80% Oil Furnace Basement - Belt & Direct Drive LBF(R) HEAT EXCHANGER CABINET BLOWER BURNER CONTROLS VENTING INSTALLATION ACCESSORIES WARRANTY

Size: px
Start display at page:

Download "80% Oil Furnace Basement - Belt & Direct Drive LBF(R) HEAT EXCHANGER CABINET BLOWER BURNER CONTROLS VENTING INSTALLATION ACCESSORIES WARRANTY"

Transcription

1 80% Oil Furnace Basement - Belt & Direct Drive LBF(R) HEAT EXCHANGER Heavy-duty 4 gauge steel with a long lasting ceramic fiber combustion chamber Easy access large diameter clean out ports CABINET Foil-faced high density fiberglass insulation reduces heat loss and noise Pre-painted steel for maximum durability Internal filter included BLOWER Direct drive have slide-out design with quick plug-in wiring 4 speed PSC direct drive motors have dynamically balanced blower with resilient motor mounts for smooth and quiet operation Belt drive have permanently lubricated split phase motor, adjustable pulley and sheave BURNER High quality Beckett Flame Retention burner for efficient combustion High efficiency air flow system to provide consistent operation through all operating conditions CONTROLS Honeywell 784B primary control with 5 second prepurge, interrupted ignition, limited reset, and LED diagnostics Solid state igniter with 20kV output voltage PSC motor with low amp draw and ball bearings for long life Clean-cut solenoid pump with positive shut-off Readily available trade components 40 VA transformer (Direct drive only) Color coded wiring for easy service Transformer and cooling fan relay are factory wired for easy add-on cooling installation (Direct drive only) VENTING Includes standard barometric damper Optional sidewall vent kit INSTALLATION Factory wired ACCESSORIES Coil cabinet Cleanout brush kit Combustion air boot WARRANTY Limited life-time on heat exchanger Five year limited on all parts Extended protection plans available C (LBR40/68 & LBR96 not certified in Canada)

2 Model Number Guide L BF 80 C 57/72 D 2-2A L - Oil Revision Code BR-Basement Rear Flue CFM x 00 BF-Basement Front Flue D - Direct Drive 80-80% AFUE B - Belt Drive C - Series Nominal Output 57-57,000 Btuh Physical & Electrical Model Nozzle Input (Btuh) Output (Btuh) AFUE Nom. Cooling Cap. Flue Dia. Filter Volts/Hz/ Phase Max. Time Delay Breaker or Fuse (amp) Trans. (V.A.) Shipping Weight (lb.) LBF80C57/72D2.50GPH-80 o A 70,000 57,000.65GPH-80 o B 90,000 74, x 9 20/60/ LBF80C84/95D6.65GPH-80 o B 05,000 85,000.75GPH-80 o B 9,000 97, x 9 20/60/ LBF80C2/25D20.85GPH-80 o B 40,000 3,000.00GPH-80 o B 54,000 25, x 2 20/60/ LBR80C57/72D2.50GPH-80 o A 70,000 57,000.65GPH-80 o B 90,000 74, x 9 20/60/ LBR80C84/95D6.65GPH-80 o B 05,000 85,000.75GPH-80 o B 9,000 97, x 9 20/60/ LBR80C2/25D20.85GPH-80 o B 40,000 3,000.00GPH-80 o B 54,000 25, x 2 20/60/ LBR80C40/68D20.0GPH-80o B 75,000 40,000.25GPH-80 o B 20,000 68, /8 x 22 7/6 20/60/ LBF80C57B08.50GPH-80 o A 70,000 57, x 9 20/60/ LBF80C84/95B0.65GPH-80 o B 05,000 85, GPH-80 o B 9,000 96, x 9 20/60/ LBF80C2/25B6.85GPH-80 o B 40,000 3, GPH-80 o B 54,000 25, x 2 20/60/ LBR80C57B08.50GPH-80 o A 70,000 57, x 9 20/60/ LBR80C84/95B0.65GPH-80 o B 05,000 85, GPH-80 o B 9,000 97, x 9 20/60/ LBR80C2/25B6.85GPH-80 o B 40,000 3, GPH-80 o B 54,000 25, x 2 20/60/ LBR80C96B24.50GPH-80 o B 245,000 96, /8 x 24 3/8 20/60/ See Table for Alternate s for Cooling Combinations 2 2 Volt heating only. Additional transformer required for cooling applications. NOTE: are rated at 40 psi pump pressure except the LBF/R 57/72 which is rated at 00 psi.

3 Performance - Direct Drive Model (hp) Temp. Rise ( o F) Speed ext. static pressure - in. W.C High,400,350,307,250,87,05, LBF80C57/72D2 /3 0 x Med High,36,30,03,075, Med Low High,760,670,599,550,40,35, LBF80C84/95D6 /2 0 x Med High,603,45,459,394,307,90, Med, ,300,259,88, Low,62,50,30,05, High 2,60 2,080 2,00,969,850,735,627,50 LBF80C2/25D20 3/4 2 x Med High,850,80,744,670,580,50,403,305 Med,650,600,580,490,430,370,30,236 Low,480*,470*,445*,380*,330*,276*,97*,090* High,400,350,307,250,87,05, LBR80C57/72D2 /3 0 x Med High,36,30,03,075, Med Low High,760,670,599,550,40,35, LBR80C84/95D6 /2 0 x Med High,603,45,459,394,307,90, Med, ,300,259,88, Low,62,50,30,05, High 2,22 2,24 2,029,980,835,730,575,54 LBR80C2/25D20 3/4 2 x Med High,85,755,704,625,549,454,350,250 Med,564,525,50,435,369,279,206,4 Low,360*,355*,30*,260*,205*,50*,087* 998* High 2,245 2,38 2,034,985,833,750,690,550 LBR80C40/68D20 3/4 2 x Med High,835,780,729,670,609,523,45,38 Med,620,590,540,490,435,335,269,88 Low,460*,435*,400*,320*,280*,200*,32*,050* *Not recommended for heating. Temperature rise may be outside acceptable range.

4 Performance - Belt Drive Model (hp) Adjustment Belt Temp. Rise ( o F) ext. static pressure - in. W.C. LBF80C57B08 /6 0 x 8 3 /4 Turn LBF80C84/95B0 /4 0 x 8 4 Closed LBF80C2/25B6 3/4 2 x 9 4 Closed LBR80C57B08 /6 0 x 8 3 /4 Turn LBR80C84/95B0 /4 0 x 8 4 Closed LBR80C2/25B6 3/4 2 x 9 4 Closed LBR80C96B24 3/4 2 x 2 6 Closed 3 / Low Fire Nozzle 2 High Fire Nozzle

5 Alternate s for Cooling Combinations - Belt Drive Model Nominal Cooling Capacity Adjustment Belt ext. static pressure - in. W.C LBF80C57B /4 0 x 8 7 Closed 4 4,340*,320*,80,080 LBF80C84/95B /2 0 x 8 6 Closed 4 40,770,680,560,430 LBF80C2/25B /4 2 x 9 5 Closed 3 /4 38 2,050 2,000,930,880 LBR80C57B /4 0 x 8 7 Closed 4 4,260,85,095,000 LBR80C84/95B /2 0 x 8 6 Closed 4 40,600,540,480,400 LBR80C2/25B /4 2 x 9 5 Closed 3 /4 38 2,020,980,90,860 LBR80C96B /4 2 x 2 6 Closed 3 /2 42 2,660 2,575 2,450 2,350 *Not recommended for heating. Temperature rise may be outside acceptable range. Note: Field converted with different size motor for cooling applications.

6 Accessories Description Clean Out Kit Used with Kit Number ABRSH380-3 Tjerlund Side Wall Vent Kit ASVNT522 2 Field Controls Side Wall Vent Kit ASVNT523 Evaporator Evaporator Coil Evaporator Evaporator Evaporator Combustion Clean Coil Cabinet Cabinet Coil Cabinet Coil Cabinet Coil Cabinet Air Kit Out Cap Kit This can be ordered from Tjerlund, part number SSII. 2 This can be ordered from Field Controls, part number SWG-5-CK6. LBF-R57/72/84/95 to U2E24NB, U2E30NB, U2E36BN, U2E46BN AAOILKDCC9 LBF-R8057/72/84/95 to U2E58C & LBF-R2/25 to U2E36C, U2E46C, U2E58C AAOILKDCC22 LBR40/68 to U2E46D, U2E58D AAOILKDCC24 LBR96 to U2E58D AAOILKDCC26 LBF-R2/25 to U2E60D & LBR40/68 & LBR96 to U2E60D AAOILKCDD27 ABOOT57 ACAP570 Evaporator Coil Cabinet Model No. Plenum Cabinet A B C D AAOILKDCC9 8 / 22 / 8 9 / 222 / 8 AAOILKDCC22 2 / 2 22 / 4 22 / 2 23 / 4 AAOILKDCC / / 4 AAOILKDCC / / 8 AAOILKDCC / / 8 (Note: Some coils only have right side drain.)

7 Dimensions Model A B C D E F G H J K LBF80C57/72 LBF80C84/95 9 / /4 2 3 /4 6 /2 52 /8 N/A LBF80C2/25 22 / /4 2 3 /4 6 /2 52 /8 N/A LBR80C57/72 LBR80C84/95 9 / /4 2 3 /4 6 /2 52 /8 27 LBR80C2/25 22 / /4 2 3 /4 6 /2 52 /8 29 LBR80C40/ / /8 2 / /4 29 LBR80C / /2 2 7/6 23 7/8 6 /8 32 Clearances Model Number Front* Sides Rear LBF80C57/72 LBF80C84/95 LBF80C2/25 LBR80C57/72 LBR80C84/95 LBR80C2/25 LBR80C40/68 LBR80C *Clearance from combustibles. 4 D Supply Return Flue Pipe (Front Flue) F E G H A J B 3 /4 C L C 2Ô 5Ô Control Wiring (R side) Flue Pipe (Rear Flue) K 7 2Ô Power Wiring (R side) 6Ð Oil Line (R & L side)

8 42 Monroe Street Bellevue, OH 448 (49) Form #ALBF/R 80C-00 (/03) Armstrong Air Conditioning Inc Printed in U.S.A. *ALBF-R-00-80C--03*

80% Oil Furnace RLBF(R)

80% Oil Furnace RLBF(R) 80% Oil Furnace Basement-Direct & Belt Drive RLBF(R) FEATURES AND BENEFITS Heavy-duty 14 gauge steel heat exchanger with a long lasting ceramic fiber combustion chamber Easy access large diameter clean

More information

L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE VENTING WARRANTY GENISYS ADVANCED BURNER CONTROL CONFIGURATIONS HEAT EXCHANGER CABINET BLOWER BURNER

L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE VENTING WARRANTY GENISYS ADVANCED BURNER CONTROL CONFIGURATIONS HEAT EXCHANGER CABINET BLOWER BURNER L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE FORM NO. L83-100 (07/2014) VENTING Includes field installed barometric damper Optional sidewall vent kit available WARRANTY 10 year limited parts warranty / lifetime

More information

83% Oil Furnace. Features. Configurations. Cabinet. Blower. Burner

83% Oil Furnace. Features. Configurations. Cabinet. Blower. Burner 83% Oil Furnace Features Configurations Upflow / Highboy Basement / Lowboy Horizonal / Counterflow Heat Exchanger Heavy-duty 14 gauge steel with a long lasting ceramic fiber combustion chamber Easy access

More information

OIL FURNACES Clean, Comfortable Oil Heat

OIL FURNACES Clean, Comfortable Oil Heat OIL FURNACES Clean, Comfortable Oil Heat Features Foil-faced high density fiberglass insulation to minimize noise and heat loss Heavy duty 14 gauge steel heat exchanger engineered for efficiency; covered

More information

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor 80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor A80-1E Form No. A80-1E-100 (10/2011) Features and Benefits CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped

More information

93% Gas Furnaces Single Stage

93% Gas Furnaces Single Stage Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 93% Gas Furnaces Single Stage Form No. AA931A-100 (05/2012) HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. VL8FA119P60B / VL8RA119P60B (BECKETT AFG) HEATING CAPACITY High Fire * Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 OUTPUT BTUH 1 132,000 119,000 101,000 SEASONAL EFFICIENCY

More information

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG) MODEL NO. THV1C072A948SA (BECKETT AFG) THV1C072A9V4SA (BECKETT AFG) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000

More information

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 95G1E-100 (04/2016) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 95G1-E Features and Benefits CONFIGURATIONS 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Upflow / Horizontal Downflow Form No. R95G1-E-100 (01/2012) HEAT EXCHANGER DESIGN Aluminized

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG)

OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) VHF-ANP / VHF-ANE (BECKETT NX) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTUH

More information

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. VH8FA119P60B VH8FA119T60B (BECKETT AFG) HEATING CAPACITY High Fire * Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 OUTPUT BTUH 1 132,000 119,000 101,000 SEASONAL EFFICIENCY

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTUH

More information

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. OL6*A072D48/DV5 B OL6*A072D48/DV5 R OL6*A072D48/DV5 C HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000

More information

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS A95-1E 95% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow Form No. JA95-1E-100 (10/2011) HEAT EXCHANGER DESIGN Stainless

More information

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS 80% Gas Furnace Single Stage - High Efficiency (Constant Torque) Motor 80G1-E Features and Benefits Form No. R80G1-E-100 (11/2011) CONFIGURATIONS HEAT EXCHANGER DESIGN Aluminized steel tapered crimped

More information

Upflow, Upflow / Horizontal, Counterflow / Horizontal

Upflow, Upflow / Horizontal, Counterflow / Horizontal Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long

More information

93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS

93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS 93% Single Stage Gas Furnace Form No. JA931A-100 (08/2010) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel primary heat exchanger with crimped no

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED BOY FURNACE SPECIFICATIS MODEL NO. HEATING CAPACITY TLF1M087C942SA TLR1M087C942SA High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire High Fire Med-High Fire TLF1M087D9V5SA [6] TLR1M087D9V5SA

More information

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This

More information

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 96G1E-100 (04/2018) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

OIL FIRED LOWBOY FURNACE SPECIFICATIONS OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY VLF-CBP (Front Flue) or VLR-CBP (Rear Flue) High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000

More information

Upflow, Upflow / Horizontal, Counterflow

Upflow, Upflow / Horizontal, Counterflow , / Horizontal, 90/92 Gas Furnace CG90/92 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long life AL29-4C Stainless

More information

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING 92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE FORM NO. 92G1-100 (10/2018) CONFIGURATIONS Upflow/Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized steel design primary heat exchanger with crimped

More information

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES 95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)

More information

OIL FIRED UPFLOW FURNACE SPECIFICATIONS

OIL FIRED UPFLOW FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 156,250 140,000 119,000 156,250 140,000 119,000

More information

OLR Product Specifications

OLR Product Specifications OLR Product Specifications LO BOY OIL FURNACE C Illustrations and photographs are only representative. Some product models may vary. US 85.0 to 86.8 ONLY applies to applications in Canada where the furnace

More information

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains

More information

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA TDD-D-1 Vertical boy, boy Front Flue, boy Rear Flue, Downflow/Horizontal Oil-Fired Furnace XP80 / XV80 boy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA Downflow/Horizontal Front Flue TDF1M087A936,V3,SA

More information

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN A951E PRODUCT SPECIFICATIONS SINGLE STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A951E-100 (10/2018) CONTROLS Single stage gas valve Durable silicon nitride ignitor Self diagnostics saves

More information

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

AF90. AF90 Gas Furnace High Efficiency. Features

AF90.   AF90 Gas Furnace High Efficiency. Features AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty

More information

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

MODEL NO. CLHS1-075T42N CLHS1-100T48N

MODEL NO. CLHS1-075T42N CLHS1-100T48N MODEL NO. CLHS1-075T42N CLHS1-100T48N FUEL GAS NAT/LP 4 GAS NAT/LP 4 INPUT BTUH 75,000 100,000 OUTPUT BTUH 1 73,000 96,000 SEASONAL EFFICIENCY 2 95.0% 95.0% LARGEST REC A/C 3 3.5 T 4 T NOMINAL TEMP RISE

More information

97% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS

97% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS 97% Modulating Variable Speed Gas Furnace Form No. AA97MV-100 (05/2012) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN 409 stainless steel primary heat exchanger

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

96% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS

96% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS 96% Modulating Variable Speed Gas Furnace Form No. AA96MV-100 (08/2010) Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN 409 stainless steel primary heat exchanger

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE / SERIES 93% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE HEATING CAPACITY: 46,000 115,000 BTU/H Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved

More information

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

Available in Upflow/Horizontal and Counterflow/Horizontal models

Available in Upflow/Horizontal and Counterflow/Horizontal models PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow/Horizontal models 80% AFUE 50,000 to 25,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER Aluminized steel

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40,000 140,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Data...8 Wiring Diagram...10 Accessories...11

More information

Rheem Value Series Upflow/Horizontal Gas Furnace

Rheem Value Series Upflow/Horizontal Gas Furnace THIS MODEL Gas Furnaces Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE 80.0% MID HIGH 78% 82% 88%

More information

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h / Heating Input : 40,000 100,000 BTU/h Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev. TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGAA SERIES 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained for year-round comfort. Systems

More information

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency Gas Furnaces PRODUCT SPECIFICATIONS INSTALLATION OPTIONS A vailable in Upflow/Horizontal and Counterflow models 80% AFUE 44,000 to 32,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER A luminized

More information

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH) 1 SEASONAL EFFICIENCY 2 LARGEST REC A/C 3 FUEL

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

F8MTL. Product Specifications

F8MTL. Product Specifications 80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-485 REV. 4 Supersedes Form No. G22-485 Rev. 3 GAS FURNACES UGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h // Heating Input : 40,000 140,000 BTU/h Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 8 Wiring Diagrams...

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No PGMD Series 10 SEER PACKAGE COOLING 1-1/2THRU5TONSINGLEPHASE CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained

More information

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303) TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN 40-130 MBH INPUT HIGH-EFFICIENCY INDUCED COMBUSTION DESCRIPTION These high efficiency, dedicated downflow compact units employ induced

More information

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Product Data. that this product meets the S 95% AFUE S Two -stage operation DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21047-001 Rev. A (4/00) DESCRIPTION These high efficiency, compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils MGE4 Gas Heating / Electric Cooling Packaged Thru-the-Wall Units Form No.: MGE4-100 (07/2010) FEATURES Up to 10.6 EER cooling efficiency Completely self-contained heating and cooling package No outside

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) TECHNICAL SPECIFICATIONS HMG*T Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG*T series of air handlers, when combined with our heat pump or air conditioner, offer

More information

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE FORM NO. G22-448 REV. 10 Supersedes Form No. G22-448 Rev. 9 GAS FURNACES UGPH- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS

A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE FORM NO. A97MV-100 (06/2014) CONTROLS Communicating control enabled Modulating gas valve Thermostat flexibility: works with the Comfort

More information

G8MVL. Product Specifications

G8MVL. Product Specifications 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in

More information

MGE4 FEATURES REFRIGERANT SYSTEM HEAT EXCHANGER CABINET BLOWER

MGE4 FEATURES REFRIGERANT SYSTEM HEAT EXCHANGER CABINET BLOWER GAS HEATING / ELECTRIC COOLING PACKAGED UNITS FORM NO. -100 (07/2017) FEATURES Up to 10.0 EER cooling efficiency Less than 2% cabinet air leakage Completely self-contained heating and cooling package No

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger. 036-21053-001 Rev. A (4/00) DESCRIPTION These high efficiency, dedicated downflow compact units employ induced combustion, reliable hot surface ignition and high heat transfer tubular heat exchangers.

More information

A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN

A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE FORM NO. A802V-100 (04/2016) VENTING Rotatable draft inducer for venting flexibility INSTALLATION FEATURES Left and right utility connections

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

UPFLOW/ HORIZONTAL GAS FURNACE

UPFLOW/ HORIZONTAL GAS FURNACE FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE

More information

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information