators from

More information

Capacities and Operating Data

Capacities and Operating Data CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000

More information

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This

More information

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This

More information

Burner Selection Criteria

Burner Selection Criteria UNI-RAD Radiant Tube Burners Page 4803 Burner Selection Criteria Combustion Air View Port/Optic Flame Sensor Mount Gas Inlet 3"- 4" Burner Selection The UNI-RAD Burner can be used with various radiant

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners W 8ST R COMBUSTION A Selas Heat Technology Company Model HDR - RF Manual Addendum (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners With and without Low NOx Flue Gas Recirculation

More information

PREMIX TUNNEL BURNERS

PREMIX TUNNEL BURNERS FOR ENCLOSED GASAIR COMBUSTION MODEL: 01, 0, 06 Revision: 0 BULLETIN 01, 0, 06 EXPLODED VIEW Pyronic Tunnel Burners will burn any standard fuel gas at mixture pressures ranging from 0.1 to 60 W. C. Exclusive,

More information

Data 330-3 9/15/07 Eclipse ImmersoJet Burners Model 3 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr)

More information

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design 97311 The S&J 97311 Enclosed burner incinerates harmful emissions from waste gas streams. Typical applications include fermentation off gas piping systems such as anaerobic digesters or landfill gas. This

More information

OIL FURNACES Clean, Comfortable Oil Heat

OIL FURNACES Clean, Comfortable Oil Heat OIL FURNACES Clean, Comfortable Oil Heat Features Foil-faced high density fiberglass insulation to minimize noise and heat loss Heavy duty 14 gauge steel heat exchanger engineered for efficiency; covered

More information

CGa - Series 1 & 2 Section Assembly Parts

CGa - Series 1 & 2 Section Assembly Parts CGa - Series & Section Assembly Parts 0 Part Description Mfr. Mfr. s Part Boiler -0-0 End Section, Left Hand, Cast # -0- End Section, Right Hand, Cast # -0- Intermediate Section, Cast #, -- -- Replacement

More information

DEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc.

DEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc. DEXEN INDUSTRIES Inc. GENERAL CATALOG DEXEN INDUSTRIES Inc. 6003 GAS VALVES 6003-series gas valve is an effective and reliable gas valve for low-btu gas product and application. The product is most commonly

More information

MULTIFIRE. High temperature dual fuel burner

MULTIFIRE. High temperature dual fuel burner MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,

More information

GB162 Series Boiler TR & TL Cascade Kit Configurations

GB162 Series Boiler TR & TL Cascade Kit Configurations TR & TL Cascade Kit Configurations Engineering Submittal Sheet Cascade Overview C US Engineering Specifications There shall be provided a Buderus GB162 TR or TL condensing hot water boiler cascade kit

More information

Setting the Standard

Setting the Standard Setting the Standard Improved control and less maintenance. Electronic asphalt pump speed control provides superior dependability and more precise control than manual systems. The application rate is automatically

More information

1070 SERIES ULTRA LOW NO X

1070 SERIES ULTRA LOW NO X CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel 97311T Designed for complete automatic operation of the entire Burner System, the S&J 97311T Enclosed Flare and Touch Screen Control Panel is specifically designed to operate efficiently with low BTU anaerobic

More information

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF

More information

Pilot Burners. Universal Pilot Burners A /08/12

Pilot Burners. Universal Pilot Burners A /08/12 24/08/12 A124-1 Universal Universal Fit - This pilot burner offers adjustable mounting options, flexible hood orientations and the accessories needed for replacement Universal fittings and compact size

More information

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & 101

More information

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility -.9- KINEDIZER LE High capacity low NOx gas burners Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility Lower NOx and less excess air than standard KINEDIZER

More information

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET PROFIRE V SERIES TEHNIA DATA INFORMATION PAKET Technical Data Uncontrolled Emissions onfiguration (VG, V, VG) 1.3-16.8 MM BTU/H NG; 9.3-120 GPH #2 OI U listed with choice of NFPA, SD-1, GAP, and FM for

More information

S1 SERIES TECHNICAL DATA INFORMATION PACKET

S1 SERIES TECHNICAL DATA INFORMATION PACKET S1 SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions S1G, S1L, S1LG Technical Data Sheet...3 Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions S1E, S1EG Technical

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire

More information

Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: NEOTHERM Hydronic Boiler NTH Hydronic Boiler Indoor Sizes 285-850 Date: Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment High condensing

More information

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH Info 140 11/4/03 ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower

More information

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.

More information

RANGE For 30 models White /4 x 2-1/ F222 Left (shown) 1805F223 Right Includes rivets Used on 24, 30 & 36 ranges

RANGE For 30 models White /4 x 2-1/ F222 Left (shown) 1805F223 Right Includes rivets Used on 24, 30 & 36 ranges ANTI-TIP KIT 6724 4-3/4 x 2-1/8 BACKGUARD 7572 For 30 models White Kit includes bracket and (2) screws BACKGUARD ENDCAPS Replaces #5923, no endcaps required BACKGUARD ENDCAPS 1805F222 Left (shown) 1805F223

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY VLF-CBP (Front Flue) or VLR-CBP (Rear Flue) High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000

More information

J Series Pilot Burners/Y90 Series Inlet Fittings

J Series Pilot Burners/Y90 Series Inlet Fittings Product Bulletin Issue Date September 8, 2008 J Series Pilot Burners/Y90 Series Inlet Fittings J Series Pilot Burners/Y90 Series Inlet Fittings are used with Intermittent Pilot Ignition (IPI) and Standing

More information

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve NEOTHERM Hydronic Boiler NTH Hydronic Boiler Date: Indoor Sizes 285-850 Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment Large LCD display

More information

TECHNICAL SERVICE BULLETIN

TECHNICAL SERVICE BULLETIN INTERNATIONAL, INC. 159 PARIS AVENUE NORTHVALE, NJ 07647 PHONE 201-768-2400 TECHNICAL SERVICE BULLETIN Date: 08/19/05 Number: 2005-03 Subject: KC1000 LOW NOx CONVERSION KIT INSTRUCTIONS Page 1 of 42 1.

More information

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET Technical Data Uncontrolled Emissions Configuration (EG, EL, ELG) 8.4-42.0 MM BTU/H NG; 60-300 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and

More information

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles Low Temperature urners - STICKTITE and PILOTPK Nozzles 1-1.1-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure

More information

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.

More information

ECLIPSE TURBO BLOWERS SERIES SMJ

ECLIPSE TURBO BLOWERS SERIES SMJ Bulletin /0 ECLIPSE TURBO BLOWERS SERIES SMJ High efficiency Heavy gauge steel base and housing Aluminum impellers balanced statically and dynamically Matching air fi lters available Changeable outlet

More information

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP Space Heaters This Parts Listing has been compiled for your benefit. You can be assured your space heater was constructed and designed with quality and performance

More information

BURNER SERVICE MANUAL 37

BURNER SERVICE MANUAL 37 BURNER SERVICE MANUAL 37 BURNER ASSEMBLY #7-00024 #7-00033 #7-00034 #7-00035 19 1 7-0005 Motor 1/5 HP 3450 RPM Cap. 115V/230V 1 7-20554 Motor, 1/5 HP 3450 RPM 115V (7-00024) 1 2 7-21854001 Fan, Burner

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

Data /1/07 Eclipse RatioAir Burners Model RA0040

Data /1/07 Eclipse RatioAir Burners Model RA0040 Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged Minimum input, () Lower inputs may be achieved. Contact factory. Main Gas Inlet

More information

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles Low Temperature Burners - STICKTITE and PILOTPK Nozzles STICKTITE & PILOTPK Flame retention nozzles -.- For open-port firing or open environment firing Provides positive flame retention and stable clean

More information

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS MDEL C/C S IR R STEM LIHT IL TMIZIN FRCED DRFT BURNERS Power Flame s Versatile High Performance ir or Steam tomizing Light il Burner djustable Premix Firing Head Produces optimum fuel/air mixture within

More information

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP Item :A Prep Room NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG-200830-C-PREP Booth Working Dimensions: 20'0 Wide x 8'0 High x 30'0 Working Depth Approx. Booth Overall Dimensions: 20'4 Wide x 8'10

More information

Innovative Reliability for Mobile Power Applications

Innovative Reliability for Mobile Power Applications COMMERCIAL MOBILE GENERATORS Innovative Reliability for Mobile Power Applications Cummins Onan Commercial Mobile Generators The Cummins Onan mission is simple: Design and create the best, most innovative

More information

Rheem Value Series Upflow/Horizontal Gas Furnace

Rheem Value Series Upflow/Horizontal Gas Furnace THIS MODEL Gas Furnaces Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE 80.0% MID HIGH 78% 82% 88%

More information

Pilot Burners. Universal Pilot Burners A /08/12

Pilot Burners. Universal Pilot Burners A /08/12 24/08/12 A124-1 Universal Universal Fit - This pilot burner offers adjustable mounting options, flexible hood orientations and the accessories needed for replacement Universal fittings and compact size

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged

More information

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged

More information

Compressed Air Filtration

Compressed Air Filtration DF Depth Filter / Coalescence Filter / Particle Filter MAIN FEATURES & BENEFITS: Coalescence / particle filter for the retention of oil and water aerosols as well as particles from compressed air or gases

More information

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity

More information

Compressed Air Filtration

Compressed Air Filtration DF Depth Filter / Coalescence Filter / Particle Filter MAIN FEATURES & BENEFITS: Coalescence / particle filter for the retention of oil and water aerosols as well as particles from compressed air or gases

More information

Rheem Value Series Downflow Gas Furnace

Rheem Value Series Downflow Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Value Series Downflow Gas Furnace RGLS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID A.F.U.E.

More information

Upflow, Upflow / Horizontal, Counterflow / Horizontal

Upflow, Upflow / Horizontal, Counterflow / Horizontal Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long

More information

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation PBGII Packaged Gas Burner PBGII-1 Edition 08-11 Many standard and configurable options available to suit a wide variety of applications Choose from three standard fuel manifolds for natural gas and vaporous

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED BOY FURNACE SPECIFICATIS MODEL NO. HEATING CAPACITY TLF1M087C942SA TLR1M087C942SA High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire High Fire Med-High Fire TLF1M087D9V5SA [6] TLR1M087D9V5SA

More information

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL The Riello RDB series of one stage light oil and kerosene burners is available in eleven basic models, with an output ranging from 16,8 to 120 kw, in three different structures. The models are available

More information

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. ) FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and

More information

Low emissions, high performance natural gas burners

Low emissions, high performance natural gas burners -.6- OVENPAK LE Burners Low emissions, high performance natural gas burners Burns any clean fuel gas Operates on low gas supply pressures Provides clean combustion with low NOx and CO levels Compact burner

More information

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB TORCH BURNERS LOW, MEDIUM, AND HIPRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB Revision: 0 BULLETIN 325, 32, 327 2 ET 2 RETB DESCRIPTION Torches are made up in three series LowPressure,

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles -.-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure for STICKTITE and PILOTPK nozzles when fed with an

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

PRESSURIZED STEEL BOILER WITH REVERSED FLAME smoke pipes PRESSURIZED STEEL BOILER WITH REVERSED FLAME OUTPUT RANGE from 340 to 7000 WORKING TEMPERATURE minimum return temperature 55 OPERATION WITH gas or oil fired jet burners MODELS 340 420 510 630

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

Installation- and maintenance instruction BENTOFLEX ST133K

Installation- and maintenance instruction BENTOFLEX ST133K Installation- and maintenance instruction BENTOFLEX ST133K 171 625 37 07-01 178 004 17 TECHNICAL DATA Type designation ST133K Dimensions B 200 258 ø89 54 237 158 295 Burner tube Length of burner tube Incl.

More information

KINEMAX. Medium velocity gas or oil burners

KINEMAX. Medium velocity gas or oil burners KINEMAX Medium velocity gas or oil burners High Temperature Burners - KINEMAX -.- Exit velocities up to 00 km/h (8 m/s) to promote workload heat penetration and better furnace temperature uniformity Operate

More information

TC30 TRANQUILITY BURNER KIT INSTRUCTIONS

TC30 TRANQUILITY BURNER KIT INSTRUCTIONS IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER These instructions are supplementary to the Installation and Operating Instructions supplied with the fi replace and should be kept together.

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G66-496 REV. 5 Supersedes Form No. G66-496 Rev. 4 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG) MODEL NO. THV1C072A948SA (BECKETT AFG) THV1C072A9V4SA (BECKETT AFG) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

H15 Series BASO Automatic Shutoff Pilot Gas Valve

H15 Series BASO Automatic Shutoff Pilot Gas Valve Bulletin Issue Date June 5, 2017 H15 Series BASO Automatic Shutoff Pilot Gas The H15 Series pilot valves provide safe lighting and complete shutoff of pilot and main burner gas in the event that the flame

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes Info 110 4/98 RatioMatic Burners RM Series version 1.01 50 through 600 Sizes 750 through 2000 Sizes For Ratiomatic Serial Numbers 95-5500 and Above Version 1.01 7/97 Contents 1.0 Operating Parameters &

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000

More information

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change 4 Parts To Your Door Repair Parts Trade Price List (R-18) Effective June 1, 2018 Description Quantity Required 1 Ignition Electrode KIT includes Gasket, Hardware, and Cable 1 54835 $75 2 Sensor Electrode

More information

243 Service Regulators. Outlet Pressure Ranges and Springs. Basic Models. Pipe Size. Temperature Limits. Buried Service

243 Service Regulators. Outlet Pressure Ranges and Springs. Basic Models. Pipe Size. Temperature Limits. Buried Service BR-G-REG-1306-0313-01-A* Model 243 Service Regulators Construction and Design Features 243 Service Regulators These large capacity service regulators are designed and built for commercial, industrial,

More information

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace Gas Furnaces Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace U802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for

More information

SERVICE INSTRUCTIONS KEATING keatingofchicago.com

SERVICE INSTRUCTIONS KEATING keatingofchicago.com SERVICE INSTRUCTIONS 1-800-KEATING keatingofchicago.com FIELD REPLACEMENT KIT - for replacing Flame Switch 037406 and Hardware with Spark Ignition Module For use on all 14" rear drain and all larger size

More information

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace RGPT- Series 80% A.F.U.E. Input Rates 50-125 kbtu ENER UIDE Annual Fuel Utilization Efficiency

More information

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces THIS MODEL 78% 82% 88% 92.0% 97% Air Gas Furnaces Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces RGPQ- Series 80% A.F.U.E. Models with Input Rates from 45-105 kbtu (U.S. & Canadian Models)

More information

H15 Series BASO Automatic Shutoff Pilot Gas Valve

H15 Series BASO Automatic Shutoff Pilot Gas Valve Product Bulletin Issue Date February 11, 2008 H15 Series BASO Automatic Shutoff Pilot Gas The H15 Series pilot valves provide safe lighting and complete shutoff of pilot and main burner gas in the event

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

Hollow Cone Spray Nozzles Series

Hollow Cone Spray Nozzles Series Hollow Cone Spray Nozzles Series TANK WASHING HOLLOW CONE APPLICATION Absorption Chemical process engineering Cooling Disinfection Desuperheating Dust control Fire protection Foam destruction Gas treatment

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK -II Gas Page 2153 Design and Application Details OVENPAK -II s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are

More information

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner

More information