1 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection of cables and LV-networks) The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gg NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. TECHNICAL DATA OVERVIEW Voltage AC 5 VAC Voltage DC 25 VDC Ampere Range (A) A Size per Standard 4, 4a Speed/Characteristic gg I.R. AC (IEC) 12 ka I.R. DC (IEC) 7 ka Body Material ceramic Contact Materials copper, silver-plated STANDARDS IEC/EN and -2 VDE 636 Part 21 EP.MERSEN.COM 1
2 PRODUCT RANGE Size 4 gg 5VAC top indicator Catalog Item AC (IEC) DC (IEC) Rated current In Power dissipation at In Width Package Weight NH4GG5V125-8 NH4GG5V63-8 X V 25 V 63 A 38 W 1 mm kg NH4GG5V8-8 Y V 25 V 8 A 56 W 1 mm kg NH4GG5V-8 Z V 25 V A 65 W 1 mm kg NH4GG5V125-8 A V 25 V 125 A 61 W 1 mm kg Size 4a gg 5VAC top indicator Catalog Item AC (IEC) DC (IEC) Rated current In Power dissipation at In Width Package Weight NH4AGG5V16-8 NH4AGG5V4-8 B V 25 V 4 A 31 W 98 mm kg NH4AGG5V5-8 C V 25 V 5 A 45 W 98 mm kg NH4AGG5V63-8 D V 25 V 63 A 47 W 98 mm kg NH4AGG5V8-8 F V 25 V 8 A 67 W 98 mm kg NH4AGG5V-8 H V 25 V A 69 W 98 mm kg NH4AGG5V125-8 J V 25 V 125 A 84 W 98 mm kg NH4AGG5V16-8 K V 25 V 16 A 16 W 98 mm kg TECHNICAL DATA size 4 size 4a Rated current A A Rated breaking capacity AC 12 ka 12 ka AC 5 V 5 V DC 25 V 25 V Indication System top indicator top indicator Width 1 mm 1 mm EP.MERSEN.COM 2
3 TIME CURRENT CHARACTERISTIC CURVES Size 4, A Size 4a, 4-16A Pre-arcing time (s) A 8 A A 125 A 1 16 A RMS value of prospective current (A) +/- 8% EP.MERSEN.COM 3
4 CUT-OFF CURRENT CHARACTERISTIC Size 4, A Size 4a, 4-16A 3 2 lm = 2.3 lp 16 A 125 A Maximum peak let thru current Ic (A) Hz RMS symmetrical prospective current Ip (A) A 8 A 63 A 5 A 4 A 3 5 5e+6 7 1e+6 PRE-ARCING AND OPERATING I²T CHARACTERISTICS Size 4, A Size 4a, 4-16A Pre-arcing and operating I²t (A²s) V 4V pre-arcing I²t Rated current (A) EP.MERSEN.COM 4
5 DIMENSIONS Size 4 with top indicator Indicator lever visible when the fuse has blown 68.5 ± ± (9) 32 ±.4 5 ± ± ±.4 16 ± (79.5) ± ± Dimensions in mm EP.MERSEN.COM 5
6 DIMENSIONS Size 4a with top indicator Indicator lever visible when the fuse has blown (51) ± ± (51) ±.1 Dimensions in mm 5 ± EP.MERSEN.COM 6
NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a
NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium
More informationNH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3
NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS
More informationNH fuse-links am VAC with striker, size 0, 1, 2, 3, 4
NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,
More informationNH fuse-links am 690VAC top indicator/live tags size 4, 4a
NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %
More informationNH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3
IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade
More informationProtistor size 70 gr 690VAC (IEC)
Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination
More informationNH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a
NH fuse-links gtr 400VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers
More informationProtistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 14x51 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor
More informationNEOZED D0 fuse-links gg 400/440VAC
NEOZED D0 fuse-links gg 400/440VAC LOW VOLTAGE IEC FUSES DIN LV FUSE-LINKS D0 FEATURES & BENEFITS The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non
More informationLimitor -G General Purpose Fuses
Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear
More informationProtistor size 31 ar 690VAC (IEC) / 700VAC (UL)
Protistor size 31 ar SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination ar Class according to IEC
More informationgi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories
,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker
More informationHelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC
SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection
More informationgg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES
, am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator
More informationShort Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead
, am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or
More informationProtistor size 120 gr 750VDC (IEC)
Protistor size 12 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS DC PROTECTION FEATURES & BENEFITS Multiple body sizes and terminals or blades combination Very low I²t Extremely fast
More informationFuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:
More informationLOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM
NH SIBA NH Fuse-links with top and center indicator are available in a large variety of voltage ratings, body sizes and operating classes: Sizes: 000, 00, 0, 1, 2, 3 and 4 Voltage ratings: AC 400 / 500
More informationD Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES
D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES Ferraz Shawmut D fuse-links, also called Diazed type, are 500 Volts AC rated with 75kA interrupting
More informationHelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC
SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection
More informationNH DIN Dual Indication Fuse Links
Class of Operation gl/gg, 500V AC, 10 to 630 s Sizes 000 to 3 Standards/ Approvals: Description: Packaging: IEC 60269, VDE0636, DIN 43 620 1 to 4. A square bodied range of industrial fuse links for a wide
More informationFuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4
URB Fuses for Semiconductor Protection European Standard Sizes 000 and 00 Class: ar Voltage ratings: AC 660 V AC 1000 V Current ratings: 16 A to 400 A Approvals: Standards: DIN 43653 IEC 60269-1 and -4
More informationMULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole
MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple
More informationLINOCUR Size D02 63A 230VAC/440VAC
IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated
More informationSection ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES
Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES TECHNICAL SPECIFICATIONS L.V- HRC KNIFE (NH TYPE) FUSE-LINKS ( V.AC) HRC knife fuse-links (NH Type) must have a rated breaking capacity current of
More informationMULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole
MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed
More informationNH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series
Description: A range of Class am square bodied industrial fuse links for a wide variety of motor protection applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhm(size)b-690 am
More informationnew NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price
NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high
More informationNH HRC Fuses. IEC & British Standard Fuses NHG B
NH HRC Fuses NHG B Specifications Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact,
More informationLENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES
LENRK/LESRK CLASS RK Catalog Number LENRK (. - 0A) 50 Volts AC or Less Catalog Number LESRK (.5-0A) 0 Volts AC or Less S LENRK 50V 0..5 75 0..5 5 0..5 9 50 5 0.5 50 0.. 70 0 0..5 5 0 50 7.5 90 0..5 0 50.
More informationSemiconductor Fuses European Fuses
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection - rated current (or ) I N - pre-arcing I²t (I²t p ) at ms - total ope I²t (I²tt) at 66 V, cos
More informationonlinecomponents.com
66 grb 66 V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: Fuse preselection Rated current Pre-arcing I²t Total I²t at 66VAC I N (A) I²t p (A²s) I²t (A²s) - rated current
More informationHelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC
HelioProtection HP15NH3L SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH3L photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic
More informationMULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole
MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple
More informationMULTIFIX 60 Universal Bus Bar Carriers
MULTIFIX MULTIFIX BUS BAR SYSTEMS COMPONENTS FOR MM SYSTEMS FEATURES & BENEFITS MULTIFIX is a system for energy distribution comprising a variety of modular combinable components. The energy distribution
More informationBussmann series NH catalogue. Leadership in circuit protection
Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places
More informationNH Dual NHIndicator Fuse System Fuse System
NH Dual NHIndicator Fuse System Fuse System Product Product Guide Guide NH Dual Indicator System Catalogue NH Dual Indicator Fuse System Class gg/gl - 400Vac - 2 to 60 Amps - s 000 to Part Numbers 400Vac
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution for all applications. Only Eaton
More informationMULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole
MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Learn more at Eaton.com/Cooper Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution
More informationIEC Low Voltage Products Module 4
IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More informationBSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC
BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC FUSE RAILS IEC NH FUSE RAILS FEATURES & BENEFITS Installation on to Dimensions of s and cable connections are equivalent to those of MULTIVERT APPLICATIONS
More informationNH Solid Blades 690 VAC sizes 000 to 3
NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a
More informationHHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear
HHB Medium Voltage Fuses British Standard For Oil Insulated Switchgears Introduction Medium voltage fuse-links according to British Standard are back-up fuse-links for the protection of substations up
More informationLPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse
LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)
More informationNH DIN Dual Indication Fuse Links
Class gg/gl, 400Vac, 2 to 630 Amps, Sizes 000 to 3 Standards/Approvals IEC 60269, VDE 0636, DIN 43620 Part 1 and 3 Description A square bodied range of industrial fuse links for a wide variety of applications.
More informationfuse-links & fuse holders PHOTOVOLTAIC
fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have
More informationHigh-voltage high-breaking capacity VV fuse-links
High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25
More informationMULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole
MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom
More informationLow voltage NH knife-blade fuse-links
Low voltage NH knife-blade fuse-links NV KOMBI advantages ETI is introducing a new generation of low-voltage fuse-links from size NV00C up to NV3 with new, dual indication of fuse-link operation, called
More informationEUROFUSE MULTIBLOC MULTIVERT D/D0-FUSE-SYSTEM BSL NH-FUSE-MATERIAL MULTIFIX 60 CYLINDRICAL FUSE-SYSTEM MINIATURE FUSE LINKS HIGH VOLTAGE FUSE LINKS
E UROFUSE 2007 EUROFUSE MULTIBLOC MULTIVERT D/D0-FUSE-SYSTEM BSL NH-FUSE-MATERIAL MULTIFIX 60 CYLINDRICAL FUSE-SYSTEM MINIATURE FUSE LINKS HIGH VOLTAGE FUSE LINKS EUROFUSE status 04/2007 Contents 3 Product
More informationRAPIDPLUS. high speed fuse links for semiconductors
high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS
More informationMULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole
MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom
More informationHHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.
HHD HIGH VOLTAGE GERMAN DIN STANDARD FOR AIR & GAS INSULATED SWITCHGEARS OUTDOOR SWITCHGEARS The striker pin system is connected by means of a high resistance parallel conductor. After melting the main
More informationPage 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.
Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated
More informationHHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.
HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After
More informationAmp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...
Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. A Your problem: You need maximum overcurrent protection to prevent costly damage to today s highly sensitive
More informationMedium voltage fuses Medium voltage fuses
European Fuses DIN Fuses 7.2kV - 36kV IBD 7.2 UP TO 36 KV HIGH-VOLTAGE FUSES DESIGNED FOR POWER TRANSFORMER PROTECTION INTERIOR/EXTERIOR USE CERAMIC HOUSING MEDIUM CLASS TRIP-INDICATOR COMBINED WITH A
More informationMULTIVERT 1000A Main Incomer, 690VAC
IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed
More informationGeneral Purpose IEC Fuses
Line protection fuses gl-gg IEC 60269 parts1, 3 and 3-1 DIN VDE 0636 Parts 10, 30 and 31 Dimensions are stipulated in the following regulations: DIN 49360 D Fuse-links DIN 49515 D Fuse-links DIN 49367
More informationGeneral Purpose US Fuses
SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides
More informationNH (H.R.C) FUSES AND FUSE BASES
NH (H.R.C) FUSES AND FUSE BASES NH (H.R.C) Fuses NHC-FB (A...A) NH-FB (A...A) NH-FB (A...A) NH-FB (8A...4A) NH-FB (A...A) NH-FB (A...A) NH (H.R.C) Fuse Bases STEATIT NH-FA NH-FA NH-FA NH-FA NH-FA CONTENTS
More informationSelector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits
Selector guide PSC Square body fuses Size 3X 500-700VAC End Contact Terminals December 2013 Issue 2 The IXYS UK range of 700V/690V protistor fuse links provides maximum flexibility in equipment design
More informationNH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW
FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC NH FUSE BASES FEATURES & BENEFITS Polyester insulating bases Silver-plated contacts High-pressure spring contacts Screw or rail mounting Multipolar bases available
More informationINNOZED D0 fuse-bases with touch protection
INNOZED D0 fusebases with touch protection INNOZED D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS INNOZED is a fuse base for D0 fuselinks,
More informationIEC Low Voltage General Purpose Protection
, 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6
More informationModulostar CMS10 Modular fuse-holders
Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC
More informationMedium Voltage current limiting Fuse links
Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 200A 1. General information P&C Medium Voltage fuse-links named PCEF are designed
More informationGMA GDB/GDA MDL MDA. Fuses SMALL DIMENSION. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price
SMALL DIMENSION GDB/GDA GMA Fast acting, low breaking Ceramic tube GDA only Glass tube with brass end caps GDB only.197"(5mm) x.788"(20mm) 250 volts AC or less UL Recognized, IEC 127-SI GDB10 Fast acting
More informationFuse holders and fuses
Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator
More informationRange : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions.
164 Fuse Holder consisting of carrier and base for mounting fuse links have been in use for long. Keeping operators safety and ease / reliability of removal in mind, a complete range of unique CAM operated
More informationUtilisation category gl/gg 500VAC with combi indicator
DIN-fuse-links DIN fuse-links are used for the protection of electrical installations and equipment and are common for a wide area of applications. Standardised characteristics, technical data and dimensions
More informationPSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES
PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available
More informationMedium Voltage current limiting Fuse links
Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 0A 1. General information P&C Medium Voltage fuse-links named PCEF are designed to
More informationBritish BS 88 Fuses. High Speed Fuses. Introduction. General Information
British BS 88 Fuses Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 15-17 90-78-1 Accessories Indicator System & Fuse Bases British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationInternational products
Section Overview With over 25 locations around the globe, Littelfuse is the supplier of choice when it comes to international fuses, fuseholders and accessories. With an ever expanding portfolio of products
More informationINNOZED D0 fuse-bases with touch protection
D0 fusebases with touch protection D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS is a fuse base for D0 fuselinks, sizes D0 and D02.
More informationHigh voltage high-breaking capacity VV fuse-links
High fuse-links High fuse-links High high-breaking capacity VV fuse-links VV General information ET fuse-links named VV THERMO are designed to protect devices in switch-gears and other equipment (distribution
More informationCS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES
SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced
More informationAccessories. For product data sheets, visit
British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationMM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s
Basic Efficiency up to 1500 V 1-pole 3-pole SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN successfully
More informationCL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES
SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as
More informationKLKD SERIES 10x38 FUSES
KLKD SERIES 0x FUSES 0 Vac/dc /0- A Fast Acting Description The KLKD fuse series is fast-acting with a high DC voltage rating. This family of Midget style fuses (0 x mm) is used in solar combiner boxes
More informationLow Voltage Products. HRC Fuse Links OFAFN_ and OFFN_ DIN and BS types, gg 500V 630A OFAFN 3. >80kA. 2 / gg MADE IN ABB
Low Voltage Products HRC Fuse Links OFAFN_ and OFFN_ DIN and BS types, gg OFFNC 2 OFAFN 3 3/gG Fuse protection - safe an 2A...1250 A, 500 V DIN-Type HRC fuse links (blade-type), 2A. DIN-size I n [A] S01350A
More informationURDC-PV. Features and Benefits FUSES. URPV Fuses for PV Semiconductor Protection. gpv. Class: Voltage ratings: 600V DC to 1500V DC.
Fuses for PV Semiconductor Protection Class: gpv 0 Voltage ratings: 600V DC to 1500V DC Current ratings: 1 A to 450 A Standards: UL 2579 IEC 60 269-6 Approvals: E341342 E341490 Features and Benefits High
More informationMULTIVERT 250A Size 1, 690VAC
MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.
More informationSurge-Trap Pluggable STPT2 Series - 40kA
Surge-Trap Pluggable STPT2 Series - 40kA SURGE PROTECTION FOR POWER LINES DIN-RAIL IEC TYPE 2 / CLASS II FEATURES & BENEFITS Maximum discharge current (8/20μs): 40kA per phase Nominal discharge current
More informationN0N A 250V One-Time Class H Fuse
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 AllenWatson@elliottelectric.com N0N 250V One-Time Class H Fuse Catalog Number Manufacturer Description Weight per unit
More informationControls HIGH SPEED FUSES
Controls HIGH SPEED FUSES 0800 367 934 High Speed Fuses HIGH SPEED FUSES Summary High Speed Fuses 4 Time vs. Current Curves 7 Current limitation curves 11 High Speed Fuses 15 Accessories 17 Dimensions
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationMEDIUM VOLTAGE DIN Fuse-Links
Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Catalogue Symbol: 24TDMEJ(amp) 24THMEJ(amp) 24TFMEJ(amp) 24TXMEJ(amp) Class of Operation: Back-up as IEC 60282-1
More informationSemiconductor (AC) fuses
x38 grb - 69VAC 69V AC grb - from up to 3 A Size: x38 The fuse preselection table below indicates: - rated current (or rating) I N - pre-arcing I 2 t (I 2 t p ) at ms - total operating I 2 t (I 2 tt) at
More informationW DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE
W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE W SCHRACK-INFO Combined RCD/MCB device Type-A: Protects against special forms of residual pulsating DC which have not been smoothed Line voltage-independent
More informationHV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017
HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH
More information34-SDMS-02 SPECIFICATIONS FOR
SPECIFICATIONS FOR M V & L V FUSE LINKS This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE
More informationLPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 LPCC3 3A 600V TD Class CC Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPCC3
More informationClass gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series
Description: A range of Class gg/gl square bodied industrial fuse links for a variety of applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhg(size)b-690 gg/gl Fuse Size: 000 to
More information