13

14

15

16

17 Data /15/07 Eclipse ImmersoJet Burners Model 3 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr) 440, , ,000 Minimum Input (Btu/hr) 28,000 28,000 28,000 Air Inlet Pressure Input Air pressure at burner inlet (Tap "A") Blower Motor Horse Power.33.5 As Specified Main Gas Pressure ("w.c.) into regulator Max. Min Tube Backpressure ("w.c.) Weight-less actuator (lbs) CO emissions (ppm) <100 <100 <100 Piping Flame Detection Fuel (1) N.P.T. or B.S.P. Flamerod or U.V. Scanner. Natural gas, Propane, Butane For any other mixed gas, contact Eclipse for orifice sizing. (1) Different fuels require different nozzles and orificies. All information is based on laboratory testing with a tube effective length of 22 feet. Different tube sizes and conditions may affect the data. All information is based on standard tube design. Changes in the tube will alter performance and pressures. All inputs based upon gross caloric values. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Plumbing of air and gas will affect accuracy of orifice readings. All information is based on generally acceptable air and gas piping practices.

18 Performance Data 200 Typical Operational Curve & Ignition Zone (Nat. Gas, Propane & Butane) % Excess Air 100 Ignition Zone Operational Curve % 50% 75% Input as a percentage from low fire to high fire Low Fire 28,000 Btu/hr. (Regardless of Blower) High Fire: 440,000 Btu/hr (6" w.c. Blower) 550,000 Btu/hr (10" w.c. Blower) 850,000 Btu/hr (Remote Blower) 18 Gas Orifice P vs. Input Measured from Tap "B" to Tap "D" 14 Air Orifice P vs. 3% O2 Measured from Tap "A" to Tap "C" Pressure Drop ("wc) Natural Gas Propane Gas Butane Gas Pressure Drop ("wc) Natural Gas Propane Gas Butane Gas Input x1000 Btu/hr Input x1000 Btu/hr. 2 Eclipse Model 3 IJ, v2, Data 330-3, 9/15/07

19 775 (30.5) Dimensions & Specifications Dimensions in mm (inches) B D Filter/silencer option shown in gray. A C 1" NPT or BSP (Gas Inlet) 120 (4.72) A 428 (16.85) 301 (11.84) Note: See Remote Blower drawing below for Tap locations. View A A ø200 (7.87) ø230 (9.06) Flame Rod 42 (1.65) Spark Rod 352 (13.84) To Gas Inlet C L A 6 (.236) Adapter to tank wall (4) Max. 45 o 4X90 o 68 (2.7) ø86.5 (3.41) 4x ø12 (.47) Low Pressure Blower High Pressure Blower B A 60Hz 50 Hz C D 324 (12.74) 353 (13.88) 291 (11.44) 291 (11.44) 234 (9.20) 255 (10.02) 638 (25.08) 698 (27.45) 430 (16.91) 490 (19.27) 1" NPT or BSP (Gas Inlet) SQ. (3.81) Tap "B" Remote Blower 2-1/2" NPT or BSP Air Inlet Tap "A" Tap "C" 289 (11.37) 92.8 (3.65) 169 (6.65) Tap "D" 120 (4.72) 428 (16.85) See above drawing for Spark and Flame Rod dimension details (15.78) Eclipse Model 3 IJ, v2, Data 330-3, 9/15/07 3

20 Data /15/07 Eclipse ImmersoJet Burners Model 4 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr) 830,000 1,000,000 1,800,000 Minimum Input (Btu/hr) 100, , ,000 Air Inlet Pressure Input Air pressure at burner inlet (Tap "A") Blower Motor Horse Power As Specified Main Gas Pressure ("w.c.) into regulator Max. Min Tube Backpressure ("w.c.) Weight-less actuator (lbs) CO emissions (ppm) <100 <100 <100 Piping Flame Detection Fuel (1) N.P.T. or B.S.P. Flamerod or U.V. Scanner. Natural gas, Propane, Butane For any other mixed gas, contact Eclipse for orifice sizing. (1) Different fuels require different nozzles and orificies. All information is based on laboratory testing with a tube effective length of feet. Different tube sizes and conditions may affect the data. All information is based on standard tube design. Changes in the tube will alter performance and pressures. All inputs based upon gross caloric values. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Plumbing of air and gas will affect accuracy of orifice readings. All information is based on generally acceptable air and gas piping practices.

21 Performance Data 200 Typical Operational Curve & Ignition Zone (Nat. Gas, Propane & Butane) % Excess Air 100 Ignition Zone Operational Curve % 50% 75% Low Fire 100,000 Btu/hr. (Regardless of Blower) Input as a percentage from low fire to high fire High Fire: 830,000 Btu/hr (6" w.c. Blower) 1,000,000 Btu/hr (10" w.c. Blower) 1,800,000 Btu/hr (Remote Blower) 16 Gas Orifice P vs. Input Measured from Tap "B" to Tap "D" 12 Air Orifice P vs. 3% O2 Measured from Tap "A" to Tap "C" 14 Natural Gas 10 Natural Gas 12 Propane Gas Propane Gas Pressure Drop ("wc) Butane Gas Pressure Drop ("wc) Butane Gas Input x1000 Btu/hr Input x1000 Btu/hr. 2 Eclipse Model 4 IJ, v2, Data 330-4, 9/15/07

22 775 (30.5) Dimensions & Specifications Dimensions in mm (inches) B D Filter/silencer option shown in gray. C A A 1-1/2" NPT or BSP Gas Inlet 491 (19.3) 309 (12.2) Note: See Remote Blower drawing below for Tap locations. View A A Flame Rod 39 (1.5) Spark Rod 147 (5.79) (16.54) To C L Gas Inlet A 12 (.472) Adapter to tank wall (4) Max. 87 (3.4) Low Pressure Blower High Pressure Blower B A 60Hz 50 Hz C D 374 (14.70) 404 (15.88) 315 (12.38) 348 (13.68) 263 (10.34) 304 (11.95) 725 (28.50) 786 (30.90) 452 (17.77) 512 (20.13) Remote Blower 1-1/2" NPT or BSP Gas Inlet 110 SQ (4.33) Tap "D" 491 (19.3) Tap "B" 3" NPT or BSP Air Inlet Tap "C" 345 (13.58) 147 (5.79) See above drawing for Spark and Flame Rod dimension details. 100 (3.94) Tap "A" 509 (20.03) 198 (7.8) Eclipse Model 4 IJ, v2, Data 330-4, 9/15/07 3

23 Data /15/07 Eclipse ImmersoJet Burners Model 6 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 10"w.c. Packaged (60Hz) 15"w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr) 2,000,000 2,500,000 3,600,000 Minimum Input (Btu/hr) 300, , ,000 Air Inlet Pressure Input Air pressure at burner inlet (Tap "A") Blower Motor Horse Power As Specified Main Gas Pressure ("w.c.) into regulator Max. Min Tube Backpressure ("w.c.) Weight-less actuator (lbs) CO emissions (ppm) <100 <100 <100 Piping Flame Detection Fuel (1) N.P.T. or B.S.P. Flamerod or U.V. Scanner. Natural gas, Propane, Butane For any other mixed gas, contact Eclipse for orifice sizing. (1) Different fuels require different nozzles and orificies. All information is based on laboratory testing with a tube effective length of 50.4 feet. Different tube sizes and conditions may affect the data. All information is based on standard tube design. Changes in the tube will alter performance and pressures. All inputs based upon gross caloric values. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Plumbing of air and gas will affect accuracy of orifice readings. All information is based on generally acceptable air and gas piping practices.

24 Performance Data % Excess Air Typical Operational Curve & Ignition Zone (Nat. Gas, Propane & Butane) Ignition Zone Operational Curve % 50% 75% Input as a percentage from low fire to high fire Low Fire 300,000 Btu/hr. (Regardless of Blower) High Fire: 2,000,000 Btu/hr (Low Pressure Blower) 2,500,000 Btu/hr (High Pressure w.c. Blower) 3,600,000 Btu/hr (Remote Blower) 18 Gas Orifice P vs. Input Measured from Tap "B" to Tap "D" 9 Air Orifice P vs. 3% O2 Measured from Tap "A" to Tap "C" Pressure Drop ("wc) Nat. Gas Propane Butane Pressure Drop ("wc) Nat. Gas Propane Butane Input x1000 Btu/hr Input x1000 Btu/hr. 2 Eclipse Model 6 IJ, v2, Data 330-6, 9/15/07

25 1016 (40) 259 (10.2) Dimensions & Specifications Dimensions in mm (inches) D Filter/silencer option shown in gray. A C A 1.5" NPT or BSP Gas Inlet 491 (19.3) Note: See Remote Blower drawing below for Tap locations. ø167.5mm (6.59") View A A 8 x 45 o 22.5 o 294 (11.57) B o/ 328mm (12.91") 8 x o/ 12mm o/ 360mm (0.47") (14.17)" Flame Rod 31 (1.2) Spark Rod 80 (3.1) Low pressure blower High pressure blower 211 (8.31) A 508mm (20.00") 533mm (20.98") 676 (26.61) B 60 HZ 50 HZ 330mm (12.99") 362mm (14.25") 560 (22.05) To C LGas Inlet 306mm (12.04") 320mm (12.60") C 958mm (37.71") 1013mm (39.88") A 12 (.472) Adapter to tank wall (4) Max. D 545mm (21.45") 604mm (23.78") 1.5" NPT or BSP Gas Inlet Tap "C" 4" NPT or BSP Air Inlet Remote Blower Tap "A" Tap "D" 342mm (13.46") 126mm (4.96") Tap "A" Tap "B" See above drawing for Spark and Flame Rod dimension details. 211mm (8.31") 491 (19.3) 211 (8.3) 676mm (26.61") Eclipse Model 6 IJ, v2, Data 330-6, 9/15/07 3

26

27

28

29

30

31

32

33

34

35

36

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750 Main Specifications - RA0750 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged 50Hz Packaged Minimum input, Btu/hr (kw) Lower inputs may be achieved. Contact

More information

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000 Main Specifications - RA1000 PARAMETER Maximum input, Btu/hr (kw) at neutral chamber conditions. (Natural Gas) 60Hz Packaged Blower 50Hz Packaged Blower Minimum input, Btu/hr (kw) Lower inputs may be achieved.

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Data 115-1 10/1/07 Eclipse RatioAir Burners Main Specifications - RA0 PARAMETER Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire

More information

Data /1/07 Eclipse RatioAir Burners Model RA0040

Data /1/07 Eclipse RatioAir Burners Model RA0040 Maximum input, () at neutral chamber conditions 60Hz Packaged Maximum input, () at neutral chamber conditions 50Hz Packaged Minimum input, () Lower inputs may be achieved. Contact factory. Main Gas Inlet

More information

Eclipse Vortometric Burners Series HI

Eclipse Vortometric Burners Series HI Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas)

More information

VALUPAK. Packaged gas burners

VALUPAK. Packaged gas burners VALUPAK Packaged gas burners 1-1.5-1 E - i - 11/14 High turndown. Available in 6 sizes. Capacities: 0.007 MBtu/hr - 4 MBtu/hr. Stable and clean combustion. Suitable for UV scanner and flame rod. Natural

More information

Capacities and Operating Data

Capacities and Operating Data CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000

More information

Design and Application Details

Design and Application Details LO-NOX Line Burners Page 5803 Design and Application Details Total heat release and LO-NOX Burner footage are normally selected from the tables given in the Series HG Mixing Tube section of the Maxon catalog

More information

VALUPAK. Packaged gas burners

VALUPAK. Packaged gas burners VALUPAK Packaged gas burners Low Temperature Burners - VALUPAK 1-1.5-1 High turndown. Available in 6 sizes. Capacities: 2 kw -1124 kw (HHV). Stable and clean combustion. Suitable for UV scanner and flame

More information

North American 4485 Tempest SE

North American 4485 Tempest SE Combustion North American 4485 Tempest SE Medium/High Velocity Gas Burner Low NOx gas burner, durable construction and flexible desgin to fit a variety of applications. NPT or BSP air/gas inlets, adjustable

More information

Eclipse Single-Ended Radiant Tube Burners

Eclipse Single-Ended Radiant Tube Burners 325 Design Guide 3/8/2011 Eclipse Single-Ended Radiant Tube Burners Models SER450, SER600, & SER800 Version 5 Metallic Ceramic Copyright Copyright 2007 by Eclipse, Inc. All rights reserved worldwide. This

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK -II Gas Page 2153 Design and Application Details OVENPAK -II s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are

More information

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures

More information

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET PROFIRE V SERIES TEHNIA DATA INFORMATION PAKET Technical Data Uncontrolled Emissions onfiguration (VG, V, VG) 1.3-16.8 MM BTU/H NG; 9.3-120 GPH #2 OI U listed with choice of NFPA, SD-1, GAP, and FM for

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign 3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot

More information

Low emissions, high performance natural gas burners

Low emissions, high performance natural gas burners -.6- OVENPAK LE Burners Low emissions, high performance natural gas burners Burns any clean fuel gas Operates on low gas supply pressures Provides clean combustion with low NOx and CO levels Compact burner

More information

GEMINI GAS CONTROL PRODUCT INFORMATION

GEMINI GAS CONTROL PRODUCT INFORMATION GEMINI GAS CONTROL PRODUCT INFORMATION The Gemini (6G) combination gas control valve is a versatile multifunction control designed to meet the requirements for use with non-piloted intermittent ignition

More information

2.0 Burner Operating Parameters and Requirements

2.0 Burner Operating Parameters and Requirements ECLIPSE INFORMATION GUIDE Silicon Carbide Radiant Auto-Recupes Info 322 2/99 WARNING Handle silicon carbide tubes carefully. Do not drop them or hammer on them. Although they feature excellent mechanical

More information

KINEMAX. Medium velocity gas or oil burners

KINEMAX. Medium velocity gas or oil burners KINEMAX Medium velocity gas or oil burners High Temperature Burners - KINEMAX -.- Exit velocities up to 00 km/h (8 m/s) to promote workload heat penetration and better furnace temperature uniformity Operate

More information

MULTIFIRE. High temperature dual fuel burner

MULTIFIRE. High temperature dual fuel burner MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,

More information

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB TORCH BURNERS LOW, MEDIUM, AND HIPRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB Revision: 0 BULLETIN 325, 32, 327 2 ET 2 RETB DESCRIPTION Torches are made up in three series LowPressure,

More information

TriOx Triple Air Staged Ultra Low NOx Burner

TriOx Triple Air Staged Ultra Low NOx Burner Triple Air Staged Ultra Low NOx Burner TriOx-1 Edition 09-08 Ultra low NOx emissions of 20 ppm or less Invisiflame mode offers positive UV flame supervision throughout entire operating range for excellent

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2153 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

M SERIES TECHNICAL DATA INFORMATION PACKET

M SERIES TECHNICAL DATA INFORMATION PACKET M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical

More information

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH Info 140 11/4/03 ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower

More information

PT-M90 Automatic Full-Sequence Modulation Gas Control System

PT-M90 Automatic Full-Sequence Modulation Gas Control System PT-M90 PT-M90 Automatic Full-Sequence Modulation Gas Control System PT-M90 Module System Illustration Pucada.Tech M901-0316 Gas Valve (PT-V1C-with step motor) A Profile Dimension: Length(84mm) * Width(40mm)

More information

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110 NOTES: Burner Capacity Information, BBC 111/211 NATURAL GAS, AMBIENT COMBUSTION AIR OPERATION, LOW PRESSURE ATOMIZATION Capacity (at 1% Excess Air) Gas Inlet Pressure Flame Length (at 1% Excess Air) Flame

More information

LVDT/HC PILOT BURNER. External raw gas pilot burner

LVDT/HC PILOT BURNER. External raw gas pilot burner 4-22.4-1 LVDT/HC PILOT URNER External raw gas pilot burner Stable pilot flame in combination with MXON IRFLO LV, HC, DELT-TE and COMUSTIFUME burners Rugged design urns natural gas, propane and LPG Suitable

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,

More information

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes Info 110 4/98 RatioMatic Burners RM Series version 1.01 50 through 600 Sizes 750 through 2000 Sizes For Ratiomatic Serial Numbers 95-5500 and Above Version 1.01 7/97 Contents 1.0 Operating Parameters &

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data

More information

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS LOW EMIION, HIGH PERFORMANCE GA BURNER TECHNICAL CATALOG Fuel and air pressures for the burner are balanced (always equal). This unique design provides simple operation and adjustment throughout the operational

More information

North American 4575 HiRAM

North American 4575 HiRAM Combustion North American 4575 HiRAM The quality and performance of our Tempest, but bigger. Low NOx burner High Velocity - High Turndown Inputs to 4-25 million Btu/hr Direct Spark or Pilot Lighting Furnace

More information

Specifications of OPTIMA SLS Burners

Specifications of OPTIMA SLS Burners 1.1.9-4 Low emperature urners - PIM L pecifications of PIM L urners ypical burner data Fuel: natural gas at 60 F with 1000 tu/ft 3 (st) HH - sg = 0.6 (1) ombustion air: 60 F - 21% 2-50% humidity - sg =

More information

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER CAPABILITIES Industry leading low NOx emissions High momentum. luminous flames at all furnace temperatures High release rates with moderate main combustion air pressure Good turndown with flame characteristics

More information

36H Gas Control Product Information

36H Gas Control Product Information Single Stage 36H Two Stage 36H 36H Gas Control Product Information The 36H combination gas control valve is a versatile multifunction control designed to meet the requirements for use with intermittent

More information

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET Technical Data Uncontrolled Emissions Configuration (EG, EL, ELG) 8.4-42.0 MM BTU/H NG; 60-300 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and

More information

Economite RE Series. Power Gas Burners. MADE in the USA

Economite RE Series. Power Gas Burners. MADE in the USA Economite RE Series MADE in the USA Economite RE 4000 Series MADE in the USA Midco s Economite Family of Burners Backed by 60 Years of Experience 4.00" 6.00" 12.00" RE 4400DS 9.00" 15.75" 20.50" 8.44"

More information

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications. PROFIRE xl Series burners 37.8 TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications. Innovative Technology. Superior performance a technician can trust. The ProFire XL series,

More information

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Industrial Combustion offers complete boiler

More information

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles Low Temperature urners - STICKTITE and PILOTPK Nozzles 1-1.1-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure

More information

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility -.9- KINEDIZER LE High capacity low NOx gas burners Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility Lower NOx and less excess air than standard KINEDIZER

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948

More information

Assembly Numbers. For these products, please order per the following product numbers: (configured products are those with alphanumeric text)

Assembly Numbers. For these products, please order per the following product numbers: (configured products are those with alphanumeric text) Series 67 TUBE-O-FLAME Burners Page 2200-A/P-1 For these products, please order per the following product numbers: (configured products are those with alphanumeric text) Size Packaged Burner 6-08 608 TOF

More information

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. PROFIRE D Series burners 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Cleaver-Brooks offers complete boiler

More information

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS LOW EMIION, HIGH PERFORMANCE GA BURNER TECHNICAL CATALOG Fuel and air pressures for the burner are balanced (always equal). This unique design provides simple operation and adjustment throughout the operational

More information

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

X4 Installation and Operation Manual - POWER FLAME INCORPORATED 7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice

More information

S1 SERIES TECHNICAL DATA INFORMATION PACKET

S1 SERIES TECHNICAL DATA INFORMATION PACKET S1 SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions S1G, S1L, S1LG Technical Data Sheet...3 Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions S1E, S1EG Technical

More information

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. CMC1-50D36 (DV3) CMC1-75D36 (DV3) HEAT INPUT RATE (BTUH) 50,000 75,000 OUTPUT (BTUH)

More information

1470 SERIES HOT AIR GAS BURNER

1470 SERIES HOT AIR GAS BURNER 1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light

More information

1466 SERIES COLD AIR GAS/OIL BURNER

1466 SERIES COLD AIR GAS/OIL BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light wall construction FEATURES

More information

IMMERSION FIRED HOT WATER BOILER

IMMERSION FIRED HOT WATER BOILER 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series

More information

Makotherm Thermal / Catalytic Oxidizer Operation and Maintenance Manual

Makotherm Thermal / Catalytic Oxidizer Operation and Maintenance Manual Makotherm Thermal / Catalytic Oxidizer Operation and Maintenance Manual GENERAL INFORMATION FOR UNIT The Thermal / Catalytic Oxidizer with a Blower Package is used for the remediation of soils with volatile

More information

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. ) FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and

More information

36C and 36D Gas Control Product Information

36C and 36D Gas Control Product Information 6C and 6D Gas Control Product Information The 6C and 6D combination gas control valves are compact multifunction controls designed to meet requirements for use with Standing Pilot systems and all types

More information

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation PBGII Packaged Gas Burner PBGII-1 Edition 08-11 Many standard and configurable options available to suit a wide variety of applications Choose from three standard fuel manifolds for natural gas and vaporous

More information

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry 4-22.4-4 Specifications of LVDT/HC-pilot burner Typical burner data 15 C 21 % O 2 combustion air 50 % humidity natural gas with 10.9 kwh/m³(st) HHV - sg = 0.6 [1] Stated pressures are indicative - actual

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

LP BURNER SERIES.

LP BURNER SERIES. LP BURNER SERIES The Limpsfield LP burner series is characterised by a monoblock structure meaning all necessary components can be combined into a single unit, making installation and set-up easier and

More information

Specifications of MAXON VALUPAK burners for 50 Hz operation

Specifications of MAXON VALUPAK burners for 50 Hz operation 1-1.5-7 Specifications of MAXON VALUPAK burners for 50 Hz operation Capacity data in kw Gross heating value = 10.9 kwh/m 3 (st), d = 0.6. All figures are for balanced - 0 mbar - duct pressure VALUPAK size

More information

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS MDEL C/C S IR R STEM LIHT IL TMIZIN FRCED DRFT BURNERS Power Flame s Versatile High Performance ir or Steam tomizing Light il Burner djustable Premix Firing Head Produces optimum fuel/air mixture within

More information

Performance Selection Data

Performance Selection Data Series "NP" & "RG" AIRFLO Burners Page 5505 Performance Selection Data Operation in shaded area requires special considerations Optimum Design Area Operation in shaded area requires special considerations

More information

APX Nozzle-mix line burner

APX Nozzle-mix line burner Duct urners - PX urners 1 E-i-03/16 PX Nozzle-mix line burner Nozzle-mixing line burner for use with low pressure natural gas, propane and butane Eliminates leakage with its single-piece, aluminum extrusion

More information

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Models MD-25-OG MD-7500-OG December 2012 Copyright 2012 Periflame, Design Guide 113 Industrial Dual-Fuel Burners, 12/01/2012

More information

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH) 1 SEASONAL EFFICIENCY 2 LARGEST REC A/C 3 FUEL

More information

Specifications of STICKTITE and PILOTPAK Nozzles

Specifications of STICKTITE and PILOTPAK Nozzles -.-5 Specifications of STICKTITE and PILOTPK Nozzles This graph indicates the relationship between capacity and applied mixture differential pressure for STICKTITE and PILOTPK nozzles when fed with an

More information

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles Low Temperature Burners - STICKTITE and PILOTPK Nozzles STICKTITE & PILOTPK Flame retention nozzles -.- For open-port firing or open environment firing Provides positive flame retention and stable clean

More information

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING HIGH EFFICIENCY BURNER ASSEMBLY HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING This manual must be read in its entirety before installation of this burner. Installation must be performed by a

More information

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP Space Heaters This Parts Listing has been compiled for your benefit. You can be assured your space heater was constructed and designed with quality and performance

More information

7. SERVICING AND COMPONENT ADJUSTMENTS

7. SERVICING AND COMPONENT ADJUSTMENTS 7. SERVICING AND COMPONENT ADJUSTMENTS General Information on Internal Bypass Oil Systems 1. The system is designed to use 300 PSI pressure at the nozzle inlet at low and high fire (and throughout the

More information

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm) RP Series Regulators Introduction The RP Series regulators are direct-operated with non-balanced trim. Normally they are fitted with a built-in filter. They are produced in the following versions: Types

More information

Start-up Instructions

Start-up Instructions RadMax Burners Page 400-S- Start-up Instructions Read complete instructions before proceeding and familiarize yourself with all the system s equipment and components. Verify that all equipment has been

More information

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Product Bulletin Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve The G196 Series valves use the reliable valve body and magnetic operators from

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY VLF-CBP (Front Flue) or VLR-CBP (Rear Flue) High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000

More information

1200 SERIES FTR HOT AIR BAFFLE BURNER

1200 SERIES FTR HOT AIR BAFFLE BURNER CAPABILITIES High release rates with moderate air pressure Good turn down with flame characteristics and direction maintained Stable flames tailored to the job applications can be from highly oxidizing

More information

BLOC U A-12G BLOC U C-12G

BLOC U A-12G BLOC U C-12G 3.3- INJECTOR BLOCKS AND ORIFICES 3.3.1- INJECTOR BLOCKS WITHOUT IGNITION AND WITHOUT FLAME SAFETY BLOC U-0-000-000-00-A-12G...3.3.1.1 BLOC U-0-000-000-00-C-12G...3.3.1.2 Related sections : Burners...3.2

More information

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction BBG Gas Beta Burner BBG-1 Edition 02-08 BBG shown with pilot ignition and converging tile options. Designed for low pressure air operation Rugged heavy gauge steel construction Alloy or refractory tile

More information

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity

More information

Gas Conversion Kits and Instructions

Gas Conversion Kits and Instructions General and Warnings FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Leave the building immediately.

More information

Pilot Capacities/Specifications

Pilot Capacities/Specifications s Page 9505 Capacities/Specifications Maxon offers a wide range of gas pilots to meet the specific needs of each of its burner product lines. In most cases, the appropriate burner catalog section will

More information

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications Bulletin 71.1 D103087X012 Type HSR December 2017 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications High Capacity Compact Design P1524_1 High Capacity Internal

More information

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION SF-200 OCTOBER 10, 2016 SureFire II TM Pilot Forced Draught Gas Pilot type SP-32-xx-FD Instruction Manual 1. INTRODUCTION This Instruction Manual contains a description of the type SP-32-xx-FD gas pilot

More information

MAXON OVENPAK LE. Low emissions, high performance gas burners. Technical Catalog

MAXON OVENPAK LE. Low emissions, high performance gas burners. Technical Catalog MXON OVENPK LE Low emissions, high performance gas burners Technical Catalog TBLE OF CONTENT Features & Benefits... Product description... Typical applications... Typical emissions... Intelligent Model

More information

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies: Airejet Low NOx Coal Burner Unique low NO X coal burner with center air jet for use with overfire air (OFA) systems. Sleeve Damper Actuator Core Air Inlet Duct and Damper Pitot Grid Outer Spin Vanes Inner

More information

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) MP GS/GD Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com Page 2 Moisture + MP-GS/GD DESCRIPTION PAGE Deluxe Control Panel 4 Standard

More information

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1 Gas Limiting Orifice Valve Features Precision machined valve flow piston Rugged cast iron body Replaceable cartridge assembly for LVG 55-5 Straight through valve design; right angle valve option Pressure

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

Burner Selection Criteria

Burner Selection Criteria UNI-RAD Radiant Tube Burners Page 4803 Burner Selection Criteria Combustion Air View Port/Optic Flame Sensor Mount Gas Inlet 3"- 4" Burner Selection The UNI-RAD Burner can be used with various radiant

More information

INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS

INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS CU-21 MAY 5, 2008 INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS APPLICATION The FIREYE fiber optic scanners have been designed for installation on burners

More information

DEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc.

DEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc. DEXEN INDUSTRIES Inc. GENERAL CATALOG DEXEN INDUSTRIES Inc. 6003 GAS VALVES 6003-series gas valve is an effective and reliable gas valve for low-btu gas product and application. The product is most commonly

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

CHALLENGER Propane to Natural Gas Instructions

CHALLENGER Propane to Natural Gas Instructions Kit Part Number: CCRKIT02 Kit Includes: - Rating Label - (3) Natural Gas Orifices - T-15 Torx Wrench Recommended Tools: - Phillips-Head Screwdriver - Standard Adjustable Wrenches - Calibrated Combustion

More information

The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor

The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor OPERATIONS MANUAL The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor KEY FEATURES Strong, Reliable Ignition & Pilot Flame Rapid Flame Response LED Flame Status Indicator Fully

More information

Applies to: Models F, B, FE, and BE with spark pilot

Applies to: Models F, B, FE, and BE with spark pilot Form CP-F/B-GC (11/17) R8 Obsoletes Form CP-F/B-GC (Version A.2) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE with spark pilot NOTE: Units with standing (match - lit) pilots

More information