Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency

Size: px
Start display at page:

Download "Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency"

Transcription

1 Gas Furnaces PRODUCT SPECIFICATIONS INSTALLATION OPTIONS A vailable in Upflow/Horizontal and Counterflow models 80% AFUE 44,000 to 32,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER A luminized steel tapered design primary heat exchanger with crimped construction for long life BURNERS Upflow / Horizontal A luminized steel inshot burners for smooth combustion CABINET CONSTRUCTION Unitized construction for cabinet integrity Bottom or side return air Baked on pre-painted steel cabinet finish Left or right side gas and electric entry Less than 2% air leakage (meets ANSI/ASHRAE Standard ) BLOWER Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency Counterflow CONTROLS Single stage gas valve Integrated ignition and fan control board features self diagnostics Hot surface ignitor VENTING P ermanently lubricated draft motor is air cooled for long life L designated units comply with California s South Coast Air Quality Management District Low NOx requirements Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

2 Model Number Identification 80 = AFUE AF = Aire-Flo UH = Upflow / Horizontal DF = Counterflow Heat Input 045 = 45,000 Btuh 070 = 70,000 Btuh 090 = 90,000 Btuh 0 = 0,000 Btuh 35 = 35,000 Btuh Specifications - Low Nox = -Stage UH045P2A UH045P2AL 80 AF UH 0 P 20 C L UH070P2A UH070P2AL UH090P2B UH090P6B UH090P6BL L = Low NO x Cabinet Width A = 4-/2 in. B = 7-/2 in. C = 2 in D = 24-/2 in. Nominal Airflow 08 = 800 cfm 2 = 200 cfm 6 = 600 cfm 20 = 2000 cfm P = PSC Direct Drive Blower Motor UH0P6C UH0P20C UH0P20CL Upflow / Horiz. Upflow / Horiz. Upflow / Horiz. Upflow / Horiz. Upflow / Horiz. Upflow / Horiz. Input Btuh 44,000 66,000 88,000 88,000 0,000 0,000 Output Btuh 35,000 54,000 7,000 7,000 89,000 89,000 AFUE (Isolated Comb. System) 80% 80% 80% 80% 80% 80% Temperature Rise ( F) Gas Pipe Size (in.) /2 /2 /2 /2 /2 /2 Flue Connection in. (diameter) Volts/Hertz/Phase 20/60/ 20/60/ 20/60/ 20/60/ 20/60/ 20/60/ Blower Motor Horsepower /3 /3 /3 /2 /2 Add-On Cooling (tons) Circuit Breaker or Fuse Full Load Amps Blower Wheel Size (Dia. x Width) 0 x 8 0 x 8 0 x 9 0 x 0 0 x 0 ½ x 0 Shipping Weight (lbs.) Specifications UH35P20D DF045P2A DF070P2A DF090P6B DF0P20C Upflow / Horiz. Counterflow Counterflow Counterflow Counterflow Input Btuh 32,000 44,000 66,000 88,000 0,000 Output Btuh 07,000 35,000 54,000 7,000 89,000 AFUE (Isolated Comb. System) 80% 80% 80% 80% 80% Temperature Rise ( F) Gas Pipe Size (in.) /2 /2 /2 /2 /2 Flue Connection in. (diameter) Volts/Hertz/Phase 20/60/ 20/60/ 20/60/ 20/60/ 20/60/ Blower Motor Horsepower /3 /3 /2 Add-On Cooling (tons) Circuit Breaker or Fuse Full Load Amps Blower Wheel Size (Dia. x Width) x 0 x 8 0 x 8 0 x 0 ½ x 0 Shipping Weight (lbs.)

3 Accessories - Upflow / Horizontal UH045P2A UH090P2B UH0P6C UH070P2A UH090P6B UH0P20C UH35P20D Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal CABINET Horizontal Suspension Kit (Horizontal) 5W0 5W0 5W0 5W0 Return Air Base (Upflow) 68W6 68W62 68W63 68W64 FILTER KITS Air Filter and Horizontal (end) 87L95 (4 x 25 x ) 87L96 (8 x 25 x ) 87L97 (20 x 25 x ) 87L98 (25 x 25 x ) Rack Kit (Upflow/Horizontal Side Return Single 44J22 44J22 44J22 44J22 (Upflow) 0-pack 66K63 66K63 66K63 66K63 Size 6 x 25 x 6 x 25 x 6 x 25 x 6 x 25 x GAS HEATING High Altitude Pressure Switch Kit ft. No Change No Change No Change No Change ft. 80W52 (045, 070) 80W52 (090) 80W57 (0) 80W57 (35) 750-0,000 ft. 80W5 (045, 070) 80W5 (090) 80W52 (0) 80W5 (35) Natural to LP Conversion Kit ft. K49 K49 K49 K ,000 ft. K44 K44 K44 K44 LP to Natural Conversion Kit ft. 73W8 73W8 73W8 73W8 Natural Gas High Altitude Orifice Kit 750-0,000 ft. 73W37 73W37 73W37 73W37 NIGHT SERVICE KIT Night Service Kit 68W80 68W80 68W80 68W80 VENTING Vent Adaptor 6 in. conn. size upflow applications only 8M79 8M79 8M79 8M79 Cleanable polyurethane frame type filter. Accessories - Counterflow DF045P2A DF070P2A DF090P6B DF0P20C Counterflow Counterflow Counterflow CABINET Combustible Flooring Base (Counterflow) M59 M60 M6 FILTER KITS Air Filter and Rack Kit (Counterflow) 5W06 (() 20 x 6 x 5W07 (2) 20 x 20 x 5W08 (2) 20 x 20 x GAS HEATING High Altitude Pressure ft. 80W52 (045, 070) 80W52 (090) 80W57 (0) Switch Kit 750-0,000 ft. 80W5 (045, 070) 80W5 (090) 80W52 (0) Natural to LP Conversion Kit ft. K49 K49 K ,000 ft. K44 K44 K44 LP to Natural Conversion Kit ft. 73W8 73W8 73W8 LP High Altitude Orifice Kit 750-0,000 ft. 73W37 73W37 73W37 NIGHT SERVICE KIT Night Service Kit 68W80 68W80 68W80 Cleanable polyurethane frame type filter.

4 Blower Data UH045P2A UH070P2A UH090P2B UH090P6B UH0P6C UH0P20C Single Side Return Air - Air volumes in bold require field fabricated transition to accommodate 20 x 25 x in. air filter in order to maintain proper air velocity. Bottom Return Air, Side Return Air with Optional Return Air Base, Return Air from Both Sides or Return Air from Bottom and One Side. UH35P20D Single Side Return Air - Air volumes in bold require field fabricated transition to accommodate 20 x 25 x in. air filter in order to maintain proper air velocity. Bottom Return Air, Side Return Air with Optional Return Air Base, Return Air from Both Sides or Return Air from Bottom and One Side. Notes: Maximum approved external static pressure is 0.50 in. w.c. Blower External Static Pressure - in w.c. Less Filter Speed High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low

5 Blower Data DF045P2A (Counterflow) DF070P2A (Counterflow) DF090P6B (Counterflow) DF0P20C (Counterflow) Notes: Maximum approved external static pressure is 0.50 in. w.c. Blower External Static Pressure - in w.c. Less Filter Speed High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low Clearance to Combustibles (in.) UPFLOW / COUNTERFLOW POSITION Vent Type Type B Type C Sides 0 0 Rear 0 0 Top Front 2-/4 2-/4 Front (service/alcove) Floor Combustible Combustible Flue (25) 6 (52) NOTE Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI-Z223.). NOTE In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ANSI-Z223.) or applicable provisions of local building codes. Left side requires 4 in. if single wall vent is used on 4-/2 in. cabinets, 2 in. on 7-/2 in. cabinets. HORIZONTAL POSITION Vent Type Type B Type C End 2 2 Rear 0 0 Top 0 0 Front 2-/4 2-/4 Front (service) Floor Combustible Combustible Flue 6 NOTE Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI-Z223.). NOTE In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ANSI-Z223.) or applicable provisions of local building codes. Line contact installation permissible between jacket top or sides and building joists.

6 Dimensions - inches (mm) Upflow 3-/8 (79) NOTE - 20C and 20D size units that require second stage air volumes over 800 cfm (850 L/s) must have one of the following:. Single side return air with transition, to accommodate 20 x 25 x in. (508 x 635 x 25 mm) cleanable air filter. Required to maintain proper air velocity. 2. Single side return air with optional Return Air Base 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Performance Tables for additional information. FLUE OUTLET (Top) D SUPPLY OPENING 2 Flue outlet may be horizontal but furnace must be vented vertically 3 Optional External Side Return Air Filter Kit is not for use with the optional Return Air Base. 3 OPTIONAL EXTERNAL SIDE RETURN FILTER KIT 23- (603) TOP VIEW 25 (635) A B 9/6 (4) (9) Front Panel 3 (76) Right 6- (7) Left 3-/4 (83) 27- (705) 9-7/6 (494) 9/6 (4) 3 OPTIONAL EXTERNAL SIDE RETURN FILTER KIT 33 (838) 9-/8 (232) Right 8-5/8 (29) Left 5-3/8 (37) Right -9/6 (40) Left 2 FLUE OUTLET ELECTRICAL INLET GAS PIPING INLET 4- (375) 6 (406) ELECTRICAL INLET 23 (584) Side Return Air Opening 4 (356) -/2 (38) -5/6 (49) (9) C Bottom Return Air Opening (9) 5/8 (6) 3-/4 (83) 23-/2 (597) Bottom Return Air Opening A B C D in. mm in. mm in. mm in. mm UH045P2A UH070P2A 4-/ / UH090P2B UH090P6B 7-/ / /8 94 UH0P6C UH0P20C / / /8 238 UH35P20D 24-/ / /8 283

7 Dimensions - inches (mm) Horizontal Flue outlet may be from end but furnace must be vented vertically 9-/8 (232) Top 8-5/8 (29) Bottom FLUE OUTLET (Top) 3 (76) LEFT-HAND DISCHARGE GAS PIPING INLET (Top or Bottom) FLOW ELECTRICAL INLET (Top or Bottom) /6 (7) Front Panel Gas Furnaces 27- (705) 9/6 (4) (9) FLUE OUTLET (End) 6- (7) 5-3/8 (37) Top -9/6 (40) Bottom TOP VIEW 33 (838) (9) (9) 27- (705) 9/6 (4) 9-7/6 (494) SUPPLY OPENING B D A FLOW 4-/4 (08) A C 23-/2 (597) RETURN OPENING END VIEW 3-/8 (79) FRONT VIEW RIGHT-HAND DISCHARGE END VIEW ELECTRICAL INLET (Top or Bottom) FLOW GAS PIPING INLET (Top or Bottom) 6- (7) Flue outlet may be horizontal but furnace must be vented vertically FLUE OUTLET (Top) (9) Front Panel 3 (76) -5/8 (4) Top 5-3/8 (37) Bottom TOP VIEW 8 (203) Top 9-/8 (232) Bottom 27- (705) (9) 33 (838) FLUE OUTLET (End) (9) 27-3-/8 (705) (79) 23-/2 (597) RETURN OPENING C 4-/4 (08) A FLOW A D 9-7/6 (494) SUPPLY OPENING B 9/6 (4) END VIEW (9) FRONT VIEW END VIEW 9/6 (4) A B C D in. mm in. mm in. mm in. mm UH045P2A UH070P2A 4-/ / UH090P2B UH090P6B 7-/ / /8 94 UH0P6C UH0P20C / / /8 238 UH35P20D 24-/ / /8 283

8 Dimensions - in. (mm) Counterflow 3-/8 (79) 9/6 (4) D FLUE OUTLET (Top) B RETURN OPENING 9-7/6 (494) 9/6 (4) 9/6 (4) TOP VIEW A B 9/6 (4) (9) Front Panel 27- (705) 9-7/6 (494) 9/6 (4) FLOW 33 (838) 5-3/8 (37) Right 2-/8 (54) Left ELECTRICAL INLET GAS PIPING INLET 6-5/8 (68) Right 7-/8 (8) Left (9) C Supply Air (9) 9-/4 (489) Supply Air (9) FRONT VIEW SIDE VIEW A B C D in. mm in. mm in. mm in. mm DF045P2A DF070P2A 4-/ / DF090P6B 7-/ / /4 59 DF0P20C / /

9

10

11

12 Revisions Sections Product Specifications Description of Change Temperature Rise Ranges updated (/206) Aire-Flo Heating and Cooling, 206

Available in Upflow/Horizontal and Counterflow/Horizontal models

Available in Upflow/Horizontal and Counterflow/Horizontal models PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow/Horizontal models 80% AFUE 50,000 to 25,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER Aluminized steel

More information

Upflow, Upflow / Horizontal, Counterflow / Horizontal

Upflow, Upflow / Horizontal, Counterflow / Horizontal Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long

More information

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized

More information

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized

More information

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 96G1E-100 (04/2018) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless

More information

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains

More information

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING 92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped

More information

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor 80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor A80-1E Form No. A80-1E-100 (10/2011) Features and Benefits CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped

More information

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for

More information

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS 80% Gas Furnace Single Stage - High Efficiency (Constant Torque) Motor 80G1-E Features and Benefits Form No. R80G1-E-100 (11/2011) CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped

More information

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN A951E PRODUCT SPECIFICATIONS SINGLE STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A951E-100 (10/2018) CONTROLS Single stage gas valve Durable silicon nitride ignitor Self diagnostics saves

More information

93% Gas Furnaces Single Stage

93% Gas Furnaces Single Stage Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 93% Gas Furnaces Single Stage Form No. AA931A-100 (05/2012) HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped

More information

AF90. AF90 Gas Furnace High Efficiency. Features

AF90.   AF90 Gas Furnace High Efficiency. Features AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty

More information

Upflow, Upflow / Horizontal, Counterflow

Upflow, Upflow / Horizontal, Counterflow , / Horizontal, 90/92 Gas Furnace CG90/92 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long life AL29-4C Stainless

More information

93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS

93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS 93% Single Stage Gas Furnace Form No. JA931A-100 (08/2010) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped no

More information

A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN

A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE FORM NO. A802V-100 (04/2016) VENTING Rotatable draft inducer for venting flexibility INSTALLATION FEATURES Left and right utility connections

More information

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev. TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose

More information

G60UHV. DAVE LENNOX SIGNATURE COLLECTION Up Flow / Horizontal Two Stage Heat Variable Speed Blower G A S F U R N A C E S

G60UHV. DAVE LENNOX SIGNATURE COLLECTION Up Flow / Horizontal Two Stage Heat Variable Speed Blower G A S F U R N A C E S E N G I N E E R I N G D A T A G A S F U R N A C E S G60UHV DAVE LENNOX SIGNATURE COLLECTION Up Flow / Horizontal Two Stage Heat Variable Speed Blower Bulletin No. 210346 December 2008 Supersedes February

More information

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

Multi-Position, Multi-Speed Gas Furnaces

Multi-Position, Multi-Speed Gas Furnaces Heating Input: 40,000 140,000 BTU/h / Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve control technology allows installer to

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

96% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS

96% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS 96% Modulating Variable Speed Gas Furnace Form No. AA96MV-100 (08/2010) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN 409 stainless steel primary heat exchanger

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE / SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel

More information

G8MVL. Product Specifications

G8MVL. Product Specifications 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in

More information

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h / ADSS8 Heating Input: 40,000 140,000 BTU/h Single-Stage Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...7 Wiring Diagrams...10 Accessories...11

More information

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved

More information

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) C9MVX SoftSound VS90 Product Specifications 95% Variable Speed Two Stage Heating Furnace FLEXIBILITY Supports two stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40in (1016mm)

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11

More information

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h Heating Input: 40,000 140,000 BTU/h /ADSS8 Single-Stage Multi-Speed Gas Furnaces 80% AFUE Standard Features Single-stage gas valve Durable Silicon Carbide ignitor Quiet, single-speed draft inducer Self-diagnostic

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h // Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE / 95%/93% AFUE MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE HEATING INPUT: 46,000 115,000 BTU/H LIFETIME HEAT EXCHANGER LIMITED WARRANTY 10 YEAR HEAT REPLACEMENT CXCHANGER WARRANTY

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h / Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

F8MTL. Product Specifications

F8MTL. Product Specifications 80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Product Data. that this product meets the S 95% AFUE S Two -stage operation DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

N9MPD Product Specifications

N9MPD Product Specifications Single Stage Furnace Multiposition FLEXIBILITY Dual certified venting (1 or 2 pipes) Direct Vent furnace 40 (1016mm) high with wider cabinets, for ease of installation Factory shipped as natural gas, with

More information

97% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS

97% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS 97% Modulating Variable Speed Gas Furnace Form No. AA97MV-100 (05/2012) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN 409 stainless steel primary heat exchanger

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 100,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8

More information

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 45,000 1,000 BTUH The GMS8/GDS8/GHS8 single-stage, multi-speed gas furnaces offer installation versatility.

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity

More information

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE FORM NO. G22-448 REV. 10 Supersedes Form No. G22-448 Rev. 9 GAS FURNACES UGPH- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS

A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE FORM NO. A97MV-100 (06/2014) CONTROLS Communicating control enabled Modulating gas valve Thermostat flexibility: works with the Comfort

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. ) FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

FG7S (C and L Series)

FG7S (C and L Series) TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) FORM NO. G66-544 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE / Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 7 Wiring Diagram... 10 Accessories... 11 Minimum Filter

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different

More information

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-485 REV. 4 Supersedes Form No. G22-485 Rev. 3 GAS FURNACES UGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

ELITE SERIES Multi Position Two Stage Heat Variable Speed Blower

ELITE SERIES Multi Position Two Stage Heat Variable Speed Blower E N G I N E E R I N G D A T A G A S F U R N A C E S G61MPV ELITE SERIES Multi Position Two Stage Heat Variable Blower Bulletin No. 210506 December 2008 Supersedes April 2008 AFUE up to 95.0% Input 44,000

More information

UPFLOW/ HORIZONTAL GAS FURNACE

UPFLOW/ HORIZONTAL GAS FURNACE FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 1 Supersedes Form No. G66-478 Rev. 0 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing line of upflow/horizontal gas furnaces are designed for utility rooms, closets,

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

WFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. F verification of certification f individual products, go to www.ahridirecty.g.

More information

TSTAT0101SC Recommended (sold separately)

TSTAT0101SC Recommended (sold separately) Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

FG7T (E and N Series)

FG7T (E and N Series) TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303) TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION DESCRIPTION These high efficiency, dedicated downflow compact units employ induced

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) VHF-ANP / VHF-ANE (BECKETT NX) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250

More information

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

AKSS92. Single-Stage. Heating Input: 46, ,000 BTU/h. up to 92.1% AFUE

AKSS92. Single-Stage. Heating Input: 46, ,000 BTU/h. up to 92.1% AFUE Heating Input: 46,000 115,000 BTU/h Single-Stage Multi-Speed Gas Furnace up to 92.1% AFUE Standard Features Stainless-steel secondary heat exchanger Single-stage gas valve Durable Silicon Carbide ignitor

More information

ELITE SERIES Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

ELITE SERIES Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower PRODUCT SPECIFICATIONS GAS FURNACES EL96UHV ELITE SERIES Upflow / Horizontal - Two-Stage Heat - Variable Blower Bulletin No. 069 April 05 Supersedes January 05 MODEL NUMBER IDENTIFICATION EL 96 UH 070

More information

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces Heating Input: 40,000 140,000 TU/h //GHS8 Multi-Position, Multi-Speed Gas Furnaces 80% AFUE Standard Features Dual-diameter tubular heat exchanger Single-stage combination redundant gas valve Norton hot

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

G9MXE. Product Specifications

G9MXE. Product Specifications Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal

More information

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction. RPGE13 Product Specifications 13 SEER Gas / Electric Residential Packaged Unit Form No. RPGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

Rheem Classic Series Downflow Gas Furnace

Rheem Classic Series Downflow Gas Furnace Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

Rheem Value Series Upflow/Horizontal Gas Furnace

Rheem Value Series Upflow/Horizontal Gas Furnace THIS MODEL Gas Furnaces Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE 80.0% MID HIGH 78% 82% 88%

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization

More information