IEC and British Standard Fuses.

Size: px
Start display at page:

Download "IEC and British Standard Fuses."

Transcription

1 IEC and British Standard Fuses Section Contents Page Application Data CSA Type P and Type D fuses (CDS, CDN & PON) Tron HRC Form II Class C fuses (CGL Form II Class C) HRCI Industrial ceramic body fuses (CIF HRCI-CA & CIF06 HRCI-CB) HRCI-J Fast-acting fuses (CJ HRCI-J) HRCI-Miscellaneous Type K fuses (CIH, CIK & CIL HRCI-MISC) HRC Form II current-limiting fuses BS 88 British Standard low voltage fuses (SSD, NSD, ESD & STD, NITD, AAO, BAO, OSD, CEO, DEO BS 88 Part ) BS 88 British Standard low voltage fuses (AC, AD, BC, BD, CD, DD, ED, EFS & EF, FF, FG, GF, GG, GH BS 88) DIN Style Type D (D6, D7, D, D5 Type D) Neozed low voltage fuses (NZ0, NZ0 Type D0) NH HRC Fuses Class gg/gl IEC Industrial ferrule fuses (C08G, C08M, C0G, C0M, C4G, C4M, CG, CM) Class am IEC Industrial ferrule fuses (C08M, C0M, C4M, CM) Class am & gg/gl IEC Industrial ferrule fuses with striker (C4G_S, CG_S, C4M_S, CM_S) HRC fuse holders CAMaster SAFEloc Scan this tag to get the latest product information for IEC and British Standard Fuses. Application Data The standard range of fuses for low voltage industrial and general purpose applications meet the requirements of BS 88 and IEC By using advanced fuse technology, current ratings up to 400A have compact dimensions, but retain standard dimensional and performance requirements. These designs are for 5/40V systems. The standard range of fuses are available from -50A in the following tag forms: Offset Blade - Offset Bolted - Center Bolted. Supplementary ranges cover applications up to 660Vac and 500Vdc including those with nonstandard tag fixings. Bussmann fuses are manufactured under quality systems independently assessed to BS 5750 (ISO 900) and appropriate ratings carry the ASTA 0 endorsement. Selecting fuses is relatively simple and effective. The following notes cover the majority of applications. For further information contact our Application Engineers at toll free phone: (855-BUSSMANN). Circuit Loading The current rating of the fuse should not be less than the full load current of the circuit. The circuit should be so designed that small overloads of long duration will not be of frequent occurrence. Cable Ratings & Protection There is an increasing move away from 70 C PVC insulation to materials that are more environmentally friendly, for example 90 C XLPE. The ratings of fusegear, switches, accessories, etc. are generally based upon the equipment being connected to conductors intended to be operated at a temperature not exceeding 70 C in normal service. In view of the above, it is recommended that the practice of designs based upon conductor temperatures of 70 C be regarded as the norm. The equipment manufacturer should be consulted to ascertain the reduction of nominal current rating of the equipment if conductor temperatures exceeding 70 C are used. In addition, an overriding factor is often voltage drop. Fuses with gg characteristics protect associated cables against both overload and short-circuit current, provided that the current rating of the fuse N is equal or less than the current carrying capacity of the cable z. In motor circuits, the motor starter will provide the overload protection and the fuses will provide the short-circuit protection. The maximum fuse size that can be used depends upon the type of cable used and is determined using the appropriate K factor. The following table gives the maximum sizes of fuses that are recommended for two popular cables with copper conductors, 70 C PVC (K = 5) and 90 C thermosetting (K = 4). IEC & British Fuses 45

2 Application Data for BS Low Voltage Fuses Max. Fuse Rating (amps) Cable Size (mm ) K = 5 K = 4 6 6,5 0 5*.5 * * 4 50* 50* 6 6* 6* 0 00* 5* 6 5* 60* 5 00* 50* 5 5* 55* * * Extended Motor Circuit dual ratings can be used. Protection Against Electrical Shock For a TN System, a disconnecting time not exceeding 5s is permitted for a distribution circuit. The maximum values of earth fault loop impedance (Zs) of 40V for Bussmann gg fuses to BS 88: Parts and 6 are: Rating (A) Zs (Ohms) Rating (A) Zs (Ohms) Rating (A) Zs (Ohms) Ambient Temperature The derating, in terms of current, of 0.5% per C above an ambient of 5 C is recommended. Interrupting Rating The standardized interrupting rating values are 80kA for voltages of 45Vac and above, and 40kA for DC applications. The 40Vac designs have an interrupting rating of 50kA. Coordination Ratio All fuses to BS 88 Parts and 6 will give a coordination ratio of :; and for most practical situations a ratio of.6: (two steps in the R0 series). Example: an upstream fuse rated at 60A will coordinate with a downstream fuse rated at 00A. Current and Energy Limitation The range of fuses have pre-arcing I t values towards the bottom limits of BS 88 Parts and 6. This ensures excellent current and energy limitation. They also have lower power losses at rated current. This assists in the appropriate interchangeability with other makes of fuses. Transformers When fuses are used on the primary side of transformers, the normal fuse current rating should be at least twice the nominal transformer primary current. Fluorescent Lighting The normal fuse current rating should be at least twice the normal full load current of the maximum number of lights to be simultaneously switched. Capacitor Circuits For power factor correction in capacitor circuits, the fuse should be chosen with a current rating greater than.5 times the rated capacitor current. This takes into account the high inrush current, circuit harmonics and capacitor tolerances. Motor Circuits In motor circuits, the fuse has to withstand the motor's starting current and often requires a higher rating than the motor's full load current. Coordination recommendations are made by the manufacturers of motor starters in accordance with IEC To get Type coordination with fuses, tests are performed with the latest gg or gm fuses to BS 88 or IEC 6069 that have pre-arcing I t values towards the bottom of specified limits. This means that Bussmann fuses are suitable to provide Type coordination. Extended dual ratings of motor circuit protection fuses with gm characteristics are available in most popular fuse sizes to extend the use of associated equipment with appropriate economies. In the majority of applications, gg fuses are used. It is not essential to use gm fuses for motor circuit protection, they simply extend the utilization of standard equipment. Below is a table of recommended fuses at 45V. In most applications, the run-up time is less than 5 seconds and duty is infrequent - no more than twice per hour. The next larger rating should be used for more demanding applications. Direct On-line Asst. Start Standard Motor Circuit Standard Rating Motor (gg) (gm) (gg) kw A A A A M M M M M M M M M M M M M M M M M

3 CSA Type P and Type D Fuses CDS, CDN & PON Type P & D Description: CSA time-delay Type D & P fuses. Dimensions: See table and Dimensions illustration. Volts: 50Vac (CDN & PON) 600Vac (CDS) Amps: 0-600A IR: 0kA minimum Agency Information: CE, CSA Certified to C. No Features and Benefits Economical fuse in a variety of ratings for applications not requiring time-delay. Typical Applications Lighting, heating and other circuits not subject to temporary surges and where available short-circuit current are relatively low. Dimensions A B Basic Time-Delay CSA Type D Fuses Catalog Numbers Volts Amp Ratings Below 0A use FRN-R 0,, 5, 0, 5, 0, 5, 40, 45, 50, 60, 70, 80, 90, 00 CDN 50Vac 0, 5, 50, 75, 00, 5, 50, 00, 50, 400, 450, 500, 600 Below 0A use FRS-R 0,, 5, 0, 5, 0, 5, 40, 45, 50, 60 CDS 600Vac 70, 80, 90, 00, 0, 5, 50, 75, 00, 5, 50, 00, 50, 400, 450, 500, 600 Ferrule Design through 60A C A D Knife Blade 70 through 600A F B E One-Time CSA Type P Fuses Catalog Number Volts Amp Ratings PON 50Vac 5, 0, 5, 0, 5, 40, 45, 50, 60 Basic Catalog Dimensions in (mm) Number Amp A B Max C Min D Min E F and Volts Ratings Overall Diameter Blade Length Barrel Length Blade Thickness Blade Width -0.0 (50.8) 0.56 (4.) (76.) 0.8 (0.6) CDN/PON 50Vac (49.4).0 (5.4) 0. (.) 0.75 (9.) (85.4).8 (4.9) 4. (04.8) 0.9 (4.8). (8.6) (9.).88 (47.6) 4.6 (7.5) 0.5 (6.4).6 (4.) (6.7).5 (57.) 5.9 (.8) 0.5 (6.4) (50.8) (7.0) 0.8 (0.6) (9.7).06 (7.0) CDS 600Vac (00.).0 (5.4) 0. (.) 0.75 (9.) (44.6).8 (4.9) 6. (5.6) 0.9 (4.8). (8.6) (95.4).88 (47.6) 7. (8.) 0.5 (6.4).6 (4.) (9.9).5 (57.) 8.9 (08.0) 0.5 (6.4) (50.8) To Order To order, specify Basic Catalog Number and amp rating. Example: CDN-0 IEC & British Fuses Data Sheet: 46 47

4 Tron HRC Form II Class C Fuses CGL Form II Class C Description: Current-limiting HRCII-C fuses designed to withstand inrush currents on typical motor start-ups while offering high current limitation in the short-circuit region. Dimensions: See Dimensions illustrations. Volts: 600Vac/50Vdc (-0A) Amps: -600A IR: 00kA (40,000A DC) Agency Information: CE, CSA Certified, C. No. 06. Features and Benefits Close sizing to loads allows using smaller and less costly switches Provides a higher degree of short-circuit protection Helps protect motors against burnout from overloads Typical Applications For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads (-Amps) CGL- CGL-40 CGL-75 CGL- CGL-45 CGL-00 CGL- CGL-50 CGL-5 CGL-4 CGL-60 CGL-50 CGL-6 CGL-70 CGL-00 CGL-0 CGL-80 CGL-50 CGL-5 CGL-90 CGL-400 CGL-0 CGL-00 CGL-450 CGL-5 CGL-0 CGL-500 CGL-0 CGL-5 CGL-600 CGL-5 CGL-50 Dimensions CGL -0 CGL 5-60 CGL CGL " 0." (5.56mm) (5.56mm).0" (50.8mm).80" (7.04mm)." (84.4mm) 0." 0." (5.56mm) (5.56mm).0" (50.8mm).80" (7.04mm).5" (88.9mm) 0.4" (8.7mm).9" (60.7mm).64" (9.47mm) 4." (09.54mm) 0.4" (8.7mm) 0.8" (9.5mm) 0.8" (0.64mm) 0.4" (8.7mm) 0.50" (.7mm) 0.4" (8.7mm).00" (76.mm) 4.0" (09.mm) 5." (4.87mm) 0.8" (0.64mm) 0.75" (9.05mm) 0.4 (8.7mm) 0.06" (.59mm) 0.94" (.8mm).4" (4.04mm) 0.06" (.59mm).06" (6.9mm) 0.75" (9.05mm) 0.09" (.9mm).75" (4.9mm).50" (8.mm).0" (5.4mm) 0.5" (.8mm) 0.9" (4.76mm).0" (76.mm) 5.5" (.5mm) 8.9" (07.96mm).0" (5.4mm).8" (60.mm) CGL " (0.mm).0" (5.4mm).0" (5.4mm).0" (76.mm) 5.5" (.5mm) 8.9" (07.96mm).60" (5.4mm) 0.75" (9.5mm).00" (76.mm) CGL Data Sheet: 45 48

5 HRCI Industrial Ceramic Body Fuses CIF HRCI-CA Description: The HRCI-CA fuse provides both overload and short-circuit protection to HRCI requirements. Offset blades for bolt-on mounting. CIF fuse fits the Cooper Bussmann CAMaster fuse holder (see data sheet 4). Dimensions: See Dimensions illustration. Construction: Ceramic body. Volts: 600Vac/50Vdc Amps: -0A IR: 00kA RMS Sym. Agency Information: CE, CSA C., No. 06-M9. Mounting: Bolt-on. Catalog Amp Numbers Ratings CIF CIF 6CIF 6 0CIF 0 5CIF 5 0CIF 0 5CIF 5 0CIF 0 Features and Benefits Close sizing to loads allows using smaller and less costly switches Provides a higher degree of short-circuit protection Helps protect motors against burnout from overloads Typical Applications For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads Dimensions - in (mm).5 (54.5).44 (5.5) CIF06 HRCI-CB Description: A miniature industrial fuse that provides both short-circuit and overload protection and the CIF06 fits the 0A SAFEloc fuse holder. Dimensions: See Dimensions illustration. Construction: Ground ceramic body with plated end caps. Volts: 600Vac/50Vdc Amps: -0A IR: 00kA RMS Sym. Agency Information: CE, CSA C. No. 06-M9 (-0A only). Mounting: Clip-in offset blades. Catalog Number Catalog Amp Numbers Ratings CIF06 CIF06 6CIF06 6 0CIF06 0 5CIF06 5 0CIF06 0 5CIF06 5 0CIF06 0 Features and Benefits Close sizing to loads allows using smaller and less costly switches Provides a higher degree of short-circuit protection Helps protect motors against burnout from overloads Typical Applications For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads Dimensions - in (mm).8 (60.4).44 (5.5) IEC & British Fuses 0.9 (4.7) 0.54 (.8) 0.44 (.) 0.54 (.8) 0.5 (.7) 0.0 (.5).75 (44.5) 0.0 (0.8) 0.4 (.5) Data Sheet: 47 Data Sheet: 48 49

6 HRCI-J Fast-acting Fuses CJ HRCI-J Dimensions Description: HRCI-J fast-acting fuses are industrial duty fuses with the excellent current-limiting characteristics of fast-acting HRCI-J fuses to limit damage to equipment and installations by the thermal and magnetic energy associated with a large short-circuit fault current. Overload characteristics limit cable damage due to low overload currents. Dimensions: See table and Dimensions illustrations. Construction: Ceramic body fuse. Volts: 600Vac (or less), 50Vdc Amps: -600A IR: 00kA Agency Information: CSA C. No. 06 M9; Designed to BS 88:, IEC CJ to 60CJ C 70CJ to 600CJ C E D B J A B A K B F G H Catalog Amp Dimensions - in (mm) Numbers Ratings A B C D E F G H J K CJ CJ 6CJ 6 0CJ 0 5CJ 5.5 (57) 0.5 (.7) 0.8 (0.6) 0CJ 0 5CJ 5 0CJ 0 5CJ 5 40CJ 40 45CJ 45.8 (60) 0.6 (6).06 (7) 50CJ 50 60CJ 60 70CJ 70 80CJ 80 90CJ (7).6 (9). (8) 0.75 (9) 0. (.) (5.4) 0.5 (.7) 0.8 (7.) 0.8 (9.5).6 (67) 00CJ 00 0CJ 0 5CJ 5 50CJ (46) 4.8 ().6 (4). (8.6) 0.9 (4.8).8 (5) 0.69 (7.5) 0.8 (7.) 0.8 (9.5) (76) 75CJ 75 00CJ 00 5CJ 5 50CJ 50 00CJ (8) 5.5 (). (54).6 (4) 0.5 (6.).88 (47.6) 0.94 (4) 0.4 (0.) 0.5 (.5).8 (86) 50CJ CJ CJ CJ (0) 6 (5).6 (66) (5) 0.8 (9.5). (54) (5.4) 0.5 (.5) 0.69 (7.5).75 (96) 600CJ 600 Data Sheet: 49 50

7 HRCI - Miscellaneous Type K Fuses CIH, CIK & CIL HRCI-MISC Description: HRI fuses provide both overload and short-circuit protection, featuring offset blades for bolt down mounting. Dimensions: See table and Dimensions illustration. Construction: Ceramic body. Volts: 600V Amps: -00A IR: 00kA@600V Agency Information: CE, CSA C. No. 06 M9. Dimensions D K F A G J E G L H C (The CIL4 has a rejection hole, not a slot as shown above.) B Catalog Amp Dimensions - in (mm) Numbers Ratings A Max B Max C Max D Nom E Nom F Nom G Nom H Nom J Max K Nom L Max CIH07.5 (57) 0.94 (4).8 (86) 0.8 (9.) 0.04 (.0).88 (7) 0. (5.) 0. (8) (5.4) 0.0 (.6).8 (60) CIH07 6CIH07 6 0CIH07 0 5CIH (57) 0.94 (4).8 (86) 0.8 (9.) 0.04 (.0).88 (7) 0. (5.) 0. (8) (5.4) 0.0 (.6).8 (60) 0CIH07 0 5CIH07 5 0CIH07 0 5CIK (58).06 (7).56 (9) 0.5 (.7) 0.05 (.).88 (7) 0. (5.) 0.4 (0.5).09 (8) 0. (.).8 (6) 40CIK CIK (58).06 (7).56 (9) 0.5 (.7) 0.05 (.).88 (7) 0. (5.) 0.4 (0.5).09 (8) 0. (.).8 (6) 60CIK CIL (70).44 (7) 4.8 () 0.75 (9) 0.09 (.5).69 (94) 0.4 (8.7) 0.4 (0.5).5 (8.5).9 (74) 90CIL (70).44 (7) 4.8 () 0.75 (9) 0.09 (.5).69 (94) 0.4 (8.7) 0.4 (0.5).5 (8.5).9 (74) 00CIL4 00 IEC & British Fuses Recommended Fuse Holders Fuse Fuse Holder -0A CM0CF 5-60A CM60CF Data Sheet: 40 5

8 HRC Form II Current-limiting Fuses HRC Form II Description: HRC Form II current-limiting fuses. Dimensions: See Catalog Numbers table and Dimensions illustrations. Construction: Ceramic body. Volts: 600Vac (or less) 50Vdc Amps: -600A IR: 00kA RMS Sym. Agency Information: CE, CSA C. No.06M99; BS 88:, IEC 6069:. Typical Applications Used to protect motor control circuits, together with contactors and overload protection relays to provide Type coordination - per IEC Dimensions F G A H C F A G H C C A H G F K F A G E D E D D K D J B J B E B B H07C (Offset Blades) K07C/K07CR/ L4C/M4C (Offset Blades) L09C/M09C/P09C (Center Blades) PC/RC (Center Blades) H E C Catalog Amp Dimensions - in (mm) Numbers Ratings A B C D E F G H J K CSA Category H07C.8 (5) 0.56 (4).8 (85) 0.8 (9) 0.06 (.).88 (7) 0. (5.6) 0. (8) 0.56 (4) HRCII-C 4H07C 4 6H07C 6 0H07C 0 5H07C 5.8 (5) 0.56 (4).8 (85) 0.8 (9) 0.56 (4) 0H07C 0 HRCII-C 5H07C (.).88 (7) 0. (5.6) 0. (8) 0H07C 0 40K07C 40.9 (56) 0.88 ().44 (87) 0.5 () 0.06 (.).88 (7) 0. (5.6) 0. (8) 0.88 () HRCII-C 50K07C (87) 60K07C 60.9 (56) 0.88 () 0.5 () 0.88 () 80K07CR 80.9 (56) 0.88 () (95) (95) 0.5 () 0.06 (.).88 (7) 0. (5.6) 0. (8) 0.88 () HRCII-MISC HRCII-MISC 00K07CR 00 80L4C (60) (60) (.4) (.4) 4.8 () (4.) (4.) (.) (.).69 (94) 0.4 (8.7) 0.44 () (5.4) (5.4) HRCII-C HRCII-C 00L4C 00 5M4C 5.56 (65).5 (8) 4.8 () 0.75 (9) 0.09 (.4).69 (94) 0.4 (8.7) 0.44 () HRCII-MISC 50M4C (65).5 (8) 0.75 (9) 0.09 (.4) 0.44 () 00M4C 00 HRCII-MISC 80L09C (60) (60) (.4) (.4) 5 5 (7) (7) (4) (4) 0. (.) 4.8 () 0.4 (8.7) 0.44 () HRCII-MISC 00L09C (8.7) 5M09C 5.56 (65).5 (8) 5.8 (6) 0.75 (9) 0. (.) 4.8 () 0.4 (8.7) 0.56 (4) HRCII-C 50M09C (65).5 (8) 0.75 (9) 0.56 (4) HRCII-C 00M09C () 50P09C (78). (59) 5.8 (6) (5.4) 0.9 (4.8) 4.8 () 0.4 (8.7) 0.5 () HRCII-MISC 00P09C 00 50P09C (4.8) 0.5 () HRCII-MISC 400P09C (5) 5.5 () 0.4 (0) 0.6 (6) (5) HRCII-C 50PC (78).06 (78). (59). (59) 8.5 (0) (5.4) 00PC 00 (5.4) 50PC (5) (5) 400PC (0) 5.5 () 0.4 (0) 0.6 (6) HRCII-C 450RC (8).88 (7) 8.5 (0) (5.4) 0.5 (6.) 5.5 () 0.4 (0) 0.6 (6) (5) HRCII-C 500RC (8).88 (7) 0.5 (6.) (5) 600RC 600 Data Sheet: 4 5

9 BS 88 British Standard Low Voltage Fuses SSD, NSD, ESD BS 88 Part Description: The NSD and ESD are low voltage fuses complying with general purpose gg characteristics. Construction: Ceramic body. Volts: Vac (See table) Amps: -6A (See table) 0M5-6M00A Motor Starter ratings (See table) IR: ka (SSD) 80kA (NSD, ESD) Agency Information: CE, Meets the requirements of BS 88 Part and IEC Mounting: Offset blades. Basic Basic Max AC Catalog Amp Voltage BS 88 Numbers Ratings Ratings Ref. SSD, 4, 6, 0, 6, 0, 5, 40 E NSD, 4, 6, 0, 6, 0, 5,, 550 F 0M5*, 0M*, 0M6*, M6*, M40*, 45 F M50*, M6* 45 F ESD, 4, 6, 0, 6, 5, 550 F 40, 50, 6, 6M80, 6M00* 45 F * M indicates motor starter ratings. To Order To order, specify Basic Catalog Number and amp rating. Example: SSD-0 Recommended Fuse Holders Basic Fuse NSD ESD Holder Catalog Numbers NNSF 6ENSF STD, NITD, AAO, BAO, OSD, CEO, DEO BS 88 Part Description: The STD to DEO types are low voltage fuses complying with general purpose gg characteristics. Construction: Ceramic body. Volts: Vac (See table) Amps: -00A (See table) 0M5-00M5A Motor Starter ratings (See table) IR: ka (STD) 80kA (NITD, AAO, BAO, CEO, DEO) Agency Information: CE, Meets the requirements of BS 88 Part and IEC Mounting: Offset bolted blades. Typical Applications The STD type are used in 40V street lighting cut-outs NITD to DEO types used for industrial and general purpose applications Basic Basic Max AC Catalog Amp Voltage BS 88 Numbers Ratings Ratings Ref. STD, 4, 6, 0, 6, 0, 5, 40 NITD, 4, 6, 0, 6, 0, 5, 550 0M5*, 0M*, M40*, M50*, M6* 45 AAO, 4, 6, 0, 6, 0, 5,, M40*, M50*, M6* 550 BAO 40, 50, 6, 6M80*, 6M00* 550 A CEO, 40, 50, 6, 80, A4 00M5*, 00M60*, 00M00* 45 A4 DEO 5, 60, 00, 00M50*, 00M5* 45 OSD 80, M5*, 00M60* 45 * M indicates motor starter ratings. To Order To order, specify Basic Catalog Number and amp rating. Example: BAO-6 Recommended Fuse Blocks & Holders Basic Fuse Block/Holder NITD CMFC AAO CMF BAO CM6F OSD CM00F CEO BH-0 IEC & British Fuses Data Sheets 405 (SSD), 400 (NSD) and 40 (ESD) Data Sheets 4 (STD), 406 (NITD), 409 (AAO), 4 (BAO), 407 (OSD), 45 (CEO) and 47 (DEO) 5

10 BS 88 British Standard Low Voltage Fuses AC, AD, BC, BD, CD, DD, ED, EFS BS 88 Description: Low voltage fuses that comply with general purpose gg characteristics and available up to 400A with two hole mount and up to 50A with four hole mount. Construction: Ceramic body. Volts: 45/550Vac, 50Vdc (See table) Amps: -400A (See table) 6M80-400M500A Motor Starter ratings (See table) IR: See table Agency Information: CE, Meets the requirements of BS 88 Parts and and IEC Mounting: Center bolted blades, two-hole mount. Basic Basic Interrupting Max Voltage Catalog Amp Ratings Ratings BS 88 Numbers Ratings AC DC AC DC Ref. AC, 4, 6, 0, 6, 0, 5, 80kA 40kA AD, 4, 6, 0, 6, 0, 5, 80kA 40kA BC 40, 50, 6 80kA 40kA M80*, 6M00* 80kA 550 BD 40, 50, 6 80kA 40kA CD 80, 00, 00M5*, 00M60*, 00M00*, 00M00* 80kA 45 B DD 5, 60, 00, 00M50*, 00M5* 80kA 45 B ED 50, 5, 55, 400, 5M400* 80kA 45 B 400M500* 80kA 550 B4 EFS 5, 60, 00, 50, 5 80kA 45 * M indicates motor starter ratings. EF, FF, FG, GF, GG, GH BS 88 Description: Low voltage fuses complying with general purpose gg characteristics and available up to 400A with two hole mount and up to 50A with four hole mount. Construction: Ceramic body. Volts: 45/550Vac, 50/400Vdc (See table for details) Amps: IR: See table Agency Information: CE, Meets the requirements of BS 88 Parts and and IEC69-. Mounting: Center bolted blades, four-hole mount. Basic Basic Interrupting Max Voltage Catalog Amp Ratings Ratings BS 88 Numbers Ratings AC DC AC DC Ref. EF 55, kA 45 C 400M500* 80kA 550 FF 450, 500, 560, 60 80kA 40kA C FG 450, 500, 560, 60 80kA 40kA GF 70, kA 40kA C GG 70, kA 40kA , 50 80kA 550 GH 70, 800, 000, 50 80kA 550 * M indicates motor starter ratings.* M indicates motor starter ratings. To Order To order, specify Basic Catalog Number and amp rating. Example: FG-450 To Order To order, specify Basic Catalog Number and amp rating. Example: BC-40 Recommended Fuse Blocks & Holder Basic Fuse AC AD BC BD CD DD ED Block/Holder BH-0 Modular fuse block 00DF Fuse holder BH-0 Modular fuse block 00DF-L 00DF-L 00DF-L BH- Modular fuse block Data Sheets 40 (AC), 4 (AD), 4 (BC), 44 (BD), 46 (CD), 48 (DD), 49 (ED) and 4 (EFS) Data Sheets 40 (EF), 40 (FF), 4 (FG), 40 (GF), 404 (GG) and 408 (GH) 54

11 DIN Style Type D and Neozed Low Voltage Fuses D6, D7, D, D5 Type D Description: DIN style Type D low voltage fuses. Dimensions: See Catalog Numbers table and Dimensions illustrations. Construction: Ceramic body. Volts: 500Vac Amps: -00A IR: 00kA Agency Information: CE, D type fuses complying with DIN 4960 Part and DIN 4955, operating class gl. Catalog Amp Dimension Color Figure Numbers Ratings D (mm) Code Number D6 6 Pink 4D6 4 6 Brown 6D6 6 6 Green 0D6 0 8 Red 6D6 6 0 Grey 0D6 0 Blue 5D6 5 4 Yellow D7 6 Pink 4D7 4 6 Brown 6D7 6 6 Green 0D7 0 8 Red 6D7 6 0 Grey 0D7 0 Blue 5D7 5 4 Yellow 5D 5 6 Black 50D 50 8 White 6D 6 0 Copper 80D Silver 4 00D Red Additional Fuse links: Quick acting fuselinks in body sized D6, D7, D and D5 rated -00A. Reference number suffixed Q, i.e. 0D7Q. Voltage rating 500V. Gauge rings and keys can also be supplied. NZ0, NZ0 Type D0 Description: Low voltage Neozed fuses suitable for use on 50Vdc systems. Dimensions: See table and Dimensions illustration. Construction: Ceramic body. Volts: 400Vac Amps: -6A IR: 00kA Agency Information: CE Catalog Amp Dimension Color Numbers Ratings D (mm) Code NZ0 Pink 4NZ0 4 Brown 6NZ0 6 Green 0NZ0 0 Red 6NZ0 6 Grey 0NZ0 0 5 Blue 5NZ0 5 5 Yellow 5NZ0 5 5 Black 50NZ White 6NZ0 6 5 Copper Dimensions - mm D 6 Dimensions - mm IEC & British Fuses Figure Figure Figure Figure 4 Data Sheet: 44 Data Sheet: 44 55

12 NH HRC Fuses NHG B Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact, silver-plated copper blades. Sizes: DIN 000 to 4. Selectivity Ratio: :.6 up to 500Vac. Volts: 500Vac/50Vdc 690Vac/50Vdc Amps: -50A IR: 0kA Frequency: 50Hz Operating Frequency: 45-6Hz Agency Information: IEC 6069, VDE066, DIN 460 Part to 4, VDE Mark and CE. Fuse Blocks Size SB00-D SB-D *, SB-D 0,, 0, Dimensions - mm Fuse a b c c D e e e e 4 f Size a (max) a a 4 (nom) (± 8) (nom) (nom) (max) (max) (max) (nom) (max) ± ±.5 49 ± ± ± ±.5 49 ± ± ± / / ± ± ±.5 68 ± ± ± ±.5 68 ± ± ± ±.5 68 ± ± ± ±.5 68 ± ± ± 75 6 ±.5 68 ± ± ± 75 6 ±.5 68 ± ± Data Sheet For detailed information, visit the Electrical IEC section at

13 NH HRC Fuses Rated gg/gl Dual Indicator Current Voltage Conducting Carton 500Vac / 50Vdc Size (Amps) Metal Gripping Lugs Quantity NHG000B 4 4NHG000B 6 6NHG000B 0 0NHG000B 6 6NHG000B 0 0NHG000B 5 5NHG000B 000 NHG000B 5 5NHG000B 40 40NHG000B 50 50NHG000B 6 6NHG000B 80 80NHG000B 00 00NHG000B NHG00B 60 60NHG00B 0 0NHG0B 6 6NHG0B 0 0NHG0B 5 5NHG0B NHG0B 5 5NHG0B NHG0B 50 50NHG0B 6 6NHG0B 80 80NHG0B 00 00NHG0B 5 5NHG0B 60 60NHG0B 0 0NHG0B 6 6NHG0B 0 0NHG0B 5 5NHG0B NHG0B 5 5NHG0B NHG0B 50 50NHG0B 6 6NHG0B 80 80NHG0B 00 00NHG0B 5 5NHG0B 60 60NHG0B 00 00NHGB 4 4NHGB 50 50NHGB 5 5NHG0B 40 40NHG0B 50 50NHG0B 6 6NHG0B 80 80NHG0B NHG0B 5 5NHG0B 60 60NHG0B 00 00NHG0B 4 4NHG0B 50 50NHG0B 5 5NHGB 55 55NHGB NHGB 50 50NHG0B 5 5NHG0B NHG0B NHG0B NHGB 60 60NHGB NHG4G NHG4G Single Indicator NHG4G Slotted End NHG4G Tags 50 50NHG4G IEC & British Fuses For detailed information, visit the Electrical IEC section at 57

14 NH HRC Fuses Rated gg/gl Dual Indicator Current Voltage Conducting Carton 690Vac / 50Vdc Size (Amps) Metal Gripping Lugs Quantity NHG000B NHG000B NHG000B NHG000B NHG000B NHG000B NHG000B-690 NHG000B NHG000B NHG000B NHG00B NHG00B NHG00B NHG00B NHG0B NHG0B NHG0B NHG0B NHG0B NHG0B NHG0B NHG0B NHG0B NHG0B NHG0B NHG0B NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB NHGB For detailed information, visit the Electrical IEC section at

15 NH Fuse Bases SB*-D, SB*-S Up to 690V / 60-50A Sizes 00, 0,,,, 4 Part Numbers Size Poles Current (Amps) Part Numbers DIN Screw Carton Compatible Quantity Fuse Size Description: NH fuse bases with thermoplastic bodies. DIN-Rail and screw mounting (siz e 4 screw fix). Range of protection accesories for live parts in order to obtain IP0 protection standard. Volts: up to 690Vac Amps: to 50A A 60A 50A 400A 60A SB00-D TB00-D TB00-D-IP0 SB0-D TB0-D SB-D TB-D SB-D TB-D SB-D TB-D 000 & & 0 & 0 & Applications: Protection of industrial circuits and electrical apparatus 4 50A Neutral SB4-S (Screw Connection only) 4 Standards and Approvals: IEC 6069, DIN 460 Size Current (Amps) Part Ref Carton Quantity NH00 60 SL00 NH0 60 SL0 NH 50 SL NH 400 SL NH 60 SL NH4 000 SL4 Fuse extraction handle Size Part Ref Carton Quantity C00- FEH Protection accessories Size Current (Amps) Separation Partition 4 Part Ref Carton Quantity Fuse Casing 5 Part Ref Carton Quantity Terminal Cover Part Ref Carton Quantity Part Ref Separator Carton Quantity IEC & British Fuses NH00* NH0 NH NH NH 60A 60A 50A 400A 60A SP00* SP0 SP- SP- SP FC00* FC0 FC- FC- FC CS00* CS0 CS CS CS BC00* BC0 BC- BC- BC IP Protection Kits Part Reference TB00-D-IP0 FPK0-P FPK-P FPK-P FPK-P * For single pole only Description Complete triple pole fuse base IP0 rated IP0 kit for TB0-D fuse base IP0 kit for TB-D fuse base IP0 kit for TB-D fuse base IP0 kit for TB-D fuse base Microswitch Part Ref Carton Quantity BVL-50 Microswitch suitable for the following NH Fuse links: Volts gg/gl Volts gg/gl and am Volts gg/gl and am For detailed information, visit the Electrical IEC section at 59

16 Class gg/gl IEC 6069 Industrial Ferrule Fuses 8 x mm: 400Vac, 0.5-5A 0 x 8mm: 500Vac, A 4 x 5mm: 400Vac - 500Vac - 690Vac, - 50A x 58mm: 400Vac - 500Vac - 690Vac, - 5A 60 For detailed information, visit the Electrical IEC section at

17 Class am IEC Industrial Ferrule Fuses - Class am IEC x mm: 400Vac, - 8A 0 x 8mm: 400Vac - 550Vac, 0.6-5A 4 x 5mm: 690Vac - 500Vac, A x 58mm: 400Vac - 500Vac - 690Vac, - 5A IEC & British Fuses Neutral Links For detailed information, visit the Electrical IEC section at 6

18 Class am & gg/gl IEC Industrial Ferrule Fuses with Striker Class gg/gl with Striker 4 X 5 X 58 Catalog Number Amp Watts Loss Voltage Interrupting With Striker Rating (W) (AC) Rating (ka) C4GS C4G4S C4G6S C4G8S C4G0S C4GS 0.88 C4G6S C4G0S 0. C4G5S 5.46 C4GS.04 C4G40S 40.4 C4G50S Catalog Number Amp Watts Loss Voltage Interrupting With Striker Rating (W) (AC) Rating (ka) CG4S CG6S CG8S CG0S CGS 0.8 CG6S CG0S 0.9 CG5S 5.5 CGS. CG40S CG50S CG6S CG80S CG00S CG5S X 5 X 58 Class am with Striker Catalog Number Amp Watts Loss Voltage Interrupting With Striker Rating (W) (AC) Rating (ka) C4MS C4MS 0.4 C4M4S C4M6S C4M8S C4M0S C4MS C4M6S 6.6 C4M0S 0. C4M5S 5.46 C4MS.04 C4M40S 40.4 C4M50S Catalog Number Amp Watts Loss Voltage Interrupting With Striker Rating (W) (AC) Rating (ka) CMS CM4S CM6S CM8S CM0S CMS CM6S 6. CM0S CM5S 5.5 CMS. CM40S CM50S CM6S CM80S CM00S CM5S For detailed information, visit the Electrical IEC section at

19 HRC Fuse Holders CAMaster Catalog Symbol: See table below. Description: The CAMaster HRC fuse holder features a unique cam-action for easy fuse removal while allowing significantly improved contact pressure between fuse carrier and base contact that enhances electrical performance. A range of lockable safety carriers for the fuse holder (catalog reference: LSC), are available. Volts: 690V Amps: 0-00A (See Catalog Number table for details) Agency Information: CE, CSA C. No. 9; IEC 69 AND BS 88. Mounting: 5mm DIN-Rail or single screw mounting. Catalog Amp Fuse Numbers Ratings Details For: Accepted CM0CF 0 HRCI-CA Applications _CIF CM0CF 0 _H07C CM60CF 60 HRCII Applications _K07C CM00CF 00 _K07CR Accessory for CAMaster Units Catalog Amp Fuse Holder Numbers Ratings Details Accepted 0BS 0 CM0CF BS 0 Back Stud CM0CF 60/00BS 60/00 CM60/00CF GLP All Ganging Link Kit -Pole NI All 660V Neon Indicator 0LSC 0 CM0CF 0LSC 0 Security Carrier with Clip CM0CF 60/00LSC 60/00A CM60/00CF SAFEloc Catalog Symbol: See table below. Description: The SAFEloc HRC fuse holders (for use with HRCI-CB fuses) provides a positive, stressfree fuse fitting and locks it in position to ensure safe insertion and withdrawal from the base. Base contacts are fully shrouded to help protect against electric shock. Shrouds utilize simple slide/snap action allowing access to the contact terminal screws. Volts: 600V Amps: 0-60A (See Catalog Number table for details) Agency Information: CE, Designed to accommodate the compact range of offset blade fuse to CSA C. No. 06, HRCI-CB. Mounting: 5mm DIN-Rail or single screw mounting. * Catalog Amp Fuse Numbers Ratings Connection Accepted C0F Front C0BS 0 Back _CIF06 C0FBS Front-Back C60F Front C60BS 60 Back EK-Amp C60FBS Front-Back *For use with HRCI-CB Fuses. IEC & British Fuses Data Sheet: 4 Data Sheet: 4 6

20 Quik-Spec coordination panelboards The new Quik-Spec coordination panelboard with a footprint up to 40% smaller than other fusible panelboards is now available up to 00A 64

NH HRC Fuses. IEC & British Standard Fuses NHG B

NH HRC Fuses. IEC & British Standard Fuses NHG B NH HRC Fuses NHG B Specifications Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact,

More information

Bussmann series IEC cylindrical fuses

Bussmann series IEC cylindrical fuses IEC and ritish Standard fuses 5 Contents ussmann series IEC cylindrical fuses Complete portfolio of 8-22 mm diameter Class am and Class gg cylindrical fuses for industrial applications escription Fuses

More information

Bussmann series IEC cylindrical fuses

Bussmann series IEC cylindrical fuses IE and ritish Standard fuses 5 ontents ussmann series IE cylindrical fuses Section page escription Fuses S Type P and fuses (N, S and PON) HR Form II lass fuses (GL) 3 HRI industrial ceramic body fuses

More information

Low Voltage Catalogue. Domestic Applications to BS1361 & BS1312. Consumer Unit Fuse Link 240V / 5-45 A. Plug Top Fuse Links 240V / 1-13A

Low Voltage Catalogue. Domestic Applications to BS1361 & BS1312. Consumer Unit Fuse Link 240V / 5-45 A. Plug Top Fuse Links 240V / 1-13A Domestic Applications to BS1361 & BS1312 Consumer Fuse Link 240V / 5-45 A Description: Cylindrical Fuse Links for domestic application according to BS1361 Volts: - 240V Amps: - 5-45A IR - 16.5kA Applications:

More information

Circuit Protection Solutions. Low Voltage Fuse Links Catalogue

Circuit Protection Solutions. Low Voltage Fuse Links Catalogue Circuit Protection Solutions Low Voltage Fuse Links Catalogue Table of Contents Domestic Applications to BS161 & BS11 Consumer Fuse Link 4 Plug Top Fuse Links 4 Industrial & Motor Applications to BS88

More information

Bussmann series NH catalogue. Leadership in circuit protection

Bussmann series NH catalogue. Leadership in circuit protection Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places

More information

Leadership in Circuit Protection

Leadership in Circuit Protection Leadership in Circuit Protection Bussmann is now a part of Eaton Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution for all applications. Only Eaton

More information

Leadership in Circuit Protection

Leadership in Circuit Protection Leadership in Circuit Protection Bussmann is now a part of Eaton Learn more at Eaton.com/Cooper Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution

More information

NH Dual NHIndicator Fuse System Fuse System

NH Dual NHIndicator Fuse System Fuse System NH Dual NHIndicator Fuse System Fuse System Product Product Guide Guide NH Dual Indicator System Catalogue NH Dual Indicator Fuse System Class gg/gl - 400Vac - 2 to 60 Amps - s 000 to Part Numbers 400Vac

More information

Low-Peak 600V Class RK1

Low-Peak 600V Class RK1 LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:

More information

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)

More information

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high

More information

4 Moulded Case Circuit Breakers XT1 5 Moulded Case Circuit Breakers XT2 - XT4 6 Moulded Case Circuit Breakers T5 - T6

4 Moulded Case Circuit Breakers XT1 5 Moulded Case Circuit Breakers XT2 - XT4 6 Moulded Case Circuit Breakers T5 - T6 Protection Circuit Protection Circuit Pages Content 1 Miniature Circuit Breakers S200 range B - C 2 Miniature Circuit Breakers S200 range D - K 3 Miniature Circuit Breakers S200 accessories & S800 C Series

More information

Bussmann NH Bases. Technical Data Effective October Product description: Standard features:

Bussmann NH Bases. Technical Data Effective October Product description: Standard features: Technical Data 10163 Bussmann NH Bases Product description: Bussmann s range of NH bases has been designed with thermoplastic bodies, DIN-Rail and/or screw mounting (size 4 screw mounting only). This range

More information

500 Volts gg/gl NH Fuse links

500 Volts gg/gl NH Fuse links Technical Data 101 Supersedes December 01 BUSSMANN SERIES Product description Eaton s Bussmann series 500 Volts NH square bodied industrial fuse links are suitable for a wide variety of applications. Standard

More information

Paramount HRC Cartridge

Paramount HRC Cartridge Paramount HRC Cartridge Eaton MEM HRC fuselinks are manufactured to exacting standards using precision assembly methods and undergo rigorous quality checking before dispatch including resistance testing

More information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)

More information

Accessories. For product data sheets, visit

Accessories. For product data sheets, visit British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90

More information

Low Voltage, Branch Circuit Rated Fuses

Low Voltage, Branch Circuit Rated Fuses Low Voltage, Branch Circuit Rated Page Fuse Holder & Block Selection Guide 8-20 Class Fuse Dimensions 2-22 By Fuse Class Class Volts Low Voltage Branch Circuit CC...... LP-CC............... 600V..... 23

More information

N0N A 250V One-Time Class H Fuse

N0N A 250V One-Time Class H Fuse 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 AllenWatson@elliottelectric.com N0N 250V One-Time Class H Fuse Catalog Number Manufacturer Description Weight per unit

More information

NH DIN Dual Indication Fuse Links

NH DIN Dual Indication Fuse Links Class gg/gl, 400Vac, 2 to 630 Amps, Sizes 000 to 3 Standards/Approvals IEC 60269, VDE 0636, DIN 43620 Part 1 and 3 Description A square bodied range of industrial fuse links for a wide variety of applications.

More information

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

British BS 88 Fuses. High Speed Fuses. Introduction. General Information British BS 88 Fuses Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 15-17 90-78-1 Accessories Indicator System & Fuse Bases British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90

More information

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses Technical Data 6 Supersedes August 2015 Low-Peak LPJ Class J 600Vac/Vdc, 1-60A, Catalog symbol: LPJ-(amp)SP (non-indicating) LPJ-(amp)SPI (indicating) Description: Bussmann series Ultimate protection LPJ

More information

NH LOW VOLTAGE a FUSE SYSTEM

NH LOW VOLTAGE a FUSE SYSTEM NH LOW VOLTAGE a FUSE SYSTEM NH DIN Low Voltage Fuse System from Cooper Bussmann High Breaking Capacity 400Vac, 500Vac and 690Vac Insulated Tag variants available Dual Indication VDE 066 Part 1 DIN 4 60

More information

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series Description: A range of Class gg/gl square bodied industrial fuse links for a variety of applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhg(size)b-690 gg/gl Fuse Size: 000 to

More information

HRC Fuse Links Low Voltage Industrial SAFECLIP. NH DIN Standard RED SPOT / SAFECLIP / NH

HRC Fuse Links Low Voltage Industrial SAFECLIP. NH DIN Standard RED SPOT / SAFECLIP / NH GE Power Controls HRC Fuse Links Low Voltage Industrial RED SPOT Standard RED SPOT 400 Series RED SPOT / SAFECLIP / NH SAFECLIP NH DIN Standard RED SPOT / SAFECLIP / NH RED SPOT / SAFECLIP / NH Low Voltage

More information

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in: Supersedes January 204 BUSSMANN SERIES LIMITRON FNQ-R Class CC 600Vac, 4-30A, time-delay fuses Catalog numbers (amps) FNQ-R- 4 FNQ-R--3 FNQ-R-3-2 FNQ-R-8 FNQ-R-3 FNQ-R--4 FNQ-R-3-2 FNQ-R-9 FNQ-R-4 FNQ-R--

More information

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FRNR400 400A 250V TD Class RK5 Dual Elem Fuse-Fusetron Catalog Number Manufacturer Description Weight per unit Product

More information

IGS-EL-002(0) National Iranian Gas Co. Research and Technology Management. Standardization Division IGS. Iranian Gas Standards.

IGS-EL-002(0) National Iranian Gas Co. Research and Technology Management. Standardization Division IGS. Iranian Gas Standards. IGS-EL-002(0) 1372 32 National Iranian Gas Co. Research and Technology Management Standardization Division IGS Iranian Gas Standards Specification for : : Fuse Links APPROVED Fax:(9821)-8487-8384 http://igs.nigc.ir

More information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 LPCC3 3A 600V TD Class CC Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPCC3

More information

Bussmann series NH bases

Bussmann series NH bases Supersedes October 2013 BUSSMANN Product description Eaton s range has been designed with thermoplastic bodies DIN-Rail and/or screw mounting (size 4 screw mounting only). This range comes with a accessories

More information

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses Technical Data1019 Supersedes July 2013 Fusetron FRN-R Class RK5 250Vac/125Vdc Catalog symbols: FRN-R-_ (non-indicating) FRN-R-_ID (indicating) Description: Eaton Bussmann series advanced protection, energy

More information

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series Description: A range of Class am square bodied industrial fuse links for a wide variety of motor protection applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhm(size)b-690 am

More information

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube 5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube Fast-acting, low breaking capacity Optional axial leads available 5 x 20mm physical size Glass tube with silver-plated (32-125mA) and nickel-plated (160mA-10A)

More information

IEC Low Voltage Products Module 4

IEC Low Voltage Products Module 4 IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!

More information

NH DIN Dual Indication Fuse Links

NH DIN Dual Indication Fuse Links Class of Operation gl/gg, 500V AC, 10 to 630 s Sizes 000 to 3 Standards/ Approvals: Description: Packaging: IEC 60269, VDE0636, DIN 43 620 1 to 4. A square bodied range of industrial fuse links for a wide

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules. Fuseology Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression Optima Fuse Holders & Overcurrent Protection Modules Compact, full-featured modules that deliver Type 2 coordinated protection,

More information

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3 IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

NH Bases BUSSMANN SERIES. Technical Data Product description. Standard features

NH Bases BUSSMANN SERIES. Technical Data Product description. Standard features Supersedes August 2017 BUSSMANN SERIES Product description Eaton s Bussmann series have been designed with thermoplastic bodies DIN-Rail and/or screw mounting (size 4 screw mounting only). This range comes

More information

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection

More information

Red Spot Fuse Holders

Red Spot Fuse Holders Finger-safe Fuse Holders for BS88 HRC Industrial Fuses Description A range of CSA certified IP20 finger-safe fuse holders for BS88 HRC industrial fuses in rating up to 400A. Catalog Symbol RS(AMP)(Connection

More information

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES LENRK/LESRK CLASS RK Catalog Number LENRK (. - 0A) 50 Volts AC or Less Catalog Number LESRK (.5-0A) 0 Volts AC or Less S LENRK 50V 0..5 75 0..5 5 0..5 9 50 5 0.5 50 0.. 70 0 0..5 5 0 50 7.5 90 0..5 0 50.

More information

International products

International products Section Overview With over 25 locations around the globe, Littelfuse is the supplier of choice when it comes to international fuses, fuseholders and accessories. With an ever expanding portfolio of products

More information

SINCE 989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

BS88 LV Fuse Links & Holders Catalogue Blue Dot

BS88 LV Fuse Links & Holders Catalogue Blue Dot BS88 LV Fuse Links & Holders Catalogue 009 Blue Dot Ferraz Shawmut Powerful presence of the world s leader on the circuit protection market Ferraz Shawmut, Carbone Lorraine s Electrical Protection Division,

More information

Complete and reliable solar circuit protection

Complete and reliable solar circuit protection Contents Photovoltaic fuses, holders, and blocks 6 Complete and reliable solar circuit protection Description Fuses Fuse size Volts Amps PVM 13/32" x 1-1/2" 600 4-30 PVS-R RK5 600 20-400 Section page PV-_A10_

More information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium

More information

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

Low voltage, branch circuit fuses

Low voltage, branch circuit fuses Low voltage, branch circuit fuses Contents Description Page Fuse holder and block selection guide -2 Class fuse dimensions -5 Fuses by fuse class Class Fuses Volts CC....... LP-CC............... 600V.....

More information

Fuseology. Dual-Element, Time-Delay Fuse Operation

Fuseology. Dual-Element, Time-Delay Fuse Operation Dual-Element, Time-Delay Fuse Operation There are many advantages to using these fuses. Unlike single-element fuses, the Cooper Bussmann dual-element, time-delay fuses can be sized closer to provide both

More information

CUBEFuse. CUBEFuse catalog numbers (amps)

CUBEFuse. CUBEFuse catalog numbers (amps) The power of space CUBEFuse The revolutionary Bussmann TM series Low-Peak TM CUBEFuse TM delivers the smallest footprint compared to any Class CC, J or RK fuse solution requiring up to 70% less space when

More information

Bussmann. Circuit Protection Solutions

Bussmann. Circuit Protection Solutions ussmann Circuit Protection Solutions ussmann Worldwide Circuit Protection Solutions World s leading supplier of fuses and fusible protection systems, ussmann continues its 88-year history of blazing new

More information

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES , am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

INDUSTRIAL CYLINDRICAL FUSE LINKS

INDUSTRIAL CYLINDRICAL FUSE LINKS gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Harmonization of IEC and North American Safety Standards

Harmonization of IEC and North American Safety Standards Equipment SCCR made easy Harmonization of IEC and North American Safety Standards Dan Neeser Field Application Engineer Eaton s Bussmann Division DanRNeeser@Eaton.com Agenda UL 508C, UL 61800-5-1 and transition

More information

High Speed Fuses. Section Contents Page

High Speed Fuses. Section Contents Page Section Contents Page General pplications.......................1-13 North merican fuses & accessories...........1-11 DFJ - High speed Class J fuse.................. 15 Square ody fuses & accessories............

More information

fuses fuse holders CYLINDRICAL

fuses fuse holders CYLINDRICAL fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A Bussmann LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt 601-2000A Dimensional Data All other lerances (± 0.02) 0.63" (± 0.03) All Slots and Holes 10.75" (± 0.09) 8.63" (± 0.09) 6.75" 5.75" 601A 800A

More information

NEOZED D0 fuse-links gg 400/440VAC

NEOZED D0 fuse-links gg 400/440VAC NEOZED D0 fuse-links gg 400/440VAC LOW VOLTAGE IEC FUSES DIN LV FUSE-LINKS D0 FEATURES & BENEFITS The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non

More information

Red Spot Fuse Holders

Red Spot Fuse Holders Finger-safe Fuse Holders for BS88 HRC Industrial Fuses Description A range of CSA certified IP20 finger-safe fuse holders for BS88 HRC industrial fuses in rating up to 400A. Catalog Symbol RS(AMP)(Connection

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead , am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV. DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

Drive, Fuse & Circuit Breaker Ratings

Drive, Fuse & Circuit Breaker Ratings Fuses 1, Fuse & Breaker s The tables on the following pages provide drive ratings (including continuous, 1 minute and 3 second) and recommended AC line input fuse and circuit breaker information. Both

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A DISTRIBUTION SOLUTIONS Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A Continuous protection and reliable operation Proven design and compliance with newest fuses standards Compatibility with other ABB

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes March 2016 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail 2011/65/EU Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the

More information

Big performance in a small package

Big performance in a small package Series usible & Non-fusible 100 400A Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or usible Which is Best or Your Application? Application Data Typical Control Switch

More information

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm Supersedes October 2015 BUSSMANN SERIES UL Class CC, CF (CUBEFuse ), midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-pole Class CC, Midget, 10x38mm Description and

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Ferrule fuses. High Speed Fuses

Ferrule fuses. High Speed Fuses Ferrule fuses Table of Contents Basic Catalog Amp Number Volts Range Page FWA 150 5-0 19-193 FWX 50 1-50 19-195 FWH 500 0.5-30 19-199 FWC 00-3 00-01 FWP 90V/700 1-100 0-05 FWK 750 5-0 0-07 FWJ 1000 0-30

More information

FUSES. Safety through quality

FUSES. Safety through quality Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

NH-Fuse system Low voltage

NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information