Bussmann series IEC cylindrical fuses
|
|
- Eugenia Allen
- 6 years ago
- Views:
Transcription
1 IE and ritish Standard fuses 5 ontents ussmann series IE cylindrical fuses Section page escription Fuses S Type P and fuses (N, S and PON) HR Form II lass fuses (GL) 3 HRI industrial ceramic body fuses HRI- (IF) 4 HRI- (IF06) HRI-J fast-acting (J) HRI-Misc. Type K (IH, IK and IL) HR Form II current-limiting fuses (H07, K07, L4, M4, L09, M09, P09, P, R) 5 6 S88 Part fuses SS, NS, ES ST, NIT, O, O, OS, EO, EO 7 S88 EF, FF, FG, GF, GG, GH IN Type iazed (6, 7, 33, 5) IN Type N Neozed (NZ0, NZ0) 8 9 NH HR fuses (NHG) 0- JKS-700 fast-acting, current limiting UL Recognized and S omponent cceptance 700 Vac fuses up to 60 amps NH fuse blocks and accessories (S, T) Fuses continued IE 6069 industrial fuses with and without indicator/striker omplete portfolio of 8- mm diameter lass am and lass gg cylindrical fuses for industrial applications lass gg ferrule (0G, 4G, G) 3 lass am ferrule (0M, 4M, M) 4 HR fuse holders Master SFEloc 5 Red Spot USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries 5- IE and ritish Standard fuses,,,,,, E, EFS
2 5 IE and ritish Standard fuses N, S and PON S Type P and fuses S time-delay Type and P fuses. imensions in (mm) 50 Vac (N and PON) 600 Vac (S) Up to 60 mps F IR 0 k minimum 70 to 600 E S ertified to. No. 59., E Features Economical fuse in a variety of ratings for applications not requiring time-delay Typical applications Lighting, heating and other circuits not subject to temporary surges and where available short-circuit current are relatively low atalog no.* atalog symbol vailable amp ratings Time-elay S Type "" fuses N** S 50 Vac 600 Vac One-time S Type "P" fuses 0,, 5, 0, 5, 30, 35, 40, 45, 50, 60, 70,, 90, 00, 0, 5, 50, 75, 00, 5, 50, 300, 350, 400, 450, 500, 600 0,, 5, 0, 5, 30, 35, 40, 45, 50, 60, 70,, 90, 00, 0, 5, 50,75, 00, 5, 50, 300, 350, 400, 450, 500, 600 PON 50 Vac 5, 0, 5, 30, 35, 40, 45, 50, 60 * To order, specify catalog symbol and amp rating, e.g., N30, S0 or PON40. ** elow 0 amps, use FRN-R. elow 0 amps, use FRS-R. mps E F N/PON 50 Vac Up to 30.0 (5) 0.6 (4) (76) 0.8 () (49).0 (5) 0. (3) 0.8 (9) (85).4 (35) 4. (05) 0. (5). (9) (9).9 (48) 4.6 (8) 0.3 (6).6 (4) (64).3 (57) 5. (3) 0.3 (6) (5) S 600 Vac Up to (7) 0.8 () (40). (7) (00).0 (5) 0. (3) 0.8 (9) (45).4 (35) 6. (6) 0. (5). (9) (95).9 (48) 7. (8) 0.3 (6).6 (4) (340).3 (57) 8. (08) 0.3 (6) (5) Recommended fuse blocks atalog no.* Fuse amps Up to 30 HM5030-(poles) HM60030-(poles) HM5060-(poles) HM60060-(poles) HM500-(poles) HM6000-(poles) 0-00 HM500-(poles) HM6000-(poles) HM5400-(poles) HM60400-(poles) HM5600-(poles) HM60600-(poles) * To order, specify, or 3 poles, e.g., HM5030-_. See data sheets 089 (30-60 ) and 39 ( ) for available terminals. ata sheet no USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries
3 IE and ritish Standard fuses 5 GL HR Form II lass fuses urrent-limiting HRII- fuses designed to withstand inrush currents on typical motor start-ups while offering high current limitation in the short-circuit region. See drawings for dimensions. 600 Vac 50 Vdc (-30 ) mps -600 IR 00 k 40 k S ertified,. No. 06, lass 4,File 53787, E atalog no. (amps) GL- GL-5 GL- GL-5 GL- GL-30 GL-90 GL-50 GL-3 GL-35 GL-00 GL-300 GL-4 GL-40 GL-0 GL-350 GL-6 GL-45 GL-5 GL-400 GL-0 GL-50 GL-50 GL-450 GL-5 GL-60 GL-75 GL-500 GL-0 GL-70 GL-00 GL-600 Features imensions in (mm) GL (5.56) GL (50.8). (7.04) 3.3 (84.4) 0. (5.56).0 (50.8). (7.04) 3.5 (88.9) (8.7) GL (5.56) 0. (5.56).39 (60.7) 3.64 (9.47) 4.3 (09.54) (8.7) GL (9.53) 3.00 (76.) 4.30 (09.) 5.3 (34.87) 0.34 (8.73) (8.7) 0.8 (0.64) 0.50 (.7) 0.8 (0.64) 0.75 (9.05) (8.7).34 (34.04) 0.06 (.59) 0.94 (3.8) 0.75 (9.05) 0.06 (.59).06 (6.9) 0.09 (.9).375 (34.93).50 (38.).0 (5.4) 0.5 (3.8) 0.9 (4.76) IE and ritish Standard fuses lose sizing to loads allows using smaller and less costly switches Provides a higher degree of short-circuit protection Helps protect motors against burnout from overloads Typical applications GL (76.) 5.5 (33.35) 8.9 (07.96).0 (5.4).38 (60.33) For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads vailable Red Spot fuse holders 0.4 (0.3).0 (5.4) Fuse amps Up to 3 atalog symbol* RS3_ RS63_ RS00_ 0-00 RS00_ GL (5.4) 3.0 (76.) 5.5 (33.35) 8.9 (07.96) 0.60 (5.4) (9.53) 3.00 (76.) RS400_ * See Red Spot data sheet no for terminal options. USSMNN SERIES FULL LINE TLOG 007 JUNE 07 ata sheet no. 45 Eaton.com/bussmannseries 5-3
4 5 IE and ritish Standard fuses IF HRI- industrial ceramic body fuses The HRI- bolt-on, ceramic body fuse provides both overload and short-circuit protection to HRI requirements. Offset blades for bolt-on mounting IF fuse fits the ussmann series Red Spot fuse holder (data sheet 0083) and Master fuse holder (data sheet number 43). 600 Vac 50 Vdc mps -30 IR 00 k RMS Sym. S., No. 06-M9, E atalog no. mps atalog no. mps IF 5IF 5 3IF 3 0IF 0 6IF 6 5IF 5 0IF 0 30IF 30 Features lose sizing to loads allows using smaller and less costly switches Provides a higher degree of short-circuit protection Helps protect motors against burnout from overloads Typical applications For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads Recommended fuse holders mps escription atalog no.* Up to 0 Red Spot RS0_(terminal option) Up to 30 Master M0F IF06 HRI- industrial ceramic body fuses miniature offset clip-in blade, ceramic body industrial fuse that provides both short-circuit and overload protection and the IF06 fits the 30 SFEloc fuse holder (data sheet number 433). 600 Vac 50 Vdc mps -30 IR 00 k RMS Sym. S. No. 06-M9 (3-30 only), E atalog no. mps atalog no. mps IF06 5IF06 5 3IF06 3 0IF06 0 6IF06 6 5IF06 5 0IF IF06 30 Features lose sizing to loads allows using smaller and less costly switches Provides a higher degree of short-circuit protection Helps protect motors against burnout from overloads Typical applications For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads Recommended fuse holders mps escription atalog no.* Up to 30 SFEloc 30(terminal option) * See data sheet no. 433 for SFEloc details. imensions in (mm) * See data sheet no (Red Spot) and 43 (Master) for details. imensions in (mm).38 (60).44 (36).5 (55).44 (36) 0.54 (4) 0.5 (3) 0.54 (4) 0.9 (5) 0.44 () 0.4 (4) 0.03 (4).75 (45) 0.03 () ata sheet no. 47 ata sheet no USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries
5 IE and ritish Standard fuses 5 J HRI-J fast-acting fuses IH, IK and IL HRI Misc. Type K fuses HRI-J bolt-on, ceramic body fast-acting fuses are industrial duty fuses with the excellent current-limiting characteristics of fast-acting HRI-J fuses to limit damage to equipment and installations from the thermal and magnetic energy associated with a large short-circuit current. Overload characteristics limit cable damage due to low overload currents. 600 Vac (or less) 50 Vdc mps -600 IR 00 k S. No. 06-M9; designed to S88:, IE atalog no. (amps)j J 35J 00J 300J 3J 40J 0J 350J 6J 45J 5J 400J 0J 50J 50J 450J 5J 60J 75J 500J 0J 70J 00J 600J 5J J 5J 30J 90J 50J imensions in (mm) E J K F H Misc. Type K HRI bolt-on, ceramic body fuses provide both overload and short-circuit protection, featuring offset blades for bolt down mounting. 600 V mps -00 IR 00 k@600 V S. No. 06-M9, E atalog no. (amp)ih, IK, IL IH07 5IH07 35IK07 IL4 3IH07 0IH07 40IK07 90IL4 6IH07 5IH07 50IK07 00IL4 0IH07 30IH07 60IK07 imensions in (mm) The IL4 has a rejection hole, not a slot as shown above. mps E F G H J K L Up to K.5 (57).8 (58).75 (70) 0.94 (4).06 (7).44 (37) 3.38 (86) 3.56 (9) 4.38 () F L 0.38 (0) 0.5 (3) 0.75 (9) 0.04 () 0.05 () 0.09 (3) H.88 (73).88 (73) 3.69 (94) G G 0. (5) 0. (5) 0.34 (9) J E 0.3 (8) 0.4 () 0.4 () (5).09 (8).5 (39) 0.0 (3) 0.3 (3).38 (60).38 (6).9 (74) IE and ritish Standard fuses Up to 60 mps E F G H J K Up to 30.5 (57) (60) (7) 5.75 (46) 7.3 (8) 8 (03) 0.5 (3) 0.63 (6) 3.63 (9) 4.38 () 5.5 (33) 6 (5) 0.8 ().06 (7).3 (8).63 (4).3 (54).63 (66) 0.75 (9).3 (9).63 (4) (5) 70 to (3) 0.9 (5) 0.5 (6) 0.38 (0) (5).38 (35).88 (48).3 (54) 0.5 (3) 0.69 (8) 0.94 (4) (5) 0.8 (7) 0.8 (7) 0.4 (0) 0.53 (4) 0.38 (0) 0.38 (0) 0.53 (4) 0.69 (8) G.63 (67) 3 (76) 3.38 (86) 3.75 (96) Recommended fuse holders mps Red Spot* Master* Up to 30 RS3_ M30F RS63_ M60F -00 RS00_ * See data sheet no (Red Spot) and 43 (Master) for details. ata sheet no. 49 USSMNN SERIES FULL LINE TLOG 007 JUNE 07 ata sheet no. 430 Eaton.com/bussmannseries 5-5
6 5 IE and ritish Standard fuses HR Form II current-limiting fuses HR Form II bolt-on, ceramic body current-limiting fuses. 600 Vac (or less) 50 Vdc imensions in (mm) G G F H H07 offset blades F E E J J mps -600 IR 00 k RMS Sym. H K07, K07R, L4, M4 offset blades S. No. 06-M9, S88:, IE 6069:, E G H (amps) catalog no. H07 offset blades H07 6H07 5H07 5H07 4H07 0H07 0H07 30H07 K07 offset blades 40K07 60K07 00K07R 50K07 L4 offset blades L4 M4 offset blades K07R 00L4 5M4* 50M4* 00M4* L09 center blades L09* M09 center blades 00L09* 5M09 50M09 00M09 P09 center blades 50P09* 300P09* 350P09* 400P09* P center blades 50P 300P 350P 400P R center blades 450R 500R 600R * Not suitable for installation in Red Spot fuse holders. Typical applications Used to protect motor control circuits, together with contactors and overload protection relays to provide Type coordination per IE Recommended fuse holders: Red Spot up to 400 amps (data sheet no.0083) and Master up to 00 amps (data sheet no. 43). G L09, M09, P09 center blades K F F P, R center blades atalog symbol/ style E F G H J K H K E E S category H07 offset blades HRII- (35) (4) (85) (9) () (73) (6) (8) (4) K07 offset blades HRII- (56) () (87) (3) () (73) (6) (8) () HRII- (56) () (95) (3) () (73) (6) (8) () MIS L4 offset blades HRII- (60) () () (4) (3) (94) (9) () (5) M4 offset blades HRII- (65) (38) () (9) () (94) (9) () MIS L09 center blades HRII- (60) () (7) (4) (3) () (9) () MIS M09 center blades HRII- (65) (38) (36) (9) (3) () (9) (4) P09 center blades HRII- (78) (59) (36) (5) (5) () (9) (3) MIS P center blades HRII- (78) (59) (0) (5) (5) (33) (0) (6) (5) R center blades HRII- (8) (73) (0) (5) (6) (33) (0) (6) (5) ata sheet no USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries
7 IE and ritish Standard fuses 5 SS, NS, ES S88 Part fuses The NS and ES are low voltage offset blade, ceramic body fuses complying with general purpose gg characteristics Vac mps -63 0M5 to 63M00 motor starter ratings IR 33 k (SS) k (NS, ES) Meets the requirements of S88 Part and IE 6069-, E atalog no.* atalog symbol mps (class) Max Vac SS, 4, 6, 0, 6, 0, 5, 3 (gg) 40 E NS 0M5, 0M3, 0M36, 3M36, 3M40, 3M50, 3M63 (gm) 45, 4, 6, 0, 6, 0, 5, 3 (gg) 550 ES 40, 50, 63 (gg) 63M, 63M00 (gm) 45, 4, 6, 0, 6, 0, 5, 3 (gg) 550 * To order, specify catalog symbol and amp rating, e.g., SS0. "M" indicates motor starter ratings. Recommended fuse holders Fuse symbol NS ES atalog no. 3NNSF 63ENSF S88 ref. F F ST, NIT, O, O, OS, EO, EO S88 Part fuses The ST to EO type ceramic body, offset bolt-on blade low voltage fuses complying with general purpose gg characteristics Vac mps -00 0M5 to 00M35 motor starter ratings IR 33 k (ST) k (NIT, O, O, EO, EO, OS) Meets the requirements of S88 Part and IE 6069-, E atalog no.* atalog symbol mps (class) Max Vac ST, 4, 6, 0, 6, 0, 5, 3 (gg) 40 NIT, 4, 6, 0, 6, 0, 5, 3 (gg) 0M5, 0M3 (gm) 550 3M40, 3M50, 3M63 (gm) 45 O, 4, 6, 0, 6, 0, 5, 3, (gg) 550 3M40, 3M50, 3M63 (gm) 500 O 40, 50, 63 (gg) 63M, 63M00 (gm) 3, 40, 50, 63,, 00 (gg) 550 EO 00M5, 00M60, 00M00 (gm) 45 EO 5, 60, 00 (gg) 00M35 (gm) OS, 00 (gg) M5, 00M60 (gm) 45 * To order, specify basic catalog symbol and amp rating. E.g., O6. "M" indicates motor starter ratings. S88 ref IE and ritish Standard fuses Typical applications The ST type are used in 40 V street lighting cut-outs NIT to EO types used for industrial and general purpose applications Recommended fuse blocks and holders Fuse catalog symbol NIT O O OS EO lock/holder catalog no.* M3F, RS0_ M3F, RS3_ M63F, RS63_ M00F, RS00_ H-0 * See data sheet no. 43 (M_), 0083 (RS_) and 00 (H-_). ata sheet no. 405 (SS), 400 (NS) and 40 (ES) USSMNN SERIES FULL LINE TLOG 007 JUNE 07 ata sheet no. 43 (ST), 406 (NIT), 409 (O), 4 (O), 407 (OS), 45 (EO) and 47 (EO) Eaton.com/bussmannseries 5-7
8 5 IE and ritish Standard fuses,,,,,, E, EFS S88 fuses eramic body, center blade two-hole bolt-on low voltage fuses that comply with general purpose gg characteristics and available up to 400 amps with two hole mount and up to 50 amps with four hole mount. 45/550 Vac 50 Vdc mps M to 400M500 motor starter ratings IR see catalog numbers table Meets the requirements of S88 Parts and and IE 6069-, E atalog no.* IR ( k) Max volts atalog symbol mps (class) S88 ref., 4, 6, 0, 6, 0 (gg) , 3 (gg) 500, 4, 6, 0, 6, 0 (gg) , 3 (gg) , 50, 63 (gg) 63M, 63M00 (gm) , 50, 63 (gg) E EFS, 00 (gg) 00M5, 00M60, 00M00 (gm) 5, 60, 00 (gg) 00M50, 00M35 (gm) 50, 35, 355, 400 (gg) M400 (gm) M500 (gm) 550 5, 60, 00, 50, 35 (gg) 45 * To order, specify catalog symbol and amp rating. E.g., 40. "M" indicates motor starter ratings. EF, FF, FG, GF, GG, GH S88 fuses eramic body, center blade four-hole bolt-on low voltage fuses complying with general purpose gg characteristics and available up to 400 amps with two hole mount and up to 50 amps with four hole mount. (see catalog numbers table) 45/690 Vac 50/400 Vdc mps IR see catalog numbers table Meets the requirements of S88 Parts and and IE 6069-, E atalog no.* IR ( k) Max volts atalog symbol mps (class) EF 355, 400 (gg) M500 (gm) 550 S88 ref. FF 450, 500, 560, 630 (gg) FG 450, 500, 560, 630 (gg) GF 70, 0 (gg) GG 70, 0 (gg) , 50 (gg) GH 70, 0, 000, * To order, specify catalog symbol and amp rating, e.g., FG450. "M" indicates motor starter ratings. Recommended fuse blocks Fuse catalog symbol Modular block catalog no.* H-0 H- H-0 H- H- H- E H-3 * See data sheet no. 00 (H-0_) and 0 (H-_) for details. ata sheets no. 40 (), 4 (), 43 (), 44 (), 46 (), 48 (), 49 (E) and 4 (EFS) ata sheet no. 40 (EF), 40 (FF), 4 (FG), 403 (GF), 404 (GG) and 408 (GH) 5-8 USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries
9 IE and ritish Standard fuses 5 6, 7, 33, 5 IN Type iazed fuses IN style Type ceramic body low voltage fuses. 500 Vac mps -00 IR 50 k IE 6069 and IN 4955, E NZ0, NZ0 IN Type N Neozed fuses IN style Type N ceramic body low voltage. 400 Vac mps -63 IR 50 k IE 6069 and IN 4955, E atalog no. mps "" dimension olor code Fig. 6 6 Pink rown Green Red Grey 06 0 lue Yellow 7 6 Pink rown Green Red Grey 07 0 lue Yellow lack White opper 5 5 Silver Red dditional 500 V quick acting fuses in body sizes 6, 7, 33 and 5 rated -00. Reference number suffixed "Q." E.g., 07Q. Gauge rings and keys can also be supplied. 3 4 atalog no. mps "" dimension olor code NZ0 Pink 4NZ0 4 rown 6NZ0 6 Green 0NZ0 0 Red 6NZ0 6 Grey 0NZ0 0 5 lue 5NZ0 5 5 Yellow 35NZ lack 50NZ White 63NZ opper imensions mm 36 IE and ritish Standard fuses imensions mm Fig. Fig. Fig. 3 Fig. 4 ata sheet no. 44 ata sheet no. 44 USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries 5-9
10 5 IE and ritish Standard fuses NHG NH HR fuses NHG NH HR fuses IN 000 to 4 lass: gg/gl IN square bodied, dual indication industrial fuses with voltage conducting metal gripping lugs. They are made of a steatite insulator, corrosion-proof (aluminum) metal parts with full-contact and silver-plated copper blades. ll NHG fuses feature a selectivity ratio: :.6 up to 500 Vac. 500 Vac 690 Vac mps -50 IR 0 k Frequency 45-6 Hz operating IE 6069, VE 0636, IN 4360 E (500 Vac only) imensions mm Fuse size a a a 3 a 4 b c c e e e 3 e 4 f Recommended fuse blocks lock catalog no. a 4 a 3 a a Fuse size S S- *, S- 0,, 03, 3 ata sheet no. 064 (500 V), 7009 (690 V) d b f c c e 3 e e 4 min. e 500 Vac gg/gl dual indicator voltage conducting metal gripping lugs mps atalog no. 000 size NHG NHG NHG NHG NHG NHG NHG NHG NHG NHG NHG NHG000 NHG NHG size 50 50NHG NHG00 NHG NHG00 5 5NHG NHG00 0 size 6 6NHG0 0 0NHG0 6 6NHG0 0 0NHG0 5 5NHG0 3 3NHG NHG NHG NHG NHG0 NHG NHG0 5 5NHG NHG0 0 size 6 6NHG0 0 0NHG0 6 6NHG0 0 0NHG0 5 5NHG0 3 3NHG NHG NHG NHG NHG0 NHG NHG0 5 5NHG NHG0 mps atalog no. size 50 50NHG 63 63NHG NHG 00 00NHG 5 5NHG 60 60NHG 00 00NHG 4 4NHG 50 50NHG 35 35NHG NHG 0 size 35 35NHG NHG NHG NHG0 NHG NHG0 5 5NHG NHG NHG0 4 4NHG NHG0 size 50 50NHG NHG 35 35NHG NHG NHG 45 45NHG NHG NHG 03 size 50 50NHG NHG NHG NHG03 3 size 35 35NHG NHG NHG NHG NHG NHG NHG3 0 0NHG3 4 size* NHG4G NHG4G 0 0NHG4G NHG4G 50 50NHG4G * Size 4 is a a single indicator fuse with slotted end blades. 5-0 USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries
11 IE and ritish Standard fuses 5 NHG NH HR fuses JKS-700 fast-acting fuses 690 Vac gg/gl dual indicator voltage conducting metal gripping lugs mps 000 size atalog no. NHG NHG NHG NHG NHG NHG NHG NHG NHG NHG NHG NHG size 50 50NHG NHG NHG NHG NHG * 60NHG size 50 50NHG NHG-690 NHG NHG NHG NHG NHG NHG NHG-690 mps size atalog no NHG NHG NHG NHG size 50 50NHG NHG NHG NHG NHG NHG size** NHG NHG4-690 * 60 amps rated at 660 Vac. ** Size 4 is a single indicator fuse with slotted end blades. The JKS-700 is a fast-acting, current-limiting fuse that is UL Recognized and has S omponent cceptance for applications up to 700 Vac. The JKS-700 is available in ratings up to 60 amps with the same dimensions as a standard lass J fuses; but its voltage rating places it outside the standard lass J fuse class. ussmann recommends the JM7000 modular fuse block and the JM7000-MW power distribution fuse block for the 30 amp case size JKS-700 fuses. See page 8-8 for details. 700 Vac (or less) mps 5-60 IR Minimum 6I n 00 k RMS Sym. Operating class ar UL Recognized, 48-3 Semiconductor Fuses, File E564 S omponent cceptance,. No 48.3 Semiconductor Fuses, lass 4-30 Features urrent limitation for non-inductive circuits provides currentlimiting response to maximum ground fault and short-circuit conditions 00 k interrupting rating provides protection at all circuit locations Economical circuit protection for high-fault current circuits Typical applications Power panelboards up to 700 Vac IE and ritish Standard fuses Machinery disconnects up to 700 Vac atalog no. (amps) JKS JKS JKS JKS ata sheet no. 064 (500 V), 7009 (690 V) USSMNN SERIES FULL LINE TLOG 007 JUNE 07 ata sheet no. 06 Eaton.com/bussmannseries 5-
12 5 IE and ritish Standard fuses S_ and T_ NH fuse blocks Shroud kits NH fuse bases feature thermoplastic bodies, and IN-Rail and screw mounting (size 4 is screw fix). They are available with a range of protection accessories for live parts for IP0 protection. up to 690 Vac mps up to 50 NH fuse sizes 000 to 4 IE 6069, IN 4360 Typical applications Protection of industrial circuits and electrical apparatus atalog no. Fuse size Poles mps atalog no. IN-Rail or screw mount 00 3 S T00- S T- S T- S T3- Screw mount only arton qty S4-S 3 4 Neutrals NH size mps atalog no. arton qty. 50 SL SL SL-3 3 Fuse extraction handle Size atalog no. arton qty FEH ccepts fuse sizes 000 and 00 0 and 0 and 03 and 3 atalog no. Fits fuse block T00-IP0 T00- T-IP0 T- T-IP0 T- T3-IP0 T3- S-SK S and S S3-SK S3 Terminal covers and separators (from shroud kits) Terminal covers () Separator (3) NH size mps at. no. arton qty. at. no. arton qty. 00* 60 S00* 6 00* 0 60 S S S S3 6 3 * For single pole only Phase barrier kits* atalog no. Fits fuse block S-P S and S S3-P S3 * Kits include phase barriers and ganging links. ata sheet USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries
13 IE and ritish Standard fuses 5 lass gg IE 6069 industrial ferrule fuses 0 to mm diameter IE lass gg fuses with optional indicators (0x38mm only) and strikers. See catalog numbers for availability and ratings. 0x38mm, lass gg, 500 and 400 Vac, 0.5 to 3 atalog no. Standard W/ indicator Vac mps IR (k) Holder/block 0G G 0G 0G4 4 0G6 6 0G G0 0 0G HM IN-Rail*, 0 0G6 6 MM block 0G0 0 0G5 5 0G G G G40I G50I * Not recommended for use with indicator version..x58mm, lass gg, 400, 500 and 690 Vac, to 5 atalog no. Standard W/ striker Vac mps IR (k) Holder/block G G4 G4S 4 G6 G6S 6 G8 G8S 8 G0 G0S 0 G GS G6 G6S G0 G0S 0 G5 G5S 5 G3 G3S 3 G40 G40S 40 G50 G50S 50 G63 G63S 63 G GS 500 G00 G00S 00 G5 G5S Ø H IN-Rail*, JM7000 block 0 * Use striker version to actuate optional, external microswitch. imensions mm atalog symbol Ø ØE Indicator/striker 0G G G Ø E IE and ritish Standard fuses 4x5mm, lass gg, 400, 500 and 690 Vac, to 50 atalog no. Standard W/ striker Vac mps IR ( k) Holder 4G 690 4G 4GS G G4S G G6S G G8S G G0S G 690 4GS H4 IN-Rail** 4G G6S G G0S G G5S 4G3 4G3S G40 4G40S G50 4G50S ** Not recommended for use with indicator version, use striker version to actuate optional, external microswitch USSMNN SERIES FULL LINE TLOG 007 JUNE 07 ata sheet no. 705 Eaton.com/bussmannseries 5-3
14 5 IE and ritish Standard fuses lass am IE 6069 industrial ferrule fuses 0 to mm diameter IE lass am fuses with optional indicators (x58mm only) and strikers. See catalog numbers for availability and ratings. 0x38mm, lass am, 500 and 400 Vac, 0.5 to 5 atalog no. Standard Vac mps IR (k) Holder/block 0M M 0M 0M4 4 0M HM in-rail, 0M8 8 MM block 0M0 0 0M 0M6 6 0M M5 5 4x5mm, lass am, 400, 500 and 690 Vac, 0.5 to 50 atalog no. Standard W/ striker Vac mps IR (k) Holder 4M M M 4M 4MS M M4S M M6S M M8S M M0S H4 IN-Rail** 4M 690 4MS M M6S M M0S M M5S 4M3 4M3S M40 4M40S M50 4M50S ** Use striker version to actuate optional, external microswitch. x58mm, lass am, 400, 500 and 690 Vac, to 5 atalog no. W/ Standard indicator W/ striker Vac mps IR (k) Holder/block M M4 4 M6 6 M8 8 M0 0 M MS M6 M6S M0 M0S 0 H IN-Rail*, M5 M5S 5 JM7000 block M3 M3S 3 M40 M40S 40 M50 M50S 50 M63 M63S 63 M MS 500 M00 M00S 00 0 M5 M5I M5S * Not recommended for use with indicator version, use striker version to actuate optional, external microswitch. imensions mm Ø atalog symbol Ø ØE Indicator/striker 0M M M Ø E ata sheet no USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries
15 IE and ritish Standard fuses 5 HR fuse holders Master The ussmann series Master HR fuse holder features a unique cam-action for easy fuse removal while allowing significantly improved contact pressure between fuse carrier and base contact that enhances electrical performance. range of lockable safety carriers for the fuse holder (catalog reference LS), are available. 690 V mps up to 00 S. No. 39; IE 69 and S88, E SFEloc The ussmann series SFEloc HR fuse holders (for use with HRI- fuses) provides a positive, stress-free fuse fitting and locks it in position to ensure safe insertion and withdrawal from the base. ase contacts are fully shrouded to help protect against electric shock. Shrouds utilize simple slide/snap action allowing access to the contact terminal screws. It can be mounted on a 35mm IN-Rail or panel-mounted with a single screw. 600 V mps atalog no. mps etails for Fuses accepted M0F 30 HRI- applications _IF M30F 30 _H07 M60F 60 _K07 HRII applications M00F 00 _K07R ccessories atalog no. mps escription Master accepted 0S 30 M0F 3S 30 ack stud M30F 60/00S 60/00 M60/00F GLP ll Ganging link kit 3-Pole 0LS 30 M0F 3LS 30 Security carrier with clip M30F 63/00LS 60/00 M60/00F esigned to accommodate the compact range of offset blade fuse to S. No. 06, HRI-, E atalog no.* mps onnection Fuses accepted 30F 30S 30FS 60F 60S 60FS * For use with HRI- fuses. Front ack Front-back Front ack Front-back ussmann series Red Spot fuse holders _IF06 EK-(amp) IE and ritish Standard fuses These versatile S ertified and IP0 finger-safe fuse holders for S88 HR industrial fuses are available in ratings from 0 to 400 amps. Padlock inserts, warning carriers and fuse adapter accessories enhance safety and application flexibility. See data sheet no for details. USSMNN SERIES FULL LINE TLOG 007 JUNE 07 Eaton.com/bussmannseries 5-5
16 USSMNN SERIES Enhanced safety. Improved system reliability. Simplified inventory. It s easier than ever to improve your circuit protection while efficiently reducing your fuse inventory. Leveraging ussmann series ultimate protection fuses, our Low-Peak Upgrade program couples the industry s most advanced circuit protection with our extensive knowledge to deliver enganced safety, improved system reliability and simplified inventory. In just three simple steps, you ll save time and increase productivity. ll by using ussmann series Low-Peak fuses. Three steps to ultimate protection: udit nalyze 3 Implement Visit Eaton.com/bussmannseries to learn more. Follow us on social media to get the latest product and support information.
Bussmann series IEC cylindrical fuses
IEC and ritish Standard fuses 5 Contents ussmann series IEC cylindrical fuses Complete portfolio of 8-22 mm diameter Class am and Class gg cylindrical fuses for industrial applications escription Fuses
More informationIEC and British Standard Fuses.
IEC and British Standard Fuses Section Contents Page Application Data..................... 45-46 CSA Type P and Type D fuses (CDS, CDN & PON)............................47 Tron HRC Form II Class C fuses
More informationNH HRC Fuses. IEC & British Standard Fuses NHG B
NH HRC Fuses NHG B Specifications Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact,
More informationR-Rated medium voltage fuses for motor circuit protection
Technical ata 6001 Supersedes September 2017 Features and benefits escription: Indoor/enclosure, R-Rated medium voltage, current-limiting fuses for motor circuit protection. urrent-limiting R-Rated fuses
More informationR-Rated medium voltage fuses for motor circuit protection
Technical ata 6001 Supersedes ecember 2015 Features and benefits escription: Indoor/enclosure, R-Rated medium voltage, current-limiting fuses for motor circuit protection. urrent-limiting R-Rated fuses
More informationLow Voltage Fuses AFaC and BaC types
Fa and a types Fa and a type currentlimiting fuses 600V /, 3 400 mps escription The Fa and a type have an excellent current-limiting performance with an interrupting capacity as high as 100k at 600V /.
More informationPractical and completely safe
FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Learn more at Eaton.com/Cooper Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution
More informationFRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FRNR400 400A 250V TD Class RK5 Dual Elem Fuse-Fusetron Catalog Number Manufacturer Description Weight per unit Product
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution for all applications. Only Eaton
More informationQO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers
QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for
More informationnew NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price
NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high
More informationLow-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses
Technical Data 6 Supersedes August 2015 Low-Peak LPJ Class J 600Vac/Vdc, 1-60A, Catalog symbol: LPJ-(amp)SP (non-indicating) LPJ-(amp)SPI (indicating) Description: Bussmann series Ultimate protection LPJ
More informationBussmann series NH catalogue. Leadership in circuit protection
Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places
More informationN0N A 250V One-Time Class H Fuse
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 AllenWatson@elliottelectric.com N0N 250V One-Time Class H Fuse Catalog Number Manufacturer Description Weight per unit
More informationBUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352
8.3kV E-Rated Description: E-Rated, current-limiting, medium voltage fuses for feeder circuit, switchgear and transformer protection. Supersedes pril 2015 USSMNN SERIES Medium voltage fuses for feeder
More informationQO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories
QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.
More informationLPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse
LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)
More informationComplete and reliable solar circuit protection
Contents Photovoltaic fuses, holders, and blocks 6 Complete and reliable solar circuit protection Description Fuses Fuse size Volts Amps PVM 13/32" x 1-1/2" 600 4-30 PVS-R RK5 600 20-400 Section page PV-_A10_
More informationLow Voltage Catalogue. Domestic Applications to BS1361 & BS1312. Consumer Unit Fuse Link 240V / 5-45 A. Plug Top Fuse Links 240V / 1-13A
Domestic Applications to BS1361 & BS1312 Consumer Fuse Link 240V / 5-45 A Description: Cylindrical Fuse Links for domestic application according to BS1361 Volts: - 240V Amps: - 5-45A IR - 16.5kA Applications:
More informationLow-Peak fuses offer the industry s most advanced circuit protection
Low voltage, branch circuit fuses ussmann series Low-Peak fuses offer the industry s most advanced circuit protection Section page Description Fuse holder and block selection guide 2 Fuse reducers ranch
More informationHigh Speed Fuses. Section Contents Page
Section Contents Page General pplications.......................1-13 North merican fuses & accessories...........1-11 DFJ - High speed Class J fuse.................. 15 Square ody fuses & accessories............
More informationFusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses
Technical Data1019 Supersedes July 2013 Fusetron FRN-R Class RK5 250Vac/125Vdc Catalog symbols: FRN-R-_ (non-indicating) FRN-R-_ID (indicating) Description: Eaton Bussmann series advanced protection, energy
More informationLPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse
LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)
More informationGears & Fuse Gears. IEC General Purpose Fuses NH Fuses Plastic Bases 00-EP/TP. 690V Polyester fuse bases for NH fuse-links.
-EP/TP NH fuse bases are designed for fuse-links with rated voltages up to 69 V and VD. They are in compliance with IE 669, DIN VDE 66, part, and DIN 6 (dimensions). NH fuse bases are available for delivery
More informationINDUSTRIAL CYLINDRICAL FUSE LINKS
gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal
More informationUp to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks
Technical Data 09 Effective June 06 Up to 60 A Class R 50 V and 600 V ferrule power distribution fuse blocks Catalog symbols: RM5060-_MW_ RM60030-_MW_ RM60060-_MW_ Features and benefits: Combination power
More informationBussmann. Circuit Protection Solutions
ussmann Circuit Protection Solutions ussmann Worldwide Circuit Protection Solutions World s leading supplier of fuses and fusible protection systems, ussmann continues its 88-year history of blazing new
More informationLow voltage, branch circuit fuses
Low voltage, branch circuit fuses Contents Description Page Fuse holder and block selection guide -2 Class fuse dimensions -5 Fuses by fuse class Class Fuses Volts CC....... LP-CC............... 600V.....
More informationFor Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses
mp-trap 2000 Fuses For Type 2, No Damage circuit protection in all the configurations you need. Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive
More informationLPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 LPCC3 3A 600V TD Class CC Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPCC3
More informationIEC Low Voltage Products Module 4
IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!
More informationfuses fuse holders CYLINDRICAL
fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES
More informationBussmann series NH bases
Supersedes October 2013 BUSSMANN Product description Eaton s range has been designed with thermoplastic bodies DIN-Rail and/or screw mounting (size 4 screw mounting only). This range comes with a accessories
More informationAmp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...
Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. A Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive
More informationClass J modular ferrule and knifeblade fuse blocks
Technical Data10488 SupersedesFebruary 2016 Class J modular ferrule and knifeblade fuse blocks Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15
More informationLow Voltage, Branch Circuit Rated Fuses
Low Voltage, Branch Circuit Rated Page Fuse Holder & Block Selection Guide 8-20 Class Fuse Dimensions 2-22 By Fuse Class Class Volts Low Voltage Branch Circuit CC...... LP-CC............... 600V..... 23
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS
More informationNH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3
IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,
More informationup to 30A limited by conductor size Operating and storage temperature:
Technical Data 7 USSMNN Effective pril 07 Supersedes December 05 SERIES HE breakaway and non-breakaway in-line fuse holders for UL 3/3 x -/ supplemental fuses Use these part numbers to order insulating
More informationSelf-protected Combination Starters System PKZ 2-SP
Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller
More informationClass R 250V and 600V modular ferrule and knifeblade fuse blocks
Technical Data 1048 Class R 2V and 600V modular ferrule and Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with up to four mounting holes per pole
More informationBulletin 194R Next Generation Global Fused and Non-Fused Disconnects
Bulletin R IE Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - SA HRII- - SA HRI-MIS - UL lass
More informationG eneral Purpose Fuses
G eneral Purpose Fuses North American Power Fuses AMP-TRAP2000 AMP-TRAP2000 AJT Class J - Time Delay 1 to 600A - - Motor, motor controller, control transformer, and circuit back-up protection. Space saving
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have
More informationLow Voltage Fuses General information
General information Description FUJI low voltage current-limiting fuses are designed to give protection to power supply and distribution circuits and equipment such as motor starter and semiconductors.
More information194R J S TY N1
Bulletin R IE Fused and Non-Fused Disconnects, & A Product Selection omplete UL/SA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA
More information9070T150D1 Industrial Control Transformer, 150VA
Product Data Sheet 9070T150D1 Industrial ontrol Transformer, 150 Technical haracteristics Application Approvals atalog Reference Number Depth Height Width Winding Material Temperature Rise Type Primary
More informationFuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.
Fuseology Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression Optima Fuse Holders & Overcurrent Protection Modules Compact, full-featured modules that deliver Type 2 coordinated protection,
More informationBUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:
Supersedes January 204 BUSSMANN SERIES LIMITRON FNQ-R Class CC 600Vac, 4-30A, time-delay fuses Catalog numbers (amps) FNQ-R- 4 FNQ-R--3 FNQ-R-3-2 FNQ-R-8 FNQ-R-3 FNQ-R--4 FNQ-R-3-2 FNQ-R-9 FNQ-R-4 FNQ-R--
More informationFuseology. Dual-Element, Time-Delay Fuse Operation
Dual-Element, Time-Delay Fuse Operation There are many advantages to using these fuses. Unlike single-element fuses, the Cooper Bussmann dual-element, time-delay fuses can be sized closer to provide both
More informationNH-Fuse system Low voltage
38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories
More informationThe easiest and fastest way to select and specify the right fuse
Fuses Made Simple BUSSMANN SERIES The easiest and fastest way to select and specify the right fuse Fuse selection made simple Fuses Made Simple with Bussmann series fuses Three tiers of protection help
More informationBritish BS 88 Fuses. High Speed Fuses. Introduction. General Information
British BS 88 Fuses Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 15-17 90-78-1 Accessories Indicator System & Fuse Bases British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationPSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES
PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available
More informationEDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards
-P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit
More informationMicroswitches M series
Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are
More informationNH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3
NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationMount Fuses. Maximum Protection. Minimum Space. C Midget, Miniature & PC. Mount Fuses
Midget, Miniature & P Mount Fuses Maximum Protection. Minimum Space. Your problem: As different as their job descriptions are on paper today s maintenance crews, specifying engineers, and OEM designers
More informationFull range of small dimension fast-acting and time-delay fuses
Electronic, PCB and small dimension fuses 3 Contents Product Catalog symbol/type Fuses C515, C519 time-delay 5x15mm fuses C518, C520 fast-acting C517 fast acting GDB, S500, S500-V fast-acting IEC 5x20mm
More informationCUBEFuse. CUBEFuse catalog numbers (amps)
The power of space CUBEFuse The revolutionary Bussmann TM series Low-Peak TM CUBEFuse TM delivers the smallest footprint compared to any Class CC, J or RK fuse solution requiring up to 70% less space when
More informationAccessories. For product data sheets, visit
British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationMoulded Case Circuit Breakers
Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationA200 NEMA Contactors and Starters A200
Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws
More informationP Series. UL Recognized CSA Certified VDE Approved. P Series. CORCOM Product Guide
OROM Product Guide The HMELEON daptable Module for General, High Performance or Medical pplications UL Recognized S ertified VE pproved PS PS000SS30 PS The P series power entry module offers fuller flexibility
More informationGE Consumer & Industrial. M-PACT New Air Circuit Breaker A
GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State
More informationNEMA Contactors & Starters A200
March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product
More informationBussmann series Quik-Spec Coordination Panelboard
Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects
More informationThe easiest and fastest way to select and specify the right control circuit fuse
Fuses Made Simple TM - Control Circuits BUSSMANN SERIES The easiest and fastest way to select and specify the right control circuit fuse Fuses Made Simple TM - Control Circuits Eaton's Bussmann series
More informationNH DIN Dual Indication Fuse Links
Class gg/gl, 400Vac, 2 to 630 Amps, Sizes 000 to 3 Standards/Approvals IEC 60269, VDE 0636, DIN 43620 Part 1 and 3 Description A square bodied range of industrial fuse links for a wide variety of applications.
More informationgg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES
, am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator
More informationNH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series
Description: A range of Class am square bodied industrial fuse links for a wide variety of motor protection applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhm(size)b-690 am
More informationD Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES
D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES Ferraz Shawmut D fuse-links, also called Diazed type, are 500 Volts AC rated with 75kA interrupting
More informationFUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A
Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong
More informationInternational products
Section Overview With over 25 locations around the globe, Littelfuse is the supplier of choice when it comes to international fuses, fuseholders and accessories. With an ever expanding portfolio of products
More informationProducts for enhancing electrical safety and reliability
Circuit protection solutions BUSSMANN Products for enhancing electrical safety and reliability SERIES Advantages of Bussmann series fused circuit protection Bussmann series fuses are worry-free: High interrupting
More informationLOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A
Bussmann LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt 601-2000A Dimensional Data All other lerances (± 0.02) 0.63" (± 0.03) All Slots and Holes 10.75" (± 0.09) 8.63" (± 0.09) 6.75" 5.75" 601A 800A
More informationBussmann NH Bases. Technical Data Effective October Product description: Standard features:
Technical Data 10163 Bussmann NH Bases Product description: Bussmann s range of NH bases has been designed with thermoplastic bodies, DIN-Rail and/or screw mounting (size 4 screw mounting only). This range
More informationD-73P disconnect and bypass switches
Switches atalog Data 008005EN Supersedes pril 2016 OOPER POWER SERIES D-73P disconnect and bypass switches ontents Description Page D-73P disconnect switch....2 D-73P3 bypass switch....5 D-73P-D cutout
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually
More informationPANEL PANEL MOUNTING COMPONENTS
PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology
More information28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description
.1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is
More informationFuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:
More informationCYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC
fuses 02 gg 04 am gg Cylindrical fuse links gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube
More informationVolts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:
Technical Data 7 Effective December 05 Supersedes October 05 USSMNN SERIES HE breakaway and non-breakaway in-line fuse holders for UL 3/3 x -/ supplemental fuses Symbol: HE* Description: The ussmann series
More informationRotary Cam Switches. Rotary Cam Switches
Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit
More informationEEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2
atalog: 16541 Issue ate: 6.11 Including the S/S and H/H Models ost-effective MI Power Inlet Filter UL Recognized S ertified V pproved 2 / 2 1 / 1 P / P Series ompact single stage MI filter with I 63-1
More informationNH Bases BUSSMANN SERIES. Technical Data Product description. Standard features
Supersedes August 2017 BUSSMANN SERIES Product description Eaton s Bussmann series have been designed with thermoplastic bodies DIN-Rail and/or screw mounting (size 4 screw mounting only). This range comes
More informationShort Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead
, am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or
More informationNH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a
LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationFor the most up-to-date information
www.square.com or the most up-to-date information Thermal-magnetic Molded ase ircuit reakers, 2 mpere rame lass 5,, 734, 8 IL3 JL 3-pole circuit breaker -frame, Thermal-magnetic ( Vac) mpere Magnetic Trip
More informationFull range of small dimension fast-acting and time-delay fuses. 5x15 mm 5x20 mm IEC 5x20 mm UL 1/4 x 5/8 1/4 x 7/8 1/4 x 1 1/4 x 1-1/4
Electronic, PCB and small dimension fuses 3 Contents Full range of small dimension fast-acting and time-delay fuses 5x15 mm 5x20 mm IEC 5x20 mm UL 1/4 x 5/8 1/4 x 7/8 1/4 x 1 1/4 x 1-1/4 PLUS PCB fuse
More informationNH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a
NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium
More information